Table of Contents 39 sections Operating Instructions Air Conditioner · Model No. Indoor Unit Outdoor Unit CS-E9PB4EA CS-E12PB4EA · CU-E9PB4EA CU-E12PB4EA · F569176 · … ShowHide
Page 1 of the Panasonic CU-E12PB4EA user manual — F569176
Page 1 · click to enlarge
Page 1

Operating Instructions Air Conditioner

Panasonic CU-E12PB4EA — Operating Instructions Air Conditioner diagram (page 1)
Fig. 1 · Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Български Português Español Français Eλληνικά Italiano Nederlands Deutsch English

* Kindly consult authorised dealer for connectivity validity.

* Wenden Sie sich bei Fragen zur Gültigkeit der Konnektivität an Ihren Fachhändler.

* Wij verzoeken u vriendelijk een geautoriseerde dealer advies te vragen over de aansluitmogelijkheden.

Model No. Indoor Unit Outdoor Unit CS-E9PB4EA CS-E12PB4EA

CU-E9PB4EA CU-E12PB4EA

Istruzioni di funzionamento Condizionatore d’aria

* Si prega di consultare un rivenditore autorizzato per la validità della connettività.

* Outdoor Unit Multi Split CU-2E15PBE CU-2E18PBE CU-3E18PBE CU-4E23PBE CU-4E27PBE CU-5E34PBE

* Συμβουλευτείτε τον εξουσιοδοτημένο αντιπρόσωπο για την καταλληλότητα της σύνδεσης.

Comment utiliser l’appareil Climatiseur

* Consultez un revendeur agréé pour connaître la validité de la connectivité.

Instrucciones de funcionamiento Climatizador de aire

* Consulte a un distribuidor autorizado para conocer la validez de la conectividad.

Instruções de funcionamento Aparelho de ar condicionado

* Consulte o representante autorizado para validar a conectividade.

Инструкции за работа Климатик 66-73

* Моля, обърнете се към оторизиран дилър относно валидността на връзките.

F569176

Bedienungsanleitung Klimagerät · Handleiding Airconditioner · Οδηγίες λειτουργίας Κλιματιστικό

Page 2 of the Panasonic CU-E12PB4EA user manual — Operation conditions
Page 2 · click to enlarge
Page 2

Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.

Multi air conditioner system Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. • For complete product features, please refer catalogue.

Indoor units

Panasonic CU-E12PB4EA — Indoor units diagram (page 2)
Fig. 2 · Indoor units
  • Indoor units
  • It is possible to operate the indoor units individually or simultaneously. The priority of operation is placed on the fi rst unit that turned on.
  • During operation, HEAT and COOL modes cannot activate at the same time for different indoor units.
  • The power indicator blinks to indicate the indoor unit is standing by for a different operation mode.

Outdoor unit

Panasonic CU-E12PB4EA — Outdoor unit diagram (page 2)
Fig. 3 · Outdoor unit

Operation conditions

Use this air conditioner under the following temperature range. DBT : Dry bulb temperature WBT : Wet bulb temperature

Panasonic CU-E12PB4EA — Operation conditions diagram (page 2)
Fig. 4 · Operation conditions
CU-E9PB4EA, CU-E12PB4EAIndoorOutdoor DBTWBTDBT WBT COOLMax.322343 26 Min.1611-10 - HEATMax.30-24 18 Min.16--10 - Multi split outdoor unit CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E23PBE, CU-4E27PBE, CU-5E34PBEIndoorOutdoor DBTWBTDBT WBT COOLMax.322346 26 Min.1611-10 - HEATMax.30-24 18 Min.16--15 -16
Page 3 of the Panasonic CU-E12PB4EA user manual — Indoor units
Page 3 · click to enlarge
Page 3
Page 3 of the Panasonic CU-E12PB4EA user manual — Indoor units
Page 4 of the Panasonic CU-E12PB4EA user manual — Power supply
Page 4 · click to enlarge
Page 4

Safety precautions

To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:

WARNING

Indoor unit and outdoor unit

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

This sign warns of injury or damage to property.

