EN
Bowens logo
Official user manual

Bowens BWL-0410

10 pages·655 KB·Camcorder·PDF·ENDEFRITNLJA
Bowens BWL-0410
Table of Contents 46 sections OPERATING INSTRUCTIONS · Side Control Panel · Rear Control Panel · Control Panel Guide · … ShowHide
Page 1 of the Bowens BWL-0410 user manual — OPERATING INSTRUCTIONS
Page 1 · click to enlarge
Page 1

ʻBowensʼ ® and ʻthe power behind the pictureʼ ® are registered trademarks of Bowens International Ltd.

Tel+44 (0)1255 422807 Fax: +44 (0)1255 436342

355 Old Road Clacton On Sea Essex CO15 3RH

ESPRIT GEMINI DIGITAL USER GUIDE BWL-0410 (10/06) BOWENS INTERNATIONAL LIMITED

Bowens BWL-0410 — OPERATING INSTRUCTIONS diagram (page 1)
Fig. 1

OPERATING INSTRUCTIONS

Page 2 of the Bowens BWL-0410 user manual — OPERATING INSTRUCTIONS
Page 2 · click to enlarge
Page 2
Page 2 of the Bowens BWL-0410 user manual — OPERATING INSTRUCTIONS
Page 3 of the Bowens BWL-0410 user manual — Mounting
Page 3 · click to enlarge
Page 3

Side Control Panel

Rear Control Panel

Control Panel Guide

Bowens BWL-0410 — Control Panel Guide diagram (page 3)
Fig. 2 · Control Panel Guide

Rotary Dial Menu Button Flash Test / Done Button LED Display

Bowens BWL-0410 — Control Panel Guide diagram (page 3)
Fig. 3 · Control Panel Guide

Fuse (and spare fuse)

Mains / Battery Power Select

Mount the Esprit Gemini Digital unit on selected support system. The mounting bush on the 'L' bracket allows for two possible ways of mounting to the stand / support. Method B may be found useful if the light is required to point down.

When connecting a power supply ensure the power is OFF. Connect the unit using the appropriate cabling. If using a battery source, ensure the connector locks are fully tightened. Switch the power source on, then switch on the unit. The unit will charge and indicate it is ready for use. Press the TEST button to check the unit fires.

For mains operation, the mains switch (page 4) should be in the upper position (I). For battery operation the switch should be in the lower position (II). The centre position is OFF (O). NOTE: When operated from a battery source, the modelling lamp functions are not available.

The Esprit Gemini Digital unit may be operated either on a mains supply or with a Bowens battery source such as the Bowens Travel-Pak, Turbo-Pak or the Explorer 1500.

Bowens BWL-0410 — Control Panel Guide diagram (page 3)
Fig. 4 · Control Panel Guide

NEVER CONNECT THE ESPRIT GEMINI DIGITAL TO BOTH A MAINS SUPPLY AND A BATTERY SUPPLY AT THE SAME TIME. THIS APPLIANCE MUST BE EARTHED WHEN USED WITH MAINS. DISCONNECT THE MAINS LEAD WHEN CHANGING MODELLING LAMPS & FLASH TUBES.

B A

!!! WARNING HIGH VOLTAGE !!!

Connecting & Using the Esprit Gemini Digital

Bowens BWL-0410 — B A diagram (page 3)
Fig. 5

Mounting

Show 5 more labels / short text on this page
Latch Release · Battery Power Inlet · Carry Handle · Sync Socket · Mains Inlet
Page 4 of the Bowens BWL-0410 user manual — Flash Power Control
Page 4 · click to enlarge
Page 4

Photocell: The Esprit Gemini has a built in switchable photocell enabling the unit to be triggered by the flash from any other flash unit or a small camera mounted flash gun. The photocell is mounted behind the red transparent cover on the top of the unit. The Photocell has various trigger modes, see page 12 for full details.

