EN
Official user manual

Memmert Pump Module (PM/PMP)

48 pages·1.9 MB·Pump·PDF·ENDEFRITNLJA
Memmert Pump Module (PM/PMP)
Table of Contents 9 sections Manual · Contents · About this manual · 1. Safety regulations · … ShowHide
Page 1 of the Memmert Pump Module (PM/PMP) user manual — Pump module PM - PMP
Page 1 · click to enlarge
Page 1
Memmert Pump Module (PM/PMP) — Manual diagram (page 1)
Fig. 1 · Manual
Memmert Pump Module (PM/PMP) — Manual diagram (page 1)
Fig. 2 · Manual

PM - PMP

Memmert Pump Module (PM/PMP) — PM - PMP diagram (page 1)
Fig. 3

Manual

Pump module PM - PMP

MADE IN GERMANY.

www.memmert.com

Page 2 of the Memmert Pump Module (PM/PMP) user manual — Manual
Page 2 · click to enlarge
Page 2

Manufacturer and customer service MEMMERT GmbH + Co. KG Willi-Memmert Strasse 90-96 91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585 E-mail: sales@memmert.com Internet: www.memmert.com Customer service: Service hotline: +49 (0)9171 9792 911 Service fax: +49 (0)9171 9792 979 E-mail: service@memmert.com When calling for service enquiries, please state the appliance number given on the nameplate Shipping address for repairs: Memmert GmbH + Co. KG Customer service Willi-Memmert Str. 90-96 91186 Büchenbach Germany Please contact our customer service department before sending appliances for repair or before returning equipment, or the shipment may be refused.

© 2019 MEMMERT GmbH + Co. KG D39489 I Date 12/2019 Subject to change without notice

Page 3 of the Memmert Pump Module (PM/PMP) user manual — Manual
Page 3 · click to enlarge
Page 3
Page 3 of the Memmert Pump Module (PM/PMP) user manual — Manual
Page 5 of the Memmert Pump Module (PM/PMP) user manual — ► The operating manual for the MEMMERT vacuum oven VO
Page 5 · click to enlarge
Page 5

About this manual

Purpose and target audience This manual, together with the operating manual for the MEMMERT vacuum oven, describes how to use and put into operation the MEMMERT pump module. Pump modules can be purchased with or without a pre-installed vacuum pump. The manual contains the original maintenance and operating manual for the membrane vacu- um pump, which may have been installed, from the company KNF.

The pump module may only be used in combination with the MEMMERT vacuum oven VO or VOcool. All information in terms of safety instructions, assembly, function, transport, putting into operation, troubleshooting, maintenance and decommissioning/disposal can be found in the operating manual for the vacuum oven VO. This manual is intended for use by trained personnel of the owner, who have the task of oper- ating and/or maintaining the respective appliance. If you are asked to work on the appliance, read this manual carefully before starting. Familiarise yourself with the safety regulations. Only perform work that is described in this manual. If there is something you do not understand, or certain information is missing, ask

your manager or contact the manufacturer. Do not do anything without authorisation.

Other documents to be observed as applicable:

► The operating manual for the MEMMERT vacuum oven VO

►The original maintenance and operating manual for the vacuum pump from KNF

Storage and resale This operating manual belongs with the appliance and should always be stored where per- sons working on the appliance have access to it. It is the owner’s responsibility to ensure that persons who are working on or are going to work on the appliance know where to find the operating manual. We recommend that it is always stored in a protected location close to the appliance. Make sure that the operating manual is not damaged by heat or humidity. If the appliance is resold or transported and then set up again at a different location, the operating manual must remain with it. The current version of this operating manual in PDF format is also available for download from http://www.memmert.com/en/service/downloads/user-manual/

Page 6 of the Memmert Pump Module (PM/PMP) user manual — WARNING
Page 6 · click to enlarge
Page 6

Safety regulations

1. Safety regulations

1.1 Product safety and dangers The appliances described in this manual are technically sophisticated, manufactured using high-quality materials and subject to many hours of testing in the factory. They reflect the state of the art and comply with recognised technical safety regulations. However, there are still risks involved, even when the appliances are used as intended. These are described below.

WARNING

After removing covers, live parts may be exposed. Touching these can lead to an electric shock. Disconnect the mains plug before removing any covers. Work on the electrical system must only be performed by qualified electricians.

WARNING

Toxic gases or vapours may be produced in certain applications. These can escape from the vacuum pump into the room. This can injure people nearby. The appliance may only be used for such applications if a suction is attached to the vacuum pump used, which reliably keeps toxic gases or vapours away from people. Ob- serve the respective national regulations for occupational safety and environmen- tal protection.

Memmert Pump Module (PM/PMP) — WARNING diagram (page 6)
Fig. 4

The operating manual of the MEMMERT vacuum oven contains important informa- tion and instructions how to use the pump module. Follow all possible information from the related operating manual of the vacuum oven exactly.

Page 7 of the Memmert Pump Module (PM/PMP) user manual — Safety regulations
Page 7 · click to enlarge
Page 7

Safety regulations

1.2 Intended use The appliance may only be used to accommodate and control a vacuum pump by means of a MEMMERT vacuum oven VO29, VO49 or VO101. Any other use is improper and may result in hazards and damage.

1.3 Changes and alterations No unauthorised changes or alterations may be made to the appliance. No parts may be add- ed or inserted which have not been approved by the manufacturer. Unauthorised changes or alterations result in the CE declaration of conformity losing its validi- ty, and the appliance may no longer be operated. The manufacturer is not liable for any damage, danger or injuries that result from unauthor- ised changes or alterations, or from non-compliance with the provisions in this manual.

1.4 Requirements of the operating personnel The appliance may only be operated and maintained by persons who are of legal age and have been instructed accordingly. Personnel who are to be trained, instructed or who are un- dergoing general training may only work with the appliance under the continuous supervision of an experienced person. Repairs may only be performed by qualified specialists. The provisions in the operating and installation manual from KNF also need to be observed.

1.5 Behaviour in case of malfunctions and irregularities The appliance may only be used in a flawless condition. If you as the operator notice irregular- ities, malfunctions or damage, immediately take the appliance out of service and inform your superior.

1.6 Switching off the appliance in an emergency Press the main switch on the pump module. This disconnects the appliance from the power supply at all poles.

