Packaged Cooling with Electric Heat Rooftop Units Precedent ™ TSC060-120 50 Hz R T -PRC0 16-EN F ebr uary 20 04.
© 2004 American Standard Inc. All rights reserved RT -PRC0 16-EN Introduction Pr ecedent ™ . . . The same T rane quality ... with added flexibility .
3 RT -PRC0 16-EN Introduction Features and Benefits Application Considerations Selection Procedure Model Number Description General Data P erfor mance Data Zone Controls Electrical Data Jobsite Connec.
4 RT -PRC0 16-EN Features and Benefits Unit Cabinet The compact cabinet with rounded corners takes up less room and is less costly to ship. The beveled and ribbed top is not only aesthetically pleasing, it is designed to prevent water from pooling. Single Point Power A single electrical connection powers the unit.
5 RT -PRC0 16-EN Features and Benefits Flexible Applications • Only two roof curbs for the 5-10 ton Precedent line. . .simplifies curb selection. • ReliaT el microprocessor controls to meet either the simple or the more complex application. • Airflow is outstanding.
6 RT -PRC0 16-EN Features and Benefits Micro Controls Several years ago, T rane was the first to introduce microprocessor controls into the Light Commercial Market. That design, along with immeasurable experience, has provided the tec hnology for T rane’ s second- generation ReliaT el ™ microprocessor controls.
7 RT -PRC0 16-EN Features and Benefits F actory -installed Options Hinged A ccess Doors These doors permit easy access to the filter , fan/heat, and compressor/control sections. They reduce the potential roof damage from screws or sharp access door corners.
8 RT -PRC0 16-EN Features and Benefits Va r i T r a c When T rane’ s c hangeover V A V S ystem for light commercial applications is coupled with Precedent, it provides the latest in technological advances for comfort management systems and can allow thermostat control in every zone served by V ariT rac.
9 RT -PRC016-EN Application of this product should be within the cataloged airflow and cooling considerations. Low Ambient Cooling The Precedent ™ line features, with ReliaT el ™ microprocessor controls, low ambient cooling down to 18°C (0°F). Contact your local T rane Representative for more assistance with low ambient cooling applications.
10 RT -PRC016-EN Cooling Capacity Step 1 Calculate the building’ s total and sensible cooling loads at design conditions. Use the T rane calculation methods or any other standard accepted method. Factors used in unit selection: A T otal Cooling Load: 16.
11 RT -PRC016-EN Selection Procedure - IP Units Cooling Capacity Step 1 Calculate the building’ s total and sensible cooling loads at design conditions.
12 RT -PRC016-EN Model Number Description Digit 1 - Unit Function T = DX Cooling Digit 2 - Efficiency S = Standard Efficiency Digit 3 - Airflow C = Convertible Digits 4,5,6 - Nominal Gross Cooling Capacity (MBh) kW T ons 060 = 17.6 5 072 = 21.1 6 090 = 26.
13 RT -PRC016-EN General Data T able GD - 1 — General Data Convertible Units Convertible Units Convertible Units Convertible Units Convertible Units TSC060AD TSC072AD TSC090AD TSC102AD TSC120AD Cooling Performance 1 Gross Capacity - kW (MBh) 18.2 (62.
14 RT -PRC016-EN Performance Data T able PD-1 — Gross Cooling Capacities (kW) - TSC060AD - (SI) Enter . 30 35 40 45 Dry Bulb m 3 /h T emp 16 19 22 16 19 22 16 19 22 16 19 22 Airflow (C) TGC SHC TGC SHC TG C SHC TGC SHC TGC SHC TGC S HC TGC SHC TGC SHC TG C SHC TGC SHC TGC SHC TG C SHC 24 16.
15 RT -PRC016-EN Performance Data T able PD-2 — Gross Cooling Capacities (kW) - TSC072AD - (SI) Enter . 30 35 40 45 Dry Bulb m 3 /h T emp 16 19 22 16 19 22 16 19 22 16 19 22 Airflow (C) TGC SHC TGC SHC TG C SHC TG C SHC TG C SHC TGC SHC TGC SHC T GC SHC TGC SHC TGC SH C TGC SH C TGC S HC 24 20.
