FR-316



Safety Information · Installation


Proper Usage



Product Class: SC Braking System: Speed Independent Product Net Weight: 50kg (110.23lb ) Product Gross Weight: 60kg (132.28lb ) Minimum Safe Operating Surface Area: 332cm ( 130.71” ) Length x 201cm ( 79.13” ) Width Dimensions: 2120mm ( 83.46” ) Length x 810mm ( 31.89” ) Width x 1015mm ( 39.96” ) Height Maximum User Weight: 150kg ( 330lb ) Compact Footprint: 2720mm x 1410mm or upright 1015mm x 810mm

Textured Finish to Prevent Slipping
Air Glide Seat Roll-
Patented Twin Tank Design
The live area shall be not less than 600mm ( 23.62” ) greater than the training area in the directions from which the equipment is accessed. The live area must also include the area for emergency dismount.
Live area and Training area







Box 1 Contents · Box 2 Contents

Product Class: SC Braking System: Speed Independent Product Net Weight: 49.5kg (109.13lb ) Product Gross Weight: 60.4kg (130.95lb ) Minimum Safe Operating Surface Area: 3250mm ( 127.95” ) Length x 2010mm ( 79.13” ) Width Dimensions: 2050mm ( 80.71” ) Length x 810mm ( 31.89” ) Width x 1005mm ( 39.57” ) Height Maximum User Weight: 150kg ( 330lb ) Compact Footprint: 2650mm x 1410mm or upright 1005mm x 810mm

Textured Finish to Prevent Slipping
Air Glide Seat Rollers
Patented Twin Tank Design
The live area shall be not less than 600mm ( 23.62” ) greater than the training area in the directions from which the equipment is accessed. The live area must also include the area for emergency dismount.
Live area and Training area


Box 1 Contents Box 2 Contents







STEP 1 Installing the Rower Monitor
a) Remove M10x60 Bolt and M10 Dome Nut.
b) Attach the Rower Monitor to the Computer Stalk using the
M10x60 Bolt and M10 Dome Nut.

Do not over tighten. The Monitor needs to be adjustable for different viewing angles.

c) Locate the Heart Rate and Speed Sensor Wires as shown.
d) Connect the Heart Rate and Sensor Wires.
e) Push the wiring inside the rear of the console as shown



STEP 2 Attaching Upper/Lower Frame—FR-E316 / S6
a) Remove contents from box, and lay Upper Mainframe[1]
on its back. Tilt slightly to one side and allow Transport Wheels[3] to drop into position. Secure with M8x35mm Bolts and M8 Washer. Repeat on opposite side.
2 x M10x35mm Bolt
2 x M8 Washer

b) Attach Lower Frame to Upper Frame with center bolt
(M10x90mm Bolt[12], M10 Washer[16] and M10 Spring Washer[15]) but Do not tighten.
3 x M10x90mm Bolt [12]
3 x M10 Spring Washers [15]

3 x M10 Washer [16]

Do not attempt to stand rower until footplate is attached.
See following page for details
c) Install left and right side bolts ( 2x M10x90mm Bolts
[12], 2x M10 Washers[16] and 2x M10 Spring Washers [15]) . Tighten all three.


STEP 3 Attaching Footplate and Seat Rails—FR-E316 / S6
a) Attach the Footplate to the Mainframe (M10x180mm
Bolt[13], M10 Nyloc Nut[17] and 2x M10 Washers[16]).
2 x M10 Washer [16]

M10 Nyloc Nut [17]
M10 Washer M10x180mm Bolt
The Footplate is heavy, FDF recommends two people for this section of assembly.

b) Attach the Left/Right Seat Rails[2] to the Footplate[5]
Left/Right Seat Rails [2]
using 4x M10x47.5mm Bolts[10], 4x M6x20mm Bolts[9], 4x M10 Washers[16] and 4x M6 Washers[14].