There are several ways to trigger the Esprit Gemini Digital

The modelling and flash circuitry is protected by a single 20mm fuse mounted on the rear panel. Never replace the fuse with one of a different rating. As the fuse may blow when the modelling lamp fails always check the fuse when replacing the bulb. A spare fuse is supplied and located in the fuse holder at the back of the unit. Always switch OFF and disconnect the Esprit Gemini unit from the power supply before changing the bulb or fuse.

If an umbrella is to be used a 'Wide Angle Reflector' should be fitted and the umbrella fitted through the mounting hole in the mounting bracket and locked in position with the knurled screw.

To remove reflector, pull back Latch Release Key (page 4), turn the reflector fully anti-clockwise and withdraw.

A wide range of reflectors are available for the Esprit range. To fit, slide the neck of the reflector over the front of the unit. Align the three pegs on the reflector with the three slots in the retaining ring. Press down and turn clockwise to lock.

Switch off and disconnect from the supply. Screw modelling lamp into ES lampholder in the centre of the reflector. Allow lamp to cool before removing.

Synchronisation

Fuse

Fitting / Removing Reflectors

Fitting the Modelling Lamp

The ʻFlash Powerʼ, ʻModelling Lampʼ and ʻOther Optionʼ settings are all available by using the ʻrotary controlʼ on the side of the unit in combination with the ʻMENUʼ and the ʻDONEʼ button; all of the options and settings can be seen via the 7-segment LED display above the buttons. All of the various options and settings are stored to the unitʼs memory.

GEMINI Digital User Controls

The modelling lamp control options are available within the ʻnormal functionsʼ through the digital display on the side of the unit. The modelling lamp options that are available are either OFF, USER (in USER mode the modelling lamp output can be set from F5.0 to F10.0), PROPORTIONAL (modelling lamp automatically adjusts itself to be in proportion to the flash power output), or FULL (the modelling lamp is set to maximum power output).

The Flash Power display can also be ʻinvertedʼ so it is displayed upside down. This is a useful feature when using the unit from a ceiling mounted rail system when the unit will be upside down. This feature is available through the Advanced Functions menu. Note: If the unit is subjected to rapid operation over extended periods, it may automatically go into an overheat condition. In this condition the charging and modelling functions are disabled in order to allow the unit to cool. The unit will automatically resume operation once cooled sufficiently.

The flash power output is variable over five f-stops from full to 1/32 power, in 1/10 stop increments. The maximum power available depends upon the model (See specification table). The Flash Power output value which is shown on the side of the unit can be set to be displayed in either f-stops or Joules (Ws). The Flash Power display setting can be changed via the ʻAdvanced Functionsʼ in the menu system.

Open Flash: For testing or multiple flash applications the Open Flash Push button can be used.

Sync Socket: The standard quarter inch jack type socket on the rear panel of the unit may be used for direct connection to a camera set to 'x' synchronisation. Two Esprit units may be connected together using a 'y' connector. An Infra Red Receiver, Omnicell or Pulsar Radio Trigger systems may also be plugged into this socket. The socket operates at +5V and is safe for use on digital cameras.

Modelling Lamp Control

Synchronisation cont.

Flash Power Control

Functions Overview

Page 5 of the Bowens BWL-0410 user manual — Normal Functions
Page 5 · click to enlarge
Page 5

Example Illustration: How to change the Modelling Lamp to off.

At any menu level turning the rotary control will either select another function/option or change the setting of the chosen function. Each press of the ʻDONEʼ button takes you up one level until you exit the user setup mode, at which point ʻEndʼ is displayed. Any altered user setting will be saved to the units memory. See below illustration for example of how to change the Modelling Lamp settings to off.

To change any of the unitʼs settings first press the ʻMENUʼ button on the side of the unit; ʻSETʼ will be displayed briefly showing that the unit is entering the user setup options followed by ʻLPʼ (for ʻLamp settingsʼ) as the first item. Each press of the ʻMENUʼ button takes you down one level of the menu structure until you cannot go any further; at this point the sounder (if switched on) will provide a warning beep.

The unit can be triggered via the ʻsync socketʼ connected to the relevant system or via the ʻPhotocellʼ as required. Other displays may occur during operation to provide warnings of problems or to indicate the unit status.

