Instruction/ maintenance manual of the product NCN-90022 Bosch
Go to page of 108
Camera Browser Interface FLEXIDOME corner 9000 MP en Software manual.
.
Camera Brow ser Interface Table of Cont ents | en 3 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 T able of Contents 1 Browser connection 11 1.1 System requirements 11 1.2 Establishing the connection 12 1.2.1 Password protection in camera 12 1.
4 en | Table of Cont ents Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 5 Basic Mode 27 5.1 Device Access 27 5.1.1 Naming 27 5.1.2 Password 27 5.2 Date/Time 29 5.2.1 Device date, time and zone 29 5.2.2 Time server IP address 29 5.
Camera Brow ser Interface Table of Cont ents | en 5 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 7 Web Interface 38 7.1 Appearance 38 7.1.1 Website language 38 7.1.2 Company logo 38 7.1.3 Device logo 38 7.1.4 Show VCA metadata 38 7.
6 en | Table of Cont ents Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 8.3 Picture Settings — Color 46 8.3.1 White balance 46 8.4 Picture Settings — ALC 47 8.4.1 Exposure/frame rate 47 8.4.2 Day/night 47 8.
Camera Brow ser Interface Table of Cont ents | en 7 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 10.1.2 Recording media 61 10.1.3 Activating and configuring storage media 63 10.1.4 Formatting storage media 63 10.1.5 Deactivating storage media 63 10.
8 en | Table of Cont ents Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 11.3.5 Sensitivity 75 11.4 Alarm E-Mail 76 11.4.1 Send alarm e-mail 76 11.4.2 Mail server IP address 76 11.4.3 SMTP user name 76 11.
Camera Brow ser Interface Table of Cont ents | en 9 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 13.2.4 Output name 89 13.2.5 Trigger output 89 14 Network 90 14.1 Network Access 90 14.1.1 Automatic IP assignment 90 14.1.2 IP V4 address 90 14.
10 en | Table of Cont ents Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.3.3 Port 99 14.3.4 Streaming 99 14.3.5 Multicast packet TTL 99 14.4 Image Pos ting 100 14.4.1 JPEG 100 14.5 Accounts 101 14.6 IP V4 filter 102 15 Service 103 15.
Camera Brow ser Interface Brow ser connection | en 11 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 1 Bro wser connection A computer with Microsoft Internet Ex plorer is used to receive live images from the camera, control the camera, and replay stored sequences.
12 en | Bro wser connect ion Camera Bro wser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 1.2 Establishing the connection The camera must have a valid IP address and a compatible subnet mask to operate on your network.
Camera Brow ser Interface Syst em Over view | en 13 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 2 System Ov er view When a connection is established, the Livepage is initially displayed. The application titl e bar displays three items: LIVEPAGE , PLAYBAC K , SETTINGS .
14 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3 Operation via the browser 3.1 L ivepage After the connection is established, the Livepage is initially displayed. It shows the live video image on the right of the browser window.
Camera Brow ser Int er face Operation via the br owser | en 15 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 3.1.2 Status icons Various overlays in the video image provide important status information. The overlays provide the following in formation: Decoding error The frame might show artefacts du e to decoding error s.
16 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Motion flag Indicates that moti on is dectected.
Camera Brow ser Int er face Operation via the br owser | en 17 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 Pre-position To move the camera to a pre-po sition, click one of the buttons numbered one to six. To store the current position of the camera in a pre-position: 1.
18 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Set positions To store the current view: 1. Select a region of interest. 2. Click Set . 3. Click a numb er. To display a pre-set region of in terest, click one of the buttons numbered one to six.
Camera Brow ser Int er face Operation via the br owser | en 19 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 3.1.6 System Log / Event Log The System Log field contains information about the operating status of the camera and the connection.
20 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3.1.9 Running recording program The hard drive icon below the camera images on th e Livepage changes during an automatic recording.
Camera Brow ser Int er face Operation via the br owser | en 21 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 3.2 Playback page Click PLAYBACK to access the Playback page from the Livepage or Settings page. The Playb ack link is only visible if a direct iSCSI or SD card has b een configured for recording.
