(Up to 7 Single Button Programmable Controls Available)
Safety Beam System must be installed to close door.
For use only with sectional doors. Your Residential Operator comes with a Rail Assembly which is standard for up to a 7 foot high door.
For Answers and Assistance: 1.800.354.3643 or visit www.geniecompany.com
Homelink® is a registered trademark of Johnson Controls Technology Company. Car2U™is a trademark of Lear Corporation.



OVERVIEW OF POTENTIAL HAZARDS
Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on the owner or user of this system to read, understand and implement the information in this manual. If you have questions or do not understand the information presented, contact The Genie Company or an authorized Genie Dealer.
In this section and those that follow, the words DANGER, WARNING, and CAUTION are used to emphasize important safety information.
The word:
The word NOTE is used to indicate important steps to be followed, important considerations, or location of parts.





Things to consider if you are planning to "Do-it-yourself." This operator is designed for use with SECTIONAL doors only. In many cases you will be replacing an existing door operator with a new one, however, if this will be the first operator installed there are some pre-installation issues which need to be addressed. They are as follows: The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a "Do-it-yourself" installation. Any questions should be directed to The Genie Company or an authorized Genie Dealer.
(The issue numbers below refer to the circled numbers in the illustrations on page 5.)
1 Check your ceiling where the power head of your new unit will be mounted. Plan how you will be mounting the power head. It is possible that ceiling joists may not be in the position needed with respect to the garage door operator. It may be necessary to add an additional bracket and fasteners (not included with your new door operator kit). (Refer to Section 2.)
5 You need a 110-120 Volt power supply available. The outlet should be no more than 3 feet from the power head once it is mounted (Refer to Section 5.)
DO NOT USE AN EXTENSION CORD! DO NOT USE A PORTABLE GENERATOR! This product is designed to operate on standard house current. DO NOT USE ALTERNATE POWER SUPPLIES.
2 Check the wall directly above the garage door. The door operator’s header bracket must be securely fastened to this wall. Insure that the structure will provide a strong mounting location.) (Refer to Section 2.)
6 To avoid damage to your door and/or operator, make sure you disable and/or remove any door locks, ropes, and/or cables prior to installing your operator. (Refer to Section 1.)
3 Check to see if the mounting location for the Safety Beam System is clear from obstruction and has a wood surface available for attaching the mounting brackets. The brackets may be attached to concrete if necessary but extra tools and special fasteners (not supplied) will be required. (Refer to Section 4 and 5.)
7 Insure that your door is properly balanced and moving freely. (Refer to Section 2.)
If your door jambs, binds, is improperly balanced or has a broken spring, have it repaired or adjusted by a trained professional service technician. Door springs, cables, pulleys, brackets and associated hardware are under extreme tension and can cause serious injury or death.
aluminum, light-weight steel, fiberglass or glass panels? Additional support bracing must be added to these type doors. If this is the case, please contact the door manufacturer or authorized dealer so that they can furnish you with a "bracing kit." (Refer to Section 2.)
8 (NOT SHOWN) If your garage does not have a separate entry door, you should consider an emergency release kit (GER-2) for installation on your garage door.
To reduce the risk of injury to persons or damage to property - Use this operator only with sectional doors.
Remove · Remove


To reduce the risk of injury to persons or damage to property - Use this operator only with sectional doors.


1/4", 7/16", 3/8" and 1/2" Sockets


with wire (Red LED)
with wire (Green LED)
Safety Beam Source/Sensor Bracket


FASTENERS - Shown Full size (See Parts List below for full description.)
Clevis pin, long 5/16" x 3"
Hex Bolt - 5/16"-18 x 3/4"
Hex Bolt - 5/16"-18 x 1/2"
Shoulder Bolt - 5/16"-18 x 1"

MISSING ANY PARTS? Please call toll free - 1.800.354.3643 DO NOT RETURN TO POINT OF PURCHASE. IMPORTANT! - Information needed when calling


1-PIECE RAIL HARDWARE ASSEMBLED VIEW FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
HIGH SPRING TENSION Can Cause Serious Injury or Death Repairs or adjustments must be made by a trained service person using proper tools and instructions
HIGH SPRING TENSION Can Cause Serious Injury or Death Repairs or adjustments must be made by a trained service person using proper tools and instructions



1. READ AND FOLLOW ALL SAFETY, INSTALL ATION AND OPERATION INSTRUCTIONS. (If you have questions or do not understand an instruction, call The Genie Company or an authorized Genie Dealer.) 2. Install only on a properly balanced sectional garage door. An improperly balanced door could cause severe injury. Have a professionally trained service technician make repairs to cables, spring assemblies, and other hardware before installing the opener. 3. Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener. 4. Where possible, install the door opener 7 feet or more above the floor. For products having an emergency release, mount the emergency release 6 feet above the floor.


