Page 2 of the Bowens Studio Flash (125) user manual — Dear Customer!
Page 2 · click to enlarge
Page 2

Dear Customer!

We are grateful for your choice. We are sure that this product will meet all your needs, and the quality will correspond to the best world standards.

ATTENTION! Before using the equipment, read the rules of safety technology. Their strict observance will ensure the correct operation of devices and your personal safety during operation.

ATTENTION! Be careful! The equipment has dangerous voltages up to 16 kV.

Lighting devices are designed to work in normal conditions without increased electrical hazard. Conditions that create increased electrohazard are: - high humidity and dustiness of air; - conductive floors; - ambient temperature above +400C; - aggressive environment. In order to avoid accidents, it is prohibited: - include the device in the network with a removed casing, touch mounting wires, individual parts and nodes located in the power unit; - replace fuses when the plug of the grid cable is included into the electrical outlet, use safety locks whose types and denominations are different from those given in this Guideline; - use illuminators when the isolation of the power supply cable is broken; - clean the surface of devices with aerosols, solvants and other liquids.

Inside the housing of lighting there are no components and parts, repair which could be carried out by the user himself. For repairs, contact the specialists of the manufacturer or its authorized regional offices.

Storage and operation of equipment should be carried out indoors without exposure to aggressive media (acid vapors and alkalis, corrosive gases and other harmful impurities) at ambient temperature from + 100C to + 350C and relative humidity up to 80%. Transportation of equipment should be carried out in protective packaging without impact and deformation loads. After the equipment is forced to be found at a temperature below + 50 C, it should be kept in a warm room before being included into the power grid for 2 hours.

Page 3 of the Bowens Studio Flash (125) user manual — COMPLETENESS OF DELIVERY
Page 3 · click to enlarge
Page 3

COMPLETENESS OF DELIVERY

  • Esprit Gemini 500 monoblock with pulse lamp
  • Operational manual
Bowens Studio Flash (125) — COMPLETENESS OF DELIVERY diagram (page 3)
Fig. 2
1. Handle 2. Turning on/off light synchronization 3. Turning on/off the sound signals 4. Switch modes of pilot light 5. Synchrojack 6. Power switch network/battery 7. Connector for the network cable 8. Safety locks 9. The connector for autonomous power supply 10. Photosynchronizer 11. The fixing of accessories 12. Flash power regulator 13. Readiness indicator 14. Test button 15. The power regulator of the pilot light Fig. 1st
Page 4 of the Bowens Studio Flash (125) user manual — FEEDING
Page 4 · click to enlarge
Page 4
  • Before you start installing or replacing a pilot lamp, always turn off the device and disconnect it from the network. Wait a few minutes until the lamp and pulse tube cools Include the bulb in a standard cartridge at the center of the reflector. If the new lamp does not work, check the fuse as it may have burned out when the previous bulb failed. Note: In Esprit Gemini monoblocks, it is recommended to use Photoflood or Halostar lamps with a power of no more than 275 watts. The manufacturer and seller shall not be liable in the event of a lamp with power exceeding 275 watts. The device operates from an alternating current network with a voltage of 195-260 V and a frequency of 50 Hz or from the autonomous Travel-Pak power supply unit. For operation from the mains, a power switch (see para. rice. 1.6) shall be in the upper position to operate from the battery at the bottom. The average position of the switch is to turn off the device. Never connect the device to a 220V network and an autonomous Travel-Pak power supply at the same time. Flash power has smooth control from maximum to 1/32. At maximum power, using a reflector 50o Keylite and film 100 ISO leading number 82. Turning the handle (Figure 1). 2.12) by one division is equivalent to a change in power of one third of the stage. The flash is included in one of the three following ways:
  • "TEST" button (Figure 1). 2.14)
  • External synchronization through the synchronest (Figure 1). 1.5) A standard 1⁄4-inch sync nest located on the back of the instrument may be used for direct connection to the camera. Remote start-up devices, such as Omni-cells can
Page 5 of the Bowens Studio Flash (125) user manual — REFLECTORS AND OTHER ACCESSORIES
Page 5 · click to enlarge
Page 5

be connected to the synchronous nest directly or through an extension wire. • Light synchronization Built-in photocell (Figure 2). 2.10) allows synchronization of the flash of a monoblock with another device or small camera flash. The photocell is located at the top of the device under a red semi-transparent protective panel. PILOT-LIGHT When a switch controlling the pilot lamp (Figure 2). 1.4) is in the upper position, pilot lamp unplugged. When the switch is in a lower position, the pilot lamp goes out after the flash has been triggered and lights up again once the device recharged, allowing the photographer behind the camera to determine if the flash was working. With the middle position of the switch, the pilot lamp burns constantly. The brightness of the pilot lamp shall be controlled by a handle (figure 2). 2.15). SAFETY-GUARD The flash circuits and the pilot lamp are protected by a 5-ampere (F) 20-mm fuse inserted into the socket on the rear panel (Figure 1). 1.8). Never use a safety lock of another type. Since the fuse can burn out when a pilot lamp fails, always check the safety lock before replacing it. The device comes complete with a spare fuse. Always turn off the device before replacing a pilot lamp or fuse. SOUND-INDICATION The audible readiness indication shall be switched on (Figure 2). 1.3.), located on the back of the instrumentation. REFLECTORS AND OTHER ACCESSORIES Place a reflector/accessoir on the front of the monoblock. Combine three landing stops with holes on the locking ring, press and turn clockwise to point. Make sure the lock is in a locked state. To remove the reflector, press on the lock in the direction of the back panel and turn the reflectors counterclockwise.

