6104 BCF5 R07 1 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner : Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 6104 BCF5 R07 T able of Contents General Information .............................................. 2-4 Hazard De fi nitions .......................................................... 3 Agency approvals .............................................
6104 BCF5 R07 3 Hazar d de fi nitions Intended to bring special attention to information, but not related to personal injury or property damage. NO TICE Indicates a potentially hazardous situation, which, if not avoided, may result in person- al injury or property damage.
4 6104 BCF5 R07 Combustion air supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or combustion air openings comply with National Fire Protection Standard for Oil-Burning Equipment, NFP A 31.
6104 BCF5 R07 5 Fuel supply The fuel supply piping and tank must provide #1 or #2 fuel oil at pressure or vacuum conditions suitable for the fuel unit (oil pump) on the burner . Refer to fuel unit literature in the literature envelope in the burner carton to verify allowable suction pressure.
6 6104 BCF5 R07 V erify bur ner components — Burner , Model CF500 or CF800 Air tube assembly Mounting fl ange kit Oil nozzle , per T able 1 — Only 45° to 70° solid pattern nozzles are recommended unless otherwise speci fi ed by appliance manufacturer .
6104 BCF5 R07 7 Mount the bur ner Mount fl ange(s) on air tube This section does not apply to burners with welded fl ang- es. Do not install air tube on burner . For non-pr essur e fi ring fl ange , refer to Figure 4 : Install gasket (item a ) and fl ange (item d ).
8 6104 BCF5 R07 50001 End view Side view 3/16” - 7/32” gap 1/4” in front of nozzle 3/16” above nozzle center R P Q Install nozzle line assembl y Insert the nozzle line assembly into the burner air tube.
6104 BCF5 R07 9 125-200 psig 125-200 psig 3502 The burner is shipped without the by-pass plug in- stalled. Intall the by-pass plug in two-pipe oil supply systems ONL Y . y y Failure to comply could cause immediate pump seal failure, pressurized oil leakage and the po- tential for a fi re and injury hazard.
10 6104 BCF5 R07 W ir e the bur ner — R7184 Disconnect electrical power before installing or servic- ing the burner . Provide ground wiring to the burner , metal control en- closures and accessories.
6104 BCF5 R07 11 Keep Service Access Covers Securely Installed These covers must be securely in place to prevent electrical shock, damage from exter- nal elements, and protect against injury from moving parts. All covers or service access plates must be in place at all times except during maintenance and service.
12 6104 BCF5 R07 Star t the Bur ner Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is very hot. Do not attempt to re-establish fl ame with the burner running if the fl ame becomes extinguished during start- up, venting, or adjustment.
6104 BCF5 R07 13 the control will lock out. Press the reset button to reset the control and return to the functions listed in the previous step. Repeat the previous steps if needed, until the pump is fully primed and the oil is free of bubbles. Then terminate the call for heat, and the control will resume normal operation.
14 6104 BCF5 R07 Maintenance and Ser vice Do not tamper with the burner or controls or make any adjustments unless you are a trained and quali fi ed service technician. T o ensure continued reliable operation, a quali fi ed service technician must service this burner annually .
6104 BCF5 R07 15 R eplacement par ts 1 2 3 10 9 8 4 5 6 7 11 12 13 15 14 16 Item Part Name/Description Part Number 1 Air T ube Specify 2 Spline Nut 3666 3 Adjusting plate assembly 51286U 4 Blocking Oi.
16 6104 BCF5 R07 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for .
An important point after buying a device Beckett CF500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Beckett CF500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Beckett CF500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Beckett CF500 you will learn all the available features of the product, as well as information on its operation. The information that you get Beckett CF500 will certainly help you make a decision on the purchase.
If you already are a holder of Beckett CF500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Beckett CF500.
However, one of the most important roles played by the user manual is to help in solving problems with Beckett CF500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Beckett CF500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center