Memmert Pump Module (PM/PMP) — Safety regulations diagram (page 7)
Fig. 5 · Safety regulations
Page 8 of the Memmert Pump Module (PM/PMP) user manual — ► It cannot come into contact with any
Page 8 · click to enlarge
Page 8

Putting into operation

2. Putting into operation

When operating the appliance for the first time, do not leave it unattended until it has reached a steady state.

2.1 Connecting the vacuum pump Connect the vacuum pump’s 230 V plug with earthing contact to the internal socket in the pump module.

Memmert Pump Module (PM/PMP) — Putting into operation diagram (page 8)
Fig. 6 · Putting into operation

2.2 Connecting the appliance

NOTICE

For connection, please observe the national regulations. Observe the connection and power ratings (see nameplate and technical data).

Memmert Pump Module (PM/PMP) — NOTICE diagram (page 8)
Fig. 7

Make sure to establish a safe PE conductor connection. Place the power cable so that

► It is easily accessible at all times and can

be pulled out quickly, for example in case of a malfunction or emergency; ►It does not represent a trip hazard;

► It cannot come into contact with any

hot parts.

Page 9 of the Memmert Pump Module (PM/PMP) user manual — Putting into operation
Page 9 · click to enlarge
Page 9

Putting into operation

2.3 Connecting the vacuum pump to the VO The connection for the signal lead (left) and the connection for the vacuum hose (right) can be found at the rear of the PM. Connect the vacuum oven and the pump module to the signal lead and the vac- uum hose as described in the operating manual for the MEMMERT vacuum oven.

Memmert Pump Module (PM/PMP) — Putting into operation diagram (page 9)
Fig. 8 · Putting into operation
Memmert Pump Module (PM/PMP) — Putting into operation diagram (page 9)
Fig. 9 · Putting into operation

2.4 Switching on 1. Press the main switch for the vacuum pump.

Memmert Pump Module (PM/PMP) — Putting into operation diagram (page 9)
Fig. 10 · Putting into operation
2. Press the main switch for the pump module.
Memmert Pump Module (PM/PMP) — Putting into operation diagram (page 9)
Fig. 11 · Putting into operation
Page 10 of the Memmert Pump Module (PM/PMP) user manual — ► E07534 spare parts kit for membrane
Page 10 · click to enlarge
Page 10

Technical data

3. Technical data

Appliance size2949101 Appliance width D [mm]550550710 Appliance height E [mm]600680760 Appliance depth F [mm]400480550 Depth of door lock [mm]38 Weight without/with pump [kg]25 / 3330 / 3841 / 49 Power [W]*140 Current consumption [A]*1,9

*All other technical data can be found in the operating and installation manual for the KNF pump which follows

4. Spare parts and service

In the event of a malfunction or if the pre-installed membrane vacuum pump requires mainte- nance or service work, contact the Customer Service department at Memmert. The spare parts required for complete maintenance of the pump head are available from Memmert under the following order number:

► E07534 spare parts kit for membrane

5. Maintenance and cleaning

Depending on the customer process, condensate may accumulate in the collection con- tainer of the pump module. No condensate can be sucked in by the pump. Check and empty the container regularly.

5.1 Emptying the collection container 1. Unscrew and remove the ducts from the collection container. 2. Remove the collection container from the holder and empty it. 3. Insert the collection container into the holder and attach the ducts.

Memmert Pump Module (PM/PMP) — ► E07534 spare parts kit for membrane diagram (page 10)
Fig. 12 · ► E07534 spare parts kit for membrane
Page 11 of the Memmert Pump Module (PM/PMP) user manual — Operating and installation information
Page 11 · click to enlarge
Page 11

Operating and installation information

6. Operating and installation information

Information about the assembly and functionality of the pre-installed KNF vacuum pump N950.50 KNE-W can be found in the manufacturer’s original operating manual (provided).

Page 12 of the Memmert Pump Module (PM/PMP) user manual — KNF 125530-316634 06/18
Page 12 · click to enlarge
Page 12

Operating and installation information

KNF 125530-316634 06/18

LAB

PJ25481-950.50.18 TRANSLATION OF ORIGINAL INSTALLATION INSTRUCTIONS ENGLISH

DIAPHRAGM PUMP

Memmert Pump Module (PM/PMP) — KNF 125530-316634 06/18 diagram (page 12)
Fig. 13
Page 13 of the Memmert Pump Module (PM/PMP) user manual — 4. Technical Data.......................................................................... 8
Page 13 · click to enlarge
Page 13

KNF Neuberger GmbH Alter Weg 3 79112 Freiburg

Contents Page

1. About this document................................................................. 3

Phone +49-(0)7664-5909-0 Fax +49-(0)7664-5909-99

2. Use 4

3. Safety........................................................................................ 6

E-mail[email protected] www.knf.de

4. Technical Data 8

5. Design and function................................................................ 10

6. Installation and connection..................................................... 11

7. Operation................................................................................ 15

8. Servicing................................................................................. 20

9. Troubleshooting...................................................................... 28

10. Returns ................................................................................. 300

11. Health and safety clearance and decontamination form ...... 311

Germany

Page 14 of the Memmert Pump Module (PM/PMP) user manual — WARNING
Page 14 · click to enlarge
Page 14

Diaphragm pump PJ25481-950.50.18 About this document

1. About this document

1.1. Using the Installation Instructions

The Installation Instructions are part of the pump.

Carefully study the Installation Instructions before using the

pump.

Always keep the Installation Instructions handy in the work

area.

Pass on the Installation Instructions to the next owner.

1.2. Symbols and markings

A danger is located here.

Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. Warning, indicates the danger level.

WARNING

Measures for avoiding the danger and its conse-

quences are specified here.

Signal word Meaning Consequences if not observed DANGER warns of immedi- ate danger

Death or serious injuries and/or serious damage are the conse- quence. WARNING warns of possible danger

Death or serious injuries and/or serious damage are possible. CAUTION warns of a possi- bly dangerous situation

Minor injuries or damage are possible.

Tab. 1

Other information and symbols

An activity to be carried out (a step) is specified here.

1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow.

This symbol refers to important information.

Original-Installation Instructions, english, KNF 125530-316634 06/18 3

Page 15 of the Memmert Pump Module (PM/PMP) user manual — 2.1. Proper use
Page 15 · click to enlarge
Page 15

Use Diaphragm pump PJ25481-950.50.18

2. Use

2.1. Proper use

The pumps are exclusively intended for transferring gases and va- pors.

Only install and operate the pumps under the operating parameters and conditions described in Chapter 4. Technical Data.

