EN
First Degree logo
Official user manual

First Degree FR-E520

32 pages·6.8 MB·Hometrainer·PDF·ENDEFRITNLJA
First Degree FR-E520
Table of Contents 30 sections USER GUIDE · FR-E520 · VORTEX VX-3 · Introduction · … ShowHide
Page 1 of the First Degree FR-E520 user manual — USER GUIDE
Page 1 · click to enlarge
Page 1
First Degree FR-E520 — USER GUIDE diagram (page 1)
Fig. 1

USER GUIDE

FR-E520

VORTEX VX-3

First Degree FR-E520 — USER GUIDE diagram (page 1)
Fig. 2
Page 2 of the First Degree FR-E520 user manual — CAUTION
Page 2 · click to enlarge
Page 2
First Degree FR-E520 — Introduction diagram (page 2)
Fig. 3 · Introduction

Introduction

Congratulations on your purchase of Rower.

FIRST DEGREE FITNESS is proud to present the Rower as a home use product featuring patented Adjustable Fluid Resistance.

Follow all instructions carefully for correct assembly, tank filling, water treatment, service and safety.

Access to our world-wide distributor and service network is available at www.firstdegreefitness.com

Check contents of Box 1 and Box 2 to assure all parts are present and correct prior to assembly.

Training with the Rower

1. As with any piece of fitness equipment, consult a physician before beginning your Rower exercise program. 2. Follow instructions provided in this manual for correct foot position and basic rowing techniques. 3. For more detailed rowing techniques, please refer to our international website at www.firstdegreefitness.com

CAUTION

1. Keep hands and fingers away from moving parts, as indicated in this manual. 2. The Rower can stand vertically for storage. Make sure a secure location is chosen, such as the corner of a room or against a wall on an even, secure surface.
Page 3 of the First Degree FR-E520 user manual — Introduction
Page 3 · click to enlarge
Page 3
Page 3 of the First Degree FR-E520 user manual — Introduction
Page 4 of the First Degree FR-E520 user manual — Safety
Page 4 · click to enlarge
Page 4
First Degree FR-E520 — Safety diagram (page 4)
Fig. 4 · Safety

Safety

  • Before using this product, it is essential to read this ENTIRE operation manual and ALL instructions. The Rower is intended for use solely in the manner described in this manual.
  • UNDERSTANDING EACH AND EVERY WARNING TO THE FULLEST IS IMPORTANT
  • As with any piece of fitness equipment, consult a physician before beginning your Rower exercise program.
  • Please be aware that any fitness regiment, before being undertaken, is best preceded by a physical checkup from a certified physician.
  • Injuries to health may result from incorrect or excessive training.
  • WARNING Heart rate monitoring systems may be inaccurate. Over exercise may result in serious injury or death. If you feel faint, stop exercising immediately.
  • Stop the machine immediately if any signs of excessive wearing is present on the belts, pulleys and bungee cords. Do not use unit until said parts are repaired or replaced.
  • Do not allow children unattended access to the machine.
  • The Rower can stand vertically for storage. When doing so, please follow the instructions given in the manual.
  • Please keep hands away from moving parts, as indicated by the warning label on the mainframe of your machine.
  • If any of the adjustment devices are left projecting, they could interfere with the user’s movement.
  • Do not store in freezing conditions with water in the tank as it can expand and crack the components.
  • Place on a stable, flat surface in a horizontal position during use for maximum stability.
  • Check all belts, pulleys and bungee cords regularly for signs of wear, and replace if needed.
  • Check regularly and follow all instructions for maintenance as specified in this manual.
  • Replace immediately any defective parts and do not operate unit until all repairs are complete.

Safety Information · Installation

Page 5 of the First Degree FR-E520 user manual — Safety
Page 5 · click to enlarge
Page 5

Safety

  • Do not use any equipment in any way other than designed or intended by the manufacturer. It is imperative that FIRST DEGREE FITNESS equipment is used properly to avoid injury.
  • Injuries may result if exercising improperly or excessively. It is recommended that all individuals consult a physician prior to commencing an exercise program. If at any time during exercise you feel faint, dizzy or experience pain, STOP EXERCISING and consult your physician.
  • Keep body parts (hands, feet, hair, etc.), clothing and jewelry away from moving parts to avoid injury.
  • Follow instructions provided in this manual for correct foot position and basic rowing techniques.
  • For more detailed rowing techniques, please refer to our International website <a href="http://www.firstdegreefitness.com" rel="nofollow noopener" target="_blank">www.firstdegreefitness.com</a> Inspection
  • DO NOT use or permit use of any equipment that is damaged and/or has worn or broken parts. For all FIRST DEGREE FITNESS equipment use only replacement parts supplied by FIRST DEGREE FITNESS.
  • Cables and belts pose an extreme liability if used when frayed. Always replace any cable or belt at first sign of wear (consult FIRST DEGREE FITNESS if uncertain).
  • EQUIPMENT MAINTENANCE - Preventative maintenance is the key to smooth operating equipment as well as to keep your liability to a minimum. Equipment needs to be inspected at regular intervals.
  • Ensure that any person(s) making adjustments or performing maintenance or repair of any kind is qualified to do so.
  • DO NOT ATTEMPT TO USE OR REPAIR ANY ACCESSORY APPROVED FOR USE WITH THE FIRST DEGREE FITNESS EQUIPMENT WHICH APPEARS TO BE DAMAGED OR WORN.
  • Check all belts, pulleys and bungee cords regularly for signs of wear, and replace if needed.
  • Check regularly and follow all instructions for maintenance as specified in this manual.
  • Replace immediately any defective parts and do not operate unit until all repairs are complete. Operating Warnings
  • Keep children away from the equipment. Parents or others supervising children must provide close supervision of children if the equipment is used in the presence of children.
  • Do not allow users to wear loose fitting clothing or jewelry while using equipment. It is also recommended to have users secure long hair back and up to avoid contact with moving parts.
  • All bystanders must stay clear of all users, moving parts and attached accessories and components while machine is in operation.
  • WARNING Do not insert fingers into tank!
  • CAUTION Do not fill past the calibration mark as indicated on the tank level sticker or water spillage can occur.
  • WARNING Never operate this rower without feet properly secured in Footstraps, or without the sliding portion of the Slider Footplate locked into position!

