Zebra® MM4 Mobile Mount Vehicular Mount for Qln420, QL420 and P4T/RP4T Mobile Printer Series
P1005089 Rev. C January, 2013

The following notices emphasize certain information in the guide. Each serves a special purpose and is displayed in the format shown:
in personal injury.

Introduction
The MM4 Mobile Mount system is designed to integrate a Zebra™ QLn420, QL 420 or a P4T series mobile printer and optionally a Zebra DC/DC power supply into the electrical and mechanical systems of a vehicle. Once installed it will provide intelligent charging capabilities for the printer’s battery and protection from accidental damage to the printer.
The DC/DC modules are supplied separately from the MM4 installation Kit (p/n AK18926-3 for QL 420 & P4T and P1050667-035 for QLn420). They should be installed in accordance with their installation guides and under the supervision of properly trained and qualified personnel.
The installation and safety warnings in this manual pertain only to the mechanical installation of the MM4 mobile mount. Follow them closely to ensure safe, reliable performance of the QLn420, QL 420 or P4T Printer in a mobile environment
It is important that the vehicle’s electrical system be functioning properly. The vehicle’s charging circuit must work properly and vehicle-generated electrical “noise” must be minimized and within specifications.
The vehicle charging circuit must neither undercharge nor over-charge the vehicle battery. Defective ignition wiring, damaged insulation, or faulty vehicle electrical components can cause electrical noise and excess electrical noise can be severe enough to defeat the electrical filtering that is built into the printer. When this happens, computers and printers can behave unpredictably.

The MM4 Mobile Mount allows you to mount a QLn420, QL 420 or P4T printer into virtually any vehicle. A separately supplied DC/DC power supply appropriate to each printer model can provide a source of power to run and charge the printer’s battery from the vehicle’s electrical system.
Installation of the DC/DC power supply is covered in the Installation Guide supplied with each system.
In most installations, the power cable is wired to the vehicle’s battery power system indirectly through a power take-off point. Some models of the DC/DC supplies offer the option of accessing input power from the vehicle’s cigarette lighter or power adapter.
Since each situation or equipment type may pose unique requirements, mounting hardware selection and mechanical installation shall be the responsibility of the installer. Zebra recommends using self-locking (ESN) nuts, bolts, and/or lock washers for installing the mount. The mount is pre- drilled for 1/4” (M6) mounting hardware.
Your tasks are to:
Decide where you will mount the printer, then proceed with the following instructions.
Installing a Terminal When you are installing the MM4 Mobile Mount, you may also be installing a terminal at the same time. Follow the terminal manufacturer’s instructions for installing their unit. If the printer and terminal are linked together with a data cable it typically should be no longer than six (6) feet (183 cm).
Some installations may require the terminal and printer to communicate via radio frequency (RF) rather than cables.
Plan your installation with these considerations in mind, and locate the printer so that the operator can easily load printing media and operate the printer’s controls.

The MM4 Mobile Mount provides two basic mounting options, to allow maximum flexibility in location. The DC/DC module is shipped separately and is mounted external to the Mobile
Mount, depending on the individual
location’s requirements.
It is important to leave a free zone around the printer to allow loading of paper and routine cleaning of the print head. Refer to Figure 2. In addition, the Mobile Mount allows for some rotation of the printer to allow the best positioning for the operator. Extra clearance should be provided for this movement if it is desired in the installation.
“H”
Vertical Mounting (numbers in italics are in cm.)
“W”
Horizontal Mounting (numbers in italics are in cm.)
*Includes minimum dimension to allow access to controls.
it will not interfere with the operator during normal use, nor have the potential to cause injury in case of an accident.
Figure 1 Standard Mounting Configurations (AK18926-3 shown with QL 420. Also used with P4T))


Figure 2 Horizontal and Vertical Mounting D etails (QL 420 illustrated)
Use a 1/4” (6 mm) drill bit to make mounting holes. Secure the mount with nuts, bolts, and lock washers.
Refer to Figure 2 for details on mounting dimensions. The mounting bracket (Figure 3) can also be used as a template for locating mounting holes on the vehicle. Note that a clearance of .31” (7.8 mm) must be left on either side of the Mounting Bracket for mounting hardware. The mounting dimensions in Figure 1 reflect this.

