Electronic touch screen programmable thermostat with wall-mounting suitable for the temperature control in household. Battery powered, with backlit monocolor display (blue) and input for external contact with whom to switch on/to switch off the programmable thermostat remotely (by telephone).
This instrument performs actions of 1B type and are intended for operating in environments Pollution degree 2 and Overvoltage Category III (EN 60730-1).
5IFJOTUSVNFOUNVTUCFJOTUBMMFECZBRVBMJGJFEQFSTPO JOTUSJDUDPNQMJBODF
XJUIUIFDPOOFDUJPOEJBHSBNT %POPUQPXFSPSDPOOFDUUIFJOTUSVNFOUJGBOZQBSUPGJUJTEBNBHFE "GUFSJOTUBMMBUJPO JOBDDFTTJCJMJUZUPUIFDPOOFDUJPOUFSNJOBMTXJUIPVU
appropriate tools must be guaranteed. 5IFJOTUSVNFOUTNVTUCFJOTUBMMFEBOEBDUJWBUFEJODPNQMJBODFXJUIDVSSFOU
Model description Touchscreen programmable thermostat batteries white

t Power supply:
– 2 alkaline batteries 1.5 V (AAA type) – battery life: 1 year – battery charge level indication – charge reserve ( for battery replacement): 1 minute t 8BMMNPVOUJOHPSUPDPWFSBHFUISFFNPEVMFJOCVJMUCPY t 5FSNJOBMT
– 3 terminals for 1.5 mm² cable section for bistable output relay 5A / 250 Vac – 2 terminals for 1.5 mm2 cable section for digital input (on/off with telephone
– On/off with hysteresis setting between 0.1 °C and 1°C – Proportional with settable band and period t 4VNNFSXJOUFSPQFSBUJOHNPEF t 8FFLMZQSPHSBNNJOH QSPHSBNTBWBJMBCMFGPSFBDIPQFSBUJOHNPEF t %BJMZSFTPMVUJPOIPVS QPTTJCJMJUZUPTFUEFMBZBDUJWBUJPOPG NJOVUFT
independent for each hour) tTFUUBCMFUFNQFSBUVSFT
– T1, T2, T3 in automatic operation – Tm in manual operation – Toff in off mode (antifreeze) t .FBTVSFEUFNQFSBUVSFEJTQMBZ¡$ t .FBTVSFNFOUQSFDJTJPO¡$¡$ t .FBTVSFEUFNQFSBUVSFSFTPMVUJPO¡$ t 4FUQPJOUSBOHF¡$ t $MPDLQSFDJTJPOTFDPOEEBZ t ,FZMPDLCZQBTTXPSE t 4VNNFSXJOUFSUJNFBVUPNBUJDDIBOHF FYDMVEBCMF t 0QFSBUJOHUFNQFSBUVSF ¡$ t 4UPSBHFUFNQFSBUVSF ¡$ t 0QFSBUJOHIVNJEJUZOPODPOEFOTJOH t 1SPUFDUJPOEFHSFF*1 t *OTVMBUJPOSFJOGPSDFEBNPOHBDDFTTJCMFQBSUT GSPOUBM BOEBMMPUIFSUFSNJOBMT
dialler) t 5FNQFSBUVSFSFHVMBUJPO


①Day of the week (DAY 1 = Monday) ②Programming menu:
: date/time and summer time setting : programs change mode (for automatic operating) : temperatures setting T1, T2. T3 : timing menu : advanced programming menu : not used: not used ③Time and minutes ④Load activation in summer mode/ cooling ⑤Manual operation activation ⑥Load activation in winter mode/heating ⑦Measured environment temperature ⑧Program on graphic for the current date (in automatic operation) ⑨Off operation ⑩Depleted battery indication ⑪,FZCPBSE UIFLFZTBSFBDUJWFPOMZJGUIFJOTUSVNFOUJTDPSSFDUMZJOTUBMMFEPO
wall-mounted base)

The keys carry out different functions on the basis of the instrument status and they will be described step by step in this user manual. Multipurpose keys are not built into the instrument, that is to say contemporary pressures of 2 or more keys. There are two types of pressure: - brief pressures, - long pressures, with duration higher than 3 seconds.
During the press of a button, the display is blue.
To clean the display use a soft, lint-free cloth, without using excess force.
"UUFOUJPOQSFTTUIFLFZTXJUIZPVSmOHFST EPOPUVTFTIBSQPCKFDUT

t The programmable thermostats of Chronos series are designed for wall-mountig .
Alternatively they can be installed to cover three-module in built box. t 5IFQSPHSBNNBCMFUIFSNPTUBUNVTUCFJOTUBMMFEBUBIFJHIUBUBCPVUNBCPWF
the floor, away from direct sunlight, away from doors, windows, heat sources, locations with excess or total lack of ventilation.