16 RT -PRC016-EN Performance Data T able PD-3 — Gross Cooling Capacities (kW) - TSC090AD - (SI) Enter . 30 35 40 45 Dry Bulb m 3 /h T emp 16 19 22 16 19 22 16 19 22 16 19 22 Airflow (C) TGC SHC TGC SHC TG C SHC TG C SHC TGC S HC TGC SHC TGC SHC T GC SHC T GC SHC T GC SHC T GC SHC TGC SHC 24 24.
17 RT -PRC016-EN Performance Data T able PD-4a — Gross Cooling Capacities (MBH) - TSC1 02AD - (IP) Enter . 85 95 105 115 Dry Bulb CFM T emp 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (F) T GC SHC TGC SHC TG C SHC T GC SH C TGC S HC TGC SHC TGC SH C TGC SHC TGC SHC TG C SHC T GC SHC TGC SHC 75 96.
18 RT -PRC016-EN Performance Data T able PD-5 — Gross Cooling Capacities (kW) - TSC120AD - (SI) Enter . 30 35 40 45 Dry Bulb m 3 /h T emp 16 19 22 16 19 22 16 19 22 16 19 22 Airflow (C) TGC SHC TGC SHC TG C SHC TG C SHC TGC S HC TGC SHC TGC SHC T GC SHC T GC SHC T GC SHC T GC SHC TGC SHC 24 31.
19 RT -PRC016-EN T able PD-6 — Belt Driv e Evapor ator F an P erfor mance - TSC060AD - Downflow Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
20 RT -PRC016-EN Performance Data External Static Pressure (Inc hes of W ater) 1.10 1.20 1.30 1.40 1.50 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1/2 HP Standard Motor & Drive 1-1/2 HP Standard Motor & Hi Static Drive 1600 1206 1.12 1241 1.20 1275 1.
21 RT -PRC016-EN Performance Data T able PD-8 — Belt Driv e Evapor ator F an P erfor mance -TSC072AD - Downflow Configur ation (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
22 RT -PRC016-EN Performance Data T able PD-9a — Belt Drive Ev aporator F an Perf or mance -TSC072AD - Horiz ontal Configuration (IP) External Static Pressure (Inc hes of W ater) .
23 RT -PRC016-EN Performance Data T able PD-1 0 — Belt Drive Ev aporat or F an Perf or mance -TSC090AD - Downflow Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
24 RT -PRC016-EN Performance Data T able PD-1 1 — Belt Drive Ev aporator F an Perf or mance -TSC090AD - Horiz ontal Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
25 RT -PRC016-EN Performance Data T able PD-12 — Belt Drive Ev aporat or Fan P erformance -TSC1 02AD - Downflow Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
26 RT -PRC016-EN Performance Data T able PD-13 — Belt Drive Ev aporator F an Perf or mance -TSC1 02AD - Horiz ontal Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 1.
27 RT -PRC016-EN Performance Data External Static Pressure (Pascals) 275 300 325 350 375 400 425 450 475 500 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.24 Nom kW Standard Motor & Drive 5440 917 1.36 945 1.47 973 1.
28 RT -PRC016-EN Performance Data T able PD-15 — Belt Drive Ev aporat or Fan P erfor mance -TSC120AD - Horiz ontal Configuration (SI) External Static Pressure (Pascals) 25 50 75 100 125 150 175 200 225 250 m 3 /h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.
29 RT -PRC016-EN Performance Data T able PD-16 — Standard Motor & Sheav e/F an Speed (RPM) Unit 6 T urns 5 T urns 4 T urns 3 T urns 2 T urns 1 T urns Model No.
30 RT -PRC016-EN Performance Data T able PD-21 — Static Pressur e Drops Through Accessor ies - (P ascals) Economizer Electric Heater OA/RA Dampers 2 Accessory (kW) 3 Unit Airflow Standard Pleated Filters 100% OA 100% RA 100% OA 100% RA Model No.
31 RT -PRC016-EN Performance Data T able PD-23 — A uxiliary Electric Heat Capacity (SI) T otal 2 Stage 1 Stage 2 Unit Unit Model No. V oltage KW No. Stages K W KW 7.5 / 9.0 2 3.75 / 4.5 3.75 / 4.5 TSC060AD 380-415/50 /3 10.9 / 13.0 2 5.45 / 6.5 5.45 / 6.
