11 Installation And Servicing Air Conditioner Using R410A 61
© 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.


18.4. Print Pattern Indoor Unit Printed Circuit Board 97
18.5. Print Pattern Outdoor Unit Printed Circuit Board 98
− Automatic air swing and manual adjusted by Remote
Inactive various harmful airbone elements including allergens, viruses and bacteria.
Generated supersonic waves enhance the ability to collect dust and dirt in the air.


2.1. Remote Control

Indoor Fan Speed Selection FAN SPEED
Operation OFF / ON
MODE
TEMP Operation Mode Selection
ON
OFF
Powerful Mode Operation
Quiet Mode Operation OFF / ON QUIET
Ion Mode Operation OFF / ON
CANCEL
Timer Operation Set / Cancel
AIR SWING
CLOCK
Clock Setting
Check Point
∧ ∨ · Reset Point RESET

2.2. Indoor Unit

Four Operation Modes
Automatic and 5 Manual Vertical Airflow Directions
Automatic and 5 Manual Horizontal Airflow Directions
Powerful Mode
Operation Indication Lamps (LED)
operation, blinks in Automatic Operation Mode judging and Hot Start operation. • TIMER (Orange) Lights up in Timer
Setting. Blinks in Self Diagnosis Control. • QUIET (Orange) Lights up in Quiet
Mode Operation. • SUPER ALLERU-BUSTER (Blue) ... Lights up in
operation.

Breakdown Self Diagnosis Function
Low Pressure Control (Gas Leakeage Detection)
Indoor Power Relay Control
Deodorizing Control
Anti-Dew Formation Control
Anti Freezing Control
Anti-Cold Draft Control
Hot Start
Intake Air Temperature Control
High Pressure Control
Deice Operation

2.3. Outdoor Unit
Time Delay Safety Control
30 seconds Forced Operation
Overload Protection Control
Total Running Current Control
Compressor Overheating Prevention Control
IPM (Power Transistor) Overheating Protection Control
Low Operation Frequency Protection Control
Mininum Operation Frequency Protection Control
Outdoor Air Temperature Control
Standby Control
Deice Operation

3 Product Specifications
3.1. CS-E9DKEW CU-E9DKE
Cooling Capacity kW kcal/h BTU/h
2.6 (0.80 - 3.00) 2,240 (690 - 2,580) 8,870 (2,050 - 10,200)
Heating Capacity kW kcal/h BTU/h
3.6 (0.80 - 5.00) 3,100 (690 - 4,300) 12,300 (2,050 - 17,100)
Moisture Removal l/h Pint/h
1.6 (3.4)
Power Source (Phase, Voltage, Cycle) ø V Hz
TOP VIEW


Air Volume Lo m3/min (cfm) Cooling; 6.2 (220) — Heating; 6.6 (230) Me m3/min (cfm) Cooling; 7.9 (280) — Heating; 8.6 (300) Hi m3/min (cfm) Cooling; 9.6 (340) Cooling; 29.8 (1,050) Heating; 10.5 (370) SHi m3/min (cfm) Cooling; 9.9 (350) — Heating; 10.8 (380)
dB (A) Cooling; High 39, Low 26 Cooling; 46 Heating; High 40, Low 27 Heating; 47 Noise Level
Power level dB Cooling; High 50 Cooling; High 59 Heating; High 51 Heating; High 60
Electrical Data Input W Cooling; 600 (175 - 780) Heating; 845 (165 - 1,360)
Running Current A Cooling; 2.9 Heating; 4.0
EER W/W (kcal/hw), BTU/hw Cooling; 4.33 (3.73), 14.8 COP W/W (kcal/hw), BTU/hw Heating; 4.26 (3.67), 14.6 Starting Current A 4.0 Piping Connection Port (Flare piping)
G ; Half Union 3/8”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4” Pipe Size (Flare piping)
L ; Half Union 1/4”
G (gas side) ; 3/8” L (liquid side) ; 1/4” Drain Hose
G (gas side) ; 3/8” L (liquid side) ; 1/4”
Inner diameter mm 12 — Length m 0.65 —


3.2. CS-E12DKEW CU-E12DKE
Cooling Capacity kW kcal/h BTU/h
3.50 (0.80 - 4.00) 3,010 (690 - 3,440) 11,950 (2,730 - 13,600)
Heating Capacity kW kcal/h BTU/h
4.80 (0.80 - 6.50) 4,130 (690 - 5,590) 16,400 (2,730 - 22,200)
Moisture Removal l/h Pint/h
2.0 (4.2)
Power Source (Phase, Voltage, Cycle) ø V Hz
TOP VIEW
INTAKE
Air Volume Lo m3/min (cfm) Cooling; 6.9 (240) — Heating; 8.1 (290) Me m3/min (cfm) Cooling; 8.8 (310) — Heating; 9.7 (340) Hi m3/min (cfm) Cooling; 10.7 (380) Cooling; 31.0 (1,090) Heating; 11.2 (400) SHi m3/min (cfm) Cooling; 11.0 (390) — Heating; 11.6 (410)
dB (A) Cooling; High 42, Low 29 Cooling; 48 Heating; High 42, Low 33 Heating; 50 Noise Level
Power level dB Cooling; High 53 Cooling; High 61 Heating; High 53 Heating; High 63
Electrical Data Input W Cooling; 965 (185 - 1,200) Heating; 1,260 (175 - 1,890)
Running Current A Cooling; 4.5 Heating; 5.8
EER W/W (kcal/hw), BTU/hw Cooling; 3.63 (3.12), 12.4 COP W/W (kcal/hw), BTU/hw Heating; 3.81 (3.28), 13.0 Starting Current A 5.8 Piping Connection Port (Flare piping)
G ; Half Union 1/2”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4” Pipe Size (Flare piping)
L ; Half Union 1/4”
G (gas side) ; 1/2” L (liquid side) ; 1/4” Drain Hose
G (gas side) ; 1/2” L (liquid side) ; 1/4”
Inner diameter mm 12 — Length m 0.65 — Power Cord Length Number of core-wire


4 Dimensions
4.1. Indoor Unit & Remote Control
4.1.1. CS-E9DKEW CS-E12DKEW


4.2. Outdoor Unit
4.2.1. CU-E9DKE CU-E12DKE


5 Refrigeration Cycle Diagram


6 Block Diagram


7 Wiring Diagram


8 Operation Details
8.1. Basic Function
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air temperature.
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes. These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.

30 +1.0 Heating 9
9 -0.5 1
1 +1.0
20 0.0 Soft Dry X
20 0.0 Heating X
20 +3.5

value.
Actual operation mode Target room temperature offset value (dGetaDst) Cooling (1) Heating (2) Dry (0)
i) Initial value when operation starts, or changing the actual operation mode.
Set the offset value at each operation mode. However, in order to improve the heating start up efficiency, the offset value will be changed based on the gap between setting temperature and room temperature.
Actual operation mode Gap between setting temperature and room
Room temperature offset value
(dGeta) Cool — (0) Heat (Operation start set temp. - room temp)
4°C (4) Dry — (0)
ii) Updating during operation
During operation, it will compare with the target room temperature offset value at specific period, then the room temperature will be updated.
Actual operation mode Room temperature zone Updating period (sec.) Cool — (180) Heat A, B, C, D zone (15) Dry — (180)
Update the room temperature offset value (dGeta)
Temperature condition Room temp. offset value after modified (dGeta) Target room temp. offset value > Room temp. offset value
dGeta + (0.5)
Target room temp. offset value < Room temp. offset value
dGeta - (0.5)
Target room temp. offset value = Room temp. offset value
However, if the following condition is occurred, temperature cannot detect correctly and therefore no updating will be done.
Comp starting *within 600 sec.

8.1.2. Compressor Operation Frequency
8.1.2.1. The frequency determination method (Cooling operation control)
8.1.2.1.1. Basic specification
The domain directions data (intake-setting) transmitted from the interior of a room determines a changed part of frequency.
Then, a directed changed part changes frequency to the present frequency.
After a starting control end, initial frequency (absolute value) is determined.
However, a FcMAX domain judges instantly.

When (Suction-setup) is +0.5deg, directions of Fcmax came by the mentioned initial frequency.
Fcmax continued until it reaches. (If other directions came by protection control, priority is given)
When room temperature is reached, it shifts to relative control after moving to change frequency.
The following operation determines change frequency.
The Hzkirikae = present condition frequency * Inclines and it is calculation.
Inclination = lapsed time to remote control attaintment (Minute)
Inclination 0 - 60 60 - 90 90 Inclination coefficient 80% 90% 100%
The time to room temperature attainment is calculated.
With initial frequency, it is considered as change frequency.

8.1.2.1.4. The frequency changed method
changes relatively to present condition.
has the following renewal of data, an addition and subtraction tap is switched.
of initial frequency and operation frequency is determined.

