EN
Bowens logo
Official user manual

Bowens Quad 2400 (QUAD2400)

6 pages·183 KB·Portable Generator·PDF·ENDEFRITNLJA
Bowens Quad 2400 (QUAD2400)
Table of Contents 15 sections QUAD2400 GENERATOR INSTRUCTIONS BWL-0350/1 BOWENS INTERNATIONAL LIMITED · i m a g i n g p o w e r · QUAD · QUAD 2400 · … ShowHide
Page 1 of the Bowens Quad 2400 (QUAD2400) user manual — BW-7620
Page 1 · click to enlarge
Page 1

www.bowensinternational.com

Tel+44 (0)1255 422807 Fax: +44 (0)1255 436342

355 Old Road Clacton on Sea Essex CO15 3RH UK

QUAD2400 GENERATOR INSTRUCTIONS BWL-0350/1 BOWENS INTERNATIONAL LIMITED

i m a g i n g p o w e r

QUAD

Bowens Quad 2400 (QUAD2400) — QUAD2400 GENERATOR INSTRUCTIONS BWL-0350/1 BOWENS INTERNATIONAL LIMITED diagram (page 1)
Fig. 1

QUAD 2400

BOWENS

BW-7620

Page 2 of the Bowens Quad 2400 (QUAD2400) user manual — QUAD2400 GENERATOR INSTRUCTIONS BWL-0350/1 BOWENS INTERNATIONAL LIMITED
Page 2 · click to enlarge
Page 2
Page 2 of the Bowens Quad 2400 (QUAD2400) user manual — QUAD2400 GENERATOR INSTRUCTIONS BWL-0350/1 BOWENS INTERNATIONAL LIMITED
Page 3 of the Bowens Quad 2400 (QUAD2400) user manual — Safety Notes
Page 3 · click to enlarge
Page 3
Bowens Quad 2400 (QUAD2400) — QUAD 2400 Introduction diagram (page 3)
Fig. 2 · QUAD 2400 Introduction
Number of Channels Number of HeadSockets Symmetric/Asymmetric Master Power Control Independent Channel Variators Stored Energy (Max.) Flash Power Control Range Guide Number (Full power, 50° Keylite, ISO 100) Typical Recycle Time (Full Power, 230V, 50Hz) Flash Colour Temperature Flash Duration (t=0.5) (One Head, Max. Variator) Power Level Display Flash Voltage Stabilization Supply Voltage Flash Ready Indication Overload Protection Sync Voltage (Max.) Photocell Audio Ready Signal Modelling Lamps Modelling Modes Recommended Flash Head Dimensions (l x w x h) Weight

Dimensions (l x w x h)

Sync Voltage (Max.)

Stored Energy (Max.)

Number of Head Sockets

QUAD 2400 Introduction

  • DO:
  • Switch power off and disconnect from the supply before changing modelling bulb or flash tube.
  • Observe the AC power supply requirements.
  • Ensure that the flash head cable locking rings at the power pack or adapters are fully locked before use.
  • Avoid placing cables where they can be tripped over. Protect from heavy, sharp or hot objects, which may cause damage and replace damaged cables immediately.
  • Unplug the power pack from the electrical outlet when not in use.
  • Remove the power cord by gripping the plug. NEVER pull the cord.
  • Ensure that any extension cord used has a suitable current rating to prevent overheating. NEVER use coiled extension cords.
  • ALWAYS remove the flash head covers before using.

Safety Notes

Show 16 more labels / short text on this page
Weight · Recommended Flash Head · Modelling Modes · Modelling Lamps · Audio Ready Signal · Photocell · Overload Protection · Flash Ready Indication · Supply Voltage · Flash Voltage Stabilization · Power Level Display · Independent Channel Variators · Master Power Control · Symmetric/Asymmetric · Number of Channels · Dear Valued Customer,
Page 4 of the Bowens Quad 2400 (QUAD2400) user manual — Control Panel Guide Warnings Signs and Troubleshooting
Page 4 · click to enlarge
Page 4

Top Control Panel

Carry Handle Channel A Power Level Display

Fast/Slow Switch (Under Handle)

Control Panel Guide Warnings Signs and Troubleshooting

Channel A Variator Channel B Variator

Audio Switch and LED

Bowens Quad 2400 (QUAD2400) — Control Panel Guide Warnings Signs and Troubleshooting diagram (page 4)
Fig. 3 · Control Panel Guide Warnings Signs and Troubleshooti…