Make sure that the installation location is dry and the pump is pro- tected against rain, splash, hose and drip water as well as other pollutions.

The gas-tightness of the connections between the application pipes and the pump (or the pump connection) must be checked regularly; with leaky connections, there is a danger that hazardous gases or vapors may escape from the pump system.

Requirements for transferred medium

Before using a medium, check whether the medium can be trans- ferred danger-free in the specific application case.

Before using a medium, check the compatibility of the materials of the pump head, diaphragm and valves with the medium.

Only transfer gases which remain stable under the pressures and temperatures occurring in the pump.

Laboratory equipment or additional components connected to a vacuum pump system have to be suitable for use with the pneu- matic capabilities of the pump. (see Chapter 4. Technical Data).

Show 4 more labels / short text on this page
Owner’s responsibility · Operating parameter and · conditions · Accessories
Page 16 of the Memmert Pump Module (PM/PMP) user manual — 2.2. Improper use
Page 16 · click to enlarge
Page 16

Diaphragm pump PJ25481-950.50.18 Use

2.2. Improper use

The pumps may not be operated in an explosive atmosphere.

The pumps are not suitable for transferring dusts.

The pumps are not suitable for transferring liquids.

The pumps are not suitable for transferring aerosol.

The pumps are not suitable for transferring biological and microbio- logical substances.

The pumps are not suitable for transferring fuel.

The pumps are not suitable for transferring explosive and combus- tible materials.

The pumps are not suitable for transferring fibers.

The pumps are not suitable for transferring oxidizing agent.

The pumps are not suitable for transferring foodstuffs.

The pumps must not be used to create vacuum and overpressure simultaneously.

Pumps designed to create either a vacuum or an overpressure must not be used for these two purposes simultaneously.

An overpressure must not be applied to the suction side of the pump.

Page 17 of the Memmert Pump Module (PM/PMP) user manual — 3. Safety
Page 17 · click to enlarge
Page 17

Safety Diaphragm pump PJ25481-950.50.18

3. Safety

The pumps are built according to the generally recognized rules of the technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during their use which lead to injuries to the user or others, or to damage to the pump or other property.

Only use the pumps when they are in a good technical and proper working order, in accordance with their intended use, observing the safety advice within the Installation Instructions, at all times.

Components connected to the pump must be designed to with- stand the pneumatic performance of the pump.

Take care that safety regulations are observed when connecting the pump to the electricity supply.

Make sure that only trained and instructed personnel or specially trained personnel work on the pumps. This especially applies to assembly, connection and servicing work.

Make sure that the personnel has read and understood the Instal- lation Instructions, and in particular the “Safety” chapter.

Working in a safety

Observe the accident prevention and safety regulations when per- forming any work on the pump and during operation.

Do not expose any part of your body to the vacuum.

Ensure that the pump is separated from the mains and is de-ener- gized.

The pump heads heat up during operation – avoid contact with them.

Make sure that there are no hazards due to flow with open gas connections, noises or hot gases.

Ensure that an EMC-compatible installation of the pump is ensured at all times and that this cannot lead to a hazardous situation.

When transferring dangerous media, observe the safety regula- tions when handling these media.

If the diaphragm ruptures, the transferred medium will mix with the air in the environment. Take all necessary care to prevent this leading to a dangerous situ- ation.

Be aware that the pumps are not designed to be explosion-proof.

Make sure the temperature of the medium is always sufficiently be- low the ignition temperature of the medium, to avoid ignition or ex- plosion. This also applies for unusual operational situations.

Show 4 more labels / short text on this page
Personnel · conscious manner · Handling dangerous media · Handling combustible media
Page 18 of the Memmert Pump Module (PM/PMP) user manual — DIN EN 50581
Page 18 · click to enlarge
Page 18

Diaphragm pump PJ25481-950.50.18 Safety

Hence, make sure the temperature of the medium is sufficiently be- low the ignition temperature of the medium, even when it is com- pressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (Chapter 4).

If necessary, consider any external sources of energy, such as ra- diation, that may add heat to the medium.

In case of doubt, consult the KNF customer service.

Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental pro- tection regulations. Observe the respective national and interna- tional regulations. This especially applies to parts contaminated with toxic substances.

The pumps conform to the Directive 2011/65/EU (RoHS2).

The pumps conform to the safety regulations of the EC Directive 2014/30/EU concerning Electromagnetic Compatibility and the EC Directive 2006/42/EC concerning Machinery.

The following harmonized standards have been used:

DIN EN 61010-1

DIN EN 61326-1 Class A

DIN EN 50581

The pumps correspond to DIN EN 60664-1:

The overvoltage category II

The pollution degree 2

The pump is maintenance-free. But KNF recommends, checking the pump regularly with regard to conspicuous changes in noise and vibrations.

Only have repairs to the pumps carried out by the KNF Customer Service responsible.

Housing with voltage-caring parts may be opened by technical per- sonnel only.

Use only genuine parts from KNF for servicing work.

Use only the original KNF power supply.

Show 4 more labels / short text on this page
Environmental protection · Standards · Customer service and · repairs
Page 19 of the Memmert Pump Module (PM/PMP) user manual — 4. Technical Data
Page 19 · click to enlarge
Page 19

Technical Data Diaphragm pump PJ25481-950.50.18

4. Technical Data

Memmert Pump Module (PM/PMP) — 4. Technical Data diagram (page 19)
Fig. 14 · 4. Technical Data

Assembly Material Diaphragm PTFE coated Valve plates FFPM O-ring FPM (head 1-3) FFPM (head 4) Head plate PPS Intermediate plate PPS

Tab. 2

Memmert Pump Module (PM/PMP) — 4. Technical Data diagram (page 19)
Fig. 15 · 4. Technical Data

Delivery rate at atm. pressure and 5V control voltage [l/min]*

Tab. 3 *Liters in standard state (1013 mbar)

Pump type Value PJ25481-950.50.18 Hose ID 10

Tab. 4

Memmert Pump Module (PM/PMP) — 4. Technical Data diagram (page 19)
Fig. 16 · 4. Technical Data

Parameter Value Automatic voltage selection 100-240 V 50 – 60 Hz Max. current consumption [A] 1.9 Max. power consumption [W] 140 Maximum permitted mains voltage fluctuations

Protection class Motor IP 20 Protection class Pump IP 20

Tab. 5

The pump is supplied by a universal power supply with inte- grated overload protection. They are protected against overheating by a temperature sen- sor on the motor board and equipped with overcurrent protec- tion. If one of these safety functions is triggered, the pump will be shut down and must be manually reset, as follows: Separate pump from mains. Remove the cause(s) of the fault before restarting.