Fix the base on the wall using the
blocks of the base, as shown in the iXJSJOHEJBHSBNTw.
compartment on the back of the programmable thermostat, respecting the polarity
to the base, at first mating teeth on the higher side.

Once the instrument is mains powered, set the clock (time and date insertion). The parameters to enter are the following: seconds (only synchronisation at value 00), minutes, hours, year, month, day.
Use the keys and to increase and decrease the values and the key per confermare e passare al parametro successivo.

Once all values are set, press for a long time (3 seconds) the key to exit the menu of the clock synchronisation.
t $MPDLTFUUJOH · Day setting

At this point the programmable thermostat will begin to operate with the set default parameters (see page 31) displaying the day of the week, the time, the environment temperature and the graphic of the program on.


*GPODFNBJOTQPXFSFE OPWBMVFJT TFUXJUIJOBCPVUTFDPOET UIF programmable thermostat begins UPPQFSBUFJOPGGNPEF EJTQMBZFE XJUIUIFTZNCPM 5IFUJNFMBDL JTEJTQMBZFEXJUInBTIJOHEBTIFT @@@@
*OUIJTDPOEJUJPO UIFQSFTTVSFPGBOZLFZSFBDUJWBUFTUIFNFOVPGEBUFUJNF JOTFSUJPOGPSPUIFSTFDPOETBCPVU

With this menu it’s possible to modify the following operating parameters: - Date and time - Automatic operation programs - Automatic operation temperatures - Timings - Advanced functions.


To modify the hour and the date set:
seconds* -> minutes -> hours -> month ->day
Inside this menu it’ s also possible to modify the parameters for winter/ summer time change. The procedure is described in a detailed way in the chapter “Summer time change” on page 23.
Inside this menu it’ s also possible to modify the parameters for winter/ summer time change. The procedure is described in a detailed way in the chapter “Summer time change” on page 23.
This menu allows to modify the programmings of the automatic operation. In default status the instrument is configured to perform the program P1 from Monday
3s

to Friday and P2 on Saturday and on Sunday (the programs profile is described at the end of this manual on page 32-33). If this programming doesn’t satisfy the user needs it’ s possible to change it.
To modify the programming:

3.1. If the set program is good, move to the
next day with the keys and .
3.2. If the set program is not good, press
the key . The set program flashes: choose a different program among the 7 available programs pressing the keys and .
3.2.1. If no program exactly satisfies the
user’s needs, choose any program which best meet them and press the key to access the modification of the program profile. On field 00:00 appears while on field flashes the temperature level (T1, T2 o T3) set for that specific time (00:00).


Use the keys and to change the temperature level and the key
to move to the next hour. Set like this the desired level temperature for each hour of the day.
3.2.1.1. For each hour it’ s possible to
delay the start of th regulation of 15’, 30’ or 45’ After setting the temperature as described above, press for a long time the key to set a delay. The minutes field flashes (field 3): set with the keys and the delay and press the key to move to the next hour.
To modify the 3 temperatures of automatic operation:


and and press the key to move to the modification of T2.
and and press the key to move to the modification ofi T3.
and and press the key to go back to the page of T1 temperature.
or wait for the time-out expiration (30 seconds about).

This menu allows the setting of a timing on the current operating mode, expressed in hours and days.
For further information about timings, see the chapter “Timings: what they are” on page 27).
For further information about timings, see the chapter “Timings: what they are” on page 27).
To set a timing:

Timing setting

If a timing is active, the display shows the symbol . To interrupt a timing, access again the menu and set the value 00.
With the ADV menu it’s possible to modify the following operation parameters:
- operating mode (heating or cooling) - regulation type (on-off or proportional) - parameters relative to regulation type - antifreeze temperature - password for key lock - system operation hours.
To access the menu ADV:

