Panasonic Air Conditioner (CS-E9DKEW)

98 pages·9.2 MB·Air Conditioner·PDF·ENDEFRITNLJA
Panasonic Air Conditioner (CS-E9DKEW)
Table of Contents 80 sections CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE · 2 Functions · 2.1. Remote Control · OFF/ON · … ShowHide
CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKEp.32 Functionsp.32.1. Remote Controlp.3OFF/ONp.3Operation OFF / ONp.3MODEp.3Room Temperature Settingp.3TIMERp.3ONp.3OFFp.3POWERFULp.3Powerful Mode Operationp.3Time / Timer Settingp.3SETp.3Ion Mode Operation OFF / ONp.3CANCELp.3Timer Operation Set / Cancelp.3AIR SWINGp.3Airflow Direction Controlp.3CLOCKp.3Clock Settingp.3CHECKp.3Check Pointp.32.2. Indoor Unitp.4Automatic Operation Switchp.4Four Operation Modesp.4Automatic and 5 Manual Indoor Fan Speedsp.4Automatic and 5 Manual Vertical Airflow Directionsp.4Automatic and 5 Manual Horizontal Airflow Directionsp.4Powerful Modep.4Operation Indication Lamps (LED)p.4Quiet Modep.4Ionizer Controlp.4Delay ON Timer and OFF Timerp.4Automatic Restart Controlp.4Microcomputer-controlled Room Temperature Controlp.4Breakdown Self Diagnosis Functionp.5Low Pressure Control (Gas Leakeage Detection)p.5Indoor Power Relay Controlp.5Deodorizing Controlp.5Anti-Dew Formation Controlp.5Anti Freezing Controlp.5Anti-Cold Draft Controlp.5Hot Startp.5Intake Air Temperature Controlp.5High Pressure Controlp.5Deice Operationp.52.3. Outdoor Unitp.6Time Delay Safety Controlp.630 seconds Forced Operationp.6Overload Protection Controlp.6Total Running Current Controlp.6Compressor Overheating Prevention Controlp.6IPM (Power Transistor) Overheating Protection Controlp.6Low Operation Frequency Protection Controlp.6Mininum Operation Frequency Protection Controlp.6Outdoor Air Temperature Controlp.6Standby Controlp.63 Product Specificationsp.73.1. CS-E9DKEW CU-E9DKEp.7SIDE VIEWp.7TOP VIEWp.7INTAKEp.73.2. CS-E12DKEW CU-E12DKEp.94 Dimensionsp.114.1. Indoor Unit & Remote Controlp.114.1.1. CS-E9DKEW CS-E12DKEWp.114.2. Outdoor Unitp.124.2.1. CU-E9DKE CU-E12DKEp.125 Refrigeration Cycle Diagramp.136 Block Diagramp.147 Wiring Diagramp.158 Operation Detailsp.168.1. Basic Functionp.168.1.1. Internal Setting Temperaturep.16X +0.5 Xp.16X -1.0 5p.165 0.0 Xp.1620 -2.0 Xp.1620 -1.0 Xp.16
Page 1 of the Panasonic Air Conditioner (CS-E9DKEW) user manual
Page 1 · click to enlarge
Page 1
Panasonic Air Conditioner (CS-E9DKEW) diagram (page 1)
Fig. 1

11 Installation And Servicing Air Conditioner Using R410A 61

© 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.

Page 2 of the Panasonic Air Conditioner (CS-E9DKEW) user manual
Page 2 · click to enlarge
Page 2
Panasonic Air Conditioner (CS-E9DKEW) diagram (page 2)
Fig. 2

18.4. Print Pattern Indoor Unit Printed Circuit Board 97

18.5. Print Pattern Outdoor Unit Printed Circuit Board 98

− Automatic air swing and manual adjusted by Remote

Inactive various harmful airbone elements including allergens, viruses and bacteria.

Generated supersonic waves enhance the ability to collect dust and dirt in the air.

Page 3 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CHECK
Page 3 · click to enlarge
Page 3

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 3)
Fig. 3

2 Functions

2.1. Remote Control

Panasonic Air Conditioner (CS-E9DKEW) — 2 Functions diagram (page 3)
Fig. 4 · 2 Functions

Indoor Fan Speed Selection FAN SPEED

  • Low
  • Medium-
  • Medium
  • Medium+
  • High
  • AUTO Automatic Fan Speed FAN

OFF/ON

Operation OFF / ON

MODE

TEMP Operation Mode Selection

Room Temperature Setting

  • a Automatic Operation
  • HEAT Heating Operation
  • COOL Cooling Operation
  • DRY Soft Dry Operation
  • Increase or decrease set temperature (16°C to 30°C)

TIMER

ON

OFF

  • 24-hour, OFF / ON Real Timer Setting. Timer Operation Selection

POWERFUL

Powerful Mode Operation

Quiet Mode Operation OFF / ON QUIET

Time / Timer Setting

  • Hours and minutes setting.

SET

Ion Mode Operation OFF / ON

CANCEL

Timer Operation Set / Cancel

AIR SWING

  • ON Timer and OFF Timer setting and cancellation.

Airflow Direction Control

CLOCK

Clock Setting

  • Vertical Automatic Airflow Direction Control and Manual Airflow Direction Control (5 stages of adjustment).
  • Horizontal Automatic Airflow Direction Control and Manual Airflow Direction Control (5 stages of adjustment).
  • Current time setting.

CHECK

Check Point

  • Breakdown self diagnosis function.
  • Clear memory data.

∧ ∨ · Reset Point RESET

Page 4 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — Microcomputer-controlled Room Temperature Control
Page 4 · click to enlarge
Page 4

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2.2. Indoor Unit

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 4)
Fig. 5

Automatic Operation Switch

Four Operation Modes

  • Press for < 5s to run Automatic Operation. (Used when the remote control cannot be used.)
  • Press continuously for 5s and < 8s to run Forced Cooling Operation.
  • Press continuously for 8s and < 11s to run Forced Heating Operation.
  • Press continuously for 11s and < 16s to change different remote controlling setting (A ↔ B Mode).
  • Press continuously for 16s or < 21s to switch OFF / ON Remote Control Receiving Sound or H14 Abnormality Detection Mode.
  • Automatic, Heating, Cooling and Soft Dry Operation.

Automatic and 5 Manual Indoor Fan Speeds

Automatic and 5 Manual Vertical Airflow Directions

Automatic and 5 Manual Horizontal Airflow Directions

Powerful Mode

Operation Indication Lamps (LED)

  • For quick cooling or heating.
  • POWER (Green) ........ Lights up in

operation, blinks in Automatic Operation Mode judging and Hot Start operation. • TIMER (Orange) Lights up in Timer

Quiet Mode

  • To provide quiet operation.

Ionizer Control

Setting. Blinks in Self Diagnosis Control. • QUIET (Orange) Lights up in Quiet

  • Ionizer control for generate negative ion in discharge air.

Delay ON Timer and OFF Timer

  • Mode Operation.
  • POWERFUL (Orange) ..... Lights up when Powerful Mode is selected.
  • (Green) .............. Lights up in Ionizer

Automatic Restart Control

  • Operation is restarted after power failure at previous setting mode.

Mode Operation. • SUPER ALLERU-BUSTER (Blue) ... Lights up in

Microcomputer-controlled Room Temperature Control

operation.

Page 5 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 5 · click to enlarge
Page 5

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Breakdown Self Diagnosis Function

Low Pressure Control (Gas Leakeage Detection)

Indoor Power Relay Control

Deodorizing Control

Anti-Dew Formation Control

Anti Freezing Control

Anti-Cold Draft Control

Hot Start

Intake Air Temperature Control

High Pressure Control

Deice Operation

Page 6 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 6 · click to enlarge
Page 6

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2.3. Outdoor Unit

Time Delay Safety Control

30 seconds Forced Operation

Overload Protection Control

Total Running Current Control

Compressor Overheating Prevention Control

IPM (Power Transistor) Overheating Protection Control

Low Operation Frequency Protection Control

Mininum Operation Frequency Protection Control

Outdoor Air Temperature Control

Standby Control

Deice Operation

Page 7 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — INTAKE
Page 7 · click to enlarge
Page 7

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

3 Product Specifications

3.1. CS-E9DKEW CU-E9DKE

Cooling Capacity kW kcal/h BTU/h

2.6 (0.80 - 3.00) 2,240 (690 - 2,580) 8,870 (2,050 - 10,200)

Heating Capacity kW kcal/h BTU/h

3.6 (0.80 - 5.00) 3,100 (690 - 4,300) 12,300 (2,050 - 17,100)

Moisture Removal l/h Pint/h

1.6 (3.4)

Power Source (Phase, Voltage, Cycle) ø V Hz

SIDE VIEW

TOP VIEW

Panasonic Air Conditioner (CS-E9DKEW) — SIDE VIEW diagram (page 7)
Fig. 6
Panasonic Air Conditioner (CS-E9DKEW) — SIDE VIEW diagram (page 7)
Fig. 7

INTAKE

Air Volume Lo m3/min (cfm) Cooling; 6.2 (220) — Heating; 6.6 (230) Me m3/min (cfm) Cooling; 7.9 (280) — Heating; 8.6 (300) Hi m3/min (cfm) Cooling; 9.6 (340) Cooling; 29.8 (1,050) Heating; 10.5 (370) SHi m3/min (cfm) Cooling; 9.9 (350) — Heating; 10.8 (380)

dB (A) Cooling; High 39, Low 26 Cooling; 46 Heating; High 40, Low 27 Heating; 47 Noise Level

Power level dB Cooling; High 50 Cooling; High 59 Heating; High 51 Heating; High 60

Electrical Data Input W Cooling; 600 (175 - 780) Heating; 845 (165 - 1,360)

Running Current A Cooling; 2.9 Heating; 4.0

EER W/W (kcal/hw), BTU/hw Cooling; 4.33 (3.73), 14.8 COP W/W (kcal/hw), BTU/hw Heating; 4.26 (3.67), 14.6 Starting Current A 4.0 Piping Connection Port (Flare piping)

G ; Half Union 3/8”

G ; 3-way valve 3/8”

L ; 2-way valve 1/4” Pipe Size (Flare piping)

L ; Half Union 1/4”

G (gas side) ; 3/8” L (liquid side) ; 1/4” Drain Hose

G (gas side) ; 3/8” L (liquid side) ; 1/4”

Inner diameter mm 12 — Length m 0.65 —

Show 5 more labels / short text on this page
Unit CS-E9DKEW CU-E9DKE · Single · Airflow Method OUTLET · inch inch · inch inch
Page 8 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 8 · click to enlarge
Page 8

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

UnitCS-E9DKEWCU-E9DKE Power Cord Length Number of core-wire— —— — DimensionsHeightinch (mm)11 - 1/32 (280)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)7 - 7/32 (183)11 - 3/8 (289) Net Weightlb (kg)20 (9.0)82 (37) CompressorType—Hermetic Rotary MotorType—Brushless (6-pole) RatedOutputW—700 Air CirculationTypeCross-flow FanPropeller Fan MaterialASG20k1P.P MotorTypeTransistor (8-poles)Induction (6-poles) InputW—61.3 Rate OutputW3028 Fan SpeedLo (Cool/Heat)rpm820/880— Me (Cool/Heat)rpm1,050/1,140— Hi (Cool/Heat)rpm1,280/1,400770 SHi (Cool/Heat)rpm1,320/1,440— Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium Fin TypeSlit FinCorrugated Fin Row / Stage(Plate fin configuration, forced draft) 2 / 152 / 24 FPI2117 Size (W × H × L)mm610 × 315 × 25.4718.4 689.8× 504 × 36.4 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—RB68A (320) Refrigerant (R410A)g (oz)—965 (34.1) ThermostatElectronic Control— Protection DeviceElectronic ControlElectronic Control Lengthmm—C1, C2 ; 950, C3 ; 411 Capillary TubeFlow Ratel/min—C1, C2 ; 4.1, C3 ; 18.8 Inner Diametermm—C1, C2 ; 1.1, C3 ; 1.7 Air FilterMaterial StyleP.P. Honeycomb— Fan Motor CapacitorµF, VAC—2.0 µF, 440 VAC Compressor CapacitorµF, VAC—65 µF, 350 VAC
  • Specifications are subject to change without notice for further improvement.
Page 9 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — SIDE VIEW
Page 9 · click to enlarge
Page 9

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

3.2. CS-E12DKEW CU-E12DKE

Cooling Capacity kW kcal/h BTU/h

3.50 (0.80 - 4.00) 3,010 (690 - 3,440) 11,950 (2,730 - 13,600)

Heating Capacity kW kcal/h BTU/h

4.80 (0.80 - 6.50) 4,130 (690 - 5,590) 16,400 (2,730 - 22,200)

Moisture Removal l/h Pint/h

2.0 (4.2)

Power Source (Phase, Voltage, Cycle) ø V Hz

SIDE VIEW

TOP VIEW

INTAKE

Air Volume Lo m3/min (cfm) Cooling; 6.9 (240) — Heating; 8.1 (290) Me m3/min (cfm) Cooling; 8.8 (310) — Heating; 9.7 (340) Hi m3/min (cfm) Cooling; 10.7 (380) Cooling; 31.0 (1,090) Heating; 11.2 (400) SHi m3/min (cfm) Cooling; 11.0 (390) — Heating; 11.6 (410)

dB (A) Cooling; High 42, Low 29 Cooling; 48 Heating; High 42, Low 33 Heating; 50 Noise Level

Power level dB Cooling; High 53 Cooling; High 61 Heating; High 53 Heating; High 63

Electrical Data Input W Cooling; 965 (185 - 1,200) Heating; 1,260 (175 - 1,890)

Running Current A Cooling; 4.5 Heating; 5.8

EER W/W (kcal/hw), BTU/hw Cooling; 3.63 (3.12), 12.4 COP W/W (kcal/hw), BTU/hw Heating; 3.81 (3.28), 13.0 Starting Current A 5.8 Piping Connection Port (Flare piping)

G ; Half Union 1/2”

G ; 3-way valve 1/2”

L ; 2-way valve 1/4” Pipe Size (Flare piping)

L ; Half Union 1/4”

G (gas side) ; 1/2” L (liquid side) ; 1/4” Drain Hose

G (gas side) ; 1/2” L (liquid side) ; 1/4”

Inner diameter mm 12 — Length m 0.65 — Power Cord Length Number of core-wire

Show 5 more labels / short text on this page
Unit CS-E12DKEW CU-E12DKE · Single · Airflow Method OUTLET · inch inch · inch inch
Page 10 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 10 · click to enlarge
Page 10

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

UnitCS-E12DKEWCU-E12DKE DimensionsHeightinch (mm)11 - 1/32 (280)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)7 - 7/32 (183)11 - 3/8 (289) Net Weightlb (kg)20 (9.0)82 (37) CompressorType—Hermetic Rotary MotorType—Brushless (6-pole) RatedOutputW—700 Air CirculationTypeCross-flow FanPropeller Fan MaterialASG20k1P.P MotorTypeTransistor (8-poles)Induction (6-poles) InputW—65.9 Rate OutputW3029 Fan SpeedLo (Cool/Heat)rpm910/1,080— Me (Cool/Heat)rpm1,165/1,290— Hi (Cool/Heat)rpm1,420/1,500830 SHi (Cool/Heat)rpm1,460/1,540— Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium Fin TypeSlit FinCorrugated Fin Row / Stage(Plate fin configuration, forced draft) 2 / 152 / 24 FPI2117 Size (W × H × L)mm610 × 315 × 25.4718.4 689.8× 504 × 36.4 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—RB68A (320) Refrigerant (R410A)g (oz)—980 (34.6) ThermostatElectronic Control— Protection DeviceElectronic ControlElectronic Control Lengthmm—C1, C2 ; 1,120, C3 ; 370 Capillary TubeFlow Ratel/min—C1, C2 ; 4.9, C3 ; 19.6 Inner Diametermm—C1, C2 ; 1.2, C3 ; 1.7 Air FilterMaterial StyleP.P. Honeycomb— Fan Motor CapacitorµF, VAC—2.0 µF, 440 VAC Compressor CapacitorµF, VAC—65 µF, 350 VAC
  • Specifications are subject to change without notice for further improvement.
Page 11 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 11 · click to enlarge
Page 11

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

4 Dimensions

4.1. Indoor Unit & Remote Control

4.1.1. CS-E9DKEW CS-E12DKEW

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 11)
Fig. 8
Page 12 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 12 · click to enlarge
Page 12

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

4.2. Outdoor Unit

4.2.1. CU-E9DKE CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 12)
Fig. 9
Page 13 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 13 · click to enlarge
Page 13

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

5 Refrigeration Cycle Diagram

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 13)
Fig. 10
Page 14 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 14 · click to enlarge
Page 14

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

6 Block Diagram

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 14)
Fig. 11
Page 15 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 15 · click to enlarge
Page 15

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

7 Wiring Diagram

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 15)
Fig. 12
Page 16 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 20 +3.5 X
Page 16 · click to enlarge
Page 16

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8 Operation Details

8.1. Basic Function

Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air temperature.

