be used as the source to create
final, printed pieces of the file it
represents. Rather, it is a low
resolution visual reference only
containing relevant information
regarding the file (e.g., color, text
and image placement, etc.)




No-Watering Days and Times It’s easy to prevent watering on one or more days of the week or during specific periods of the day. This comes in handy if watering restrictions are imposed in your area.
Easy-to-Read Back-Lit LCD Display The timer’s back-lit blue LCD display screen is easy to read under any lighting conditions.
Choice of Five Languages You can easily set the LCD display to read in any of five languages: English, Spanish, French, German or Italian.
Docking Port This timer has been designed for convenience and “armchair” programming. The timer’s docking port is mounted on a wall and all wires are connected to it. The main timer unit can be easily and quickly slid on and off the docking port, allowing you to take the timer virtually anywhere to create or change watering programs.
Water Budgeting This convenient feature provides a quick, easy way to increase or decrease the watering durations of all stations in both programs to match seasonal watering needs. You won’t have to adjust each station’s watering time individually.
Remote Control Capabilities (Not included on all models) This timer can be controlled by the included remote control device via a radio frequency (RF) receiver and antennae, both of which are built into the timer. The remote control device allows you to turn stations on and off on the spot and to perform programming tasks from anywhere within range. The 433 megahertz remote frequency is approved for use in the United States, Canada, Europe and Australia, and permits an effective line-of-sight range of 300 feet (reduced to 200 feet with obstructions).
Rain Sensor (Optional) An optional rain sensor can be purchased separately to prevent programmed watering for a period of time after rain falls (determined by the amount of rain and how quickly the sensors dry out). If your unit is RF capable then you can use a wireless sensor. Otherwise a hard-wired sensor can be used.
Digital Display with Text Messaging A large LCD (Liquid Crystal Display) shows the time of day and indicates many of the programming settings. Interactive text messaging simplifies programming and current sprinkler timer status. (See Figure 1)
Programming Information Stored Safely in Non-Volatile Memory All programming information for Program A and Program B is stored indefinitely in the timer’s non-volatile memory (EEPROM) and internal memory. This high-end feature means your programming won’t be lost or erased if the power and batteries go out.

Programming Buttons These nine buttons are used for programming and other operations:
Selection Dial This dial is used for programming, reviewing and operating the sprinkler timer.
Rain Sensor Bypass Switch In Active position the controller will monitor the rain sensor, in Bypass position the controller will ignore the rain sensor. (This switch is for hard wired sensors only and does not effect wireless rain sensors - sensors sold separately).
ACTIVE BYPASS
A T
E R
I N
G
P E
R I
O
D
N
O
W
Y
D
A
About This Manual
We have added the following features to this manual to assist you:
A RF Sync (only on remote control model) Allows the timer to synchronize with a new remote or wire less sensor.
b Rain Delay Push this button once while in AUTO to access the rain delay option. NOTE: Pressing this button will access the Language and No Watering Period options while in those respective dial positions.
You can program this sprinkler timer in just a few basic steps. Before you begin programming, it is important to:
c Reset (pin hole) Resets the timer to its factory settings.
d Increase e Decrease f Enter g Next h Clear i Manual

If no programming occurs after the RESET button has been pressed and the dial is left in the AUTO position the timer will assume a default program mode. In default mode, the timer will automatically water each station for 10 minutes, beginning at 5 a.m. each day.
The display will show “LOW BATTERY” when it is time to replace the batteries.
If this is the first time the timer has been programmed, press the small recessed RESET button.
If this is the first time the sprinkler timer has been pro- grammed, you should press the small recessed button labeled RESET (located under the RAIN DELAY button). You will prob ably need a pen, pencil or similarly small object to push it.
Do not press the RESET button again unless you want to com pletely remove all your programming, including time and date.

Determine a Watering Plan See page 20 for instructions.
G
R I
O
D
E R
A T
P E
W
O
Y
A
D
N
/ ·

CLEAR button or by selecting another watering day mode. The water drop will disappear.
Set to Water - Interval
Set to Water - Days of the Week:
Set to Water - Odd Days:
Set to Water - Even Days:
There may be one or more days of the week when you never want to have the water turn on, regardless of what the program

says. (For example, in some water districts, watering is prohibited on certain days.) To cancel programmed watering on specific days of the week, follow these steps:
To Prevent Watering During a Particular Period of the Day:
Water Budgeting is a quick way to adjust your set durations (10 to 200%) based on seasonal requirements.
There may be a time of the day when you never want the water to come on, regardless of what the program calls for. (Perhaps your community has banned watering during certain periods of the day, or you don’t want your children to get wet going to school.) Here’s what to do:

duration to 20 minutes, and a setting of 10% will decrease a 10 minute duration to 1 minute.
Each station with a set duration will water in sequence. To quickly advance from one station to the next press NEXT .
With the “TEST ALL” function, you can easily test all the water ing stations by turning them on in sequence for one minute each.
To abort this process before the manual watering is finished, press CLEAR . Otherwise, the timer will automatically exit the “MANUAL ALL” mode after all stations have run.
This will allow you to water only those stations with set dura tions in Program A.
Each watering station will turn on for one minute, in sequence. To abort this process before the test is finished, press the CLEAR button. To advance quickly from one station to the next press NEXT . Otherwise, the timer will automati cally exit the “TEST ALL” mode after all stations have run for one minute.
Each station will water, in sequence, one after another, for the same duration specified in Program A. To quickly advance from one station to the next press NEXT .
With the “MANUAL ALL” function, you can manually turn on the watering stations at any time.
To abort this process before the manual watering is finished, press CLEAR . Otherwise, the timer will automatically exit the “A – MANUAL ALL” mode after all Program A stations have run.