8.1.2.2.1. Basic specification
Intake temperature domain is sent to outdoor. Renewal of data every 60 seconds in outdoor.
Domain directions data (intake-setting) transmitted from indoor determine a changed part of frequency.
Then, a directed changed part changes frequency to the present frequency.
Change of frequency may be 1 tap = 1Hz.

8.1.2.2.2. Initial frequency determination
After a starting control end, initial frequency (absolute value) is determined and is immediately shift.
However, the domain of Fhmax is judged instantly.

When directions of Fhmax determined from mentioned initial frequency, (intake-setting) relativity control. Fhmax continued until (If other directions came by protection control, priority is given there) room temperature is reached, it shifts to relative control after moving to change frequency.
The following operation determines change frequency.
The Hzkirikae = present condition frequency *Inclines (calculation)
Inclination = Lapsed time to remote control attainment (min)
Inclination 0 - 30 30 - 60 60 Inclination coefficient 70% 90% 100%
The time to room temperature attainment is calculated.
With initial frequency, it is considered as change frequency.

8.1.2.2.4. The frequency changed method
domain and frequency changes relatively to the present condition.
When it moves, addition or subtraction tap is changed at the time of the following renewal of data.
to the clause of initial frequency and operation frequency is determined.

8.1.2.3.1. Basic specification
The domain directions data (intake-setting) transmitted from indoor determines a changed part of frequency.
Then, a directed changed part changes frequency to the present frequency.
Change of frequency may be 1 tap = 1Hz.
It applies to cooling correspondingly.
It shifts to initial frequency after a starting frequency end.
22°C ID intake < 22°C Frequency ESCHZ02 ESCHZ01 38 (E12), 31 (E9) 34 (E12), 28 (E9)
ID intake

8.1.2.3.3. The frequency change method
domain and frequency changes relatively to the present condition.
an addition-and-subtraction tap is changed from the time of the following renewal of data.

8.1.3.1. Thermostat control
point.


8.1.4. Soft Dry Operation
8.1.4.1. Thermostat control
point.

8.1.5.1. Thermostat control
point.

This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air temperature and outdoor air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to detect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.


Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2 and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on the above operation mode chart, every 30 minutes.
Remote Control Setting Temperature (°C) T1 T2 T3 16 ~ 18 +10 -3 -5 19 ~ 22 +8 -3 -7 23 ~ 26 +7 -3 -7 27 ~ 30 +6 -3 -8
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice verse.
Operation Mode change from Temperature shifts (°C) Cooling/Soft Dry →Heating -2 Heating →Cooling/Soft Dry +2
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 - 3 = 22; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on indoor intake air temperature and outdoor air temperature at the time when the judgment is made.

A. Basic Rotation Speed (rpm)
Remote Control — — O — — — Tab (rpm) PSHI SHI Hi Me+ Me Me- Lo Lo- SLo SSLo E9DK 1320 1320 1280 1165 1050 935 820 760 720 710 E12DK 1460 1460 1420 1293 1165 1038 910 840 720 710
Remote Control — — O — — — Tab (rpm) PSHi SSHi SHi Me+ Me Me- Lo Lo- SLo SSLo E9DK 1440 1440 1400 1270 1140 1010 880 820 720 710 E12DK 1540 1540 1500 1395 1290 1185 1080 1010 720 710
[Cooling, Dry, Fan] · [Heating]

B. Indoor Fan Control
i. Indoor fan control operation outline



ii. Auto Fan Speed



a. UP:
b. DOWN:
c. Current Output Fixed:
d. Instantaneous Maximum:
e. Temperature in ( ) is for Powerful Mode operation.
C. Fan Motor Control
High voltage PWM Motor
a. Number-of-rotations feedback
Immediately after the fan started, rpm is checked and duty is added, and feedback control is performed. For high voltage PWM motor, it is done once every 0.5 second.
b. Offset duty T max/min limit
High voltage PWM motor has maximum offset duty.
(Refer Indoor fan motor control basic rotation speed)
Conditions:
a. Out of rhythm signal input
b. If feedback number of rotations exceeded #2550 r/min or when less than #50 r/min.
* It will not detect the out of rhythm condition within 5s for phase control motor (PWM motor is when duty=0) after start.
A fan stops when condition (1) and (2) happen within 25.0 seconds after fan starting, and if this happens for continuously 7 times, it will not retry.
→FM lock processing
Restart is prohibited within 5s for phase control motor (PWM motor is when duty=0) after fan stop (except re-ON the power supply).

D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON 1 →2 →3 (Shift to 4 when COMP is OFF) * When COMP is OFF 4 →5 →6 →7 →6 ←→7 (Shift to 1 when COMP is ON) * Start from 4 if the Thermostat is OFF during the start operation.
Odor Status 1 2 3 4 5 6 7 6.7.6... 1 Status Shift according to COMP
zone 40 50 — 30 90 20 90 20.90.20... to time (s) Dry zone ON
SSLo OFF SSLo OFF SSLo.OFF... Dry zone SLo

Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after compressor stops operation.

and intake air temperature) and manual (angles of direction can be adjusted using remote control).

8.1.9.1. Vertical Airflow
Operation Mode Airflow Direction Vane Angle (°) 1 2 3 4 5 Heating Auto with Heat Exchanger A Upward fix 3 Temperature B Downward fix 64 C Upward fix 3 D Downward fix 3 Manual 3 17 33 49 63 Cooling, Soft Dry and Ion Auto 8 ~ 36 Manual 8 15 22 30 36 Mode Judgment in Auto Auto 8 Manual 8 15 22 30 36
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane will shift to close position.
of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position.

below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below.
Operation Mode Vane Angle (°) Heating, with heat exchanger temperature A 65 ~ 115 B 90 Cooling, Soft Dry and Ion 65 ~ 115

of the vane are as Figure 2 above.
Pattern 1 2 3 4 5 Airflow Direction Patterns at Remote Control
Vane Angle (°) 90 65 78 102 115

8.1.10. Quiet operation (Cooling Mode/Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
Quiet LED illuminates.
b. Quiet operation stop condition
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.
C. Control contents
This is to reduce sound of Hi, Me, Lo for 3dB.
A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
Quiet LED illuminates.
b. Quiet operation stop condition
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.

C. Control contents
a. Fan Speed manual
This is to reduce sound of Hi, Me, Lo for 3dB.
Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature quickly.

(b) Soft Dry Operation


Delay ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
(a) Cooling Operation · (c) Heating Operation


Delay OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes.

BUSTER Color Green Orange Orange Orange Green Blue Light ON Operation ON Timer Setting ON Quiet Mode ON Powerful Mode ON Ion Mode ON Operation ON Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF Ion Mode OFF Operation OFF
judgment, or delay ON timer sampling.


button for 5s for the unit to operate in Heating Mode.
for 5s), the unit can be changed to different controlling setting (4 type of transmission codes).
receiving sound can be cancelled or turned on.
To provide fresh air effect to users by discharging minus ion to air.

a. Ionizer Only Operation.
Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1 →2)
However, fan speed can be adjusted later by customer during this operation.

Airflow direction (Horizontal Vane) control:
Follow vane direction control at cooling mode.
Horizontal vane can be changed by customer during ion only operation.
b. Operation Mode + Ionizer Operation.
When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Auto mode) and ION operation button at remote control is pressed. Ionizer on & ION LED illuminates. (3 →4)
Power LED also illuminates.
Purpose · Control Condition

When one of the following condition is satisfied, ION operation stops.
a. Stopped by ON/OFF switch.
b. Timer OFF activates.
c. ION feedback signal shows error.
without ionizer operation.
c. Timer during ionizer operation
Refer to case study in next page for detail.
i. Purpose
To inform user of ionizer problems and detection.
ii. Two types of problem detection control:
Control Detection Method Protection Recovery
(i) Actual ion is permanently OFF & ion
(i) Press ON/OFF button
30 min. continuously for 24 times (approx. 11 hr. 30 min.)
LED is blinking.
(ii) ion feedback signal:
0V (ii) Within 24 counts, if anytime
(ii) Press remote control ion button for
CONDITION becomes false then count is cleared.
a) ON: Ion LED blink & buzzer = beep b) OFF: Ion LED OFF & buzzer = beep
Off by force operation
Case 1: During Air-Con. ON. Air-Cond OFF with abnormal no. H26 is activated with timer LED is blinking permanently.
(i) Actual ion OFF
CONDITION becomes false.
Case 2: During Air-Con. OFF. Abnormal no. H26 is activated with timer LED is blinking permanently for both cases 1 & 2.
(ii) Once recovered, ion &
Timer LED stops blinking permanently. (ii) Press remote control ion button for
(iii) Main power reset.
(iii) Press any remote control button to


