Vacuum cleaner Auris 2000 Auris 2200 Auris ionic 2200

Safety advice and warnings

- Read these instructions carefully before switching on the appliance and keep them for future reference. Failure to follow and observe these instructions may result in an acci- dent. Failure to follow and observe these instructions may result in an accident.

Many thanks for choosing to purchase a TAURUS brand product. Thanks to its technology, design and operation and the fact that it exceeds the strictest quality standards, a fully satisfactory use and long product life can be assured.

Electric safety: - Do not use the appliance if the cable or plug is damaged. - Ensure that the voltage indicated on the nameplate matches the mains voltage before plugging in the appliance. - Connect the appliance to a base with an earth socket withstanding a minimum of 10 amperes. - The appliance’s plug must fit into the mains socket properly. Do not alter the plug. Do not use plug adaptors. - Do not leave the appliance out in the rain or exposed to moisture. If water gets into the appliance, this will increase the risk of electric shock. - If any of the appliance casings breaks, immediately disconnect the appliance from the mains to prevent the possibility of an electric shock. - Do not force the electrical wire. Never use the electric wire to lift up, carry or unplug the appliance. - Check the state of the power cord. Damaged or tangled cables increase the risk of electric shock. - Do not touch the plug with wet hands.

Description A Vacuum cleaner base B Extendable extension tube C Hose set D Manual air regulator E Hose head F Automatic cord rewind G Electronic power control H On/off switch I Bag full indicator J Switch to open bag compartment K Transportation handle L Bag compartment cover M Wheels N Plug housing O Vacuum cleaner base for delicate floors: P Lance + Multi-use brush Q Outlet filter cover R Outlet filter S Motor filter T Bag

Dear customer,

Page 2 of the Taurus Group 2200 user manual — English
Page 2 · click to enlarge
Page 2

Use and care:

- Do not use the appliance if the accessories or parts are not fastened together properly. - Do not use the appliance if the ac- cessories attached to it are defective. Replace them immediately. - Do not use the appliance to vacuum up water or any other type of liquid. - Do not use the appliance if the on/ off switch does not work. - Do not force the appliance’s work capacity. - Disconnect the appliance from the mains when not in use, before cleaning, making any adjustment, battery charge or accessory change. - This appliance is for household use only, not professional or industrial use. - This appliance is not a toy. Children should be supervised to ensure that they do not play with the appliance. - This appliance is intended for adult use. Ensure that this product is not used by the disabled, children or people unused to its handling. - This appliance should be stored out of reach of children and/or the disabled. - Make sure that dust, dirt or other foreign objects do not block the fan grill on the appliance. - Check that the lid is closed properly before starting the appliance. - Any misuse or failure to follow the instructions for use renders the guarantee and the manufacturer’s liability null and void.

Vacuuming function: - Fit the hose unit to the vacuum cleaner’s air intake. - To disconnect the hose unit from the vacuum cleaner, press the two buttons on the hose joint at the same time and pull outwards (Fig. 1).

Insertion of accessories into the appliance’s grip: - The appliance’s grip is designed in such a way that it allows the insertion of the following accessories: (use the combination that best meets your requirements) - Extendable extension tube: Desig- ned to provide access to surfaces which are out of reach and make floor cleaning comfortable, its length can be adjusted by using the adjustment control. (Fig. 2). - Vacuum cleaner base: Specially designed for cleaning floors (both rugs, carpets and hard floors), its base has a retractable brush that can be adjusted to two heights for greater efficiency on these floors. It is advisable to have the brush out for hard floors and the brush in for rugs and carpets. - Vacuum cleaner base for delicate floors: specially designed for deli- cate floors, such as parquet wooden flooring. - Lance: specially designed for getting into cracks and difficult corners. - Upholstery brush: Especially suita- ble for cleaning textile surfaces.

Instructions for use

Page 3 of the Taurus Group 2200 user manual — English
Page 3 · click to enlarge
Page 3

Use:

position, fix the break pad hook to the hook situated on the rear side of the appliance.

- Take the length of cable required out of the housing. - Connect the appliance to the mains. - Turn the appliance on using the on/ off switch. - Select the desired speed.