This will allow you to water only those stations with set dura tions in Program B.
To abort this process before the manual watering is finished, press CLEAR . Otherwise, the timer will automatically exit the “MANUAL – STATION” mode after the selected station has run.
You can press the RAIN DELAY button to stop all programmed watering from taking place for a certain number of hours or days (for instance, after a rain storm).
Each station will water, in sequence, one after another, for the same duration specified in Program B. To quickly advance from one station to the next press NEXT .
To abort this process before the manual watering is finished, tpress CLEAR . Otherwise, the timer will automatically exit the “B – MANUAL ALL” mode after all Program B stations have run.
This will allow you to water a single station at a time.
The timer will revert to the programmed schedule at the expira tion of the rain delay period. To return to the programmed schedule before the expiration of the rain delay period, press the CLEAR button.

the current station to the next station in the cycle. This can be done during scheduled, manual, or remote actuated watering.
To Water All Stations:
To Water One Station:
The remote device provided with your timer is already synchro nized to your timer. If the remote is not functioning properly or if you are adding a new remote or RF sensor to your system do the following:
To Water More Than One Specific Station:

To Cancel Remote Control Device Operation and Return Control to Timer:
An optional rain-freeze sensor can be purchased separately to prevent programmed watering for a specified period of time after rain falls or during periods when temperatures fall below a specified temperature. The sensor has settings for RAIN, OFF and RAIN/FREEZE. Please refer to the manual that accompanies the rain-freeze sensor for installation and programming instruc tions.
ACTIVE BYPASS
G
O
D
A T
E R
W
P E
R I
Y
O
N
A
D
Section 6: Installing Indoor Mount Sprinkler Timer and Remote Control Device Sleeve
Slide the Timer off the Docking Port
SENSOR COM PUMP 1 2 3 4 5 6 7 8 9 10 11 12 24 VAC
/

the two power leads from the transformer into each terminal socket using the phillips screwdriver to depress the terminal button (this allows for wire insertion or removal).
A. Wire the Electric Valves
1 2 3 4 5 6 7 8 9 10 11 12 24 VAC
Terminal Button

C. Connect Pump Start and Master Valve
B. Connect Valve Wires to the Sprinkler Timer
This timer allows a master valve or pump start relay to oper ate whenever a station is on.
From the pump start relay (or master valve); connect one wire to the “PUMP” socket and the other wire to the “COM” socket.
Once all connections to the docking port are made, you may slide the timer back onto the docking port.
SENSOR COM PUMP 1 2 3 4 5 6 7 8 9 10 11 12 24 VAC
Common Wire · Terminal Button · Station Valves

Internal Auto-Resetting Electronic Circuit Breaker
The sprinkler timer is equipped with an internal electronic self-resetting circuit breaker.
Possible causes of a circuit breaker tripping:
Smart-Scan® Diagnostic Fault Sensing
A diagnostic fault sensor will automatically scan for the presence of a faulty solenoid or wiring short in a valve during each watering sequence. If a faulty station is detected, the sprinkler timer will move to the next working station. Smart- Scan® also detects faulty wiring for the Pump or Master Control. Upon detection watering cycle is discontinued.
Whenever one of these conditions occurs, the electronic circuit breaker may trip, causing the station output from the sprinkler timer to be halted momentarily. The batteries will continue to activate the LCD. After a few moments, the sprinkler timer will automatically retest the circuit to see if the condition has stopped. If so, the circuit breaker will reset itself.
Fault Notification · Correcting the Fault

The time the program begins watering the cycle A valve that prohibits water from reaching station valves A feature that allows a program to be operated multiple times on the same day A schedule for a group of stations that determines the date and time for watering
Program (A or B)
A feature that prevents the sprinkler timer from running it's scheduled watering program for a specific duration The electrical part on a sprinkler (irrigation) valve that opens and closes the valve A device that is responsible for turning an automatic irrigation system on and off
When a start time is scheduled to begin before the previous cycle has completed An area where the watering (irrigation) is all controlled by a single control valve The connection point on the docking port where a wire is inserted See “Program (A or B)” Specific days and/or times that local municipalities prohibit watering Used in conjunction with sprinkler timers – a convenient way to deliver water to lawns, plants and gardens
See “Station (Watering Station)”
Your timer allows you to set up to six different watering cycle start times for Program A or Program B. You cannot set a cycle start time for each station. Stations can be assigned to either Program A or Program B. Stations assigned to a program will turn on sequentially according to the cycle start times assigned.
Your timer has two programs: Program A and Program B. The dual program capability allows you to assign certain water ing stations to Program A and others to Program B. There are various reasons why you would want to do so. For example, you might want to assign the stations that water the garden and flower beds to Program A and those that water the lawn areas of your yard to Program B. That way, you can set Program A to water the garden beds every day, and set Program B to water the lawn every second or third day.
To help you visualize how best to program your timer, it might be helpful to make a watering plan on paper. This will help you establish the days, times and durations to water each station.