Show 4 more labels / short text on this page
Pump materials · Pneumatic values · Pneumatic Connections · Electrical data
Page 20 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 20 · click to enlarge
Page 20

Diaphragm pump PJ25481-950.50.18 Technical Data

Pump type Value PJ25481-950.50.18 Approx. 7.2 kg

Tab. 6

Parameter Value Permissible ambient tempera- ture

+ 10°C to + 40°C

+ 5°C to + 40°C

Dimensions See Fig. 3, Chapter 6.1 Maximum permissible ambient relative humidity

80% for temperatures up to 31°C, decreasing linearly to 50% at 40°C. Max. altitude of site: [m above sea level]

Tab. 7

Weight · Other parameters · Permissible media tempera- ture

Page 21 of the Memmert Pump Module (PM/PMP) user manual — 5. Design and function
Page 21 · click to enlarge
Page 21

Design and function Diaphragm pump PJ25481-950.50.18

5. Design and function

1 Inlet (suction side)

Memmert Pump Module (PM/PMP) — 5. Design and function diagram (page 21)
Fig. 17 · 5. Design and function

2 Outlet (pressure side)

3 Power switch, removable mains cable

4 Sub-D-plug (motor control)

Fig. 1Design PJ25481-950.50.18
Memmert Pump Module (PM/PMP) — 5. Design and function diagram (page 21)
Fig. 18 · 5. Design and function
Fig. 2Pump head

Diaphragm pumps transfer, compress (depending on pump ver- sion) and evacuate gases and vapors.

The elastic diaphragm (4) is moved up and down by the eccentric (5) and the connection rod (6). In the downward stroke it aspirates the gas to be transferred via the inlet valve (2). In the upward stroke, the diaphragm presses the medium out of the pump head via the outlet valve (1). The transfer chamber (3) is hermetically separated from the pump drive (7) by the diaphragm.

Show 9 more labels / short text on this page
Design · Function Diaphragm Pump · 1 Outlet valve · 2 Inlet valve · 3 Transfer chamber · 4 Diaphragm · 5 Eccentric · 6 Connection rod · 7 Pump drive
Page 22 of the Memmert Pump Module (PM/PMP) user manual — 6.1. Installation of the pump
Page 22 · click to enlarge
Page 22

Diaphragm pump PJ25481-950.50.18 Installation and connection

6. Installation and connection

Only install and operate the pumps under the pneumatic operating parameters and conditions described in Chapter 4, Technical Data.

Observe the safety precautions (see Chapter 3).

6.1. Installation of the pump

Choose a safe location (flat surface) for the pump.

Before installation, store the pump at the installation location to

bring it up to ambient temperature.

See Fig. 3 for mounting dimensions.

Memmert Pump Module (PM/PMP) — 6.1. Installation of the pump diagram (page 22)
Fig. 19 · 6.1. Installation of the pump
Memmert Pump Module (PM/PMP) — 6.1. Installation of the pump diagram (page 22)
Fig. 20 · 6.1. Installation of the pump
Memmert Pump Module (PM/PMP) — 6.1. Installation of the pump diagram (page 22)
Fig. 21 · 6.1. Installation of the pump
Fig. 3Mounting dimensions PJ25481-950.50.18 (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V)

Install the pump so that the motor fan can intake sufficient

cooling air.

Make sure that the installation location is dry and the pump is

protected against rain, splash, hose and drip water as well as other pollutions.

Make sure, that the installation location is accessible for

maintenance and service.

The IP protection class of the pump motor is indicated on the type plate.

Install the pump at the highest point in the system to prevent

condensate from collecting in the pump head.

Protect the pump from dust.

Mounting dimensions · Cooling air supply · Installation location

Page 23 of the Memmert Pump Module (PM/PMP) user manual — WARNING
Page 23 · click to enlarge
Page 23

Installation and connection Diaphragm pump PJ25481-950.50.18

Protect the pump against grease and oils.

Protect the pump from vibrations and jolts.

Personal injury and/or damage to property because of vibration

In conjunction with adjacent components, vibration of the pump may result in crushing and/or damage to these components.

WARNING

Make sure that vibrations of the pump do not re-

sult in hazards associated with adjacent compo- nents.

ter. Foreign matter protection

Protect the pump against contact and intrusion of foreign mat-

Page 24 of the Memmert Pump Module (PM/PMP) user manual — CAUTION
Page 24 · click to enlarge
Page 24

Diaphragm pump PJ25481-950.50.18 Installation and connection

6.2. Electrical connection

Extreme danger from electrical shock

Only have the pump connected by an authorized

specialist. Only have the pump connected when the power

DANGER

supply is disconnected.

When connecting the device to a power source, the relevant

standards, directives, regulations, and technical standards must be observed.

1. Compare the supply data with the data on the motor plate. For maximum operating current of the pump see pump’s type plate.

The voltage must not vary by more than + 10% and – 10% from that shown on the type plate.

2. Insert the mains cable plug into a properly installed shockproof socket.

Ensure sufficient dimensioning of the connection cables.

6.3. Pneumatic connection

Personal injury or damages to property by ejected protective plugs

If the protective plug at the pressure side of the pump hasn’t been removed, it could be ejected be- cause of the overpressure during operation.

CAUTION

Remove the protective plug during the installa-

tion.

Only connect components to the pump which are designed for

the pneumatic data of the pump (see Chapter 4, Technical Data).

If the pump s used as a vacuum pump, safely discharge the

pump exhaust at the pump’s pneumatic outlet.

Connecting pump · Connected components · Pump exhaust

Page 25 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 25 · click to enlarge
Page 25

Installation and connection Diaphragm pump PJ25481-950.50.18

A marking on the pump head shows the direction of flow.

Confusion between suction and pressure sides can lead to breakage of connected components on the suction and pres- sure sides.

1. Remove the protective plugs from the hose connection threads.
2. Connect the suction line and pressure line (see Chapter 4, Tab. 7 for mounting dimensions).
3. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump.

Connecting pump

Page 26 of the Memmert Pump Module (PM/PMP) user manual — WARNING
Page 26 · click to enlarge
Page 26

Diaphragm pump PJ25481-950.50.18 Operation

7. Operation

7.1. Initial start-up

Operational requirements Pump All hoses attached properly.