FunctionDisplayDescription *LampLPOff (OFF) - Lamp remains ʻoffʼ during operation. USER (USR) - In ʻuserʼ mode the modelling lamp can be adjusted from f5.0 to f10.0 Proportional (PRO) - In ʻproportionalʼ mode the modelling lamp will automatically adjust itself to the same output level as the flash. Full (FUL) - When the modelling lamp is set to ʻfullʼ the power output will remain at the maximum level. *Lamp Ready IndicationINDOff (OFF) - No lamp ready indication. Intermittent (INT) - If modelling lamp is on it goes off after the unit has fired and comes back on at the set level once the unit has recharged. Pulse (PUL) - Modelling lamp pulses when the unit has recharged after firing. Ready SounderSNDOff (OFF) - The Ready Sounder beep remains off and does not indicate when the unit has charged. Intermittent (INT) - The unit emits a short beep when it has fully recharged to indicate that it is ready to fire again. Continuous (CON) - The unit emits a continuous beep while it is recharging and stops once fully recharged. PhotocellPHOOff (OFF) - Photocell remains ʻoffʼ. 1st (1st) - Photocell is set to trigger unit on the first flash detected. 2nd (2nd) - Photocell is set to trigger on the second flash detected. 3rd (3rd) - Photocell is set to trigger on the third flash detected. 4th (4th) - Photocell is set to trigger on the fourth flash detected.

Step Three. Once the desired setting is shown press the MENU button again to enter the available functions for that particular setting.

Step Two. Next, turn the rotary dial to scroll through the normal functions.

Step One. During normal operation press the MENU button to enter the normal functions menu.

Step Six. Next press the TEST/DONE button to confirm your selection and go up one menu level. Repeat as necessary with other functions. Finally press TEST/DONE until END is displayed.

Step Five. Scroll through the available options until the desired setting is shown.

Step Four. Next turn the rotary dial again to find the desired option of the setting you wish to change.

www.bowens.co.uk 9 * Only available when operating from mains power.

Ready Sounder SND Off (OFF) - The Ready Sounder beep remains off and does not indicate when the unit has charged.

*Lamp Ready Indication IND Off (OFF) - No lamp ready indication.

Photocell PHO Off (OFF) - Photocell remains ʻoffʼ.

4th (4th) - Photocell is set to trigger on the fourth flash detected.

3rd (3rd) - Photocell is set to trigger on the third flash detected.

2nd (2nd) - Photocell is set to trigger on the second flash detected.

1st (1st) - Photocell is set to trigger unit on the first flash detected.

Continuous (CON) - The unit emits a continuous beep while it is recharging and stops once fully recharged.

Intermittent (INT) - The unit emits a short beep when it has fully recharged to indicate that it is ready to fire again.

Pulse (PUL) - Modelling lamp pulses when the unit has recharged after firing.

Intermittent (INT) - If modelling lamp is on it goes off after the unit has fired and comes back on at the set level once the unit has recharged.

Full (FUL) - When the modelling lamp is set to ʻfullʼ the power output will remain at the maximum level.

Proportional (PRO) - In ʻproportionalʼ mode the modelling lamp will automatically adjust itself to the same output level as the flash.

USER (USR) - In ʻuserʼ mode the modelling lamp can be adjusted from f5.0 to f10.0

Normal Functions

Page 6 of the Bowens BWL-0410 user manual — Functions Menu System
Page 6 · click to enlarge
Page 6

Advanced Functions

Audio (Key Clicks & Warnings)

Function Display Description

FunctionDisplayDescription Audio (Key Clicks & Warnings)AUDOff (OFF) - All audible beeps/clicks are turned off during normal operation i.e. while scrolling through the functions menu. On (ON) - All audible beeps/clicks are enabled while unit is powered on. Power DisplayUNTf-stops (F-S) - Power output is displayed in f-stops. Joules (JOU) - Power output is displayed in Joules (Ws). Display InvertINVOff (OFF) - LED display invert option remains ʻoffʼ during operation. On (ON) - LED display is inverted and is shown upside down. Flash DumpFldOff (OFF) - Unit will not automatically dump any excess power. On (ON) - The unit will automatically dump any excess power stored in the capacitors after the user has turned down the power.