22 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3.2.2 Expor ting tracks 1. Select a track in the track list. 2. Click the export tab . 3. The start and stop time are fi lled-in for the selected track.
Camera Brow ser Int er face Operation via the br owser | en 23 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 3.2.4 Controlling playback Time bar The time bar below the video im age allows quick orientation. The time interval associated with the seq uence is displayed in the bar in gray.
24 en | Operation via the br owser Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Jump to start of active sequ ence or to previous sequence Jump to start of the next video se quence in the list Bookmarks You can set markers in a seque nce and jump to these directly.
Camera Brow ser Interface Se t tings Over view | en 25 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 4 Se t tings Over view 4.1 Configuration Menu The settings page provides access to the configuration menu which contains all the unit's pa rameters arranged in groups.
26 en | Set tings Over view Camera Bro wser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 4.2 Set tings Navigation To view the current settings: 1. Click the Basic M ode menu or the Advanced Mode menu to expand it. 2. For the Advanced Mode menu, click a menu sub-heading to expand it.
Camera Brow ser Interface Basic Mode | en 27 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 5 Basic Mode 5.1 Device Acce ss 5.1.1 Naming Enter a unique name to assist in identification. This name simplifies the management of multiple devices in more extensive systems.
28 en | Basic Mode Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Password Define or change a separate pass word for each level. Enter the password (19 characters maxi mum) for the selected level. Confirm password Re-enter the new password to ensure that there are no typing mistakes.
Camera Brow ser Interface Basic Mode | en 29 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 5.2 Date/Time 5.2.1 Device date, time and zone If there are multiple devices operating in the system or network, it is important to sync hronize their internal clocks.
30 en | Basic Mode Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 5.3 Network Use the settings on this page to integrate the device into a network. Some changes only take effect after a reboot. In this case, the Set button changes to Set and Reboot .
Camera Brow ser Interface Basic Mode | en 31 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 5.4 Encoder Select a profile for encoding the video signal on stream 1 (this is not a selection of the recording profile).
32 en | Advanced G eneral Se t tings Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 6 Advanced G eneral Se t tings 6.1 Identification 6.1.1 Naming Assign a unique name to assist in identification. This name simplifies the management of multiple devices in more extensive sy stems.
Camera Brow ser Int er face Advanced G eneral Set tings | en 33 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 6.2 Passwor d A password prevents unauthorized access to the device. The device has three authorization levels: service , user , and live .
34 en | Advanced G eneral Se t tings Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 6.3 Dat e/Time 6.3.1 Date format Select the required date format. 6.3.2 Device date / Device time If there are multiple devices operating in your system or network, it is important to sync hronize their intern al clocks.
Camera Brow ser Int er face Advanced G eneral Set tings | en 35 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 First, check the time zone setting. If it is not correct, select the appropriate time zone for the system: 1. Click Set .
36 en | Advanced G eneral Se t tings Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 6.4 Display S tamping Various overlays or stamps in the video im age provide important supplementary inform ation. These overlays can be enabled individually and arrang ed on the image in a clear manner.
Camera Brow ser Int er face Advanced G eneral Set tings | en 37 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 6.4.5 Alarm message Enter the message to be displaye d on the image in the event of an alarm. The maximum text length is 31 characters.
38 en | Web I nterface Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 7 W eb Interface 7.1 Appearance You can adapt the appearance of the web interface and change the website language to meet your requirements.
Camera Brow ser Interface Web Int er face | en 39 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 7.1.6 Select Video player Select the player to be used for live mode viewing. 7.1.7 JPEG size, inte rval and quality Select the size, update interval and quality of the M-JPEG image displayed on the livepage.
40 en | Web I nterface Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 7.2 LIVEP A GE Func tions You can adapt the Livepage functions to meet your requirements. Choose from a vari ety of different options for displaying information and controls.
Camera Brow ser Interface Web Int er face | en 41 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 7.2.6 Show system log The system messages are displayed with the date and time in a field next to the video image and provide information about the establishment and termination of connections, e tc.
42 en | Web I nterface Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 7.3 Logg ing 7.3.1 Save event log Select this option to save event messages in a text file on the local computer. This file can be view ed, edited, and printed with any text editor or standard office sof tware.