8.1.1. Internal Setting Temperature

Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes. These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.1. Internal Setting Temperature diagram (page 16)
Fig. 13 · 8.1.1. Internal Setting Temperature
Table (a)Auto Operation Mode Setting
Mode ShiftTemperature Shift (°C) Cooling/Soft Dry → Heating -2.0 Heating → Cooling/Soft Dry +2.0
Table (b)Outdoor Air Temperature Shifting
ModeOutdoor Temperature, X (°C): Temperature Shift (°C) Cooling/Soft Dry 30

X +0.5 X

30 +1.0 Heating 9

X -1.0 5

9 -0.5 1

5 0.0 X

1 +1.0

Table (c)Powerful Mode Shifting
ModePeriod, X (min): Temperature Shift (°C) Cooling X

20 -2.0 X

20 0.0 Soft Dry X

20 -1.0 X

20 0.0 Heating X

20 +3.5 X

20 +3.5

Page 17 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 17 · click to enlarge
Page 17

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Table (d)Indoor Air Temperature Shifting
1. Target room temperature shift value (dGetaDst)
  • To offset the absolute gap between detection temperature with actual room temperature.
  • The heat exchanger unit’s temperature is different based on operation mode, it become the action operation mode

value.

Actual operation mode Target room temperature offset value (dGetaDst) Cooling (1) Heating (2) Dry (0)

2. Room temperature shift value (dGeta)
  • When compressor ON/OFF, correction of detected room temperature by shift value during defrost etc.

i) Initial value when operation starts, or changing the actual operation mode.

Set the offset value at each operation mode. However, in order to improve the heating start up efficiency, the offset value will be changed based on the gap between setting temperature and room temperature.

Actual operation mode Gap between setting temperature and room

Room temperature offset value

(dGeta) Cool — (0) Heat (Operation start set temp. - room temp)

4°C (4) Dry — (0)

ii) Updating during operation

During operation, it will compare with the target room temperature offset value at specific period, then the room temperature will be updated.

Actual operation mode Room temperature zone Updating period (sec.) Cool — (180) Heat A, B, C, D zone (15) Dry — (180)

Update the room temperature offset value (dGeta)

Temperature condition Room temp. offset value after modified (dGeta) Target room temp. offset value > Room temp. offset value

dGeta + (0.5)

Target room temp. offset value < Room temp. offset value

dGeta - (0.5)

Target room temp. offset value = Room temp. offset value

However, if the following condition is occurred, temperature cannot detect correctly and therefore no updating will be done.

  • Heating zone E and above (Temperature gap is big and great capacity increased)
  • During deice
  • After deice complete *within 600 sec.
  • Comp stop

Comp starting *within 600 sec.

Show 5 more labels / short text on this page
temperature · (dGetaDst > dGeta) · (dGetaDst < dGeta) · Do not change · (dGetaDst = dGeta)
Page 18 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.2.1.3. Change frequency determination
Page 18 · click to enlarge
Page 18

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.2. Compressor Operation Frequency

8.1.2.1. The frequency determination method (Cooling operation control)

8.1.2.1.1. Basic specification

The domain directions data (intake-setting) transmitted from the interior of a room determines a changed part of frequency.

Then, a directed changed part changes frequency to the present frequency.

8.1.2.1.2. Initial frequency determination

After a starting control end, initial frequency (absolute value) is determined.

However, a FcMAX domain judges instantly.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.2.1.2. Initial frequency determination diagram (page 18)
Fig. 14 · 8.1.2.1.2. Initial frequency determination

8.1.2.1.3. Change frequency determination

When (Suction-setup) is +0.5deg, directions of Fcmax came by the mentioned initial frequency.

Fcmax continued until it reaches. (If other directions came by protection control, priority is given)

When room temperature is reached, it shifts to relative control after moving to change frequency.

The following operation determines change frequency.

The Hzkirikae = present condition frequency * Inclines and it is calculation.

Inclination = lapsed time to remote control attaintment (Minute)

Inclination 0 - 60 60 - 90 90 Inclination coefficient 80% 90% 100%

1. The present frequency is real operation frequency.
2. When change directions come out with remote control after starting, continue calculation as it is.

The time to room temperature attainment is calculated.

3. When remote control directions were changed before room temperature attainment and below room temperature attainment temperature becomes

With initial frequency, it is considered as change frequency.

Page 19 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.2.2. The frequency determination method (Heating operation control)
Page 19 · click to enlarge
Page 19

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.2.1.4. The frequency changed method

1. After shifting to relative control, (intake-setting) is every 60 seconds, A tap is adjusted according to the domain and frequency

changes relatively to present condition.

2. Intake-setting to other domains by load sudden change (remote control setting, open air introduction, etc.). When it moves, it

has the following renewal of data, an addition and subtraction tap is switched.

3. When the load change was further carried out and suction-setup separates the domain of relative control, it goes to the clause

of initial frequency and operation frequency is determined.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 19)
Fig. 15

8.1.2.2. The frequency determination method (Heating operation control)

8.1.2.2.1. Basic specification

Intake temperature domain is sent to outdoor. Renewal of data every 60 seconds in outdoor.

Domain directions data (intake-setting) transmitted from indoor determine a changed part of frequency.

Then, a directed changed part changes frequency to the present frequency.

Change of frequency may be 1 tap = 1Hz.

Page 20 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.2.2.3. Change frequency determination
Page 20 · click to enlarge
Page 20

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.2.2.2. Initial frequency determination

After a starting control end, initial frequency (absolute value) is determined and is immediately shift.

However, the domain of Fhmax is judged instantly.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 20)
Fig. 16

8.1.2.2.3. Change frequency determination

When directions of Fhmax determined from mentioned initial frequency, (intake-setting) relativity control. Fhmax continued until (If other directions came by protection control, priority is given there) room temperature is reached, it shifts to relative control after moving to change frequency.

The following operation determines change frequency.

The Hzkirikae = present condition frequency *Inclines (calculation)

Inclination = Lapsed time to remote control attainment (min)

Inclination 0 - 30 30 - 60 60 Inclination coefficient 70% 90% 100%

1. The present frequency is real operation frequency.
2. When directions change come out by remote control after starting, calculation continued.

The time to room temperature attainment is calculated.

3. When remote control directions were changed before room temperature achieved and below room temperature attainment temperature becomes

With initial frequency, it is considered as change frequency.

Page 21 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.2.3.2. Initial frequency determination
Page 21 · click to enlarge
Page 21

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.2.2.4. The frequency changed method

1. When intake-setting remains for 30 seconds in a domain after shifting to relative control, a tap is adjusted according to the

domain and frequency changes relatively to the present condition.

2. A suction-setup to other domains by load sudden change (remote control setting change, open air introduction, etc.).

When it moves, addition or subtraction tap is changed at the time of the following renewal of data.

3. When the load change was furthermore carried out and a suction-setup separates from the domain of relative control, it goes

to the clause of initial frequency and operation frequency is determined.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 21)
Fig. 17

8.1.2.3. The frequency determination method (Soft Dry operation control)

8.1.2.3.1. Basic specification

The domain directions data (intake-setting) transmitted from indoor determines a changed part of frequency.

Then, a directed changed part changes frequency to the present frequency.

Change of frequency may be 1 tap = 1Hz.

It applies to cooling correspondingly.

8.1.2.3.2. Initial frequency determination

It shifts to initial frequency after a starting frequency end.

22°C ID intake < 22°C Frequency ESCHZ02 ESCHZ01 38 (E12), 31 (E9) 34 (E12), 28 (E9)

ID intake

Page 22 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.3. Cooling Operation
Page 22 · click to enlarge
Page 22

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.2.3.3. The frequency change method

1. When (suction-setup) remains in a domain for 30 seconds, after shifting to relative control, a tap is adjusted according to the

domain and frequency changes relatively to the present condition.

2. A suction-setup is to other domains by load sudden change (remote control setting, open air introduction, etc.). When it moves,

an addition-and-subtraction tap is changed from the time of the following renewal of data.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 22)
Fig. 18

8.1.3. Cooling Operation

8.1.3.1. Thermostat control

  • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF

point.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.3. Cooling Operation diagram (page 22)
Fig. 19 · 8.1.3. Cooling Operation
Page 23 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.6. Automatic Operation
Page 23 · click to enlarge
Page 23

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.4. Soft Dry Operation

8.1.4.1. Thermostat control

  • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.0°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF

point.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 23)
Fig. 20

8.1.5. Heating Operation

8.1.5.1. Thermostat control

  • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF

point.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.5. Heating Operation diagram (page 23)
Fig. 21 · 8.1.5. Heating Operation

8.1.6. Automatic Operation

This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air temperature and outdoor air temperature.

During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to detect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.6. Automatic Operation diagram (page 23)
Fig. 22 · 8.1.6. Automatic Operation
Page 24 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.7. Indoor Fan Motor Operation
Page 24 · click to enlarge
Page 24

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2 and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on the above operation mode chart, every 30 minutes.

Remote Control Setting Temperature (°C) T1 T2 T3 16 ~ 18 +10 -3 -5 19 ~ 22 +8 -3 -7 23 ~ 26 +7 -3 -7 27 ~ 30 +6 -3 -8

There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice verse.

Operation Mode change from Temperature shifts (°C) Cooling/Soft Dry →Heating -2 Heating →Cooling/Soft Dry +2

Example of operation mode chart adjustment:

From the above table, if remote control setting temperature = 25,

T1 = 25 + 7 = 32; T2 = 25 - 3 = 22; T3 = 25 - 7 = 18

The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on indoor intake air temperature and outdoor air temperature at the time when the judgment is made.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 24)
Fig. 23

8.1.7. Indoor Fan Motor Operation

A. Basic Rotation Speed (rpm)

  • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)

Remote Control — — O — — — Tab (rpm) PSHI SHI Hi Me+ Me Me- Lo Lo- SLo SSLo E9DK 1320 1320 1280 1165 1050 935 820 760 720 710 E12DK 1460 1460 1420 1293 1165 1038 910 840 720 710

Remote Control — — O — — — Tab (rpm) PSHi SSHi SHi Me+ Me Me- Lo Lo- SLo SSLo E9DK 1440 1440 1400 1270 1140 1010 880 820 720 710 E12DK 1540 1540 1500 1395 1290 1185 1080 1010 720 710

[Cooling, Dry, Fan] · [Heating]

Page 25 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 25 · click to enlarge
Page 25

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

B. Indoor Fan Control

i. Indoor fan control operation outline

1. Cooling / Dry
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 25)
Fig. 24
Page 26 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 26 · click to enlarge
Page 26

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2. Heating
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 26)
Fig. 25

ii. Auto Fan Speed

1. Cooling
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 26)
Fig. 26
Page 27 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 27 · click to enlarge
Page 27

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2. Heating
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 27)
Fig. 27

a. UP:

  • If move from Lo, the fan speed will be shifted to Maximum 1520 rpm.
  • If move from Maximum, the fan speed no change.
  • In up zone, 10 rpm is added for every 10s until Maximum 1520 rpm.

b. DOWN:

  • The fan speed will be decreased one step every 10 sec. until Minimum 1270 rpm.

c. Current Output Fixed:

  • Maintain at present fan speed.

d. Instantaneous Maximum:

  • Fan speed will be increased to maximum auto fan speed.

e. Temperature in ( ) is for Powerful Mode operation.

C. Fan Motor Control

1. Motor specification

High voltage PWM Motor

2. Feedback Control

a. Number-of-rotations feedback

Immediately after the fan started, rpm is checked and duty is added, and feedback control is performed. For high voltage PWM motor, it is done once every 0.5 second.

b. Offset duty T max/min limit

High voltage PWM motor has maximum offset duty.

(Refer Indoor fan motor control basic rotation speed)

3. Abnormal Detection Control

Conditions:

a. Out of rhythm signal input

b. If feedback number of rotations exceeded #2550 r/min or when less than #50 r/min.

ControlFans stop
ReturnRestart after 5 seconds

* It will not detect the out of rhythm condition within 5s for phase control motor (PWM motor is when duty=0) after start.

A fan stops when condition (1) and (2) happen within 25.0 seconds after fan starting, and if this happens for continuously 7 times, it will not retry.

→FM lock processing

4. Restart Prohibition Control

Restart is prohibited within 5s for phase control motor (PWM motor is when duty=0) after fan stop (except re-ON the power supply).

Page 28 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.9. Airflow Direction
Page 28 · click to enlarge
Page 28

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

D. Deodorizing Control

i. Control condition

Control at cooling/dry operation and auto fan speed.

No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.

ii. Operation

The odor status is arranged as below and it is shifted as follow.

* When COMP is ON 1 →2 →3 (Shift to 4 when COMP is OFF) * When COMP is OFF 4 →5 →6 →7 →6 ←→7 (Shift to 1 when COMP is ON) * Start from 4 if the Thermostat is OFF during the start operation.

Odor Status 1 2 3 4 5 6 7 6.7.6... 1 Status Shift according to COMP

ON OFF ON

zone 40 50 — 30 90 20 90 20.90.20... to time (s) Dry zone ON

SSLo OFF SSLo OFF SSLo.OFF... Dry zone SLo

Panasonic Air Conditioner (CS-E9DKEW) — ON OFF ON diagram (page 28)
Fig. 28

8.1.8. Outdoor Fan Motor Operation

Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after compressor stops operation.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.8. Outdoor Fan Motor Operation diagram (page 28)
Fig. 29 · 8.1.8. Outdoor Fan Motor Operation

8.1.9. Airflow Direction

1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature

and intake air temperature) and manual (angles of direction can be adjusted using remote control).

Show 7 more labels / short text on this page
Status Shift · Cooling · according · Cooling · Auto Fan Speed · Fan Speed · zone OFF SSLo
Page 29 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.9.2. Horizontal Airflow
Page 29 · click to enlarge
Page 29

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.9.1. Vertical Airflow

Operation Mode Airflow Direction Vane Angle (°) 1 2 3 4 5 Heating Auto with Heat Exchanger A Upward fix 3 Temperature B Downward fix 64 C Upward fix 3 D Downward fix 3 Manual 3 17 33 49 63 Cooling, Soft Dry and Ion Auto 8 ~ 36 Manual 8 15 22 30 36 Mode Judgment in Auto Auto 8 Manual 8 15 22 30 36

1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated

above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane will shift to close position.

2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions

of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 29)
Fig. 30

8.1.9.2. Horizontal Airflow

1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated

below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below.

Operation Mode Vane Angle (°) Heating, with heat exchanger temperature A 65 ~ 115 B 90 Cooling, Soft Dry and Ion 65 ~ 115

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.9.2. Horizontal Airflow diagram (page 29)
Fig. 31 · 8.1.9.2. Horizontal Airflow
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positions

of the vane are as Figure 2 above.

Pattern 1 2 3 4 5 Airflow Direction Patterns at Remote Control

Vane Angle (°) 90 65 78 102 115

Page 30 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.10.1. Quiet operation (Heating)
Page 30 · click to enlarge
Page 30

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.1.10. Quiet operation (Cooling Mode/Cooling area of Dry Mode)

A. Purpose

To provide quiet cooling operation compare to normal operation.

B. Control condition

a. Quiet operation start condition

  • When “quiet” button at remote control is pressed.

Quiet LED illuminates.

b. Quiet operation stop condition

1. When one of the following conditions is satisfied, quiet operation stops:

a. Powerful button is pressed.

b. Stop by OFF/ON switch.

c. Timer “off” activates.

d. Quiet button is pressed again.

2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.

C. Control contents

1. Fan speed is changed from normal setting to quiet setting of respective fan speed.

This is to reduce sound of Hi, Me, Lo for 3dB.

2. Fan speed for quiet operation is -1 step from setting fan speed.

8.1.10.1. Quiet operation (Heating)

A. Purpose

To provide quiet heating operation compare to normal operation.

B. Control condition

a. Quiet operation start condition

  • When “quiet” button at remote control is pressed.

Quiet LED illuminates.

b. Quiet operation stop condition

1. When one of the following conditions is satisfied, quiet operation stops:

a. Powerful button is pressed.

b. Stop by OFF/ON switch.

c. Timer “off” activates.

d. Quiet button is pressed again.

2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except fan only mode.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
Page 31 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.12. Delay ON Timer Control
Page 31 · click to enlarge
Page 31

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

C. Control contents

a. Fan Speed manual

1. Fan speed is changed from normal setting to quiet setting of respective fan speed.

This is to reduce sound of Hi, Me, Lo for 3dB.

2. Fan speed for quiet operation is -1 step from setting fan speed.
3. Fan Speed Auto

Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.