AUD Off (OFF) - All audible beeps/clicks are turned off during normal operation i.e. while scrolling through the functions menu.

On (ON) - All audible beeps/clicks are enabled while unit is powered on.

* Only available when operating from mains power.

Bowens BWL-0410 — Function Display Description diagram (page 6)
Fig. 6 · Function Display Description

PHO OFF, 1st, 2nd, 3rd, 4th

SND OFF, INT, CON

*IND OFF, INT, PUL

*LP OFF, USR, PRO, FUL

FLD OFF, ON

UNT F-S, JOU

AUD OFF, ON

INV OFF, ON

set from F-5 to F-10

set time window from 10 to 990ms

Functions Menu System

Menu Top Level

Page 7 of the Bowens BWL-0410 user manual — Audible Ready Beep
Page 7 · click to enlarge
Page 7

Now press the shutter release fully with the camera facing the unit. The number of pre-flashes detected will be shown on the display. N.B. if more than 4 flashes are detected within the time window then the photocell will be turned off. Press the ʻMENUʼ button and the flash detection timeout period will now be shown (2,3 and 4 only). Rotate the dial to obtain the required value - typically the default of 300mS should be adequate for most cases.

While carrying out the following procedure ensure that no other flash is likely to be used in the vicinity until the settings have been saved. To allow the flash unit to learn the camera characteristics first set up the camera in the required mode (i.e. flash, pre-flash, red-eye reduction etc). Now press ʻMENUʼ on the flash head and rotate the dial to select the ʻPhoʼ function and press ʻMENUʼ again, the current ʻPhoʼ option will now be shown; set the unit to 1st flash.

Where two or more flashes are to be detected a ʻtime windowʼ is started on detection of the first flash in the sequence. If the required number of flashes are detected within the ʻtime windowʼ then the unit is triggered on the last flash and the system is reset to wait for the next flash. If fewer than the required flashes are detected then the system is reset at the end of the time window. The ʻtime windowʼ can be set by the user from 10mS to 990mS for 2, 3 or 4 flashes. For obvious reasons there is no actual time window for a single flash since the unit triggers as soon as the flash is detected. As well as being able to select the number of flashes manually, the unit can also ʻlearnʼ the number of required pre-exposure flashes produced by any camera. This is done by setting the number of flashes to 1st. This provides the maximum detection window of 990mS when in ʻlearnʼ mode.

The Photocell on the Gemini Digital has an option to enable camera pre-exposure flashes to be ignored. These are used for exposure measurement and/or red eye reduction. This allows the flash unit to be synchronised to the camera shutter on the 1st, 2nd, 3rd or 4th flash selected by the user. (this option is for those who wish to trigger theIr flash heads without a radio or IR triggering system or without a sync cable). 1st is the normal ʻinstantʼ trigger where only one flash is used coincident with the shutter.

The Photocell is a light sensitive trigger which allows the photographer a way of triggering their stand alone flash heads that are not syncʼd by a cable. The photocell (when on) triggers the unit when another flash or light source is detected (i.e. when another flash head is fired and the photocell detects this it will fire the unit in synchronisation with the original light source).

Pulse (PUL) - Lamp pulses once fully recharged after firing. The pulse ready indicator option is available whether the ʻLampʼ settings are on or off.

Modelling Lamp Ready Indicator

DisplayDescription X-X or XX-Power display in either digital f-stops or Joules (Ws), in Lamp User setup mode this shows the equivalent power setting of the modelling lamp but always in digital f-stops. If this display is steady then this indicates the unit is READY and can be flashed. If this display is flashing quickly then this indicates that the unit is charging to the required setting. If this display is flashing slowly then this indicates the flash power needs to be dumped.(this can be done automatically by setting ʻFldʼ to ʻonʼ or manually by pressing the ʻTESTʼ button). ʻChrʼDisplayed after a successful flash whilst charging. ʻHotʼUnit is in overheat and will automatically reset when cooled. ʻEr1ʼFailure to charge correctly at ʻswitch-onʼ. Long sounder if on. This could be due to low mains input or leaky capacitors. After retrying and rechecking a number of times the unit will automatically lock out with the display showing ʻEr1ʼ but with the sounder silenced. ʻEr2ʼFailure to charge correctly after a flash (sound if on). The most likely cause here is that the tube glowed on. After retrying for a number of times and each time applying a longer glow stop period the unit will automatically lock out with the display showing ʻEr2ʼ but with the sounder silenced. ʻEr3ʼFailure of the tube to fire (sound if on).

