PREDATOR E620ST


WELCOME TO YOUR PREDATOR E620ST Congratulations on your purchase – the Predator is constructed for high intensity, power- ful workouts. The unit’s step on design, small footprint and wide foot plates provide in- stant access and total stability as power is transmitted from the ground up. Perfect for circuit training as well as CrossFit, the Predator offers a bullet proof plat- form to achieve an entire body workout allowing integrated movement of the user’s core and upper body. Its bi-directional function offers huge advantage for rehabilitation pur- poses, enabling reciprocal muscle group balance and support of major joints. Whether you are a veteran, athlete or somewhere in between, the Predator is designed to target strength, endurance, intensity, agility, stability, flexibility and balance through each workout.
Visit our website for workout tips and product support. PRODUCT REGISTRATION AND SERIAL NUMBER TO VALIDATE WARRANTY SUPPORT, RECORD YOUR UNIQUE PRODUCT PURCHASE BE- LOW AND SAVE YOUR ORIGINAL RECEIPT.
SERIAL NO.
TO REGISTER YOUR PRODUCT WARRANTY ONLINE OR UNDERSTAND THE TERMS OF YOUR WARRANTY VISIT WWW.FIRSTDEGREEFITNESS.COM/SUPPORT If you are making a warranty claim, please contact your local FDF Dealer In the first in- stance.


All users should read the operating instructions contained within this manual and under- stand how to use the Predator E620ST before use. Visit www.firstdegreefitness.com for additional information on technique and training instruction. NOTE THE FOLLOWING SAFETY PRECAUTIONS:
If you experience any pain or dizziness while exercising, stop immediately and consult your physician. Warm up before undertaking any strenuous exercise.


Bi-directional rotation for complete muscle engagement
56.5kg (124.5lbs)
Fixed crank arm for robust dura- bility.
Minimum Safe Operating Surface Area: 1,910mm x 1,350mm Dimensions: 1,326mm L x 736mm W x 1,242mm H Maximum User Weight:
20 levels of Variable Fluid Resistance at the turn of a dial-perfect for multi-user facilities.
Wide footplates for optimum power and stability driven workouts from the ground up.
Footprint:
Instant step-on access with nothing to adjust.
Compact footprint with built-in transport wheels

150kg (330lbs) · 1,340mm x 740mm · for




5 7 8 9 10 6
12 13 14 15 16 17

a) Place the lower frame [2] on a flat surface. b) Lift the upper frame[1] carefully and inser slowly into the low-
er frame’s [2] bracket.



a) Secure the upper frame to the lower frame using the M10 x
130mm Bolt [5] and M10 Nylock Nuts[9] REQUIRED 4xM10x130mm
Bolts [5] 8xM10 Washers

Nuts[9] Multy-tool [12] 8mm Allen Key
M10 Washer M10 Nylock Nut


a) Secure either side of bracket using the 2xM8x15mm [6] and
REQUIRED 2xM8x15mm [6] 2xM8 Washers
M8 Washers [8], tightening with the 6mm Allen Key [11].
[8] 6mm Allen Key

M8x15 Bolt M8 Washer

a) Identify the right and left handle shafts. There is a ‘R’ or ‘L’
REQUIRED 1 x Left Handle
marked on each handle shaft. NOTE: Improper installation will result in uneven handle adjustment. b) Use the 6mm Allen Key to disassemble the M8x15mm Bolt
Kit [3], includes 1xM15 Washer & 1xM8x15mm Bolt 1 x Right Handle
and M15 Washer on each handle
Kit [4], includes 1xM15 Washer & 1xM8x15mm Bolt 6mm Allen Key






c) Secure right and left handle onto
d) Re-assemble the M8 Bolt and M15
corresponding crank arms by screw- ing the handle counter- clockwise using the Multi-tool [12]
Washer onto the handle on each side using the 6mm Allen Key [11]


to crank arm. This is a type of thread locker, which once in contact with the crank arm will cause threads to activate. Note: Allow 15 minutes for the thread locker to activate before first time use. Check pedal tightness periodi- cally thereafter with a 15mm wrench. DO NOT USE IF NOT TIGHT.
ADJUST IMPELLER POSITION. IT IS RECOMMENDED TO USE THE END OF THE HOSE SHOULD THE IMPELLER REQUIRE ADJUSTMENT.
a) Filling requires a large bucket (not supplied) and the supplied water funnel and
hose. Filling will take approximately 8 litres of water. b) Open the yellow fill plug on the back of tank and insert hose (rotating the im-
peller slightly may be necessary to allow the hose to pass). In areas where tap water quality is known to be poor, FDF recommends the use of distilled wa- ter. c) Move the tank adjuster handle to level 20 and begin filling. Do not fill the tank
higher than the level indicator on the front of the clear shell. d) Once filling is complete follow the water treatment schedule below.

