EN
Panasonic logo
Official user manual

Panasonic CU-E9PKE

64 pages·6.1 MB·Air Conditioner·PDF·ENJA
Panasonic CU-E9PKE
Table of Contents 65 sections Operating Instructions Air Conditioner · CU-2E15PBE CU-2E18PBE CU-3E18PBE CU-4E23PBE CU-4E27PBE CU-5E34PBE · F568894 · Provide maximum comfort, clean air and optimise energy saving · … ShowHide
Page 1 of the Panasonic CU-E9PKE user manual — F568894
Page 1 · click to enlarge
Page 1

Operating Instructions Air Conditioner

Panasonic CU-E9PKE — Operating Instructions Air Conditioner diagram (page 1)
Fig. 1 · Operating Instructions Air Conditioner

Operating Instructions Air Conditioner 2-11

Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

Nederlands Italiano Deutsch Español Français English

Model No. Indoor Unit INVERTER DELUXE XE series E series CS-XE7PKEW CS-XE9PKEW CS-XE12PKEW CS-XE15PKEW CS-XE18PKEW CS-XE21PKEW

Comment utiliser l’appareil Climatiseur 12-21

Nous vous remercions d’avoir porté votre choix sur un climatiseur Panasonic. Instructions d’installation jointes. Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.

CS-E7PKEW CS-E9PKEW CS-E12PKEW CS-E15PKEW CS-E18PKEW CS-E21PKEW CS-E24PKEW ME series CS-ME5PKE

Instrucciones de funcionamiento Climatizador de aire 22-31

Muchas gracias por elegir una unidad de aire acondicionado Panasonic. Incluye instrucciones de instalación. Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.

Outdoor Unit Single Split Multi Split CU-E7PKE CU-E9PKE CU-E12PKE CU-E15PKE CU-E18PKE CU-E21PKE CU-E24PKE

CU-2E15PBE CU-2E18PBE CU-3E18PBE CU-4E23PBE CU-4E27PBE CU-5E34PBE

Wir danken Ihnen für den Kauf Ihres Panasonic- Klimageräts. Die Montageanleitung liegt dem Gerät bei. Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.

Istruzioni di funzionamento Condizionatore d’aria 42-51

Grazie per aver acquistato un climatizzatore Panasonic. Istruzioni d’installazione allegate. Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro.

Hartelijk dank voor de aanschaf van de Panasonicairconditioner. Installatie-instructies bijgevoegd. Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik.

F568894

Bedienungsanleitung Klimagerät 32-41 · Handleiding Airconditioner 52-61

Page 2 of the Panasonic CU-E9PKE user manual — CU-4E23PBE, CU-4E27PBE, CU-5E34PBE)
Page 2 · click to enlarge
Page 2

Provide maximum comfort, clean air and optimise energy saving

ECONAVI and AUTO COMFORT Equipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, and keeps the room consistently comfortable with minimum energy consumption. Furthermore, the sunlight sensor detects the sunlight intensity and helps control heating/cooling temperatures to provide optimum comfort. See “To learn more...” for details.

nanoe-G Deactivates harmful micro-organisms such as viruses, bacteria, etc. to keep air clean. It also deactivates viruses and bacteria on the fi lter to keep inside of the unit clean.

Panasonic CU-E9PKE — Provide maximum comfort, clean air and optimise energy saving diagram (page 2)
Fig. 2 · Provide maximum comfort, clean air and optimise ener…

Multi air conditioner system Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. • For complete product features, please refer catalogue.

Indoor units

Panasonic CU-E9PKE — Indoor units diagram (page 2)
Fig. 3 · Indoor units
  • Indoor units
  • It is possible to operate the indoor units individually or simultaneously. The priority of operation is placed on the fi rst unit that turned on.
  • During operation, HEAT and COOL modes cannot activate at the same time for different indoor units.
  • The power indicator blinks to indicate the indoor unit is standing by for a different operation mode.

