EN
TANDBERG logo
Official user manual

TANDBERG Edge MXP

302 pages·3.2 MB·Projector·PDF·ENDEFRITNLJA
TANDBERG Edge MXP
Table of Contents 222 sections 1 Introduction · 1.1 At a Glance · 1.2 Menu Structure · 2 Installation · … ShowHide
1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 1 of the TANDBERG Edge MXP user manual — User Manual
Page 1 · click to enlarge
Page 1
TANDBERG Edge MXP diagram (page 1)
Fig. 1

User Manual

TANDBERG Edge MXP — User Manual diagram (page 1)
Fig. 2 · User Manual

D13358.06 March 2006

This document is not to be reproduced in whole or in part without permission in writing from:

Software version F4

Page 2 of the TANDBERG Edge MXP user manual — CMU-SNMP
Page 2 · click to enlarge
Page 2

Trademarks and Copyright

All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or otherwise, without the prior written permission of TANDBERG. Nationally and internationally recognized trademarks and trade names are the property of their respective holders and are hereby acknowledged.

Amended / Expanded Copyright notices for third-party software on the TANDBERG MXP systems are listed below:

Full copies of the licenses and warranty statements are located on the product CD in the license files directory.

The non-commercial third party code is distributed in binary form under the terms of non-copyleft style open source licenses such as BSD, Artistic or MIT/X Consortium.

The product also has some binary code distributed under the terms of the GNU public license with an exemption which allows static links to non-copyleft commercial code.

In accordance with section (3) of the GNU General Public License, copies of such code will be provided upon request by contacting TANDBERG. Please contact us by using the Online Support section at www.tandberg.net or the “contact us” section of this manual. Please provide USD 10.00 for media and shipping.

Contains iType™ from Monotype Imaging Corporation.

TANDBERG Edge MXP — Trademarks and Copyright diagram (page 2)
Fig. 3 · Trademarks and Copyright

CMU-SNMP

Copyright 1988, 1989, 1991, 1992 by Carnegie Mellon University All Rights Reserved

CMU-SNMP is distributed under the terms of the CMU SNMP license, which is an open source license similar to a BSD or X Consortium License.

Dropbear - an SSH2 server

Copyright (c) 2002,2003 Matt Johnston All rights reserved.

The Dropbear SSH2 server is distributed under the terms of the Dropbear License, which is a MIT/X Consortium style open source license.

Third Party Software · Agfa

Page 3 of the TANDBERG Edge MXP user manual — ICU
Page 3 · click to enlarge
Page 3

eCos, the Embedded Configurable Operating System.

Copyright (C) 1998, 1999, 2000, 2001, 2002, 2003 Red Hat, Inc.

Copyright (C) 2002, 2003 John Dallaway

Copyright (C) 2002, 2003 Nick Garnett

Copyright (C) 2002, 2003 Jonathan Larmour Copyright (C) 2002, 2003 Andrew Lunn Copyright (C) 2002, 2003 Gary Thomas Copyright (C) 2002, 2003 Bart Veer

Copyright (c) 1982, 1986, 1991, 1993 The Regents of the University of California. All rights reserved.

(c) UNIX System Laboratories, Inc.

All or some portions of this file are derived from material licensed to the University of California by American Telephone and Telegraph Co. or Unix System Laboratories, Inc. and are reproduced herein with the permission of UNIX System Laboratories, Inc.

Copyright (C) 1995, 1996, 1997, and 1998 WIDE Project. * All rights reserved.

Copyright (c) 2000 Brian Somers

Copyright (c) 1998 The NetBSD Foundation, Inc. * All rights reserved.

Copyright (c) 1997 Niklas Hallqvist. All rights reserved.

Copyright (c) 1988 Stephen Deering.

Copyright (c) 1992, 1993 The Regents of the University of California. All rights reserved.

This code is derived from software contributed to Berkeley by Stephen Deering of Stanford University.

Portions of eCos code are distributed under several BSD style licenses. Other portions of eCos code are distributed under the terms of the GNU General Public License with a non-copyleft exception which allows static links to non-copyleft programs.

ExPat XML Parser:

Copyright (c) 1998, 1999, 2000 Thai Open Source Software Center Ltd and Clark Cooper

Copyright (c) 2001, 2002, 2003, 2004, 2005, 2006 Expat maintainers.

The ExPat XML parser is distributed under the terms of the ExPat License which is a MIT/X Consortium style open source license

ICU

ICU License - ICU 1.8.1 Copyright (c) 1995-2003 International Business Machines Corporation and others All rights reserved.

ICU is distributed under the terms of the ICU license, which is a MIT/X Consortium style license.

Copyright (c) 1998-2004 The OpenSSL Project. All rights reserved.

This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/)"

Copyright (C) 1995-1998 Eric Young (eay@cryptsoft.com) * All rights reserved.

OpenSSL is distributed under the terms of the OpenSSL and SSLeay licenses, which are both BSD style open source licenses.

User Manual · eCos · OpenSSL

Page 4 of the TANDBERG Edge MXP user manual — COPYRIGHT © 2005–2006, TANDBERG
Page 4 · click to enlarge
Page 4

Copyright 1999, Mark Martinec. [email protected] All rights reserved

Snprintf is distributed under the terms of the snprintf license, which is a Frontier Artistic style open source license.

A standard copy of snprintf can be located at the author’s web site: http://www.ijs.si/software/snprintf/

xSupplicant (wpa_supplicant) 802.1x

Copyright (c) 2002-2005, Jouni Malinen [email protected]

xSupplicant is distributed under the terms of the xSupplicant license, which is a BSD style open source license.

Disclaimer The information in this document is furnished for informational purposes only, is subject to change without prior notice, and should not be construed as a commitment by TANDBERG. The information in this document is believed to be accurate and reliable; however TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document, nor for any infringements of patents or other rights of third parties resulting from its use. No license is granted under any patents or patent rights of TANDBERG. This document was written by the Research and Development Department of TANDBERG, Norway. We are committed to maintain a high level of quality in all our documentation. Towards this effort, we welcome you to Contact us with comments and suggestions regarding the content and structure of this document.

COPYRIGHT © 2005–2006, TANDBERG

snprintf

Page 5 of the TANDBERG Edge MXP user manual — Environmental Issues
Page 5 · click to enlarge
Page 5

Environmental Issues

TANDBERG visual communication products significantly reduce the need for travel and thereby help reduce various types of pollution. TANDBERG recommends the use of low energy peripherals, such as EnergyStar™ monitors. Thank you for buying a TANDBERG product. Battery handling The batteries for the Remote Control are Long Life Alkaline batteries, which means you will need fewer batteries, further benefiting the environment. Please follow the guidelines on the packing material for handling and disposal instructions for the batteries. Waste handling This TANDBERG product contains no consumables that require disposal. You should retain the packaging materials in case future shipment is necessary. Please contact your local authorities for information on waste handling and recycling regulations for electronic products Production of products Our factories employ the most efficient environmental methods for reducing waste and pollution. Our designers do their best to ensure TANDBERG products are highly recyclable. Digital User Manuals TANDBERG is pleased to announce that it has replaced the printed versions of its User Manuals with a digital CD version. Instead of a range of different user manuals, there is now one CD which can be used with all TANDBERG MXP products. The CD contains a variety of supported languages. The environmental benefits of digital manuals are significant, from saving paper, to reduced weight for shipping. Even the CD itself is recyclable. Not only are they more ecological, digital manuals are more user friendly. A simple web-based search feature helps users directly access the information they need. In addition, this TANDBERG video system now has an intuitive on-screen help function, which provides a range of useful features and tips. If desired, the user manuals on the CD can still be printed locally.

User Manual

Page 6 of the TANDBERG Edge MXP user manual — Operator Safety Summary
Page 6 · click to enlarge
Page 6

Operator Safety Summary

For your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions and instructions both on the apparatus and in the operating instructions.

Equipment Markings The lightning flash symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltages” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock. The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions accompanying the equipment.

TANDBERG Edge MXP — Operator Safety Summary diagram (page 6)
Fig. 4 · Operator Safety Summary

ƒ Water and moisture - Do not operate the equipment under or near water - for example near a bathtub, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool or in areas with high humidity. ƒ Cleaning - Unplug the apparatus from the wall outlet before cleaning or polishing. Do not use liquid cleaners or aerosol cleaners. Use a lint-free cloth lightly moistened with water for cleaning the exterior of the apparatus. ƒ Ventilation - Do not block any of the ventilation openings of the apparatus. Install in accordance with the installation instructions. Never cover the slots and openings with a cloth or other material. Never install the apparatus near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. ƒ Grounding or Polarization - Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician. ƒ Power-Cord Protection - Route the power cord so as to avoid it being walked on or pinched by items placed upon or against it, paying particular attention to the plugs, receptacles, and the point where the cord exits from the apparatus. ƒ Attachments - Only use attachments as recommended by the manufacturer. ƒ Accessories - Most systems should only be used with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. ƒ Lightning - Unplug this apparatus during lightning storms or when unused for long periods of time.

Page 7 of the TANDBERG Edge MXP user manual
Page 7 · click to enlarge
Page 7

ƒ ISDN cables - CAUTION - To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. ƒ Servicing - Do not attempt to service the apparatus yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel. ƒ Damaged Equipment - Unplug the apparatus from the outlet and refer servicing to qualified personnel under the following conditions:

ƒ When the power cord or plug is damaged or frayed ƒ If liquid has been spilled or objects have fallen into the apparatus ƒ If the apparatus has been exposed to rain or moisture ƒ If the apparatus has been subjected to excessive shock by being dropped, or the cabinet has been damaged ƒ If the apparatus fails to operate in accordance with the operating instructions

User Manual

Page 8 of the TANDBERG Edge MXP user manual — Contact us
Page 8 · click to enlarge
Page 8

Contact us

If you have any questions, comments or suggestions, please see the Online Support section at www.tandberg.net It is also possible to send a fax or mail to the attention of: Product and Sales Support TANDBERG P.O. Box 92 1325 Lysaker Norway Tel: +47 67 125 125 Fax: +47 67 125 234

Page 9 of the TANDBERG Edge MXP user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 10 of the TANDBERG Edge MXP user manual
Page 10 · click to enlarge
Page 10

3.11.7 Display Snapshot 90 3.12 Conference Services 91 3.12.1 Request Floor and Release Floor 94 3.12.2 Conference Layout 95 3.12.3 Terminal Names 96 3.12.4 Chair Control 97 3.12.5 Assign Floor and Release Floor from Participant 98 3.12.6 View Site and End View 99 3.12.7 Disconnect Participant 100 3.12.8 Terminate Meeting 101 3.12.9 More about MultiSite (embedded MCU) 102 3.13 Control Panel 104 3.13.1 Diagnostics 105 3.13.2 System Information 106 3.13.3 Channel Status 107 3.13.4 Call Status 109 3.13.5 System Selftest 110 3.13.6 View Administrator Settings 111 3.13.7 IP Address Conflict Check 115 3.13.8 Warnings 116 3.13.9 Text Chat 118 3.13.10 Audio Demo 119 3.13.11 Administrator Settings 120 3.13.12 Restart 121 3.13.13 User Guide 122 4 Administrator Settings 123 4.1 General Settings 124 4.1.1 Language 125 4.1.2 System Name 126 4.1.3 International Name 127 4.1.4 Auto Answer 128 4.1.5 Phone Book Settings 129 4.1.6 External Services Settings 130 4.1.7 Permissions 131 4.1.8 Screen Settings 133 4.1.9 Software Options 139 4.1.10 Date and Time Settings 140 4.2 Menu Settings 141 4.2.1 Input Editor Language 142 4.2.2 Menu Timeout in Call 143 4.2.3 Menu on TV 144 4.2.4 Menu on PC 145 4.2.5 Balloon Help 146 4.2.6 Administrator Password 147 4.2.7 Kiosk Mode Settings 148 4.2.8 Startup 151 4.2.9 Icons 153 4.3 Presentation Settings 154 4.3.1 Presentation Start 155 4.3.2 H.239 156 4.3.3 Startup Video Source 157 4.3.4 Presentation Source 158 4.3.5 Snapshot Source 159 4.3.6 Auto-Display Snapshot 160 4.3.7 PIP Appearance 161 4.3.8 PIP Placing 162