Camera Brow ser Interface Camera | en 43 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 8C a m e r a 8.1 Installer Menu 8.1.1 Base frame rate Select the base frame rate for the camera. Note: Shutter times and frame rates are affected by this value.
44 en | Camera Camera Browser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 8.2 Picture Set tings — User Mode A mode is a set of image parame ters that are set in the camera when that mode is selected (Installer menu settings are excluded).
Camera Brow ser Interface Camera | en 45 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 Low light This mode is optimized for suff icient details at low light.
46 en | Camera Camera Browser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 8.3 Picture Set tings — Color Contrast (0...255) Adjust the contrast with the slider from 0 to 255 . Saturation (0...255) Adjust the color saturation wi th the slider from 0 to 255.
Camera Brow ser Interface Camera | en 47 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 8.4 Picture Set t ings — ALC ALC mode Select the mode: – Fluorescent 50 Hz – Fluorescent 60 Hz –O u t d o o r ALC level Adjust the video output level (-15 to 0 to +15).
48 en | Camera Camera Browser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Monochrome (IR) - the IR cut-of f filter is removed, giving full IR sensitivity. Switch level Set the video level at which the camera in Auto mode switches to monochrome operation (-15 to 0 to +15).
Camera Brow ser Interface Camera | en 49 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 8.5 Picture Set t ings — Enhance 8.5.1 Sharpness level Adjusts the black level between -15 and +15. Zero position of slider corresponds to the factory de fault level.
50 en | Camera Camera Browser Int er face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 8.6 Encoder Set tings The Encoder Profile , Encoder Streams , and Encoder Regions settings allow you to adapt the video data transmission characteristics for your oper ating environment (network structure, bandwidth, d ata structures).
Camera Brow ser Interface Camera | en 51 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 8.7 Privacy Masks Four privacy mask areas can be defined. The ac tivated masked areas are filled with the sele cted pattern in live view. 1. Select the pattern to be used for all masks.
52 en | Encoder Set tings Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 9 Encoder Set tings The encoder settings determine the ch aracteristics of the streams generated by the camera.
Camera Brow ser Int er face Encoder Set tings | en 53 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 9.1 Encoder Profile Profiles are rather complex and include a number of parameters that interact with one another, so it is gene rally be st to us e the pre-defined profiles.
54 en | Encoder Set tings Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 9.1.3 Profile name If required, enter a new name for the profile. 9.1.4 Target bit rate To optimize use of the bandwidt h in the network, limit the data rate for the camera.
Camera Brow ser Int er face Encoder Set tings | en 55 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 GOP structure Select the structure you requir e for the Group of Pictures (GOP).
56 en | Encoder Set tings Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3. Set the value for I/P-frame delta QP to the lowest possible value.
Camera Brow ser Int er face Encoder Set tings | en 57 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 9.2 Encoder Str eams 9.2.1 H.264 settings Select H.264 Settings 1. Select a codec algorithm Property for stre am 1 from the drop-down box.
58 en | Encoder Set tings Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 9.2.2 JPEG stream Set the parmeters for the M-JPEG stream. – Select the Resolution . – Select the Max. frame rate in images per second (IPS).
Camera Brow ser Int er face Encoder Set tings | en 59 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 9.3 Encoder Regions 9.3.1 Regions 1. Select one of the eight avai lable regions from the drop- down box. 2. Use the mouse to define the area for that region by dragging the center or sides of the shaded window.
60 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 10 Recording Images can be recorded to an appropriately configured iSCSI system or, for cameras with SD s lots, locally to an SD card. SD cards are the ideal solution for shorter storage times and temporary recordings.
Camera Brow ser Interface Recording | en 61 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 10.1 Storage Management 10.1.1 Device manager Check the Managed by VRM box to let an external Video Recording Manager (VRM) manage all recording.
62 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Local Media An SD card can be used for local recording in cameras with an SD slot. If the SD card is password protected, enter the pas sword into the Password field.