Fan openings not blocked.

Specifications of the power supply corre- spond with the data on the pump’s type plate.

Ensure that the pump outlet is not closed or constricted.

Tab. 8

7.2. Start up

During or after operation of the pump, some pump parts may be hot.

WARNING

Allow the pump to cool after operation. Take safety precautions against the contact of

hot parts/media.

Injury of the eyes

During excessive approach to the inlet or outlet of the pump, the eyes could be injured by the upcoming vacuum or overpressure.

WARNING

Don’t look into the pump’s inlet or outlet during

the operation.

Only operate the pumps under the operating parameters and

conditions described in Chapter 4. Technical Data.

Make sure the pumps are used properly (see Chapter 2.1).

Make sure the pumps are not used improperly (see Chapter

2.2).

Observe the safety precautions (see Chapter 3).

Page 27 of the Memmert Pump Module (PM/PMP) user manual — 7.3. Switching Pump on/off
Page 27 · click to enlarge
Page 27

Operation Diaphragm pump PJ25481-950.50.18

Hazard of the pump head bursting due to excessive pressure increase

Do not exceed max. permissible operating pres-

WARNING

sure (see Chapter 4. Technical Data. Monitor pressure during operation. If the pressure exceeds the maximum permissi-

ble operating pressure, immediately switch off pump and eliminate fault (see Chapter 9. Trou- bleshooting). Only throttle or regulate the air or gas quantity in

the suction line to prevent the maximum permis- sible operating pressure from being exceeded. If the air or gas quantity in the pressure line is

throttled or regulated, make sure that the maxi- mum permissible operating pressure is not ex- ceeded. Ensure that the pump outlet is not closed or con-

stricted.

Excessive pressure (with all of the related hazards) can be pre- vented by placing a bypass line with a pressure-relief valve be- tween the pressure and suctions sides of the pump. For further information, contact our technical adviser (contact data: see www.knf.com).

With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure.

Automatic starting can cause personal injury and pump damage

When the operation of the pump is interrupted by the thermal switch or the trigging device for PTC sen- sors, the pump will restart automatically after cooling down.

WARNING

Take all necessary care to prevent this leading

to a dangerous situation.

7.3. Switching Pump on/off

The pump may not start up against pressure during switch-on. This also applies in operating following a brief power failure. If a pump starts against pressure, it may block. This activates the overload switch and the pump switches off.

Make sure that normal atmospheric pressure is present in the

lines during switch-on.

Pumpe am Netzschalter einschalten (siehe Fig. 1/3 in Kapitel

5).

Depending on the applied electrical voltage, initialization of the electronics may take up to one second before the pump starts.

Pump standstill · Switching pump on

Page 28 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 28 · click to enlarge
Page 28

Diaphragm pump PJ25481-950.50.18 Operation

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 28)
Fig. 22 · 6. Operating and installation information

Elektrische Anschlüsse / Electrical connection Litzenbelegung / lead assignment

5 Versorgung Gasballastventil Supply gas ballast valve U+GB

6 Eingangssignal Drehzahlregelung Input signal speed control UCtrl

8 Eingangssignal Remote EIN/AUS Input signal Remote ON/OFF URmt

9 Masse Gasballastventil Ground gas ballast valve U-GB

5V Ausgangsspannung U5V / 5V Power supply U5V Ausgangsspannung DC Output voltage range DC [V] 5 ± 0.2

Tab. 9 (part 1)Connection plan motor electronics

External actuation

Page 29 of the Memmert Pump Module (PM/PMP) user manual — [V]
Page 29 · click to enlarge
Page 29

Operation Diaphragm pump PJ25481-950.50.18

Ausgangssignal Drehzahl USpd / Output signal speed USpd

Pulse pro Umdrehung Pulses per revolution [-] 1

Pulstastverhältnis Pulse duty cycle [%] 50 ± 1

PWM-Signal PWM Frequenz PWM frequency [Hz] 50 ± 0.5

Ausgangspegel „high“ Output level „high“ [V] 5 [4.1 … V5V] Ausgangspegel „low“ Output level „low“ [V] 0 [0 … 0.6] Max. Strombelastbarkeit Max. current carrying capacity [mA] 10

Ausgangsimpedanz @ 1 kHz Output impedance @ 1 kHz [kΩ] ≥ 9

Eingangssignal Drehzahlregelung UCtrl / Input signal speed control UCtrl

Steuerspannungsbereich DC Control voltage range DC [V] 0 … 5

Steuerspannungsbeschreibung: min. Pumpe min. Förderleistung max. Pumpe max. Förderleistung Contol voltage description min. pump min. flow max. pump max. flow

min. max.

[V]

Max. Eingangsspannung Max. input voltage [V] 5.5

Schwellenspannung Treshold voltage [mV] 25 ± 0.5

PWM Frequenzbereich PWM frequence range [Hz] 100 [50 … 150] Eingangspegel „high” Input level „high” [V] 5 [4.2 … 5.5] Eingangspegel „low” Input level „low” [V] 0 [0 … 0.9] Tastgradbereich Duty cycle range [%] 0 … 100

Tastgradbeschreibung: min. Pumpe min. Förderleistung max. Pumpe max. Förderleistung Duty cycle description min. pump min. flow max. pump max. flow

min. max.

Eingangsimpedanz @ 1kHz Input impedance @ 1kHz [kΩ] ≥ 12

Tab. 9 (part 2)Connection plan motor electronics
Show 4 more labels / short text on this page
Analog · Analog · PWM-Signal · [%]
Page 30 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 30 · click to enlarge
Page 30

Diaphragm pump PJ25481-950.50.18 Operation

Ausgangssignal Fehler UFlt / Output signal fault UFlt Eingangspegel „high“ Fehler vorhanden Input level „high“ error detected [V] 5 [3.9 … 5.5] Eingangspegel „low“ kein Fehler Input level „low“ no error [V] 0 [0 … 0.9] Max. Strombelastbarkeit Max. current carrying capacity [mA] 10

Ausgangsimpedanz @ 1kHz Output impedance @ 1kHz [kΩ] ≥ 9

Eingangssignal Remote EIN/AUS URmt / Input signal Remote ON/OFF URmt Eingangspegel „high“ Motor EIN Input level „high“ motor ON [V] 5 [3.9 … 5.5] Eingangspegel „low” Motor AUS Input level „low” motor OFF [V] 0 [0 … 0.9] Eingangsimpedanz @ 1 kHz Input impedance @ 1 kHz [kΩ] ≥ 1.8

Versorgung Gasballastventil U+GB / Supply gas ballast valve U+GB Steuerspannung DC Control voltage DC [V] 24 ± 10%

Max. Stromaufnahme Max. current consumption [mA] ≤50

Tab. 9 (part 3)Connection plan motor electronics

Adjusting the flow rate

The flow rate can be varied by an external actuation (Sub-D-plug, see Tab. 9).