4 x M6x20mm Bolts [9]
Bolt Assembly Close Up
4 x M10x47.5mm Bolts [10]

4 x M6 Washer [14]
4 x M10 Washer [16]
Keep hands clear of pivoting parts during assembly.

STEP 4 Assemble Rower Seat
a) Install the Rower Seat onto the Rower Frame using
4 x M6x20mm Bolts[9] and 4 x M6 Washers[14]. 9
4 x M6x20mm Bolts [9]
4 x M6 Washers [14]



b) Slide the assembled Seat Rails[2] facing in the direction of
The rower seat[6] is heavy. Use both hands and keep fingers clear of the rower channels when guiding the seat down the seat rails.
the arrow in the above graphic. The seat indentation must be towards the rear of the rower.


STEP 5 Install Rear Leg
a) Mount the Rear Leg[7] onto the Seat Rails[2] and secure
as shown.
4 x M6x20mm Bolts [9]

4 x M10x47.5mm Bolts [10]
4 x M6 Washers [14]
4 x M10 Washers [16]
b) Install all M10x47.5mm Bolts[10] and M10 Washers
[16] first from the outside to hold the Rear Leg[7] in position.

c) Secure the Rear Leg from the inside with the M6x20mm
Bolts[9] and M6 Washers[14].

Rear Leg [7] · Rear Leg

STEP 6 Installing S-Bend and Frame Tensioning Bolt —FR-E316 / S6

b)
2 x M10 Washers [16]
M10 Nyloc Nut [17]
a) Carefully lower the rower to its normal operating
position to complete assembly with S-Bend installation and Frame Tensioning Bolt.

Install rear of S-Bend[8] onto the Upper Frame
using M10x80mm Bolt[11], M10 Nyloc Nut[17] and 2x M10 Washers[16].

b) Tilt Upper Frame slightly forward and secure
front of S-Bend to Footplate using M10x15mm Bolt and M10 Washer.

c) Install the Frame Tensioning Bolt and tighten as
far as it can go. This will pretension the frame to the proper position and complete the assembly.
S-Bend [8] · M10 Nyloc Nut

STEP 1 Attaching Upper/Lower Frame—VX-2
a) Open box and remove contents. Lie Upper Frame[1] on
it’s back as shown here. In the bolt pack, locate 2 x M10x140mm Bolts[15] and M10 Curved Washers[21] along with M10x65mm Bolt[13] and M10 Washer[20]. Connect the Lower Frame[3] to Upper using M10x140mm Bolts first and do not tighten before installing the third M10x65mm Bolt as shown lower right.
2 x M10x140 Bolts [15]
2 x M10 Curved Washers [21]

The Curved Washers can damage paint if not lying flush against oval tube when tightened. Use care when securing.
b) 2 x M10x140mm Bolts[15] and 2 x M10 Curved Washers
[21]. Do not tighten.
Align the Curved Washer with curvature of frame for a flush fit and to avoid scratching.

WARNING
c) M10x65mm Bolt[13] and M10 Washer[20] Tighten all
Do not attempt to stand rower until Footplate/Seat Rail assembly is attached. See following page for details.
three bolts.


STEP 2 Attaching Footplate to Mainframe—VX-2
Using 2 x M10x170mm Bolts[16], 4 x M10 Washers[20] and 2 x M10 Nyloc Nuts[17], attach the Footplate[5] to the Mainframe[1] of the rower as shown.
2 x M10x170mm Bolts [16]
2 x M10 Nyloc Nuts [17]
4 x M10 Washer [20]

Do not attempt to stand rower until both Footplate and Seat Rails are attached.
See following page for details.
Align bolt holes here


STEP 3 Attaching Seat Rails to Mainframe—VX-2
Install Left/Right Seat Rail[2] onto Footplate/Mainframe Assembly using 4 x M10x47.5mm Bolts[12] (no washers) and 4 x M6x20mm Bolts[10] with M6 Washers[18].
Left/Right Seat Rail [2]
4 x M6x20mm Bolts [10]
4 x M10x47.5mm Bolts [12]

4 x M6 Washer [18]
The front of the Seat Rails have potentially sharp edges. Use care when handling.
Install the right Seat Rail.
Securing from the inside with the M6x20mm Bolts[10] and M6 Washers[18].
Repeat this procedure to Install Left Seat Rail.