Outdoor unit ( CU-2E15PBE, CU-2E18PBE, CU-3E18PBE,

CU-4E23PBE, CU-4E27PBE, CU-5E34PBE)

Page 3 of the Panasonic CU-E9PKE user manual — Provide maximum comfort, clean air and optimise energy saving
Page 3 · click to enlarge
Page 3
Page 3 of the Panasonic CU-E9PKE user manual — Provide maximum comfort, clean air and optimise energy saving
Page 4 of the Panasonic CU-E9PKE user manual — Power supply
Page 4 · click to enlarge
Page 4

Safety precautions

To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

This sign warns of death or serious injury.

WARNING

This sign warns of injury or damage to property.

CAUTION

Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.

The instructions to be followed are classifi ed by the following symbols:

This symbol denotes an action that is PROHIBITED.

Confi rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.

Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.

These symbols denote actions COMPULSORY.

Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not expose yourself directly to cold air for a long period to avoid excess cooling.

Do not sit or step on the unit, you may fall down accidentally.

Air inlet Air inlet

Remote control

Air outlet Air outlet

Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.

Air inlet Air inlet

Power supply

Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.

Air outlet Air outlet

Show 4 more labels / short text on this page
Power supply · Indoor unit · Remote control · Outdoor unit
Page 5 of the Panasonic CU-E9PKE user manual — Power supply
Page 5 · click to enlarge
Page 5
  • To prevent overheating, fi re or electric shock:
  • Do not share the same power outlet with other equipment.
  • Do not operate with wet hands.
  • Do not over bend the power supply cord.
  • Do not operate or stop the unit by inserting or pulling out the power plug.

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.

Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.

If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard.

Do not expose plants or pet directly to airfl ow to avoid injury, etc.

Do not touch the sharp aluminium fi n, sharp parts may cause injury.

It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.

Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.

  • To prevent overheating, fi re or electric shock:
  • Insert the power plug properly.
  • Dust on the power plug should be periodically wiped with a dry cloth.

Do not install the unit in oily and smoky areas to prevent damage to the unit.

Do not dismantle the unit for cleaning purpose to avoid injury.

  • Stop using the product if any abnormality/ failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure
  • The ELCB trips frequently.
  • Burning smell is observed.
  • Abnormal noise or vibration of the unit is observed.
  • Water leaks from the indoor unit.
  • Power cord or plug becomes abnormally hot.
  • Fan speed cannot be controlled.
  • The unit stops running immediately even if it is switched on for operation.
  • The fan does not stop even if the operation is stopped. Contact your local dealer immediately for maintenance/repair.

Do not step onto an unstable bench when cleaning the unit to avoid injury.

Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.

Do not open window or door for long time during COOL/DRY mode operation.

Prevent water leakage by ensuring drainage pipe is: - Connected properly, - Kept clear of gutters and containers, or - Not immersed in water

After a long period of use or use with any combustible equipment, aerate the room regularly.

This equipment must be earthed to prevent electrical shock or fi re.

After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.

Prevent electric shock by switching off the power supply and unplug: - Before cleaning or servicing, - When extended non-use, or - During abnormally strong lightning activity.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.

  • To prevent malfunction or damage of the remote control:
  • Remove the batteries if the unit is not going to be used for a long period of time.
  • New batteries of the same type must be inserted following the polarity stated.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.

Power supply

Do not disconnect the plug by pulling the cord to prevent electric shock.

Safety precautions

Page 6 of the Panasonic CU-E9PKE user manual — Auto OFF/ON button
Page 6 · click to enlarge
Page 6

How to use

Single Single split system

Multi Multi split system

Panasonic CU-E9PKE — How to use diagram (page 6)
Fig. 4 · How to use

TIMER AUTO COMFORT NANOE-G POWERFUL QUIET POWER

(Green) (Green) (Blue) (Orange) (Orange) (Orange) (Green)

To optimise energy saving

Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 5 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 6 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 7 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 8 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 9 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 10 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 11 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 12 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 13 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 14 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 15 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 16 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 17 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 18 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 19 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 20 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 21 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 22 · To optimise energy saving
Panasonic CU-E9PKE — To optimise energy saving diagram (page 6)
Fig. 23 · To optimise energy saving