RAIL ASSEMBLY: Use a clean, flat surface.

To reduce the risk of injury to persons or damage to property - Use this operator only with sectional doors.
Do NOT run until operator is fully assembled.

1. There are 4 boxes inside the carton. Each box is numbered 1 - 4. Note that some operators will contain the same parts and be packaged with fewer boxes. Carefully remove the three internal boxes (Labeled #1, 2, and 3) and place them on the floor for easy access. (Fig. 1-1). These boxes contain assembly parts and the contents are organized by assembly tasks. For quick reference inside the lid of each box there is a label illustrating the components inside. 2. Remove the motor power head and place it on the floor for later use. Remove box #4 and place it on the floor for later use.

Header Bracket Bag 2
Cause Serious Injury or Death
ments must be made by a trained
roper tools and instructions
instructions.
Bag 3 Bag 1
5/16" Nuts & Bolts
FIG. 1-1 Internal boxes.















CAUTION
Doors made of masonite, lightweight wood, fiberglass, and sheet metal must be properly braced before mounting door operator. Contact door manufacturer or distributor for a bracing kit. The Genie Company is not responsible for damage caused due to improperly braced door.

centerline even with or above top roller
FIG. 2-7 Mounting door Bracket.
centerline of top roller
centerline (Fig. 2-8). – Attach using 3 self-drilling screws for sheet
metal or other light weight material. – Use lag screws (not provided) for solid
wooden sectional doors.
FIG. 2-8 Examples of door bracket positioning.
short clevis pin & cotter pin
rail. • With the arms arranged in this position, fasten arms together using bolts and nuts spaced as far apart as possible (Fig. 2-9).
FIG. 2-9 Attaching door arms.





Wire from power head to wall control.




Verify there is NO power to the operator before installing wall control wires and wall control.

Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the wall control to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.
Use of any other wall control can cause the door to operate unexpectedly and the light not to work. Use only the included wall control.
Separate entry door EXAMPLE ONLY! This is an example of wire routing when NOT pre-wired. Your wire routing may be different.
FIG.3-1 Wall control wire routing
W
FIG. 3-2 Splitting and stripping.


1 2 3 4
1 2 3 4 5 6
previous page). – Insert wire into terminal holes and lightly press in
the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably press in locking clips.) The white wire into #2 terminal hole and striped wire into the #1 terminal hole. – Confirm wire lock by lightly tugging on the wire.
(Power Head With Rear Cover Removed)
FIG. 3-3 Insert wires.
The wire should remain in the terminal hole. • Do NOT install rear cover yet.
FIG. 3-4 Mounting wall control.


FIG. 3-5 Mounting Entrapment warning label.






There should be no electrical power to the operator while installing Safety Beam wires. If you have plugged in the power cord—UNPLUG IT NOW!
FIG. 4-1 Mark door frame.

slide
enough, so tongue of bracket is beyond door, tracks or any door hardware. – If not:
a) Mounting bracket extensions are available
through an authorized Genie dealer. b) Blocks of wood, etc. may be substituted for
FIG. 4-2 Mounting brackets.
FIG. 4-3 Attach sensors to brackets.
RED
GREEN
LED GREEN
LED RED
RED
GREEN
LED
LED
LED
LED
ONE DOOR GARAGE
TWO DOOR GARAGE
direct sunlight (Fig. 4-4). – Red LED should always be on sunny side
whenever possible (Fig. 4-4). • For multiple doors. – Preventing crossed signals is critical. – Place source and sensor modules on adjacent
LED RED
RED
GREEN
GREEN
RED
LED
LED
LED
LED
doors facing in opposite directions (Fig. 4-4). NOTE: To help prevent interference from sun, Safety Beam sensor with Green LED may be placed further away from the door opening where it will spend more time in shadow.
FIG. 4-4 Safety Beam source and sensor
locations.
or 6 5 4 3 2 1 6 5 4 3 2 1
Dashed Line = striped wire
Solid Line = white wire
FIG. 4-5a Source and sensor wiring methods.

