  • Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location.
  • Wipe up spilled gasoline at once.
  • Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building’s electrical system.
  • Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage.
  • Place the generator at least 1 m away from buildings or other equipment during operation.
  • Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
  • When operating the machine link with earth to prevent an electric shock.
  • Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions.
  • Keep children and pets away from the generator when it is in operation.
  • Keep away from rotating parts while the generator is running.
  • The generator is a potential source of electrical shocks when misused; do not operate with wet hands.
  • Do not operate the generator in rain or snow and do not let it get wet.
  • WARNING: the warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
  • Only those persons who are aware of how to use the generator by having read this manual, should use the machine. Injudicious use may cause danger. 3. PRE-OPERATION CHECK Fuel tank capacity: 4 l.

Use oil-mixed gasoline. If not, engine will be overheated. Do not fill above fuel filter top. How to make mixed gasoline. Gasoline and oil mixing ratio; 50:1 or 40:1 (summer) Use fuel tank cap to measure oil. Shake fuel tank before starting the engine.

Page 3 of the Load Up 75016 user manual
Page 3 · click to enlarge
Page 3
4. STARTING THE ENGINE Before starting, do not connect electric apparatus. 1. Shake fuel tank before starting the engine. 2. Turn chock lever to "1".
Page 4 of the Load Up 75016 user manual
Page 4 · click to enlarge
Page 4
3. Turn engine switch to "ON". 4. Pull slowly on recoil starter until engaged, then pull it briskly. 5. Return chock lever. 5. STOPPING THE ENGINE 1. Before stopping, turn off electric apparatus. 2. Turn engine switch to "STOP".
Page 5 of the Load Up 75016 user manual
Page 5 · click to enlarge
Page 5
6. CONNECTION 1. Wind lead 2 or 3 turns around handle. 2. Start engine. 3. Plug into AC socket. SAFETY DEVICES Press to reset AC protector. Reduce load within rated output if AC protector turns off. 1 = “ON” 2 = “OFF” 7. MAINTENANCE Regular maintenance of your generator will increase durability and reliability!
Page 6 of the Load Up 75016 user manual
Page 6 · click to enlarge
Page 6

Item Remarks Every 50 hours or every month

Every 150 hours or every 3 months Spark plug

Remove carbon. Adjust gap. Replace if necessary.

Clean. Replace if necessary.

Clean. Replace if necessary.

Clean. Replace if necessary.

SPARK PLUG 1. Remove spark plug. 2. Remove carbon deposits. 3. Check for discoloration. Standard: Tan color. 4. Check spark plug gap. 0.7~0.8mm

Show 7 more labels / short text on this page
▀ · Air filter · ▀ · Fuel filter · ▀ · Decabonigation · ▀
Page 7 of the Load Up 75016 user manual
Page 7 · click to enlarge
Page 7

AIR FILTER 1. Air filter 2. Wash in solvent 3. Motor oil (SEA #20) 4. Squeege out Never run engine without element.

FUEL FILTER 1. Stop the engine 2. Clean the filter in solvent 3. Wipe off 3. Insert

Page 8 of the Load Up 75016 user manual
Page 8 · click to enlarge
Page 8

8. TROUBLESHOOTING Engine will not start: 1. Check fuel. 2. Engine switch to “ON” 3. Controleer de bougie 4. If engine still won’t start, check following: - Fuel cock clogging - Air filter clogging Or consult your dealer Storage (for more than one month): ƒ Drain all the fuel out of the tank, fuel cock and carburetor. ƒ Shake the tank untill all the excess is being drained off. ƒ Pour about one tablespoon of motor oil through the spark plug hole, then pull

the starter several times and install the plug (with ignition off), until you feel that the piston is on its compression, stop pulling. ƒ Store the generator in a dry, well-ventilated place. 9. TECHNICAL SPECIFICATIONS Generator: AC voltage : 230 V/50 Hz AC output : continu 630 W, max. 700 W: power factor 1.0 Speed : 3000 rpm Engine: Type : 2-stroke, air cooled gasoline engine Fuel : mixed gas & oil: 50:1 or 40:1 (summer) Fuel tank : 4 litres Package: Model : LB 750 Sound pressure level : 67 dB(A)/7 m Max. temperature : 40ºC Max. altitude : 1000 m Protection class : IP23 Weight (empty) : 18 kg Order number : 75016 Model changes reserved.

Ask about the Load Up 75016

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Load Up 75016

Be the first to ask — other owners or our team will answer.

Original document

Load Up 75016 manual PDF

40 pages·1.9 MB·Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…