CAUTION

The instructions to be followed are classifi ed by the following symbols:

Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.

This symbol denotes an action that is PROHIBITED.

Confi rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.

These symbols denote actions COMPULSORY.

Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.

Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not expose yourself directly to cold air for a long period to avoid excess cooling.

Do not sit or step on the unit, you may fall down accidentally.

Remote control

Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.

Air outlet Air outlet

Air inlet Air inlet

Power supply

Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.

Air inlet Air inlet

Air outlet Air outlet

Show 4 more labels / short text on this page
Indoor unit · Power supply · Remote control · Outdoor unit
Page 5 of the Panasonic CU-E12PB4EA user manual — Indoor unit and outdoor unit
Page 5 · click to enlarge
Page 5
  • To prevent overheating, fi re or electric shock:
  • Do not share the same power outlet with other equipment.
  • Do not operate with wet hands.
  • Do not over bend the power supply cord.

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.

Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.

If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard.

Do not expose plants or pet directly to airfl ow to avoid injury, etc.

Do not touch the sharp aluminium fi n, sharp parts may cause injury.

It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.

Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.

  • Stop using the product if any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure
  • The ELCB trips frequently.
  • Burning smell is observed.
  • Abnormal noise or vibration of the unit is observed.
  • Water leaks from the indoor unit.
  • Power cord or plug becomes abnormally hot.
  • Fan speed cannot be controlled.
  • The unit stops running immediately even if it is switched on for operation.
  • The fan does not stop even if the operation is stopped. Contact your local dealer immediately for maintenance/repair.

Do not install the unit in oily and smoky areas to prevent damage to the unit.

Do not dismantle the unit for cleaning purpose to avoid injury.

Do not step onto an unstable bench when cleaning the unit to avoid injury.

Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.

Do not open window or door for long time during COOL/DRY mode operation.

Prevent water leakage by ensuring drainage pipe is: - Connected properly, - Kept clear of gutters and containers, or - Not immersed in water

This equipment must be earthed to prevent electrical shock or fi re.

After a long period of use or use with any combustible equipment, aerate the room regularly.

Prevent electric shock by switching off the power supply: - Before cleaning or servicing, - When extended non-use, or - During abnormally strong lightning activity.

After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.

CAUTION

  • To prevent malfunction or damage of the remote control:
  • Remove the batteries if the unit is not going to be used for a long period of time.
  • New batteries of the same type must be inserted following the polarity stated.

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.

English Safety precautions

Page 6 of the Panasonic CU-E12PB4EA user manual — Auto OFF/ON button
Page 6 · click to enlarge
Page 6

How to use

Panasonic CU-E12PB4EA — How to use diagram (page 6)
Fig. 5 · How to use
Panasonic CU-E12PB4EA — How to use diagram (page 6)
Fig. 6 · How to use

MODE

To select operation mode

  • AUTO - For your convenience
  • During operation mode selection the POWER indicator blinks.
  • Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT - To enjoy warm air
  • Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL - To enjoy cool air
  • To reduce power consumption during COOL mode, use curtains to screen off sunlight and outdoor heat.

DRY - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation.

POWERFUL/

QUIET To switch between powerful & quiet

QUIET POWERFUL NORMAL

POWERFUL: To reach temperature quickly

POWERFUL

Press and hold for approximately 10 seconds to show temperature setting in °C or °F.

Single • This operation stops automatically after 20 minutes.

Multi • Press the button again or turn OFF the unit to stop this operation.

QUIET: To enjoy quiet operation

Press to restore the remote control to default setting.

QUIET

  • This operation reduces airfl ow noise.

Can be activated in all modes and can be cancelled by pressing the respective button again.

Auto OFF/ON button

Panasonic CU-E12PB4EA — Auto OFF/ON button diagram (page 6)
Fig. 7 · Auto OFF/ON button

Use when remote control is misplaced or a malfunction occurs. 1. Press the button once to use in AUTO mode. 2. Press and hold the button until you hear 1 beep, then release to use in forced COOL mode. 3. Repeat step 2. Press and hold the button until you hear 2 beeps, then release to use in normal COOL mode. 4. Repeat step 3. Press and hold the button until you hear 3 beeps, then release to use in forced HEAT mode. • Press the button again to turn off.

