BATTERY SYSTEM HyTRON ™ 140 HyTRON ™ 100 HyTRON ™ 50 OWNER’S MANUAL ®.
TABLE OF CONTENTS IMPORTAN T .................................................................................... 2 INTRODUCT ION .............................................................................. 3 FEATURE S ..............................
IMPORTANT The InterActive 2000 HyTRON battery represents the latest in video battery technology. Nickel Metal Hydrid e (NiMH) is similar to NiCad batteries in most characteristics. However, NiMH has more sen sitive charging and discharging parameters and requires a longer charge time for optimum performance.
INTRODUCTION The development of the new InterA ctive 2000 HyTRON battery system has been made possible by recent advancements in a cell technology originally designed for the mobile computing indus try . These nickel metal hydride cells provide the highest energy density cell available.
FEATURES 1. Microprocessor Fuel Compu ter - Accurately monitors the energy put into and taken out of the battery. This data is processed with sophisticated programs that take into account battery age, self discharge, charge/discharge rate , cell imbalance and previously experienced charge/discharge cycles.
6. Impac ® Case design - The computer designed high impact case eliminates conventional stress points. This feature protects the cells from impact that would damage or destroy conventional batteries. 7. Gold Mount ® Interface - The solid metal mounting studs assure a smooth, precise mounting for the life of the battery.
HIGH VOLTAGE DESIGN Virtually all cameras/camcorders will indicate a low voltage warning or cease to operate at about 11 volts. Unfortunately, a 12 volt battery must be discharged to 10 volts for full discharge.
CHARGING WITH LOGIC SERIES INTERACTIVE CHARGERS Charge this battery fully before using. Allow the battery to reach a steady green (LifeSaver ® ) mode before using. Charging is automatic on all Logic Series InterActive chargers. The flashing red and green lights indicate the charger and battery are establishing communications.
OVER-DISCHARGED BATTERIES Warning: The Hy TRON battery has specialized circuits which ty pically will not allow a battery to overdischarge during extended storage (more than 90 days). However , if the battery is left on a load, such as a light, and allowed to discharge to 0 volts, the battery can be irreversibly damaged.
The HyTRON features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increments as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach. No special adapters or set up is required.
-The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers (15, 30, 45, or 60) indicate remaining minutes under current load.
If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should ty pically occur during normal equipment operation.
PREVENTATIVE MAINTENANCE The HyTRON battery incorporates unique battery management features. Together with Anton/Bauer diagnostic accessories, an effective preventative maintenance program can easily be created to optimize the return on battery investment and gr eatly simplify battery management operations.
GUIDELINES FOR OPTIMUM PERFORMANCE AND MAXIMUM LIFE 1. Keep batteries cool or at room temperatures whenever possible. Sustained elevated temperatures are the primary reason for premature failure of NiMH batteries: a. Charging - Charge batteries at room temperature.
5. Routine use of a battery at discharge rates greater than the battery rating (e.g. >50w for Hy tron 50) can reduce overall service life. Always select the proper size battery for y our application. 6. Discharging the battery for di agnostic purposes should only be performed on an occasional basis (once every 6-8 weeks at most).
SERVICE In the unlikely event a Hy TRON battery fails to deliver acceptable performance, it must be returned to the Anton/Baue r Customer Support Department, the only facility qualified and equipped to servi ce the InterActive 2000 HyTRON batteries and calibrate the electronic components and sensors.
Limited Warranty This warranty for the battery product specified in this document (“Product”) is given by Anton/Bauer, Inc. (“Anton/Bauer”), 14 Progress Drive, Shelton, Connecticut 06484.
The liability of Anton/Bauer hereunder is expressly limited to a claim for repair or replacement of the Product or as otherwise stated herein at Anton/Bauer’s sole discretion.
The power behind the best cameras capturing the best images in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and parallelogram desi.
An important point after buying a device Anton/Bauer HyTRON 50 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Anton/Bauer HyTRON 50 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Anton/Bauer HyTRON 50 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Anton/Bauer HyTRON 50 you will learn all the available features of the product, as well as information on its operation. The information that you get Anton/Bauer HyTRON 50 will certainly help you make a decision on the purchase.
If you already are a holder of Anton/Bauer HyTRON 50, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Anton/Bauer HyTRON 50.
However, one of the most important roles played by the user manual is to help in solving problems with Anton/Bauer HyTRON 50. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Anton/Bauer HyTRON 50 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center