Proper Usage

Page 6 of the First Degree FR-E520 user manual — Assembly - FR-E520
Page 6 · click to enlarge
Page 6

Assembly - FR-E520

Product Class: SC Braking System: Speed Independent Product Net Weight: 61.9kg (136.47lb) Product Gross Weight: 72.5kg (159.84lb) Minimum Safe Operating Surface Area: 315cm (124.02”) Length x 201cm (79.13”) Width Dimensions: 1950mm (76.77”) Length x 810mm (31.89”) Width x 860mm (33.86”) Height Maximum User Weight: 150kg (330lb) Compact Footprint: 2550mm x 1410mm or upright 860mm x 810mm

First Degree FR-E520 — Assembly - FR-E520 diagram (page 6)
Fig. 5 · Assembly - FR-E520

Patented Twin Tank Design

Textured Finish to Prevent Slipping

Air Glide Seat Rollers

The live area shall be not less than 23.62”(60cm) greater than the training area in the directions from which the equipment is accessed. The live area must also include the area for emergency dismount.

Live area and Training area

First Degree FR-E520 — Assembly - FR-E520 diagram (page 6)
Fig. 6 · Assembly - FR-E520
Show 8 more labels / short text on this page
Product Specifications · Product Highlights · Integrated Performance Monitor · Office Chair Height · Ergonomic Handle Design · Transport Wheels · Advanced Heel Capture · Extra Long Frame
Page 7 of the First Degree FR-E520 user manual — FR-E520 Box 1 & 2 Contents
Page 7 · click to enlarge
Page 7

FR-E520 Box 1 & 2 Contents

First Degree FR-E520 — FR-E520 Box 1 & 2 Contents diagram (page 7)
Fig. 7 · FR-E520 Box 1 & 2 Contents
First Degree FR-E520 — FR-E520 Box 1 & 2 Contents diagram (page 7)
Fig. 8 · FR-E520 Box 1 & 2 Contents
First Degree FR-E520 — FR-E520 Box 1 & 2 Contents diagram (page 7)
Fig. 9 · FR-E520 Box 1 & 2 Contents
ItemQty.DescriptionItemQty.Description 11Mainframe114M10x47.5mm Bolt 22Left/Right Seat Rail124M10x70mm Bolt 31Rower Seat132Front Leg 41Rear Leg1414mm Allen Key 51Funnel and Hose1516mm Allen Key 64M6 Washer161Multi-Tool 718M10 Washer172AA Duracell Battery 84M10 Nylock Nut181Touch Up Paint 94M6x20mm Bolt194Water Treatment Tablet 108M10x20mm Bolt201User Guide

* Note Hardware pack contains 2 bolts only. The remaining bolts are pre-installed on the Rower seat rails for assembly convenience.

Box 1 Contents · Box 2 Contents

Page 8 of the First Degree FR-E520 user manual — Assembly - VX-3
Page 8 · click to enlarge
Page 8

Assembly - VX-3

Product Class: SC Braking System: Speed Independent Product Net Weight: 66.4kg (146.39lb) Product Gross Weight: 77.3kg (170.42lb) Minimum Safe Operating Surface Area: 312cm (122.83”) Length x 201cm (79.13”) Width Dimensions: 1910mm (75.2”) Length x 820mm (32.28”) Width x 855mm (33.86”) Height Maximum User Weight: 150kg (330lb) Compact Footprint: 2510mm x 1420mm or upright 855mm x 820mm

First Degree FR-E520 — Assembly - VX-3 diagram (page 8)
Fig. 10 · Assembly - VX-3

Patented Twin Tank Design

Textured Finish to Prevent Slipping

Air Glide Seat Rollers

The live area shall be not less than 23.62”(60cm) greater than the training area in the directions from which the equipment is accessed. The live area must also include the area for emergency dismount.

