1241 Bundy Boulevard, Winona, Minnesota USA 55987 Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507 http://www .watlow .com Please consult this user’s manual when you place your new DIN-A-MITE in service. It contains all the necessary information to mount and wire it into the application.
Specifications 2 W A TLOW DIN-A-MITE S tyle D User ’s Manual Operator Interface • Command signal input and indication light • Alarm output and indication light Amperage • Single-phase, 80A output maximum at 50°C (122°F) into a resistive load.
DIN-A-MITE Style D , solid-st ate power controller Part Number D D 1 0 - __ __ __ __ - __ __ __ __ Phase 1 = Single-phase, one controlled leg Cooling and Current Rating 0 = Natural convection; current rating 80A @ 50°C (122°F) Note: See the output rating curve for the current rating at other temperatures.
4 W A TLOW DIN-A-MITE S tyle D User ’s Manual After removing all power , use a 7/16-inch nut driver to remove fuse mounting nuts. T orque to 4.52 Nm (40 in-lb). ç WARNINGS: Ó 1 WARNING: Use National Electric (NEC) or other country-specific standard wiring practices to install and operate the DIN-A-MITE.
W A TLOW DIN-A-MITE S tyle D User ’s Manual 5 Single-Phase Output and Input Wiring L1 2 1 Limit Control Contacts (if required) L1 for all voltages Alarm or Current Transformer Output Alarm or Current Transformer Output (Model Number-Dependent) Heater 4 to 20mA input: (+) (-) 4.
Declaration of Conformity DIN-A-MITE ® “D” Power Controller W atlow Winona, Inc. 1241 Bundy Blvd. Winona, MN 55987 USA Declares that the following product: Designation: DIN-A-MITE® “D” Power Control Model Numbers: DD10 – (02, 24, 48 or 60)(C0, C1, C2, K1, K2, K3, F0 or F1) – (0, C, D, H or S)(followed by any 3 numbers or letters.
W A TLOW DIN-A-MITE S tyle D User ’s Manual 7 An external EMI filter must be used in conjunction with the DIN-A-MITE for loads in excess of six amperes (6 A) at 150 to 250 kHz. Without a filter applied, the DIN-A-MITE does not comply with the conducted emissions standard for loads more than 6 A at 150 to 250 kHz.
The W atlow DIN-A-MITE is warranted to be free of defects in material and workmanship for 36 months after delivery to the first purchaser for use, providing that the units have not been misapplied. Since W atlow has no control over their use, and sometimes misuse, we cannot guarantee against failure.
An important point after buying a device Watlow Electric Style D (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Watlow Electric Style D yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Watlow Electric Style D - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Watlow Electric Style D you will learn all the available features of the product, as well as information on its operation. The information that you get Watlow Electric Style D will certainly help you make a decision on the purchase.
If you already are a holder of Watlow Electric Style D, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Watlow Electric Style D.
However, one of the most important roles played by the user manual is to help in solving problems with Watlow Electric Style D. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Watlow Electric Style D along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center