ENGLISH CONTENTS 1. Safety instructions 17 2. Technical specifications 18 3. Preparation for starting 19 4. Start the generating set 21 5. Operate the generating Set 21 6. Load 22 7. Stop the generating set 24 8. Periodic checks and service 24 9. Long-term storage 28 10. Troubleshooting and remedy 29 ATTENTION Before using your LOAD-UP generator, first read this manual thoroughly, so that accidents can be prevented. GENERAL Having bought the LOAD-UP generator, you have become the owner of a high quality, reliable machine. Using it properly and maintaining it regularly, the generator will carry out heavy jobs for years to come. In this operation manual you will find use and maintenance prescriptions. Before using the generator, read this manual first and be sure that others have read it as well and have taken the necessary precautions. This generator has been designed and intended for generating electricity. The appliance must be used only for the purpose for which it was specifically designed. All other uses are to be considered incorrect and therefore unreasonable. The manufacturer cannot be held responsible for any damage resulting from improper, incorrect or unreasonable use. 1. SAFETY INSTRUCTIONS Working with generators is not without danger. To reduce this danger as much as possible, we have drawn up a number of safety measures. Always follow up these directives and always be aware of what you are doing. In this way many accidents can be avoided.

system will be heated during operation and remain hot immediately after stopping the engine.

Generator 75050/1: GENERATOR DATA Rated frequency (Hz) 50 Rated power (kW) 5 Rated voltage (AC) (V) 230 Rated current (AC) (A) 21,7 Rated revolution speed (rpm) 3000 Phases single Power factor (cosø) 1 Excitation mode controlled silicon self excitation constant voltage DC output 12 V/8,3A Operation mode 12 hours continuous running Structure mode Hand cart type Coupling method Transmission rigid connection Gross weight (kg) 171 Overall dimensions (LxWxH mm) 930 x 515 x 755 MOTOR DATA Type 4-stroke, single cylinder, direct injection diesel engine Continual output (kW/rpm) 5,7/3000 Max. power (kW/HP/rpm) 6,3/8,6/3300 Bore x stroke (mm) 86 x 72 Displacement (l) 0,418 Cooling system Forced air cooling Lubrication system Pressure splashing Lube oil capacity (l) 1.65 Starting system Electric starter Fuel oil Diesel oil Fuel tank volume (l) 16 Low oil alarm system Will switch off the engine Sound pressure level dB(A)/7 m 68



BATTERY Check the battery electrolyte level every month. Refill the distelled water until the upper limits if the electrolyte dropped to the lower limits. Caution: If the electrolyte level is too low, the engine may fail to start because there is not sufficient power. On the other side, if the electrolyte level is too high, the fluid will corrode the surrounding parts.Do keep the electrolyte level between the upper and lower limits.
5.2 Checks during the running 1. Whether there is abnormal sound or vibration; 2. Whether the engine misfires or runs rough; 3. Check the color of the exhaust. (Is it black or too white?) If you notice any of the above-mentioned phenomenon happened, stop the engine and find out the fault cause or contact with our agents.


6.3 Electric appliance particularly moto-driven equipment will produce very high current while starting, below the table provides the reference for connecting these apparatus to the generating set.



The generating set has been stored more than 10 days.

8.1 Replace engine oil Remove the oil filter cap. Remove the drain plug and drain the old oil while the engine is still warm. The plug is located on the bottom of the cylinder block. Tighten the drain plug and refill with the recommended oil. 8.2 Clean the engine oil filter Cleaning time: Every 6 months or 500 hours. Replace if necessary. 8.3 Replace the air cleaner element. Do not clean the aircleaner with detergent. Replace time: Every 6 months or 500 hours. Caution: • Never run the engine without the element or with a defective element. 8.4 Clean and replace fuel oil filter The fuel oil filter also has to be cleaned regularly to insure maximum engine output. Cleaning time: Every 6 months or 500 hours. Replace time: Every year or 1000 hours. 1.Drain out the fuel from the fuel tank. 2. Drain out the fuel from the fuel tank. Screw off the small screw of the fuel cock and pull out the filter from the filler port. 3. Wash the filter thoroughly with diesel fuel. Loosen the fastening nut, bottom cover and delivery discs for cleaning the deposit carbon.


1 Operate the engine for about 3 minutes and then stop. 2 Stop the engine. Drain the engine oil while the engine is still warm and fill with fresh oil. 3 Remove the screw plug on the cylinder head cover and refill 2cc engine oil, then put the plug in place. 4 Turn the engine 2-3 seconds with the decompression lever set at the non-compression position, and the starting key at the "START" position.( (Do not start the engine.) 5 Wipe off the oil and dirt from the engine and store in a dry place.




- - - - - - - -

EG-verklaring van overeenstemming Wij, Load Up, postbus 114, 8900 AC Leeuwarden, Nederland, verklaren geheel onder eigen verantwoordelijkheid dat de producten Generatoren 75050/1 waarop deze verklaring betrekking heeft, in overeenstemming zijn met de volgende normen : EN 60335-1 en EN 60335-2-29 en de richtlijnen : de EMC richtlijn 89/336/EG, de CE marking richtlijn 93/68/EG, de richtlijn 72/23/EG en de richtlijn 2000/14/EG Nederland, Leeuwarden, 17 februari 2006 EG-Konformitätserklärung Wir, Load Up, Postfach 114, 8900 AC, L eeuwarden, Niederlande, erklären ganz auf eigene Verantwortung, dass die Produkte Generatore 75050/1 auf das sich diese Erklärung bezieht mit den Normen EN 60335-1 und EN 60335-2-29 übereinstimmen und den Richtlinien: EMC Richtlinie 89/336/EC, Richtlinie CE marking 93/68/EC, der Richtlinie 72/23/EC und der Richtlinie 2000/14/EC Niederlande, Leeuwarden, den 17. Februar 2006 EC-declaration of conformity We, Load Up, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the products Generators 75050/1 to which this declaration refers, comply with the norms EN 60335-1 and EN 60335-2-29 and the directives: EMC directive 89/336/EC, CE marking directive 93/68/EC, the directive 72/23/EC and the directive 2000/14/EC The Netherlands, Leeuwarden, 17th February 2006 Déclaration CE de conformité Nous, Load Up, P.O. Box 114, 8900 AC Leeuwarden, Pays Bas, déclarons entièrement sous notre propre responsabilité que les produits Générateurs 75050/1 auquel cette déclaration a trait sont conformes aux normes EN 60335-1 et EN 60335-2-29 et aux directives: la directive EMC 89/336/EC, la directive CE marking 93/68/EC, la directive 72/23/EC et la directive 2000/14/EC Pays Bas, Leeuwarden, le 17 février 2006 Declaracíon CE de conformidad Load Up, C.P. 114, 8900 AC Leeuwarden, Paises Bajos, declaramos bajo nuestra exclusiva responsabilidad la conformidad del producto Generador 75050/1 al que se refiere esta declaración, con las disposiciones de la Directiva Directivas 89/336 CE, 93/68 CE, 72/23 CE y 2000/14/CE Para lo cual se han seguido las normas EN 60335-1 y EN 60335-2-29 Paises Bajos, Leeuwarden, el 17 de febrero 2006
E.J. de Vries Directeur/Geschäftsführer/Managing director/dDirecteur général/Director gerente

Versie 08.2006
75050/1