MODE

To select operation mode

AUTO - For your convenience HEAT - To enjoy warm air COOL - To enjoy cool air DRY - To dehumidify the environment

Sunlight sensor and remote control receiver

MILD DRY

COOLING To improve humidity and

AUTO

FAN SPEED

moisture level

HEAT COOL

  • Single
  • This operation reduces air dryness and provides you with a comfortable living environment during COOL mode only.
  • When vertical airfl ow direction is set to AUTO, it stops at lower position to avoid cold air contact. However, you can adjust the louver direction manually.

DRY

AIR SWING

MILD

DRY

OFF/ON

OFF/ON

AUTO COMFORT

MODE

NANOE-G

Press and hold for approximately 10 seconds to show temperature setting in °C or °F.

MILD DRY

COOLING

TEMP

TEMP

Multi • Function not applicable.

POWERFUL/

QUIET

AIR SWING FAN SPEED

POWERFUL/

QUIET To switch between powerful & quiet

Press to restore the remote control to default setting.

QUIET POWERFUL NORMAL

POWERFUL: To reach temperature quickly

AC RC

SET CHECK CLOCK RESET

CHECK CLOCK

POWERFUL

Not used in normal operations.

Single • This operation stops automatically after 20 minutes.

Multi • Press the button again or turn OFF the unit to stop this operation. QUIET: To enjoy quiet operation

FAN SPEED

To select fan speed

( Remote control display )

QUIET • This operation reduces airfl ow noise.

  • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.

Auto OFF/ON button

Panasonic CU-E9PKE — Auto OFF/ON button diagram (page 6)
Fig. 24 · Auto OFF/ON button

Use when remote control is misplaced or a malfunction occurs. Raise the front panel: 1. Press the button once to use in AUTO mode. 2. Press and hold the button until you hear 1 beep, then release to use in forced COOL mode. 3. Repeat step 2. Press and hold the button until you hear 2 beeps, then release to use in forced HEAT mode. • Press the button again to turn off.

Show 4 more labels / short text on this page
Indicator · Human activity sensor · Remote control display · /
Page 7 of the Panasonic CU-E9PKE user manual — ( Remote control display )
Page 7 · click to enlarge
Page 7

See "To learn more..." for details.

Panasonic CU-E9PKE — AUTO COMFORT To maximise comfort diagram (page 7)
Fig. 25 · AUTO COMFORT To maximise comfort
Toset the tim 2 s to timets of ON an turn ON or OF es. 1 2 TIMER ON 1 2 OFF C

AUTO COMFORT To maximise comfort

Panasonic CU-E9PKE — AUTO COMFORT To maximise comfort diagram (page 7)
Fig. 26 · AUTO COMFORT To maximise comfort
Panasonic CU-E9PKE — AUTO COMFORT To maximise comfort diagram (page 7)
Fig. 27 · AUTO COMFORT To maximise comfort

NANOE-G • nanoe-G starts automatically when the unit is turned on with

  • Can be activated even when the unit is turned off. In this condition, the unit will operate as a fan with AUTO fan speed and louver swing.

Multi • This operation cannot be performed or will be stopped if other indoor unit is activating HEAT mode.

To deactivate viruses/bacteria on the fi lter

  • NANOE-G POWER
  • After the unit is turned off, the nanoe-G in-fi lter deactivation may activate up to 150 minutes. Turning on the unit cancels this operation.
  • To disable this operation in the future, press and hold

until a short beep sound is heard. This will not disable the nanoe-G to purify the air. • To restore the nanoe-G in-fi lter deactivation, press and

NANOE-G

Panasonic CU-E9PKE — NANOE-G diagram (page 7)
Fig. 28

NANOE-G

CANCEL. • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing

ON or OFF to select respective or then press

  • SET .
  • The nearest timer setting will be displayed and will activate in sequence.
  • When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
  • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Quick guide.