11.00” (27.94 cm)
11.00"
8.63” (21.92 cm)
8.63"
2.00” (5.08 cm)
1.82” typ. (4.62 cm) .31” (7.8 mm)
2.75” (6.98 cm)
2.01" 2.75" 1.82" 0.31"
ø.31” x 4 (7.8 mm)
0.31" Dia. x4
31” typ. (7.8 mm
0.31"
Figure 3 Mounting Bracket H ole Layout (not to scale)
when using in the horizontal configuration.
Hardware to secure the Mobile Mont to the vehicle is not supplied in the kit. Recommended
fasteners are 1/4” (6 mm) diameter hex head or socket head bolts with flat washers, lock washers, nuts and/or locking nuts.


Printer Preparation Prepare the printer for installation by doing the following:
QLn420 only:
QL 420 only:

Remove Carrying strap.
Replace bushings and screws after removing carrying strap.
Remove Carrying Strap by unscrewing corner screws
Remove Belt Clip by removing (2) screws.
QLn420, QL420 and P4T Printers:
Metal Belt Clip · Remove (2) screws · Docking Contacts Plug

Installing the Printer The QLn420, QL 420 or P4T Printer can now be installed in the Mobile Mount.
QLn420:
Peel adhesive backer from the (4) Foam Washers and apply to the Mounting Plate over the
printer mounting holes as indicated in Figure 6. Secure the printer to the Mobile Mount Bracket with (2) #6-32 x 3/8”Screws, (2) #6-32 x1/2” Screws, Lock Washers and Flat Washer. Do not exceed an installation torque of 7 in/lb. [.79 Nm] on these screws.
Peel adhesive backer from the (4) Foam Washers and apply to the Mounting Plate over the printer mounting holes as indicated in Figure 7. Secure the printer to the Mobile Mount Bracket with (4) #8-32 x 3/8” Screws, Lock Washers and Flat Washers. Do not exceed an installation torque of 7 in/lb. [.79 Nm ] on these screws.
Peel adhesive backer from (2) Foam Washers and apply to the Mounting Plate over the printer mounting holes as indicated in Figure 7. Secure the printer to the Mobile Mount Bracket with (2) #8-32 x 3/8” Screws, Lock Washers and Flat Washers. Do not exceed an installation torque of 7 in/lb. [.79 Nm ] on these screws.

Washer, Foam (p/n AT17342-1 4 p/u for QLn420*) *4th Mounting H ole not visible
Data I/O Cable from terminal
Plug from D C/DC module
1/4-20 x 1/2” Bolt, supplied with Mobile Mount Kit (p/n TH-SK2007)

Washer, Foam (p/n AT17342-1 4 p/u for QL 420*) *4th Mounting H ole not visible

1/4-20 x 1/2” Bolt, supplied with Mobile Mount Kit (p/n TH-SK2007)
Washer, Foam (p/n AT17342-1 2 p/u at lower set of mounting holes for P4T)
Install the Output Cable from the DC/DC Module QL 420:
Plug the output voltage cable from the DC/DC module into the battery pack connector of QL 420. (Note: In some installations it may be easier to plug the charger cable into the battery pack prior to securing the Printer to the Mobile Mount.) If desired, you can use one of the supplied cable clamps and a #6-32 x 1/4” screw to hold the cable in position.
QLn420 and P4T: Plug the output voltage cable from the DC/DC module into the DC power connector on the Qln420 and P4T. (Refer to the QLn Series and P4T User’s Manuals for more information.)
Attaching the Fanfold Bin If the printer will be using fanfold media, you must install the fanfold bin to the Mobile Mount. Hook the lip on the back of the tray to the corresponding “hooks” on the mobile Mount. Install a 1/4- 20 Hex head screw to the back of the center bar on the Mobile Mount which supports the fanfold bin and tighten it to secure the bin.
continued