The following normal displays and error codes are displayed together with a sound if appropriate and if ʻSoundʼ & ʻAudioʼ are switched ʻonʼ.

There is an Audible Ready Beep signal which is available to provide either a short beep to indicate when the unit is charged and ready to fire at the desired power output or sound continuously when charging. The Audible Ready Beep options are available through the Normal Functions on the unit.

Display Description

ʻEr3ʼ Failure of the tube to fire (sound if on).

ʻEr2ʼ Failure to charge correctly after a flash (sound if on). The most likely cause here is that the tube glowed on. After retrying for a number of times and each time applying a longer glow stop period the unit will automatically lock out with the display showing ʻEr2ʼ but with the sounder silenced.

ʻEr1ʼ Failure to charge correctly at ʻswitch-onʼ. Long sounder if on. This could be due to low mains input or leaky capacitors. After retrying and rechecking a number of times the unit will automatically lock out with the display showing ʻEr1ʼ but with the sounder silenced.

ʻHotʼ Unit is in overheat and will automatically reset when cooled.

ʻChrʼ Displayed after a successful flash whilst charging.

Power display in either digital f-stops or Joules (Ws), in Lamp User setup mode this shows the equivalent power setting of the modelling lamp but always in digital f-stops. If this display is steady then this indicates the unit is READY and can be flashed. If this display is flashing quickly then this indicates that the unit is charging to the required setting. If this display is flashing slowly then this indicates the flash power needs to be dumped.(this can be done automatically by setting ʻFldʼ to ʻonʼ or manually by pressing the ʻTESTʼ button).

Information & Error Codes .

Audible Ready Beep

or

Page 8 of the Bowens BWL-0410 user manual — Battery Power
Page 8 · click to enlarge
Page 8
Bowens BWL-0410 — Battery Power diagram (page 8)
Fig. 7 · Battery Power

The Esprit Gemini Digital is great studio monolight, but what about if you need to work out on location?

The ʻkey clickʼ & ʻwarning sounderʼ can be turned ʻonʼ or ʻoffʼ independently of the ʻreadyʼ sounder. This option is available within the Advanced Functions.

The modelling lamp has a micro controlled soft ʻonʼ and ʻoffʼ to prolong the life of the bulb.

Battery Power

Flashtube Replacement

Additional Information

BW2032 UV coated BW2030 Clear

Spare/Replacement Flashtubes.

To replace the assembly, hold the flashtube as shown and taking care to support both legs gently but firmly push the flashtube into position. Next wind the trigger wire around the flashtube support. Always replace with the correct flashtube assembly.

Gently pull the flashtube assembly out of the unit.

Remove the protective cap and unwind the twisted wire from the flashtube support.

Ensure that the unit is switched off and disconnect from the mains supply and then wait thirty minutes before touching/removing the flashtube.

Travel-Pak BW7631 Travel-Pak+ BW7638

Included in Bowens range of battery packs are the Travel-Pak and the larger Travel-Pak+. With a fast / slow charge option to prolong the life of the battery as well as a stylish carry bag offering protection from the elements and up to 3 inches of water; no location photographer should be without these handy packs.

Thanks to Bowens handy battery packs, your Bowens Esprit Gemini Digital units can leave the studio to go on location anytime, anywhere.

Bowens BWL-0410 — Battery Power diagram (page 8)
Fig. 8 · Battery Power

Pulsar BW5150 Pulsar (Twin Pack) BW5160

Because of its low-voltage operation, it is perfect for digital cameras. Each unit can be used as either a transmitter or receiver and operates using only two AAA batteries.