( Remote control display )

  • Keeps the room ventilated.
  • In COOL/DRY mode, if AUTO is set, the louver swings left/right and up/down automatically.
  • In HEAT mode, if AUTO is set, the horizontal louver is fi xed at the predetermined position. The vertical louver swings left/right after the temperature rises.
  • Do not adjust the louver by hand.
Panasonic CU-E9PKE — ( Remote control display ) diagram (page 7)
Fig. 29 · ( Remote control display )
  • Can be activated in all modes and can be cancelled by pressing the respective button again.
  • Cannot be selected at the same time.
  • Cannot be activated during MILD DRY COOLING.
Page 8 of the Panasonic CU-E9PKE user manual — COOL/DRY
Page 8 · click to enlarge
Page 8

To learn more...

Single Single split system

Multi Multi split system

Operation mode

AUTO : During operation mode selection the POWER indicator blinks.

Single • Unit selects operation mode every 10 minutes according to setting temperature and room temperature.

Multi • Unit selects operation mode every 3 hours according to setting temperature, outdoor temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY : Unit operates at low fan speed to give a gentle cooling operation.

nanoe-G in-fi lter deactivation

Depending on the unit’s accumulated operation time, nanoe-G in-fi lter deactivation may activate only once a day after the unit turned off.

To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This process only applicable when the unit is operated in COOL/DRY mode before turned off. Then, nanoe-G deactivates viruses/bacteria on the fi lter for 2 hours with fan stopped and louver closed.

Do not turn off the power supply during this operation. After power failure, this operation will not resume.

ECONAVI and AUTO COMFORT

AUTO COMFORT or Note

AIR SWING When manual AIR SWING is selected, the ECONAVI and AUTO COMFORT operations will be cancelled. The unit will start to initialise (for approximately 1 minute)

The human activity sensor and the sunlight sensor will start to detect.

Human activity sensor operation

ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.

Low activity Normal activity Human Mode

COOL/DRY

+2 °C +1 °C

HEAT

-2 °C -2 °C

AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human

comfortable consistently.

Low activity +1 °C +0.3 °C+2 °C +1 tap*-1 °C -2 °C +1 tap-2 °C ”0HGLXP)DQ

COOL/DRY

HEAT

ECONAVI and AUTO COMFORT

Precise control of temperature during low activity to maximise energy saving.

Low activity Human Mode

ECONAVI and AUTO COMFORT take advantage of the human nature that human being takes time to feel the temperature rise during low activity level; the unit adjusts temperature to maximise energy saving without sacrificing the comfort.

* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached. ** During human absence, maximum fan speed for COOL/DRY mode is medium fan.

Show 5 more labels / short text on this page
High activity Absent · Set temperature · Set temperature · Set Fan Speed · Set temperature COOL/DRY
Page 9 of the Panasonic CU-E9PKE user manual — +1 °C
Page 9 · click to enlarge
Page 9

The human activity sensor will also scan for area of heat source and movement in a room.

  • Based on area activeness horizontal airfl ow direction louver will adjust either fi x at predetermined position or swing left/right periodically.

120º

  • The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature range, etc.
  • The human activity sensor may: - mistakenly detect an object with heat source & movement similar to human, such as pets, etc. - mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
  • Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection area. They may cause sensor malfunction.

To learn more...

Sunlight Sensor operation

ECONAVI is activated, the unit maintains set temperature until a high sunlight intensity is detected. The sunlight sensor detects sunlight intensity during weather or day/night changes, and the unit adjusts temperature.

ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.