8.1.11. Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature quickly.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.11. Powerful Mode Operation diagram (page 31)
Fig. 32 · 8.1.11. Powerful Mode Operation

(b) Soft Dry Operation

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.11. Powerful Mode Operation diagram (page 31)
Fig. 33 · 8.1.11. Powerful Mode Operation
Panasonic Air Conditioner (CS-E9DKEW) — 8.1.11. Powerful Mode Operation diagram (page 31)
Fig. 34 · 8.1.11. Powerful Mode Operation

8.1.12. Delay ON Timer Control

Delay ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time.

60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.

From the above judgment, the decided operation will start operate earlier than the set time as shown below.

(a) Cooling Operation · (c) Heating Operation

Page 32 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.16. Auto Operation Switch
Page 32 · click to enlarge
Page 32

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 32)
Fig. 35

8.1.13. Delay OFF Timer Control

Delay OFF timer can be set using remote control, the unit with timer set will stop operate at set time.

8.1.14. Auto Restart Control

1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four

minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes.

2. This type of control is not applicable during ON/OFF Timer setting.

8.1.15. Indication Panel

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.15. Indication Panel diagram (page 32)
Fig. 36 · 8.1.15. Indication Panel

LED POWER TIMER QUIET POWERFUL ION ALLERGEN

BUSTER Color Green Orange Orange Orange Green Blue Light ON Operation ON Timer Setting ON Quiet Mode ON Powerful Mode ON Ion Mode ON Operation ON Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF Ion Mode OFF Operation OFF

  • If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode

judgment, or delay ON timer sampling.

  • If Timer LED is blinking, there is an abnormality operation occurs.
  • If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.

8.1.16. Auto Operation Switch

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.16. Auto Operation Switch diagram (page 32)
Fig. 37 · 8.1.16. Auto Operation Switch
Page 33 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.17. Ionizer Operation
Page 33 · click to enlarge
Page 33

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3. When the switch is pressed between 8 to 11 seconds, the unit will enter forced Heating Mode standby. Press timer decrement

button for 5s for the unit to operate in Heating Mode.

4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control (timer decrement button

for 5s), the unit can be changed to different controlling setting (4 type of transmission codes).

5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote control signal

receiving sound can be cancelled or turned on.

8.1.17. Ionizer Operation

To provide fresh air effect to users by discharging minus ion to air.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.17. Ionizer Operation diagram (page 33)
Fig. 38 · 8.1.17. Ionizer Operation

a. Ionizer Only Operation.

1. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at remote control is pressed.

Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1 →2)

However, fan speed can be adjusted later by customer during this operation.

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.17. Ionizer Operation diagram (page 33)
Fig. 39 · 8.1.17. Ionizer Operation

Airflow direction (Horizontal Vane) control:

Follow vane direction control at cooling mode.

Horizontal vane can be changed by customer during ion only operation.

b. Operation Mode + Ionizer Operation.

1. Ionising Operation Start Condition

When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Auto mode) and ION operation button at remote control is pressed. Ionizer on & ION LED illuminates. (3 →4)

Power LED also illuminates.

Purpose · Control Condition

Page 34 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.1.17.2. Ionizer Operation case study
Page 34 · click to enlarge
Page 34

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2. Ionising Operation Stop Condition

When one of the following condition is satisfied, ION operation stops.

a. Stopped by ON/OFF switch.

b. Timer OFF activates.

c. ION feedback signal shows error.

3. Ionizer operation status is not memorised by micon. After OFF, when operation is “ON” again, air conditioner operates

without ionizer operation.

c. Timer during ionizer operation

Refer to case study in next page for detail.

8.1.17.1. Ionizer Problem Detection Control

i. Purpose

To inform user of ionizer problems and detection.

ii. Two types of problem detection control:

Control Detection Method Protection Recovery

ERROR PROTECTION

(i) Actual ionON (i) Actual ion ON for 10s & OFF for

(i) Actual ion is permanently OFF & ion

(i) Press ON/OFF button

30 min. continuously for 24 times (approx. 11 hr. 30 min.)

LED is blinking.

(ii) ion feedback signal:

0V (ii) Within 24 counts, if anytime

(ii) Press remote control ion button for

CONDITION becomes false then count is cleared.

a) ON: Ion LED blink & buzzer = beep b) OFF: Ion LED OFF & buzzer = beep

Off by force operation

BREAKDOWN PROTECTION

Case 1: During Air-Con. ON. Air-Cond OFF with abnormal no. H26 is activated with timer LED is blinking permanently.

Actual ionOFF

(i) Actual ion OFF

CONDITION becomes false.

ion feedback signal5V

Case 2: During Air-Con. OFF. Abnormal no. H26 is activated with timer LED is blinking permanently for both cases 1 & 2.

(ii) Once recovered, ion &

Timer LED stops blinking permanently. (ii) Press remote control ion button for

a) ONIon LED blink b) OFF: Ion LED OFF

(iii) Main power reset.

(iii) Press any remote control button to

a) ONBuzzer = beep beep beep beep b) OFF: Buzzer = beep beep beep beep

8.1.17.2. Ionizer Operation case study

Panasonic Air Conditioner (CS-E9DKEW) — 8.1.17.2. Ionizer Operation case study diagram (page 34)
Fig. 40 · 8.1.17.2. Ionizer Operation case study
Show 10 more labels / short text on this page
to OFF · (ii) · Reset power · (iii) · (i) · 2s (i) · (i) When anytime · (ii) · (i) · Case 1
Page 35 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.2.1.3. Total Running Current Control
Page 35 · click to enlarge
Page 35

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2. Protection Control Features

8.2.1. Protection Control For All Operations

8.2.1.1. Time Delay Safety Control

1. The compressor will not start for three minutes after stop of operation.
2. This control is not applicable if the power supply is cut off for 20 seconds and on again or after 4-way valve deices condition.

8.2.1.2. 30 Seconds Forced Operation

1. Once the compressor starts operation, it will not stop its operation for 30 seconds.
2. However, it can be stopped using remote control or Auto Switch at indoor unit.

8.2.1.3. Total Running Current Control

1. When the outdoor unit total running current (AC) exceeds X value, the frequency instructed for compressor operation will be

decreased.

2. If the running current does not exceed X value for five seconds, the frequency instructed will be increased.
3. However, if total outdoor unit running current exceeds Y value, compressor will be stopped immediately for 3 minutes.

Model E9DK E12DK Operation Mode X (A) Y (A) X (A) Y (A) Cooling/Soft Dry (A) 4.0 16.8 5.4 16.8 Cooling/Soft Dry (B) 3.6 16.8 5.0 16.8 Heating 5.5 16.8 8.4 16.8

4. The first 30 minutes of cooling operation, (A) will be applied.
Panasonic Air Conditioner (CS-E9DKEW) — 8.2.1.3. Total Running Current Control diagram (page 35)
Fig. 41 · 8.2.1.3. Total Running Current Control
Page 36 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.2.1.6. Low Pressure Prevention Control (Gas Leakage Detection)
Page 36 · click to enlarge
Page 36

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.1.4. IPM (Power transistor) Prevention Control

A. Overheating Prevention Control

1. When the IPM temperature rises to 100°C, compressor operation will stop immediately.
2. Compressor operation restarts after three minutes the temperature decreases to 95°C.

B. DC Peak Current Control

1. When electric current to IPM exceeds set value of 18.5 A, the compressor will stop operate. Then, operation will restart after

three minutes.

2. If the set value is exceeded again more than 30 seconds after the compressor starts, the operation will restart after two

minute.

3. If the set value is exceeded again within 30 seconds after the compressor starts, the operation will restart after one minute.

If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off.

8.2.1.5. Compressor Overheating Prevention Control

Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The changes of frequency are as below figure.

Panasonic Air Conditioner (CS-E9DKEW) — 8.2.1.5. Compressor Overheating Prevention Control diagram (page 36)
Fig. 42 · 8.2.1.5. Compressor Overheating Prevention Control

8.2.1.6. Low Pressure Prevention Control (Gas Leakage Detection)

a. Control start conditions

Control will perform when (1) - (3) condition continues operation for 5 minute and (4) is fulfill.

1. During cooling and dry operation: Frequency more than normal Fcmax.
During heating operationFrequency more than normal Fh
2. Outdoor total current I cooling: Ib
HeatingIb

Ic = Ia = 1.65 A

Ib = 0.65 A

3. It is not during deice operation.
4. During cooling and dry operation: indoor suction-indoor piping temperature is below 4°C.

During of heating operation: Indoor piping temperature-indoor suction is under 5°C.

Control contents:

  • compressor stops (restart after 3 minutes)
  • if happen 2 times within (20 minutes), perform the following operation
1. Unit stop operation
2. Timer LED blink and “F91” indicated

Ia

Page 37 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 38 T
Page 37 · click to enlarge
Page 37

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.1.7. Compressor Tank Temperature Rise Protection Control

a. Control start conditions

Control will perform when (1) - (3) condition continues operation for 5 minute and (4) is fulfill.

1. During cooling and dry operation: Frequency more than normal Fc.
Air-temperatureIndoor and outdoor 30±5 degrees C

Remote control Hi; 16 degrees C

During Heating operationFrequency more than Fh
Air temperatureIndoor and outdoor 20±2 degrees C

Remote control Hi; 30 degrees C

2. Outdoor total current I Air conditioning: 0.65
Heating0.65<=I<1.65

It is not during deice operation

3. During cooling and dry operation: indoor suction-indoor piping temperature is below 4°C.

During heating operation: Indoor piping temperature-indoor suction is under 5°C.

Control contents:

  • compressor stops (restart after 3 minutes)
  • if happen 2 times within (20 minutes), perform the following operation
1. Unit stop operation
2. Timer LED blink and “F91” indicated

8.2.1.8. Low Frequency Protection Control 1

When the compressor operate at frequency lower than 22 Hz continued for 20 minutes, the operation frequency will be increased to 22 Hz for two minutes.

8.2.1.9. Low Frequency Protection Control 2

When all the below conditions occur, minimum value (Freq. MIN) for the frequency instructed to compressor will change to 30 Hz for cooling mode operation and 20 Hz for heating mode operation.

Temperature, T, forCooling/Soft Dry Heating Indoor intake air (°C) T

30 — Outdoor air (°C) T

24 Indoor heat exchanger (°C) T

38 T

30 T

8.2.1.10. Minimum Frequency Protection Control

  • During cooling operation (except Anti Freezing control, soft dry) carry out the following operation.
1. During Remote Control setting is 28°C & below.

Indoor Fan Speed min Hz More than Hi 29 More than Me- 27 Less than Me- 27 Automatic 27

However, when less than thermo OFF for 120 sec. continuously, the above control will be cancel.

15 or T · 16 or T · 4 or T

Page 38 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.2.2. Protection Control For Cooling & Soft Dry Operation
Page 38 · click to enlarge
Page 38

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

  • During heating operation, operate the followings control.
1. During Remote Control setting is 18°C & above

Indoor Fan Speed Min Hz More than Hi 27 More than Lo 27 Under Lo 27

However, when less than thermo OFF for 100 sec. continuously, the above control will be cancel.

8.2.1.11. DC Current Protection Control

In order to control DC current rise in a compressor low frequency region, load is detected with from indoor/outdoor heat exchanger temperature, Hz control is performed.

1. During cooling and dry except test mode
Panasonic Air Conditioner (CS-E9DKEW) — 8.2.1.11. DC Current Protection Control diagram (page 38)
Fig. 43 · 8.2.1.11. DC Current Protection Control
2. During heating compressor operation, except test mode.

(However, official approval mode removes)

Panasonic Air Conditioner (CS-E9DKEW) — 8.2.1.11. DC Current Protection Control diagram (page 38)
Fig. 44 · 8.2.1.11. DC Current Protection Control

8.2.2. Protection Control For Cooling & Soft Dry Operation

8.2.2.1. Outdoor Air Temperature Control

The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below.

This control will begin one minute after the compressor starts.

Panasonic Air Conditioner (CS-E9DKEW) — 8.2.2. Protection Control For Cooling & Soft Dry Operation diagram (page 38)
Fig. 45 · 8.2.2. Protection Control For Cooling & Soft Dry Ope…

Purpose · Control contents

Page 39 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 39 · click to enlarge
Page 39

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.2.2. Cooling Overload Control

i. Pipe temperature limitation/restriction

  • Detects the Outdoor pipe temperature and carry out below restriction/limitation (Limit the compressor Operation frequency)
  • The compressor stop if outdoor pipe temperature exceeds 61°C
  • If the compressor stops 4 times in 20 minutes, Timer LED blinking (F95: outdoor high pressure rise protection)
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 39)
Fig. 46

ii. Electrical part temperature rise protection control

1. Purpose

To prevent electronic components temperature rise during cooling overload.

2. Judgement Conditions
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 39)
Fig. 47
3. Control contents

- Change a current limit value in a protection location A. (Refer to the clause of total running current control value)

4. Condition resolutive

It is canceled when it stops satisfying all of the above-mentioned.

Outdoor temperature

Page 40 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.2.3. Protection Control For Heating Operation
Page 40 · click to enlarge
Page 40

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.2.3. Anti-Freezing Control

1. When indoor heat exchanger temperature is lower than 2°C continuously for six minutes, compressor will stop operating.
2. Compressor will resume its operation three minutes after the indoor heat exchanger is higher than 10°C.
3. At the same time, indoor fan speed increase +20 rpm compared to its normal operation.
4. If indoor heat exchanger temperature is higher than 10°C for five minutes, the fan speed will return to its normal operation.
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 40)
Fig. 48

8.2.2.4. Anti-Dew Formation Control

1. When indoor fan speed is set at Meor slower, the compressor operating frequency is regulated by operation time to prevent

fog discharged from indoor as shown in below table.

rpm Operation time, T (min) E9DK E12DK 0

30 26 Hz 39 Hz Below 710 30

T

90 26 Hz 37 Hz 90

T

420 26 Hz 37 Hz 0

T

30 40 Hz 59 Hz 710 ~ 790 30

T

90 33 Hz 48 Hz 90

T

420 32 Hz 47 Hz 0

T

30 50 Hz 70 Hz 791 ~ 970 30

T

90 40 Hz 59 Hz 90

T

420 40 Hz 59 Hz 0

T

30 52 Hz 72 Hz 970 above 30

T

90 40 Hz 59 Hz 90

T

T

420 40 Hz 59 Hz

2. After 420 minutes, the operation restarts again from the beginning.
3. The operation will restart the above control whenever remote controller setting temperature or fan speed setting is changed.

8.2.3. Protection Control For Heating Operation

8.2.3.1. Intake Air Temperature Control

Compressor will operate at Max freq 67 Hz if either one of the below conditions occur:

1. When the indoor intake air temperature is less than 20°C and remote control setting fan speed is lower Me-.
2. When the indoor intake air temperature is 30°C or above.
Page 41 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8.2.3.3. Overload Protection Control
Page 41 · click to enlarge
Page 41

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.3.2. Outdoor Air Temperature Control

The Max current value is regulated in accordance to the outdoor air temperature as shown in the below figures.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 41)
Fig. 49

8.2.3.3. Overload Protection Control

The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown in below figures.

Panasonic Air Conditioner (CS-E9DKEW) — 8.2.3.3. Overload Protection Control diagram (page 41)
Fig. 50 · 8.2.3.3. Overload Protection Control
Page 42 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 42 · click to enlarge
Page 42

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8.2.3.4. Deice Control

A. Deice operation (Normal Deice Operation)

1. Detection methods

Outdoor heat exchanger temperature sensor, timer.

2. Deice operation time chart
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 42)
Fig. 51
  • During deice operation, as relationship for outdoor piping temperature and time T5, the priority given to the condition

which is first fulfilled and shift to the next mode.

  • First deice after operation restricted to 60 min. & above.
  • No restart operation if compressor OFF for sequence No. 8, 9.
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 42)
Fig. 52

Outdoor heat exchanger temperature

a 15°C b 18°C c 25°C

(Instantaneous, restart)

Page 43 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 43 · click to enlarge
Page 43

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

3. Explanation of operation
1. At the deice starting signal, the compressor frequency is set to the value as previously mentioned.
2. At 120 sec. after deice starting signal generated, 4 way valve OFF and at the same time outdoor fan is OFF, indoor fan is OFF, compressor frequency is set to the previously mentioned value.
3. WIthin 30 sec. after the 4 way valve OFF, the compressor frequency is set to the previously mentioned value.
4. If the outdoor heat exchanger temperature is above a°C, the compressor frequency is set to the value as previously mentioned.
5. After the compressor frequency is changed according to the item 4), in case either outdoor heat exchanger temperature more than b°C or 10.5 minutes lapsed after 4 way valve OFF is fulfilled, 30 sec. calculation start.
6. After 5) operated, if the outdoor heat exchanger temperature is more than c°C or 30 sec. lapsed, deice operation completion signal transmit, the compressor frequency is set to the previously mentioned value. And timingly ON signal transmit on outdoor FM.
7. After 59 sec. lapsed after deice operation completion signal generated, 4 way valve/indoor fan is ON, compressor frequency become FREE, and recover to normal heating operation.
4. Deice operation judgement condition

When any of below a, b, c, d condition is satisfied, deice signal is produced.

a. Continuously, outdoor heat exchanger temperature < 3°C for 120 minutes and outdoor heat exchanger temperature

< -6°C for 3 minutes and outdoor air temperature > -1°C and Comp. is ON.

b. Continuously, outdoor heat exchanger temperature < 3°C for 80 minutes and outdoor heat exchanger temperature

< -7°C for 3 minutes and outdoor air temperature > -1°C and Comp. is ON.

c. Continuously, outdoor heat exchanger temperature < 3°C for 40 minutes and outdoor heat exchanger temperature

< -9°C for 3 minutes and outdoor air temperature

-3°C and Comp. is ON.

d. Continuously, outdoor heat exchanger temperature < 3°C for 40 minutes and outdoor heat exchanger temperature

< -11°C for 3 minutes and outdoor air temperature < -3°C and Comp. is ON.