Because the Pulsar is a radio transmitter rather than IR, it allows for triggering around corners or through walls and is not affected by high ambient light situations. Choose from four individual channels and six studio setting per channel, each providing a unique ID for different flash devices or combine them to trigger all equipment within a given setup or studio.

This multifunctional device can be used to trigger flash units, film and digital cameras and light meters up to 100m away.

With the Esprit Gemini Digital monolights you are free from mains power. With the Pulsar Radio Trigger system you can be free from sync cables too.

Travel-Pak Boost Battery BW7635 Spare Explorer Battery BW7642 Travel-Pak/Explorer to Gemini Spare Cable BW7632 Bowens Universal 2Amp SLA Charger BW1227 Car Charger BW1245

Also Available for the Bowens battery range:

Explorer Battery Generator BW7640

Total freedom and flexibility, whenever and wherever quality light is required.

In addition, two Bowens Gemini sockets allow the photographer anything up to four light sources and a massive 3000Ws from this feature rich pack.

increment and accuracy.

The Bowens Explorer 1500 represents the state-of-the-art in portable battery generator technology. Weighing just under 12kg, this petite power- pack boasts an enviable power-to-size ratio and recycling capacity while providing photographers with the flexibility of two independent digitally controlled channels for use with Bowens Quad heads, both with 1/10 stop

Pulsar Radio Trigger

Bowens BWL-0410 — Pulsar Radio Trigger diagram (page 8)
Fig. 9 · Pulsar Radio Trigger
Bowens BWL-0410 — Pulsar Radio Trigger diagram (page 8)
Fig. 10 · Pulsar Radio Trigger

Battery Power

Page 9 of the Bowens BWL-0410 user manual — Accessories
Page 9 · click to enlarge
Page 9

High-Performance Reflector

Grid Diffuser

75° Softlite Reflector

BW5155

With The Pulsar clip-on platform is a handy way of attaching your radio trigger units to almost anything around your studio or even whilst out on location. Simply attach your loose Pulsar unit to the platform and clip onto whatever you need to. A great way of saving valuable time and effort in the studio.

Bowens BWL-0410 — High-Performance Reflector diagram (page 9)
Fig. 11 · High-Performance Reflector
Bowens BWL-0410 — High-Performance Reflector diagram (page 9)
Fig. 12 · High-Performance Reflector
Bowens BWL-0410 — High-Performance Reflector diagram (page 9)
Fig. 13 · High-Performance Reflector

Accessories

Pulsar Clip-On Platform

Bowens BWL-0410 — Accessories diagram (page 9)
Fig. 14 · Accessories
Bowens BWL-0410 — Accessories diagram (page 9)
Fig. 15 · Accessories
Bowens BWL-0410 — Accessories diagram (page 9)
Fig. 16 · Accessories

This 15” matt-finished reflector is supplied with a double diffuser cap that covers the flash tube and modelling lamp for added softness. The softest of Bowensʼ direct reflectors, it is perfect for portraiture, beauty and small product photography. The diffuser cap can be removed, making it an excellent large-diameter direct reflector. BW1899

This is an accessory to the 75° Softlite reflector that creates a unique lighting effect by including a Perspex outer diffuser with a honeycomb and grid in the centre. The Grid Diffuser gives a pool of direct light in the centre of the image, surrounded by soft- diffused light. The ratio between the centre and edge is 3:1 - ideal for portrait applications. BW1866

This 32cm reflector achieves the maximum amount of light output possible for lighting large groups and bouncing light off of high ceilings. The efficient parabolic design delivers a narrow, bright beam of light with intense shadows and high contrast. A must where sheer power is required. BW1878

Bowens BWL-0410 — Accessories diagram (page 9)
Fig. 17 · Accessories

40° Sunlite Reflector

A set of colour gels including seven popular colours, a neutral-density filter and two diffusers for heightened lighting creativity is also available for the Backlite reflector. BW2552

