HPB3619-6, HPB3619-12 & HPB4819-12 models
INSTALLATION GUIDE
US CA



2 PRODUCT INFORMATION
! WARNING!
The appliance is heavy. Please ensure adequate care is taken when installing the appliance to prevent personal injury.
Weight of the products are:

HPB3011-4 = 36lb (17kg) HPB3011-6 = 36lb (17kg) HPB3019-6 = 46lb (21kg) HPB3611-4 = 41lb (19kg) HPB3611-6 = 41lb (19kg) HPB3619-6 = 51lb (23kg) HPB3619-12 = 68lb (31kg) HPB4819-12 = 77lb (35kg)
INSERT RANGE HOOD
HPB3011-4, HPB3011-6, HPB3019-6, HPB3611-4, HPB3611-6,
HPB3619-6, HPB3619-12 & HPB4819-12 models
HPB3619-6, HPB3619-12, HPB4819-12,
HOTTE ENCASTRÉE
INSTALLATION GUIDE
Modèles HPB3011-4, HPB3011-6, HPB3019-6, HPB3611-4, HPB3611-6,
US CA
USER GUIDE
GUIDE D’UTILISATION
US CA
User guide and Installation guide
Always disconnect the appliance from the mains power supply before carrying out any maintenance or repairs.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Failure to do so can result in death, electric shock, fire or injury to persons.
Remote control (selected models) Duct adaptor including 5/16” (8mm) T20 drive screws (4) (selected models)
Adaptor ring including 5/16” (8mm) T20 drive screws (4)
Other required materials and tools:
! WARNING: Chemical Burn Hazard. Keep batteries away from children. This product contains a lithium button/coin cell battery. If a new or used lithium button/ coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. Even used cell batteries may cause injury so ensure they are kept away from children and disposed of properly.
Remote control kit – Remote control (1), Wireless receiver (1)

HPB3011-4, HPB3011-6, HPB3019-6, HPB3611-6, HPB3619-6, HPB3619-12 and HPB4819-12 models


M
G
H


Refer to page 4 for details on ‘Cabinet mounting installation’

D
1 1/2” (38mm)

For the larger models we recommend reinforcing your cabinetry. Please ensure that any reinforcing does not prevent access for servicing.
For optional recessed installation refer to product dimensions for reference.

INSTALLATION DIMENSIONS inches (mm)
A Top of cooking surface to base of the range hood
Minimum 30” (762) Maximum recommended 42” (1067)
The installation height ranges from a minimum height of 30” (762mm) to a maximum recommended height of 42” (1067mm). Consult the cooktop Installation and User guide for details of the required installation height of the range hood.
Installation location — Ducting preparation
This range hood must be installed no lower than the minimum height indicated in the table above. Minimum installation height may be greater if required by the cooktop manufacturer. Installation at the minimum height will improve the efficiency of capturing cooking odors, grease and smoke. Installation at the maximum recommended height improves user ergonomics by offering increased head room.
The range hood is suspended under the cabinetry. The ducting can be configured for both vertical and horizontal discharge. The ducting can terminate either through the roof or wall, to vent through the wall a 90° elbow is needed.
All optional extras must be installed prior to the range hood being installed.
Remote control If an optional remote control was purchased for installation with the range hood the remote control receiver must be assembled into the range hood prior to installation. Installation must be undertaken by an approved service technician. Instructions for installation are provided with the receiver.
– Using the maximum speed setting to enable hot
Duct adaptor A 8” (203mm) or 10” (254mm) round duct adaptor is supplied to mount to the top of the range hood to provide a single outlet. This should be installed before the range hood is mounted.
air to be extracted quickly. – Installing the range hood at the maximum
recommended height. Consult the cooktop Installation and User guide for details on the installation height of the range hood.



WARNING!
– In ducted installations with internal blowers, use 8” (203mm) or 10” (254mm)
round ducting. – For inline blowers use 10” (254mm) round ducting.
Make-up air (not included) Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled. Local building codes may require the use of make-up air systems when using ducted ventilation systems greater than specified cubic feet per minute (CFM) of air movement. The specified CFM varies from locale to locale. It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
Vent through roof Vent through exterior wall
Compatible blowers with this range hood This range hood may only be used with:
To minimize noise in the kitchen, these blowers are mounted along the duct line anywhere between the kitchen and the exterior wall.
Electrical requirements · Venting requirements

1 Ensure the cabinetry has the required cutout for insertion of the range hood. Refer to the ‘Cabinetry cutout dimensions’ section of this installation book. 2 If you are using a duct adaptor this must be installed to the range hood prior to the range hood being mounted. Please refer to ‘Duct adaptor assembly’ for details on how to install your duct adaptor. 3 Ensure the mounting brackets are set to the correct position for installation by checking the top of the foot lines up with the notches (refer to C). Note: Adjusting the mounting bracket up or down from this position prior to installation could cause the range hood to be difficult to install and/or damage the cabinetry. 4 Lift the range hood into the opening until the spring loaded mounting brackets click into place and support the weight of the range hood (refer D). For larger size range hoods this will require two people. Note: Depending on the cabinetry base panel thickness the range hood will be protruding below the cabinetry until tightened. 5 Secure the range hood into the cabinetry by tightening each of the mounting brackets in a counterclockwise direction (refer to E). Tighten each bracket in succession around the range hood to close the gap incrementally for each bracket. 6 Remove the junction box cover by removing the two screws (refer to F). 7 Remove the electrical knockout and install a cULus listed 1/2” (12.7mm) wiring conduit and strain relief in the junction box. 8 Run three wires through the conduit from the power supply to the junction box. 9 Connect the power supply wires to the range hood wires using suitable cULus listed wire nuts:
Before you start installation
– black to black – white to white – green/yellow to green/yellow !0 Close the junction box cover and secure with screws.
!1 Complete the installation








© Fisher & Paykel Appliances 2019. All rights reserved.
The product specifications in this document apply to the specific
products and models described at the date of issue. Under our policy
of continuous product improvement, these specifications may change
at any time. You should therefore check with your Dealer to ensure this
booklet correctly describes the product currently available.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.