+1 °C

COOL/DRY

-1 °C -1 °C

  • In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
CU-E7PKE, CU-E9PKE, Indoor Outdoor CU-E12PKE, CU-E15PKE, DBT WBT DBT WBT CU-E18PKE, CU-E21PKE, CU-E24PKE Max. 32 23 43 26 COOL Min. 16 11 -10 - Max. 30 - 24 18 HEAT Min. 16 - -15 -16 °C (temperature) CU-E7PKE, CU-E9PKE, CU-E12PKE, CU-E15PKE, CU-E18PKE, CU-E21PKE, CU-E24PKEIndoorOutdoor DBTWBTDBTWBT COOLMax.32234326 Min.1611-10- HEATMax.30-2418 Min.16--15-16 °C (temperature) Multi split outdoor unit CU-2E15PBE, CU-2E18PBE, Indoor Outdoor CU-3E18PBE, CU-4E23PBE, DBT WBT DBT WBT CU-4E27PBE, CU-5E34PBE Max. 32 23 46 26 COOL Min. 16 11 -10 - Max. 30 - 24 18 HEAT Min. 16 - -15 -16 °C (temperature) CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E23PBE, CU-4E27PBE, CU-5E34PBEIndoorOutdoor DBTWBTDBTWBT COOLMax.32234626 Min.1611-10- HEATMax.30-2418 Min.16--15-16 °C (temperature)
Panasonic CU-E9PKE — +1 °C diagram (page 9)
Fig. 30
Show 4 more labels / short text on this page
Detection area · 7m · Ambient condition Mode · Set temperature HEAT
Page 10 of the Panasonic CU-E9PKE user manual — Remove the front panel
Page 10 · click to enlarge
Page 10

Cleaning instructions

To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorised dealer.

Indoor unit

Aluminium fi n Front panel

  • Switch off the power supply and unplug before cleaning.
  • Do not touch the aluminium fi n, sharp parts may cause injury.
  • Do not use benzine, thinner or scouring powder.
  • Use only soap ( pH 7) or neutral household detergent.
  • Do not use water hotter than 40 °C.

Indoor unit Wipe the unit gently with a soft, dry cloth.

  • nanoe-G Generator Every 6 months
  • Clean with dry cotton bud.
  • Do not touch during operation.

Human activity sensor Do not hit or violently press or poke it with a sharp object. This can lead to damage and malfunction.

  • Air fi lters Every 2 weeks
  • Wash/rinse the fi lters gently with water to avoid damage to the fi lter surface.
  • Dry the fi lters thoroughly under shade, away from fi re or direct sunlight.
  • Replace any damaged fi lters.

Front panel Wash gently and dry.

Remove the front panel

Remove air fi lter Attach air fi lter

Close it securely

Insert at both sides 1

Insert into the unit

Press both ends of the front panel 3

  • For seasonal inspection after extended non-use
  • Checking of remote control batteries.
  • No obstruction at air inlet and air outlet vents.
  • Use Auto OFF/ON button to select COOL/ HEAT operation. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:
  • COOL: ≥8 °C HEAT: ≥14 °C For extended non-use
  • Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth.
  • Turn off the power supply and unplug.
  • Remove the remote control batteries.

For CS-XE18PKEW, CS-XE21PKEW, CS-E18PKEW, CS-E21PKEW, CS-E24PKEW: Press at center of the front panel.

Show 6 more labels / short text on this page
Human activity sensor · nanoe-G Generator · Air fi lters · Pull out · Raise · Close down 2
Page 11 of the Panasonic CU-E9PKE user manual — Troubleshooting
Page 11 · click to enlarge
Page 11

Troubleshooting

The following symptoms do not indicate malfunction.

SymptomCause Mist emerges from indoor unit.• Condensation effect due to cooling process. Water fl owing sound during operation.• Refrigerant fl ow inside the unit. The room has a peculiar odour.• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour. Airfl ow continues even after operation has stopped.• Extraction of remaining heat from the indoor unit (maximum 30 seconds). Operation is delayed a few minutes after restarting.• The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes. TIMER indicator is always on.• The timer setting repeats daily once set. POWER indicator blinks during HEAT mode with no warm air supply (and louver is closed).• The unit is in defrost mode (and AIR SWING is set to AUTO). Indoor fan stops occasionally during heating operation.• To avoid unintended cooling effect. POWER indicator blinks before the unit is switched on.• This is a preliminary step in preparation for the operation when the ON timer has been set. Cracking sound during operation.• Changes of temperature caused the expansion/ contraction of the unit.

