Instruction/ maintenance manual of the product X-9 Viking Access Systems
Go to page of 36
X - 9 vehicular gate operator installation instructions and safety information CLASS I, CLASS II, CLASS III and CLASS IV LISTED 18TC UL 325 UL 991 Viking Access Systems T 800.
TECHNICAL SUPPOR T 1 800 908 0884 i P AR TS DIA GRAM P AR TS DIA GRAM 1 9 4 5 12 2 6 10 1 1 (2) 7 8 3 I tem Description P art No. 1 Cover , Plastic VAX9PC 2 Motor/Gear Unit VAX9 3 Chassis, Motor/Gear .
TECHNICAL SUPPOR T 1 800 908 0884 1 T ABLE OF CONTENTS T ABLE OF CONTENTS P arts Diagram/P arts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions . . .
TECHNICAL SUPPOR T 1 800 908 0884 2 W ARNING - Not following these instructions may cause se vere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION IMPOR T ANT SAFETY INSTRUCTIONS W ARNING – T o reduce the risk of severe injury or death: 1.
TECHNICAL SUPPOR T 1 800 908 0884 3 W ARNING - Not following these instructions may cause se vere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION 6.
TECHNICAL SUPPOR T 1 800 908 0884 4 W ARNING - Not following these instructions may cause se vere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION GENERAL SAFETY PRECA UTIONS The following precautions are an integral and essential part of the product and must be supplied to the user .
TECHNICAL SUPPOR T 1 800 908 0884 5 5 UL325 Gate Operator Classification TERMINOLOGY T ERMINOLOGY GLOSSAR Y RESIDENTIAL VEHICULAR GA TE OPERA TOR CLASS I – A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
TECHNICAL SUPPOR T 1 800 908 0884 6 IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION Gate in Open Position Photo Beam Unit Reflector Potential Entrapment Area (Shaded) Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 7 Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 8 Audible Alarm Reset Switch Installation W ARNING - Not following these instructions may cause se vere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION W arning Placard Installation Manual Stop Button 5' Minimum STOP Radio Station Mag.
TECHNICAL SUPPOR T 1 800 908 0884 9 IMPOR T ANT INST ALLA TION INFORMA TION I MPOR T ANT INST ALLA TION INFORMA TION Specifications This is NOT a pedestrian gate operator 14’ maximum gate length 600 pounds maximum gate weight Do NOT Install the gate operator to lift gates Locate Control Buttons: 1.
TECHNICAL SUPPOR T 1 800 908 0884 10 PLAN OF INST ALLA TION - OPEN INSIDE P LAN OF INST ALLA TION - OPEN INSIDE Inside Outside Inside Outside Gate in Closed Position Gate in Closed Position 90 ° Opening A : 15-3/4" Max. C : 23-1/2" C : 19-1/2" F : 15-1/2" Min.
TECHNICAL SUPPOR T 1 800 908 0884 11 The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
TECHNICAL SUPPOR T 1 800 908 0884 12 16 STEP 1 Check the integrity of the gate structure and sufficiently sturdy such as pivot points are properly lubricated and surfaces are free of rust. a) Remove the Motor/Gear Assembly from its pa c ka g e. NOTE - The cover is not secured.
TECHNICAL SUPPOR T 1 800 908 0884 13 17 STEP 6 With the cover off, perform the Manual Release procedure as shown at the bottom of page 7. The gate can now be moved manually . Ensure that the gate and gate operator move freely . Once it is determined the operator will work properly , remove the operator and complete the welding process.
TECHNICAL SUPPOR T 1 800 908 0884 14 18 STEP 8 A. Loosen the screws on the limit switch cams and position the cams to the desired locations. There are additional holes provided in case of a wide or tight angle of opening or closing. B. Move the gate manually and ensure that the limit switch gets actuated at the desired open and closed position.
O r a n g e Y e l l o w B l u e B l a c k B r o w n R e d To Limit Switches To Motor Wire Lead From Control Box TECHNICAL SUPPOR T 1 800 908 0884 15 The Limit Switches are wired as shown Limit S.
TECHNICAL SUPPOR T 1 800 908 0884 15 16 CONTROL BO X INST ALLA TION C ONTROL BO X INST ALLA TION 2. P osition the control box in the desired place and mark the mounting holes. Prepare the holes to receive the anchors/fasteners. 15" Standard 17" Industrial Depth: 6.
TECHNICAL SUPPOR T 1 800 908 0884 17 ELECTRICAL INST ALLA TION E LECTRICAL INST ALLA TION Tips for proper ground installation A good ground in a gate operator installation will minimize or prevent damage to the operator cause by natural events such as lightning strik es.