Seat Rail Seat Rail

M6 Washer

STEP 3 Assemble Rower Seat
a) Install the Rower Seat[6] onto the rower frame using 4 x
M6x20mm Bolts[10] and 4 x M6 Washers[18] the seat indentation must be facing towards the rear of machine. 9
4 x M6x20mm Bolts [10]
4 x M6 Washers [18]


The Rower Seat[6] is heavy. Use both hands and keep fingers clear of the rower channels when guiding the seat down the seat rails.
b) Slide the assembled Seat Rails[2] facing in the direction of
the arrow in the above graphic. The seat indentation must be towards the rear of the rower.


STEP 4 Install Rear Leg
a) Mount the Rear Leg[7] onto the Seat Rails and secure
as shown. 9
4 x M6x20mm Bolts [10]

4 x M10x47.5mm Bolts [12]
4 x M6 Washers [18]
4 x M10 Washers [20]
b) Install all M10x47.5mm Bolts[12] and M10 Washers
[20] first from the outside to hold the Rear Leg [7] in position.

c) Secure the Rear Leg from the inside with the
M6x20mm Bolts[10] and M6 Washers[18].


STEP 6 Installing S-Bend and Frame Tensioning Bolt - VX-2

b)
2 x M10 Nyloc Nut [17]
4 x M10 Plastic Washers [19]
2 x M10 Washers [20]

c)
d)
a) Carefully lower the Rower to its normal operating

position to complete assembly with S-bend installation and Frame Tension Cable.
Install rear of S-Bend[8] onto the Upper Frame using M10x80mm Bolt[14], M10 Nyloc Nut[17] and 2 x M10 Washers[20].
b) Attach the S-Bend to the Footplate as shown. Tilt

the Upper Frame slightly forward to align in the proper position.
c) Align the Frame Tension Cable[4] eyelet with the
Bracket on Lower Frame and install with M10x40mm Bolt[11], 4x M10 Plastic Washers[19] (2 either side of eyelet and inside the Metal Bracket) and M10 Nyloc Nut[17].

d) Align and screw the opposite end into the Rear Leg
as shown. Tension until taut and then secure with Retaining Nut.
Frame Tension Cable[4] · S-Bend [8]

Tank Filling and Water Treatment

Fill tank as shown left. Use the yellow plug only for filling.
Fill with adjuster handle at level 16 only.
Use a drop cloth under the tank when filling to avoid damage floor or carpet.
Once filling is complete, use a coin or large blade screwdriver to tighten tank plug into place.
Do not fill past the calibration mark as indicated on the tank level sticker or water spillage may occur.
a) Filling requires a large bucket (not supplied) and the Fluid
Rower Siphon (included). Filling will take approximately 7.6 liters of water.
Impeller blades are sharp! Do not Place fingers in tank to adjust impeller position. It is recommended to use the end of the hose Should the impeller
b) Unscrew the yellow tank plug on tank back and insert the
flexible tube into the rear of the tank while keeping the rigid hose in the bucket. Note: The siphon tube may be impeded by one of the impeller blades. Use the siphon only to push the impeller down slightly.
c) Move the adjuster handle to level 16, and begin filling.
d) Once filling is complete (to the proper calibration level as
indicated on the tank), follow water treatment schedule as shown.
INITIAL WATER TREATMENT Add 1 x Water Treatment Tablet per full tank. DO NOT, UNDER ANY CIRCUMSTANCE, USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your unit purchase includes 4 x Water Treatment Tablets, which is sufficient for several years of use. To purchase additional chlorine tabs, please consult your nearest regional dealer/distributor or check our website at www.firstdegreefitness.com
Siphon [25] · Siphon valve