Page 11 of the TANDBERG Edge MXP user manual — Table of contents
Page 11 · click to enlarge
Page 11

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 12 of the TANDBERG Edge MXP user manual — Table of contents
Page 12 · click to enlarge
Page 12

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 13 of the TANDBERG Edge MXP user manual — 1 Introduction
Page 13 · click to enlarge
Page 13

1 Introduction

The TANDBERG Maestro MXP provides high-end performance features, large monitors and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. Audio Quality High-performance audio provides a richer, more complete visual communication experience. The MPEG4 AAC-LD standard is used to provide true standards-based CD-quality, stereo audio. The Digital Natural Audio ModuleTM (DNAM), specifically designed for videoconferencing, provides higher fidelity sound for more natural sounding spoken-word. The DNAM features 250W of power. Users can record and send stereo audio from stereo presentation and playback sources using PCs, DVDs and VCRs using the proper cables. NEW Eliminate disturbance from GSM mobile phones and Blackberry devices Video Quality Features which ensure high quality video include:

ƒ Natural VideoTF which provides a 60 fields per second true interlaced picture. ƒ Support for H.264 in MultiSite, DuoVideo/H.239 and encryption. ƒ SXGA input and 2 x XGA output through DVI-I (analog or digital). ƒ WAVE II (Wide Angle View) Camera that delivers the widest angle of view in the industry. ƒ H.264 video compression up to 2Mbps. ƒ Support for native 16:9 Wide XGA monitors by increasing the resolution to 1280x768 (WXGA). ƒ Automatic use of WXGA format when ”VGA Monitor Format” is set to Wide. NEW High Definition (HD) Support on all TANDBERG MXP systems with a DVI input and output NEW High quality video and native 16:9 formats Network The system supports videoconferencing via both IP and ISDN networks. The bandwidth capabilities are:

ƒ up to 4Mbps* on IP ƒ up to 2Mbps* on ISDN ƒ up to 6Mbps* IP in MultiSite. ƒ SIP support, for both point-to-point and MultiSite*. If channels are dropped during a videoconferencing session, downspeedingTF automatically maintains connections without interruption.

Page 14 of the TANDBERG Edge MXP user manual — NEW
Page 14 · click to enlarge
Page 14

Security Secure ConferenceTF provides embedded encryption for both Point-to-Point and MultiSite call and ensures both privacy and security. The system is delivered with integrated Expressway™ firewall traversal technology. When used together with a TANDBERG Border Controller it enables:

ƒ Secure and seamless traversal of ANY firewall. ƒ No missing features when traversing the firewall – works with H.264, MPEG4 audio, encryption. ƒ Outside systems, such as home offices, to be part of the enterprise dial plan. ƒ Dialing to systems by URI, e.g. user@company.com. NEW

H.460, ITU Standardized firewall traversal, support

NEW

High security network authentication (802.1x) MultiSite* The optional embedded MultiSiteTF functionality can connect up to 6 video sites and 5 audio sites. Embedded MultiSite supports screen layouts such as VoiceSwitched, AutoSplit, 4 Split and 5+1 Split. The optional embedded MultiSite functionality supports any combination of ISDN and IP participants in a conference (up to the total). Superior quality and reliability in MultiSite calls is ensured by the systems support for:

ƒ DuoVideo/H.239 to provide for presenting full PC resolution information ƒ AES and DES encryption to provide security ƒ H.264 video algorithm to provide the best video at all bandwidths ƒ Rate matchingTF to support different call rates for all sites in a MultiSite ƒ TranscodingTF to support different protocols for all sites in a MultiSite. The TANDBERG videoconferencing system can also be used as an audio telephone bridge (assuming ISDN connection(s)). Presentations The Natural Presenter Package* (NPP) makes it possible to include PC presentations in videoconferences and comprises:

ƒ Digital ClarityTF which transmits exceptionally high-quality, native resolution video. ƒ Duo VideoTF/H.239 which allows participants at the far end to simultaneously watch a presenter on one screen and a live PC presentation in native resolution on a second monitor (up to SXGA on compatible monitors). ƒ PC PresenterTF which allows a PC connection via standard DVI/VGA cable supporting up to SXGA resolution. ƒ PC SoftPresenterTF which shows PC images via a LAN connection supporting XGA resolution. ƒ Auto Layout to automatically choose the best layout for the call. ƒ PC Zoom which allows the native resolution PC image to be zoomed in/out with the remote control to get SXGA resolution.

Page 15 of the TANDBERG Edge MXP user manual — 1 Introduction
Page 15 · click to enlarge
Page 15

Users can display video and presentations in the best layout based on the situation. Supported screen layouts are:

ƒ Picture in Picture (PiP) ƒ Picture outside Picture (PoP) ƒ Side by Side User interfaces A web-interface to the codec provides:

ƒ System management, diagnostics and software uploads. ƒ Text chat/closed captioning. ƒ Unicast Streaming – which allows broadcasting of audio/video via an IP network to a single compatible client (RealMedia™ or Apple Quicktime™) or streaming server. The On-Screen Menu:

ƒ Provides an easy interface for first-time users with symbols and descriptions. ƒ Builds upon the familiar current interface. NEW

Enhanced language support with Asian and non-Latin character text input in the menu for local language system names NEW

Support for new optional remote control

ƒ improved usability ƒ separate ordering NEW Simplified on-screen menu, Kiosk Mode, for special purposes The remote control has a simplified look and feel, an auto system wake-up when picked up, and large, easy-to-read keys. Interoperability The TANDBERG Maestro MXP is worldwide compatible with other ITU standards-based videoconferencing systems from many other vendors worldwide.

* - optional feature. To check which options are installed, select Control Panel - Diagnostics - System Information in the menu.

TF - TANDBERG First

Installation

Page 16 of the TANDBERG Edge MXP user manual — 1.1 At a Glance
Page 16 · click to enlarge
Page 16

1.1 At a Glance

TANDBERG Edge MXP — 1.1 At a Glance diagram (page 16)
Fig. 5 · 1.1 At a Glance

WAVE II Camera The main camera is mounted on top of the product. The main camera includes a high quality color camera with a fast pan/tilt/zoom action. The main camera is controlled by the system’s infrared remote control and operates pan/tilt, focus and zoom. Up to fifteen camera positions can be pre-stored using Camera Presets. A locking mechanism fixates the camera on top of the product. To release the locking mechanism and remove the camera push the grey button on the rear end of the camera stand

Page 17 of the TANDBERG Edge MXP user manual — 1.1 At a Glance
Page 17 · click to enlarge
Page 17
TANDBERG Edge MXP — 1.1 At a Glance diagram (page 17)
Fig. 6 · 1.1 At a Glance

Internal LCD Display The system has a built-in 5inch LCD designed to optimize system configuration and give the user access to menus and test video signals without attaching or powering an external display device. The LCD gives full control of all system settings and status. Below the LCD there are three system indicators, one red light indicating that the system is powered, one yellow light indicate that a call is active, and one green light indicate that the table microphones are muted. External display The TANDBERG Maestro is designed to give unlimited flexibility on the choice of display technologies and solutions to display video, and is an ideal solution for large meeting rooms which already are equipped with e.g. front projector and screen. For transferring video signal to one or more external display devices the Codec has the following video outputs: - DVI-I analog or digital interface - XGA - MiniDin, S-video - RCA / Phono, Composite video The usage of S-video gives the best quality for showing video of a far end, and use of DVI-I and XGA gives the best quality at PC presentation. Read user manual on the display device for configuration of settings at external display to meet setting at the Codec. Codec The codec is the heart of the system. Its main task is the compression of outgoing video, audio and data, the transmission of this information to the far end and the decompression of the incoming information - the name codec comes from a combination of the two words compression and decompression. The system is easily movable with four wheels and one handle. The codec is located inside the pedestal and behind the codec cover, which is easy removable. The pedestal stands on a solid base with an access hatch on the rear. On the inside of the hatch there are pockets for storing remote control and microphones. Pull the hatch to open. Inside the base there is room for additional equipment, e.g. a VCR/DVD, and for storage of cables. The Digital Natural Audio Module is built into the pedestal. Remote Control The remote control is used to control all functions of the system. If the screen saver is activated (black monitor), touching the remote control will automatically wake up the system. The remote control uses 4 AAA batteries. The system will tell you when batteries are running low. Change the batteries at the back of the remote control.

Installation

Page 18 of the TANDBERG Edge MXP user manual — 1.1 At a Glance
Page 18 · click to enlarge
Page 18

The reach of the remote control signal is 20 meters. For users sitting in an open plan office, this can cause problems. Use the little, white switch placed under the batteries to change the reach of the signal from 20 meters to 2 meters. This will prevent you from unintentionally controlling another video system, when you control your own system.

TANDBERG Edge MXP — 1.1 At a Glance diagram (page 18)
Fig. 7 · 1.1 At a Glance

Microphone The high quality table microphone is designed to be placed on a table during a videoconference. Up to three microphones can be connected. The ideal location for the microphone is on a flat surface at least 2m (6.5 ft) from the front of the system. The microphone cable should always point towards the system. The system will automatically equalize sound levels. Loud and soft voices are picked up and transmitted to the far end at approximately the same level.

TANDBERG Edge MXP — 1.1 At a Glance diagram (page 18)
Fig. 8 · 1.1 At a Glance

Digital Natural Audio Module The Digital Natural Audio Module (DNAM) is designed to enhance the audio quality during a videoconference. The DNAM provides natural sounding audio, as if the person or another sound source in the conference is present in the same room as you. The DNAM is a frequency-compensated sound system optimized for voice and other sounds that appears in modern videoconferencing. It is designed and dedicated specifically for videoconferencing requirements. The use of the highest quality speaker elements as well as proper amplifier- and software techniques minimizes signal distortion. The system will automatically detect the DNAM and optimize the audio output. Once detected the audio output will be in digital format (S/PDIF). The DNAM supports both analog and digital input. The DNAM amplifier and speaker cabinet are integrated directly into the Maestro pedestal.

Page 19 of the TANDBERG Edge MXP user manual — 1.1 At a Glance
Page 19 · click to enlarge
Page 19

The tracker is a small infrared remote control device made to steer the camera to any desired location within the room. Typically, several trackers would be used with each system. Each tracker has two buttons:

TANDBERG Edge MXP — 1.1 At a Glance diagram (page 19)
Fig. 9 · 1.1 At a Glance

ƒ One Single person button to point the camera at a specific person/location. ƒ One Group button to point the camera at all participants.

Beneath the battery in the tracker, there is a switch, which can be set to 16 different positions between 0 and F. For camera preset 10 to 15, the numbers A to F should be selected. For more information, contact your local TANDBERG representative.