Page 7 of the Panasonic CU-E12PB4EA user manual — AC C
Page 7 · click to enlarge
Page 7
Panasonic CU-E12PB4EA — FAN SPEED diagram (page 7)
Fig. 8
Toset the timer 2 s to t timets of ON and OF urn ON or OFF th es. 1 2 3 TIMER ON 1 2 OFFSET 3 CANCEL

FAN SPEED

To select fan speed

  • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.

AIR SWING To adjust vertical airfl ow

direction

AC C

AC C

1 Select ON or OFF timer

ExampleOFF at 22:00 • Each time pressed:
Panasonic CU-E12PB4EA — AC C diagram (page 7)
Fig. 9
  • Keeps the room ventilated.
  • In COOL/DRY mode, if AUTO is set, the louver swings up/down automatically.
  • In HEAT mode, if AUTO is set, the horizontal louver is fi xed at the predetermined position.
  • Do not adjust the louver by hand.
  • To cancel ON or OFF timer, press

or OFF to select respective or then press

CANCEL. • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing

ON or OFF to select respective or then press

  • SET .
  • The nearest timer setting will be displayed and will activate in sequence.
  • When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
  • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Quick guide.
Show 4 more labels / short text on this page
(Remote control display) · English · How to use · (Remote control display)
Page 8 of the Panasonic CU-E12PB4EA user manual — AIR FILTER
Page 8 · click to enlarge
Page 8

Cleaning instructions

  • To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Please consult authorised dealer.
  • Switch off the power supply before cleaning.
  • Do not touch the aluminium fi n, sharp parts may cause injury.
  • Do not use benzine, thinner or scouring powder.
  • Use only soap ( pH 7) or neutral household detergent.
  • Do not use water hotter than 40 °C.

Remove Air Filter

1 Press the knobs. Press the knobs.

Air Filter Installation

CLOSE OPEN OPEN CLOSE

INDOOR UNIT

Wipe the unit gently with a soft, dry cloth.

Insert the air fi lter to the tabs of the intake grille.

Panasonic CU-E12PB4EA — CLOSE OPEN OPEN CLOSE diagram (page 8)
Fig. 10

Slowly bring up the intake grille.

OPEN CLOSE CLOSE OPEN

2 Slowly pull Slowly pull down the down the intake grille. intake grille.

Remove Remove

3 Remove the air Remove the air fi lter from the fi lter from the tabs and pull it tabs and pull it downwards. downwards.

AIR FILTER

Press the knobs to the CLOSE side.

  • Vacuum, wash and dry.
  • lt is recommended to clean the air fi lter every 6 weeks.
  • Do not operate without an air fi lter.
  • Wash/rinse the air fi lter gently with water to avoid damage to the air fi lter surface.
  • Do not dry the part with a hair dryer or a stove.
  • Replace any damaged air fi lters.
  • For seasonal inspection after extended non-use
  • Checking of remote control batteries.
  • No obstruction at air inlet and air outlet vents.
  • After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: COOL: ≥8 °C HEAT: ≥14 °C
  • For extended non-use
  • Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth.
  • Turn off the power supply.
  • Remove the remote control batteries.

Knob

Page 9 of the Panasonic CU-E12PB4EA user manual — Troubleshooting
Page 9 · click to enlarge
Page 9

Troubleshooting

The following symptoms do not indicate malfunction.

SymptomCause Mist emerges from indoor unit.• Condensation effect due to cooling process. Water fl owing sound during operation.• Refrigerant fl ow inside the unit. The room has a peculiar odour.• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour. Airfl ow continues even after operation has stopped.• Extraction of remaining heat from the indoor unit (maximum 30 seconds). Operation is delayed a few minutes after restarting.• The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes. TIMER indicator is always on.• The timer setting repeats daily once set. Indoor fan stops occasionally during heating operation.• To avoid unintended cooling effect. POWER indicator blinks before the unit is switched on.• This is a preliminary step in preparation for the operation when the ON timer has been set. Cracking sound during operation.• Changes of temperature caused the expansion/ contraction of the unit.