32 RT -PRC016-EN Performance Data T able PD-24 — Air T emperature Rise Across Electr ic Heaters (Degr ees C) kW 3400 m 3 /h 4100 m 3 / h 5100 m 3 /h 5800 m 3 /h 6800 m 3 /h 380V / 415V V oltage Stages TSC060AD TSC072AD TSC090AD TSC102AD TSC120AD 07.
33 RT -PRC016-EN Conventional Thermostats Conventional Thermostats are the building occupant’ s comfort control devises when a generic thermostat is desired. Manual Changeover — One Heat, One Cool Thermostat. Heat, Cool or Off System Switch. Fan Auto or On Switch.
34 RT -PRC016-EN T able ED-3 — Electrical Char acter istics - Evapor ator F an Motor - 50 Hz Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Unit Amps Amps Model No. No. V olts Phase HP FLA LRA No. V olts Phase HP FLA LRA TSC060AD 1 380-415 3 1.
35 RT -PRC016-EN For specific wiring information, see the installation instructions. All wiring except power wires is low voltage. All customer supplied wiring to be copper and must conform to NEC or CEC and local electrical codes. Wiring shown dotted is to be furnished and installed by the customer.
36 RT -PRC016-EN Dimensional Data All dimensions are in inches/millimeters. TSC060 TSC060.
37 RT -PRC016-EN Dimensional Data TSC060 All dimensions are in inches/millimeters. TSC060 — Hori zontal Airflow Supply/Retur n TSC060 — Downflow Airflow Supply/Retur n TSC060 — Unit Clearance an.
38 RT -PRC016-EN Dimensional Data TSC060 All dimensions are in inches/millimeters. TSC060 — Downflow Duct Connections — Field Fabricated TSC060 — Roof Curb.
39 RT -PRC016-EN Dimensional Data TSC072-120 All dimensions are in inches/millimeters. TSC072-090 TSC102-120.
40 RT -PRC016-EN Dimensional Data TSC072-120 All dimensions are in inches/millimeters. TSC072-120 — Downflow Airflow Supply and Return TSC072-120 — Hor izontal Airflow Supply and Return TSC072-120.
41 RT -PRC016-EN Dimensional Data TSC072-1 20 All dimensions are in inches/millimeters. ALL FLANGES 1 1/4” (31 MM) TSC072-120 — Downflow Duct Connections — Field Fabricated TSC072-120 — Roof C.
42 RT -PRC016-EN Dimensional Data TSC060 Options/Accessories All dimensions are in inches/millimeters. TSC060 — Economizer , Manual or Motorized Fresh Air Damper TSC060 — Barometric Relief Damper .
43 RT -PRC016-EN Dimensional Data TSC072-120 Options/Accessories All dimensions are in inches/millimeters. TSC072-120 — Economizer and Barometric Relief Damper Hoods TSC072-120 — Swing Diameter fo.
44 RT -PRC016-EN W eights T able W -1 - Maximum Unit and Cor ner W eights and Center of Gravity Dimensions (SI) Maximum W eights (2) (kg) Corner W eights (1) (kg) Center of Gravity (mm) Unit Model No.
45 RT -PRC016-EN Mechanical Specifications General The units shall be conver tible airflow. The operating range shall be between 46°C and -18°C (1 15°F and 0°F) in cooling as standard from the factory for all units.
46 RT -PRC016-EN A ccessor ies/Options Electric Heaters Field-installed electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy-duty nic k el c hromium elements internally delta connected for 200 volt, wye connected for 380-415 volt.
47 RT -PRC016-EN Mechanical Specifications Control Options Comm-3/4 T rane Communication Interface This factory or field-installed option shall be provided to interface microprocessor controlled units with the T rane Integrated Comfort ™ systems.
Literature Order Number File Number Supersedes Stocking Location T rane has a policy of continuous product and product data improvement and reserves the right to c hange design and specifications without notice T rane A business of American Standard Companies www .
An important point after buying a device Trane TSC060-120 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Trane TSC060-120 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Trane TSC060-120 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Trane TSC060-120 you will learn all the available features of the product, as well as information on its operation. The information that you get Trane TSC060-120 will certainly help you make a decision on the purchase.
If you already are a holder of Trane TSC060-120, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Trane TSC060-120.
However, one of the most important roles played by the user manual is to help in solving problems with Trane TSC060-120. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Trane TSC060-120 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center