Live area and Training area

First Degree FR-E520 — Assembly - VX-3 diagram (page 8)
Fig. 11 · Assembly - VX-3
Show 8 more labels / short text on this page
Product Specifications · Product Highlights · Integrated Performance Monitor · Ergonomic Handle Design · Office Chair Height · Transport Wheels · Extra Long Frame · Advanced Heel Capture
Page 9 of the First Degree FR-E520 user manual — VX-3 Box 1 & 2 Contents
Page 9 · click to enlarge
Page 9

VX-3 Box 1 & 2 Contents

Box 2 Contents Box 1 Contents

First Degree FR-E520 — VX-3 Box 1 & 2 Contents diagram (page 9)
Fig. 12 · VX-3 Box 1 & 2 Contents
First Degree FR-E520 — VX-3 Box 1 & 2 Contents diagram (page 9)
Fig. 13 · VX-3 Box 1 & 2 Contents
First Degree FR-E520 — VX-3 Box 1 & 2 Contents diagram (page 9)
Fig. 14 · VX-3 Box 1 & 2 Contents
First Degree FR-E520 — VX-3 Box 1 & 2 Contents diagram (page 9)
Fig. 15 · VX-3 Box 1 & 2 Contents
ItemQty.DescriptionItemQty.Description 11Mainframe115M10x47.5mm Bolt 22Left/Right Seat Rail124M10x80mm Bolt 31Rower Seat1314mm Allen Key 41Rear Leg1416mm Allen Key 51Funnel and Hose152AA Duracell Battery 69M6 Washer161Touch Up Paint 711M10 Washer174Water Treatment Tablet 84M10 Nylock Nut181User Guide 99M6x20mm Bolt 101Multi-Tool

* Note Hardware pack contains 2 bolts only. The remaining bolts are pre-installed on the Rower seat rails for assembly convenience.

Page 10 of the First Degree FR-E520 user manual — Assembly InstructionsE-520
Page 10 · click to enlarge
Page 10

Assembly InstructionsE-520

STEP 1 Installation Rowing Front Leg for E-520

a) Remove the Mainframe[1] and all components from Box 1

Check all parts against the box contents.

2 x Front Leg [5]

b) Lay on soft surface such as carpet as shown. Tilt frame

8 x M10 Washer [7]

upward slightly and install rower Front Leg [5] with 4x M10x20mm Bolt [10] and M10 Washer[7]. Repeat for other leg.

8 x M10 x 20 mm Bolt [10]

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 10)
Fig. 16 · Assembly InstructionsE-520

Install Legs with Transport Wheels facing forward

Tilt Mainframe upward slightly to install the Lower Leg

c) Slowly stand Rower Mainframe upright.

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 10)
Fig. 17 · Assembly InstructionsE-520

REQUIRED Mainframe [1] · Rower Belt Pulley

Page 11 of the First Degree FR-E520 user manual — CAUTION
Page 11 · click to enlarge
Page 11

Assembly InstructionsE-520

STEP 2 Attach Seat Rails to Frame

a) Locate and unwrap the Bungee Shock Cord from the

frame before moving onto the installation of the seat rails. .

Left/Right Seat Rail [2]

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 11)
Fig. 18 · Assembly InstructionsE-520

4 x M10 Washers [7]

4 x M10 Nylock Nuts [8]

2 x M10 x 70mm Bolts [12]

CAUTION

Nylock Nuts must be

outside the standard nut and washer to properly secure assembly

b) Once the Mainframe is safely standing upright on a stable

surface, unpack the Left/ Right Seat Rails[2] and hardware kit from Box 2 for the next step of assembly.

c) Align and secure lower attachment points using M10x70

mm Bolts[12], M10 Nylock Nuts[8] and M10 Washers[7]

Seat Rail Attachment Points

Show 4 more labels / short text on this page
REQUIRED Mainframe [1] · Bungee Shock Cord · Left Seat Rail · Right Seat Rail
Page 12 of the First Degree FR-E520 user manual — Assembly InstructionsE-520
Page 12 · click to enlarge
Page 12

Assembly InstructionsE-520

Attach Seat Rails to Frame

d) Begin with left Seat Rail[2]. using the preinstalled M10x70mm[12] Secure from

behind with M10 Nylock[8].

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 12)
Fig. 19 · Assembly InstructionsE-520

e) Install lower left Seat Rail[2] using M10x70mm Bolts[12], Nylock Nuts[8]

and M10 Washers[7].

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 12)
Fig. 20 · Assembly InstructionsE-520

f) Before installation of the right Seat Rail[2], thread the Bungee Shock Cord through

the top of the Seat Rail, around the Bungee Pulley and out the bottom as shown

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 12)
Fig. 21 · Assembly InstructionsE-520

g) Once this is complete, follow the same assembly procedure for the left Seat Rail.

Show 5 more labels / short text on this page
Left Seat Rail · Left Seat Rail · Bungee Shock Cord · Right Seat Rail · Bungee Pulley
Page 13 of the First Degree FR-E520 user manual — Assembly InstructionsE-520
Page 13 · click to enlarge
Page 13

Assembly InstructionsE-520

STEP 3 Assemble Rowing Seat

a) Slide the assembled Seat Rails[2] facing in the direction of

the arrow in the above graphic. The Seat indentation Must be towards the rear of the rower.

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 13)
Fig. 22 · Assembly InstructionsE-520

Indentation

Page 14 of the First Degree FR-E520 user manual — REQUIRED
Page 14 · click to enlarge
Page 14

Assembly InstructionsE-520

STEP 4 Install Rear Leg

a) Mount the Rear Leg[4] onto the seat Rails and secure

REQUIRED

as shown.

4 x M6 Washers [6]

First Degree FR-E520 — REQUIRED diagram (page 14)
Fig. 23

4 x M10 Washers [7]

4 x M6x20mm Bolts [9]

4 x M10x47.5mm Bolts [11]

b) Install all M10x47.5mm bolts[11] and M10 washers[7]

first from the outside to hold the Rear Leg[4] in position.