Page 6 of the Bowens Studio Flash (125) user manual — WORK-WORK
Page 6 · click to enlarge
Page 6

To work with an umbrella, you first need to install a wide-angle reflector. Then insert the umbrella into the hole of the fastening bracket of a wide-angle reflector and fix it with a clamp screw. When installing and removing reflectors and other accessories, pay special attention to not damage the mount of the pulse lamp. Always turn off and disconnect the monoblock from the network before replacing a pulse lamp. Impulse lamp replacement Attention: high voltage. Never touch a pulse lamp less than 30 minutes after disconnecting from the mains. Make sure the appliance is off and disconnected from the network, and wait at least 30 minutes. Remove the protective cap and unwind the trigger wire. Carefully remove the pulse lamp from the device. To install a new lamp, take it as shown in Fig.2, holding both contacts, and gently set to place, after which wind the trigger wire. Always use one of two types of pulse lamps: BW-2032 (UV coated) or BW2030 (uncoated).

Bowens Studio Flash (125) — WORK-WORK diagram (page 6)
Fig. 3

Rice. 2. MANNER OF WORK Turn the instrument on and set the switches of sound, light synchronization and pilot light in the desired position. Set the required flash power level and brightness of a pilot lamp. After charging the device to the required level, a green readiness indicator will light up (Figure 2). 2.13). Insert the synchronous cable and connect to the camera, or use a built-in photocell for syncing.

Page 7 of the Bowens Studio Flash (125) user manual — GUARANTEE
Page 7 · click to enlarge
Page 7

Or connect the IR receiver or Omnicell. After reducing the flash power, use the "TEST" button (Figure 1). 1.4) to discharge excess energy. INSTALLATION Choose a tripod or suspension system of the appropriate size and strength to ensure stable operation. The L-bracket device allows the instrument to be installed in two different ways (Figure 2). 3). Method B can be used when you want to direct the light stream down. Make sure the screw clamp is tightly twisted.

Bowens Studio Flash (125) — INSTALLATION diagram (page 7)
Fig. 4

Rice. 3

MAINTENANCE

Warranty and post-warranty maintenance is carried out by the specialists of the manufacturer or its authorized regional representatives. When warranty service of devices, presentation of a guarantee card with a mark on sale is mandatory. Do not attempt to repair your equipment yourself.

GUARANTEE

The manufacturer guarantees the proper operation of devices within one year from the date of shipment to the consumer, subject to strict compliance by the buyer with the operating rules set out in this Guide.

Page 8 of the Bowens Studio Flash (125) user manual — TECHNICAL CHARACTERISTICS
Page 8 · click to enlarge
Page 8

TECHNICAL CHARACTERISTICS

Bowens Studio Flash (125) — TECHNICAL CHARACTERISTICS diagram (page 8)
Fig. 5
ModelEsprit Gemini 250Esprit Gemini 500Esprit Gemini 750+ Model codeBW-3600BW-3610BW-3630 Power250 J500 J750 J Lead number (M/ISO 100)6082 104 Recharging to full capacity0,85 с1,0 с 1,41 с Pulse duration T = 0.51/1100 с1/700 с1/2380 с Depth of adjustmentfull-onfull-onfull-on Recommended pilot lamp275W Photoflood or 250W Halostar275W Photoflood or 250W Halostar275W Photoflood 250W Halostar Adjustment of the pilot lampmax to 1/32max to 1/32max to 1/32 Stress stabilizationup to ±1%up to ±1%up to ±1% Readiness light indicationAt 100% charging.At 100% charging.At 100%. charging SizeN: 145 mm V: 130 mm D: 365 mmN: 145 mm V: 130 mm D: 365 mmN: 145 mm B: 130 mm D: 365 mm Weight.2.9 kg3.4 kg4.0 kg All Esprit Gemini monoblocks have the following characteristics:- User-replaceable pulse lamp (UV) or transparent. - Pulse lamp with UV coating gives color temperature 5600K (±300K). - Fixing accessories with the help of "S"-bayonet Bowens. - Consumption voltage 195-260V, 50/60Hz. - 5B synchronocontact voltage.

Bowens International Limited constantly improves its products and reserves the right to change their specifications without notice.

Ask about the Bowens Studio Flash (125)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bowens Studio Flash (125)

Be the first to ask — other owners or our team will answer.

Original document

Bowens Studio Flash (125) manual PDF

8 pages·530 KB·Camera Accessories·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…