However, the first deice will start only after minimum of 60 minutes in operation.

(2nd deice and onward shall follow above conditions)

Page 44 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — DBT WBT DBT WBT
Page 44 · click to enlarge
Page 44

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

9 Operating Instructions

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 44)
Fig. 53
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 44)
Fig. 54

Thank you for purchasing Panasonic Air Conditioner

SAFETY PRECAUTIONS I Definition

Panasonic Air Conditioner (CS-E9DKEW) — SAFETY PRECAUTIONS I Definition diagram (page 44)
Fig. 55 · SAFETY PRECAUTIONS I Definition

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Installation Precautions Installation Precautions

Warning

Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classifi ed as below:

Do not install, remove and reinstall the unit by yourself. • Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.

Caution

  • This air conditioner must be earthed. Improper grounding will cause electric shock.
  • Ensure that the drainage piping is connected properly. Otherwise, water will leak.
  • Current leakage protection equipment must be installed. Otherwise, electric shock or fi re may occur.

This sign warns of death

or serious injury.

  • Do not install the unit in a potentially explosive atmosphere.

Operation Operation Precautions Precautions

This sign warns of injury

or damage to property.

Warning

The instructions to be followed are classifi ed by the following symbols:

  • Do not share power outlet.
  • Do not modify power cord.
  • Do not use an extension cord.
  • Do not operate with wet hands.
  • Do not insert fi nger or other objects into the indoor or outdoor unit.
  • Do not attempt to repair the unit by yourself.
  • Do not use rechargeable (Ni-Cd) batteries.
  • Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.
  • Use specifi ed supply cord.
  • If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualifi ed person in order to avoid a hazard.
  • Remove the batteries if the unit is not going to be use for a long period of time.
  • New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.

an action that is

PROHIBITED.

  • In case of emergency or abnormal condition (burnt, smell, etc) occurs, turn off the power supply.

Caution

actions that are COMPULSORY.

  • Do not wash the unit with water, benzene, thinner or scouring powder.
  • Do not use for other purposes such as preservation of food.
  • Do not use any combustible equipment at airfl ow direction.
  • Do not sit or place anything on the indoor or outdoor unit.
  • Do not expose directly to cold air for a long period.
  • Ventilate the room regularly.
  • Pay attention as to whether the installation rack is damaged after long period of usage.
  • Switch off the power supply before cleaning or servicing.
  • Turn off the power supply if the unit is not used for a long period of time.
Panasonic Air Conditioner (CS-E9DKEW) — Caution diagram (page 44)
Fig. 56 · Caution
Panasonic Air Conditioner (CS-E9DKEW) — Caution diagram (page 44)
Fig. 57 · Caution

Operation Condition (OC)

Use this air conditioner under the following temperature range.

DBTDry Bulb Temperature WBT: Wet Bulb Temperature

The appliance is not intended for use by young children or infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.

DBT WBT DBT WBT

Maximum Temperature (COOL) 32 23 43 26

Maximum Temperature (HEAT) 30 – 24 18

Minimum Temperature (COOL) 16 11 16 11

Minimum Temperature (HEAT) 16 – -5 -6

Show 4 more labels / short text on this page
This symbol denotes · These symbols denote · Safety Regulation · Indoor Outdoor
Page 45 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — Remote Control Remote Control Transmitter
Page 45 · click to enlarge
Page 45

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 45)
Fig. 58

PRODUCT OVERVIEW

Panasonic Air Conditioner (CS-E9DKEW) — PRODUCT OVERVIEW diagram (page 45)
Fig. 59

Indoor Unit ndoor Unit

Panasonic Air Conditioner (CS-E9DKEW) — Indoor Unit ndoor Unit diagram (page 45)
Fig. 60 · Indoor Unit ndoor Unit

Supersonic air purifying device

1. Pull out 2. Insert batteries (AAA or

R03)

3. Press CLOCK button

QUIET POWERFUL ION TIMER POWER

Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 61
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 62
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 63
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 64
4. Set current time
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 65
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 66
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 67
5. Press again to confi rm
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 45)
Fig. 68
  • Timer operation will be based on current time set.

Do not touch during operation

Outdoor Outdoor Unit Unit

  • The batteries can be used for approximately 1 year.

QUIET POWERFUL ION SUPER ALLERU-BUSTER TIMER POWER

  • The batteries must be recycled or disposed of properly.
  • Make sure it is not obstructed.
  • Maximum distances: 10m.
  • Certain fluorescent lights may interfere with signal transmission. Consult your dealer.

Remote Control Remote Control Transmitter

Panasonic Air Conditioner (CS-E9DKEW) — Remote Control Remote Control Transmitter diagram (page 45)
Fig. 69 · Remote Control Remote Control Transmitter
  • To operate the unit if the remote control is misplaced or malfunctioning.

Press until “beep” sound and release.

Press until “beep” sound and release.

Press again until “beep-beep” sound

Memory reset Clock setting

and release.

  • To OFF, press again the Auto OFF/ ON button.
Panasonic Air Conditioner (CS-E9DKEW) — Remote Control Remote Control Transmitter diagram (page 45)
Fig. 70 · Remote Control Remote Control Transmitter

G Operation delayed for few minutes after restart. ➤ This is a normal self protection control.

G Sound like water fl owing during operation. ➤ Caused by refrigerant fl ow inside.

G Mist emerges from indoor unit. ➤ Condensation effect due to cooling process.

G Noisy during operations. ➤ Installation work could be slanted or front panel didn’t close properly.

G Remote control/display does not work. ➤ Check whether batteries are correctly inserted or need replacement.

G The unit cannot operate. ➤ Check either circuit breaker is tripped or timer is used correctly.

G Outdoor unit emits water/steam. ➤ Condensation or evaporation happens at piping surface.

Show 34 more labels / short text on this page
I About · Remote Control Preparation · Air intake · Front panel · Auto OFF/ON button · Air filter · Receiver · Airflow direction louver · Discharged air · Ionizer · Indicator · Air inlet (rear) · Air inlet (side) · Remote Control Signal · Air outlet · Auto OFF/ON Button · LCD display · Action Operation · mode · Ion operation · Temperature setting · Press once Automatic · Operation · Operation mode · Off/On · Cooling Operation · Quiet operation · Powerful operation · Airflow direction adjustment · Fan speed selection · Heating Operation · Timer setting · Check · Troubleshooting
Page 46 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — Set the temperature. (16°C~30°C)
Page 46 · click to enlarge
Page 46

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 46)
Fig. 71

HOW TO OPERATE

Panasonic Air Conditioner (CS-E9DKEW) — HOW TO OPERATE diagram (page 46)
Fig. 72

Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry

AUTO - Automatic Operation

  • The unit will automatically select the operation mode according to the setting, outdoor and room temperature. During operation mode selection, power indicator blinks. For every 30 minutes, the operation mode is reselected.
Panasonic Air Conditioner (CS-E9DKEW) — Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry diagram (page 46)
Fig. 73 · Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry

HEAT - Heating Operation

Panasonic Air Conditioner (CS-E9DKEW) — Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry diagram (page 46)
Fig. 74 · Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry
  • Enables you to enjoy the warming effect at your preferred setting temperature.

Start the operation.

Panasonic Air Conditioner (CS-E9DKEW) — Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry diagram (page 46)
Fig. 75 · Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry
Panasonic Air Conditioner (CS-E9DKEW) — Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry diagram (page 46)
Fig. 76 · Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry
  • For cold air prevention, air might not blow out immediately and power indicator blinks when operation starts.
  • Also operates in defrost mode (maximum 10 minutes) where by the power indicator blinks. The melted frost is drained at outdoor unit and indoor fan is stopped.

Select the desired operation.

Panasonic Air Conditioner (CS-E9DKEW) — Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry diagram (page 46)
Fig. 77 · Auto, Heat, Cool, D ry Auto, Heat, Cool, Dry

COOL - Cooling Operation

  • Enables you to enjoy the cooling effect at your preferred setting temperature.

AUTO

HEAT DRY

COOL

DRY - Soft Dry Operation

  • Enables you to set the desired temperature at low fan speed which provides you with the dehumidifying surroundings.

Set the temperature. (16°C~30°C)

G Supersonic air purifying device (super alleru-buster) operates

automatically while the air conditioner is switched on.

G Powerful, Quiet and Ion operations could be activated in all

operation modes.

button again to stop the operation.

Panasonic Air Conditioner (CS-E9DKEW) — Set the temperature. (16°C~30°C) diagram (page 46)
Fig. 78 · Set the temperature. (16°C~30°C)

G To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.

Panasonic Air Conditioner (CS-E9DKEW) — Set the temperature. (16°C~30°C) diagram (page 46)
Fig. 79 · Set the temperature. (16°C~30°C)

G The room has a peculiar odour. ➤ This may be a damp smell emitted by the wall, carpet, furniture or

clothing in the room.

G Air conditioner does not cool or heat effi ciently. ➤ Ensure the temperature has been set correctly. ➤ Ensure windows and doors have been closed properly. ➤ Ensure fi lters are cleaned or replaced when necessary. ➤ Ensure inlet and outlet vents of the units have not been obstructed.

I Operation Details · G Press · Troubleshooting

Page 47 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — AIR SWING AIR SWING
Page 47 · click to enlarge
Page 47

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 47)
Fig. 80

HOW TO OPERATE

Panasonic Air Conditioner (CS-E9DKEW) — HOW TO OPERATE diagram (page 47)
Fig. 81
Panasonic Air Conditioner (CS-E9DKEW) — HOW TO OPERATE diagram (page 47)
Fig. 82

Powerful, Powerful, Quiet, Quiet, Ion, Fan Speed, Ion, Fan Speed, Air Swing Air Swing

POWERFUL

  • To achieve setting temperature quickly.

QUIET

  • To provide a quiet environment.
Panasonic Air Conditioner (CS-E9DKEW) — QUIET diagram (page 47)
Fig. 83

ION

QUIET QUIET

  • To provide fresh air effect by producing negative ions.
Panasonic Air Conditioner (CS-E9DKEW) — ION diagram (page 47)
Fig. 84

ION ION

Enables quiet operation.

  • Ion operation could be activated independently.

Enables ion operation.

Panasonic Air Conditioner (CS-E9DKEW) — ION ION diagram (page 47)
Fig. 85
  • Press

button to stop the operation.

FAN SPEED

POWERFUL POWERFUL

  • To provide you with the various fan speed selections.

Enables powerful operation.

  • There are 5 levels of fan speed in addition to automatic fan speed.
  • Automatic fan speed:

The speed of the indoor fan is

automatically adjusted according to the operation.

AIR SWING

FAN SPEE D FAN SPEED

  • To ventilate air in the room.
  • There are 5 selections in addition to automatic vertical air fl ow direction.

Select fan speed.

AIR SWING AIR SWING

  • If automatic vertical airfl ow direction has been set, the louver swings up and down automatically.
Panasonic Air Conditioner (CS-E9DKEW) — AIR SWING AIR SWING diagram (page 47)
Fig. 86

Adjust the vertical or horizontal airfl ow direction louver.

  • To ventilate air in the room.
  • There are 5 selections in addition to automatic horizontal air fl ow direction.
  • If automatic horizontal airfl ow direction has been set, the louver swings left and right automatically.

G Powerful and Quiet operations could not be activated at the

  • Please do not adjust the vertical and horizontal airfl ow direction louver manually.

same time.

G Powerful, Quiet and Ion operations could be cancelled by

pressing the respective button again.

Panasonic Air Conditioner (CS-E9DKEW) — AIR SWING AIR SWING diagram (page 47)
Fig. 87

G If you wish to have the cool air blowing directly on you, set the airfl ow direction downward but not for an excessive length of time,

as it may harm your health.

G Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating

operation than the desired temperature.

Panasonic Air Conditioner (CS-E9DKEW) — AIR SWING AIR SWING diagram (page 47)
Fig. 88

G ION indicator on the indoor unit is blinking. ➤ Press ION button twice. If the indicator is still blinking, please consult

the dealer.

G Indoor fan stops occasionally during Automatic Fan

➤ This is an advanced feature that helps to remove smell from the

Speed setting.

surrounding area during operation.

G Indoor fan stops occasionally during heating operation.

➤ To avoids unintended cooling effect.

I Operations Details · Troubleshooting

Page 48 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CHECK
Page 48 · click to enlarge
Page 48

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 48)
Fig. 89

HOW TO OPERATE

Panasonic Air Conditioner (CS-E9DKEW) — HOW TO OPERATE diagram (page 48)
Fig. 90

Timer Timer

TIMER

  • Use the ON timer to turn on the air conditioner at the desired time. This will give you a cooling or warming environment, e.g. when you return from work or wake up.
  • When the ON timer is set, operation will start up to 35 minutes before the actual set time.
Panasonic Air Conditioner (CS-E9DKEW) — TIMER diagram (page 48)
Fig. 91
  • Use the OFF timer to stop the air conditioner operation at the desired time. This can save electricity while you are going out or sleeping.
  • The set timer will repeat daily once it is set.

Select ON or OFF timer.

  • If there is a power failure, you can press SET button to restore the previous setting once the power is resumed.

Set the desired time.

  • If the timer is cancelled, you can restore the previous setting by pressing SET button.

CHECK

  • When there is error, the unit stops its operation and timer indicator blinks.
1. Press for 5 seconds.

Confi rm the setting.

CANCEL CANCEL Cancel the selected timer.

Panasonic Air Conditioner (CS-E9DKEW) — CHECK diagram (page 48)
Fig. 92
2. Browse for respective error code, where “beep” sounds are heard.
3. Turn off the power supply and call authorized distributor.

Unit might operate with limited function depending on error found. (Operation starts, 4 “beep” sound is heard)

G Ensure the clock on the remote control has been set

correctly.

G You could use the ON and OFF timers at the same time.

G To cancel either the ON or OFF timer, press

Panasonic Air Conditioner (CS-E9DKEW) — CHECK diagram (page 48)
Fig. 93

G Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.

G For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.

Panasonic Air Conditioner (CS-E9DKEW) — CHECK diagram (page 48)
Fig. 94

G TIMER indicator always on. ➤ Timer is activated and the setting will repeat itself daily.

G POWER indicator is blinking 35 minutes before ON

➤ The unit is determining the operation mode by sensing the room

timer is activated.

temperature. This happens when it has been set to AUTO operation mode.

Show 4 more labels / short text on this page
I Operation Details · , then press · or · Troubleshooting
Page 49 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — IONIZER IONIZER
Page 49 · click to enlarge
Page 49

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 49)
Fig. 95

CARE & CLEANING

Panasonic Air Conditioner (CS-E9DKEW) — CARE & CLEANING diagram (page 49)
Fig. 96
Panasonic Air Conditioner (CS-E9DKEW) — CARE & CLEANING diagram (page 49)
Fig. 97
  • Do not use benzene, thinner or scouring powder.

Switch off the power supply Switch off the power supply before cleaning before cleaning

  • Use soaps or neutral household detergent ( ≃ pH7) only.
  • Do not use water with temperature higher than 40°C.

FRONT PANEL FRONT PANEL

Raise and pull to remove. Wash and dry.

INDOOR UNIT

  • Wipe the unit gently with a soft, dry cloth.
Panasonic Air Conditioner (CS-E9DKEW) — INDOOR UNIT diagram (page 49)
Fig. 98
Panasonic Air Conditioner (CS-E9DKEW) — INDOOR UNIT diagram (page 49)
Fig. 99

AIR FILTER

AIR FILTER AIR FILTER

  • It is recommended to clean the air fi lters once every 2 weeks.
Panasonic Air Conditioner (CS-E9DKEW) — AIR FILTER diagram (page 49)
Fig. 100
Panasonic Air Conditioner (CS-E9DKEW) — AIR FILTER diagram (page 49)
Fig. 101

Vacuum, wash and dry.

  • Purchase the replacement fi lter if it is damaged.
Panasonic Air Conditioner (CS-E9DKEW) — AIR FILTER diagram (page 49)
Fig. 102

Part no.: CWD001144

SUPER ALLERU-BUSTER

  • It is recommended to clean the fi lter every 6 months.
  • Replace the fi lter every 3 years or purchase the replacement fi lter if it is damaged.