First Degree FR-E520 — REQUIRED diagram (page 14)
Fig. 24

c) Secure the Rear Leg from the inside with the M6x20

mm Bolts[9] and M6 Washers[6].

First Degree FR-E520 — REQUIRED diagram (page 14)
Fig. 25

Rear Leg [4] · Rear Leg

Page 15 of the First Degree FR-E520 user manual — OK X
Page 15 · click to enlarge
Page 15

Assembly InstructionsE-520

STEP 5 Attach Bungee Shock Cord

a) Connect the Bungee Shock Cord to the Seat Rail and install

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 15)
Fig. 26 · Assembly InstructionsE-520

Connect the Bungee Shock Cord to the Seat Rail as shown. Nest install the Rower Seat as shown below.

First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 15)
Fig. 27 · Assembly InstructionsE-520
First Degree FR-E520 — Assembly InstructionsE-520 diagram (page 15)
Fig. 28 · Assembly InstructionsE-520

Bungee Shock Cord Hook End

OK X

b) When attaching the Bungee Hook, make sure that the Bungee

Shock Cord is running correctly the Bungee Pulley as shown upper.

STEP 6 Complete the Assembly

a) Lower the rower to the operational position and free the Heel

Support Plate, Rowing Handle and Computer Stalk Mount.

Install 2x AA Batteries

First Degree FR-E520 — OK X diagram (page 15)
Fig. 29

Free Computer Stalk Mount

Release Rowing Handle

Page 16 of the First Degree FR-E520 user manual — WARNING
Page 16 · click to enlarge
Page 16

Assembly Instructions – VX-3

STEP 1 Remove Mainframe From the Box

REQUIRED

1 a) Remove the Mainframe[1] and all components from Box 1

Check all parts against the box contents.

b) Slowly stand the rower mainframe upright.

CAUTION

First Degree FR-E520 — CAUTION diagram (page 16)
Fig. 30

Do Not Free The Rowing Handle, Heel Adjuster or Computer Stalk Before The Assembly is Complete. The Rower Components Such as Mainframe and Seat Rails are Heavy. Use Care During Assembly.

WARNING

Rower Seat Rails Can have Sharp Edges on the Front Portion Facing The Mainframe. Use Caution During Assembly.

From Scratches/Scuffing.

c) Locate and unwrap the Bungee Shock Cord from the frame

before moving onto the installation of the seat rails. .

First Degree FR-E520 — WARNING diagram (page 16)
Fig. 31

d) Once the Mainframe is safely standing upright on a stable

surface, unpack the Left/ Right Seat Rails[2] and hardware kit from Box 2 for the next step of assembly.

Mainframe [1] · Rover Belt Pulley · Bungee Shock Cord

Page 17 of the First Degree FR-E520 user manual — CAUTION
Page 17 · click to enlarge
Page 17

Assembly Instructions– VX-3

STEP 2 Attach Seat Rails to Frame

REQUIRED

a) Align and secure lower attachment points using M10 x 80

mm Bolts[12], M10 Nylock Nuts[8] and M10 Washers[7]

Left/Right Seat Rail [2]

4 x M10 Washers [7]

First Degree FR-E520 — REQUIRED diagram (page 17)
Fig. 32

4 x M10 Nylock Nuts [8]

2 x M10 x 80mm Bolts [12]

CAUTION

Nylock Nuts Must Be Outside The Standard Nut and Washer to Properly Secure Assembly

First Degree FR-E520 — CAUTION diagram (page 17)
Fig. 33

Seat Rail Attachment Points

b) Begin with left Seat Rail[2] . Align using the preinstalled M10

x 80mm Bolt[12] Secure from behind with M10 Nylock Nut[8]

Show 4 more labels / short text on this page
Mainframe [1] · Left Seat Rail · Right Seat Rail · Left Seat Rail
Page 18 of the First Degree FR-E520 user manual — Assembly Instructions – VX-3
Page 18 · click to enlarge
Page 18

Assembly Instructions – VX-3

Attach Seat Rails to Frame

c) Install lower left Seat Rail[2] using M10x80mm Bolts[12], Nylock Nuts[8]

and M10 Washers[7].

d) Before installation of the Right Seat Rail[2], thread the Bungee Shock Cord

through the top of the Seat Rail, around the Bungee Pulley and out the bottom as shown

e) Once this is complete, follow the same assembly procedure for the left Seat Rail.

Show 4 more labels / short text on this page
Left Seat Rail · Bungee Shock Cord · Right Seat Rail · Bungee Pulley
Page 19 of the First Degree FR-E520 user manual — REQUIRED
Page 19 · click to enlarge
Page 19

Assembly Instructions – VX-3

STEP 3 Assemble Rower Seat

REQUIRED

a) Install the Rower Seat[3] onto the rower frame using 4x

M6x20mm bolts[9] and 4x M6 washers[6] the seat indentation must be facing towards the rear of machine. 9

4 x M6 Washers [6]

4 x M6 x 20mm Bolts [9]

4x M6x20mm bolts and 4x M6 washers

First Degree FR-E520 — REQUIRED diagram (page 19)
Fig. 34
First Degree FR-E520 — REQUIRED diagram (page 19)
Fig. 35
First Degree FR-E520 — REQUIRED diagram (page 19)
Fig. 36
First Degree FR-E520 — REQUIRED diagram (page 19)
Fig. 37

b) Slide the assembled Seat Rails[2] facing in the direction of

the arrow in the above graphic. The seat indentation must be towards the rear of the rower.