Long Term Water Treatment and Basic Operation
Long Term Water Treatment:
Do not use any water treatment other than the tablets supplied with this unit. For replacement tablets, contact your local First Degree Fitness distributor.
Water treatment schedules for the FLUID ROWER will vary according to the fluid tanks exposure to sunlight, but expect 8-12 months near a bright, sunlit window and 2 years or more for a darker location. At the point of finding the water slightly cloudy, add a Water Treatment Tablet.
Vertical Storage: The FLUID ROWER can easily be stored in a vertical position. For safety, choose a suitable location, such as a corner of a room. It is recommended that something soft (such as carpet or a small towel) be placed under the rowing pulley of the unit to avoid chipping or floor damage. Note: Move with caution as the unit is heavy. Pick up from back and pull at 45 degree angle.
Level Indicator Resistance:

The level of resistance is determined by the level indicator located on the front of the tank. Level one indicates lightest re- sistance, level sixteen represents heaviest resistance. Allow three to four strokes after adjusting resistance handle to allow the water to move to the correct location.

Adjust Footplates The Slider Footplate accommodates most foot sizes, and is designed to keep your feet securely in place as you row. TO ADJUST: Lift the top of the footplate from the mounting peg and slide vertically between 1-6 to suit your foot length. Secure by hooking the footplate back onto the mounting peg and pushing down firmly to lock it into position. Place feet on the foot plates and tighten the foot straps to ensure your feet sit firmly against the heel captures. Note: The heel capture should bend to allow your foot to pivot naturally as you row.

or without the sliding portion of the Slider Footplate locked into position!
Integrated Performance Monitor [IPM] Operation
Quick start: Provides instant workout information. Just start training to activate. You can choose to change UNITS displayed


LEVEL: Adjustable from 1-16. Match LEVEL number with resistance level on the Fluid tank.
Mounting Pegs · Foot strap · Slide

There are six phases to completing a rowing stroke

For more information on correct rowing technique and workout tips visit our website www.firstdegreefitness.com/indoor-rowing-technique
Stop immediately if you feel faint or dizzy.

The USB connectivity now built in to all new models of FDF Console and IPM allow you
to enhance your exercise experience by connecting to your home PC or Laptop. Using
FDF's own sample applications you can exercise while enjoying your favorite movies.
NetAthlon 2 XF for Rowers lets you race with other Internet connected rowers in a
Virtual Reality 3D environment or train solo.
1.Download and Install the USB Device Driver (CDM2xxxx_Setup.exe for 32 and 64 bit
Windows 7/Vista/XP) from the FDF Website.
2.Download and Install the Sample USB Applications from the FDF Website
Download and Install NetAthlon 2 XF for Rowers from.
http://www.webracing.org/downloads.htm
- The USB Connector is located on a flying lead at the rear of the IPM, along with the
Sensor and Heart Rate Monitor Connectors.
- Connect to a Laptop or PC using a standard USB cable, you may need to wait while
Windows starts the USB Device Driver.
information refer to our website at www.firstdegreefitness.com

All preventive maintenance activities must be performed on a regular basis. Performing routine preventive maintenance actions can aid in providing safe, trouble-free operation of all First degree fitness equipment.
First degree fitness is not responsible for performing regular inspection and maintenance actions for your machines. Instruct all personnel in equipment inspection and maintenance actions and also in accident reporting and recording.
First degree fitness representatives are available to answer any questions that you may have.
Wipe Seat Rails with lint free cloth. Spray seat rails with a light coat of silicone spray.
Seat and Seat Rails Weekly.
Frame Weekly. Wipe down with lint free cloth.
Follow instructions as specified in the “Water Treatment” section of this manual.
Tank and Water Treatment
12 months to 2 years.
Check every hundred hours for correct tension and for signs of wear.
The Bungee Cord should last for many years. If a bungee cord change is required, please follow the instructions provided in the “Changing the Bungee Cord” section of this manual.
The Rowing Belt should provide many years of trouble free use. If a Rowing Belt change is required, please contact your local service representative or go online at www.firstdegreefitness.com for further details.
Check every hundred hours for correct tension and for signs of wear.
Check regularly for proper tension.
Tighten until taut. See Basic Operation page for details
Bungee Cord · Rowing Belt · Frame Tension Cable