This parameter allows to specify the operating mode of the programmable thermostat, between winter-heating ( ) and summer-cooling ( ).
For further information about the operating mode see the chapter “Regulation types” on page 25.
3FHVMBUJPOUZQF (only for heating mode)
For heating mode it’s possible to choose between on/off regulation (Reg 0) or proportional (rEg P).
For further information about regulation type see the chapter “Regulation types” on page 25.
Operating mode

In case of POPGG regulation the only parameter to set is the hysteresis (dIF), which can have values between 0.1°C e 1°C.
In case of proportional regulation the parameters to set are the regulation band (bnd) e il periodo di regolazione (PEr).
For further information about how to choose these values see the chapter “Regulation types” on page 25. But remember that the preset settings are suitable for the most part of the situations: to change these settings only if it’s really necessary.
For further information about how to choose these values see the chapter “Regulation types” on page 25. But remember that the preset settings are suitable for the most part of the situations: to change these settings only if it’s really necessary.
"OUJGSFF[FUFNQFSBUVSF (only for heating mode)
For the heating mode it’s possible to set a safety temperature (antifreeze temperature – 0ff) to maintain also if the programmable thermostat is switched off. It’s possible to choose a value between 1°C and 10°C. It’s also possible to deactivate the antifreeze function pressing the key until the display shows “_-.-”. In this case, if the programmable thermostat is switched off, no safety temperature is maintained.
It’s possible to set a key lock if the programmable thermostat is installed in public places or however if you want to prevent anyone from modifying the operation parameters.
To set a password, enter on field PAs a value between 001 and 999. To deactivate the password press the key until “__._” appears.
When the keyboard is locked, the thermostat performs all its functions using the set regulation parameters.
Regulation parameters

If the key lock is active and one key is pressed, the display shows for a few seconds the writing bLoc with flashing dashes: enter the password to unlock the keyboard, which will be locked for 30 seconds from the last pressure.
This page shows the total number of hours of the system operation (relais ON) for the current mode (indicated by the icons o ). The hour meter has got 4 digits and it’s resettable pressing for a long time the key until 0000 appears.

During manual operation the instrument performs as a normal thermostat, adjusting on the basis of the Tm temperature (manual setpoint), independently from the day and the time where it is. The manual operation is signalled with the switch on of the symbol on field .
To move from the automatic operation to the manual one:
If you want to change the setpoint (Tm) press the key and repeat the points 2 and 3.
To go back to the automatic operation press for a long time the key (about 3 seconds).


In off mode the instrument doesn’t perform any regulation (*) but it continues to display the day, the time and the measured temperature.

(*) When in heating / winter mode the instrument maintains a minimum temperature - Toff antifreeze temperature - to avoid the freezing of the systems where the instrument is installed. Toff can have values between 1°C and 10°C or it can be completely shut down; in this last case the saving of minimum temperature is not guaranteed. The set default Toff is 6°C but it’s possible to modify this value entering the ADV menu (see “Antifreeze temperature” page 18).
To switch the instrument off press the key until the symbol is displayed (field ).
To reactivate the regulation, switching back to the operating (automatic or manual) which is before the switching off, press the key for about 3 seconds.


Chronos has got an input for the connection to a clean contact to whom to connect for example a telephone dialler to switch on or to switch off remotely the programmable thermostat with their own telephone. The contact can have one of these two positions:
- open Æ normal operation (according to the settings) - closed Æ programmable thermostat in off mode
Remotely off status is displayed with the fl ash of the symbol on fi eld to differentiate it from the keyboard off statu ( fi xed on fi eld ).

Chronos has got a backlight of blue colour, which is activated only inside any menu of programming or if any key is pressed. In normal operating status the backlight results off. This behaviour is not modifiable.
It’s possible to display the measured values of minimum and maximum temperature. To display these values press the key (maximum value Hi) or (minimum value L0).
During the display it’s possible the resetting of these values pressing the key until 3 dashes appear in place of the temperature.
Summer time is the convention to step up of one hour the dials of the clocks during the summ er period in order to prolong the lighting time in the late afternoon to the loss of the early morning. In European countries summer time starts the last Sunday of march and ends the last Sunday of october.
The programmable thermostat manages the summer/winter time change as follows: - increasing of one hour to move from winter time to summer time - decreasing of one hour to move from summer time to winter time
In off status the instrument is configured to move from summer time the last Sunday of march at 02:00 o’ clock to go back to winter time the last Sunday of October at 03:00 o’ clock in accordance with Europe convention. However it’s possible to deactivate the automatic time change or to change the date and the hour of the time change.

