Instruction/ maintenance manual of the product AFII 100 Beckett
Go to page of 16
RWB 6104 BAFII R01 Page 1 Model AFII Oil Burner Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsi- bilities in caring for your heating equipment.
Page 2 RWB 6104 BAFII R01.
RWB 6104 BAFII R01 Page 3 T able of Contents General Information Hazard De fi nitions ...................................................................................................................... .................. 4 Owner ’s Responsibility .
Page 4 RWB 6104 BAFII R01 General Infor ma tion General Information Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.
RWB 6104 BAFII R01 Page 5 General Speci fi cation T able 1 – Burner Speci fi cations Capacity ‘HLX’ Heads Firing rate: - 0.40 – 1.50 GPH Input: Min./Max - 56,000 /210,000 Btu/h ‘FBX’ Heads Firing rate: - 0.40 – 1.35 GPH Input: Min./Max.
Page 6 RWB 6104 BAFII R01 Inspect/Prepar e Installation Site Inspect Chimney or Direct V ent System Inspect the chimney or vent. Make sure it is properly sized and in good working condition. Follow the in- structions supplied by the appliance manufacturer .
RWB 6104 BAFII R01 Page 7 Never use T e fl on tape on fuel oil fi ttings. T ape fragments can lodge in fuel line components and fuel unit, damaging the equipment and pre- venting proper operation. Use oil-resistant pipe sealant compounds. • • • Damage to the pump could cause impaired burn- er operation, oil leakage and appliance soot-up.
Page 8 RWB 6104 BAFII R01 The burner is supplied with either a one-stage pump or a two-stage pump based on the oil supply system requirements. Consult the instructions pro- vided with the pump for installation speci fi cations.
RWB 6104 BAFII R01 Page 9 Star t the Bur ner and Set Combustion Figure 4. – T ypical Wiring, R7184 Primary Control SK9359 7. RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner , enters a 60 second recycle delay , and then repeats the above ignition sequence.
Page 10 RWB 6104 BAFII R01 If the burner locks out on safety during bleed- ing, reset the safety switch and complete the bleeding procedure. Note — Electronic safety switches can be reset immediately; others may require a three- to fi ve-minute wait.
RWB 6104 BAFII R01 Page 1 1 If motor is not permanently lubricated, oil motor with a few drops of SAE 20 nondetergent oil at each oil hole. DO NOT over oil motor . Exces- sive oiling can cause motor failure. Check motor current. The amp draw should not exceed the nameplate rating by more than 10%.
Page 12 RWB 6104 BAFII R01 Inspect the nozzle adapter before installing the new nozzle. If it is grooved or scratched on the sealing surface, replace the nozzle line assem- bly . If the surface is damaged, oil could leak at the nozzle to adapter joint, causing serious com- bustion problems.
RWB 6104 BAFII R01 Page 13 Stop Screw AFII 85 AFII 100 AFII 150 0 0.40-0.65 0.5-0.65 0.75-1.00 1 - 0.6-0.75 0.85-1.10 2 - 0.65-0.80 0.95-1.15 3 0.60-0.75 0.65-0.90 0.95-1.20 4 - 0.75-0.95 1.10-1.25 5 0.70-0.85 0.85-1.00 1.15-1.35 6 - 0.95-1.10 1.15-1.
Page 14 RWB 6104 BAFII R01 For best performance specify genuine Beckett replacement parts R eplacement Par ts Diag r am Beckett 10 8 21 11 16 17 6 18 14 7 4 20 22 9 5 15 2 13 23 3 19 12 1 SK8265B.
RWB 6104 BAFII R01 Page 15 Item Description Kit No. 1 Air tube combination Specify 2 Blower Wheel: AFII 85 (4-1/4”) AFII 100 (4-1/2”) AFII 150 (4-1/2”) 21439U 21438U 21438U 3 Electrical box 3061.
Page 16 RWB 6104 BAFII R01 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Be.
An important point after buying a device Beckett AFII 100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Beckett AFII 100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Beckett AFII 100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Beckett AFII 100 you will learn all the available features of the product, as well as information on its operation. The information that you get Beckett AFII 100 will certainly help you make a decision on the purchase.
If you already are a holder of Beckett AFII 100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Beckett AFII 100.
However, one of the most important roles played by the user manual is to help in solving problems with Beckett AFII 100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Beckett AFII 100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center