8.2. Protection Control Features
8.2.1. Protection Control For All Operations
8.2.1.1. Time Delay Safety Control
decreased.
Model E9DK E12DK Operation Mode X (A) Y (A) X (A) Y (A) Cooling/Soft Dry (A) 4.0 16.8 5.4 16.8 Cooling/Soft Dry (B) 3.6 16.8 5.0 16.8 Heating 5.5 16.8 8.4 16.8


8.2.1.4. IPM (Power transistor) Prevention Control
A. Overheating Prevention Control
B. DC Peak Current Control
three minutes.
minute.
If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off.
Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The changes of frequency are as below figure.

a. Control start conditions
Control will perform when (1) - (3) condition continues operation for 5 minute and (4) is fulfill.
Ic = Ia = 1.65 A
Ib = 0.65 A
During of heating operation: Indoor piping temperature-indoor suction is under 5°C.
Control contents:
Ia

8.2.1.7. Compressor Tank Temperature Rise Protection Control
a. Control start conditions
Control will perform when (1) - (3) condition continues operation for 5 minute and (4) is fulfill.
Remote control Hi; 16 degrees C
Remote control Hi; 30 degrees C
It is not during deice operation
During heating operation: Indoor piping temperature-indoor suction is under 5°C.
Control contents:
When the compressor operate at frequency lower than 22 Hz continued for 20 minutes, the operation frequency will be increased to 22 Hz for two minutes.
When all the below conditions occur, minimum value (Freq. MIN) for the frequency instructed to compressor will change to 30 Hz for cooling mode operation and 20 Hz for heating mode operation.
30 — Outdoor air (°C) T
24 Indoor heat exchanger (°C) T
30 T
8.2.1.10. Minimum Frequency Protection Control
Indoor Fan Speed min Hz More than Hi 29 More than Me- 27 Less than Me- 27 Automatic 27
However, when less than thermo OFF for 120 sec. continuously, the above control will be cancel.
15 or T · 16 or T · 4 or T

Indoor Fan Speed Min Hz More than Hi 27 More than Lo 27 Under Lo 27
However, when less than thermo OFF for 100 sec. continuously, the above control will be cancel.
In order to control DC current rise in a compressor low frequency region, load is detected with from indoor/outdoor heat exchanger temperature, Hz control is performed.

(However, official approval mode removes)

8.2.2.1. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below.
This control will begin one minute after the compressor starts.

Purpose · Control contents

8.2.2.2. Cooling Overload Control
i. Pipe temperature limitation/restriction

ii. Electrical part temperature rise protection control
To prevent electronic components temperature rise during cooling overload.

- Change a current limit value in a protection location A. (Refer to the clause of total running current control value)
It is canceled when it stops satisfying all of the above-mentioned.
Outdoor temperature

8.2.2.3. Anti-Freezing Control

fog discharged from indoor as shown in below table.
rpm Operation time, T (min) E9DK E12DK 0
30 26 Hz 39 Hz Below 710 30
90 26 Hz 37 Hz 90
420 26 Hz 37 Hz 0
30 40 Hz 59 Hz 710 ~ 790 30
90 33 Hz 48 Hz 90
420 32 Hz 47 Hz 0
30 50 Hz 70 Hz 791 ~ 970 30
90 40 Hz 59 Hz 90
420 40 Hz 59 Hz 0
30 52 Hz 72 Hz 970 above 30
90 40 Hz 59 Hz 90
T
420 40 Hz 59 Hz
8.2.3.1. Intake Air Temperature Control
Compressor will operate at Max freq 67 Hz if either one of the below conditions occur:

8.2.3.2. Outdoor Air Temperature Control
The Max current value is regulated in accordance to the outdoor air temperature as shown in the below figures.

The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown in below figures.


8.2.3.4. Deice Control
A. Deice operation (Normal Deice Operation)
Outdoor heat exchanger temperature sensor, timer.

which is first fulfilled and shift to the next mode.

Outdoor heat exchanger temperature
a 15°C b 18°C c 25°C
(Instantaneous, restart)

When any of below a, b, c, d condition is satisfied, deice signal is produced.
a. Continuously, outdoor heat exchanger temperature < 3°C for 120 minutes and outdoor heat exchanger temperature
< -6°C for 3 minutes and outdoor air temperature > -1°C and Comp. is ON.
b. Continuously, outdoor heat exchanger temperature < 3°C for 80 minutes and outdoor heat exchanger temperature
< -7°C for 3 minutes and outdoor air temperature > -1°C and Comp. is ON.
c. Continuously, outdoor heat exchanger temperature < 3°C for 40 minutes and outdoor heat exchanger temperature
< -9°C for 3 minutes and outdoor air temperature
-3°C and Comp. is ON.
d. Continuously, outdoor heat exchanger temperature < 3°C for 40 minutes and outdoor heat exchanger temperature
< -11°C for 3 minutes and outdoor air temperature < -3°C and Comp. is ON.
However, the first deice will start only after minimum of 60 minutes in operation.
(2nd deice and onward shall follow above conditions)

9 Operating Instructions


Thank you for purchasing Panasonic Air Conditioner

To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classifi ed as below:
Do not install, remove and reinstall the unit by yourself. • Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
This sign warns of death
or serious injury.
This sign warns of injury
or damage to property.
The instructions to be followed are classifi ed by the following symbols:
an action that is
PROHIBITED.
actions that are COMPULSORY.


Operation Condition (OC)
Use this air conditioner under the following temperature range.
The appliance is not intended for use by young children or infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Maximum Temperature (COOL) 32 23 43 26
Maximum Temperature (HEAT) 30 – 24 18
Minimum Temperature (COOL) 16 11 16 11
Minimum Temperature (HEAT) 16 – -5 -6




Supersonic air purifying device








Do not touch during operation

Press until “beep” sound and release.
Press until “beep” sound and release.
Press again until “beep-beep” sound
Memory reset Clock setting
and release.

G Operation delayed for few minutes after restart. ➤ This is a normal self protection control.
G Sound like water fl owing during operation. ➤ Caused by refrigerant fl ow inside.
G Mist emerges from indoor unit. ➤ Condensation effect due to cooling process.
G Noisy during operations. ➤ Installation work could be slanted or front panel didn’t close properly.
G Remote control/display does not work. ➤ Check whether batteries are correctly inserted or need replacement.
G The unit cannot operate. ➤ Check either circuit breaker is tripped or timer is used correctly.
G Outdoor unit emits water/steam. ➤ Condensation or evaporation happens at piping surface.



AUTO - Automatic Operation

HEAT - Heating Operation

Start the operation.


Select the desired operation.

COOL - Cooling Operation
HEAT DRY
COOL
DRY - Soft Dry Operation
G Supersonic air purifying device (super alleru-buster) operates
automatically while the air conditioner is switched on.
G Powerful, Quiet and Ion operations could be activated in all
operation modes.
button again to stop the operation.

G To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.

G The room has a peculiar odour. ➤ This may be a damp smell emitted by the wall, carpet, furniture or
clothing in the room.
G Air conditioner does not cool or heat effi ciently. ➤ Ensure the temperature has been set correctly. ➤ Ensure windows and doors have been closed properly. ➤ Ensure fi lters are cleaned or replaced when necessary. ➤ Ensure inlet and outlet vents of the units have not been obstructed.
I Operation Details · G Press · Troubleshooting




Powerful, Powerful, Quiet, Quiet, Ion, Fan Speed, Ion, Fan Speed, Air Swing Air Swing

QUIET QUIET

Enables quiet operation.
Enables ion operation.

button to stop the operation.
POWERFUL POWERFUL
Enables powerful operation.
The speed of the indoor fan is
automatically adjusted according to the operation.
FAN SPEE D FAN SPEED
Select fan speed.

Adjust the vertical or horizontal airfl ow direction louver.
G Powerful and Quiet operations could not be activated at the
same time.
G Powerful, Quiet and Ion operations could be cancelled by
pressing the respective button again.

G If you wish to have the cool air blowing directly on you, set the airfl ow direction downward but not for an excessive length of time,
as it may harm your health.
G Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating
operation than the desired temperature.

G ION indicator on the indoor unit is blinking. ➤ Press ION button twice. If the indicator is still blinking, please consult
the dealer.
G Indoor fan stops occasionally during Automatic Fan
➤ This is an advanced feature that helps to remove smell from the
Speed setting.
surrounding area during operation.
G Indoor fan stops occasionally during heating operation.
➤ To avoids unintended cooling effect.
I Operations Details · Troubleshooting




Select ON or OFF timer.
Set the desired time.
Confi rm the setting.
CANCEL CANCEL Cancel the selected timer.

Unit might operate with limited function depending on error found. (Operation starts, 4 “beep” sound is heard)
G Ensure the clock on the remote control has been set
correctly.
G You could use the ON and OFF timers at the same time.
G To cancel either the ON or OFF timer, press

G Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.
G For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.