Camera Brow ser Interface Recording | en 63 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 10.1.3 Activating and co nfiguring storage media Available media or iSCSI drives must be transferred to the Managed storage media list, activated, and configured for storage.
64 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 1. Click a storag e medium in the Managed st orage media list to select it. 2. Click Re move below the list. The storage medium is deactivated and removed from the list.
Camera Brow ser Interface Recording | en 65 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 10.2 Recording Profiles A recording profile contains the characteristics of the tracks that are used for recording. These characteristics can be defined for ten different prof iles.
66 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 10.2.1 Recording track selection Standard and alarm recording can be defined f or the two recording tracks. You must first select the track before setting up the standard and alarm recording parameters.
Camera Brow ser Interface Recording | en 67 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 10.2.3 Alarm recording Select a period for the Pre-alarm time from the list box.
68 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 10.4 Recording Scheduler The recording scheduler allows you to link the created recording profiles to the days and times at which the camera's images are to be recorded.
Camera Brow ser Interface Recording | en 69 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 3. Click OK . The selection is removed from the table and the window is closed. 4. Repeat for any other dates to be deleted. 10.4.3 Profile names Change the names of the recording prof iles listed in the Time periods box.
70 en | Recording Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 10.5 Recording Status Details of the recording s tatus are displayed here for information.
Camera Brow ser Interface Alarm | en 71 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 11 Alarm 11.1 Alarm Connectio ns In the event of an alarm, the camera can automatically connect to a pre-defined IP address. The camera can contact up to ten IP addresses in the order listed until a connection is established.
72 en | Alarm Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3. Enter the password in the Destination password field. 4. Set the user password of al l the remote stations to be accessed using this password.
Camera Brow ser Interface Alarm | en 73 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 11.1.10 SSL encryption SSL encryption protects d ata used for establishing a connection, such as the password. By selecting On , only encrypted ports are available for the Remote port parameter.
74 en | Alarm Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 11.2 V ideo Content Analyse s (VCA) The camera has integrated Video Content Analyses (VCA) which detects and analyze changes in the picture using image processing algorithms.
Camera Brow ser Interface Alarm | en 75 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 11.3 Audio Alarm (only for camera s with audio) Alarms can be generated based on audio signals. Configure signal strengths and frequency ra nges so that false alarms, for example, machine noise or ba ckground n oise, are avoided.
76 en | Alarm Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 11.4 Alar m E-Mail Alarm states can be documented by e-mail. The camera automatically sends an e-mail to a user-defined e-mail address. This makes it possible to notify a recipient who does not have a video receiver.
Camera Brow ser Interface Alarm | en 77 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 11.4.7 Attach JPEG from camera Check the box to specify that JPEG images are sent from the camera. 11.4.8 Destination address Enter the e-mail address for al arm e-mails here.
78 en | Alarm Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 11.5 Alar m T ask Editor Editing scripts on this page ov erwrites all settings and en tries on the other alarm pages. This procedure cannot be re versed.
Camera Brow ser Interface Set ting up VCA | en 79 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 12 Set ting up V CA Several VCA configurations are available. – Off – Silent VCA – Profile #1 – Profile #2 – Scheduled – Event triggered 12.
80 en | Set ting up VCA Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 12.2 VCA - Profile s Two profiles can be set up with different VCA configurations. 1. In the VCA configuration drop-down list, select profile 1 or 2 and enter the required settings.
Camera Brow ser Interface Set ting up VCA | en 81 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 12.2.3 Motion detector Motion detection is available for the Motion+ analysis type. For the detector to function, the fo llowing conditions must be met: – Analysis must be activated.
82 en | Set ting up VCA Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Selecting the area Select the areas of the image to be monitored by the motion detector. The video image is su bdivided into square sensor fields.
Camera Brow ser Interface Set ting up VCA | en 83 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 the triggering conditio n still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered.
84 en | Set ting up VCA Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems Reference check Save a reference image that can be continuously compared with the current video image. If th e current video image in the marked areas differs from the reference image, an alarm is triggered.
Camera Brow ser Interface Set ting up VCA | en 85 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 1. Click Select Area to configure the sensor fields . A new window opens. 2. If necessary, click Clear All first to clear the current selection (fields marked yellow).