Installation · TANDBERG Tracker

Page 20 of the TANDBERG Edge MXP user manual — 1.2 Menu Structure
Page 20 · click to enlarge
Page 20

1.2 Menu Structure

The menu structure is divided into two parts. The Main Menu is available for all users and contains all the functionality of the system. The Administrator Menu contains all the settings of the system. The Administrator Settings are accessible from the Main Menu by selecting Control Panel and Administrator Settings. Making changes to the Administrator Settings will change the behavior of the system. The menu structure for Main Menu and Administrator Settings is shown below.

TANDBERG Edge MXP — 1.2 Menu Structure diagram (page 20)
Fig. 10 · 1.2 Menu Structure
Page 21 of the TANDBERG Edge MXP user manual — 1.2 Menu Structure
Page 21 · click to enlarge
Page 21
TANDBERG Edge MXP — 1.2 Menu Structure diagram (page 21)
Fig. 11 · 1.2 Menu Structure

Installation

Page 22 of the TANDBERG Edge MXP user manual — 2 Installation
Page 22 · click to enlarge
Page 22

2 Installation

Precautions:

ƒ Never install communication wiring during a lightning storm. ƒ Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. ƒ Never touch uninstalled communication wires or terminals unless the telephone line has been disconnected at the network interface. ƒ Use caution when installing or modifying communication lines. ƒ Avoid using communication equipment (other than a cordless type) during an electrical storm. There may be a remote risk of electrical shock from lightning. ƒ Do not use the communication equipment to report a gas leak in the vicinity of the leak. ƒ Always connect the product to an earthed socket outlet. ƒ The socket outlet shall be installed near to the equipment and shall be easily accessible. ƒ Never install cables without first switching the power OFF. ƒ 1TR6 network type is not approved for connection directly to the telecommunications network. This network type is only to be used behind a PABX. ƒ X.21 network type is not approved for connection directly to the telecommunications network. This network type is only to be used together with already approved equipment, and is not meant for direct connections to the telecommunication networks. ƒ V.35/RS-449/RS-366 network type is not approved for connection directly to the telecommunications network. This network type is only to be used together with already approved equipment, and is not intended for direct connection to the telecommunication networks. This product complies with directives: LVD 73/23/EC, EMC 89/366/EEC, R&TTE 99/5/EEC

Page 23 of the TANDBERG Edge MXP user manual — 2.1 Unpacking and Mounting
Page 23 · click to enlarge
Page 23

2.1 Unpacking and Mounting

1 Unpacking The TANDBERG Maestro is delivered in one transport case with all components inside. Remove the case in the order shown on Figure 1.

TANDBERG Edge MXP — 2.1 Unpacking and Mounting diagram (page 23)
Fig. 12 · 2.1 Unpacking and Mounting

The accessories box contains:

ƒ Wave II camera ƒ 2x Table Microphones ƒ Remote Control and Tracker with batteries ƒ Documentation ƒ Cables for external displays

2 Mounting of the camera Mount the camera as shown in figure 2.

TANDBERG Edge MXP — 2.1 Unpacking and Mounting diagram (page 23)
Fig. 13 · 2.1 Unpacking and Mounting

Figure 2 3 Open the back of the system For access to the cables, microphones and remote control, remove the back cover as shown in Figure 3. The codec cover and the back cover are both held in place by magnets.

Installation

Page 24 of the TANDBERG Edge MXP user manual — 2.1 Unpacking and Mounting
Page 24 · click to enlarge
Page 24
TANDBERG Edge MXP — 2.1 Unpacking and Mounting diagram (page 24)
Fig. 14 · 2.1 Unpacking and Mounting
TANDBERG Edge MXP — 2.1 Unpacking and Mounting diagram (page 24)
Fig. 15 · 2.1 Unpacking and Mounting
Page 25 of the TANDBERG Edge MXP user manual — 2.2 Connecting Cables
Page 25 · click to enlarge
Page 25

2.2 Connecting Cables

TANDBERG Edge MXP — 2.2 Connecting Cables diagram (page 25)
Fig. 16 · 2.2 Connecting Cables

1. Power cable Find the right power cable that works for your country in the accessories box, and connect to power cable from base, and to an electrical distribution socket. 2. Microphone cable Connect the microphone cable to the microphone. 3. a) ISDN BRI Connect the ISDN cables to the ISDN sockets (S/T interface) provided by the network provider. The main ISDN number will be that number associated with the socket to which ISDN cable number 1 has been connected. 3. b) ISDN PRI If using the PRI interface, the E1/T1 cable should be connected to a CSU (Channel Service Unit). It is recommended that a CSU is used between the system and the PRI line from the network provider, see Appendix 8. 4. LAN cable To connect the system to a Local Area Network (LAN), connect the cable labeled "LAN Ethernet" to a suitable Ethernet port on the LAN.

5. External Display device a. S-video – connect cable from Codec Video Out 1 to External display b. DVI-I / VGA – find cable in accessories box and connect cable from DVI-I out single on the Codec to external display c. Composite – find cable in accessories box and connect cable from Video out 4 on the Codec to external display

Installation

Page 26 of the TANDBERG Edge MXP user manual — 2.2 Connecting Cables
Page 26 · click to enlarge
Page 26
6. PC Connect cable from DVI-I in PC from the Codec to PC.
Page 27 of the TANDBERG Edge MXP user manual — 2.3 Monitor Configuration
Page 27 · click to enlarge
Page 27

2.3 Monitor Configuration

Configuration of external display (projector)

ƒ Select 16:9 or 4:3 format on the projector. ƒ Make sure that the main projector is connected to the DVI-I Single output on the codec. Please refer to the projector user manual for further information.

Installation

Page 28 of the TANDBERG Edge MXP user manual — 2.4 System Configuration
Page 28 · click to enlarge
Page 28

2.4 System Configuration

The system must be configured for each installation. Configuration settings can be made via the system menu. If an external IMUX or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through the menu system using the arrow keys and OK. Remember to press the Save button on the bottom of each menu to save the changes. Press Cancel (x) to return to the previous Menu. See General Use for more information about how to use the menus and the remote control.

General configuration:

1. Open the General Settings menu Press OK/Menu to open the Main Menu, if not already displayed. Select Control Panel - Administrator Settings - General to open the General Settings menu.
TANDBERG Edge MXP — 2.4 System Configuration diagram (page 28)
Fig. 17 · 2.4 System Configuration
2. Language Press OK in the Language field and select the desired language from the list. 3. System Name / International Name* Enter a name in the System Name field using the number keys on the remote control, in the same way as with a mobile or cellular phone. Hold down the # key for one second to switch back and forth from numbers to alpha characters. 4. Auto Answer, Phone Book Settings, External Services Settings and Permissions

These settings may be left unchanged if no special needs are required. See chapter General Settings for more information.

Page 29 of the TANDBERG Edge MXP user manual — 2.4 System Configuration
Page 29 · click to enlarge
Page 29

5. Screen Settings When using wide screen (16:9) monitors, set TV Monitor Format to Wide (16:9). TANDBERG also recommends setting Picture Layout to Picture outside Picture when using 16:9 monitors. Picture outside Picture provides a display layout optimized for wide screen monitors. The display layout may be changed at any time using the Layout button on the remote control. 6. Software Options To activate options for the system, a new option key must be entered in the Software Options menu (see paperwork accompanying the system). The Presenter option key should be entered under “New Option Key”. Any bandwidth option key should be entered under “New Bandwidth Key”. For more information on these options, please contact your TANDBERG representative. 7. Date and Time Settings Select your preferred Date and Time Settings.

8. Save changes Remember to save any changes made in a menu by selecting the Save button on the menu line and pressing OK. Network configuration:
1. Open the Network menu Press OK/Menu to open the Main Menu, if not already displayed. Select Control Panel - Administrator Settings - Network to open the Network menu.
TANDBERG Edge MXP — 2.4 System Configuration diagram (page 29)
Fig. 18 · 2.4 System Configuration

2. ISDN configuration Set the Network type to the desired network. Specify the settings for the selected network in the relevant menu. Enabled but unused ISDN lines (i.e. lines not active) should be disabled. For details, follow the instructions in ISDN /External/Leased E1/T1. See also the examples in Appendix 9: Connecting the system to the Switched 56 network and in Appendix 10: Connecting the system to ISDN using NT1 network adapters. 3. LAN configuration Select LAN Settings in the Network menu and specify the necessary LAN settings according to the instructions from your LAN administrator. For details, follow the instructions in LAN Settings. If there is an H.323 Gatekeeper present on your LAN, refer to H.323 Settings as well.

Installation

Page 30 of the TANDBERG Edge MXP user manual — 2.4 System Configuration
Page 30 · click to enlarge
Page 30
4. Network Profiles Please refer to Network Profiles for details 5. Data Port Please refer to Data Port for details 6. Save changes Remember to save any changes made in the menu by selecting the Save button on the Menu line and pressing OK. * The International Name field is only visible if the system name contains Asian and non-Latin character text input.
Page 31 of the TANDBERG Edge MXP user manual — 3 General Use
Page 31 · click to enlarge
Page 31

3 General Use

Wake up the system

When the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond:

ƒ Make sure that the system is switched on. The red light indicator below the internal LCD should be turned on to indicate power on the system. If the system is not switched on, you need to remove the codec cover on the rear of the pedestal in order to access the power switch. Pull and lift the cover. The power switch is at the bottom of the Codec. If the picture does not appear on your external display, but on the 5’’ internal LCD:

ƒ Check that the external display is turned on. ƒ Check that video cable from Cesar is connected to external display ƒ Make sure that the video settings on the external display are correct, read the user manual for the external display.

TANDBERG Edge MXP — 3 General Use diagram (page 31)
Fig. 19 · 3 General Use
Page 32 of the TANDBERG Edge MXP user manual — 3.1 The Welcome Screen
Page 32 · click to enlarge
Page 32

3.1 The Welcome Screen

When the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The ISDN/IP numbers and the system name are displayed in the upper right corner. The ISDN Number and IP Number are the dial-in numbers of the system. The welcome screen provides you with the most important system information:

ƒ System Name ƒ Your ISDN Number ƒ Your IP Address or IP Number ƒ Indications of Missed Calls or Warnings if any It is possible to customize the text on the welcome screen. See Menu Settings for how to edit the welcome text.

TANDBERG Edge MXP — 3.1 The Welcome Screen diagram (page 32)
Fig. 20 · 3.1 The Welcome Screen
Page 33 of the TANDBERG Edge MXP user manual — 3.2 Using the Remote Control
Page 33 · click to enlarge
Page 33

3.2 Using the Remote Control

The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and press OK to navigate through the menus. The system’s most commonly used functions are also accessible directly from the remote control. The Infra Red (IR) sensor for the remote control is located in front of the WAVE II Camera. There is also a second IR-sensor located in the front of the Codec itself, which will be automatically enabled if the WAVE II Camera is not connected. The remote control (TRC 3)

TANDBERG Edge MXP — 3.2 Using the Remote Control diagram (page 33)
Fig. 21 · 3.2 Using the Remote Control

1. Mic Off turns your microphone on and off, see Mic off. 2. Arrow keys are used for navigation in the menu and for moving the camera* when the menu is hidden, see Navigation. 3. Volume + and – adjusts the Codec volume only and not the monitor's volume, see Volume + and -. 4. The Layout key toggles between full screen and different display layouts, see Layout. 5. Cancel takes you back one step in the menu system. Use Cancel to delete characters in an input field, see Navigation. Press and hold the Cancel key for 1 second to close the menu. 6. Press the Call key to place a call, see Make a Call. 7. Camera presets define specific camera positions. Move the camera to the desired position and press and hold a number key for 1 second to save the current camera position to that number key. To activate a preset whilst in a call, simply press and release that number key, see Camera Presets. 8. Snapshot takes a snapshot of your video only while you are in a call, see Take New Snapshot. 9. The Presentation key switches to a predefined presentation source. If the Presentation key is held down for 1 second then the Presentation video sources menu will appear, see Presentation Key. 10. Press OK/Menu to show the menu and to select menu items, see Navigation.