G TIMER indicator always on. ➤ Timer is activated and the setting will repeat itself daily.
G POWER indicator is blinking 35 minutes before ON
➤ The unit is determining the operation mode by sensing the room
timer is activated.
temperature. This happens when it has been set to AUTO operation mode.




Switch off the power supply Switch off the power supply before cleaning before cleaning
Raise and pull to remove. Wash and dry.


AIR FILTER AIR FILTER


Vacuum, wash and dry.

Part no.: CWD001144
Part no.: CZ-SA13P
IONIZER

I Preparation for extended
SUPERSONIC AIR SUPERSONIC AIR PURIFYING D EVICE PURIFYING DEVICE
Wipe gently.
Vacuum the super alleru-buster fi lter.
Clean with cotton bud.
Vacuum, wash and dry the frame.

G Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling or heating capacity, unpleasant smells and higher
energy consumption.
G The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an
authorized dealer to perform seasonal inspections in addition to regular cleaning.
G This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner
from being damaged by abnormally strong lightning activity, you may switch off the power supply.

10 Installation Instructions
Required tools for Installation Works 1. Philips screw driver 5. Spanner 9. Gas leak detector 13. Multimeter 2. Level gauge 6. Pipe cutter 10. Measuring tape 14. Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3. Electric drill, hole core drill (ø70 mm)
for the model to be installed.
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6. Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
mm.

1. Selection of the installation location. Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. 2. Power supply connection to the room air conditioner. Connect the power supply cord of the room air conditioner to the mains using one of the following method. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. 1. Power supply connection to the receptacle using a power plug.
Use an approved 15A/16A power plug with earth pin for the connection to the socket.
connection. It must be a double pole switch with a minimum 3.5 mm contact gap. 3. Do not release refrigerant. Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite. 4. Installation work. It may need two people to carry out the installation work. 5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.


Indoor/Outdoor Unit Installation Diagram

CZ-4F5, 7, 10BP (E12DK)
SELECT THE BEST LOCATION
INDOOR UNIT
unit.
circulation.
ceiling, fence or other obstacles.
at least 2.3 m.
sunlight or rain, be careful that heat radiation from the condenser is not obstructed.
The indoor unit will actually face a different way.
affected by hot air discharged.
fence or other obstacles.
circuit of the discharged air.
refrigerant should be added as shown in the table.

Attached accessories · Applicable piping kit

10.2. Indoor Unit
10.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
When the wall is hollow, please be sure to use the sleeve for tube ass’y to prevent dangers caused by mice biting the connecting cable.
The mounting wall is strong and solid enough to prevent it from the vibration.


The centre of installation plate should be at more than 450 mm at right and left of the wall.
The distance from installation plate edge to ceiling should more than 67 mm.
From installation plate left edge to unit’s left side is 74 mm.
From installation plate right edge to unit’s right is 94 mm.
:
For left side piping, piping connection for liquid should be about 15 mm from this line. For left side piping, piping connection for gas should be about 45 mm from this line. For left side piping, piping connection cable should be about 800 mm from this line
:
:

more. (If mounting the unit on the concrete wall consider using anchor bolts.)
aligning the marking-off line with the thread and using a level gauge.

and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 150 mm and 125 mm for left and right hole respectively.
hole should be slightly slanted to the outdoor side.






(This can be used for left rear piping & left bottom piping also.)






without removing the front grille.
shall be approved polychloroprene sheathed 4 × 1.5 mm2
flexible cord, type designation 245 IEC 57 or heavier cord.
terminal Nos. are the same to the indoor’s respectively.
as shown in the figure for the electrical safety in case of the slipping out of the cord from the anchorage.


(clamper).


INSTALLATION OF SUPER ALLERU-BUSTER FILTER

air purifying device frame as show in illustration at right.
Please follow the steps below to take out front grille if necessary such as when servicing.

When reinstalling the front grille, first set the vertical airflow direction louver to the horizontal position and then carry out above steps 2 - 3 in the reverse order.
The below operations will be performed by pressing the “AUTO” switch.
The Auto operation will be activated immediately once the Auto Switch is pressed.
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. A “beep” sound will occur at the fifth sec., in order to identify the starting of Test Run operation
The ON/OFF of remote controller receiving sound can be change over by pressing the following step:
a. Release the Auto Switch after Test Run operation is activated.
b. Then, within 20 sec., after a., press Auto Switch for more than 5 sec.
A “beep” “beep” sound will occur at the fifth sec., then release the Auto Switch.
c. Within 20 sec. after b., press Auto Switch again. Everytime Auto Switch is pressed (within 20 sec. interval), remote
controller receiving sound status will be reversed between ON and OFF.
Long “beep” sound indicates that remote controller receiving sound is OFF.
Short “beep” sound indicates that remote controller receiving sound is ON.


10.3. Outdoor Unit
10.3.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section)

to Indoor/Outdoor Unit Installation Diagram.
by bolt nut. (ø10 mm).
earthquake. Please fasten the installation stand firmly with bolt or nails.
Connecting The Piping To Indoor Unit
Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe. (In case of using long piping)
MODEL Piping size (Torque) Gas Liquid E9DK 3/8” (42 N.m) 1/4” (18 N.m) E12DK 1/2” (55 N.m) 1/4” (18 N.m)

Connecting The Piping To Outdoor Unit
Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the flare nut (located at valve) onto the copper pipe.
Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table.

removed, gas leakage may be caused.
Turn the piping end down to avoid the metal powder entering the pipe.
copper pipes.
Connect the piping

10.3.4. EVACUATION OF THE EQUIPMENT
WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure.

-76 cmHg (-0.1 MPa). Then evacuate the air approximately ten minutes.
move after approximately five minutes.
wrench (4 mm).
frostbite.

10.3.5. CONNECT THE CABLE TO THE OUTDOOR UNIT
(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)

the screw.
shall be approved polychloroprene sheathed 4 × 1.5 mm2
flexible cord, type designation 245 IEC 57 or heavier cord.

(clamper).
(Disconnecting means).
supply cable (1.5 mm2), type designation 245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cable to knife switch (Disconnecting means).
Knife switch (Disconnecting means) should have minimum 3 mm contact gap.
− Secure the cable onto the control board with the
holder (clamper).
the insulated piping end to prevent water from going inside the piping.
with thickness 6 mm or above.

stand which is taller than 3 cm.
0°C for 2 or 3 days in succession, it is recommended not to use a drain elbow, for the drain water freezes and the fan will not rotate.

CHECK THE DRAINAGE

(Drainage checking can be carried out without removing the front grille.)
unit.

minutes or more.
the discharge is more than 8°C.
Is the indoor unit properly hooked to the installation plate?
Is there any gas leakage at flare nut connections?
Is the power supply voltage complied with rated value?
Has the heat insulation been carried out at flare nut connection?
Is there any abnormal sound?
Is the connecting cable being fixed to terminal board firmly?
Is the cooling operation normal?
Is the connecting cable being clamped firmly?
Is the thermostat operation normal?
Is the drainage OK? (Refer to “Check the drainage” section)
Is the remote control’s LCD operation normal?
Is the super alleru-buster filter is installed?
Is the earth wire connection properly done?

11 Installation And Servicing Air Conditioner Using R410A
11.1. Outline
11.1.1. About R410A Refrigerant
Since it was declared in1974 that chlorofluorocarbons (CFC), hydro chlorofluorocarbons (HCFC) and other substances pose a destructive danger to the ozone layer in the earth´s upper stratosphere (20 to 40 km above the earth), measures have been taken around the world to prevent this destruction. The R22 refrigerant which has conventionally been used in ACs is an HCFC refrigerant and, therefore, possesses this ozone- destroying potential. International regulations (the Montreal Protocol on Ozone-Damaging Substances) and the domestic laws of various countries call for the early substitution of R22 by a refrigerant which will not harm the ozone layer.
pressure of R410A is approximately 1.6 times as high at the same refrigerant temperature, but the energy efficiency is about the same. Consisting of hydrogen (H), fluorine (F) and carbon (C), R410A is an HFC refrigerant. Another typical HFC refrigerant is R407C. While the energy efficiency of R407C is somewhat inferior to that of R410A, it offers the advantage of having pressure characteristics which are about the same as those of R22, and is used mainly in packaged ACs.
a. Chemical characteristics
The chemical characteristics of R410A are similar to those of R22 in that both are chemically stable, non-flammable refrigerants with low toxicity. However, just like R22, the specific gravity of R410A gas is heavier than that of air. Because of this, it can cause an oxygen deficiency if it leaks into a closed room since it collects in the lower area of the room. It also generates toxic gas when it is directly exposed to a flame, so it must be used in a well ventilated environment where it will not collect.
Table 1 Physical comparison of R410A and R22
R410A R22 Composition (wt%) R32/R125 (50/50) R22 (100) Boiling point (°C) -51.4 -40.8 Vaporizing pressure (25°C) 1.56 Mpa (15.9 kgf/cm2) 0.94 Mpa (9.6 kgf/cm2) Saturated vapor density 64.0 kg/m3 44.4 kg/m3
Flammability Non-flammable Non-flammable Ozone-destroying point (ODP) 0 0.055 Global-warming point (GWP) 1730 1700
b. Compositional change (pseudo-azeotropic characteristics)
R410A is a pseudo-azeotropic mixture comprising the two components R32 and R125. Multi-component refrigerants with these chemical characteristics exhibit little compositional change even from phase changes due to vaporization (or condensation), which means that there is little change in the circulating refrigerant composition even when the refrigerant leaks from the gaseous section of the piping. Accordingly, R410A can be handled in almost the same manner as the single-component refrigerant R22. However, when charging, because there is a slight change in composition between the gas phase and the liquid phase inside a cylinder or other container, charging should basically begin with the liquid side.
c. Pressure characteristics
As seen in Table 2, the gas pressure of R410A is approximately 1.6 times as high as that of R22 at the same refrigerant temperature, which means that special R410A tools and materials with high-pressure specifications must be used for all refrigerant piping work and servicing.
Table 2 Comparison of R410A and R22 saturated vapor density
Unit: MPa Refrigerant Temperature (°C) R410A R22 -20 0.30 0.14 0 0.70 0.40 20 1.35 0.81 40 2.32 1.43 60 3.73 2.33 65 4.15 2.60