Fault Probable Cause Solution
Water changes color or becomes cloudy.
Rower is in direct sunlight or has not had water treatment.
Change rower location to reduce direct exposure to sunlight. Add water treatment or change tank water as directed in the water treatment section of this manual. Consider using distilled water to refill tank.
Rowing stroke return is too light.
Bungee not under enough tension.
Open rear Perspex cover, cut bungee tie wrap . Tighten by small increments using the bungee tie off tab point and test tension by allowing the rowing handle to return to its furthest point forward while still having some slight tension. Note light fraying of the bungee cord is normal.
Rower rocks from side to side when sitting on floor
Front/Rear frame levelers need adjusting
Adjust the front two frame levelers or rear leg levelers until stability is reached. Note: It is normal for the lower rear leveler to rest slightly off the floor.
Front of rower lifts slightly during vigorous rowing.
Lower rear frame leveler too high.
Check to see that frame tensioning bolt is tightened properly. Lower rear frame leveler should be approx. 5mm off the ground.
Computer screen illuminates, but does not register when rowing.
Loose or failed connection/Sensor gap too wide (see erratic computer display).
Check that the computer lead is connected properly. If connected properly check sensor gap. Contact your local service center if this fails to address the problem.
The Rower comput- er does not illumi- nate after battery installation.
Batteries installed incorrectly or need replacing.
Reinstall batteries in correct position and try again. If the LCD screen fails to illuminate, try rotating the batteries slightly in the computer. If this fails, contact your local service center.
The Rower comput- er display is erratic while displaying SPM and 500meter times.
Gap between sensor and magnetic ring is too wide.
Adjust sensor location using rear sliding adjustment located inside rear Perspex cover.
Excessive frame flex during hard rowing.
Loosen frame tension cable Retaining Nut and tighten cable until taut.
Cable is too loose
Frame Tension

4. Next, remove the Magnetic Ring. To loosen the Rear Mainshaft Bolt holding the magnetic ring in place, it is necessary to keep the Mainshaft and impeller assembly from turning with the bolt. Open the yellow tank plug, and insert a wrench wrapped in a lint free cloth (to protect the electroplating finish on the blades) to catch the impeller blade and allow the Rear Mainshaft Bolt to be loosened as shown below right with a 6mm Allen key. Caution: Do not allow a dissimilar metal to
Disconnect sensor lead before removing cover completely.

directly contact the impeller blade. Premature rusting could occur . Cover any tool inserted the tanks with a lint free cloth and keep fingers clear. WARNING : Do not insert fingers into tank!



Rear Mainshaft Bolt and Magnetic Ring








C Clip · Remove Replace · Re-Wrapping



Finally, reattach the Sensor Lead and replace the Perspex rear cover.