To change settings:
2. press the key to access the time and date modification. At this point, during the modification of any parameter (seconds, minutes, hour, year, month or day) press for a long time the key until the display shows the writing Aut0 appears on field . 3. Choose with the key and the automatic time change activation (Aut0 0n) or its deactivation (Aut0 0FF) and confirm with the key . 4. If 0FF we go back to the date/time change; if 0n the current setting for the passage to summer time is displayed (indicated with the symbol ). In the example: a. the Sunday (7) of the last week (LA) of

march (03) at 2 o’ clock (02) b. b. if it’s necessary change the parameters
with the keys and and move to the next parameter with the key . The sequence requires the insertion of: i. day (1…7) of the week ii. the week of the month (first, second,
third, fourth, last – LA) iii. the month (1…12) iv. the hour 5. press the key the current setting for the passage to the winter time is displayed (indicated with the symbol ). In the example: a. the Sunday (7) of the last week (LA) of
october (10) at 3 o’ clock (03) b. if it’s necessary change the parameters
with the keys and and move to the next parameter with the key . The sequence requires the insertion of: i. day (1…7) of the week ii. the week of the month (first, second,
third, fourth, last – LA)

iii. the month (1…12) iv. the hour 6. Once all parameters are set, to exit and to go back to the programming menu, press for a short time the key . To exit and to go back to the normal operation press for a long time the key or wait for the time-out expiration (30 seconds about).
The Chronos has got two types of regulation:
During on/off regulation the programmable thermostat measures once a minute the environment temperature and it carries out the regulation on the basis of the following logic:
heating mode cooling mode
SET-DIFF SET relay OFF
SET+DIFF SET relay OFF
where SET represents the setpoint and DIFF the hysteresis (useful to avoid continuous switches on/switches off dangerous for the system in proximity to the reaching of the setpoint).
In heating mode, the on/off regulation is available and also the proportional regulation which in some systems allows a more precise regulation to obtain a constant temperature.
This regulation requires to specify two parameters: t UIFCBOE XIJDISFQSFTFOUTUIFUFNQFSBUVSFWBMVFTXJUIXIPNUPQFSGPSNUIF
proportional regulation. The band is centered on the setpoint and it can have values between 0.5°C and 5°C; outside these values the heating will be always on

JGTFUQPJOUCBOE FOWJSPONFOUUFNQFSBUVSF PSBMXBZTPGG JGTFUQPJOU CBOE environment temperature).
BDUJWBUJPOUJNF EFBDUJWBUJPOUJNFPGIFBUJOH BOEJUDBOIBWFWBMVFTPG PS 30 minutes.
During the operating, at the beginning of the regulation period, the instrument measures the environment temperature and it compares it with the programmed setpoint; on the basis of this difference the activation time is calculated (and consequently the deactivation time). The more the measured temperature is next to the setpoint value – band, the more the activation time will be predominant in comparison with the deactivation time; on the contrary, the more the measured temperature is next UPUIFTFUQPJOUWBMVF CBOE UIFNPSFUIFEFBDUJWBUJPOUJNFXJMMCFQSFEPNJOBOUJO comparison with the activation time). Once regulation period is passed, the instrument compares again the environment temperature with the setpoint and it updates the activation and deactivation times for the new period.
The result of the proportional regulation is subordinated to the correct selection of the parameters.
Select the value of the regulation type as follows:
t GPSMPXUIFSNBMJOFSUJBTZTUFNT GBODPJM t GPSNFEJVNUIFSNBMJOFSUJBTZTUFNT BMVNJOJVNSBEJBUPST t GPSNFEJVNUIFSNBMJOFSUJBTZTUFNT BMVNJOJVNSBEJBUPST
Select the regulation band value as follows:
t CSPBECBOE ¡$ GPSTZTUFNTXJUIIJHIUIFSNBMHSBEJFOU t OBSSPXCBOE ¡$ GPSTZTUFNTXJUIMPXUIFSNBMHSBEJFOU
"UUFOUJPOJOEFGBVMUTUBUVTUIFJOTUSVNFOUJTDPOmHVSFEUPPQFSBUFJOPO PGGXJUIIZTUFSFTJTTFUBU¡$5IJTDPOmHVSBUJPOJTTVJUBCMFGPSUIFNPTU QBSUPGUIFTJUVBUJPOTBOEGPSUIJTSFBTPOJUTBEWJTBCMFUPNPEJGZJUPOMZJO particular situations.
To modify the regulation type, hysteresis values (on/off regulation), band and period (proportional regulation) see “Regulation parameters” at page 18). To modify the regulation type, hysteresis values (on/off regulation), band and period (proportional regulation) see “Regulation parameters” at page 18).
t 5IFSFHVMBUJPOQFSJPEXIJDISFQSFTFOUTUIFEVSBUJPOPGUIFSFHVMBUJPODZDMF