d. R410A refrigerating machine oil
Conventionally, mineral oil or a synthetic oil such as alkylbenzene has been used for R22 refrigerating machine oil. Because of the poor compatibility between R410A and conventional oils like mineral oil, however, there is a tendency for the refrigerating machine oil to collect in the refrigerating cycle. For this reason, polyester and other synthetic oils which have a high compatibility with R410A are used as refrigerating machine oil. Because of the high hygroscopic property of synthetic oil, more care must be taken in its handling than was necessary with conventional refrigerating machine oils. Also, these synthetic oils will degrade if mixed with mineral oil or alkylbenzene, causing clogging in capillary tubes or compressor malfunction. Do not mix them under any circumstances.
Cause the gas pressure of R410A is approximately 1.6 times as high as that of R22, a mistake in installation or servicing could result in a major accident. It is essential that you use R410A tools and materials, and that you observe the following precautions to ensure safety.
to a direct flame.
it does, the pressure in the refrigeration cycle can become abnormally high, possibly causing an explosion and/or injury.
result in an abnormal refrigeration cycle or water leakage, electric shock, fire, etc.
repairs can result in an water leakage, electric shock, fire, etc.
In order to prevent an R410A AC from mistakenly being charged with any other refrigerant, the diameter of the 3-way valve service port on the outdoor unit has been changed. Also, to increase its ability to withstand pressure, the opposing dimensions have been changed for the refrigerant pipe flaring size and flare nut. Accordingly, when installing or servicing refrigerant piping, you must have both the R410A and ordinary tools listed below.
Table 3 Tools for installation, transferring or replacement Type of work Ordinary tools R410A tools Flaring Flaring tool (clutch type), pipe cutter, reamer
Copper pipe gauge for clearance Adjustment, flaring tool (clutch type)*1) Bending, connecting pipes Torque wrench (nominal diameter 1/4, 3/8,1/2). Fixed spanner (opposing sides 12 mm, 17 mm, 19 mm). Adjustable wrench, Spring bender Air purging Vacuum pump. Hexagonal wrench (opposing sides 4 mm)
Manifold gauge, charging hose, vacuum pump adaptor Gas leak inspection Gas leak inspection fluid or soapy water Electric gas leak detector for HFC refrigerant*2)
*1) You can use the conventional (R22) flaring tool. If you need to buy a new tool, buy the R410A type.
*2) Use when it is necessary to detect small gas leaks.
For other installation work, you should have the usual tools, such as screwdrivers (+,-), a metal-cutting saw, an electrical drill, a hole core drill (65 or 70 dia.), a tape measure, a level, a thermometer, a clamp meter, an insulation tester, a voltmeter, etc.
Table 4 Tools for serving Type of work Ordinary tools R410A tools Refrigerant charging Electronic scale for refrigerant charging. Refrigerant cylinder. Charging orifice and packing for refrigerant cylinder Brazing (Replacing refrigerating cycle part*1)
Nitrogen blow set (be sure to use nitrogen blowing for all brazing), and brazing machine
*1) Always replace the dryer of the outdoor unit at the same time. The replacement dryer is wrapped in a vacuum pack. Replace it last among the refrigerating cycle parts. Start brazing as soon as you have opened the vacuum pack, and begin the vacuuming operation within 2 hours.

11.2.2. R410A Tools

(used when flaring with the conventional flaring tool (clutch type))
copper tube to 1.0-1.5 mm from the clamp bar of the flaring tool.
Fig. 1 Copper tube gauge for clearance adjustment

clamp bar is enlarged so the clearance from the clamp bar can be set to 0-0.5 mm, and the spring inside the tool is strengthened to increase the strength of the pipe- expanding torque. This flaring tools can also be used with R22 piping, so we recommend that you select it if you are buying a new flaring tool.
Fig. 2 Flaring tool (clutch type)

Fig. 3 Torque wrenches
Table 5 Conventional wrenches R410A wrenches For 1/4 (opposite side x torque) 17 mm x 18 N.m (180 kgf.cm) 17 mm x 18 N.m (180 kgf.cm) For 3/8 (opposite side x torque) 22 mm x 42 N.m (420 kgf.cm) 22 mm x 42 N.m (420 kgf.cm) For 1/2 (opposite side x torque) 24 mm x 55 N.m (550 kgf.cm) 26 mm x 55 N.m (550 kgf.cm)
Table 6 Difference between R410A and conventional high / low-pressure gauges
Conventional gauges R410A gauges High-pressure gauge (red) -76 cmHg - 35 kgf/cm3 -0.1 - 5.3 Mpa -76 cmHg - 53 kgf/cm3
Low-pressure gauge (blue) -76 cmHg - 17 kgf/cm3 -0.1 - 3.8 Mpa -76 cmHg - 38 kgf/cm3
refrigerant.
Table 7 Difference between R410A and conventional manifold port size
Conventional gauges R410A gauges Port size 7/16 UNF 20 threads 1/2 UNF 20 threads


raised to match the higher pressure of R410A. The hose material has also been changed to suit HFC use, and the size of the fitting has been changed to match the manifold ports.
Fig. 4 Manifold gauge charging hose
Table 8 Difference between R410A and conventional charging hoses
Conventional hoses R410A hoses Pressure resistance
Working pressure 3.4 MPa (35 kgf/cm3) 5.1 MPa (52 kgf/cm3) Bursting pressure 17.2 MPa (175 kgf/cm3) 27.4 MPa (280 kgf/cm3) Material NBR rubber HNBR rubber Nylon coating inside

to install an electromagnetic valve to prevent the vacuum pump oil from flowing back into the charging hose. The vacuum pump adaptor is installed for that purpose. if the vacuum pump oil (mineral oil) becomes mixed with R410A, it will damage the unit.
Fig. 5 Vacuum pump adaptor

CFC and HCFC cannot be used with R410A (because there is no chlorine in the refrigerant).
detection sensitivity will be lower (setting the sensitivity for R134a at 1, the level for R410A will drop to 0.6).
electric gas leak detector for HFC refrigerant. (Detection sensitivity with R410A is about 23 g/year).
Fig. 6 Electric gas leak detector for HFC refrigerant


of R410A, the refrigerant cannot be held in a liquid phase inside the charging cylinder when charging is done using the charging cylinder method, causing bubbles to form in the measurement scale glass and making it difficult to see the reading. (Naturally, the conventional R22 charging cylinder cannot be used because of the differences in the pressure resistance, scale gradation, connecting port size, etc.)
structure in which the weight detector for the refrigerant cylinder is held by four supports. It is also equipped with two connection ports, one for R22 (7/16 UNF, 20 threads) and one for R410A (1/2 UNF, 20 threads), so it can also be used for conventional refrigerant charging.
Fig. 7 Electronic scale for refrigerant charging
cylinders and one for 20-kg cylinders. (The 10-kg cylinder is recommended.)
Refrigerant charging is done manually by opening and closing the valve.

name, and the coating color of the cylinder protector is pink, which is the color stipulated by ARI of the U.S.
allow the cylinder to stand upright for liquid refrigerant charging.
Fig. 8 Refrigerant cylinders

hose fitting (1/2 UNF, 20 threads).
material.
Fig. 9 Charging orifice and packing
Table 9 R410A tools which are usable for R22 models
R410A tools Usable for R22 models (1) Copper tube gauge for clearance adjustment OK (2) Flaring tool (clutch type) OK (3) Manifold gauge NG (4) Charging hose NG (5) Vacuum pump adaptor OK (6) Electric gas leak detector for HFC refrigerant NG (7) Electronic scale for refrigerant charging OK (8) Refrigerant cylinder NG (9) Charging orifice and packing for refrigerant cylinder NG