Test Button and Ready Indicator

Photocell Switch and LED

Channel B Power Level Display

  • Power Pack Triggers Erratically Check to see if the power pack is being triggered by another flash source by turning the photocell off.
  • Modelling Lamps Are Not Working If all of the modelling lamps are not working, first check to see if the Modelling Thermal Reset Button on the Rear Panel is out. If this is the case, DO NOT RESET IT until you have checked the head(s) for blown bulbs and/or fuses.
  • Control Panel Lights Up But Ready Indicator Does Not Light Up If this happens, first confirm that the AC-line voltage is adequate and within the prescribed limits. Confirm that the Flash Thermal Reset Button on the Rear Panel is pushed in. Under exceptional conditions of use, this may trip. Switch the unit off, wait a minute, push the button in and then switch power on again.
  • Control Panel Does Not Light Up If the Control Panel does not light up when the unit is switched on, first check the AC power-cord connections and check to make sure the AC outlet is working. Under exceptional conditions of use or component failure, the Internal Fuse may blow. This is designed to protect the unit. Report the problem to your local service agent. DO NOT ATTEMPT TO LOCATE AND REPLACE THE INTERNAL FUSE YOURSELF.
  • Overheat Warning The power pack is fitted with a thermostatically controlled fan, but under extreme conditions of use the power pack may still overheat, even with the fan running. Flashing less frequently and/or using the Slow Charge Mode will normally help prevent this from happening. Overheat protection is provided to inhibit charging until the unit has cooled sufficiently to operate normally. The Power Level Displays will flash “Overheat” warning while the overheat condition exists.

If the unit appears to have developed a problem, first establish that it is a genuine internal problem and not a case of normal operation such as overheating. Carry out the following checks to eliminate any external causes. If no obvious problem can be found and replacement of the modelling lamp, flash tube or flash head fuse does not eliminate the problem, then it is likely that an internal problem has developed. Always return the unit to an authorized service centre if a problem is suspected after these checks. UNDER NO CIRCUMSTANCES SHOULD YOU ATTEMPT ANY REPAIR YOURSELF.

Show 6 more labels / short text on this page
Modelling Mode Selector · Head Socket ‘A’ · Sync Sockets · Photocell Window · Overall Power Selector · Head Socket ‘B’
Page 5 of the Bowens Quad 2400 (QUAD2400) user manual — Rear Panel
Page 5 · click to enlarge
Page 5

You are now ready to begin using the generator.

21. Repeat steps 16 to 19 with the Overall Power Selector set to Asymmetric/600 and Asymmetric/300. Confirm that there is an appropriate change of light output with each change of setting. Use a flash meter if possible.
20. Confirm that the head flashes, the power pack recycles and the Ready Indicator lights up.
19. Use the Test Button to discharge the set power into the head.
18. Confirm after a few seconds that the Ready Indicator lights up, the Audio Ready Signal beeps, and the flash head’s Modelling Light is on at Full brightness.
17. This time both numeric displays will show “1200.” The power pack will now charge to this setting.
16. Set the Overall Power Selector to Asymmetric/1200 and both Channel Variators to Full.
15. Switch the power pack off. Plug the head into channel B.
14. Confirm that the head flashes, the power pack recycles and Ready Indicator lights up.
13. Reduce the Channel A Variator setting to -3.0 and confirm that the Modelling Light has dimmed.
12. Repeat steps 8 and 9 with the Overall Power Selector set to Symmetric/1200, Symmetric/600, Asymmetric/1200, Asymmetric/600 and Asymmetric/300. Confirm that there is an appropriate change of light output with each change of setting. Use a flash meter if possible.
11. Confirm that the head flashes, the power pack recycles and Ready Indicator lights up.
10. Use the Test Button to discharge the set power into the head.
9. Confirm after a few seconds that the Ready Indicator lights up, the Audio Ready Signal beeps and the flash head’s Modelling Light is on at Full brightness.
8. Set the Power On/Off Switch to On. The unit will show “2400” on the Channel A display. The pack will now charge to this setting.
7. Connect the power pack to a 230V AC, 50/60Hz outlet using the power cord.
6. Set Audio Switch to On, Photocell Switch to Off and Fast/Slow Switch to Slow.
5. Set the Modelling Mode Selector to Intermittent/Proportional.
4. Set the Overall Power Selector to Symmetric/2400 and the Channel A Variator to Full.
3. Plug the head into the socket of Channel A.
2. Set up a flash head. Be sure the protective cap is removed and the modelling lamp is fitted and switched on.
1. Remove the packaging and ensure that the unit is switched off.

Before first using your power pack or after an extended storage period, it is recommended that the unit be checked for basic operation as follows:

Getting Started Control Panel Guide

3 The Fast/Slow Switch, Overall Power Selector and Modelling Mode Selector are common to both channels.

2 Beneath the Channel Power Level Displays are the Channel Variators. These control the individual power available from the Head Sockets A and B in 1/3 stop increments.