The instrument performs a regulation of emergency if an error occurs during the reading of the probe or in case of time loss.
In case of probe error, if the antifreeze function is not deactivated, the instrument activates the load for 10 minutes every 4 hours. The display shows the writing Err on field .
In case of time loss (because of depleted batteries or blackout of a duration higher than the charge reserve) the instrument restarts from the off mode, adjusting on the basis of the antifreeze temperature, if it hasn’t been deactivated before. Reset date/ time to go back to the normal operation (programs modifications and settings remain memorized).
Timings allow to maintain the current operation (automatic, manual, off) for a certain period (times or days) and once passed the programmable thermostat changes the operating mode, as explained below.
The timed operations are the following:
If in automatic status you set a timing, such off status will be maintained until the end of the timing; operation will then switched to off mode.


If in manual status you set a timing, such off status will be maintained until the end of the timing; operation will then switched to automatic mode.
Timed automatic · Timed manual




If in off status you set a timing, such off status will be maintained until the end of the timing; operation will then switched to the one active before the deactivation (automatic or manual).


If you set a timing, the display shows the symbol .
- time/ date modifi cation (modifi cation of the summer time change included) - manual modifi cation of the operating mode - switching of digital input (only for battery models) - change of the operating logic from winter to summer (or viceversa)
To set a timing, see chapter “Timing setting” at page 15.

If you want to erase all performed settings and to recharge the default values, proceed as follows:
Default values are indicated on page 31 of this manual.
Chronos signals the status of depleted batteries switching on the symbol (field ) and making the display to flash. In this status the regulation is always guaranteed, but it’s advisable to replace the batteries as soon as possible! (*)
If the charge level of batteries further decreases, the programmable thermostat enters into less consumption mode, it switches off the display and it doesn’t perform any regulation.
(*) Remove the depleted batteries and replace them with the new ones in a maximum time of one minute (charge reserve) to avoid to lose the settings of date and time (the performed programmings on the contrary remain memorized even if this limit is surpassed).
"UUFOUJPOBGUFSCBUUFSJFTSFQMBDFNFOU UIFEJTQMBZXJMMTXJUDIPOXJUIJO seconds at max.
JOSFMBUJPOUPUIFEJTQPTBMPGIB[BSEPVTXBTUF.

Compliance with Community Directives 2006/95/EC (Low voltage) 2004/108/EC (E.M.C.) is declared in reference to the harmonized standard:
&/ &/

Parameter min max step EFGBVMU
winter manual setpoint 2.0°C 35.0°C 0.1°C 21°C
summer manual setpoint 2.0°C 35.0°C 0.1°C 25°C
T1 winter 2.0°C T2 0.1°C 15.0°C
T2 winter T1 T3 0.1°C 18.0°C
T3 winter T2 35.0°C 0.1°C 21.0°C
T2 summer 10.0°C T3 0.1°C 23.0°C
T3 summer T2 35.0°C 0.1°C 25.0°C
antifreeze temperature 1.0°C 10.0°C 0.1°C 6.0°C
operating mode winter summer - winter
regulation type ON/OFF PROP - ON/OFF
ON/OFF hysteresis 0.1°C 1.0°C 0.1°C 0.3°C
proportional band 0.5°C 5.0°C 0.1°C 0.5°C
proportional period 10’ 30’ 10’ 10’
password 0 999 1 000 (deactivated)
winter hour meter 0 1 0
summer hour meter 0 1 0
summer hour meter, enable ON OFF - ON
03:00
activation delay 0’ 45’ 15’ 0’
timed operations 0h 99d 1h 0h
winter/summer time change

1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
T2
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 · 1

1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
T2
1 2 3 4 5 8 11 12 13 14 15 18 21 22 23
1 · 1





ORBIS TECNOLOGÍA ELÉCTRICA, S.A.