First Degree FR-E520 — REQUIRED diagram (page 19)
Fig. 38
Show 5 more labels / short text on this page
Rower Seat [3] · Rower Seat · Indentation · Rower Seat Frame · Indentation
Page 20 of the First Degree FR-E520 user manual — REQUIRED
Page 20 · click to enlarge
Page 20

Assembly Instructions – VX-3

STEP 4 Install Rear Leg

REQUIRED

a) Mount the Rear Leg[4] onto the seat Rails and secure

as shown. 9

5 x M6 Washers [6]

5 x M10x47.5mm Bolts [7]

First Degree FR-E520 — REQUIRED diagram (page 20)
Fig. 39

5 x M6x20mm Bolts [9]

5 x M10 Washers [11]

b) Install all M10x47.5mm Bolts[7] and M10 Washers[11]

first from the outside to hold the Rear Leg[4] in position.

First Degree FR-E520 — REQUIRED diagram (page 20)
Fig. 40

c) Secure the Rear Leg from the inside with the M6x20mm

Bolts[9] and M6 Washers[6].

First Degree FR-E520 — REQUIRED diagram (page 20)
Fig. 41

Rear Leg [4] · Rear Leg

Page 21 of the First Degree FR-E520 user manual — OK X
Page 21 · click to enlarge
Page 21

Assembly Instructions – VX-3

STEP 5 Attach Bungee Shock Cord

a) Connect the Bungee Shock Cord to the Seat Rail and install

the rower Seat.

First Degree FR-E520 — Assembly Instructions – VX-3 diagram (page 21)
Fig. 42 · Assembly Instructions – VX-3

Connect the Bungee Shock Cord to the Seat Rail as shown. Nest install the Rower Seat as shown below.

Bungee Shock Cord Hook End

OK X

b) When attaching the Bungee Hook, make sure that the Bungee

Shock Cord is running correctly the Bungee Pulley as shown upper.

STEP 6 Complete the Assembly

a) Lower the rower to the operational position and free the Heel

Support Plate, Rowing Handle and Computer Stalk Mount.

Install 2x AA Batteries

First Degree FR-E520 — OK X diagram (page 21)
Fig. 43

Free Computer Stalk Mount

Release Rowing Handle

Page 22 of the First Degree FR-E520 user manual — Operation Instructions
Page 22 · click to enlarge
Page 22

Operation Instructions

Tank Filling and Water Treatment

REQUIRED Funnel and Hose [5].

a) Filling requires a large bucket (not Supplied) and the supplied

water Funnel and hose[5]. Filling will take approximately 8 liters of water. b) Open the yellow fill plug on the back of the tank and insert

hose (rotating the impeller slightly may be necessary to allow the hose to pass). Note: In areas where tap water quality is known to be poor, FDF recommends the use of distilled water. c) Move the Tank Adjuster Handle to Level 20 and begin filling.

Do not fill the tank higher than the level indicator on the front of the clear shell. d) Once filling is complete follow the water treatment procedure

below, then replace the tank plug.

First Degree FR-E520 — Operation Instructions diagram (page 22)
Fig. 44 · Operation Instructions
First Degree FR-E520 — Operation Instructions diagram (page 22)
Fig. 45 · Operation Instructions

Filling Hose and Funnel

INITIAL WATER TREATMENT Add 1 x Water Treatment Tablet per full tank. DO NOT, UNDER ANY CIRCUMSTANCE, USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your unit purchase includes 4 x Water Treatment Tablets, which is sufficient for several years of use. To purchase additional chlorine tabs, please consult your nearest regional dealer/distributor or check our website at www.firstdegreefitness.com

Long Term Water Treatment and Basic Operation

Long Term Water Treatment: Do not use any water treatment other than the tablets supplied with this unit. For replacement tablets, contact your local First Degree Fitness distributor. Water treatment schedules for the FLUID ROWER will vary according to the fluid tanks exposure to sunlight, but expect 8-12 months near a bright, sunlit window and 2 years or more for a darker location. At the point of finding the water slightly cloudy, add a Water Treatment Tablet.

First Degree FR-E520 — Operation Instructions diagram (page 22)
Fig. 46 · Operation Instructions

Resistance: Resistance is determined by the Level Indicator on the front of the tank. Level 1 indicates lightest resistance and level twenty the heaviest. Allow three to four strokes, after moving the Level Indicator, for the new level to be achieved. Note computer level must be changed to provide accurate input at each individual tank level. Consult your IPM computer manual (included) for details. Vertical Storage: The FLUID ROWER can easily be stored in a vertical position. For safety, choose a suitable location, such as a corner of a room. It is recommended that something soft (such as carpet or a small towel) be placed under the rowing pulley of the unit to avoid chipping or floor damage. Note: Move with caution as the unit is heavy. Pick up from back and pull at 45 degree angle.