Loading Media Follow the loading procedures found in the QLn Series, QL 420 or P4T User’s Guide. Note that if you are using Fanfold media, you should install the Fanfold Spacer (p/n BA16625-1) between the printer’s media supports. The Spacer is included with the MM4 Mobile Mount Kit.
Printer Removal: There is no need to remove the printer from the Mobile Mount during normal use and cleaning. All access doors and controls can be reached with the printer secured in the mount.
To remove the printer for servicing or repairs:
If you are communicating data to the QLn420, QL 420 or P4T with a cable you must connect a “Data I/O” cable between the terminal and the printer. If desired, you can use one of the supplied cable clamps and a #6-32 x 1/4” screw to hold the cable in position. Consult the factory for information on the various I/O data cables offered by Zebra for use with a variety of widely used terminals.
DC/DC Modules for use with MM4
DC/DC Module Location Locate the DC/DC Module in a location convenient to the printer. Follow these guidelines:

QL420: Plug the output cable from the module to the battery connection on the printer.
(Refer to the QL 420 User’s Manual for more information.) It may be easier to plug in the charger connector before mounting the Printer to the Mobile Mount bracket.
P4T/RP4T: Plug the output cable from the module into the power connection on the printer.
(Refer to the P4T User’s Manual for more information.) It may be easier to plug in the module output connector to the printer before mounting the Printer to the Mobile Mount bracket.
the indicator lights on the DC/DC module are lit and it is functioning properly.
RCLI series only: Refer to Table 1 in the RCLI Mobile Charger Installation Guide for indicator display information. Connecting a Terminal
If you are also installing a terminal in the vehicle, you normally must run two separate cables from the vehicle power source: one to the printer and one to the terminal. The terminal power cable must be either supplied by the terminal manufacturer or fabricated by the installer.
It is the installer’s responsibility to determine the suitability of running a terminal from the vehicle’s battery.
The following list of parts is included with the MM4 Mobile Mount Kit. They are intended for use in the installation of the QLn420, QL 420, P4T, and/or printer and routing power and data I/O cables.

NOTES: Mounting hardware for securing the Mobile Mount to the vehicle is not supplied in the kit. Recommended fasteners for the Mobile Mount are 1/4” (6 mm) diameter hex head or socket head bolts with flat washers, lock washers, nuts and/or locking nuts. Recommended fasteners for the RCLI series D C/DC modules are #6-32 (M3) bolts, flat washers and lock washers
Connect the Printer

Printer Technical Support When calling with a specific problem regarding the printers used in conjunction with the MM4 Mobile Mount, please have the following information on hand:
For on-line product support and the most recent versions of downloadable user documentation, firmware and software utilities, go to the Zebra Web site: www.zebra.com
In the Americas contact
Regional H eadquarters Technical Support Customer Service D ept.
Zebra Technologies Corporation 475 H alf D ay Road, Suite 500 Lincolnshire, Illinois 60069 USA Phone: +1.847.634.6700 or +1.866.230.9494 Fax: +1.847.913.8766
T: +1 877 275 9327 F: +1 847 913 2578 Hardware: ts1@zebra.com Software: ts3@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +1 877 275 9327 E: clientcare@zebra.com
In Europe, Africa, the Middle East, and India contact
Regional H eadquarters Technical Support Internal Sales D ept.
Zebra Technologies Europe Limited Dukes Meadow Millboard Road Bourne End Buckinghamshire SL8 5XF, UK T: +44 (0)1628 556000 F: +44 (0)1628 556001
T: +44 (0) 1628 556039 F: +44 (0) 1628 556003 E: Tseurope@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +44 (0) 1628 556032 F: +44 (0) 1628 556001 E: cseurope@zebra.com
In the Asia Pacific region contact
Regional H eadquarters Technical Support Customer Service
Zebra Technologies Asia Pacific Pte. Ltd. 120 Robinson Road #06-01 Parakou Building Singapore 068913 T: +65 6858 0722 F: +65 6885 0838
T: +65 6858 0722 F: +65 6885 0838 E: (China) tschina@zebra.com All other areas: tsasiapacific@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +65 6858 0722 F: +65 6885 0836 E: (China) order-csr@zebra.com All other areas: csasiapacific@zebra.com
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA T: +1 847.634.6700 or +1 800.423.0442
p. 13 of 13 P1005089 rev. C
China
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.