General Use

Page 34 of the TANDBERG Edge MXP user manual — 3.2 Using the Remote Control
Page 34 · click to enlarge
Page 34

11. Use Zoom + and – to zoom the camera in and out.* 12. Selfview displays your outgoing video. Press Selfview again to turn selfview off, see Selfview. 13. Use the Phone Book to store and recall video contacts for easy placement of calls, see Phone Book. 14. Use the red End Call key to end the current call. Pressing this key when not in a call will place the system in Standby mode, see End Call and Standby. 15. Number/Letter keys function in the same manner as with a mobile or cellular phone, see Number and Letter keys. 16. Press Touch tones when you are in a call and need to dial extension numbers etc. (instead of presets). Press the OK/Menu button to exit Touch Tones, see Touch tones.

*This does not apply to all systems with small integrated cameras.

Page 35 of the TANDBERG Edge MXP user manual — 3.2 Using the Remote Control
Page 35 · click to enlarge
Page 35

The remote control (TRC 4)**:

TANDBERG Edge MXP — 3.2 Using the Remote Control diagram (page 35)
Fig. 22 · 3.2 Using the Remote Control

1. Change video source. If possible, you will start open a Dual Stream. Press the video source button again to stop the dual stream. 2. Mic Off turns your microphone on and off, see Mic off. 3. Arrow keys are used for navigation in the menu and for moving the camera* when the menu is hidden, see Navigation. 4. Volume + and – adjusts the Codec volume only and not the monitor's volume, see Volume + and -. 5. The Layout key toggles between full screen and different display layouts, see Layout. 6. Cancel takes you back one step in the menu system. Use Cancel to delete characters in an input field, see Navigation. Press and hold the Cancel key for 1 second to close the menu. 7. Press the Call key to place a call, see Make a Call. 8. Number/Letter keys function in the same manner as with a mobile or cellular phone, see Number and Letter keys. Camera presets define specific camera positions. Move the camera to the desired position and press and hold a number key for 1 second to save the current camera position to that number key. To activate a preset whilst in a call, simply press and release that number key, see Camera Presets. 9. Press Preset + a number to activate a preset. 10. Press the Services button to open the Services menu. 11. The Presentation key switches to a predefined

General Use

Page 36 of the TANDBERG Edge MXP user manual — 3.2 Using the Remote Control
Page 36 · click to enlarge
Page 36

presentation source. If the Presentation key is held down for 1 second then the Presentation video sources menu will appear, see Presentation Key. 12. Press OK/Menu to show the menu and to select menu items, see Navigation. 13. Use Zoom + and – to zoom the camera in and out.* 14. Selfview displays your outgoing video. Press Selfview again to turn selfview off, see Selfview. 15. Use the Phone Book to store and recall video contacts for easy placement of calls, see Phone Book. 16. Use the red End Call key to end the current call. Pressing this key when not in a call will place the system in Standby mode, see End Call and Standby. 17. Snapshot takes a snapshot of your video only while you are in a call, see Take New Snapshot. 18. Press Touch tones when you are in a call and need to dial extension numbers etc. (instead of presets). Press the OK/Menu button to exit Touch Tones, see Touch tones. 19. Pressing Far End turns Far End control on and off. 20. Press the Help button to open the User Guide menu.

*This does not apply to all systems with small integrated cameras. ** Ordered separately

Page 37 of the TANDBERG Edge MXP user manual — 3.2.1 Navigation
Page 37 · click to enlarge
Page 37

3.2.1 Navigation

TANDBERG Edge MXP — 3.2.1 Navigation diagram (page 37)
Fig. 23 · 3.2.1 Navigation

Arrow keys and OK Navigate in the menu with the arrow keys on the remote control. The orange selector on screen shows the selected item. Press OK to select.

Cancel key In the main menu, pressing Cancel (X) will hide the menu. If the menu is hidden, bring it back with OK. In other menus, pressing Cancel (X) takes you one step back. In an input field, pressing Cancel (X) will delete characters/numbers to the left.

Back/Cancel button The X button in the menu corresponds with the X key on the remote.

General Use

Page 38 of the TANDBERG Edge MXP user manual — 3.2.2.1 Local PC Display
Page 38 · click to enlarge
Page 38

3.2.2 Selfview

The term “Selfview” means the outgoing image. In a normal call using the main camera, this is the image of yourself. The Selfview button toggles the images between Far End, Selfview and Dual Video (if any). How to use Selfview:

1. Outside a call, pressing the Selfview button will switch between the near end video and a black screen/logo on the main monitor. 2. In a point to point call, press the Selfview button once to switch from far end video to near end video to see a full screen picture of the outgoing video. Press Selfview again to go back to normal. 3. In a point to point call with a dual video stream, the dual stream is displayed in the big picture. Press the Selfview button to toggle to the Near End picture, then the Far End picture, and finally back to the dual stream. The above behaviour is similar for both single monitor systems and dual monitor systems. Selfview applies to the main monitor.

3.2.2.1 Local PC Display

When using the screen as your PC screen, it is recommended to set Local PC Display to On, see Screen Settings. That implies that you can display your PC locally while having a videoconference, and you can keep on working without having the Far End participant viewing your PC screen. Note that this applies to single monitor systems only. It is also recommended to keep the Auto Layout setting On (default) to get a suitable layout when toggling from Local PC Display mode to standard conference mode. Use the Selfview button to toggle between Local PC Display mode and standard videoconference mode. An indicator tells you that your PC image is displayed locally.

Page 39 of the TANDBERG Edge MXP user manual — 3.2.2 Selfview
Page 39 · click to enlarge
Page 39

Example: You are using the system as a PC and get an incoming call. When the setting “Use Screen as Local PC monitor” is On, you will keep your PC image displayed locally and the incoming call pops up in a PIP or as smaller images in a 1+3 layout, depending on your system. You will see Local PC displayed in the big picture and Far End and/or Near End (your self) displayed in smaller pictures. Press the Selfview button to switch to standard conference mode. The Local PC image is no longer displayed and Far End is displayed in the big picture or full screen. Press Selfview again to see Near End. Pressing Selfview a third time will bring back the Local PC display mode.

General Use

Page 40 of the TANDBERG Edge MXP user manual — 3.2.3.3 Auto Layout
Page 40 · click to enlarge
Page 40

3.2.3 Layout

The layout of the screen can either be shown as Picture in Picture (PIP) or Picture outside Picture (POP) when displaying more than one video image. The behavior of the Layout button is dependent on the Picture Layout setting in Screen Settings.

3.2.3.1 Picture in Picture

When Picture Layout is set to PIP, the Layout button makes it possible to see a second image in a smaller view in one of the corners of the screen. The second image will be placed on top of the main image. The user can decide in which corner the second image is to be displayed.

3.2.3.2 Picture outside Picture

When Picture Layout is set to POP, the Layout button makes it possible to see up to three images in a composition optimized for wide screens. The second image can be displayed either as a side-by-side the main image (1+1) or smaller images next to the main image (1+2 and 1+3). Press the Layout button once to get side-by-side view (1+1). Press again to get the layouts 1+2 and 1+3, and finally go back to full screen view. You can also go back to full screen directly by pressing and holding Layout for 1 second. It is recommended to use Picture outside Picture for wide screen monitor systems.

3.2.3.3 Auto Layout

The system will automatically choose the best layout for your call. The layouts vary depending on how many participants there are and if you use a dual video source or not. You can however always change layout manually with the Layout button. Auto Layout applies when you open or close a dual stream, or add or disconnect participants. Auto Layout also includes the former automatic PIP. That implies that PIP will automatically be shown when suitable, e.g. to display selfview when you move your near end camera. The automatic PIP times out after a couple of seconds. If Auto Layout is Off you will get no automatic layout changes during a call and the user must manually control the images with the Layout button. Auto Layout is default On. To turn Auto Layout Off, go to Screen Settings.

Page 41 of the TANDBERG Edge MXP user manual — 3.2.4 Mic Off
Page 41 · click to enlarge
Page 41

3.2.4 Mic Off

To mute the microphone during a call, press the Mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic off button one more time will activate the microphone again. A green LED below the internal LCD at the system will be turned on when the microphone is off. Note that Mic off will mute all microphone inputs and audio 4 input.

When an incoming call is answered, the microphone may be in the off state because the Auto Answer setting is On+Mic off, see Auto Answer. The icon will start to flash when you start speaking. Remember to turn the microphone on before a meeting.

General Use

Page 42 of the TANDBERG Edge MXP user manual — 3.2.5 Volume + and -
Page 42 · click to enlarge
Page 42

3.2.5 Volume + and -

Press the Volume key to adjust the volume level. An on-screen indicator will show the current level.

TANDBERG Edge MXP — 3.2.5 Volume + and - diagram (page 42)
Fig. 24 · 3.2.5 Volume + and -
Page 43 of the TANDBERG Edge MXP user manual — 3.2.6 Number and Letter keys
Page 43 · click to enlarge
Page 43

3.2.6 Number and Letter keys

Pressing a number key when outside a call will bring up the call menu. When in a call, the number keys are used for Camera Presets. Press a number and go to the corresponding Camera Preset (see Camera Presets). However, when accessing an input field where numbers are required, the system automatically goes to number mode and numbers can be dialed with the number keys as usual. When accessing an input field where letters are required, the system automatically goes to letter mode. Writing letters works like on a mobile phone. Press the key that corresponds to your desired letter. Press the key as many times as needed to get the right letter. Change to lower or back to upper case letters with the a/A key, and space with the 0 _ key. To write numbers in a text input field, press the button through all the letters. Press once more and the number will appear.

Example: How do I write "System 123" in the System Name input field (in General in Administrator Settings)? Press the 7-key four times to get an "S". Press the #-key once to switch between upper case and lower case letters. Press the 9-key three times to get a "y". Press the 7-key four times to get an "s". Press the 8-key once to get a "t". Press the 3-key twice to get an "e". Press the 6-key once to get an "m". Press the 0-key once to get space. Press the 1-key three times to get a "1". Press the 2-key four times to get a "2". Press the 3-key four times to get a "3".

General Use

Page 44 of the TANDBERG Edge MXP user manual — 3.2.7 Touch Tones
Page 44 · click to enlarge
Page 44

3.2.7 Touch Tones

To activate dialing touch tones during a call, press the Touch tones button. Otherwise the number keys will activate the corresponding camera presets. An indicator will let you know that Touch tones are enabled. Finish with OK to exit Touch tone mode.

Page 45 of the TANDBERG Edge MXP user manual — 3.3 On-screen Indicators
Page 45 · click to enlarge
Page 45

3.3 On-screen Indicators

The system has a number of icons signaling different settings:

Microphone Off This indicator is shown when the microphone is turned off. Press the Mic off button again to turn the microphone back on, see Mic Off for details.