Yellow tank fill plug
a) Add One Water Treatment Tablet per full tank.
Do NOT, UNDER ANY CIRCUMSTANCE, USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED YOU’RE YOUR UNIT. Your unit purchase includes 4xWater Treatment Tablets, which is sufficient for several years of use.
Water Funnel and Hose sup- plied with unit
Multi-tool

Changing resistance on your Predator E620ST is simple. The level of resistance is determined by the level indicator located on the side of tank. Level one indicates lightest resistance, level twenty represents heaviest resistance. The tank’s variable fluid resistance technology ensures an instant catch and constant resistance throughout the pedaling.
Be sure to set the level +/- buttons on the E620ST computer to match the re- sistance setting on the fluid tank lever for accurate readings. Allow three to four seconds after adjusting resistance handle for the correct resistance level to be achieved.
a) Stand on the foot plates with feet
shoulder width apart (feet, hips and shoulders should be square to the machine). b) Grip ergonomic handles comforta-

bly and commence rotating the cranks forward or backward. c) Stand close enough so that when
either arm is at its furthest point away from you, your arm is com- fortably extended and your shoul- ders are still square. d) If you are seeking a ‘full body’
workout, try applying pressure from your hips and feet to engage a fully integrated crank. e) To stop the crank action, gradually
slow motion and apply tension in the opposite direction.
SUPPLIED WITH YOUR UNIT.
The amount of time between water treatments can vary greatly depending on your unit’s location and exposure to sunlight. Typically you can expect to treat your tank water every 12-24 months. If water becomes discoloured or shows signs of algae / bacterial growth simply add one Water Treatment Tablet.
Please consult your nearest regional dealer to arrange the purchase of further treatment tablets or visit
www.firstdegreefitness.com/support for further advice and assistance.

Auto Start: Commence exercise.
Reset all values: Press and hold RESET button for 3 seconds.
Changing Units [KPH/MPH]: Press and hold RESET and LEVEL UP for 5 seconds. Use LEVEL UP to toggle between KPH and MPH. Press RESET once to confirm.
Distance: Each single press of RESET adds 100m distance, up to 1000m then adds 500m.
For over 5 seconds and under 5 minutes:
a)RPM/SPEED/WATT to zero.
b)Distance/TIME values are saved.
c)CAL per hour defaults to Total CAL.
d)A resumption in exercise in less than 5 minutes will resume Distance/TIME from saved values
automatically.

TIME: Auto start elapsed time.
SPEED: Current speed as KPH or MPH.
PULSE: Requires optional receiver and chest strap (sold separately).
RPM: Revolutions per minute at the crank (pedals).
Use the LEVEL UP/ DOWN buttons to align the level with the same level selected on the Fluid Tank Resistance Adjuster handle for accu- rate Distance/ CAL/WATTS.
CAL HOUR: Calories burned per hour at the current Watts. Shows total calories burned when exercise is stopped.
faint, stop exercising immediately. WARNING — This stationary training equipment is not suitable for high
accuracy purposes.

For further information, manuals and warranty requests visit www.firstdegreefitness.com/support
To ensure maximum lifespan and optimal performance follow these steps:


CONTACT US For customer support please visit firstdegreefitness.com/support TAIWAN T: +886 3 478 3306 764 Chung Shan South Rd Yangmei Taoyuan Taiwan R.O.C.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The water tank appears cloudy or tank water has changed colour. | Check to see that your unit has not been positioned in direct sunlight as this can im- pact the water quality. Your tank requires a water treatment every 12-24 months. To treat the water, refer to the section in this manual called “Long – Term Water Treatment” on page 8. | p.12 | |
| I want to drain the fluid tank on my E620ST. | It is recommended to take your unit out- doors, open the yellow fill plug, and lay unit on its side to facilitate draining process. If draining indoors, a container capable of holding 8litres of water will be required. | p.12 | |
| The computer display is erratic and illumi- nates, but does not register with move- ment. | It is possible that there is a loose connec- tion. Check that the computer lead is con- nected properly to the unit. If connected properly check sensor gap. Contact your local dealer if this fails to address the problem. | p.12 | |
| The computer does not illuminate after battery installation. | Reinstall batteries in correct position and try again. If the LCD screen fails to illumi- nate, try rotating the batteries slightly in the computer. If this fails, contact your local dealer. | p.12 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.