11.3. Refrigerant Piping Work
11.3.1. Piping Materials
It is recommended that you use copper and copper alloy jointless pipes with a maximum oil adherence of 40 mg/10m. Do not use pipes that are crushed, deformed, or discolored (especially the inside surface). If these inferior pipes are used, impurities may clog the expansion valves or capillaries. Because the pressure of ACs using R410A is higher than those using R22, it is essential that you select materials that are appropriate for these standards. The thickness of the copper tubing used for R410A is shown in Table 10. Please be aware that tubing with a thickness of only 0.7 mm is also available on the market, but this should never be used.
Table 10 Copper tube thickness (mm) Soft pipe Thickness (mm) Nominal diameter Outside diameter (mm) R410A (Reference) R22 1/4 6.35 0.80 0.80 3/8 9.52 0.80 0.80 1/2 12.7 0.80 0.80
When working with refrigerant piping, the following points must be carefully observed: no moisture od dust must be allowed to enter the piping, and there must be no refrigerant leaks.

a. Cut the pipe
Use a pipe cutter, and cut slowly so the pipe will not be deformed.
b. Remove burrs and clean shavings from the cut surface
If the shape of the pipe end is poor after removing burrs, or if shavings adhere to the flared area, it may lead to refrigerant leaks. To prevent this, turn the cut surface downward and remove burrs, then clean the surface, carefully.
Fig. 10 Flaring dimensions
c. Insert the flare nut (be sure to use the same nut that is
used on the AC unit)
d. Flaring
Check the clamp bar and the cleanliness of the copper pipe. Be sure to use the clamp bar to do the flaring with accuracy. Use either an R410A flaring tool, or a conventional flaring tool. flaring tools come in different sizes, so be sure to check the size before using. When using a conventional flaring tool, use the copper pipe gauge for clearance adjustment, etc., to ensure the correct A dimension (see Fig. 10)

Fig. 11 Relation between the flare nut structure and flaring tool end

Table 11 R410A flaring dimensions Nominal diameter
A (mm) R410A flaring tool, clutch type
Conventional flaring tool Clutch type Wing-nut type 1/4 6.35 0.8 0 - 0.5 1.0 - 1.5 1.5 - 2.0 3/8 9.52 0.8 0 - 0.5 1.0 - 1.5 1.5 - 2.0 1/2 12.70 0.8 0 - 0.5 1.0 - 1.5 2.0 - 2.5
Table 12 R22 flaring dimensions Nominal diameter
A (mm) R410A flaring tool, clutch type
Conventional flaring tool Clutch type Wing-nut type 1/4 6.35 0.8 0 - 0.5 0.5 - 1.0 1.0 - 1.5 3/8 9.52 0.8 0 - 0.5 0.5 - 1.0 1.0 - 1.5 1/2 12.70 0.8 0 - 0.5 0.5 - 1.0 1.5 - 2.0
Table 13 R410A flare and flare nut dimensions Unit: mm Nominal diameter
A +0, -0.4 B dimension
width 1/4 6.35 0.8 9.1 9.2 6.5 13 17 3/8 9.52 0.8 13.2 13.5 9.7 20 22 1/2 12.70 0.8 16.6 16.0 12.9 23 26
Table 14 R22 flare and flare nut dimensions Unit: mm Nominal diameter
A +0, -0.4 B dimension
width 1/4 6.35 0.8 9.0 9.2 6.5 13 17 3/8 9.52 0.8 13.0 13.5 9.7 20 22 1/2 12.70 0.8 16.2 16.0 12.9 20 24
a. Check to make sure there is no scratches, dust, etc., on the flare and union.
b. Align the flared surface with the axial center of the union.
c. Use a torque wrench, and tighten to the specified torque. The tightening torque for R410A is the same as the conventional
torque value for R22. Be careful, because if the torque is too weak, it may lead to a gas leak. If it is too strong, it may split the flare nut or make it impossible to remove the flare nut.
Table 15 R410A tightening torque Nominal diameter
Torque wrench tightening torque
N.m (kgf.cm) 1/4 6.35 14 - 18 (140 - 180) 18 (180) 3/8 9.52 33 - 42 (330 -420) 42 (420) 1/2 12.70 55 (550) 55 (550)
N.m (kgf.cm)
The following is a general classification of the refrigerant pipe materials used for ACs.

Because the gas pressure of R410A is approximately 1.6 times as high as that of R22, copper pipes with the thickness shown in Table 10, and with minimal impurities must be used. Care must also be taken during storage to ensure that pipes are not crushed, deformed, or scratched, and that no dust, moisture or other substance enters the pipe interior. When storing sheathed copper pipes or plain copper pipes, seal the openings by pinching or taping them securely.
a. Sheathed copper pipes and copper-element pipes
When using these pipes, check to make sure that they are the stipulated thickness. For flare nuts, be sure to used the same nut that is used on the AC unit.

b. Copper pipes
Use only copper pipes with the thickness given in table 10, and with minimal impurities. Because the surface of the pipe is exposed, you should take special care, and also take measures such as marking the pipes to make sure they are easily distinguished from other piping materials, to prevent mistaken use.
Take the following precautions on-site when connecting pipes. (Keep in mind that the need to control the entry of moisture and dust is even more important that in conventional piping).
a. Keep the open ends of all pipes sealed until connection with AC equipment is complete.
b. Take special care when doing piping work on rainy days. The entering of moisture will degrade the refrigerating machine oil,
and lead to malfunctions in the equipment.
c. Complete all pipe connections in as short a time as possible. If the pipe must be left standing for a long time after removing
the seal, it must be thoroughly purged with nitrogen, or dried with a vacuum pump.
11.4.1. Inspecting Gas Leaks with a Vacuum Pump for New Installations (Using New Refrigerant Piping)
a. Connect the projecting side (pin-pushing side) of the charging hose for the manifold gauge to the service port of the 3-way
valve. (1)
b. Fully open the handle Lo of the manifold gauge and run the vacuum pump. (2) (If the needle of the low-pressure gauge
instantly reaches vacuum, re-check step a).)
c. Continue the vacuum process for at least 15 minutes, then check to make sure the low-pressure gauge has reached -0.1
MPa (-76 cmHg). Once the vacuum process has finished, fully close the handle Lo of the manifold gauge and stop the vacuum pump operation, then remove the charging hose that is connected to the vacuum pump adaptor. (Leave the unit in that condition for 1-2 minutes, and make sure that the needle of the manifold gauge does not return.) (2) and (3)
d. Turn the valve stem of the 2-way valve 90° counter-clockwise to open it, then, after 10 seconds, close it and inspect for a
e. Remove the charging hose from the 3-way valve service port, then open both the 2-way valve and 3-way valve. (1) (4) (Turn
the valve stem in the counter-clockwise direction until it gently makes contact. Do not turn it forcefully).
f. Tighten the service port cap with a torque wrench (18 N.m (1.8 kgf.m)). (5) Then tighten the 2-way valve and 3-way valve
caps with a torque wrench (42 N.m (4.2 kgf.m)) or (55 N.m (5.5 kgf.m)). (6)
g. After attaching each of the caps, inspect for a gas leak around the cap area. (5) (6)

vacuum pump adaptor and manifold gauge prior to use, and follow the instructions carefully.
the designated line on the oil gauge.
charging hose is generally open during use. When you are removing the charging hose from the service port, it will come off more easily if you close this valve.
Fig. 12 Vacuum pump air purging configuration
gas leak (4) · Precautions