Part no.: CZ-SA13P

QUIET POWERFUL ION TIMER POWER

IONIZER

  • It is recommended to clean the ionizer every 6 months.
Panasonic Air Conditioner (CS-E9DKEW) — QUIET POWERFUL ION TIMER POWER diagram (page 49)
Fig. 103

I Preparation for extended

  • Operate the unit for 2~3 hours using ion operation to dry the internal parts.

IN D OOR UNIT INDOOR UNIT

SUPERSONIC AIR SUPERSONIC AIR PURIFYING D EVICE PURIFYING DEVICE

  • Turn off the power supply.

Wipe gently.

  • Remove the remote control batteries.

Vacuum the super alleru-buster fi lter.

  • This inspection is recommended before operating the air conditioner at every season.

IONIZER IONIZER

  • Check if the remote control batteries needed to be replaced.

Clean with cotton bud.

  • Ensure there is no obstruction at all air intake and outlet vents.
  • After the start of operation for 15 minutes, it is normal if the temperature differences between air intake and outlet vents at indoor unit is:-

Vacuum, wash and dry the frame.

Panasonic Air Conditioner (CS-E9DKEW) — IONIZER IONIZER diagram (page 49)
Fig. 104

G Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling or heating capacity, unpleasant smells and higher

energy consumption.

G The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an

authorized dealer to perform seasonal inspections in addition to regular cleaning.

G This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner

from being damaged by abnormally strong lightning activity, you may switch off the power supply.

Show 9 more labels / short text on this page
I Washing Instructions · Remove · Remove · Non-operation · I Pre-season Inspection · Remove · Operation Temperature · Cooling 8°C · Heating 14°C
Page 50 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 10.1. Safety Precautions
Page 50 · click to enlarge
Page 50

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

10 Installation Instructions

Required tools for Installation Works 1. Philips screw driver 5. Spanner 9. Gas leak detector 13. Multimeter 2. Level gauge 6. Pipe cutter 10. Measuring tape 14. Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3. Electric drill, hole core drill (ø70 mm)

7. Reamer 11. Thermometer 15. Vacuum pump
4. Hexagonal wrench (4 mm) 8. Knife 12. Megameter 16. Gauge manifold

10.1. Safety Precautions

  • Read the following “SAFETY PRECAUTIONS” carefully before installation.
  • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit

for the model to be installed.

  • The caution items stated here must be followed because these important contents are related to safety. The meaning of each

indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.

This indication shows the possibility of causing death or serious injury.

This indication shows the possibility of causing injury or damage to properties only.

The items to be followed are classified by the symbols:

Symbol with background white denotes item that is PROHIBITED from doing.

  • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and

maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.

1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6. Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.

9. When connecting the piping, do not allow air or any substances other than the specified refrigerant (R410A) to enter the refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in explosion and injury.
10. • When connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials.
  • Thickness of copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8

mm.

  • It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
Page 51 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 51 · click to enlarge
Page 51

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

1. The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire.
3. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.

1. Selection of the installation location. Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. 2. Power supply connection to the room air conditioner. Connect the power supply cord of the room air conditioner to the mains using one of the following method. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. 1. Power supply connection to the receptacle using a power plug.

Use an approved 15A/16A power plug with earth pin for the connection to the socket.

2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent

connection. It must be a double pole switch with a minimum 3.5 mm contact gap. 3. Do not release refrigerant. Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite. 4. Installation work. It may need two people to carry out the installation work. 5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.

Page 52 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — OUTDOOR UNIT
Page 52 · click to enlarge
Page 52

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 52)
Fig. 105

Indoor/Outdoor Unit Installation Diagram

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 52)
Fig. 106

CZ-3F5, 7BP (E9DK)

CZ-4F5, 7, 10BP (E12DK)

SELECT THE BEST LOCATION

INDOOR UNIT

  • There should not be any heat source or steam near the

unit.

  • There should not be any obstacles blocking the air

circulation.

  • A place where air circulation in the room is good.
  • A place where drainage can be easily done.
  • A place where noise prevention is taken into consideration.
  • Do not install the unit near the door way.
  • Ensure the spaces indicated by arrows from the wall,

ceiling, fence or other obstacles.

  • Recommended installation height for indoor unit shall be

at least 2.3 m.

OUTDOOR UNIT

  • If an awning is built over the unit to prevent direct

sunlight or rain, be careful that heat radiation from the condenser is not obstructed.

  • This illustration is for explanation purposes only.

The indoor unit will actually face a different way.

  • There should not be any animal or plant which could be

affected by hot air discharged.

  • Keep the spaces indicated by arrows from wall, ceiling,

fence or other obstacles.

  • Do not place any obstacles which may cause a short

circuit of the discharged air.

  • If piping length is over the rated length, additional

refrigerant should be added as shown in the table.

Panasonic Air Conditioner (CS-E9DKEW) — OUTDOOR UNIT diagram (page 52)
Fig. 107

Attached accessories · Applicable piping kit

Page 53 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 10.2.4. INDOOR UNIT INSTALLATION
Page 53 · click to enlarge
Page 53

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

10.2. Indoor Unit

10.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING

10.2.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section)

1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.

10.2.2. HOW TO FIX INSTALLATION PLATE

3. Cut the sleeve until it extrudes about 15 mm from the wall.

When the wall is hollow, please be sure to use the sleeve for tube ass’y to prevent dangers caused by mice biting the connecting cable.

The mounting wall is strong and solid enough to prevent it from the vibration.

Panasonic Air Conditioner (CS-E9DKEW) — 10.2.2. HOW TO FIX INSTALLATION PLATE diagram (page 53)
Fig. 108
4. Finish by sealing the sleeve with putty or caulking compound at the final stage.
Panasonic Air Conditioner (CS-E9DKEW) — 10.2.2. HOW TO FIX INSTALLATION PLATE diagram (page 53)
Fig. 109

The centre of installation plate should be at more than 450 mm at right and left of the wall.

The distance from installation plate edge to ceiling should more than 67 mm.

From installation plate left edge to unit’s left side is 74 mm.

From installation plate right edge to unit’s right is 94 mm.

:

For left side piping, piping connection for liquid should be about 15 mm from this line. For left side piping, piping connection for gas should be about 45 mm from this line. For left side piping, piping connection cable should be about 800 mm from this line

10.2.4. INDOOR UNIT INSTALLATION

:

1. For the right rear piping

:

Panasonic Air Conditioner (CS-E9DKEW) — 10.2.4. INDOOR UNIT INSTALLATION diagram (page 53)
Fig. 110
1. Mount the installation plate on the wall with 5 screws or

more. (If mounting the unit on the concrete wall consider using anchor bolts.)

  • Always mount the installation plate horizontally by

aligning the marking-off line with the thread and using a level gauge.

2. For the right and right bottom piping
2. Drill the piping plate hole with ø70 mm hole-core drill.
Panasonic Air Conditioner (CS-E9DKEW) — 10.2.4. INDOOR UNIT INSTALLATION diagram (page 53)
Fig. 111
  • Line according to the arrows marked on the lower left

and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 150 mm and 125 mm for left and right hole respectively.

  • Drill the piping hole at either the right or the left and the

hole should be slightly slanted to the outdoor side.

Page 54 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 54 · click to enlarge
Page 54

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

3. For the embedded piping
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 112
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 113
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 114
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 115
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 116

(This can be used for left rear piping & left bottom piping also.)

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 117
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 118
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 119
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 54)
Fig. 120
Page 55 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT
Page 55 · click to enlarge
Page 55

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 55)
Fig. 121

10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT

1. The inside and outside connecting cable can be connected

without removing the front grille.

2. Connecting cable between indoor unit and outdoor unit

shall be approved polychloroprene sheathed 4 × 1.5 mm2

flexible cord, type designation 245 IEC 57 or heavier cord.

  • Ensure the color of wires of outdoor unit and the

terminal Nos. are the same to the indoor’s respectively.

  • Earth lead wire shall be longer than the other lead wires

as shown in the figure for the electrical safety in case of the slipping out of the cord from the anchorage.

Panasonic Air Conditioner (CS-E9DKEW) — 10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT diagram (page 55)
Fig. 122
Panasonic Air Conditioner (CS-E9DKEW) — 10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT diagram (page 55)
Fig. 123
  • Secure the cable onto the control board with the holder

(clamper).

Panasonic Air Conditioner (CS-E9DKEW) — 10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT diagram (page 55)
Fig. 124
Page 56 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
Page 56 · click to enlarge
Page 56

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

INSTALLATION OF SUPER ALLERU-BUSTER FILTER

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 56)
Fig. 125
1. Open the front panel.
2. Remove the air filter.
3. Remove Supersonic air purifying device.
4. Open the Supersonic air purifying device frame.
5. Insert the super alleru-buster filter and close the Supersonic

air purifying device frame as show in illustration at right.

HOW TO TAKE OUT FRONT GRILLE

Please follow the steps below to take out front grille if necessary such as when servicing.

1. Open the intake grille and remove the screw at the front of the front grille.
2. Set the vertical airflow direction louvers to the horizontal position.
3. Slide down the 2 caps on the front grille as shown in the illustration below, and then remove the 2 mounting screws.
4. Pull the lower section of the front grille towards you to remove the front grille.
Panasonic Air Conditioner (CS-E9DKEW) — HOW TO TAKE OUT FRONT GRILLE diagram (page 56)
Fig. 126

When reinstalling the front grille, first set the vertical airflow direction louver to the horizontal position and then carry out above steps 2 - 3 in the reverse order.

AUTO SWITCH OPERATION

The below operations will be performed by pressing the “AUTO” switch.

1. AUTO OPERATION MODE

The Auto operation will be activated immediately once the Auto Switch is pressed.

2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)

The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. A “beep” sound will occur at the fifth sec., in order to identify the starting of Test Run operation

3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF

The ON/OFF of remote controller receiving sound can be change over by pressing the following step:

a. Release the Auto Switch after Test Run operation is activated.

b. Then, within 20 sec., after a., press Auto Switch for more than 5 sec.

A “beep” “beep” sound will occur at the fifth sec., then release the Auto Switch.

c. Within 20 sec. after b., press Auto Switch again. Everytime Auto Switch is pressed (within 20 sec. interval), remote

controller receiving sound status will be reversed between ON and OFF.

Long “beep” sound indicates that remote controller receiving sound is OFF.

Short “beep” sound indicates that remote controller receiving sound is ON.

Panasonic Air Conditioner (CS-E9DKEW) — 3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF diagram (page 56)
Fig. 127
Page 57 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CUTTING AND FLARING THE PIPING
Page 57 · click to enlarge
Page 57

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

10.3. Outdoor Unit

10.3.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section)

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 57)
Fig. 128

10.3.2. INSTALL THE OUTDOOR UNIT

  • After selecting the best location, start installation according

to Indoor/Outdoor Unit Installation Diagram.

1. Fix the unit on concrete or rigid frame firmly and horizontally

by bolt nut. (ø10 mm).

2. When installing at roof, please consider strong wind and

earthquake. Please fasten the installation stand firmly with bolt or nails.

10.3.3. CONNECTING THE PIPING

Connecting The Piping To Indoor Unit

Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe. (In case of using long piping)

  • Align the center of piping and sufficiently tighten the flare nut with fingers.
  • Further tighten the flare nut with torque wrench in specified torque as stated in the table.

MODEL Piping size (Torque) Gas Liquid E9DK 3/8” (42 N.m) 1/4” (18 N.m) E12DK 1/2” (55 N.m) 1/4” (18 N.m)

Panasonic Air Conditioner (CS-E9DKEW) — 10.3.3. CONNECTING THE PIPING diagram (page 57)
Fig. 129

Connecting The Piping To Outdoor Unit

Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the flare nut (located at valve) onto the copper pipe.

Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table.

CUTTING AND FLARING THE PIPING

Panasonic Air Conditioner (CS-E9DKEW) — CUTTING AND FLARING THE PIPING diagram (page 57)
Fig. 130
1. Please cut using pipe cutter and then remove the burrs.
2. Remove the burrs by using reamer. If burrs is not

removed, gas leakage may be caused.

Turn the piping end down to avoid the metal powder entering the pipe.

3. Please make flare after inserting the flare nut onto the

copper pipes.

Connect the piping

Page 58 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CAUTION
Page 58 · click to enlarge
Page 58

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

10.3.4. EVACUATION OF THE EQUIPMENT

WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 58)
Fig. 131
1. Connect a charging hose with a push pin to the Low and High side of a charging set and the service port of the 3-way valve.
  • Be sure to connect the end of the charging hose with the push pin to the service port.
2. Connect the center hose of the charging set to a vacuum pump with check valve, or vacuum pump and vacuum pump adaptor.
3. Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 cmHg (0 MPa) to

-76 cmHg (-0.1 MPa). Then evacuate the air approximately ten minutes.

4. Close the Low side valve of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not

move after approximately five minutes.

5. Disconnect the charging hose from the vacuum pump and from the service port of the 3-way valve.
6. Tighten the service port caps of the 3-way valve at torque of 18 N.m with a torque wrench.
7. Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to “OPEN” using a hexagonal

wrench (4 mm).

8. Mount valve caps onto the 2-way valve and the 3-way valve.
  • Be sure to check for gas leakage.

CAUTION

  • If gauge needle does not move from 0 cmHg (0 MPa) to -76 cmHg (-0.1 MPa), in step 3 above take the following measure:
  • If the leak stops when the piping connections are tightened further, continue working from step 3.
  • If the leak does not stop when the connections are retightened, repair the location of leak.
  • Do not release refrigerant during piping work for installation and reinstallation. Take care of the liquid refrigerant, it may cause

frostbite.

Page 59 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — DISPOSAL OF OUTDOOR UNIT DRAIN WATER
Page 59 · click to enlarge
Page 59

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

10.3.5. CONNECT THE CABLE TO THE OUTDOOR UNIT

(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 59)
Fig. 132
1. Remove the control board cover from the unit by loosening

the screw.

2. Connecting cable between indoor unit and outdoor unit

shall be approved polychloroprene sheathed 4 × 1.5 mm2

flexible cord, type designation 245 IEC 57 or heavier cord.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 59)
Fig. 133
3. Secure the cable onto the control board with the holder

(clamper).

4. Cable connection to the power supply through knife switch

(Disconnecting means).

  • Connect the approved polychloroprene sheathed power

supply cable (1.5 mm2), type designation 245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cable to knife switch (Disconnecting means).

Knife switch (Disconnecting means) should have minimum 3 mm contact gap.

− Secure the cable onto the control board with the

holder (clamper).

10.3.6. PIPE INSULATION

1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap

the insulated piping end to prevent water from going inside the piping.

2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM

with thickness 6 mm or above.

DISPOSAL OF OUTDOOR UNIT DRAIN WATER

Panasonic Air Conditioner (CS-E9DKEW) — DISPOSAL OF OUTDOOR UNIT DRAIN WATER diagram (page 59)
Fig. 134
  • If a drain elbow is used, the unit should be placed on a

stand which is taller than 3 cm.

  • If the unit is used in an area where temperature falls below

0°C for 2 or 3 days in succession, it is recommended not to use a drain elbow, for the drain water freezes and the fan will not rotate.

Page 60 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CHECK ITEMS
Page 60 · click to enlarge
Page 60

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

CHECK THE DRAINAGE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 60)
Fig. 135
  • Open front panel and remove air filters.

(Drainage checking can be carried out without removing the front grille.)

  • Pour a glass of water into the drain tray-styrofoam.
  • Ensure that water flows out from drain hose of the indoor

unit.

EVALUATION OF THE PERFORMANCE

Panasonic Air Conditioner (CS-E9DKEW) — EVALUATION OF THE PERFORMANCE diagram (page 60)
Fig. 136
  • Operate the unit at cooling operation mode for fifteen

minutes or more.

  • Measure the temperature of the intake and discharge air.
  • Ensure the difference between the intake temperature and

the discharge is more than 8°C.

CHECK ITEMS

Is the indoor unit properly hooked to the installation plate?

Is there any gas leakage at flare nut connections?

Is the power supply voltage complied with rated value?

Has the heat insulation been carried out at flare nut connection?

Is there any abnormal sound?

Is the connecting cable being fixed to terminal board firmly?

Is the cooling operation normal?

Is the connecting cable being clamped firmly?

Is the thermostat operation normal?

Is the drainage OK? (Refer to “Check the drainage” section)

Is the remote control’s LCD operation normal?

Is the super alleru-buster filter is installed?

Is the earth wire connection properly done?

Page 61 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 61 · click to enlarge
Page 61

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11 Installation And Servicing Air Conditioner Using R410A

11.1. Outline

11.1.1. About R410A Refrigerant

1. Converting air conditioners to R410A

Since it was declared in1974 that chlorofluorocarbons (CFC), hydro chlorofluorocarbons (HCFC) and other substances pose a destructive danger to the ozone layer in the earth´s upper stratosphere (20 to 40 km above the earth), measures have been taken around the world to prevent this destruction. The R22 refrigerant which has conventionally been used in ACs is an HCFC refrigerant and, therefore, possesses this ozone- destroying potential. International regulations (the Montreal Protocol on Ozone-Damaging Substances) and the domestic laws of various countries call for the early substitution of R22 by a refrigerant which will not harm the ozone layer.