Cleaning instructions / Troubleshooting

Check the following before calling for servicing.

SymptomCheck Operation in HEAT/COOL mode is not working effi ciently.• Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. Noisy during operation.• Check if the unit has been installed at an incline. • Close the front panel properly. Remote control does not work. (Display is dim or transmission signal is weak.)• Insert the batte • Replace weakries correctly. batteries. The unit does not work.• Check if the cir • Check if timerscuit breaker is have been settripped. . The unit does not receive the signal from the remote control.• Make sure the • Certain fl uores transmitter. Plereceiver is not cent lights may ase consult auobstructed. interfere with signal thorised dealer. NON SERVICEABLE CRITERIAS The unit stops and the TIMER indicator blinks. TURN OFF POWER SUPPLY AND Use remote control to retrieve error code. UNPLUG then please consult authorised 1 Press for TIMER 2 Press until you dealer under the following conditions: 5 seconds ON SET hear beep sound, • Abnormal noise during operation. 1 2 3 then write down • Water/foreign particles have entered the 3 Press for OFF CANCEL the error code remote control. 5 seconds AC RC 4 Turn the unit off • Water leaks from Indoor unit. to quit SET CHECK CLOCK RESET and reveal the • Circuit breaker switches off frequently. checking error code to • Power cord becomes unnaturally warm. authorised dealers and the TI to retrieve error TIMER ON 1 OFF SETSE 2 3 CAN AC R CHECK CLOCK RESET
  • For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Mist emerges from indoor unit.• Condensation effect due to cooling process. p.11
Water fl owing sound during operation.• Refrigerant fl ow inside the unit. p.11
The room has a peculiar odour.• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. p.11
Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour. p.11
Airfl ow continues even after operation has stopped.• Extraction of remaining heat from the indoor unit (maximum 30 seconds). p.11
Operation is delayed a few minutes after restarting.• The delay is a protection to the unit’s compressor. p.11
Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes. p.11
TIMER indicator is always on.• The timer setting repeats daily once set. p.11
POWER indicator blinks during HEAT mode with no warm air supply (and louver is closed).• The unit is in defrost mode (and AIR SWING is set to AUTO). p.11
Indoor fan stops occasionally during heating operation.• To avoid unintended cooling effect. p.11
POWER indicator blinks before the unit is switched on.• This is a preliminary step in preparation for the operation when the ON timer has been set. p.11
Cracking sound during operation.• Changes of temperature caused the expansion/ contraction of the unit. p.11
Operation in HEAT/COOL mode is not working effi ciently.• Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. p.11
Noisy during operation.• Check if the unit has been installed at an incline. • Close the front panel properly. p.11
Remote control does not work. (Display is dim or transmission signal is weak.)• Insert the batte • Replace weak p.11
The unit does not work.• Check if the cir • Check if timers p.11
The unit does not receive the signal from the remote control.• Make sure the • Certain fl uores transmitter. Ple p.11
NON SERVICEABLE CRITERIAS The unit stops and the TIMER indicator blinks. TURN OFF POWER SUPPLY AND Use remote control to retrieve error code. UNPLUG then please consult authorised 1 Press for TIMER 2 Press until you dealer under the following conditions: 5 seconds ON SET hear beep sound, • Abnormal noise during operation. 1 2 3 then write down • Water/foreign particles have entered the 3 Press for OFF CANCEL the error code remote control. 5 seconds AC RC 4 Turn the unit off • Water leaks from Indoor unit. to quit SET CHECK CLOCK RESET and reveal the • Circuit breaker switches off frequently. checking error code to • Power cord becomes unnaturally warm. authorised dealer p.11

Ask about the Panasonic CU-E9PKE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic CU-E9PKE

Be the first to ask — other owners or our team will answer.

Original document

Panasonic CU-E9PKE manual PDF

64 pages·6.1 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…