11.4.2. Transferring (Using New Refrigerant Piping)
a. Collecting the refrigerant into the outdoor unit by pumping down
The refrigerant can be collected into the outdoor unit (pumping down) by pressing the TEST RUN button, even when the temperature of the room is low.
clockwise. (Remove the valve stem caps and check to see that the valve stems are fully opened position. Always use a hex wrench (with 4-mm opposing sides) to operate the valve stems.)
the clockwise direction.
way valve quickly in the clockwise direction to close it, then stop the operation.
b. Removing the indoor and outdoor units.
foreign matter enters.
Install the unit using new refrigerant piping. Follow the instructions in section 4.1 to evacuate the pipes connecting the indoor and outdoor units, and the pipes of the indoor unit, and check for gas leaks.
When replacing an R410A AC unit with another R410A AC unit, you should re-flare the refrigerant piping. Even though the replacement AC unit uses the R410A, problems occur when, for example, either the AC unit maker or the refrigerating machine oil is different. When replacing an R22 AC unit with an R410A AC unit, the following checks and cleaning procedures are necessary but are difficult to do because of the chemical characteristics of the refrigerating machine oil (as described in items c) and d) of section About R410A Refrigerant). In this case, you should use new refrigerant piping rather than the existing piping.
Because of the different pressure characteristics of R22 and R410A, the design pressure for the equipment is 1.6 times different. the wall thickness of the piping must comply with that shown in Table 10, but this is not easy to check. Also, even if the thickness is correct, there may be flattened or bent portions midway through the piping due to sharp curves. Buried sections of the piping also cannot be checked.
A large quantity of refrigerating machine oil (mineral oil) adheres to existing pipes due to the refrigeration cycle circulation. If the pipes are used just as they are for the R410A cycle, the capacity will be lowered due to the incompatibility of this oil with the R410A, or irregularities may occur in the refrigeration cycle. For this reason, the piping must be thoroughly cleaned, but this is difficult with the present technology.
Do not operate an existing R22 AC with the new R410A refrigerant. Doing so would result in improper functioning of the equipment or malfunction, and might lead to a major accident such as an explosion in the refrigeration cycle. Similarly, do not operate an R410A AC with R22 refrigerant. The chemical reaction between the refrigerating machine oil used in R410A ACs and the chlorine that is contained in R22 would cause the refrigerating machine oil to degrade and lead to malfunction.

11.4.5. Recharging Refrigerant During Servicing
When recharging is necessary, insert the specified amount of new refrigerant in accordance with the following procedure.
at least one hour.
vacuum pump. Wait for 1-2 minutes, then check to make sure that the needle of the Low pressure gauge has not returned. See Fig. 13 for the remaining steps of this procedure.
electronic scale. (1)(2)
Precaution:
Be sure to set up the cylinder for liquid charging. If you use a cylinder equipped with a siphon tube, you can charge the liquid without having to turn the cylinder around
electronic scale. (2)(3)
manifold gauge and purge the air. (2)(4) (Watch the liquid refrigerant closely at this point.)
with the liquid refrigerant. (2)(5) (Be sure to read the operating instructions for the electronic scale.)
(about 150 g/time as a guideline). If the charging amount is insufficient from one operation, wait about one minute, then use the same procedure to do the liquid charging again.
Precaution:
Never use the gas side to allow a larger amount of liquid refrigerant to be charged while operating the unit.
manifold gauge, and stop the operation of the unit. (2)(5)
be discharged.

Fig. 13 Re-charging refrigerant

11.4.6. Brazing
As brazing requires sophisticated techniques and experiences, it must be performed by a qualified person. In order to prevent the oxide film from occurring in the pipe interior during brazing, it is effective to proceed with brazing while letting dry nitrogen gas (N2) flow.
<Brazing Method for Preventing Oxidation>
from flowing backward.
which pipes are touchable with finger).

Fig. 14 Prevention of Oxidation during Brazing
a. The brazing strength should be high as required.
b. After operation, airtightness should be kept under pressurized condition.
c. During brazing do not allow component materials to become damaged due to overheating.
d. The refrigerant pipe work should not become blocked with scale or flux.
e. The brazed part should not restrict the flow in the refrigerant circuit.
f. No corrosion should occur from the brazed part.
Due to heating, the interior and exterior surfaces of treated metal may oxidize. Especially, when the interior of the refrigerant circuit oxidizes due to overheating, scale occurs and stays in the circuit as dust, thus exerting a fatally adverse effect. So, make brazing at adequate brazing temperature and with minimum of heating area.
In order to prevent components near the brazed part from overheating damage or quality deterioration due to flame or heat, take adequate steps for protection such as (1) by shielding with a metal plate, (2) by using a wet cloth, and (3) by means of heat absorbent.
Eliminate all vibration during brazing to protect brazed joints from cracking and breakage.
In order to improve the brazing efficiency, various types of antioxidant are available on the market. However, the constituents of these are widely varied, and some are anticipated to corrode the piping materials, or adversely affect HFC refrigerant, lubricating oil, etc. Exercise care when using an oxidation preventive.
The drier must also be replaced whenever replacing the refrigerant cycle parts. Replacing the refrigerant cycle parts first before replacing the drier. The drier is supplied in a vacuum pack. Perform brazing immediately after opening the vacuum pack, and then start the vacuum within two hours. In addition, the drier also needs to be replaced when the refrigerant has leaked completely. (Applicable for drier models only)

12 Servicing Information
a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
During troubleshooting and servicing, rated compressor operating frequency must be obtained in order to check the specification and technical data. Below are the methods used to obtain rated compressor operating specification.
(i) Press the Auto button continuously for 5 seconds or less than 8 seconds, the air conditioner starts operation at Cooling rated frequency.
(“beep” will be heard at the 5th second.)

(ii) Short the service terminal (CN-S) of the outdoor printed circuit board. The operation of air conditioner is Cooling rated frequency.

Press the Auto button continuously for 8 seconds or less than 11 seconds, the air conditioner starts operation at Heating rated frequency. (“beep” “beep” will be heard at the 8th second.)
(a) Cooling · (b) Heating


In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right.

Refrigeration cycle system

Cooling Mode Heating Mode Condition of the air
conditoner Low Pressure High Pressure Electric current during operation
Low Pressure High Pressure Electric current during operation
Insufficient refrigerant (gas leakage)
Clogged capillary tube or Strainer
Short circuit in the indoor unit
Heat radiation deficiency of the outdoor unit
Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below breakdown diagnosis method:
be displayed at remote controller.
” button once, next error code will be displayed; press “V” button once, previous error code will be displayed.
be heard for 4 seconds and Power LED will light on. Otherwise, one “beep” sound is heard.
If “CHECK” button is press again or without any operation for 30 seconds, the diagnosis mode will turn off.
Inefficient compression

Abnormality / Protection control Abnormality
Primary location to verify
H11 Indoor / outdoor abnormal communication
> 1 min after starting operation
Continue for 5 sec. — • Intake air temperature sensor
(detective or disconnected) H15 Outdoor compressor temperature sensor abnormality
Continue for 5 sec. — • Compressor temperature sensor
(detective or disconnected) H16 Outdoor Current Transformer open circuit
— — • Outdoor PCB
Continue for 5 sec. O (Cooling only)
(defective or disconnected) H26 Ionizer breakdown — — • Ionizer H27 Outdoor air temperature sensor abnormality
Continue for 5 sec. O • Outdoor temperature sensor
(defective or disconnected) H28 Outdoor heat exchanger temperature sensor abnormality
Continue for 5 sec. O • Outdoor heat exchanger
— — • Insufficient refrigerant
4 times occurance within 30 minutes
— • 4-way valve
— • Voltage at PFC
F91 Refrigeration cycle abnormality 2 times occurance within 20 minutes
— • No refrigerant
(3-way valve is closed) F93 Compressor rotation failure — — • Compressor F95 Cool high pressure protection 4 times occurance within 20 minutes
— • Outdoor refrigerant circuit
F96 IPM (power transistor) overheating protection
— — • Excess refrigerant
4 times occurance within 10 minutes
— • Insufficient refrigerant
— • Excess refrigerant
7 times occurance continuously
— • Outdoor PCB
“O” - Frequency measured and fan speed fixed.
The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard following by pressing the “RESET” button at remote controller.
Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Codes Table) by using remote controller or Auto Switch at indoor unit. However, the remote controller signal receiving sound is changed from one “beep” to four “beep” sounds.

12.3. Remote Control

When the batteries are inserted for the first time, or the batteries are replaced, all the indications will blink and the remote control might not work.
If this happen, remove the cover of the remote control and push the reset point once to clear the memory data.

When there are more than one indoor units installed in the same room, it is possible to set different remote control receiving signal by modifying the jumpers inside remote controller.

code

12.4. Disassembly of Parts
a. Indoor Control Board Removal Procedures






b. Electronic Controller Removal Procedures


c. Cross Flow Fan and Fan Motor Removal Procedures




d. Outdoor Electronic Controller Removal Procedure

sink cover so never touch the interior during operation. Wait at least two minutes after power has been turned off.





13 Technical Data
13.1. Operation Characteristics
13.1.1. CS-E9DKEW CU-E9DKE


13.1.2. CS-E12DKEW CU-E12DKE



30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0°C 2.58 1.96 0.55 2.41 1.88 0.59 2.24 1.80 0.63 2.04 1.71 0.68 19.0°C 2.60 0.60 19.5°C 2.83 2.05 0.56 2.65 1.97 0.60 2.46 1.89 0.64 2.24 1.80 0.69 22.0°C 3.09 2.12 0.57 2.88 2.04 0.61 2.68 1.97 0.66 2.44 1.88 0.71
30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0°C 3.47 2.63 0.88 3.24 2.52 0.95 3.02 2.43 1.02 2.74 2.30 1.10 19.0°C 3.50 0.97 19.5°C 3.81 2.76 0.90 3.56 2.65 0.97 3.31 2.55 1.04 3.01 2.43 1.12 22.0°C 4.15 2.86 0.92 3.88 2.75 0.99 3.61 2.65 1.05 3.28 2.53 1.14

14 Exploded View (Indoor Unit)
14.1. CS-E9DKEW CS-E12DKEW

The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.