(1 ft) from sensor. - Split and strip ends of sensor wires and
or 6 5 4 3 2 1 6 5 4 3 2 1
pre-wired wires. (Fig. 4-7) - Splice wires together with (provided)
Dashed Line = striped wire
Solid Line = white wire
FIG. 4-5b Pre-Wired source and sensor wiring
methods.
Insert Wire Into Connector
Use this wire routing if NOT pre-wired
Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safety Beam System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.
Invisible Light Beam Protection Area
FIG. 4-6 Wire routing.
FIG. 4-7 Splitting and stripping.

in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably reach in and lightly press down locking clips.) Insert white wires to 'even' terminal holes and striped wires into 'odd' terminal holes (Fig. 4-8).
1 2 3 4 5 6 FIG. 4-8 Insert wires.
(Power Head With Rear Cover Not Shown)
1 2 3 4

– Confirm wire lock by lightly tugging on the wire.
FIG. 4-9 Install rear cover.




FIG. 5-1 Connect to power.


FIG. 5-2 Remove motor cover.
FIG. 5-3 Power cord strain relief.
Plug the operator into a properly grounded electrical outlet. (Fig. 5-1)
5" from floor
FIG. 5-4 Check Safety Beam Alignment.
1. When the garage door is opening, its movement will not be influenced if the safety beam is obstructed. 2. If the safety beam is obstructed before the garage door closes, the door will not close. 3. When the garage door is closing, if safety beam is cut off by people or obstacle, the garage door will reverse automatically to its fully opened position. (Meanwhile, the opener light will keep blinking until door moves to its fully opened position.) 4. If the Safety Beam System fails, loses power, or is installed improperly, you will have to press and hold the wall control "close" button until the door reaches its fully closed position. The LED indicator light on the power head will be green and blink twice (Pattern: ☼☼ pause ☼☼ pause) to inform you to eliminate problem first. Otherwise, the door will reverse automatically to its fully opened position if you release the "close" button on the wall control during the closing movement.
Motor Cover Screws





Limit Controls location on power head.
SETTING & TESTING OPEN/CLOSE LIMITS
The OPEN (UP) and CLOSE (DOWN) door positions are controlled by making the adjustments on the panel located on the bottom of the power head. The adjustments that can be made are:
LEARN LIMIT MANUAL
FORCE
Close Travel Limit, Open Travel Limit,
Maximum Closing Force, Maximum Opening Force, and Transmitter Programming. ENGAGE CHAIN TO CARRIAGE 1. Press and hold the "Close Travel Limit" button until the chain advances and engages carriage (Fig. 6-2).
CLOSE CODE
FIG. 6-1 Limit controls.
CLOSE TRAVEL LIMIT 1. Press and hold the "Close Travel Limit" button until the door is fully closed. 2. You can quickly press and release the "Close Travel Limit" button to move the door in small increments. You can also use the "Open Travel Limit" button to move the door slightly in the UP direction. 3. Door is fully closed when the bottom edge of door presses firmly onto the ground. 4. Once the door is in the desired position, press and release the "Down SET Limit" button. The LED indicator light light will blink green once. This stores the closed position in memory.


Chain - Master Link (engages to carriage)
FIG. 6-2 Engage Chain to Carriage.
OPEN TRAVEL LIMIT 1. Press and hold the "Open Travel Limit" button to move the door to its fully opened position. This starts the opener moving in the UP direction. 2. Hold the "Open Travel Limit" button until the door is in the fully opened position that you desire, then release this button. 3. You can quickly press and release the "Open Travel Limit" button to move the door in small increments. You can also use the "Close Travel Limit" button to move the door slightly in the DOWN direction. 4. Once the door is in the desired position, press and release the "Open SET Limit" button. The LED indicator light will blink green twice. This stores the opened position in memory.