  • In ACs, the HFC refrigerant which has become the mainstream alternative is called <a href="http://R410A.Com" rel="nofollow noopener" target="_blank">R410A.Com</a>pared with R22, the

pressure of R410A is approximately 1.6 times as high at the same refrigerant temperature, but the energy efficiency is about the same. Consisting of hydrogen (H), fluorine (F) and carbon (C), R410A is an HFC refrigerant. Another typical HFC refrigerant is R407C. While the energy efficiency of R407C is somewhat inferior to that of R410A, it offers the advantage of having pressure characteristics which are about the same as those of R22, and is used mainly in packaged ACs.

2. The characteristics of HFC (R410A) refrigerants

a. Chemical characteristics

The chemical characteristics of R410A are similar to those of R22 in that both are chemically stable, non-flammable refrigerants with low toxicity. However, just like R22, the specific gravity of R410A gas is heavier than that of air. Because of this, it can cause an oxygen deficiency if it leaks into a closed room since it collects in the lower area of the room. It also generates toxic gas when it is directly exposed to a flame, so it must be used in a well ventilated environment where it will not collect.

Table 1 Physical comparison of R410A and R22

R410A R22 Composition (wt%) R32/R125 (50/50) R22 (100) Boiling point (°C) -51.4 -40.8 Vaporizing pressure (25°C) 1.56 Mpa (15.9 kgf/cm2) 0.94 Mpa (9.6 kgf/cm2) Saturated vapor density 64.0 kg/m3 44.4 kg/m3

Flammability Non-flammable Non-flammable Ozone-destroying point (ODP) 0 0.055 Global-warming point (GWP) 1730 1700

b. Compositional change (pseudo-azeotropic characteristics)

R410A is a pseudo-azeotropic mixture comprising the two components R32 and R125. Multi-component refrigerants with these chemical characteristics exhibit little compositional change even from phase changes due to vaporization (or condensation), which means that there is little change in the circulating refrigerant composition even when the refrigerant leaks from the gaseous section of the piping. Accordingly, R410A can be handled in almost the same manner as the single-component refrigerant R22. However, when charging, because there is a slight change in composition between the gas phase and the liquid phase inside a cylinder or other container, charging should basically begin with the liquid side.

c. Pressure characteristics

As seen in Table 2, the gas pressure of R410A is approximately 1.6 times as high as that of R22 at the same refrigerant temperature, which means that special R410A tools and materials with high-pressure specifications must be used for all refrigerant piping work and servicing.

Table 2 Comparison of R410A and R22 saturated vapor density

Unit: MPa Refrigerant Temperature (°C) R410A R22 -20 0.30 0.14 0 0.70 0.40 20 1.35 0.81 40 2.32 1.43 60 3.73 2.33 65 4.15 2.60

Page 62 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.2.1. Necessary Tools
Page 62 · click to enlarge
Page 62

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

d. R410A refrigerating machine oil

Conventionally, mineral oil or a synthetic oil such as alkylbenzene has been used for R22 refrigerating machine oil. Because of the poor compatibility between R410A and conventional oils like mineral oil, however, there is a tendency for the refrigerating machine oil to collect in the refrigerating cycle. For this reason, polyester and other synthetic oils which have a high compatibility with R410A are used as refrigerating machine oil. Because of the high hygroscopic property of synthetic oil, more care must be taken in its handling than was necessary with conventional refrigerating machine oils. Also, these synthetic oils will degrade if mixed with mineral oil or alkylbenzene, causing clogging in capillary tubes or compressor malfunction. Do not mix them under any circumstances.

11.1.2. Safety Measures When Installing/Servicing Refrigerant Piping

Cause the gas pressure of R410A is approximately 1.6 times as high as that of R22, a mistake in installation or servicing could result in a major accident. It is essential that you use R410A tools and materials, and that you observe the following precautions to ensure safety.

1. Do not use any refrigerant other than R410A in ACs that have been used with R410A.
2. If any refrigerant gas leaks while you are working, ventilate the room. Toxic gas may be generated if refrigerant gas is exposed

to a direct flame.

3. When installing or transferring an AC, do not allow any air or substance other than R410A to mix into the refrigeration cycle. If

it does, the pressure in the refrigeration cycle can become abnormally high, possibly causing an explosion and/or injury.

4. After finishing the installation, check to make sure there is no refrigerant gas leaking.
5. When installing or transferring an AC, follow the instructions in the installation instructions carefully. Incorrect installation can

result in an abnormal refrigeration cycle or water leakage, electric shock, fire, etc.

6. Do not perform any alterations on the AC unit under any circumstances. Have all repair work done by a specialist. Incorrect

repairs can result in an water leakage, electric shock, fire, etc.

11.2. Tools For Installing/Servicing Refrigerant Piping

11.2.1. Necessary Tools

In order to prevent an R410A AC from mistakenly being charged with any other refrigerant, the diameter of the 3-way valve service port on the outdoor unit has been changed. Also, to increase its ability to withstand pressure, the opposing dimensions have been changed for the refrigerant pipe flaring size and flare nut. Accordingly, when installing or servicing refrigerant piping, you must have both the R410A and ordinary tools listed below.

Table 3 Tools for installation, transferring or replacement Type of work Ordinary tools R410A tools Flaring Flaring tool (clutch type), pipe cutter, reamer

Copper pipe gauge for clearance Adjustment, flaring tool (clutch type)*1) Bending, connecting pipes Torque wrench (nominal diameter 1/4, 3/8,1/2). Fixed spanner (opposing sides 12 mm, 17 mm, 19 mm). Adjustable wrench, Spring bender Air purging Vacuum pump. Hexagonal wrench (opposing sides 4 mm)

Manifold gauge, charging hose, vacuum pump adaptor Gas leak inspection Gas leak inspection fluid or soapy water Electric gas leak detector for HFC refrigerant*2)

*1) You can use the conventional (R22) flaring tool. If you need to buy a new tool, buy the R410A type.

*2) Use when it is necessary to detect small gas leaks.

For other installation work, you should have the usual tools, such as screwdrivers (+,-), a metal-cutting saw, an electrical drill, a hole core drill (65 or 70 dia.), a tape measure, a level, a thermometer, a clamp meter, an insulation tester, a voltmeter, etc.

Table 4 Tools for serving Type of work Ordinary tools R410A tools Refrigerant charging Electronic scale for refrigerant charging. Refrigerant cylinder. Charging orifice and packing for refrigerant cylinder Brazing (Replacing refrigerating cycle part*1)

Nitrogen blow set (be sure to use nitrogen blowing for all brazing), and brazing machine

*1) Always replace the dryer of the outdoor unit at the same time. The replacement dryer is wrapped in a vacuum pack. Replace it last among the refrigerating cycle parts. Start brazing as soon as you have opened the vacuum pack, and begin the vacuuming operation within 2 hours.

Page 63 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 63 · click to enlarge
Page 63

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11.2.2. R410A Tools

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 63)
Fig. 137
1. Copper tube gauge for clearance adjustment

(used when flaring with the conventional flaring tool (clutch type))

  • This gauge makes it easy to set the clearance for the

copper tube to 1.0-1.5 mm from the clamp bar of the flaring tool.

Fig. 1 Copper tube gauge for clearance adjustment

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 63)
Fig. 138
2. Flaring tool (clutch type)
  • In the R410A flaring tool, the receiving hole for the

clamp bar is enlarged so the clearance from the clamp bar can be set to 0-0.5 mm, and the spring inside the tool is strengthened to increase the strength of the pipe- expanding torque. This flaring tools can also be used with R22 piping, so we recommend that you select it if you are buying a new flaring tool.

Fig. 2 Flaring tool (clutch type)

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 63)
Fig. 139
3. Torque wrenches

Fig. 3 Torque wrenches

Table 5 Conventional wrenches R410A wrenches For 1/4 (opposite side x torque) 17 mm x 18 N.m (180 kgf.cm) 17 mm x 18 N.m (180 kgf.cm) For 3/8 (opposite side x torque) 22 mm x 42 N.m (420 kgf.cm) 22 mm x 42 N.m (420 kgf.cm) For 1/2 (opposite side x torque) 24 mm x 55 N.m (550 kgf.cm) 26 mm x 55 N.m (550 kgf.cm)

4. Manifold gauge
  • Because the pressure is higher for the R410A type, the conventional type cannot be used.

Table 6 Difference between R410A and conventional high / low-pressure gauges

Conventional gauges R410A gauges High-pressure gauge (red) -76 cmHg - 35 kgf/cm3 -0.1 - 5.3 Mpa -76 cmHg - 53 kgf/cm3

Low-pressure gauge (blue) -76 cmHg - 17 kgf/cm3 -0.1 - 3.8 Mpa -76 cmHg - 38 kgf/cm3

  • The shape of the manifold ports has been changed to prevent the possibility of mistakenly charging with another type of

refrigerant.

Table 7 Difference between R410A and conventional manifold port size

Conventional gauges R410A gauges Port size 7/16 UNF 20 threads 1/2 UNF 20 threads

Page 64 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 64 · click to enlarge
Page 64

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

5. Charging hose
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 64)
Fig. 140
  • The pressure resistance of the charging hose has been

raised to match the higher pressure of R410A. The hose material has also been changed to suit HFC use, and the size of the fitting has been changed to match the manifold ports.

Fig. 4 Manifold gauge charging hose

Table 8 Difference between R410A and conventional charging hoses

Conventional hoses R410A hoses Pressure resistance

Working pressure 3.4 MPa (35 kgf/cm3) 5.1 MPa (52 kgf/cm3) Bursting pressure 17.2 MPa (175 kgf/cm3) 27.4 MPa (280 kgf/cm3) Material NBR rubber HNBR rubber Nylon coating inside

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 64)
Fig. 141
6. Vacuum pump adaptor
  • When using a vacuum pump for R410A, it is necessary

to install an electromagnetic valve to prevent the vacuum pump oil from flowing back into the charging hose. The vacuum pump adaptor is installed for that purpose. if the vacuum pump oil (mineral oil) becomes mixed with R410A, it will damage the unit.

Fig. 5 Vacuum pump adaptor

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 64)
Fig. 142
7. Electric gas leak detector for HFC refrigerant
  • The leak detector and halide torch that were used with

CFC and HCFC cannot be used with R410A (because there is no chlorine in the refrigerant).

  • The present R134a leak detector can be used, but the

detection sensitivity will be lower (setting the sensitivity for R134a at 1, the level for R410A will drop to 0.6).

  • For detecting small amounts of gas leakage, use the

electric gas leak detector for HFC refrigerant. (Detection sensitivity with R410A is about 23 g/year).

Fig. 6 Electric gas leak detector for HFC refrigerant

Page 65 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.2.3. R410A Tools Which Are Usable for R22 Models
Page 65 · click to enlarge
Page 65

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

8. Electronic scale for refrigerant charging
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 65)
Fig. 143
  • Because of the high pressure and fast vaporizing speed

of R410A, the refrigerant cannot be held in a liquid phase inside the charging cylinder when charging is done using the charging cylinder method, causing bubbles to form in the measurement scale glass and making it difficult to see the reading. (Naturally, the conventional R22 charging cylinder cannot be used because of the differences in the pressure resistance, scale gradation, connecting port size, etc.)

  • The electronic scale has been strengthened by using a

structure in which the weight detector for the refrigerant cylinder is held by four supports. It is also equipped with two connection ports, one for R22 (7/16 UNF, 20 threads) and one for R410A (1/2 UNF, 20 threads), so it can also be used for conventional refrigerant charging.

Fig. 7 Electronic scale for refrigerant charging

  • There are two types of electronic scales, one for 10-kg

cylinders and one for 20-kg cylinders. (The 10-kg cylinder is recommended.)

Refrigerant charging is done manually by opening and closing the valve.

9. Refrigerant cylinders
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 65)
Fig. 144
  • The R410A cylinders are labeled with the refrigerant

name, and the coating color of the cylinder protector is pink, which is the color stipulated by ARI of the U.S.

  • Cylinders equipped with a siphon tube are available to

allow the cylinder to stand upright for liquid refrigerant charging.

Fig. 8 Refrigerant cylinders

10. Charging orifice and packing for refrigerant cylinders
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 65)
Fig. 145
  • The charging orifice must match the size of the charging

hose fitting (1/2 UNF, 20 threads).

  • The packing must also be made of an HFC-resistant

material.

Fig. 9 Charging orifice and packing

11.2.3. R410A Tools Which Are Usable for R22 Models

Table 9 R410A tools which are usable for R22 models

R410A tools Usable for R22 models (1) Copper tube gauge for clearance adjustment OK (2) Flaring tool (clutch type) OK (3) Manifold gauge NG (4) Charging hose NG (5) Vacuum pump adaptor OK (6) Electric gas leak detector for HFC refrigerant NG (7) Electronic scale for refrigerant charging OK (8) Refrigerant cylinder NG (9) Charging orifice and packing for refrigerant cylinder NG

Page 66 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.3.2. Processing and Connecting Piping Materials
Page 66 · click to enlarge
Page 66

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11.3. Refrigerant Piping Work

11.3.1. Piping Materials

It is recommended that you use copper and copper alloy jointless pipes with a maximum oil adherence of 40 mg/10m. Do not use pipes that are crushed, deformed, or discolored (especially the inside surface). If these inferior pipes are used, impurities may clog the expansion valves or capillaries. Because the pressure of ACs using R410A is higher than those using R22, it is essential that you select materials that are appropriate for these standards. The thickness of the copper tubing used for R410A is shown in Table 10. Please be aware that tubing with a thickness of only 0.7 mm is also available on the market, but this should never be used.

Table 10 Copper tube thickness (mm) Soft pipe Thickness (mm) Nominal diameter Outside diameter (mm) R410A (Reference) R22 1/4 6.35 0.80 0.80 3/8 9.52 0.80 0.80 1/2 12.7 0.80 0.80

11.3.2. Processing and Connecting Piping Materials

When working with refrigerant piping, the following points must be carefully observed: no moisture od dust must be allowed to enter the piping, and there must be no refrigerant leaks.

Panasonic Air Conditioner (CS-E9DKEW) — 11.3.2. Processing and Connecting Piping Materials diagram (page 66)
Fig. 146 · 11.3.2. Processing and Connecting Piping Materials
1. Procedure and precautions for flaring work

a. Cut the pipe

Use a pipe cutter, and cut slowly so the pipe will not be deformed.

b. Remove burrs and clean shavings from the cut surface

If the shape of the pipe end is poor after removing burrs, or if shavings adhere to the flared area, it may lead to refrigerant leaks. To prevent this, turn the cut surface downward and remove burrs, then clean the surface, carefully.

Fig. 10 Flaring dimensions

c. Insert the flare nut (be sure to use the same nut that is

used on the AC unit)

d. Flaring

Check the clamp bar and the cleanliness of the copper pipe. Be sure to use the clamp bar to do the flaring with accuracy. Use either an R410A flaring tool, or a conventional flaring tool. flaring tools come in different sizes, so be sure to check the size before using. When using a conventional flaring tool, use the copper pipe gauge for clearance adjustment, etc., to ensure the correct A dimension (see Fig. 10)

Panasonic Air Conditioner (CS-E9DKEW) — 11.3.2. Processing and Connecting Piping Materials diagram (page 66)
Fig. 147 · 11.3.2. Processing and Connecting Piping Materials

Fig. 11 Relation between the flare nut structure and flaring tool end

Page 67 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.3.3. Storing and Managing Piping Materials
Page 67 · click to enlarge
Page 67

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Table 11 R410A flaring dimensions Nominal diameter

A (mm) R410A flaring tool, clutch type

Conventional flaring tool Clutch type Wing-nut type 1/4 6.35 0.8 0 - 0.5 1.0 - 1.5 1.5 - 2.0 3/8 9.52 0.8 0 - 0.5 1.0 - 1.5 1.5 - 2.0 1/2 12.70 0.8 0 - 0.5 1.0 - 1.5 2.0 - 2.5

Table 12 R22 flaring dimensions Nominal diameter

A (mm) R410A flaring tool, clutch type

Conventional flaring tool Clutch type Wing-nut type 1/4 6.35 0.8 0 - 0.5 0.5 - 1.0 1.0 - 1.5 3/8 9.52 0.8 0 - 0.5 0.5 - 1.0 1.0 - 1.5 1/2 12.70 0.8 0 - 0.5 0.5 - 1.0 1.5 - 2.0

Table 13 R410A flare and flare nut dimensions Unit: mm Nominal diameter

A +0, -0.4 B dimension

width 1/4 6.35 0.8 9.1 9.2 6.5 13 17 3/8 9.52 0.8 13.2 13.5 9.7 20 22 1/2 12.70 0.8 16.6 16.0 12.9 23 26

Table 14 R22 flare and flare nut dimensions Unit: mm Nominal diameter

A +0, -0.4 B dimension

width 1/4 6.35 0.8 9.0 9.2 6.5 13 17 3/8 9.52 0.8 13.0 13.5 9.7 20 22 1/2 12.70 0.8 16.2 16.0 12.9 20 24

2. Procedure and precautions for flare connection

a. Check to make sure there is no scratches, dust, etc., on the flare and union.

b. Align the flared surface with the axial center of the union.

c. Use a torque wrench, and tighten to the specified torque. The tightening torque for R410A is the same as the conventional

torque value for R22. Be careful, because if the torque is too weak, it may lead to a gas leak. If it is too strong, it may split the flare nut or make it impossible to remove the flare nut.