C Clip

This product is designed and constructed for use in any Health Club / Fitness Studio application. First Degree Fitness Limited warrants that the Fluid Rower E316, S6 Laguna and Vortex VX-2 (model FR-E316 & S6 & VX-2), purchased from an authorised agent and in its undamaged original packaging, is free from defects in materials and workmanship. First Degree Fitness Limited or its agent will, at their discretion, repair or replace parts that become defective within the warranty period, subject to the specific inclusions and exclusions below. Metal Frame – 10 Year Limited Warranty First Degree Fitness will repair or replace the metal Main Frame of the Rower should it fail due to any defect in materials or workmanship within 10 years of the original purchase. Warranty does not apply to frame coating. Polycarbonate Tank & Seals – 3 Year Limited Warranty First Degree Fitness will repair or replace the polycarbonate tank or seals should they fail due to any defect in materials or workmanship within 3 years of the original purchase. Mechanical Components (of a non-wearing nature) – 2 Year Limited Warranty First Degree Fitness will repair or replace any mechanical component should it fail due to any defect in materials or workmanship within 2 years of the original purchase. All Other Components (of a wearing nature) – 2 Year Limited Warranty First Degree Fitness will repair or replace any component should it fail due to any defect in materials or workmanship within 2 year of the original purchase. Specific Inclusions
Bungee recoil cord, belt and pulley Hand grips & foot straps Seat All pulleys, rollers & bearings All rubber components Computer & speed sensor (excluding replaceable batteries) All drive belts Aluminum seat rails Sliding footplates General Exclusions
Damage to the finish of any part of the machine Damage due to neglect, abuse, incorrect assembly or use of the machine Any charges for freight or customs clearance associated with the return or dispatch of parts Any damage to or loss of goods during transport of any kind Any labour cost associated with a warranty claim General Conditions
The serial number of the machine must be correctly registered with First Degree Fitness Limited or one of its appointed distributors First Degree Fitness Limited reserve the right to examine any part where replacement is claimed under warranty Warranty period applies only to the original purchaser from the date of purchase and is not transferable The product must be returned to your place of purchase in original packaging with transportation, insurance and associated charges paid for by you and risk of loss or damage assumed by you First Degree Fitness makes no other warranties except as stated here and expressly disclaims all warranties not stated in this warranty. Neither First Degree Fitness nor its associates shall be responsible for incidental or consequential damages Manufacturer's warranty automatically commences upon sale of the product to end user or upon the expiration of one (1) year from month of manufacture, whichever occurs first



NOUS CONTACTER Pour le soutien à la clientèle, veuillez visiter firstdegreefitness.com/support TAÏWAN T: +886 3 478 3306 764 Chung Shan South Rd Yangmei Taoyuan Taiwan R.O.C.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Water changes color or becomes cloudy. | Rower is in direct sunlight or has not had water treatment. | Change rower location to reduce direct exposure to sunlight. Add water treatment or change tank water as directed in the water treatment section of this manual. Consider using distilled water to refill tank. | p.27 |
| Rowing stroke return is too light. | Bungee not under enough tension. | Open rear Perspex cover, cut bungee tie wrap . Tighten by small increments using the bungee tie off tab point and test tension by allowing the rowing handle to return to its furthest point forward while still having some slight tension. Note light fraying of the bungee cord is normal. | p.27 |
| Rower rocks from side to side when sitting on floor | Front/Rear frame levelers need adjusting | Adjust the front two frame levelers or rear leg levelers until stability is reached. Note: It is normal for the lower rear leveler to rest slightly off the floor. | p.27 |
| Front of rower lifts slightly during vigorous rowing. | Lower rear frame leveler too high. | Check to see that frame tensioning bolt is tightened properly. Lower rear frame leveler should be approx. 5mm off the ground. | p.27 |
| Computer screen illuminates, but does not register when rowing. | Loose or failed connection/Sensor gap too wide (see erratic computer display). | Check that the computer lead is connected properly. If connected properly check sensor gap. Contact your local service center if this fails to address the problem. | p.27 |
| The Rower comput- er does not illumi- nate after battery installation. | Batteries installed incorrectly or need replacing. | Reinstall batteries in correct position and try again. If the LCD screen fails to illuminate, try rotating the batteries slightly in the computer. If this fails, contact your local service center. | p.27 |
| The Rower comput- er display is erratic while displaying SPM and 500meter times. | Gap between sensor and magnetic ring is too wide. | Adjust sensor location using rear sliding adjustment located inside rear Perspex cover. | p.27 |
| Excessive frame flex during hard rowing. | Frame Tension Cable is too loose | Loosen frame tension cable Retaining Nut and tighten cable until taut. | p.27 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.