Volume Off This indicator is shown when the volume is turned off. Press Volume + to turn the volume back on, see Volume + and - for details.

Secure Conference, AES This double padlock indicator is shown when AES encryption (Secure Conference) is active, see Security for details.

Secure Conference, DES This padlock indicator is shown when DES encryption (Secure Conference) is active, see Security for details.

Not Secure Conference This open padlock indicator is shown during the initialization phase for AES or DES encryption. During this period the call is not secure, see Security for details.

Bad Network This indicator appears if the system detects network anomalies like packet loss (5%), jitter (200ms) etc., during a call. Open the menu by pressing the OK/Menu button and select the warnings icon too see details.

Floor This indicator is shown when you are displayed in full screen in a multipoint conference, see Request Floor and Release Floor for details.

General Use

Page 46 of the TANDBERG Edge MXP user manual — 3.3 On-screen Indicators
Page 46 · click to enlarge
Page 46

Telephone This indicates that there is a telephone participant in the conference. The displayed number indicates how many telephone participants there are in the conference.

Page 47 of the TANDBERG Edge MXP user manual — 3.4 Using the Menu
Page 47 · click to enlarge
Page 47

3.4 Using the Menu

TANDBERG Edge MXP — 3.4 Using the Menu diagram (page 47)
Fig. 25 · 3.4 Using the Menu

Main menu outside a call and in a call. Press the Menu button on the remote control to display the menu. The menu contains all functions needed in order to control the system.

General Use

Page 48 of the TANDBERG Edge MXP user manual — 3.4 Using the Menu
Page 48 · click to enlarge
Page 48

The menu contains the following items:

ƒ Make a Call/Add Another Call ƒ Standby/End Call ƒ Camera Control ƒ Presentation ƒ Conference Services ƒ Control Panel ƒ Close See Menu Structure for a full overview of the menu. The functions of the menu are displayed as icons. The currently selected icon is marked by an orange square, and the name of the corresponding function is displayed on the line above, see the figure above. Press the OK button to activate the currently selected function. The menu automatically times out after 15 seconds if not used, see Menu timeout. Press the Menu button to bring it back. It is also possible to hide the menu manually by pressing the Cancel button on the remote control or select the Close icon in the menu.

* Systems with no Camera Control icon available may have a Far End Control icon present when in a call and Far End Control is possible.

Page 49 of the TANDBERG Edge MXP user manual — 3.5 Make a Call
Page 49 · click to enlarge
Page 49

3.5 Make a Call

Display the call menu by either:

1. Select Make a Call from the menu, or 2. Press the green Call button on the remote control The TANDBERG system can make both Video calls and Telephone calls. Call Settings specifies the quality of the call. It is possible to alter the default call settings for the current call if required. The Default Call Settings are defined in Control Panel - Administrator Settings - Call Quality - Default Call Settings. It is possible to start Streaming from this menu. For setting up a MultiSite conference, see Add Call for more details.

TANDBERG Edge MXP — 3.5 Make a Call diagram (page 49)
Fig. 26 · 3.5 Make a Call

General Use

Page 50 of the TANDBERG Edge MXP user manual — 3.5.1 Place Video Call
Page 50 · click to enlarge
Page 50

3.5.1 Place Video Call

In the Make a Call menu, enter the Dial Number either:

1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant. When dialing manually, toggle between ABC/abc by pressing the # button on the remote control and between abc/123 by holding the # button for one second. Use a star as separator in IP addresses. If a system is registered on a gatekeeper or border controller with DNS support, there are several ways to call into the system:

ƒ ƒ ƒ ƒ @ ƒ @ See H.323 Settings for details. Place the call by either:

1. Press OK on the remote control so that the Place Video Call icon is selected, and press OK once again, or 2. Use the arrow button on the remote control to select the Place Video Call icon and press OK, or 3. Press the green call button on the remote control. Note that the call will be set up as a telephone call if the Call Type in Call Settings is set to Telephone Call. See Default Call Settings for more details.

TANDBERG Edge MXP — 3.5.1 Place Video Call diagram (page 50)
Fig. 27 · 3.5.1 Place Video Call
Page 51 of the TANDBERG Edge MXP user manual — 3.5.2 Place Telephone Call
Page 51 · click to enlarge
Page 51

3.5.2 Place Telephone Call

In the Make a Call menu, enter the Dial Number either:

1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant, see Phone Book for details. When entering a Dial Number manually, toggle between abc/123 by pressing the # button on the remote control for one second. Use a star as separator in IP addresses. Place the call by either:
1. Press OK on the remote control, select the Place Telephone Call icon and press OK once again, or

General Use

Page 52 of the TANDBERG Edge MXP user manual — 3.5.3 Add Call
Page 52 · click to enlarge
Page 52

3.5.3 Add Call

(Optional feature) Conference systems with built-in MultiSite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a conference with two or more participants In the Make a Call menu, enter the Dial Number either:

1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant, see Phone Book for details. It is also possible to select a predefined MultiSite entry, see New MultiSite Contact . 3. Press OK on the remote control. Add another participant to the conference by either:

1. Select the Add Video Call icon if the next participant is using a video system, and press OK, or 2. Select the Add Telephone Call icon if the next participant is using a telephone system, and press OK. A new entry is now displayed in the call list. Enter the number as described above. It is also possible to set up a list of all the wanted conference participants by selecting the Add Video Calls and Add Telephone Calls the desired number of times, and enter their numbers afterwards. Place a MultiSite call:

1. If the call is a mixed conference with both video and telephone participants, select the Place Video Call icon, or 2. If the call is a conference with telephone participants only, select the Place Telephone Call icon. Add participant(s) during a conference Display the call menu during a call by either:
1. Select Make a Call from the menu, or 2. Press the green Call button on the remote control Enter the new participants in the same way as described above.
Page 53 of the TANDBERG Edge MXP user manual — 3.5.3 Add Call
Page 53 · click to enlarge
Page 53
TANDBERG Edge MXP — 3.5.3 Add Call diagram (page 53)
Fig. 28 · 3.5.3 Add Call

General Use

Page 54 of the TANDBERG Edge MXP user manual — 3.5.4 Call Settings
Page 54 · click to enlarge
Page 54

3.5.4 Call Settings

The Call Settings specifies the quality of the call. Each call will be set up with the Default Call Settings if the settings are not altered. In this case the field is labeled Default Call Settings. If the settings for some reason are altered for the current participant in the current call, the name of the field will be changed to reflect this. Usually it is not necessary for the user to alter the settings. The Default Call Settings are defined in Control Panel - Administrator Settings - Call Quality - Default Call Settings. When setting up a call in the Make a Call menu:

1. Select the Default Call Settings field for the participant and press the OK button on the remote control. 2. Make desired changes to Call Type, Network, Bandwidth and Restrict (56k). If this is to be the new default call settings, select Set as Default in the menu. 3. Select the OK icon and press the OK button on the remote control. The name of the Call Settings field will reflect the changes made.
TANDBERG Edge MXP — 3.5.4 Call Settings diagram (page 54)
Fig. 29 · 3.5.4 Call Settings

It is possible to make the changes made to the Call Settings default by selecting Set as Default and OK. These settings will now be the default settings for all future manually dialed calls. These settings are also available in the menu Control Panel - Administrator Settings - Call Quality - Default Call Settings.

Page 55 of the TANDBERG Edge MXP user manual — 3.5.5 Streaming
Page 55 · click to enlarge
Page 55

3.5.5 Streaming

Streaming lets you broadcast your meeting to participants on the web. The web participants can listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if MultiSite), selfview, far end and DuoVideo streams are accessible via http. See Appendix 6 for descriptions of the possible snapshot files. How to use Streaming:

1. Choose Streaming from the Call Menu to open the Streaming menu. 2. Press Start Streaming from the menu line. An indicator will appear on the screen when streaming is activated. 3. Press Stop Streaming to end streaming. Streaming will also end when you disconnect the call. 4. Press Streaming Settings if you want to change streaming settings (see Streaming Settings below) How to view streaming from a PC:
1. After streaming is started, an easy way to view the streamed audio/video is to start your Web browser and enter the IP-address of the streaming system. 2. After the Web page of the system is shown, click on Streaming. Alternatively, enter http://<codec/ip-address>/showstream.ssi Streaming Settings

Address is defined as the IP-address of a streaming client, streaming server or a multicast address. Giving an address in the range 224.0.0.1- 239.255.255.255 will broadcast the stream to any host that has joined the specified multicast group. Specifying normal broadcast address 255.255.255.255 will broadcast to any members on the LAN.

If several codec’s are streaming to the same IP-address, different ports have to be used in order for the client to know which stream to receive. If the first codec streams on port 2240 and the second codec on port 2250, the client has to specify which port to listen to. Video is transmitted on the specified port; audio is transmitted on the port number 4 greater than the specified video port, in this case 2244 and 2254.

This is used for streaming data to limit how many routers the data should pass before it is rejected. If TTL is set to 2, data will not traverse more than 2 router hops.

Show 4 more labels / short text on this page
General Use · Address · Address Port · TTL/Router Hops
Page 56 of the TANDBERG Edge MXP user manual — 3.5.5 Streaming
Page 56 · click to enlarge
Page 56

ƒ Auto: Enables streaming of both local and far end video. Selection of which site to be streamed is done using voice switching (the site that speaks is streamed). ƒ Local: Only the local video will be streamed. ƒ Remote: Only the far end video will be streamed. Local and far end audio is always streamed.

ƒ On: Streaming can be started from external user interfaces like the Web-browser or Telnet session. ƒ Off: Streaming can only be started from the Video Conferencing System User Interface using the remote control, or by using the Data port. This will prevent activation of streaming using Web browser or Telnet sessions. See also Password section below

ƒ On: The codec will send announcement packets to the network that it is streaming. This enables a streaming client (e.g. a PC) to connect to the codec’s streaming session. Used by Cisco IP/TV. ƒ Off: No announcement packets will be transmitted.

Defines the Video streaming rate from the system. Range is 16 kbps - 320 kbps. In addition, audio (G.711) streaming rate is 64 kbps, providing a maximum streaming rate of 384 kbps.

Set password so that only participants entering correct password will be able to view the streaming session. Entering a password will prevent unauthorized people from accessing the streaming session.

*The streaming source setting is not available when streaming only is supported outside a call.

Show 5 more labels / short text on this page
Streaming Source* · Allow Remote Start · Announcements · Video Rate · Streaming Password
Page 57 of the TANDBERG Edge MXP user manual — 3.6 Answer an incoming call
Page 57 · click to enlarge
Page 57

3.6 Answer an incoming call

How to answer an incoming call:

ƒ To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call:

ƒ To reject an incoming call, select the Reject icon and press the OK button, or press the End Call button on the remote control.

TANDBERG Edge MXP — 3.6 Answer an incoming call diagram (page 57)
Fig. 30 · 3.6 Answer an incoming call

Incoming calls will connect automatically if Auto Answer is set to On, see Auto Answer for details. When idle, the system will accept all incoming calls as long as Incoming MCU Calls and Incoming Telephone Calls are set to On, see Permissions for details. Also, Do Not Disturb must not be activated, see Do Not Disturb for more details.

General Use

Page 58 of the TANDBERG Edge MXP user manual — 3.7 End Call
Page 58 · click to enlarge
Page 58

3.7 End Call

How to end a call:

ƒ Press the red End Call button on the remote control, or ƒ Press the Menu button on the remote control to display the menu and select End Call.