Safety thermal protector: - The appliance has a safety device, which protects the appliance from overheating. - If the appliance turns itself off and does not switch itself on again, dis- connect it from the mains supply, and wait for approximately 15 minutes before reconnecting. If the machine does not start again seek authorised technical assistance.

Electronic power control: - The power of the appliance can be regulated by using the power regula- tor control. This function is very use- ful, as it makes it possible to adapt the power of the appliance to the type of work that needs to be done.

Once you hace finished using the appliance: - Turn the appliance off, using the on/ off switch. - Unplug the appliance to the mains. - Retract the cable by pressing the roller cable button and guide the cable into the appliance.

- Disconnect the appliance from the mains and let it cool before underta- king any cleaning task. - Clean the equipment with a damp cloth with a few drops of washing-up liquid and then dry. - Do not use solvents, or products with an acid or base pH such as blea- ch, or abrasive products, for cleaning the appliance. - Do not submerge the appliance in water or any other liquid, or place it under a running tap.

Carry handle/s: - The device has a handle on the upper part so it can be transported easily and comfortably.

Parking position: - This appliance has two parking positions for comfortable and straightforward storage. - To make use of the vertical parking put the appliance in a vertical position (so that the back part of the appliance is now leaning against the floor) secure the hook of the head to the hook which can be found on the lower part of the appliance. - To use the horizontal parking

Changing the dust bag: - Change the dust bag when there is a noticeable reduction in the suction power of the appliance. (The dust bag does not necessarily have to be full to need changing; for example, if very fine dust has been vacuumed this can cover the pores in the bag and make it necessary to replace it).

Cleaning

Page 4 of the Taurus Group 2200 user manual — English
Page 4 · click to enlarge
Page 4

- In any case, change the bag when the bag full indicator is completely red. - Disconnect the hose from the vacuum cleaner’s air intake. - Open bag compartment cover. (Fig. 3) - Remove the bag from the bag support. (Fig. 4) - Check the condition of the motor filter. - Replace the bag with another one, fitting it to the bag support. - Close the bag compartment cover; making sure it is shut properly. - Connect the hose to the vacuum cleaner’s air intake.

- To reassemble the filter, proceed with the above instructions, in reverse order.

Supplies - Supplies can be acquired from distributors and authorised establish- ments (such as filters, etc. ) for your appliance model. - Always use original supplies, desig- ned specifically for your appliance model.

- Take the appliance to an authorised technical support service if problems arise. Do not try to dismantle or repair without assistance, as this may be dangerous. - If the connection to the mains has been damaged, it must be replaced and you should proceed as you would in the case of damage.

Changing the filters: Motor filter: - it is advisable to be changed at least once a year or every 100 hours of the appliance’s use. - To remove filters: - Open bag compartment cover. - The filter motor can be found in the motor’s turbine air entrance. - Remove the filter from its housing. (Fig. 5) -To reassemble the filter, proceed with the above instructions, in reverse order.

For EU product versions and/or in case that it is requested in your country:

Ecology and recyclability of the product

- The materials of which the packa- ging of this appliance consists are included in a collection, classification and recycling system. Should you wish to dispose of them, use the appropriate public containers for each type of material. - The product does not contain concentrations of substances that could be considered harmful to the environment

HEPA air vent filter: - HEPA air vent filter (High efficiency air filter that efficiently retains spores, ash, sawdust, pollen…), it is advisable to change it a least once a year or after every 100 hours of use. - To remove filters: - Open the air outlet grate to access the filter (Fig 6). - Remove the filter from its housing.

Anomalies and repair

Page 5 of the Taurus Group 2200 user manual — English
Page 5 · click to enlarge
Page 5
Taurus Group 2200 — English diagram (page 5)
Fig. 1 · English

This symbol means that in case you wish to dispose of the product once its working life has ended, take it to an authorised waste agent for the selective collection of waste electrical and electronic equipment (WEEE)

NB: By virtue of the conditions of fa- brication of this product, the maximum absorbed power can differ from that specified.

This appliance complies with Direc- tive 2006/95/EC on Low Voltage and Directive 2004/108/EC on Electro- magnetic Compatibility.

Ask about the Taurus Group 2200

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Taurus Group 2200

Be the first to ask — other owners or our team will answer.

Original document

Taurus Group 2200 manual PDF

72 pages·1.1 MB·Vacuum Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…