Cleaning instructions / Troubleshooting

Check the following before calling for servicing.

SymptomCheck Operation in HEAT/COOL mode is not working effi ciently.• Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. Noisy during operation.• Check if the unit has been installed at an incline. • Close the intake grille properly. Remote control does not work. (Display is dim or transmission signal is weak.)• Insert the batte • Replace weakries correctly. batteries. The unit does not work.• Check if the cir • Check if timerscuit breaker is have been settripped. . The unit does not receive the signal from the remote control.• Make sure the • Certain fl uores transmitter. Plereceiver is not cent lights may ase consult auobstructed. interfere with signal thorised dealer. NON SERVICEABLE CRITERIAS The unit stops and the TIMER indicator TURN OFF POWER SUPPLY then please blinks. consult authorised dealer under the Use remote control to retrieve error code. following conditions: • Abnormal noise during operation. 1 Press for TI OM NER SET 2 Press until you 5 seconds hear beep sound, • Water/foreign particles have entered the 1 2 3 then write down remote control. • Water leaks from Indoor unit. 3 Press for OFF CANCEL the error code • Circuit breaker switches off frequently. 5 seconds AC RC 4 Turn the unit off • Power cord becomes unnaturally warm. to quit SET CHECK CLOCK RESET and reveal the • Switches or buttons are not functioning checking error code to authorised dealers and the TI to retrieve error TIMER ON 1 OF SETSE 2 3 F CAN AC R CHECK CLOCK RESET
  • For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.

English

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Mist emerges from indoor unit.• Condensation effect due to cooling process. p.9
Water fl owing sound during operation.• Refrigerant fl ow inside the unit. p.9
The room has a peculiar odour.• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. p.9
Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour. p.9
Airfl ow continues even after operation has stopped.• Extraction of remaining heat from the indoor unit (maximum 30 seconds). p.9
Operation is delayed a few minutes after restarting.• The delay is a protection to the unit’s compressor. p.9
Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes. p.9
TIMER indicator is always on.• The timer setting repeats daily once set. p.9
Indoor fan stops occasionally during heating operation.• To avoid unintended cooling effect. p.9
POWER indicator blinks before the unit is switched on.• This is a preliminary step in preparation for the operation when the ON timer has been set. p.9
Cracking sound during operation.• Changes of temperature caused the expansion/ contraction of the unit. p.9
Operation in HEAT/COOL mode is not working effi ciently.• Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. p.9
Noisy during operation.• Check if the unit has been installed at an incline. • Close the intake grille properly. p.9
Remote control does not work. (Display is dim or transmission signal is weak.)• Insert the batte • Replace weak p.9
The unit does not work.• Check if the cir • Check if timers p.9
The unit does not receive the signal from the remote control.• Make sure the • Certain fl uores transmitter. Ple p.9
NON SERVICEABLE CRITERIAS The unit stops and the TIMER indicator TURN OFF POWER SUPPLY then please blinks. consult authorised dealer under the Use remote control to retrieve error code. following conditions: • Abnormal noise during operation. 1 Press for TI OM NER SET 2 Press until you 5 seconds hear beep sound, • Water/foreign particles have entered the 1 2 3 then write down remote control. • Water leaks from Indoor unit. 3 Press for OFF CANCEL the error code • Circuit breaker switches off frequently. 5 seconds AC RC 4 Turn the unit off • Power cord becomes unnaturally warm. to quit SET CHECK CLOCK RESET and reveal the • Switches or buttons are not functioning checking error code to authorised dealer p.9

Ask about the Panasonic CU-E12PB4EA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic CU-E12PB4EA

Be the first to ask — other owners or our team will answer.

Original document

Panasonic CU-E12PB4EA manual PDF

80 pages·6.9 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…