TECHNICAL SUPPOR T 1 800 908 0884 18 Connect the wires from the motor unit to the terminal block mounted next to the control board. Match wire colors to the terminal block.
TECHNICAL SUPPOR T 1 800 908 0884 19 Using the connectors provided insert the wires from the motor units as shown in the diagram below . Insert the connectors in the proper receptacles on the Master/Slave Control Board. The ‘Slave’ gate opens first using the Overlap Delay (see page 28).
Inside Outside Exit Loop Inside Reopen Loop Center Loop Outside Reopen Loop Inside Outside 5' 5' 5' A A 5' Gate in Open Position Inside Reopen Loop Center Loop Outside.
TECHNICAL SUPPOR T 1 800 908 0884 21 VEHICULAR LOOP DETECTOR INST ALLA TION V EHICULAR LOOP DETECTOR INST ALLA TION Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loo.
ACCESSOR Y CONNECTIONS A CCESSOR Y CONNECTIONS TECHNICAL SUPPOR T 1 800 908 0884 22 V ehicle loop detectors must be installed to decrease the possibility of vehicle entrapment on the gate (see page 20).
TECHNICAL SUPPOR T 1 800 908 0884 23 ACCESSOR Y CONNECTIONS A CCESSOR Y CONNECTIONS When connecting the Radio Receiver carefully verify the proper connections. The maximum voltage that the control board provides for external accessories is the maximum voltage of the battery , which is about 28 volts.
TECHNICAL SUPPOR T 1 800 908 0884 24 M M - - 2 2 ™ VIKING ELECTROMA GNETIC LOCK V IKING ELECTROMA GNETIC LOCK This Magnetic Lock is an OPTIONAL ACCESORY available from Vikin g A cces s Syst ems.
TECHNICAL SUPPOR T 1 800 908 0884 25 24 The guard station provides control of the gate operator to open, stop and close the gate. All three switches must be Normally Open type of switch, and can share the same common (ground). Place the control switch bo x within sight of the gate, away from moving parts of the gate and out of reach of children.
TECHNICAL SUPPOR T 1 800 908 0884 26 25 Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 27 27.
TECHNICAL SUPPOR T 1 800 908 0884 28 28 SPECIAL FEA TURES S PECIAL FEA TURES Inside Outside Opens First Slave Unit Master Unit MAG LOCK Mag. Lock UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 29 SOLAR P ANEL INST ALLA TION S OLAR P ANEL INST ALLA TION For Viking Vehicular Gate Oper ators STEP 1 Use a 24V solar panel or two solar panels of 12V in series with a total capacity of 40 W atts.. STEP 3 Replace the existing batteries with a battery pack of 33AHr or greater .
TECHNICAL SUPPOR T 1 800 908 0884 30 (Installed) 1.563" 2.375" 3.187" 6.563" Hinge Pin (0.780" Diameter) Bronze Bushing Set Screw (Can be removed to add lubrication) H H - - 4.
TECHNICAL SUPPOR T 1 800 908 0884 31 29 Gate does not run – Motor Sensor indicator comes ON TROUBLESHOOTING T ROUBLESHOOTING Check all motor connections to be fully engaged. Refer to page 18 and 19. Ensure that the motor connections are: a) Properly connected; b) Tight enough and; c) Match color code.
TECHNICAL SUPPOR T 1 800 908 0884 32 29 TROUBLESHOOTING T ROUBLESHOOTING Gate does not open or close Check all motor connections to be fully engaged. Refer to page 15. Check that limit switches are connected to the common and the normally close position refer to page 15.
TECHNICAL SUPPOR T 1 800 908 0884 33 TROUBLESHOOTING T ROUBLESHOOTING Check that your external devices are working properly Check that your wires from your accessories are: a) Not shorting together b) Not shorting a power line c) Not shorting to metal or earth ground.
X - 9 vehicular gate operator installation instructions and safety information CLASS I, CLASS II, CLASS III and CLASS IV LISTED 18TC UL 325 UL 991 Viking Access Systems T 800.908.0884 • F 949.753.1640 631 Wald - Irvine, CA 92618 vikingaccess.com U L325 and UL991 listed by Underwriter Laboratories (UL).
An important point after buying a device Viking Access Systems X-9 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Viking Access Systems X-9 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Viking Access Systems X-9 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Viking Access Systems X-9 you will learn all the available features of the product, as well as information on its operation. The information that you get Viking Access Systems X-9 will certainly help you make a decision on the purchase.
If you already are a holder of Viking Access Systems X-9, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Viking Access Systems X-9.
However, one of the most important roles played by the user manual is to help in solving problems with Viking Access Systems X-9. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Viking Access Systems X-9 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center