Table 15 R410A tightening torque Nominal diameter

Torque wrench tightening torque

N.m (kgf.cm) 1/4 6.35 14 - 18 (140 - 180) 18 (180) 3/8 9.52 33 - 42 (330 -420) 42 (420) 1/2 12.70 55 (550) 55 (550)

N.m (kgf.cm)

11.3.3. Storing and Managing Piping Materials

1. Types of piping and their storage

The following is a general classification of the refrigerant pipe materials used for ACs.

Panasonic Air Conditioner (CS-E9DKEW) — 11.3.3. Storing and Managing Piping Materials diagram (page 67)
Fig. 148 · 11.3.3. Storing and Managing Piping Materials

Because the gas pressure of R410A is approximately 1.6 times as high as that of R22, copper pipes with the thickness shown in Table 10, and with minimal impurities must be used. Care must also be taken during storage to ensure that pipes are not crushed, deformed, or scratched, and that no dust, moisture or other substance enters the pipe interior. When storing sheathed copper pipes or plain copper pipes, seal the openings by pinching or taping them securely.

2. Makings and management

a. Sheathed copper pipes and copper-element pipes

When using these pipes, check to make sure that they are the stipulated thickness. For flare nuts, be sure to used the same nut that is used on the AC unit.

Show 22 more labels / short text on this page
Outside diameter · Wall thickness · (mm) · (mm) · Outside diameter · Wall thickness · (mm) · (mm) · Outside diameter (mm) · Wall thickness · C dimension · D dimension · Flare nut · (mm) · Outside diameter (mm) · Wall thickness · C dimension · D dimension · Flare nut · (mm) · Outside diameter (mm) · Tightening torque
Page 68 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.4. Installation, Transferring, Servicing
Page 68 · click to enlarge
Page 68

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

b. Copper pipes

Use only copper pipes with the thickness given in table 10, and with minimal impurities. Because the surface of the pipe is exposed, you should take special care, and also take measures such as marking the pipes to make sure they are easily distinguished from other piping materials, to prevent mistaken use.

3. Precautions during refrigerant piping work

Take the following precautions on-site when connecting pipes. (Keep in mind that the need to control the entry of moisture and dust is even more important that in conventional piping).

a. Keep the open ends of all pipes sealed until connection with AC equipment is complete.

b. Take special care when doing piping work on rainy days. The entering of moisture will degrade the refrigerating machine oil,

and lead to malfunctions in the equipment.

c. Complete all pipe connections in as short a time as possible. If the pipe must be left standing for a long time after removing

the seal, it must be thoroughly purged with nitrogen, or dried with a vacuum pump.

11.4. Installation, Transferring, Servicing

11.4.1. Inspecting Gas Leaks with a Vacuum Pump for New Installations (Using New Refrigerant Piping)

1. From the viewpoint of protecting the global environment, please do not release refrigerant into the atmosphere.

a. Connect the projecting side (pin-pushing side) of the charging hose for the manifold gauge to the service port of the 3-way

valve. (1)

b. Fully open the handle Lo of the manifold gauge and run the vacuum pump. (2) (If the needle of the low-pressure gauge

instantly reaches vacuum, re-check step a).)

c. Continue the vacuum process for at least 15 minutes, then check to make sure the low-pressure gauge has reached -0.1

MPa (-76 cmHg). Once the vacuum process has finished, fully close the handle Lo of the manifold gauge and stop the vacuum pump operation, then remove the charging hose that is connected to the vacuum pump adaptor. (Leave the unit in that condition for 1-2 minutes, and make sure that the needle of the manifold gauge does not return.) (2) and (3)

d. Turn the valve stem of the 2-way valve 90° counter-clockwise to open it, then, after 10 seconds, close it and inspect for a

e. Remove the charging hose from the 3-way valve service port, then open both the 2-way valve and 3-way valve. (1) (4) (Turn

the valve stem in the counter-clockwise direction until it gently makes contact. Do not turn it forcefully).

f. Tighten the service port cap with a torque wrench (18 N.m (1.8 kgf.m)). (5) Then tighten the 2-way valve and 3-way valve

caps with a torque wrench (42 N.m (4.2 kgf.m)) or (55 N.m (5.5 kgf.m)). (6)

g. After attaching each of the caps, inspect for a gas leak around the cap area. (5) (6)

Panasonic Air Conditioner (CS-E9DKEW) — 11.4. Installation, Transferring, Servicing diagram (page 68)
Fig. 149 · 11.4. Installation, Transferring, Servicing
  • Be sure to read the instructions for the vacuum pump,

vacuum pump adaptor and manifold gauge prior to use, and follow the instructions carefully.

  • Make sure that the vacuum pump is filled with oil up to

the designated line on the oil gauge.

  • The gas pressure back flow prevention valve on the

charging hose is generally open during use. When you are removing the charging hose from the service port, it will come off more easily if you close this valve.

Fig. 12 Vacuum pump air purging configuration

gas leak (4) · Precautions

Page 69 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.4.4. Refrigerant Compatibility (Using R410A Refrigerant in R22 ACs and Vice Versa)
Page 69 · click to enlarge
Page 69

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11.4.2. Transferring (Using New Refrigerant Piping)

1. Removing the unit

a. Collecting the refrigerant into the outdoor unit by pumping down

The refrigerant can be collected into the outdoor unit (pumping down) by pressing the TEST RUN button, even when the temperature of the room is low.

  • Check to make sure that the valve stems of the 2-way valve and 3-way valve have been opened by turning them counter-

clockwise. (Remove the valve stem caps and check to see that the valve stems are fully opened position. Always use a hex wrench (with 4-mm opposing sides) to operate the valve stems.)

  • Press the TEST RUN button on the indoor unit, and allow preliminary operation for 5-6 minutes. (TEST RUN mode)
  • After stopping the operation, let the unit sit for about 3 minutes, then close the 2-way valve by turning the valve stem in

the clockwise direction.

  • Press the TEST RUN button on the indoor unit again, and after 2-3 minutes of operation, turn the valve stem of the 3-

way valve quickly in the clockwise direction to close it, then stop the operation.

  • Tighten the caps of the 2-way valve and 3-way valve to the stipulated torque.
  • Remove the connection pipes (liquid side and gas side).

b. Removing the indoor and outdoor units.

  • Disconnect the pipes and connecting electric cables from between the indoor and outdoor units.
  • Put capped flare nuts onto all of the pipe connections of the indoor and outdoor units, to make sure no dust or other

foreign matter enters.

  • Remove the indoor and outdoor units.
2. Installing the unit

Install the unit using new refrigerant piping. Follow the instructions in section 4.1 to evacuate the pipes connecting the indoor and outdoor units, and the pipes of the indoor unit, and check for gas leaks.

11.4.3. AC Units Replacement (Using Existing Refrigerant Piping)

When replacing an R410A AC unit with another R410A AC unit, you should re-flare the refrigerant piping. Even though the replacement AC unit uses the R410A, problems occur when, for example, either the AC unit maker or the refrigerating machine oil is different. When replacing an R22 AC unit with an R410A AC unit, the following checks and cleaning procedures are necessary but are difficult to do because of the chemical characteristics of the refrigerating machine oil (as described in items c) and d) of section About R410A Refrigerant). In this case, you should use new refrigerant piping rather than the existing piping.

1. Piping check

Because of the different pressure characteristics of R22 and R410A, the design pressure for the equipment is 1.6 times different. the wall thickness of the piping must comply with that shown in Table 10, but this is not easy to check. Also, even if the thickness is correct, there may be flattened or bent portions midway through the piping due to sharp curves. Buried sections of the piping also cannot be checked.

2. Pipe cleaning

A large quantity of refrigerating machine oil (mineral oil) adheres to existing pipes due to the refrigeration cycle circulation. If the pipes are used just as they are for the R410A cycle, the capacity will be lowered due to the incompatibility of this oil with the R410A, or irregularities may occur in the refrigeration cycle. For this reason, the piping must be thoroughly cleaned, but this is difficult with the present technology.

11.4.4. Refrigerant Compatibility (Using R410A Refrigerant in R22 ACs and Vice Versa)

Do not operate an existing R22 AC with the new R410A refrigerant. Doing so would result in improper functioning of the equipment or malfunction, and might lead to a major accident such as an explosion in the refrigeration cycle. Similarly, do not operate an R410A AC with R22 refrigerant. The chemical reaction between the refrigerating machine oil used in R410A ACs and the chlorine that is contained in R22 would cause the refrigerating machine oil to degrade and lead to malfunction.

Page 70 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 70 · click to enlarge
Page 70

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11.4.5. Recharging Refrigerant During Servicing

When recharging is necessary, insert the specified amount of new refrigerant in accordance with the following procedure.

1. Connect the charging hose to the service port of the outdoor unit.
2. Connect the charging hose to the vacuum pump adaptor. At this time, fully open the 2-way valve and 3-way valve.
3. Fully open the handle Lo of the manifold gauge, turn on the power of the vacuum pump and continue the vacuum process for

at least one hour.

4. Confirm that the low pressure gauge shows a reading of -0.1 Mpa (-76 cmHg), then fully close the handle Lo, and turn off the

vacuum pump. Wait for 1-2 minutes, then check to make sure that the needle of the Low pressure gauge has not returned. See Fig. 13 for the remaining steps of this procedure.

5. Set the refrigerant cylinder onto the electronic scale, then connect the hose the cylinder and to the connection port for the

electronic scale. (1)(2)

Precaution:

Be sure to set up the cylinder for liquid charging. If you use a cylinder equipped with a siphon tube, you can charge the liquid without having to turn the cylinder around

6. Remove the charging hose of the manifold gauge from the vacuum pump adaptor, and connect it to the connection port of the

electronic scale. (2)(3)

7. Open the valve of the refrigerant cylinder, then open the charging valve slightly and close it. Next, press the check valve of the

manifold gauge and purge the air. (2)(4) (Watch the liquid refrigerant closely at this point.)

8. After adjusting the electronic scale to zero, open the charging valve, then open the valve Lo of the manifold gauge and charge

with the liquid refrigerant. (2)(5) (Be sure to read the operating instructions for the electronic scale.)

9. If you cannot charge the stipulated amount, operate the unit in the cooling mode while charging a little of the liquid at a time

(about 150 g/time as a guideline). If the charging amount is insufficient from one operation, wait about one minute, then use the same procedure to do the liquid charging again.

Precaution:

Never use the gas side to allow a larger amount of liquid refrigerant to be charged while operating the unit.

10. Close the charging valve, and after charging the liquid refrigerant inside the charging hose, fully close the valve Lo of the

manifold gauge, and stop the operation of the unit. (2)(5)

11. Quickly remove the charging hose from the service port. (6) If you stop midway through, the refrigerant that is in the cycle will

be discharged.

12. After putting on the caps for the service port and operating valve, inspect around the caps for a gas leak. (6)(7)
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 70)
Fig. 150

Fig. 13 Re-charging refrigerant

Page 71 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 11.4.7. Servicing Tips
Page 71 · click to enlarge
Page 71

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

11.4.6. Brazing

As brazing requires sophisticated techniques and experiences, it must be performed by a qualified person. In order to prevent the oxide film from occurring in the pipe interior during brazing, it is effective to proceed with brazing while letting dry nitrogen gas (N2) flow.

<Brazing Method for Preventing Oxidation>

1. Attach a reducing valve to the nitrogen gas cylinder.
2. Apply a seal onto the clearance between the piping and inserted pipe for the nitrogen gas in order to prevent the nitrogen gas

from flowing backward.

3. When the nitrogen gas is flowing, be sure to keep the piping end open.
4. Adjust the flow rate of nitrogen gas so that it is lower than 0.05 m 3 /h, or 0.02 MPa (0.2 kgf/cm 2 ) by means of the reducing valve.
5. After taking the steps above, keep the nitrogen gas flowing until the piping cools down to a certain extent (i.e. temperature at

which pipes are touchable with finger).

6. Completely remove the flux after brazing.
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 71)
Fig. 151

Fig. 14 Prevention of Oxidation during Brazing

1. General Cautions

a. The brazing strength should be high as required.

b. After operation, airtightness should be kept under pressurized condition.

c. During brazing do not allow component materials to become damaged due to overheating.

d. The refrigerant pipe work should not become blocked with scale or flux.

e. The brazed part should not restrict the flow in the refrigerant circuit.

f. No corrosion should occur from the brazed part.

2. Prevention of Overheating

Due to heating, the interior and exterior surfaces of treated metal may oxidize. Especially, when the interior of the refrigerant circuit oxidizes due to overheating, scale occurs and stays in the circuit as dust, thus exerting a fatally adverse effect. So, make brazing at adequate brazing temperature and with minimum of heating area.

3. Overheating Protection

In order to prevent components near the brazed part from overheating damage or quality deterioration due to flame or heat, take adequate steps for protection such as (1) by shielding with a metal plate, (2) by using a wet cloth, and (3) by means of heat absorbent.

4. Movement during Brazing

Eliminate all vibration during brazing to protect brazed joints from cracking and breakage.

5. Oxidation Preventative

In order to improve the brazing efficiency, various types of antioxidant are available on the market. However, the constituents of these are widely varied, and some are anticipated to corrode the piping materials, or adversely affect HFC refrigerant, lubricating oil, etc. Exercise care when using an oxidation preventive.

11.4.7. Servicing Tips

The drier must also be replaced whenever replacing the refrigerant cycle parts. Replacing the refrigerant cycle parts first before replacing the drier. The drier is supplied in a vacuum pack. Perform brazing immediately after opening the vacuum pack, and then start the vacuum within two hours. In addition, the drier also needs to be replaced when the refrigerant has leaked completely. (Applicable for drier models only)

Page 72 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 12.1. Troubleshooting
Page 72 · click to enlarge
Page 72

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

12 Servicing Information

  • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use

a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).

  • Pb free solder will tend to splash when heated too high (about 1100° F/600°C).

12.1. Troubleshooting

1. Rated Frequency Operation

During troubleshooting and servicing, rated compressor operating frequency must be obtained in order to check the specification and technical data. Below are the methods used to obtain rated compressor operating specification.

(i) Press the Auto button continuously for 5 seconds or less than 8 seconds, the air conditioner starts operation at Cooling rated frequency.

(“beep” will be heard at the 5th second.)

Panasonic Air Conditioner (CS-E9DKEW) — 12.1. Troubleshooting diagram (page 72)
Fig. 152 · 12.1. Troubleshooting

(ii) Short the service terminal (CN-S) of the outdoor printed circuit board. The operation of air conditioner is Cooling rated frequency.

Panasonic Air Conditioner (CS-E9DKEW) — 12.1. Troubleshooting diagram (page 72)
Fig. 153 · 12.1. Troubleshooting

Press the Auto button continuously for 8 seconds or less than 11 seconds, the air conditioner starts operation at Heating rated frequency. (“beep” “beep” will be heard at the 8th second.)

(a) Cooling · (b) Heating

Page 73 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 73 · click to enlarge
Page 73

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

2. Troubleshooting Air Conditioner
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 73)
Fig. 154

In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan.

The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 73)
Fig. 155

Refrigeration cycle system

Page 74 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 12.2. Breakdown Self Diagnosis Function
Page 74 · click to enlarge
Page 74

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

1. Relationship between the condition of the air conditioner and pressure and electric current

Cooling Mode Heating Mode Condition of the air

conditoner Low Pressure High Pressure Electric current during operation

Low Pressure High Pressure Electric current during operation

Insufficient refrigerant (gas leakage)

Clogged capillary tube or Strainer

Short circuit in the indoor unit

Heat radiation deficiency of the outdoor unit

  • Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.

12.2. Breakdown Self Diagnosis Function

Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below breakdown diagnosis method:

  • Press “CHECK” button at remote controller continuously for more than five seconds to turn on the diagnosis mode, “H11” will

be displayed at remote controller.

  • By pressing the TMER “

” button once, next error code will be displayed; press “V” button once, previous error code will be displayed.

  • If error code displayed matches the error code saved in unit memory (abnormality detected), “beep, beep, beep....” sounds will

be heard for 4 seconds and Power LED will light on. Otherwise, one “beep” sound is heard.

If “CHECK” button is press again or without any operation for 30 seconds, the diagnosis mode will turn off.