DOOR
The Carriage Lock can be manually engaged or disengaged.
1. By turning the Down Force Control clockwise, the DOWN force can be increased. By turning the Down Force Control counter-clockwise, the DOWN force can be decreased. Set the DOWN force level at the minimum force required to close door without reversing. 2. Once the desired level is selected, this stores the maximum force level for the DOWN direction in memory. 3. By turning the Up Force Control clockwise, the UP force can be increased. By turning the Up Force Control counter-clockwise, the UP force can be decreased. Set the UP force level at the minimum force required to open door without stopping. 4. Once the desired level is selected, this stores the maximum force level for the UP direction in memory.
UNLOCK
LOCK
CLOSE
TO RELEASE PULL TOWARD THE OPENER
TO RECONNECT PULL TOWARD DOOR
FIG. 6-3 Engage/Disengage Carriage Lock.
OPEN
OPEN
FORCE
ROTATE CLOCKWISE
ERASE - OPEN/CLOSE TRAVEL LIMIT
ROTATE COUNTER-CLOCKWISE
FIG. 6-4 Force Control Adjustment.
CONTACT REVERSE TEST The force adjustments and limit switch settings MUST BE COMPLETED before testing. 1. Testing. • Open garage door using wall control. – Place a 2" x 4" board (laid flat) under center

programmed. It should not have reached its "close" limit before hitting board. – If the door STOPS but does not reverse,
decrease "CLOSE FORCE" control setting slightly (turn it counter-clockwise). • Test again. Repeat as necessary.
FIG. 6-5 2 x 4 under center of door opening.




A moving door can cause serious injury or death.
programmed. 1b. Multi Button Remote Programming. NOTE: Each button on a multi-button remote is designed for use with 1 door. You cannot program 2 buttons to operate the same door, nor can you program 1 button to operate 2 doors. You can program a maximum of 7 different transmitters or wireless devices. NOTE: Pushing two buttons simultaneously will erase programmed memory and limits must be reset.

Limit controls location on power head.
SET
FORCE
SET
CLOSE CODE
FIG. 7-1 Learn code button and LED





FIG. 8-1 Open battery cover.

– and + polarity marks
FIG. 8-2 Match battery polarity.

FIG. 8-3 Attach visor clip.



FIG. 9-1 Slide lens onto motor cover.

FIG. 9-2 Fasten lens.
Slide out · Light bulb · Lens tabs



If you have any questions, please do not hesitate to contact customer service at:
1.800.354.3643


(See section "CONTACT REVERSE.") – Operator still fails
CONTACT THE GENIE COMPANY OR AN AUTHORIZED GENIE DEALER. 3. Safety Beam System. • Red LED blinks. – check alignment (See section ).
SERVICE TECHNICIAN.
slightly. – If door moves quickly, HAVE DOOR SERVICED
Use wall control supplied with operator. Any other wall control can cause the operator to operate unexpectedly.


Operator circuit wiring diagram. This wiring diagram is for reference only.
Opening Cover May Cause Electric Shock. Remove power from operator prior to removing cover.
SURGE PROTECTOR (MOV) LIMITEUR DE SURTENSION PROTECTOR DE SOBRETENSIONES
1 2 3 4 1 2 3 1 2


PROBLEM WHAT TO DO
Operator does NOT run from wall control.
Door operator starts for no reason.
Door starts down, then STOPS before it’s closed.
Door starts down, then STOPS and goes back up.
Door will only run closed.
Door will only run open. • Check "CLOSE FORCE" adjustment (See section ). 6
Door starts up, but STOPS before it’s completely open.
Operator runs, but door does NOT move.
Remote control has less than 25 feet operating range or no operation.
Operator works from wall control, but NOT from remote control.
Safety Beam System malfunction.


Possible Problem Solution Red LED
showing OFF OFF Normal operation None required
1 BLINK, Pause (Repeat)
1 BLINK, Pause (Repeat)
2 BLINKS, Pause (Repeat)
3 BLINKS, Pause (Repeat)
4 BLINKS, Pause (Repeat)
1-800-35-GENIE • Reverse wire placement in power head connector. (See section ) 3
5 BLINKS, Pause (Repeat)
for service.
Power head LED · Green LED · showing