86 en | Set ting up VCA Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 12.3 VCA - Schedule d A scheduled configuration allows you to link a VCA profile with the days and times at which the vi deo content analysis is to be active.
Camera Brow ser Interface Set ting up VCA | en 87 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 Deleting Holidays Delete defined holidays at any time: 1. Click Delete . A new window opens. 2. Click the date to delete. 3. Click OK .
88 en | Set ting up VCA Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 12.4 VCA - Event trigger ed This configuration allo ws you to stipulate that the video content analysis is only to be activate d when triggered by an event.
Camera Brow ser Interface Interfaces | en 89 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 13 Interfaces 13.1 Alarm input Configure the alarm triggers for the camera. Select N.C. (Normally Closed) if the al arm is to be triggered by closing the contact.
90 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14 Ne twork 14.1 N e twork Acce ss The settings on this page are used to integrate the device into a network. Some changes only take effect after a reboot.
Camera Brow ser Interface Network | en 91 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 14.1.3 IP V6 address IP address Enter the desired IP address fo r the camera. The IP address must be valid for the network. Prefix length Enter the appropriate prefix le ngth for the set IP address.
92 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.1.8 HTTPS browser port To limit browser access to encr ypted connections, choose an HTTPS port from the list. The standard HTTPS port is 443.
Camera Brow ser Interface Network | en 93 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 14.1.13 iSCSI MSS [Byte] Specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on th e network structure.
94 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the device, click the Register button.
Camera Brow ser Interface Network | en 95 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 14.2 Adv anced The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot .
96 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.2.2 Authentication (802.1x) To configure Radius server auth entication, connect the camera directly to a computer using a ne twork cable.
Camera Brow ser Interface Network | en 97 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 define a Post Alarm Time over wh ich this priority is maintained. 14.2.7 Cloud-based services The User Mode de termines how the camera communicates with the Bosch Cloud-based Security and Services.
98 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.3 Multicast The camera can enable multiple receivers to receive the video signal simultaneously.
Camera Brow ser Interface Network | en 99 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances. 14.3.3 Port Enter the port address for the stream here.
100 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.4 Image Posting A target account must first be defined to use JPEG and Best faces posting and for the export of recordings. 14.4.1 JPEG Send individual JPEG images to a target account at specific intervals.
Camera Brow ser Interface Network | en 101 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 14.5 Accounts Four separate accounts can be defined fo r posting and recording export. Type Select either FTP or Dropbox for the account type.
102 en | Network Camera Brow ser Interface AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 14.6 IP V4 f ilter To restrict the range of IP addres ses within which you can actively connect to the device, fill-in an IP address and mask.
Camera Brow ser Interface Ser vice | en 103 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 15 Ser vice 15.1 Maintenance 15.1.1 Update server The address of the Bosch update server appears in the address box. 1. Click Check to make a connecti on to this server.
104 en | Ser vice Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems 3. Click Upload to begin transferring the file to the device. The progress bar allows moni toring of the transfer. The new firmware is unpacked and the Flash memory is reprogrammed.
Camera Brow ser Interface Ser vice | en 105 Bosch Security Systems Software manual AM18-Q0649 | v5.8 | 2013.06 1. Enter the full path of the file to upload or click Browse... to locate the file. 2. Click Upload to start the file transfer. Once all files have been successf ully uploaded, the device must be rebooted.
106 en | Ser vice Camera Brow ser Inte r face AM18-Q0649 | v5.8 | 2013.06 Software manual Bosch Security Systems.
.
Bosch Security Systems www.boschsecurity.com © Bosch Security Systems, 2013.
An important point after buying a device Bosch NCN-90022 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bosch NCN-90022 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bosch NCN-90022 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bosch NCN-90022 you will learn all the available features of the product, as well as information on its operation. The information that you get Bosch NCN-90022 will certainly help you make a decision on the purchase.
If you already are a holder of Bosch NCN-90022, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bosch NCN-90022.
However, one of the most important roles played by the user manual is to help in solving problems with Bosch NCN-90022. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bosch NCN-90022 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center