Inefficient compression

Page 75 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 75 · click to enlarge
Page 75

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Abnormality / Protection control Abnormality

Primary location to verify

H11 Indoor / outdoor abnormal communication

> 1 min after starting operation

  • Internal / external cable connections
  • Indoor / Outdoor PCB H12 Connection capability rank abnormal — — — H14 Indoor intake air temperature sensor abnormality

Continue for 5 sec. — • Intake air temperature sensor

(detective or disconnected) H15 Outdoor compressor temperature sensor abnormality

Continue for 5 sec. — • Compressor temperature sensor

(detective or disconnected) H16 Outdoor Current Transformer open circuit

— — • Outdoor PCB

  • IPM (Power transistor) module H19 Indoor fan motor merchanism lock — —
  • Indoor PCB
  • Fan motor H23 Indoor heat exchanger temperature sensor abnormality

Continue for 5 sec. O (Cooling only)

  • Heat exchanger temperature sensor

(defective or disconnected) H26 Ionizer breakdown — — • Ionizer H27 Outdoor air temperature sensor abnormality

Continue for 5 sec. O • Outdoor temperature sensor

(defective or disconnected) H28 Outdoor heat exchanger temperature sensor abnormality

Continue for 5 sec. O • Outdoor heat exchanger

  • temperature sensor (defective or disconnected) H33 Indoor/Outdoor wrong connection — —
  • Indoor/Outdoor supply voltage H38 Indoor / outdoor mismatch (brand code) — — — H98 Indoor high pressure protection — —
  • Air filter dirty
  • Air circulation short circuit H99 Indoor heat exchanger anti-freezing protection

— — • Insufficient refrigerant

  • Air filter dirty F11 Cooling / Heating cycle changeover abnormality

4 times occurance within 30 minutes

— • 4-way valve

  • V-coil F90 PFC control 4 times occurance within 10 minutes

— • Voltage at PFC

F91 Refrigeration cycle abnormality 2 times occurance within 20 minutes

— • No refrigerant

(3-way valve is closed) F93 Compressor rotation failure — — • Compressor F95 Cool high pressure protection 4 times occurance within 20 minutes

— • Outdoor refrigerant circuit

F96 IPM (power transistor) overheating protection

— — • Excess refrigerant

  • Improper heat radiation
  • IPM (Power transistor) F97 Outdoor compressor overheating protection

4 times occurance within 10 minutes

— • Insufficient refrigerant

  • Compressor F98 Total running current protection 3 times occurance within 20 minutes

— • Excess refrigerant

  • Improper heat radiation F99 Outdoor Direct Current (DC) peak detection

7 times occurance continuously

— • Outdoor PCB

  • IPM (Power transistor)
  • Compressor

“O” - Frequency measured and fan speed fixed.

The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard following by pressing the “RESET” button at remote controller.

Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Codes Table) by using remote controller or Auto Switch at indoor unit. However, the remote controller signal receiving sound is changed from one “beep” to four “beep” sounds.

Show 8 more labels / short text on this page
Error Codes Table · Diagnosis · Emergency · display · Judgement · operation · Indoor fan operation · only
Page 76 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 76 · click to enlarge
Page 76

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

12.3. Remote Control

  • Remote Control Reset
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 76)
Fig. 156

When the batteries are inserted for the first time, or the batteries are replaced, all the indications will blink and the remote control might not work.

If this happen, remove the cover of the remote control and push the reset point once to clear the memory data.

  • Changing the wireless remote control transmission
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 76)
Fig. 157

When there are more than one indoor units installed in the same room, it is possible to set different remote control receiving signal by modifying the jumpers inside remote controller.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 76)
Fig. 158

code

Page 77 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 77 · click to enlarge
Page 77

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

12.4. Disassembly of Parts

a. Indoor Control Board Removal Procedures

1. Remove the Front Grille
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 77)
Fig. 159
2. Remove the Indoor Control Board
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 77)
Fig. 160
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 77)
Fig. 161
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 77)
Fig. 162
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 77)
Fig. 163
Page 78 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 78 · click to enlarge
Page 78

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

b. Electronic Controller Removal Procedures

1. Remove Main Electronic Controller
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 78)
Fig. 164
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 78)
Fig. 165

c. Cross Flow Fan and Fan Motor Removal Procedures

1. Remove Cross Flow Fan and Fan Motor
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 78)
Fig. 166
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 78)
Fig. 167
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 78)
Fig. 168
Page 79 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 79 · click to enlarge
Page 79

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

d. Outdoor Electronic Controller Removal Procedure

  • Be save to return the wiring to its original position
1. Remove the top panel and front panel
  • There are many high voltage components within the heat
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 79)
Fig. 169

sink cover so never touch the interior during operation. Wait at least two minutes after power has been turned off.

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 79)
Fig. 170
2. Remove the Outdoor Electronic Controller
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 79)
Fig. 171
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 79)
Fig. 172
Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 79)
Fig. 173
Page 80 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 80 · click to enlarge
Page 80

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

13 Technical Data

13.1. Operation Characteristics

13.1.1. CS-E9DKEW CU-E9DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 80)
Fig. 174
Page 81 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 81 · click to enlarge
Page 81

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

13.1.2. CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 81)
Fig. 175
Page 82 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 82 · click to enlarge
Page 82
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 82)
Fig. 176 · 8 Operation Details

30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0°C 2.58 1.96 0.55 2.41 1.88 0.59 2.24 1.80 0.63 2.04 1.71 0.68 19.0°C 2.60 0.60 19.5°C 2.83 2.05 0.56 2.65 1.97 0.60 2.46 1.89 0.64 2.24 1.80 0.69 22.0°C 3.09 2.12 0.57 2.88 2.04 0.61 2.68 1.97 0.66 2.44 1.88 0.71

30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0°C 3.47 2.63 0.88 3.24 2.52 0.95 3.02 2.43 1.02 2.74 2.30 1.10 19.0°C 3.50 0.97 19.5°C 3.81 2.76 0.90 3.56 2.65 0.97 3.31 2.55 1.04 3.01 2.43 1.12 22.0°C 4.15 2.86 0.92 3.88 2.75 0.99 3.61 2.65 1.05 3.28 2.53 1.14

Page 83 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 83 · click to enlarge
Page 83

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

14 Exploded View (Indoor Unit)

14.1. CS-E9DKEW CS-E12DKEW

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 83)
Fig. 177

The above exploded view is for the purpose of parts disassembly and replacement.

The non-numbered parts are not kept as standard service parts.

Page 84 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 84 · click to enlarge
Page 84

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

15 Replacement Parts List (Indoor Unit)

15.1. CS-E9DKEW CS-E12DKEW

REF. NO. PART NAME & DESCRIPTION QTY. CS-E9DKEW CS-E12DKEW REMARKS 1 CHASSY COMPLETE 1 CWD50C1431 ← 2 FAN MOTOR 1 CWA981149 ← 0 3 CROSS FLOW FAN COMPLETE 1 CWH02C1031 ← 4 BEARING ASS’Y 1 CWH64K007 ← 5 SCREW - CROSS FLOW FAN 1 CWH4580304 ← 6 EVAPORATOR 1 CWB30C1597 CWB30C1726 7 FLARE NUT 1 CWT25086 (1/4”) ← 8 FLARE NUT 1 CWT25087 (3/8”) CWT25096 (1/2”) 9 HOLDER SENSOR 1 CWH32143 ← 10 DISCHARGE GRILLE COMPLETE 1 CWE20C2343 ← 11 VERTICAL VANE 9 CWE241150 ← 12 CONNECTING BAR 1 CWE261072 ← 13 CONNECTING BAR 1 CWE261065 ← 14 AIR SWING MOTOR 2 CWA98260 ← 0 15 LEAD WIRE - AIR SWING MOTOR 1 CWA67C3849 ← 16 CAP - DRAIN TRAY 1 CWH521096 ← 17 HORIZONTAL VANE 1 CWE241173 ← 18 BACK COVER CHASSIS 1 CWD932454 ← 19 CONTROL BOARD CASING 1 CWH102259 ← 20 TERMINAL BOARD COMPLETE 1 CWA28C2082 ← 0 21 POWER SUPPLY CORD 1 - - 22 ELECTRONIC CONTROLLER - MAIN 1 CWA73C1667 CWA73C1668 0 23 LEAD WIRE - AIR SWING MOTOR 1 CWA67C3977 ← 0 24 SENSOR COMPLETE 1 CWA50C2122 ← 0 25 CONTROL BOARD FRONT COVER 1 CWH13C1120 ← 26 INDICATOR COMPLETE 1 CWE39C1126 ← 0 27 INDICATOR HOLDER 1 CWD932429 ← 28 INDICATOR HOLDER 1 CWD932430 ← 29 CONTROL BOARD TOP COVER 1 CWH131207 ← 30 REMOTE CONTROL COMPLETE 1 CWA75C2616 ← 0 31 FRONT GRILLE COMPLETE 1 CWE11C3138 ← 0 32 INTAKE GRILLE 1 CWE22C1154 ← 33 GRILLE DOOR 1 CWE141073 ← 34 AIR FILTER 2 CWD001144 ← 35 SCREW - FRONT GRILLE 2 XTT4+16C ← 36 CAP - FRONT GRILLE 2 CWH521109 ← 37 DRAIN HOSE 1 CWH851063 ← 38 INSTALLATION PLATE 1 CWH361067 ← 39 BAG COMPLETE - INSTALLATION SCREW 1 CWH82C067 ← 40 FULCRUM 1 CWH621046 ← 41 ELECTRONIC CONTROLLER - IONIZER 1 CWA743675 ← 0 42 CASING - IONIZER 1 CWD932464 ← 43 CASING - IONIZER 1 CWD932431 ← 44 ION GENERATOR 1 CWH94C0001 ← 45 SUPERSONIC AIR PURIFYING DEVICE 1 CWH91C1013 ← 46 ELECTRONIC CONTROLLER SUPERSONIC 1 CWA743874 ← 0 47 SUPER ALLERU BUSTER FILTER 1 CWD00C1133 ← 48 FRAME FR AIR FILTER SUPERSONIC 1 CWD011026 ← 49 FRAME FR AIR FILTER SUPERSONIC 1 CWD011027 ←

  • All parts are supplied from PHAAM, Malaysia (Vendor Code: 061).
  • “O” marked parts are recommended to be kept in stock.

(Note)

Page 85 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 85 · click to enlarge
Page 85

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

16 Exploded View (Outdoor Unit)

16.1. CU-E9DKE CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 85)
Fig. 178

The above exploded view is for the purpose of parts disassembly and replacement.

The non-numbered parts are not kept as standard service parts.

Page 86 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 1 CWF564451 ←
Page 86 · click to enlarge
Page 86

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

17 Replacement Parts List (Outdoor Unit)

17.1. CU-E9DKE CU-E12DKE

REF NO. DESCRIPTION & NAME QTY. CU-E9DKE CU-E12DKE REMARKS 1 CHASSY ASSY 1 CWD50K2073 ← 2 ANTI-VIBRATION BUSHING 3 CWH50077 ← 3 COMPRESSOR 1 5RS102XBC01 ← O 4 NUT-COMPRESSOR MOUNT 3 CWH56000 ← 5 SOUND PROOF MATERIAL 1 CWG302293 ← 6 FAN MOTOR BRACKET 1 CWD541030 ← 7 FAN MOTOR 1 CWA951418 CWA951309 O 8 SCREW - FAN MOTOR BRACKET 2 CWH551060 ← 9 SCREW - FAN MOTOR MOUNT 4 CWH55406 ← 10 PROPELLER FAN ASSY 1 CWH03K1006 ← 11 NUT - PROPELLER FAN 1 CWH56053 ← 12 CONDENSER 1 CWB32C1560 CWB32C1599 13 TUBE ASS’Y CO (CAP./CHK VALVE) 1 CWT01C3257 CWT01C3258 14 HOLDER-COUPLING COMPLETE 1 CWH351023 ← 15 3 WAYS VALVE 1 CWB011296 CWB011297 O 16 4 WAYS VALVE 1 CWB001037 ← O 17 SOUND PROOF MATERIAL 1 CWG302292 ← 18 2 WAYS VALVE 1 CWB021255 ← O 19 DRYER 1 CWB101017 ← O 20 V-COIL COMPLETE 1 CWA43C2143 ← O 21 REACTOR 1 CWA421050 - 22 SENSOR COMPLETE 1 CWA50C2196 ← 23 CONTROL BOARD CASING 1 CWH102273 ← 24 TERMINAL BOARD ASSY 1 CWA28K1110 ← 25 FUSE HOLDERS 1 K5D203BBA002 ← 26 CONTROL BOARD 1 CWH102114 ← 27 CONTROL BOARD 1 CWH102115 ← 28 ELECTRONIC CONTROLLER 1 CWA73C1672R CWA73C1673R O 29 CONTROL BOARD COVER 1 CWH131104 ← 30 SENSOR COMPLETE 1 CWA50C2066 ← 31 HOLDER SENSOR 1 CWH321010 ← 32 TERMINAL COVER 1 CWH171001 ← 33 NUT-TERMINAL COVER 1 CWH7080300 ← 34 CABINET SIDE PLATE CO. 1 CWE04C1011 ← 35 CABINET SIDE PLATE (LEFT) 1 CWE041031A ← 36 HANDLE 1 CWE161010 ← 37 WIRE NET 1 CWD041054A ← 38 CABINET FRONT PLATE CO. 1 CWE06C1039 ← 39 CABINET TOP PLATE 1 CWE031014A ← 40 CONTROL BOARD COVER 1 CWH131110 ← 41 CONTROL BOARD COVER 1 CWH131093 ← 42 OPERATING INSTRUCTION (ENG., ESP., ITA., NED., POR., GRE., BUL.)

1 CWF564451 ←

43 INSTALLATION INSTRUCTION (ENG., ESP., FRA., DEU.) 1 CWF612674 ← 44 L-TUBE 1 CWH5850080 ← 45 INSTALLATION INSTRUCTION (NED., GRE., ITA., POR.) 1 CWF612675 ← 46 INSTALLATION INSTRUCTION (BUL.) 1 CWF612676 ← 47 OPERATING INSTRUCTION (FRA., DEU., SWE., NOR.) 1 CWF564445 ← 48 PACKING-L.TUBE 1 CWB81012 ← 49 SOUND PROOF BOARD 1 CWH151025 ←

  • All parts are supplied from PHAAM Malaysia (Vendor Code: 061).
  • “O” marked parts are recommended to be kept in stock.

(Note)

Page 87 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 87 · click to enlarge
Page 87
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 87)
Fig. 179 · 8 Operation Details

C32 100µ 25V R69 6.2kΩ 1/4W R70 6.2kΩ 1/4W

Page 88 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 88 · click to enlarge
Page 88
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 88)
Fig. 180 · 8 Operation Details

R33 10kΩ R34 10kΩ R35 10kΩ

Page 89 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 89 · click to enlarge
Page 89
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 89)
Fig. 181 · 8 Operation Details

72 73 74 75 76 77 78 79 80

21 22 23 24 25 26 27 28 29

1µ C14 0.01µ C15 0.01µ C09

Page 90 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 90 · click to enlarge
Page 90
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 90)
Fig. 182 · 8 Operation Details
Page 91 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 91 · click to enlarge
Page 91
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 91)
Fig. 183 · 8 Operation Details
Page 92 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 92 · click to enlarge
Page 92
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 92)
Fig. 184 · 8 Operation Details

92 93 94 95 96 97 98 99 100

31 32 33 34 35 36 37 38 39

Page 93 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — 8 Operation Details
Page 93 · click to enlarge
Page 93
Panasonic Air Conditioner (CS-E9DKEW) — 8 Operation Details diagram (page 93)
Fig. 185 · 8 Operation Details

R86 510Ω 1/4W R87 10k R91 33Ω 1/4W

Page 94 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 94 · click to enlarge
Page 94

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 94)
Fig. 186
Page 95 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 95 · click to enlarge
Page 95

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

How to use electronic circuit diagram

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 95)
Fig. 187
Page 96 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 96 · click to enlarge
Page 96

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

18.3. Remote Control

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 96)
Fig. 188
Page 97 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 97 · click to enlarge
Page 97

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

18.4. Print Pattern Indoor Unit Printed Circuit Board

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 97)
Fig. 189
Page 98 of the Panasonic Air Conditioner (CS-E9DKEW) user manual — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE
Page 98 · click to enlarge
Page 98

CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE

18.5. Print Pattern Outdoor Unit Printed Circuit Board

Panasonic Air Conditioner (CS-E9DKEW) — CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE diagram (page 98)
Fig. 190

[PHAAM] Printed in Malaysia

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Panasonic Air Conditioner (CS-E9DKEW)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic Air Conditioner (CS-E9DKEW)

Be the first to ask — other owners or our team will answer.

Original document

Panasonic Air Conditioner (CS-E9DKEW) manual PDF

98 pages·9.2 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…