1 The QUAD2400 displays the power available to each channel in watt-seconds on the two red numeric Power Level Displays marked Channel A and Channel B.

NOTES:

Flash Thermal Reset Button

Modelling Thermal Reset Button

AC Inlet 230VAC 50/60Hz 16A

Bowens Quad 2400 (QUAD2400) — NOTES: diagram (page 5)
Fig. 4

The AC Inlet, On/Off Switch and Thermal Reset Buttons are mounted on the rear panel.

Rear Panel

Power On/Off Switch

Page 6 of the Bowens Quad 2400 (QUAD2400) user manual — Triggering System
Page 6 · click to enlarge
Page 6
6. Automatic 100% sets the modelling lamps of the head plugged into the channel with the highest flash power setting to 100% and the modelling lamps of the head plugged into the other channel in proportion to its variator setting.
5. MAX sets all lamps to full brightness.
4. Proportional sets the lamp brightness in proportion to the appropriate Channel Variator setting.
3. Continuous turns the Intermittent mode off.
2. Intermittent extinguishes the lamps when the pack is fired and turns them back on again when the pack is 100% recycled and Ready Indicator lights up. This provides a visual indication that the pack has been successfully triggered and has recycled.
1. Off turns all lamps off.

Modelling Control The Modelling Mode Selector provides a common control for the modelling lamps of all fitted heads. Note that most heads are fitted with a modelling lamp On/Off Switch that overrides the control on the power pack. As well as Off, the pack provides three modelling modes, each available with Intermittent flash indication:

Whenever the power levels are changed, the pack automatically dumps any excess energy. The Test Button will flash while this is occurring. The time for the Ready Indicator to light up can be reduced by using the Test Button to flash the pack.

In general, the Overall Power Selector should be set to the lowest setting and the Channel Variator(s) set to the highest, consistent with the flash power and the distribution between heads required. This method provides the shortest flash duration for a given power output.

The full selected power in Symmetric mode is only available from Channel A, providing that no head is fitted in the Channel B socket. The total power available is shown on the Channel A Power Level Display and is controllable by means of the Channel A Variator only.

The selected power in Asymmetric mode is available independently from each channel whether or not any head is fitted in the other channel. The power available is controllable by using the appropriate Channel Variator and the associated display.

A single Overall Power Selector reduces the pack’s total power by one or two f/stops and individual Channel Variator controls reduce each channel’s power by a further three f/stops in 1/3-stop steps. The Overall Power Selector has settings for both Asymmetric (A/B) and Symmetric (A+B) modes.

Flash Power Control The power pack is divided into two channels, A and B, and each is fitted with one head socket. An LED display for each channel indicates the available power in watt/seconds available at the head fitted to that channel.

Function Overview Function Overview

3. When the Photocell is switched on, the power pack will trigger in response to an external flash of light, if the Ready Indicator is lit. For best results, be sure that the red Photocell window is clearly exposed to the triggering light source.
2. The Test Button will fire the power pack only if the unit is charged and the Ready Indicator is either lit or flashing.
1. An external sync source plugged into either of the Sync Sockets. This will trigger the power pack if the Ready Indicator is lit. The Sync Socket line is nominally +5V and designed for low voltage camera operation. These sockets may also be used with radio and IR triggers to provide a synchronised trigger.

The power pack may be triggered from the following sources:

Using the Slow setting whenever possible will prolong the life of the power supply.

1. Only a poor quality AC supply is available. 2. Several power packs are to share the same supply. 3. Fast recycling is not required.

Fast/Slow Charge The power pack has the facility to adjust the charging times. Turn the Fast/Slow Switch to Slow if:

Photocell A Photocell is provided to trigger the power pack from another flash source or IR Trigger. Turn the Photocell On with the rocker switch. The red LED lights up when the Photocell is on.

Audio Indicator An Audio Ready Signal is provided to beep when the generator is 100% recycled. Turn the Audio Switch On with the rocker switch. The red LED lights up when the Audio is on.

1. Trigger the power pack for test purposes whenever the Test Button is lit. 2. Dump excess energy quickly while the Test Button is flashing. This avoids having to wait a few seconds for the pack to automatically dump energy.

Press the Test Button to:

Test Button and Ready Indicator Light The green Test Button is lit whenever the power pack reaches 100% charge and is ready to be triggered. This light flashes when the pack is automatically dumping excess energy after a power-level adjustment.

Triggering System

Ask about the Bowens Quad 2400 (QUAD2400)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bowens Quad 2400 (QUAD2400)

Be the first to ask — other owners or our team will answer.

Original document

Bowens Quad 2400 (QUAD2400) manual PDF

6 pages·183 KB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…