The Genie Company Professional Access Systems
What is covered: Any defect in material and product workmanship from personal, normal household use in accordance with the Owner’s Manual.
How to get warranty service: To obtain warranty service for your Genie product, you must provide proof of the date and place of purchase of the product.
For how long: Limited 1 year warranty on parts, 5 years on motor.
Who gets the warranty: This warranty is limited to the consumer who originally purchased the product.
Geographic scope: This warranty applies only to Genie products purchased and installed in the United States and Canada.
What we will do: If your Genie product is defective, we will send replacement parts or, at our option, repair or replace it at no charge to you. If we send replacement parts or repair your Genie product, we may use new or reconditioned replacement parts. If we choose to replace your Genie product, we may replace it with a new or reconditioned one of the same or similar design.
2. Service From Authorized Dealers. You also may obtain warranty service from Genie authorized dealers. We recom mend that you verify the dealer’s status by calling the Genie Consumer Connection at 1.800.654.3643 or by visiting www.geniecompany.com before scheduling warranty service. If warranty service is provided by an authorized dealer, Genie will provide all required parts under warranty at no charge to you, but the dealers are independent businesses and may charge for their services. Genie will not reimburse you or otherwise be responsible for those charges.
We suggest that you retain your original packing material in the event we choose to repair or replace your Genie product and request that you ship it to us. Be sure to include your name, address, telephone number, proof of date and place of purchase and a description of the operating problem. After repairing or replacing your Genie product, we will ship it to your home at no cost to you for parts and labor, but you will have to pay a minimum of $8.00 for shipping and handling charges.
Your choice of either one of the above-described service options is your exclusive remedy under this warranty.
What this warranty does not cover: This warranty does not cover batteries (which are considered replaceable parts), installation, commercial use, defects resulting from accidents, damage while in transit to our service location or damage resulting from alterations, misuse or abuse, lack of proper maintenance, unauthorized repair or modification of the product, affixing of any attachment not provided with the product, programming of the Remote Control Devices, Safety Beam adjustment/cleaning, staples through wiring, pinched or broken wires, Carriage disengaged, Force Control adjustments, door out of balance, broken springs or cables, power outages, use of extension cords, missing or damaged parts on discounted, clearanced, final sale or taped cartons, phantom operation, fire, flood, or acts of God, or other failure to follow the Owner’s Manual. FOR ANSWERS: CALL 1.800.354.3643
Limitations: IMPLIED WARRANTIES, INCLUDING THOSE OF FITNESS FOR A PARTICULAR PURPOSEAND MERCHANTABILITY (AN UNWRITTEN WARRANTY THAT THE PRODUCT IS FIT FOR ORDINARY USE), ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. GENIE WILL NOT PAY FOR: LOSS OF TIME; INCONVENIENCE; LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY DAMAGE CAUSED BY YOUR GENIE PRODUCT OR ITS FAILURE TO WORK; ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT.
Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
This warranty is the only one we will give on your Genie product, and it sets forth all our responsibilities regarding your Genie product. There are no other express warranties.
State and province rights: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and province to province.
Manufactured under one or more of the following U.S. patents: 3,898,582 4,041,259 4,048,630 4,064,487 4,103,238 5,222,403 Other Patents applied for.
CORRESPONDENCE WITH FACTORY MUST INCLUDE DATE / MFG . NO.
FILL THIS IN AT TIME OF INSTALLATION FOR YOUR OWN RECORDS, SO THAT IT WILL
BE AVAILABLE IF YOU EVER NEED TO CALL US.
Date Purchased / / Serial Number / / Operator Model Remote Control Model Store Purchased Store Address
or Dealer Name Dealer Address City State Zip
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM | p.18 | ||
| FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM | p.18 | ||
| INFRARED PROTECTION FUNCTION | p.18 | ||
| 1. When the garage door is opening, its movement will not be influenced if the safety beam is obstructed. 2. If the safety beam is obstructed before the garage door closes, the door will not close. 3. When the garage door is closing, if safety beam is cut off by people or obstacle, the garage door will reverse automatically to its fully opened position. (Meanwhile, the opener light will keep blinking until door moves to its fully opened position.) 4. If the Safety Beam System fails, loses power, or is installed improperly, you will have to press and hold the wall control "close" button until the door reaches its fully closed position. The LED indicator light on the power head will be green and blink twice (Pattern: ☼☼ pause ☼☼ pause) to inform you to eliminate problem first. Otherwise, the door will reverse automatically to its fully opened position if you release the "close" button on the wall control during the closing movement. | p.18 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.