The EAP can be ceiling-mounted or wall-mounted. Choose a mounting method according to your needs. Follow the steps below for the appropriate installation.

M3×20 Self-tapping Screws (Qty.4) M3×28 Plastic Wall Anchors (Qty.4)
Wireless Access Point
If your Ethernet cable feeds through the wall, you can position the mounting bracket below the cable hole. Mark four positions for the screw holes and then drill four 6 mm diameter holes at the marked positions.
Setup with videos Visit https://www.tp-link.com/support/setup-video/ or scan the QR code to search for the setup video of your product model.
Wing Nuts (Qty.4) Washers (Qty.4) M3×30 Pan-head Screws (Qty.4)
Insert the plastic wall anchors into the 6 mm diameter holes.

Remove the ceiling tile.
2 Place the mounting bracket in the center of the ceiling tile. Mark four positions for the screw holes and a position for the Ethernet cable hole. Drill four 4 mm diameter holes for the screws and a 25 mm diameter hole for the Ethernet cable at the marked positions.

Secure the mounting bracket to the wall by driving the self-tapping screws into the anchors. Make sure that the shoulders of the mounting bracket are on the outside.
On: Working normally/Initializing. Off: Working abnormally/Power off/LED is turned off.
Flashing:
Initialization: The LED flashes twice after initialization is completed. Upgrade: The LED flashes once per second while upgrading.
Reset: The LED flashes quickly during the reset. The EAP will then reboot.
Locate: When the Locate feature is activated in the Omada controller, the LED flashes quickly to locate and identify the device. The LED will flash for 10 minutes, or you can disable the feature manually to stop it flashing.
Secure the mounting bracket to the ceiling tile using four M3x30 pan-head screws, washers and wing nuts, as shown on the left.

Connect the Ethernet cable to the Ethernet port on the EAP.
Feed the Ethernet cable through the hole and set the ceiling tile back into place.
With the device powered on, press and hold the button for about 5 seconds until the LED flashes quickly . Then release the button. The device will restore to factory default settings.
The port is used to connect to a router or a switch to transmit data, or to a PSE (Power Sourcing Equipment), such as a PoE switch, for both data transmission and Power over Ethernet (PoE) through Ethernet cable. The port supports transmission speed of 10/100/1000/2500 Mbps for EAP660 HD and 10/100/1000 Mbps for EAP610 / EAP620 HD.
Attach the EAP to the mounting bracket, then rotate the EAP until it locks into place, as shown on the left.
Connect the Ethernet cable to the Ethernet port. Attach the EAP to the mounting bracket, then rotate the EAP until it locks into place, as shown on the left.
Plug one end of the provided power adapter to this port and the other end to a standard electrical wall outlet to power the EAP. Power Port: 12V 2A (for EAP660 HD) | 12V 1A (for EAP610 / EAP620 HD)
LED Indicator

Option2: Controller Mode
The EAP can be powered via a power adapter or a PSE device (such as a PoE switch).
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Software Controller, Omada Hardware Controller or Omada Cloud-Based Controller.


PoE Switch (Compliant with 802.3at)
Connect an Ethernet cable from the PoE switch (compliant with 802.3at) to the Ethernet port.
Plug one end of the provided power adapter into the power port of the EAP and the other end to a standard electrical wall outlet.
Before managing the devices via Omada Cloud-Based Controller, make sure they can access the internet.
A DHCP server (typically a router with DHCP function enabled) is required to assign IP addresses to the EAPs and clients in your local network.
The EAP supports two configuring options:
To configure and manage EAPs singly (usually suitable for a small network with a few EAPs), Standalone Mode is recommended. Please refer to Option 1.
To configure and manage EAPs in batch, Controller Mode is recommended. Please refer to Option 2.
After installing Omada Software Controller, you can remotely access the controller through Omada Cloud Portal. Follow the steps below.

With Omada App, you can also manage your Omada Cloud-Based Controller.
Scan for Omada App Download Omada App
With Omada App, you can also manage your Omada Software Controller at a local site and remote site. Note that Omada Software Controller needs to be kept running when using Omada App.
For the detailed configurations, refer to the User Guide of the controller and EAPs. The guides can be found on the download center of our official website: https://www.tp-link.com/support/download/
Scan for Omada App Download Omada App
To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community.
Scan for Omada App Download Omada App
For technical support, the user guide and other information, please visit https://www.tp-link.com/support or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome to email techwriter@tp-link.com.cn.
a. Connect your mobile device to the EAP by using the default SSID (format:
TP-Link_2.4GHz/5GHz_XXXXXX) printed on the label at the bottom of the product.
The Omada App is designed to help you quickly configure the common settings. If you want to configure advanced settings, log in to the web page of your EAP or the controller.
b. Launch Omada App and go to Local Access, tap the + button on the upper-right corner to add
the controller. Then you can further configure the controller.
Keep the device away from water, fire, humidity or hot environments. Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us. Do not use the device where wireless devices are not allowed. Do not use damaged charger or USB cable to charge the device. Do not use any other chargers than those recommended. Adapter shall be installed near the equipment and shall be easily accessible.
Via a Web Browser
a. Make sure Cloud Access is enabled on your controller and your controller has been bound with
your TP-Link ID.
b. Launch Omada App and log in with your TP-Link ID. Then go to Cloud Access. A list of
controllers that have been bound with your TP-Link ID will appear. Then you can further configure the controller.
©2021 TP-Link 7106509200 REV1.1.1
The products of TP-Link partly contain software code developed by third parties, including software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (https://www.tp-link.com/en/support/gpl/). The respective programs are distributed WITHOUT ANY WARRANTY and are subject to the copyrights of one or more authors. For details, see the GPL Code and other terms of the GPL.
Via Omada Hardware Controller (OC200/OC300)
Omada Hardware Controller (OC200/OC300), which is pre-installed with Omada Software Controller, is a good alternative if you have no spare PC to keep running Omada Software Controller in the network. It needs to be purchased additionally. For more details, refer to the Installation Guide of OC200/OC300.
To configure other EAPs, connect your device to the EAP by the coresponding default SSID and repeat the steps listed above. You can configure some basic functions in Standalone Mode. If you want to configure advanced functions, use Controller Mode.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.