The speed of the pump is controlled by a control voltage.

Please contact our KNF customer service for further information.

Remote ON/OFF is through an 9-pin controller connection (Pin 8, see Tab. 9).

To start the motor, Pin 5 must be bridged to the ground of the controller connection.

Please contact our KNF customer service for further information.

Switching off the pump

The life of the diaphragm is prolonged the formation of condensate is avoided. Therefore the following precautions should be taken:

Run the pump for a few minutes to warm it up before handling

saturated or nearly saturated vapors.

KNF recommendsWhen transferring aggressive media, flush

the pump prior to switch off (see Chapter 8.2.1) to increase the service life of the diaphragm.

Switch off pump with power switch (Fig. 1 at Chapter 5).

Restore the system to normal atmospheric pressure (release

pneumatic pressure in pump).

Pull out the pump’s main plug.

Remote ON/OFF · Vapors as media

Page 31 of the Memmert Pump Module (PM/PMP) user manual — CAUTION
Page 31 · click to enlarge
Page 31

Servicing Diaphragm pump PJ25481-950.50.18

8. Servicing

8.1. Servicing schedule

Component Servicing interval Pump - Regular inspection for external damage or leaks Hose connections - Regular inspection for external damage or leaks Diaphragm and valve plates

- Replace when pumping capacity decreases, or sooner Silencer - Change if it is dirty

Tab. 10

8.2. Cleaning

When cleaning, make sure that no liquids enter the inside of the housing.

8.2.1. Flushing pump

Before switching off the pump, flush it with air (or with inert gas

if required for safety reasons) under atmospheric conditions (ambient pressure) for about five minutes.

8.2.2. Cleaning pump

Pump disconnected from mains and de-energized.

Depending on the substance transferred, caustic burns or poisoning are possible.

WARNING

Wear protective clothing if necessary, e.g. pro-

tective gloves. Take the proper steps to clean the pump.

The pump head or motor may be hot even after the pump has been shut off.

CAUTION

Allow the pump to cool off after operation.

Solvent should be used for cleaning only if the head materials

are not corroded (ensure compatibility of the material).

If compressed air is available, blow out the parts.

Requirements

Page 32 of the Memmert Pump Module (PM/PMP) user manual — CAUTION
Page 32 · click to enlarge
Page 32

Diaphragm pump PJ25481-950.50.18 Servicing

8.3. Replacing diaphragm and reed valves

Pump disconnected from mains and de-energized

Pump is clean and free of hazardous materials.

Hoses removed from pump’s pneumatic inlet and outlet.

Spare part/tool Spare parts set according to spare parts list, Chapter 10 Allen key 2-mm (hexagon) Phillips screwdriver No. 2 Allen key 4-mm (hexagon) Felt-tip pen

Tab. 11

Always replace diaphragm and valve plates together to main-

tain the pump performance.

Depending on the substance transferred, caustic burns or poisoning are possible.

WARNING

Wear protective clothing if necessary, e.g. pro-

tective gloves. Flush the pump before replacing the diaphragm

and valve plates (see Chapter 8.2.1).

The pump head or motor may be hot even after the pump has been shut off.

CAUTION

Allow the pump to cool off after operation.

Requirements · Spare parts/tools · Information on procedure

Page 33 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 33 · click to enlarge
Page 33

Servicing Diaphragm pump PJ25481-950.50.18

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 33)
Fig. 23 · 6. Operating and installation information
Fig. 4Exploded drawing PJ25481-950.50.18

1 8x attachment screws (head cover) 2 4x head screws 3 16x attachment screws (head) 4 4x head plates 5 8x O-rings (ø24 x 2) 6 4x intermediate plates 7 4x diaphragms 8 1x connection cover 9 4x attachment screws (connection cover) 10 2x attachment screws (connection .50)

11 2x connection blocks .50 12 2x O-rings (ø7,65 x1,78) 13 2x flat seals 14 2x connection blocks .1.2 15 2x attachment screws (connection .1.2) 16 8x valve plates 17 6x valve plates 18 6x O-rings (ø18,77 x 1,78) 19 6x O-rings (ø10 x 2,5) 20 2x head covers

Removing the pump head

1. Undo the eight screws (Fig. 4/ 1 ) and remove the head covers ( 20 ).
2. Undo the connection cover’s ( 8 ) attachment screws (Fig. 5/ 9 ) and remove the connection cover.
3. Remove the head connection’s ( 11 ) and ( 14 ) screws ( 10 ) and ( 15 ) and remove the head connections.
Page 34 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 34 · click to enlarge
Page 34

Diaphragm pump PJ25481-950.50.18 Servicing

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 34)
Fig. 24 · 6. Operating and installation information
Fig. 5Disassembling the head connections
4. Remove O-rings (Fig. 6/ 12 ) and flat seals ( 13 ).
Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 34)
Fig. 25 · 6. Operating and installation information
Fig. 6Marking the pump
5. Head 1 (Fig. 6/ I ): Use a felt-tip pen to apply a single mark ( M ) to the head plate, intermediate plate, and compressor housing.
6. Head 2 (Fig. 6/ II ): Use a felt-tip pen to apply two marks ( M ) to the head plate, intermediate plate, and compressor housing.
7. Head 3 (Fig. 6/ III ): Use a felt-tip pen to apply three marks ( M ) to the head plate, intermediate plate, and compressor housing.
Page 35 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 35 · click to enlarge
Page 35

Servicing Diaphragm pump PJ25481-950.50.18

8. Head 4 (Fig. 6/ IIII ): Use a felt-tip pen to apply four marks ( M ) to the head plate, intermediate plate, and compressor housing.

During re-assembly, refer to the marks on the individual heads to ensure that the parts are properly re-assembled.