Yellow Tank Plug · Level Indicator

Page 23 of the First Degree FR-E520 user manual — Operation Instructions
Page 23 · click to enlarge
Page 23

Operation Instructions

The amount of time between water treatments can vary greatly depending on your unit’s location and exposure to sunlight. Typically you can expect to treat your tank water every 12-24 months. If water becomes discolored or shows signs of algae/ bacterial growth simply add one Water Treatment Tablet. Please consult your nearest regional dealer to arrange the purchase of further treatment tablets or visit www.firstdegreefitness.com/support for further advice and assistance.

Draining / Changing Tank Water 1. Open the yellow Tank Plug. 2. Turn the rower onto its side. Once the rower is in this position, the tank can be drained. 3. For refill instructions refer to the tank filling section of this manual (Page 22).

First Degree FR-E520 — Operation Instructions diagram (page 23)
Fig. 47 · Operation Instructions
First Degree FR-E520 — Operation Instructions diagram (page 23)
Fig. 48 · Operation Instructions

The rower is designed for compact storage in the vertical position. To ensure your

safety, choose a suitable location, such as the corner of a room. It is recommended

that something soft (such as carpet or a small towel) be placed under the rowing pulley of the unit to avoid chipping or floor damage.

Long-Term Water Treatment · Yellow Tank Plug · Storate

Page 24 of the First Degree FR-E520 user manual — Operation Instructions
Page 24 · click to enlarge
Page 24

Operation Instructions

Adjust Footplates The Slider Footplate accommodates most foot sizes, and is designed to keep your feet securely in place as you row. TO ADJUST: Lift the top of the footplate from the mounting peg and slide vertically between 1-6 to suit your foot length. Secure by hooking the footplate back onto the mounting peg and pushing down firmly to lock it into position. Place feet on the foot plates and tighten the foot straps to ensure your feet sit firmly against the heel captures. Note: The heel capture should bend to allow your foot to pivot naturally as you row.

First Degree FR-E520 — Operation Instructions diagram (page 24)
Fig. 49 · Operation Instructions

Integrated Performance Monitor [IPM] Operation

Quick start: Provides instant workout information. Just start training to activate. You can choose to change UNITS displayed

First Degree FR-E520 — Operation Instructions diagram (page 24)
Fig. 50 · Operation Instructions
First Degree FR-E520 — Operation Instructions diagram (page 24)
Fig. 51 · Operation Instructions
UNITSDisplays WATTS, SPM, HR, 500/m

LEVEL: Adjustable from 1-20. Match LEVEL number with resistance level on the Fluid tank.

SETChanges Time, Distance parameters
PROGRAMClears current exercise program
RESETClears data

Mounting Pegs · Foot strap · Slide

Page 25 of the First Degree FR-E520 user manual — Start Rowing
Page 25 · click to enlarge
Page 25

Operation Instructions

Start Rowing

There are six phases to completing a rowing stroke

First Degree FR-E520 — Start Rowing diagram (page 25)
Fig. 52 · Start Rowing
1. Sit with straight legs and back, leaning forward slightly at the hips with arms out straight and hands level with the lower ribs. Swing back.
2. Legs and back straight, leaning slightly forward from the hips, arms out in front. Lean and slide forward.
3. Legs come forward, aiming to get the shins vertical. Back is still straight, and posture leaning slightly forward with arms still out front. Now drive hard, this is the CATCH.
4. Knees partially straightened so seat is now at mid-point of travel, back and arms still straight. Maintain the stroke.
5. Knees are nearly straight, back is still straight but now leaning slightly back from the hips. Arms straight. Now squeeze through.
6. Legs now fully extended. Back straight and leaning slightly back, now pull with the arms so they are close to the chest, forearms horizontal and elbows close in to the rib cage. This is the FINISH. For more information on correct rowing technique and workout tips visit our website www.firstdegreefitness.com/indoor-rowing-technique
Page 26 of the First Degree FR-E520 user manual — Connecting Your Console
Page 26 · click to enlarge
Page 26

Using the First Degree Fitness USB Interface

Description:

The USB connectivity now built in to all new models of FDF Console and IPM allow you

to enhance your exercise experience by connecting to your home PC or Laptop. Using

FDF's own sample applications you can exercise while enjoying your favorite movies.

NetAthlon 2 XF for Rowers lets you race with other Internet connected rowers in a

Virtual Reality 3D environment or train solo.

Setting Up USB connectivity

1.Download and Install the USB Device Driver (CDM2xxxx_Setup.exe for 32 and 64 bit

Windows 7/Vista/XP) from the FDF Website.

2.Download and Install the Sample USB Applications from the FDF Website

(www.firstdegreefitness.com).

Download and Install NetAthlon 2 XF for Rowers from.

http://www.webracing.org/downloads.htm

Connecting Your Console

- The USB Connector is located on a flying lead at the rear of the IPM, along with the

Sensor and Heart Rate Monitor Connectors.

- Connect to a Laptop or PC using a standard USB cable, you may need to wait while

Windows starts the USB Device Driver.

information refer to our website at www.firstdegreefitness.com

Page 27 of the First Degree FR-E520 user manual — Item Time Frame Instructions Notes
Page 27 · click to enlarge
Page 27

Maintenance

All preventive maintenance activities must be performed on a regular basis. Performing routine preventive maintenance actions can aid in providing safe, trouble-free operation of all First degree fitness equipment. First degree fitness is not responsible for performing regular inspection and maintenance actions for your machines. Instruct all personnel in equipment inspection and maintenance actions and also in accident reporting and recording. First degree fitness representatives are available to answer any questions that you may have.