When the End Call dialog box is displayed either:

ƒ Press the red End Call button on the remote control again, or ƒ Press the OK button to confirm that the call is to be ended.

TANDBERG Edge MXP — 3.7 End Call diagram (page 58)
Fig. 31 · 3.7 End Call

How to end a MultiSite call: In the list of participants:

TANDBERG Edge MXP — 3.7 End Call diagram (page 58)
Fig. 32 · 3.7 End Call
Page 59 of the TANDBERG Edge MXP user manual — 3.8 Standby
Page 59 · click to enlarge
Page 59

3.8 Standby

The system will automatically go to Standby mode when it is not in use. In standby mode, the screen(s) are black. It is however still possible to receive incoming calls. How to enter standby mode manually:

ƒ Select Standby from the menu and select Standby Now, or ƒ Press the End Call button on the remote control twice. How to exit standby mode:

ƒ When the system is in standby, pick up the remote control, or press any of its keys to activate the system again. The standby mode of the system should be enabled if the system is to be left idle.

If the system is set for Use screen as Local PC monitor, see Screen Settings, the Standby mode will be disabled when the codec detects a video signal from the PC. If the PC video signal is not detected, the standby mode will be re-enabled.

It is possible to postpone the system from entering standby mode for 1 hour or 3 hours, see Delay Standby for 1 hour and Delay Standby for 3 hours.

General Use

Page 60 of the TANDBERG Edge MXP user manual — 3.8.1 Delay Standby for 1 hour
Page 60 · click to enlarge
Page 60

3.8.1 Delay Standby for 1 hour

Delay Standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone the system from entering standby mode for 3 hours, see Delay Standby for 3 hours.

Page 61 of the TANDBERG Edge MXP user manual — 3.8.2 Delay Standby for 3 hours
Page 61 · click to enlarge
Page 61

3.8.2 Delay Standby for 3 hours

Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone the system from entering standby mode for 1 hour, see Delay Standby for 1 hour.

General Use

Page 62 of the TANDBERG Edge MXP user manual — 3.8.3 Do Not Disturb
Page 62 · click to enlarge
Page 62

3.8.3 Do Not Disturb

To prevent the system from accepting any incoming calls, activete the Do Not Disturb function. The caller will hear a busy tone when calling the system. The monitor will be black when Do Not Disturb is active, see figure below. This is useful when using the display for a presentation as a local PC monitor and you do not wish any incoming calls during the presentation. End Do Not Disturb by pressing any key on the remote control.

TANDBERG Edge MXP — 3.8.3 Do Not Disturb diagram (page 62)
Fig. 33 · 3.8.3 Do Not Disturb
Page 63 of the TANDBERG Edge MXP user manual — 3.9 Phone Book
Page 63 · click to enlarge
Page 63

3.9 Phone Book

The Phone Book is available via the Phone Book button on the remote control or from the Make a Call menu. Using the Phone Book is time saving and prevents the user from inadvertently calling the wrong number. The contacts are sorted alphabetically. The contact names are displayed in the list and the telephone or video numbers, bandwidth and net profiles of the selected contact are displayed at the bottom line. Navigate up and down in the Phone Book with the arrow keys on the remote control. Use the letter keys to search through the contacts beginning with the typed letter. The functions in the Phone Book are available when pressing the left arrow key on the remote control, and then the up and down arrow keys. Note that the last selected contact will be marked. When selecting Phone Book the phone book opens showing the folders Placed Calls, Missed Calls, Received Calls and My Contacts. Global Contacts are listed below these folders.

TANDBERG Edge MXP — 3.9 Phone Book diagram (page 63)
Fig. 34 · 3.9 Phone Book

The following information is available from the Phone Book:

ƒ Placed Calls ƒ Missed Calls ƒ Received Calls ƒ My Contacts ƒ Global Contacts

General Use

Page 64 of the TANDBERG Edge MXP user manual — 3.9.1 Call Log
Page 64 · click to enlarge
Page 64

3.9.1 Call Log

The Call Log lists Placed Calls, Missed Calls and Received Calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the contacts listed are available in the phone book, the names will be displayed instead of the numbers. Placed Calls lists all outgoing calls, Missed Calls lists the calls that are not accepted and Received Calls lists all incoming calls. The calls in the lists are marked with these icons:

missed calls The following buttons are available from these folders :

ƒ Call Now ƒ Copy to My Contacts ƒ Delete ƒ Delete All ƒ Cancel How to make a call using the call lists:

1. Select a number from the list. 2. Press the green Call button on the remote control, or press the left arrow key to select the Call Now icon, followed by OK. The call will be set up as a video call or a telephone call depending on the selected contact. Alternatively, press the OK button when the contact is selected. The Make a Call menu will then be displayed with the name of the contact in the Dial Number field, and the Call Settings field will reflect the call settings for this contact. It is possible to alter the call settings before placing the call. The call will be set up as a video call or a telephone call as described in Make a Call. 3. Wait for the call to connect. How to delete numbers in the call lists do one of the following:

ƒ Choose the Delete button to delete a selected contact from the call list. ƒ Choose the Delete All button to delete all contacts listed in the call list. Note that you will not delete contacts from the Phone Book if you delete them from the call lists.

outgoing calls · incoming calls

Page 65 of the TANDBERG Edge MXP user manual — 3.9.2 My Contacts
Page 65 · click to enlarge
Page 65

3.9.2 My Contacts

My Contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My Contacts can store up to 200 contacts. How to make a call using My Contacts:

1. Find the desired contact using the arrow keys or searching on the first letter with the letter keys. 2. Press the green Call button on the remote control, or press the left arrow key to select the Call Now icon, followed by OK. The call will be set up as a video call or a telephone call depending on the settings made when storing the contact. Alternatively, press the OK button when the contact is selected. The Make a Call menu will then be displayed with the name of the contact in the Dial Number field, and the Call Settings field will reflect the call settings for this contact. It is possible to alter the call settings before placing the call. The call will be set up as a video call or a telephone call as described in Make a Call. 3. Wait for the call to connect.

TANDBERG Edge MXP — 3.9.2 My Contacts diagram (page 65)
Fig. 35 · 3.9.2 My Contacts

General Use

Page 66 of the TANDBERG Edge MXP user manual — 3.9.2 My Contacts
Page 66 · click to enlarge
Page 66

The following functions are available from My Contacts:

ƒ Call Now ƒ New Contact ƒ New MultiSite Contact ƒ Edit Contact ƒ Delete Contact ƒ Close

Page 67 of the TANDBERG Edge MXP user manual — 3.9.2.1
Page 67 · click to enlarge
Page 67

3.9.2.1

Add New Contact

The New Contact function is available from My Contacts. Add a new contact to My Contacts by:

1. Select the New Contacts button to open the New Contacts dialog box. 2. Enter Name by using the letter keys on the remote control. Input will automatically be interpreted as letters. Toggle between capital letters and small letters by pressing the # button on the remote control. The maximum name length is 30 characters. For numbers, press the # button for one second. 3. Enter Number by using the number keys on the remote control. Input will automatically be interpreted as numbers. The maximum number length is 60 numbers. Use a star as separator in IP addresses. For letters, press the # button for one second. 4. Alter the default setting of Call Type if necessary. 5. Alter the default setting of Network if necessary. 6. Alter the default setting of Bandwidth if necessary. For bandwidth 2x64 kbps or 2x56 kbps, two numbers are required, see Default Call Settings for more details. 7. Alter the default setting of Restrict (56k) if necessary. 8. Press OK to save.

TANDBERG Edge MXP — 3.9.2.1 diagram (page 67)
Fig. 36

General Use

Page 68 of the TANDBERG Edge MXP user manual — 3.9.2.2
Page 68 · click to enlarge
Page 68

3.9.2.2

New MultiSite Contact

(Optional feature*) The New MultiSite Contact function is available from My Contacts. It is possible to pre-define the participants of a conference meeting as a MultiSite Contact. All participants in the MultiSite Contact will then be connected automatically instead of having to call the participants one by one. My Contacts can hold up to 50 MultiSite Contacts. The MultiSite Contacts consist of participants that are already stored in My Contacts. It is possible to have up to a total of 6 video participants and 5 telephone participants in a meeting. How to define a New MultiSite Contact:

1. Open the Phone Book via the Phone Book button on the remote control or in the Make a Call menu. 2. Select the New MultiSite Contact icon. The New MultiSite Contact dialogue box is displayed. 3. Enter a name of the MultiSite Contact, and press OK on the remote control. 4. Select Add Participant. The content of the Local Phone Book is displayed. Find the desired contact and press the OK button on the remote control. Repeat until all the desired participants are selected. 5. Press OK to save the MultiSite Contact.

Page 69 of the TANDBERG Edge MXP user manual — 3.9.2.2 New MultiSite Contact
Page 69 · click to enlarge
Page 69
TANDBERG Edge MXP — 3.9.2.2 New MultiSite Contact diagram (page 69)
Fig. 37 · 3.9.2.2 New MultiSite Contact

Bandwidth for a MultiSite Contact call When calling a MultiSite Contact, the system will try to call the participants with their specified bandwidths. If the total bandwidth exceeds the system's maximum bandwidth, the system will downspeed and distribute the available bandwidth equally among all the participants.

Example: In a MultiSite Contact there is one participant with bandwidth 256kbps and one participant with bandwidth 384kbps. 512kbps is the maximum bandwidth of the system. The two participants' bandwidth exceeds the maximum bandwidth. The system will then downspeed so that each participant connects with equal bandwidth, i.e. 512kbps/2 = 256kbps.

* The MultiSite option is not available on the TANDBERG 550 MXP, TANDBERG 770 MXP and TANDBERG 1000 MXP

General Use

Page 70 of the TANDBERG Edge MXP user manual — 3.9.2.3
Page 70 · click to enlarge
Page 70

3.9.2.3

Edit Contact

The Edit Contact function is available from My Contacts. How to edit a contact in the Local Phone Book:

1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the Edit Contact icon is selected. 3. The current settings for this contact are displayed in a dialogue box. Alter the wanted settings. 4. Press OK to save. If the altered contact is part of a MultiSite Contact*, the contact will be updated in the MultiSite Contact automatically.
TANDBERG Edge MXP — 3.9.2.3 diagram (page 70)
Fig. 38

* The MultiSite option is not available on all systems.