Backlite Reflector

65° Maxilite Reflector

Bowens BWL-0410 — Backlite Reflector diagram (page 9)
Fig. 18 · Backlite Reflector
Bowens BWL-0410 — Backlite Reflector diagram (page 9)
Fig. 19 · Backlite Reflector

DID YOU KNOW? that Bowens have over 40 light shaping tools and accessories available for all their monolights that use the current ʻSʼ type accessory fitting. Included among the range of accessories are a wide variety of reflectors and softboxes. For more information visit the website on www.bowens.co.uk

Bowens BWL-0410 — Backlite Reflector diagram (page 9)
Fig. 20 · Backlite Reflector
Bowens BWL-0410 — Backlite Reflector diagram (page 9)
Fig. 21 · Backlite Reflector

This is a good general-purpose direct reflector with an even coverage and a high light output. Since it has a small 20cm (8”) diameter, the light it produces is moderately high in contrast. The stippled surface ensures a smooth and even light distribution. BW1887

A 43cm (17”) white-painted reflector designed to replicate sunlight for photographing items such as architectural models. The white painted interior of the Sunlite helps to ensure that an even light is delivered. BW1868

With its 20 x 30.5cm (8 x 12”) elliptical shape, this reflector produces an oval pool of light that can be used to create a natural vignette on a background or other areas. Two fitted spring clips allow colour gels to be fitted. BW2560

Accessories

Page 10 of the Bowens BWL-0410 user manual — 5600K ±300K
Page 10 · click to enlarge
Page 10
Bowens BWL-0410 — Specifications Specifications diagram (page 10)
Fig. 22 · Specifications Specifications

Specifications Specifications

Due to our policy of constant product improvement, Bowens International reserves the right to change equipment specifications at any time and without notice.

Dimensions (l x w x h)

User Replaceable Flash Tube

Flash Duration (t=0.5) (Full power)

Typical Recycle Time Full Power, 230V, 50Hz (117V 60Hz)

Guide Number (Full power, 50° Keylite, ISO 100)

Supply Voltage Range 230V (117V)

Part Number (230V) (117V)

365 x 145 x 130mm

2.9Kg

275W Photoflood 250W Halostar

Clear = BW2030 UV = BW2032

Full to 1/32 5 stops

Full / Intermittent / Off

0.81 (1.1) secs

190-250V AC 50Hz (95-130V AC 60Hz)

230V - 5A (F) (117V - 10A (T))

5600K ±300K

BW3700 BW3705

365 x 145 x 130mm

3.4Kg

275W Photoflood 250W Halostar

Clear = BW2030 UV = BW2032

Full to 1/32 5 Stops

Full / Intermittent / Off

1.54 (1.95) secs

190-250V AC 50Hz (95-130V AC 60 Hz)

230V - 5A (F) (117V - 10A (T))

5600K ±300K

BW3710 BW3715

Show 24 more labels / short text on this page
Weight · Recommended Modelling Lamps · Audio Ready Signal · Ready Indication · Modelling Lamp · Flash Power Control · Modelling Power Control · Circuit Protection · Flash Colour Temperature · Sync Voltage · Stored Energy (max) · Unit GMD250 GMD500 · On/Off · On/Off · 100% · Max 275W · 1/1315 · 250Ws · On/Off · On/Off · 100% · Max 275W · 1/925 · 500Ws
Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
ʻEr1ʼFailure to charge correctly at ʻswitch-onʼ. Long sounder if on. This could be due to low mains input or leaky capacitors. After retrying and rechecking a number of times the unit will automatically lock out with the display showing ʻEr1ʼ but with the sounder silenced. p.7
ʻEr2ʼFailure to charge correctly after a flash (sound if on). The most likely cause here is that the tube glowed on. After retrying for a number of times and each time applying a longer glow stop period the unit will automatically lock out with the display showing ʻEr2ʼ but with the sounder silenced. p.7
ʻEr3ʼFailure of the tube to fire (sound if on). p.7
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
12 p.7

Ask about the Bowens BWL-0410

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bowens BWL-0410

Be the first to ask — other owners or our team will answer.

Original document

Bowens BWL-0410 manual PDF

10 pages·655 KB·Camcorder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…