9. Undo the 16 attachment screws (Fig. 4/ 3 ) on the heads ( 1 to 4 ) and remove the heads ( 1 and 2 as well as 3 and 4 ).
10. Pull apart heads 1 (Fig. 7/ I ) and 2 ( II ) and heads 3 ( III ) and 4 ( IIII ) and remove O-rings ( 19 ).
Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 35)
Fig. 26 · 6. Operating and installation information
Fig. 7Removing the o-rings
11. On all four heads, undo the head screw (Fig. 8/ 2 ) in the head plate ( 4 ) and remove head plate from the intermediate plate ( 6 ).
Page 36 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 36 · click to enlarge
Page 36

Diaphragm pump PJ25481-950.50.18 Servicing

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 36)
Fig. 27 · 6. Operating and installation information
Fig. 8Exploded drawing of pump heads 1 and 2

Replacing the diaphragms and valve plates

1. Manually remove the four diaphragms (Fig. 9/ 7 ) by turning them in the counterclockwise direction.

Use caution to prevent the diaphragm spacers (21) located be- tween the diaphragm and the connecting rod from falling into the pump housing. The diaphragm and the connecting rod from falling into the housing. The diaphragm spacers (21) must be installed in the same quantity as before in order to ensure the pump’s pneumatic performance.

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 36)
Fig. 28 · 6. Operating and installation information
Fig. 9Replacing diaphragm
Page 37 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 37 · click to enlarge
Page 37

Servicing Diaphragm pump PJ25481-950.50.18

2. Remove from the intermediate plates (Fig. 8/ 6 ) the valve plates ( 16 ) and ( 17 ) and the O-rings ( 5 ) and ( 18 ).
3. Manually screw the ne diaphragms (Fig. 9/7) into the connecting rod’s threads and tighten to hand tightness.

Before you finally tighten the diaphragms, you are recom- mended to move the diaphragm to the upper dead center.

4. Insert the new valve plates (Fig. 8/ 16 ) and ( 17 ) and the new Orings ( 5 ) and ( 18 ) into the intermediate plates ( 6 ).

The upper and lower sides of the valve plates are identical.

When inserting the O-rings, make sure that they are the correct size and color (head 4: black O-rings).

Install intermediate plates and head cover

1. Place head plate (Fig. 8/ 4 ) onto the intermediate plates ( 6 ), observing the felt-tip pen marks (Fig. 6/ M ).
2. With your hands, carefully and lightly tighten the head plate’s head screw (Fig. 8/ 2 ) on all four heads (tightening torque: 60 Ncm).
Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 37)
Fig. 29 · 6. Operating and installation information

Refer to for arrangement and alignment of disk springs and the screw’s washer. When inserting the O-rings, make sure that they are the correct size and color (head 4: black O-rings).

3. Place three O-rings (Fig. 7/ 19 ) into each of the head connection holes.
4. Press together heads 1 and 2 (Fig. 6/ I and II ) and heads 3 and 4 ( III and IIII ).
Fig. 10Aligning the
5. Place heads 1 and 2 and heads 3 and 4 onto the compressor housing; alternately tighten attachment screws (Fig. 4/ 3 ) to hand-tightness (tightening torque: 3.5 Nm).
6. Insert O-rings (Fig. 6/ 12 ) and flat seals ( 13 ) into the head connection receiver.
7. Reinstall the head connections: To do this, manually tighten the head connections’ attachment screws (Fig. 5/ 10 and 15 ).
8. Reinstall the head connection cover ( 8 ): To do this, manually tighten the head connection cover’s attachment screws ( 9 ).
9. Reinstall the head covers (Fig. 4/ 20 ): To do this, manually tighten the eight attachment screws ( 1 ).
10. Properly dispose of the old diaphragms, valve plates, and Orings.

disk spring

Page 38 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 38 · click to enlarge
Page 38

Servicing Diaphragm pump PJ25481-950.50.18

2. Remove from the intermediate plates (Fig. 8/ 6 ) the valve plates ( 16 ) and ( 17 ) and the O-rings ( 5 ) and ( 18 ).
3. Manually screw the ne diaphragms (Fig. 9/7) into the connecting rod’s threads and tighten to hand tightness.

Before you finally tighten the diaphragms, you are recom- mended to move the diaphragm to the upper dead center.

4. Insert the new valve plates (Fig. 8/ 16 ) and ( 17 ) and the new Orings ( 5 ) and ( 18 ) into the intermediate plates ( 6 ).

The upper and lower sides of the valve plates are identical.

When inserting the O-rings, make sure that they are the correct size and color (head 4: black O-rings).

Install intermediate plates and head cover

1. Place head plate (Fig. 8/ 4 ) onto the intermediate plates ( 6 ), observing the felt-tip pen marks (Fig. 6/ M ).
2. With your hands, carefully and lightly tighten the head plate’s head screw (Fig. 8/ 2 ) on all four heads (tightening torque: 60 Ncm).

Refer to for arrangement and alignment of disk springs and the screw’s washer. When inserting the O-rings, make sure that they are the correct size and color (head 4: black O-rings).

3. Place three O-rings (Fig. 7/ 19 ) into each of the head connection holes.
4. Press together heads 1 and 2 (Fig. 6/ I and II ) and heads 3 and 4 ( III and IIII ).
Fig. 10Aligning the
5. Place heads 1 and 2 and heads 3 and 4 onto the compressor housing; alternately tighten attachment screws (Fig. 4/ 3 ) to hand-tightness (tightening torque: 3.5 Nm).
6. Insert O-rings (Fig. 6/ 12 ) and flat seals ( 13 ) into the head connection receiver.
7. Reinstall the head connections: To do this, manually tighten the head connections’ attachment screws (Fig. 5/ 10 and 15 ).
8. Reinstall the head connection cover ( 8 ): To do this, manually tighten the head connection cover’s attachment screws ( 9 ).
9. Reinstall the head covers (Fig. 4/ 20 ): To do this, manually tighten the eight attachment screws ( 1 ).
10. Properly dispose of the old diaphragms, valve plates, and Orings.

disk spring

Page 39 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 39 · click to enlarge
Page 39

Diaphragm pump PJ25481-950.50.18 Servicing

1. Reconnect suction and pressure line on the pump.
2. Reconnect the pump to the mains.

If you have any questions about servicing, call your KNF technical adviser (contact data: see www.knf.com).

Final steps

Page 40 of the Memmert Pump Module (PM/PMP) user manual — DANGER
Page 40 · click to enlarge
Page 40

Troubleshooting Diaphragm pump PJ25481-950.50.18

9. Troubleshooting

Extreme danger from electrical shock!