Page 71 of the TANDBERG Edge MXP user manual — 3.9.2.4
Page 71 · click to enlarge
Page 71

3.9.2.4

Delete Contact

The Delete Contact function is available from My Contacts. How to delete a contact:

1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the Delete Contact icon is selected. The Delete Contact dialogue box is displayed. 3. Confirm by pressing the OK button again.
TANDBERG Edge MXP — 3.9.2.4 diagram (page 71)
Fig. 39

General Use

Page 72 of the TANDBERG Edge MXP user manual — 3.9.3 Global Contacts
Page 72 · click to enlarge
Page 72

3.9.3 Global Contacts

When selecting Phone Book the phone book opens showing the Global Contacts* or the Corporate Directory** below the folders Placed Calls, Missed Calls, Received Calls and My Contacts. These contacts cannot be changed locally by the system, only from the management system. If there is a need to modify the number or any settings of a contact before making a call, select the contact and press OK on the remote control. The Make a Call menu is displayed and the settings can be altered before placing the call. The changes are not saved. How to make a call using Global Contacts:

1. Find the desired contact using the arrow keys or searching on the first letter with the letter keys or use the search function described in Search. 2. Press the green Call button on the remote control, or press the left arrow key to select the Call Now icon, followed by OK. The call will be set up as a video call or a telephone call depending on the settings made when storing the contact. Alternatively, press the OK button when the contact is selected. The Make a Call menu will then be displayed with the name of the contact in the Dial Number field, and the Call Settings field will reflect the call settings for this contact. It is possible to alter the call settings before placing the call. The call will be set up as a video call or a telephone call as described in Make a Call. 3. Wait for the call to connect. From Global Contacts the following functions are available:

ƒ Call Now ƒ Up one Level ƒ Search ƒ Copy to My Contacts ƒ Close * The Global Contacts are stored locally on the ftp-server of the system. This will include the first 400 entries of the Corporate Directory, and will not contain any folders. This directory is hidden from the user as long as the system is able to fetch the Corporate Directory, otherwise the Global Contacts will be displayed. ** The Corporate Directory is available if the system is connected to an external management system like the TANDBERG Management Suite (TMS) and if it is enabled in Phone Book Settings.

Page 73 of the TANDBERG Edge MXP user manual — 3.9.3.1 Up one Level
Page 73 · click to enlarge
Page 73

3.9.3.1 Up one Level

Global Contacts can be arranged in a tree structure with several sub folders. Use the Up one Level button to navigate up in the tree structure. When a search in the Global Phone Book is made, by using the Search function, only contacts matching the search text are displayed. Select the Up one Level button to return back to the alphabetical list.

General Use

Page 74 of the TANDBERG Edge MXP user manual — 3.9.3.2
Page 74 · click to enlarge
Page 74

3.9.3.2

Search

The phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the Global Phone Book:

1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press the OK button on the remote control. The system will list all entries that contain the entered letter combination. 3. It is also possible to search on first letter in the Phone Book with the letter keys on the remote control.
Page 75 of the TANDBERG Edge MXP user manual — 3.9.3.3
Page 75 · click to enlarge
Page 75

3.9.3.3

Copy Contact to My Contacts

The Copy Contact to My Contacts function is available from the Placed Calls, Missed Calls, Received Calls and Global Contacts folders, see Phone Book for details. It may be wise to copy contacts that are often used to My Contacts. Note that the local copy will not be updated if the Global Contacts are updated from the management system. How to copy a contact from the Global Phone Book to the Local Phone Book:

1. Select the contact to be copied to My Contacts. 2. Press the left arrow on the remote control, followed by the down arrow until the Copy Contact to My Contacts icon is selected. A message box telling that the operation was successful will be displayed.

General Use

Page 76 of the TANDBERG Edge MXP user manual — 3.10 Camera Control
Page 76 · click to enlarge
Page 76

3.10 Camera Control

There are several ways to control the camera:

ƒ Control the camera directly with the arrow keys when the menu is closed or use the Move Camera function in the menu to control both the near end and far end camera, see Move Camera and Far End Control for details. ƒ Use the zoom button on the remote control will zoom the picture in (+) and out (-). ƒ Use Camera Presets, see Camera Presets for details. ƒ Adjust focus, brightness and white balance, see Picture Control for details. ƒ Use Automatic Camera Tracking, see Camera Tracking for details. ƒ Use the TANDBERG Tracker, see separate instructions included with the TANDBERG Tracker.

Page 77 of the TANDBERG Edge MXP user manual — 3.10.1 Move Camera
Page 77 · click to enlarge
Page 77

3.10.1 Move Camera

It is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the Cancel button on the remote control to hide it. Use the left and right arrow keys to pan the camera, and the up and down arrow keys to tilt the camera. Use zoom + and – to zoom in and out. Moving the Camera via the menu:

1. Select the Camera Control icon from the menu. 2. Select the Move Camera button in the Camera Control menu. 3. Use the arrow keys on the remote control to pan and tilt the camera. 4. Press OK when done.

General Use

Page 78 of the TANDBERG Edge MXP user manual — 3.10.2 Far End Control
Page 78 · click to enlarge
Page 78

3.10.2 Far End Control

Far End Control allows you to control your conference partner’s camera. An example of when this feature could be especially helpful is if it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control to move the far end camera and zoom closer on the white board. Far End Camera Control is useful if e.g. it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control to move the far end camera and zoom closer on the white board. Use the left and right arrow keys to pan the camera, and the up and down arrow keys to tilt the camera. Use zoom + and – to zoom in and out. You can also control your conference partner’s video sources and presets and even request a snapshot from the far end side. Enabling Far End Control will put the system in Far End mode and camera control, camera preset, presentation, and snapshot will work on the far end camera. Far End Control only works when you are in a call and if the far end side supports H.281 (Far End Camera Control). You can prevent others from controlling your system by setting Allow Far End Camera Control to Off in Control Panel - Administrator Setting - General - Permissions, see Permissions for details. How to use Far End control:

1. Select the Camera Control icon in the menu. 2. Select the Far End Control icon. When far end camera control is selected an indicator will appear and it is possible to control the far end camera, camera preset, presentation and snapshot for the far end. 3. Deselect the Far End Control button to deactivate far end control mode. This may also be done by pressing the Cancel or the OK button. Far End Camera Presets Far End Camera Presets work just like your own camera presets. When Far End is on, use the number keys to activate far end camera presets. You are however not allowed to save far end camera presets. Far End Presentation Pressing the Presentation key or choosing a presentation from the presentation menu while Far End is on, will result in opening a far end presentation. Be aware of that the far end video sources may not correspond with the buttons in the presentation menu. If you press Document Camera, the far end side might have configured another video source on this input. Request snapshot from the Far End You can request a snapshot from the far end side. Put the system in Far End mode and press Snapshot on the remote control to take a snapshot of the current far end video (current is default snapshot source).

Page 79 of the TANDBERG Edge MXP user manual — 3.10.3 Camera Presets
Page 79 · click to enlarge
Page 79

3.10.3 Camera Presets

Use camera presets to easily vary between predefined near end camera angles. This is useful when pictures from many different camera angles have to be sent to the far end. E.g. in a meeting there is a white board, a PC and a small meeting table. Use camera presets to move between these camera perspectives in order to present the correct information to the participants at the far end without having to move the camera manually every time. A preset is deactivated when the camera is moved manually with the arrow keys. Presets are available from the menu. When you are in a call you can also activate presets directly from the remote control. You can save up to 15 presets. Each camera preset is able to store camera angle, video source and audio source selection. How to use preset directly from the remote control: When you are in a call you can activate presets with just one press on the number keys on remote control. The number keys will however not work as presets when you are in an input field, in order to write numbers or letters.

1. Press a number on the remote control. The camera will move to the corresponding angle, or video source, stored on that number. How to use presets via the menu:
1. Select Camera Control - Display Presets in the menu. 2. Select the wanted preset with the arrow keys on the remote control and press OK.

How to save a new preset directly from the remote control:

1. Move the camera to the desired position or select the desired video source that you would like to store as a preset. 2. Press a number on the remote control for 1 second to save the preset. It is possible to store one camera preset on each of the number keys, 0-9, when storing camera presets from the remote control. (Camera preset 10 is stored on the 0-key). 3. The new camera preset will overwrite any existing camera preset on that number. How to save a new Preset via the menu:

1. Move the camera to the desired position or select the desired video source that you would like to store as a preset. 2. Select Camera Control - Save New Camera Preset in the menu. 3. Enter a number between 0 and 14 and press OK. 4. Type a name for the preset to make it easier to separate the different presets. 5. Press Save. The new Camera Preset will overwrite any existing camera preset on that number.

General Use

Page 80 of the TANDBERG Edge MXP user manual — 3.10.4 TANDBERG Tracker
Page 80 · click to enlarge
Page 80

3.10.4 TANDBERG Tracker

How to save presets for the TANDBERG Tracker:

1. Select which camera preset is to be used on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select Move Camera - Save New Preset in the menu. 4. All camera presets are accessible from the TANDBERG Tracker. For more information, see separate instructions included with the TANDBERG Tracker.
Page 81 of the TANDBERG Edge MXP user manual — 3.10.5 Picture Control
Page 81 · click to enlarge
Page 81

3.10.5 Picture Control

Focus, Brightness and White balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to Picture Control in the Camera Control menu. Focus

Auto Auto focus continuously updates the focus throughout the call. When moving the camera, the system will use auto focus for 5 seconds to set the right focus of the new camera position. After 5 seconds auto focus is turned off to prevent continuous focus adjustments of the camera.

When Temporary is selected, the slide bar is enabled. Use the arrow keys to adjust the focus. The temporary focus will last until you move the camera again and auto focus will take effect.

Auto brightness continuously updates the brightness of the camera picture.

Manual When Manual is selected, the slide bar is enabled. Use the arrow keys to manually adjust the camera brightness. If brightness is set manually, the system will keep this brightness level also when the camera is moved.

Auto Auto white balance continuously updates the white balance.

Manual When Manual is selected, the “Set White balance” field is enabled. To update the white balance manually, select Manual. A white object should be held in front of the camera a few seconds before and after pressing “Set White balance”. If white balance is set manually, the system will keep this white balance also when the camera is moved.

Show 5 more labels / short text on this page
General Use · Temporary · Camera Brightness · Auto · White balance
Page 82 of the TANDBERG Edge MXP user manual — 3.10.6 Camera Tracking
Page 82 · click to enlarge
Page 82

3.10.6 Camera Tracking

Through Camera Tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at Preset 7 (Mic1), Preset 8 (Mic2) and/or Preset 9 (Mic3). How to use Camera Tracking:

1. Select the Camera Control icon in the main menu. 2. Enable Camera Tracking by choosing Camera Tracking. An indicator will appear on the screen. 3. End Camera Tracking by deselecting the Camera Tracking button. Camera Tracking will also end if you activate a camera preset or move the camera manually with the arrow keys.

Example: You have placed Microphone 1 on the table. Where should you position the camera for Preset 7? The camera position stored at Preset 7 must be related to Microphone 1. Therefore all participants who are located closest to Mic1 should be included in the Preset 7 camera position etc. When camera tracking is activated and a person close to Mic1 speaks, Preset 7 will be automatically selected.

When activating another video source (for instance document camera), camera tracking will be temporarily disabled until you re-select Main Camera or a Main Camera preset. The camera tracking speeds may be altered in the Video Settings menu in Administrator Settings, see Camera Tracking Mode for further details. A Voice Detector makes the system more tolerant of noise and ensures the camera not to move by noise such as paper shuffling, etc. Note that pressing Mic Off will temporarily disable camera tracking until you turn on the microphone again. Please also note that the camera tracking will not work properly if using an Audio Science Microphone.

Page 83 of the TANDBERG Edge MXP user manual — 3.11 Presentation
Page 83 · click to enlarge
Page 83

3.11 Presentation

The Presentation Functionality in the system enables you to show other available video sources in addition to your Main Camera. This is perfect for meetings where you would like to show a PowerPoint presentation, for example. You can even use arrow keys up and down on the remote control to activate Page Up/Down on the PC (this only applies when using VNC). Use Presentation outside a call to make a local presentation for the people in your own meeting room. Use Presentation when you are in a call to make a presentation for the far end as well. The quickest way to show a presentation is to use the Presentation Key on the remote control. The presentation key shows a predefined video source, PC is the default. It is possible to change the presentation source in the Presentation menu. Choose Presentation from the main menu if you want to select a video source manually. The Presentation Menu offers you all the available video sources supported by your system.