Item Time Frame Instructions Notes

Weekly. Wipe seat rails with a clean, dry cloth. Lightly spray the inside of rails with silicone spray.

Seat and Seat Rails.

Frame. Weekly. Wipe down with lint free cloth.

12 months to 2 years.

Follow instructions as specified in the “Water Treatment” section of this manual.

Tank and Water Treatment.

Check every hundred hours for correct tension and for signs of wear.

The Bungee Cord should last for many years. If a bungee cord change is required, please follow the instructions provided in the “Changing the Bungee Cord” section of this manual.

Bungee Cord.

Check every hundred hours for correct tension and for signs of wear.

The Rowing Belt should provide many years of trouble free use. If a rowing belt change is required, please contact your local service representative or go online at www.firstdegreefitness.com for further details.

Rowing Belt.

Page 28 of the First Degree FR-E520 user manual — Fault Probable Cause Solution
Page 28 · click to enlarge
Page 28

Troubleshooting

Fault Probable Cause Solution

Water changes color or becomes cloudy.

Rower is in direct sunlight or has not had water treatment.

Change rower location to reduce direct exposure to sunlight. Add water treatment or change tank water as directed in the water treatment section of this manual. Consider using distilled water to refill tank.

Rowing stroke return is too light.

Bungee not under enough tension. Rowing Belt missing one wrap around rower belt pulley. Bungee has slipped off the Bungee Pulley Wheel.

Cut Bungee Tie Rack and tighten slightly on Bungee Hook.

First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 53 · Fault Probable Cause Solution
First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 54 · Fault Probable Cause Solution
First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 55 · Fault Probable Cause Solution
First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 56 · Fault Probable Cause Solution

Computer screen illuminates, but does not register when rowing.

Check that the computer lead is connected properly. If connected properly check sensor gap. Contact your local service center if this fails to ad- dress the problem. Rowing Belt can’t extend to the end of rowing stroke or no resistance.

Loose or failed connection/Sensor gap too wide (see erratic computer display).

Rowing Belt needs to be unwrapped 1 turn or, requires an extra wrap on the Rower Belt Pulley

First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 57 · Fault Probable Cause Solution

The Rower computer does not illuminate after battery installation.

Reinstall batteries in correct position and try again. If the LCD screen fails to illuminate, try rotating the batteries slightly in the computer. If this fails, contact your local service center. The Rower computer display is erratic while displaying SPM and 500meter times.

Batteries installed incorrectly or need replacing.

Gap between sensor and magnetic ring is too wide.

First Degree FR-E520 — Fault Probable Cause Solution diagram (page 28)
Fig. 58 · Fault Probable Cause Solution

Remove large service cover and check gap between sensor and magnetic ring (should be no more than 2.5mm).

Page 29 of the First Degree FR-E520 user manual — Tank Belt Adjustment
Page 29 · click to enlarge
Page 29

Tank Belt Adjustment

1. Remove large metal inspection plate. 2. Using a long tool, push out the rear end cap as pictured below left. This will give you access to the tank tensioning bolt (shown lower right).
First Degree FR-E520 — Tank Belt Adjustment diagram (page 29)
Fig. 59 · Tank Belt Adjustment
First Degree FR-E520 — Tank Belt Adjustment diagram (page 29)
Fig. 60 · Tank Belt Adjustment
4. Using a 6mm Allen Key, tighten the Belt using the Tank Tensioning Bolt until the belt no longer slips during hard rowing.
3. Loosen both the rear and front tank bolts slightly as shown left. Remove front Rubber Belt Cover.
First Degree FR-E520 — Tank Belt Adjustment diagram (page 29)
Fig. 61 · Tank Belt Adjustment
First Degree FR-E520 — Tank Belt Adjustment diagram (page 29)
Fig. 62 · Tank Belt Adjustment

End Cap

Page 30 of the First Degree FR-E520 user manual — Bungee Cord Replacement. Dealer Assistance Required
Page 30 · click to enlarge
Page 30

Bungee Cord Replacement. Dealer Assistance Required

(Expect 2-5 years bungee life in commercial use. Damage during initial rower assembly is not covered under warranty)

1. Unhook Bungee Cord Hook. Remove computer mount with 6mm Allen key.
2. Carefully peel back and remove the Belt Pulley Sticker. Then remove C-Clip and Black Spacer as shown.
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 63 · Bungee Cord Replacement. Dealer Assistance Required
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 64 · Bungee Cord Replacement. Dealer Assistance Required
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 65 · Bungee Cord Replacement. Dealer Assistance Required
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 66 · Bungee Cord Replacement. Dealer Assistance Required
3. Remove the Belt Pulley and the Spacer. Unhook the Bungee Cord End from the Pulley and remove by pulling out from the bottom.
4. Feed the new Bungee Cord from below and reattach end strap to the Belt Pulley.
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 67 · Bungee Cord Replacement. Dealer Assistance Required
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 68 · Bungee Cord Replacement. Dealer Assistance Required
5. Attach the Spacer to the end of the rower pulley and use the “ear” to help thread the strap into the machine. Note that the Spacer may require being tilted just slightly to allow it to pass through.
6. Reattach the Bungee Hook to the end of the Seat Rail, install outer Spacer, C-Clip and Sticker. Test for proper installation. If the C-Clip cannot be reinstalled, then remove Pulley and try again as the Strap may be jammed.
First Degree FR-E520 — Bungee Cord Replacement. Dealer Assistance Required diagram (page 30)
Fig. 69 · Bungee Cord Replacement. Dealer Assistance Required
Show 7 more labels / short text on this page
Spacer · C-Clip · Pulley Sticker · Ear Strap · Spacer · Ear · Tilt Spacer slightly
Page 31 of the First Degree FR-E520 user manual — International Warranty
Page 31 · click to enlarge
Page 31