Based on the preceding information your water program may look like this:
5:00 AM
A
B
6:45 AM
B
9:00 PM

Symptom Possible Causes of Problems
One or more stations do not turn on
Replace solenoid Repair wire and check connections Turn flow control stem counter-clockwise until desired flow is achieved Check to make sure the station in question is set to water with a program
Stations turn on when they are not supposed to
Install a pressure reducer Reduce the number of start times for that program Set station duration to 0 for suspect program
One station is stuck on and will not shut off
Check that valve is not installed backwards Remove dirt or debris from valve Replace diaphragm Check connections and outlet if NO A/C power persists replace transformer Check Start Time and Watering Days Turn dial to AUTO
All stations do not turn on
Timer will not power up
Check connections and outlet if NO A/C power persists replace transformer Push down timer on docking port until back light turns on.
Stations continue to turn on and off when they are not programmed to
Reduce the number of start times for that program Install pressure reducer Check wiring or replace solenoid
Correction

Before returning this sprinkler timer to the store, contact Orbit® Technical Service at: 1-800-488-6156, 1-801-299-5555.
The sprinkler timer is tested to UL-1951 (Models 57922, 57926, 91922, 91926, 94922, 94926) standard and is ETL® listed. Appropriate international models are CSA® and CE® approved.
Orbit® Irrigation Limited Six-Year Warranty
Orbit® Irrigation Products, Inc. warrants to its customers that its products will be free from defects in materials and workman ship for a period of six years from the date of purchase.
We will replace, free of charge, the defective part or parts found to be defective under normal use and service for a period of up to six years after purchase (proof of purchase required).
We reserve the right to inspect the defective part prior to replacement. Orbit® Irrigation Products, Inc. will not be re sponsible for consequential or incidental cost or damage caused by the product failure. Orbit® liability under this warranty is limited solely to the replacement or repair of defective parts.
To exercise your warranty, return the unit to your dealer with a copy of the sales receipt.
Orbit® Irrigation Products, Inc. North Salt Lake, UT 84054 USA www.orbitonline.com | 1-800-488-6156
SAFETY OF CHILDREN: The controller is not intended for use by young children or infirm person without supervision. Young children should be supervised to ensure they do not play with controller. © 2007 Orbit® Irrigation Products, Inc. All rights reserved. All trade names are registered trademarks of respective manufacturers listed.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| One or more stations do not turn on | 1. Faulty Solenoid | Replace solenoid | p.19 |
| One or more stations do not turn on | 2. Wire broken or not connected | Repair wire and check connections | p.19 |
| One or more stations do not turn on | 3. Flow control stem screwed down, shutting valve off | Turn flow control stem counter-clockwise until desired flow is achieved | p.19 |
| One or more stations do not turn on | 4. Programming is incorrect | Check to make sure the station in question is set to water with a program | p.19 |
| Stations turn on when they are not supposed to | 1. Water pressure is too high | Install a pressure reducer | p.19 |
| Stations turn on when they are not supposed to | 2. More than one start time is programmed | Reduce the number of start times for that program | p.19 |
| Stations turn on when they are not supposed to | 3. Stations are set to water with both programs | Set station duration to 0 for suspect program | p.19 |
| One station is stuck on and will not shut off | 1. Faulty valve | Check that valve is not installed backwards | p.19 |
| One station is stuck on and will not shut off | 2. Particles of dirt or debris stuck in valve | Remove dirt or debris from valve | p.19 |
| One station is stuck on and will not shut off | 3. Valve diaphragm faulty | Replace diaphragm | p.19 |
| All stations do not turn on | 1. Transformer is defective or is not connected correctly | Check connections and outlet if NO A/C power persists replace transformer | p.19 |
| All stations do not turn on | 2. Programming is incorrect | Check Start Time and Watering Days | p.19 |
| All stations do not turn on | 3. Timer is in OFF mode | Turn dial to AUTO | p.19 |
| Timer will not power up | 1. Transformer is defective or is not connected correctly | Check connections and outlet if NO A/C power persists replace transformer | p.19 |
| Timer will not power up | 2. Timer is not all the way down on the docking port | Push down timer on docking port until back light turns on. | p.19 |
| Stations continue to turn on and off when they are not programmed to | 1. More than one start time is programmed with overlapping schedules | Reduce the number of start times for that program | p.19 |
| Stations continue to turn on and off when they are not programmed to | 2. Excessive pressure | Install pressure reducer | p.19 |
| Persistant Fault | 1. Short in wiring or solenoids | Check wiring or replace solenoid | p.19 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.