15 Replacement Parts List (Indoor Unit)
15.1. CS-E9DKEW CS-E12DKEW
REF. NO. PART NAME & DESCRIPTION QTY. CS-E9DKEW CS-E12DKEW REMARKS 1 CHASSY COMPLETE 1 CWD50C1431 ← 2 FAN MOTOR 1 CWA981149 ← 0 3 CROSS FLOW FAN COMPLETE 1 CWH02C1031 ← 4 BEARING ASS’Y 1 CWH64K007 ← 5 SCREW - CROSS FLOW FAN 1 CWH4580304 ← 6 EVAPORATOR 1 CWB30C1597 CWB30C1726 7 FLARE NUT 1 CWT25086 (1/4”) ← 8 FLARE NUT 1 CWT25087 (3/8”) CWT25096 (1/2”) 9 HOLDER SENSOR 1 CWH32143 ← 10 DISCHARGE GRILLE COMPLETE 1 CWE20C2343 ← 11 VERTICAL VANE 9 CWE241150 ← 12 CONNECTING BAR 1 CWE261072 ← 13 CONNECTING BAR 1 CWE261065 ← 14 AIR SWING MOTOR 2 CWA98260 ← 0 15 LEAD WIRE - AIR SWING MOTOR 1 CWA67C3849 ← 16 CAP - DRAIN TRAY 1 CWH521096 ← 17 HORIZONTAL VANE 1 CWE241173 ← 18 BACK COVER CHASSIS 1 CWD932454 ← 19 CONTROL BOARD CASING 1 CWH102259 ← 20 TERMINAL BOARD COMPLETE 1 CWA28C2082 ← 0 21 POWER SUPPLY CORD 1 - - 22 ELECTRONIC CONTROLLER - MAIN 1 CWA73C1667 CWA73C1668 0 23 LEAD WIRE - AIR SWING MOTOR 1 CWA67C3977 ← 0 24 SENSOR COMPLETE 1 CWA50C2122 ← 0 25 CONTROL BOARD FRONT COVER 1 CWH13C1120 ← 26 INDICATOR COMPLETE 1 CWE39C1126 ← 0 27 INDICATOR HOLDER 1 CWD932429 ← 28 INDICATOR HOLDER 1 CWD932430 ← 29 CONTROL BOARD TOP COVER 1 CWH131207 ← 30 REMOTE CONTROL COMPLETE 1 CWA75C2616 ← 0 31 FRONT GRILLE COMPLETE 1 CWE11C3138 ← 0 32 INTAKE GRILLE 1 CWE22C1154 ← 33 GRILLE DOOR 1 CWE141073 ← 34 AIR FILTER 2 CWD001144 ← 35 SCREW - FRONT GRILLE 2 XTT4+16C ← 36 CAP - FRONT GRILLE 2 CWH521109 ← 37 DRAIN HOSE 1 CWH851063 ← 38 INSTALLATION PLATE 1 CWH361067 ← 39 BAG COMPLETE - INSTALLATION SCREW 1 CWH82C067 ← 40 FULCRUM 1 CWH621046 ← 41 ELECTRONIC CONTROLLER - IONIZER 1 CWA743675 ← 0 42 CASING - IONIZER 1 CWD932464 ← 43 CASING - IONIZER 1 CWD932431 ← 44 ION GENERATOR 1 CWH94C0001 ← 45 SUPERSONIC AIR PURIFYING DEVICE 1 CWH91C1013 ← 46 ELECTRONIC CONTROLLER SUPERSONIC 1 CWA743874 ← 0 47 SUPER ALLERU BUSTER FILTER 1 CWD00C1133 ← 48 FRAME FR AIR FILTER SUPERSONIC 1 CWD011026 ← 49 FRAME FR AIR FILTER SUPERSONIC 1 CWD011027 ←
(Note)

16 Exploded View (Outdoor Unit)
16.1. CU-E9DKE CU-E12DKE

The above exploded view is for the purpose of parts disassembly and replacement.
The non-numbered parts are not kept as standard service parts.

17 Replacement Parts List (Outdoor Unit)
17.1. CU-E9DKE CU-E12DKE
REF NO. DESCRIPTION & NAME QTY. CU-E9DKE CU-E12DKE REMARKS 1 CHASSY ASSY 1 CWD50K2073 ← 2 ANTI-VIBRATION BUSHING 3 CWH50077 ← 3 COMPRESSOR 1 5RS102XBC01 ← O 4 NUT-COMPRESSOR MOUNT 3 CWH56000 ← 5 SOUND PROOF MATERIAL 1 CWG302293 ← 6 FAN MOTOR BRACKET 1 CWD541030 ← 7 FAN MOTOR 1 CWA951418 CWA951309 O 8 SCREW - FAN MOTOR BRACKET 2 CWH551060 ← 9 SCREW - FAN MOTOR MOUNT 4 CWH55406 ← 10 PROPELLER FAN ASSY 1 CWH03K1006 ← 11 NUT - PROPELLER FAN 1 CWH56053 ← 12 CONDENSER 1 CWB32C1560 CWB32C1599 13 TUBE ASS’Y CO (CAP./CHK VALVE) 1 CWT01C3257 CWT01C3258 14 HOLDER-COUPLING COMPLETE 1 CWH351023 ← 15 3 WAYS VALVE 1 CWB011296 CWB011297 O 16 4 WAYS VALVE 1 CWB001037 ← O 17 SOUND PROOF MATERIAL 1 CWG302292 ← 18 2 WAYS VALVE 1 CWB021255 ← O 19 DRYER 1 CWB101017 ← O 20 V-COIL COMPLETE 1 CWA43C2143 ← O 21 REACTOR 1 CWA421050 - 22 SENSOR COMPLETE 1 CWA50C2196 ← 23 CONTROL BOARD CASING 1 CWH102273 ← 24 TERMINAL BOARD ASSY 1 CWA28K1110 ← 25 FUSE HOLDERS 1 K5D203BBA002 ← 26 CONTROL BOARD 1 CWH102114 ← 27 CONTROL BOARD 1 CWH102115 ← 28 ELECTRONIC CONTROLLER 1 CWA73C1672R CWA73C1673R O 29 CONTROL BOARD COVER 1 CWH131104 ← 30 SENSOR COMPLETE 1 CWA50C2066 ← 31 HOLDER SENSOR 1 CWH321010 ← 32 TERMINAL COVER 1 CWH171001 ← 33 NUT-TERMINAL COVER 1 CWH7080300 ← 34 CABINET SIDE PLATE CO. 1 CWE04C1011 ← 35 CABINET SIDE PLATE (LEFT) 1 CWE041031A ← 36 HANDLE 1 CWE161010 ← 37 WIRE NET 1 CWD041054A ← 38 CABINET FRONT PLATE CO. 1 CWE06C1039 ← 39 CABINET TOP PLATE 1 CWE031014A ← 40 CONTROL BOARD COVER 1 CWH131110 ← 41 CONTROL BOARD COVER 1 CWH131093 ← 42 OPERATING INSTRUCTION (ENG., ESP., ITA., NED., POR., GRE., BUL.)
43 INSTALLATION INSTRUCTION (ENG., ESP., FRA., DEU.) 1 CWF612674 ← 44 L-TUBE 1 CWH5850080 ← 45 INSTALLATION INSTRUCTION (NED., GRE., ITA., POR.) 1 CWF612675 ← 46 INSTALLATION INSTRUCTION (BUL.) 1 CWF612676 ← 47 OPERATING INSTRUCTION (FRA., DEU., SWE., NOR.) 1 CWF564445 ← 48 PACKING-L.TUBE 1 CWB81012 ← 49 SOUND PROOF BOARD 1 CWH151025 ←
(Note)


C32 100µ 25V R69 6.2kΩ 1/4W R70 6.2kΩ 1/4W


R33 10kΩ R34 10kΩ R35 10kΩ


72 73 74 75 76 77 78 79 80
21 22 23 24 25 26 27 28 29
1µ C14 0.01µ C15 0.01µ C09






92 93 94 95 96 97 98 99 100
31 32 33 34 35 36 37 38 39


R86 510Ω 1/4W R87 10k R91 33Ω 1/4W



How to use electronic circuit diagram


18.3. Remote Control


18.4. Print Pattern Indoor Unit Printed Circuit Board


18.5. Print Pattern Outdoor Unit Printed Circuit Board

[PHAAM] Printed in Malaysia