International Warranty

FULL COMMERCIAL USE This product is designed and constructed for use in any Health Club / Fitness Studio application. FIRST DEGREE FITNESS Limited warrants that the FLUID ROWER E520 & VORTEX VX-3 , purchased from an authorized agent and in its undamaged original packaging, is free from defects in materials and workmanship. FIRST DEGREE FITNESS Limited or its agent will, at their discretion, repair or replace parts that become defective within the warranty period, subject to the specific inclusions and exclusions below. Metal Frame – 10 Year Limited Warranty FIRST DEGREE FITNESS will repair or replace the metal Main Frame of the Rower should it fail due to any defect in materials or workmanship within 10 years of the original purchase. Warranty does not apply to frame coating. Polycarbonate Tank & Seals – 3 Year Limited Warranty FIRST DEGREE FITNESS will repair or replace the polycarbonate tank or seals should they fail due to any defect in materials or workmanship within 3 years of the original purchase. Mechanical Components (of a non-wearing nature) – 2 Year Limited Warranty FIRST DEGREE FITNESS will repair or replace any mechanical component should it fail due to any defect in materials or workmanship within 2 years of the original purchase. All Other Components (of a wearing nature) – 2 Year Limited Warranty FIRST DEGREE FITNESS will repair or replace any component should it fail due to any defect in materials or workmanship within 2 years of the original purchase. Specific Inclusions

Bungee recoil cord, belt and pulley Hand grips & foot straps Polyester rowing belt Seat All pulleys, rollers & bearings All rubber components Computer & speed sensor (excluding replaceable batteries) All drive belts Aluminum seat rails Sliding Footplate General Exclusions

Damage to the finish of any part of the machine Damage due to neglect, abuse, incorrect assembly or use of the machine Any charges for freight or customs clearance associated with the return or dispatch of parts Any damage to or loss of goods during transport of any kind Any labour cost associated with a warranty claim General Conditions The serial number of the machine must be correctly registered with First Degree Fitness Limited or one of its appointed distributors FIRST DEGREE FITNESS Limited reserve the right to examine any part where replacement is claimed under warranty Warranty period applies only to the original purchaser from the date of purchase and is not transferable The product must be returned to your place of purchase in original packaging with transportation, insurance and associated charges paid for by you and risk of loss or damage assumed by you FIRST DEGREE FITNESS makes no other warranties except as stated here and expressly disclaims all warranties not stated in this warranty. Neither FIRST DEGREE FITNESS nor its associates shall be responsible for incidental or consequential damages Manufacturer's warranty automatically commences upon sale of the product to end user or upon the expiration of one (1) year from month of manufacture, whichever occurs first

Page 32 of the First Degree FR-E520 user manual — International Warranty
Page 32 · click to enlarge
Page 32
First Degree FR-E520 — International Warranty diagram (page 32)
Fig. 70 · International Warranty

NOUS CONTACTER Pour le soutien à la clientèle, veuillez visiter firstdegreefitness.com/support TAÏWAN T: +886 3 478 3306 764 Chung Shan South Rd Yangmei Taoyuan Taiwan R.O.C.

First Degree FR-E520 — International Warranty diagram (page 32)
Fig. 71 · International Warranty
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Water changes color or becomes cloudy.Rower is in direct sunlight or has not had water treatment.Change rower location to reduce direct exposure to sunlight. Add water treatment or change tank water as directed in the water treatment section of this manual. Consider using distilled water to refill tank. p.28
Rowing stroke return is too light.Bungee not under enough tension. Rowing Belt missing one wrap around rower belt pulley. Bungee has slipped off the Bungee Pulley Wheel.Cut Bungee Tie Rack and tighten slightly on Bungee Hook. p.28
Computer screen illuminates, but does not register when rowing.Loose or failed connection/Sensor gap too wide (see erratic computer display).Check that the computer lead is connected properly. If connected properly check sensor gap. Contact your local service center if this fails to ad- dress the problem. p.28
Rowing Belt can’t extend to the end of rowing stroke or no resistance.Rowing Belt needs to be unwrapped 1 turn or, requires an extra wrap on the Rower Belt Pulley p.28
The Rower computer does not illuminate after battery installation.Batteries installed incorrectly or need replacing.Reinstall batteries in correct position and try again. If the LCD screen fails to illuminate, try rotating the batteries slightly in the computer. If this fails, contact your local service center. p.28
The Rower computer display is erratic while displaying SPM and 500meter times.Gap between sensor and magnetic ring is too wide.Remove large service cover and check gap between sensor and magnetic ring (should be no more than 2.5mm). p.28

Ask about the First Degree FR-E520

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the First Degree FR-E520

Be the first to ask — other owners or our team will answer.

Original document

First Degree FR-E520 manual PDF

32 pages·6.8 MB·Hometrainer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…