Disconnect the pump power supply before work-

ing on the pump. Make sure the pump is de-energized and se-

DANGER

cure.

Check the pump (see Tab. 12 and Tab. 13).

Pump does not transfer Cause Fault remedy Pump not connected to the mains.

Connect pump to the mains.

No voltage in the mains. Check room fuse and switch on if necessary. The motor board’s overcur- rent protection circuit has activated.

Separate pump from the mains. Determine and remove the cause of the overcurrent (for ex-

ample: improper pressure, liquid in the pump heads).

Maximum temperature of motor board is exceeded.

The pump must be separated from the mains for several seconds before the electronics will permit restarting.

Maximum blocking time of the rotor is exceeded.

Connections or hoses are blocked.

Check hoses and connections. Remove blockage. External valve is closed or filter is clogged.

Check external valves and filters.

Condensate has collected in the pump head.

Detach the condensate source from the pump. Flush the pump (see Chapter 8.2.1). Diaphragm or valve plates are worn.

Replace diaphragm and valve plates (see Chapter 8.3).

Tab. 12

Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Fault remedy Condensate has collected in the pump head.

Detach the condensate source from the pump. Flush the pump (see Chapter 8.2.1). Presence of positive pressure on the pressure side with simul- taneous vacuum or positive pressure on the suction side.

Change the pressure conditions.

Cross-section of pneumatic hoses or connectors too narrow or restricted.

Disconnect the pump from system and determine output

values. Remove restriction (e.g. valve) if necessary. If applicable, use larger-diameter hoses or connectors. Leaks in connections, hoses or pump head.

Make sure the hoses and connections. Remove any parts or particles causing blockages. Pump head components are soiled.

Clean head components.

Page 41 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 41 · click to enlarge
Page 41

Diaphragm pump PJ25481-950.50.18 Troubleshooting

Pump head components are soiled.

Clean head components.

Diaphragm or valves plates are worn.

Replace diaphragm and valve plates (see Chapter 8.3).

Diaphragm and valve plates have been replaced.

Make sure that the shim rings have been replaced onto the

diaphragm screw thread. Check head connection and hose connections for leaks.

Tab. 13

Fault visualization on motor controller

The excess of the overcurrent limit, the excess of the maximum temperature of the motor board or the blocking of the rotor is shown as a fault. A red LED on the BLDC motor controller signals the cause of the fault.

Optional settings: If desired, the motor controller can be programmed so that the er- ror output voltage exhibits the same characteristics as the LED. With factory settings, only 1 or 0 are logically outputted as voltage at the fault output.

Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 41)
Fig. 30 · 6. Operating and installation information
Fig. 11LED blinking duration according to different faults

To delete the error condition the motor has to be disconnected from the mains.

Fault cannot be rectified

If you are unable to identify the cause of the problem, please send the pump to KNF customer services (contact data: see www.knf.com).

1. Flush the pump (see Chapter 8.2.1).
2. Clean the pump (see Chapter 8.2.2).
3. Send the pump, together with completed Health and Safety Clearance and Decontamination Form (Chapter 12), to KNF stating the nature of the transferred medium.
Page 42 of the Memmert Pump Module (PM/PMP) user manual — 10. Returns
Page 42 · click to enlarge
Page 42

Returns Diaphragm pump PJ25481-950.50.18

10. Returns

Pumps and systems used in laboratories and process-based industries are exposed to a wide variety of conditions. This means that the components contacting pumped media could become contaminated by toxic, radioactive, or otherwise hazardous sub- stances.

For this reason, customers who send any pumps or systems back to KNF must submit a Health and safety clearance and decontami- nation form in order to avoid a hazardous situation for KNF em- ployees. This Health and safety clearance and decontamination form provides the following information, among other things:

whether medium-contacting parts have been cleaned

whether the equipment has been decontaminated

media that have been pumped or used

To ensure worker safety, work may not be started on pumps or systems without a signed Health and safety clearance and decon- tamination form.

For optimal processing of a return, a copy of this declaration should be sent in advance via e-mail, regular mail, or fax to KNF Customer Service (contact data: see www.knf.com). In order to avoid endangering employees who open the shipment’s packag- ing, despite any residual hazards, the original version of the Health and safety clearance and decontamination form must accompany the delivery receipt on the outside of the packaging.

The template for Health and safety clearance and decontamination form is included with these Operating Instructions and may also be downloaded from the KNF website.

The customer must specify the device type(s) and serial number(s) in the Health and safety clearance and decontamination form in or- der to provide for the unambiguous assignment of the Declaration to the device that is sent to KNF.

In addition to the customer’s declaration of physiological safety, in- formation about operating conditions and der customer’s applica- tion are also of importance to ensure that the return shipment is handled appropriately. Therefore, the Health and safety clearance and decontamination form requests this information as well.

physiological safety

Page 43 of the Memmert Pump Module (PM/PMP) user manual — 11. Health and safety clearance and decontamination form
Page 43 · click to enlarge
Page 43

Diaphragm pump PJ25481-950.50.18 Health and safety clearance and decontamination form

11. Health and safety clearance and decontamination form

Memmert Pump Module (PM/PMP) — 11. Health and safety clearance and decontamination form diagram (page 43)
Fig. 31 · 11. Health and safety clearance and decontamination…
Page 44 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 44 · click to enlarge
Page 44
Page 44 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 45 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 45 · click to enlarge
Page 45
Page 45 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 46 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 46 · click to enlarge
Page 46
Page 46 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 47 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 47 · click to enlarge
Page 47
Page 47 of the Memmert Pump Module (PM/PMP) user manual — 6. Operating and installation information
Page 48 of the Memmert Pump Module (PM/PMP) user manual — Pump modul PM PMP
Page 48 · click to enlarge
Page 48
Memmert Pump Module (PM/PMP) — 6. Operating and installation information diagram (page 48)
Fig. 32 · 6. Operating and installation information

Pump modul PM PMP

D39489 I Date 12/2019 englisch

Memmert GmbH + Co. KG Postfach 1720 | D-91107 Schwabach Tel. +49 9122 925-0 | Fax +49 9122 14585 E-Mail: sales@memmert.com facebook.com/memmert.family

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Memmert Pump Module (PM/PMP)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Memmert Pump Module (PM/PMP)

Be the first to ask — other owners or our team will answer.

Original document

Memmert Pump Module (PM/PMP) manual PDF

48 pages·1.9 MB·Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…