Bx2000 has been designed to provide greater flexibility to the consumer using Off-Peak electricity for Water heating. It provides the facility to Boost your Hot water at any time and to ensure you are automatically connected to the Off-Peak supply whenever it is available.

INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IET WIRING REGULATIONS.

The BX2000 should be mounted on a standard conduit box or directly onto the wall. It should NOT be mounted on an unearthed metal surface. The BX2000 should be connected to the incoming supplies using 3 core cable with a minimum conductor size of 1.5 . Heat resisting flexible cords should be used to make connection to the 2 mm immersion heater(s).

Means of disconnection from the 24 Hour and Off Peak supplies having at least 3mm contact separation in both poles must be incorporated in the fixed wiring (This is usually provided in the consumer unit). Both the Off Peak and 24 Hour supplies must be on the same phase. Both the Off Peak and 24 Hour supplies should be protected by a 15 amp HRC fuse or, preferably a 16 amp MCB. In some cases immersion heater failure can damage the BX2000. Installation of a 100 mA RCD will provide additional protection for the unit. If the BX2000 is to be connected to a ring main then the spur feeding the controller should be protected in the same way.

Page 2 of the Secure Electronic Boost Control (BX2000) user manual — BX2000 Installation Instructions
Page 2 · click to enlarge
Page 2

Mounting The BX2000 should be removed from the mounting box by unscrewing the 2 captive screws securing the unit.

Secure Electronic Boost Control (BX2000) — BX2000 Installation Instructions diagram (page 2)
Fig. 2 · BX2000 Installation Instructions

Conduit Box Mounting Use either the 2 holes marked

'A' (see diagram) to secure to a single gang box, or the two holes marked 'C' for a double gang box. Cable entry is through the cut-out between the 2 fixing holes 'A'.

Use the two holes marked 'B' (see diagram). Cable entry is through the most appropriate cut-out.

REMOVE THE APPROPRIATE CABLE ENTRY CUT-OUTS BEFORE FIXING THE BOX, WHERE POSSIBLE DRILL THE BOX TO PROVIDE A CLOSE FITTING ENTRY FOR CABLES AND HEAT-RESISTANT FLEXIBLE CORDS. TAKE CARE TO REMOVE SHARP EDGES .

Connections - Single Immersion Heater

2 Use a three-core cable with a minimum conductor size 1.5mm to connect the unit to the supply. Connect the incoming wires to the terminal block as follows;

TERMINAL 1 - Link to Terminal 7

TERMINAL 2 - Link to Terminal 8

TERMINAL 3 - LIVE 24 Hour On Peak (Boost) supply in

TERMINAL 4 - NEUTRAL 24 Hour On Peak (Boost) supply in TERMINAL 5 - LIVE out to immersion heater

TERMINAL 6 - NEUTRAL to immersion heater

TERMINAL 7 - Linked to Terminal 1

TERMINAL 8 - Linked to Terminal 2

TERMINAL 9 - LIVE Off Peak supply in

TERMINAL 10 - Neutral Off Peak supply in

Clamp all surface wiring adjacent to the box or use trunking where appropriate. Secure the heat resistant flexible cords from the immersion heaters using the cable clamp in the box.

Surface Mounting

Page 3 of the Secure Electronic Boost Control (BX2000) user manual — BX2000 Installation Instructions
Page 3 · click to enlarge
Page 3

Connections - Dual Or Twin Immersion Heaters

Use a three-core cable with a minimum conductor size of 1.5 to connect the unit 2 mm to the supply. Connect the incoming wires to the terminal block as follows;

TERMINAL 1 - Do not use TERMINAL 2 - Do not use

TERMINAL 3 - LIVE 24 Hour On Peak (Boost) supply in TERMINAL 4 - NEUTRAL 24 Hour On Peak (Boost) supply in

TERMINAL 6 - NEUTRAL to top or Boost immersion heater TERMINAL 5 - LIVE out to top or Boost immersion heater

TERMINAL 7 - LIVE out to bottom or Off Peak immersion heater TERMINAL 8 - NEUTRAL to bottom or Off Peak immersion heater

TERMINAL 9 - LIVE Off Peak supply in

TERMINAL 10 - NEUTRAL Off Peak supply in

Clamp all surface wiring adjacent to the box or use trunking where appropriate. Secure the heat resistant flexible cords from the immersion heaters using the cable clamp in the box.

Secure Electronic Boost Control (BX2000) — BX2000 Installation Instructions diagram (page 3)
Fig. 3 · BX2000 Installation Instructions
Secure Electronic Boost Control (BX2000) — BX2000 Installation Instructions diagram (page 3)
Fig. 4 · BX2000 Installation Instructions

Wiring diagram for Hot water cylinders with single immersion heater.

Wiring diagram for Hot water cylinders

with dual or twin immersion heater.

When wiring is complete ensure that all terminal screws, including the earth terminal screws are securely tightened to achieve a minimum torque of .75Nm.

To assemble the controller to its mounting box first push the connectors numbered 1 - 10 into the corresponding numbered terminal as shown (see diagram on page 2) Carefully offer the controller to the box and secure with the fixing screws, ensuring the wiring does not become damaged.

Switch on the mains supply, put the rocker switches in the ON position.

Bx2000 Internal Connections · Completing The Installation

Page 4 of the Secure Electronic Boost Control (BX2000) user manual — NP0080093000
Page 4 · click to enlarge
Page 4

Purpose of Control Electronic immersion heater boost control

Contact Rating 13A 230V AC (Suitable for immersion heater up to 3kW)

Supply 230V AC 50Hz only Contact Type Full disconnection on Double pole isolator

Protection Class l Control Action Type 1B,Q/R (R-Off-Peak Relay, Q-Boost Relay)

Operating Time Limitation 1 or 2 Hour Boost

Software Class Class A

Dimensions 170mm x 115mm x 62mm

Case Material Thermoplastic, flame retardant

Ball Pressure Test Temperature 75°C Mounting independently wall mounted

Environmental Impulse Voltage Rating Cat ll 2500V

Pollution Degree Degree 2 Operating Temperature

Range 0°C to +35°C

Compliance Design Standard EN 60730-2-7, BS EN 60730-1, BS EN 60720-2-7

Secure Meters (UK) Ltd Secure House, Lulworth Close,

NP0080093000

Chandlers Ford, Eastleigh, SO53 3TL, UK

t: +44 1962 840048 f: +44 1962 841046

www.securemeters.com

Part Number P80093 Issue 13

Show 4 more labels / short text on this page
Specification · Electrical · Mechanical · Enclosure Protection Ip30
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Secure Electronic Boost Control (BX2000)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Secure Electronic Boost Control (BX2000)

Be the first to ask — other owners or our team will answer.

Original document

Secure Electronic Boost Control (BX2000) manual PDF

4 pages·1.8 MB·Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…