TANDBERG Edge MXP — 3.11 Presentation diagram (page 83)
Fig. 40 · 3.11 Presentation

General Use

Page 84 of the TANDBERG Edge MXP user manual — 3.11.1 Presentation Key
Page 84 · click to enlarge
Page 84

3.11.1 Presentation Key

The quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*). When holding the presentation key for 1 second, the presentation menu will be displayed. This menu allows you to choose other video sources. The default presentation source can be permanently changed in Presentation Settings. When using the presentation key, your presentation will be displayed as a Dual Stream, if possible. If the call does not support a dual video stream, the presentation will display as main video stream. How to start and end a Presentation using the Presentation key:

1. Press the Presentation key. The video source that is set as presentation source is displayed in full screen (PC is default). Remember to connect your PC to the codec in advance. 2. Press the Presentation key again to end the presentation and go back to main camera. * If available on your system.
Page 85 of the TANDBERG Edge MXP user manual — 3.11.2 Presentation Menu
Page 85 · click to enlarge
Page 85

3.11.2 Presentation Menu

The Presentation menu offers you all available video sources; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used as Main Video Stream or Dual Video Stream (Duo Video / H.239). Not all systems has all video sources available, see Interfaces for details. Outside a call the presentation menu only contains Main Video Sources. In a call, the headers Dual Video and Snapshot display in addition to Main Video (if the call supports Duo Video /H.239). Use the up/down keys to change between video sources and headers. Start a Dual Stream by selecting a Dual Video source. Close the Dual Stream by deselecting the video source button.

For Snapshots, see Take New Snapshot and Display Snapshot. How to change your main video source:

1. Choose the Main Video header from the Presentation menu. 2. Choose your desired video source and press OK.
TANDBERG Edge MXP — 3.11.2 Presentation Menu diagram (page 85)
Fig. 41 · 3.11.2 Presentation Menu

How to show a presentation in addition to your main video (Dual Video Stream):

1. Select the Duo Video header. 2. Choose a dual video source and press OK. 3. Deselect the active video source button to end the presentation.
TANDBERG Edge MXP — 3.11.2 Presentation Menu diagram (page 85)
Fig. 42 · 3.11.2 Presentation Menu

General Use

Page 86 of the TANDBERG Edge MXP user manual — 3.11.3 PC Presenter (DVI/VGA Input)
Page 86 · click to enlarge
Page 86

3.11.3 PC Presenter (DVI/VGA Input)

(Optional feature - not available on all systems) Users often have their presentations on a laptop that is brought into the meeting room. Remember to connect your PC to the codec before you press the Presentation button. Note that the image will appear smoother on the system if your presentation is already displaying in full screen on your PC prior to connecting your PC to the video system. Plugging a PC into the system is made extremely simple through the PC Presenter, avoiding the need for any additional hardware such as a projector, PC/Video converter or extra cables. How to connect a PC to the codec with the DVI/VGA cable:

1. Connect the VGA-DVI cable to the PC Presenter (PC DVI-I in) connector on the codec. 2. Connect the VGA-DVI cable to your PC (VGA Output). 3. If you would like to use audio as part of the presentation, connect the headset jack on your PC to the audio input on the PC presenter VGA cable. 4. When the PC is connected to the codec, hit the Presentation key to display the PC image on the system.
TANDBERG Edge MXP — 3.11.3 PC Presenter (DVI/VGA Input) diagram (page 86)
Fig. 43 · 3.11.3 PC Presenter (DVI/VGA Input)

If no PC image is displayed on your monitor, make sure that your PC is set to activate your VGA output. On most laptop PCs you must press a special key combination to switch the PC image from the PC screen to the video screen. Note that the DVI/VGA input is compliant with VESA Extended Display Identification Data (EDID) and will be able to reconfigure the PC’s screen settings if it is currently configured to a VGA format that the system doesn’t support. Also note that you can use the DVI input to transmit high resolution images from document cameras or other sources supporting the HD format 720p. For details on formats supported on 'DVI-I in', please refer to Interfaces.

Page 87 of the TANDBERG Edge MXP user manual — 3.11.4 PC Soft Presenter and VNC
Page 87 · click to enlarge
Page 87

3.11.4 PC Soft Presenter and VNC

(Optional feature) PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software must be installed on the PC. Free software can be downloaded from http://www.realvnc.com Install the software by running the downloaded file. How to configure the VNC Server software:

1. Select the following to setup VNC; Windows-Start\All Programs\Highlight RealVNC\Hightlight VNC Server\Show User Properties 2. Select Accept Socket Connections. 3. Select Auto for Display Number. Display Number in the system must then have the value 0. 4. Enter a password in the Password-field. This must correspond with the VNC Settings on your system. How to show PC using the PC Soft Presenter and VNC:

1. Start the VNC software on your PC. 2. To use VNC, you must configure VNC Settings. Open VNC Settings in the Presentation Settings menu in Administrator Settings. 3. Fill in the IP address of your PC, Display Number and Password. 4. Press Save. 5. When you now choose VNC as video source in the Presentation menu, you will see your PC using VNC. If a PowerPoint presentation is being displayed then you can scroll through the presentation by pressing the up and down arrows on the remote control. VNC settings will go back to default when the system goes to standby.

TANDBERG Edge MXP — 3.11.4 PC Soft Presenter and VNC diagram (page 87)
Fig. 44 · 3.11.4 PC Soft Presenter and VNC

General Use

Page 88 of the TANDBERG Edge MXP user manual — 3.11.5 Dual Stream (DuoVideo TF /H.239)
Page 88 · click to enlarge
Page 88

3.11.5 Dual Stream (DuoVideo TF /H.239)

(Optional feature - not available on all systems) With Dual Stream you have the opportunity to show two different live video streams simultaneously, main video and one additional source. This is handy when showing a presentation. You see the live presentation and the live video of the presenter simultaneously. When you start a presentation, Dual Stream starts automatically if both local and remote system supports Dual Stream. If one of the systems does not support Dual Stream, no second video stream will be established and your presentation will be shown as your main video. Dual Stream is available on all systems with Natural Presenter Package installed. H.239 is the new ITU standard defining how to send two video sources simultaneously.

Example: Start a meeting with main camera as video source. Press the presentation key on the remote control to start a PC presentation. PC will appear as a Dual Video Stream in addition to main camera. End the Dual Stream presentation by pressing presentation key again.

In Presentation Settings, you can set Presentation Start to Manual. That means that Dual Stream will not start automatically.

Example: Start a meeting with main camera as video source. Press the presentation key on the remote control to start a PC presentation. A dialog box appears where you can choose to show PC as Dual Video Stream or not. This is handy if you not always want to use Dual Stream.

Dual Stream and Bandwidth Using Dual Stream, the quality automatically downspeeds to the optimal bandwidth. This means that you need higher quality to allocate enough bandwidth for the two video streams. Dual Stream borrows bandwidth from main video stream. When Dual Stream is closed, the bandwidth is returned to the main video. Note that when selecting the Document Camera or PC, the system will automatically request floor when connected to a MCU conference as MultiSite host* or connected to an external MCU. * Not available on all systems.

Page 89 of the TANDBERG Edge MXP user manual — 3.11.6 Take New Snapshot
Page 89 · click to enlarge
Page 89

3.11.6 Take New Snapshot

The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use snapshot: You find Take New Snapshot in the Presentation menu.

1. Select the Snapshot header. 2. Select Take New Snapshot and press OK to take a snapshot. Snapshot is found on the Star key on the remote control.
1. Press Star and you take a snapshot of the current video source (current video is default snapshot source). You can change the snapshot source in Control Panel - Administrator Settings - Presentation Settings . Note that snapshot does not work when you are in an input field in the menu (the star key is then used to write the star sign).
TANDBERG Edge MXP — 3.11.6 Take New Snapshot diagram (page 89)
Fig. 45 · 3.11.6 Take New Snapshot

General Use

Page 90 of the TANDBERG Edge MXP user manual — 3.11.7 Display Snapshot
Page 90 · click to enlarge
Page 90

3.11.7 Display Snapshot

The system stores the last sent or received Snapshot. The snapshot is deleted automatically after the call. How to display snapshots:

1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presentation menu. 3. Press the Display Snapshot button again to deselect it. When disconnecting the call, the stored snapshot will be erased. Receiving snapshots:
1. When receiving a snapshot, the snapshot is displayed in full screen. 2. Press OK to exit from the snapshot. The last sent or received snapshot will be stored in the graphics memory and erased once the call is disconnected.
TANDBERG Edge MXP — 3.11.7 Display Snapshot diagram (page 90)
Fig. 46 · 3.11.7 Display Snapshot
Page 91 of the TANDBERG Edge MXP user manual — 3.12 Conference Services
Page 91 · click to enlarge
Page 91

3.12 Conference Services

A Multipoint Control Unit (MCU) enables several sites to participate in the same conference. During an MCU conference, the status line will provide information about the conference. You can make a multipoint conference in different ways. The Conference Services vary depending on how you make the call, see Add call for details.

TANDBERG Edge MXP — 3.12 Conference Services diagram (page 91)
Fig. 47 · 3.12 Conference Services

Example of MultiSite for high end systems. Note that the illustrations may differ from the actual product.

General Use

Page 92 of the TANDBERG Edge MXP user manual — 3.12 Conference Services
Page 92 · click to enlarge
Page 92
TANDBERG Edge MXP — 3.12 Conference Services diagram (page 92)
Fig. 48 · 3.12 Conference Services

Example of MultiSite for mid- to low end systems. Note that the illustrations may differ from the actual product. Using the system’s internal MCU, MultiSiteTF * Most TANDBERG MXP systems have an optional built-in MCU, which is called MultiSite*. It supports up to 6 video calls and 5 telephone calls including yourself for high-end systems, and 4 video calls and 3 telephone calls including yourself for the mid- and lower end systems. The MultiSite supports both Split Screen and Voice Switched mode. With MultiSite, you have the following services:

ƒ Request/Release Floor ƒ Assign Floor To Participant/Release Floor From Participant ƒ Terminal Names ƒ Layout (Auto/4 Split/5+1 Split/Voice Switched) Using an external MCU that supports Chair Control (H.243) With an external MCU that supports H.243, you have the following services:

ƒ Request/Release Floor ƒ View Participant/End View ƒ Chair Control If you take Chair control, you get the following services:

ƒ Release Chair ƒ Assign Floor To Participant/Release Floor From Participant ƒ Disconnect Participant ƒ Terminate Meeting

Page 93 of the TANDBERG Edge MXP user manual — 3.12 Conference Services
Page 93 · click to enlarge
Page 93

Using an external MCU with limited Chair Control Support you may have the following services With an external MCU that does not support H.243, you have the following services:

ƒ Request/Release Floor ƒ Terminal Names * The MultiSite option is not available on the TANDBERG 550 MXP, TANDBERG 770 MXP and TANDBERG 1000 MXP

General Use

Page 94 of the TANDBERG Edge MXP user manual — 3.12.1 Request Floor and Release Floor
Page 94 · click to enlarge
Page 94

3.12.1 Request Floor and Release Floor

When requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request Floor is useful when you want to speak or display something in front of all participants. Release Floor when you are done and make the floor available for other participants in the conference. An indicator appears when you have floor and disappears when you release floor, see floor indicator in On-screen Indicators. How to use Request and Release Floor:

1. Open the Main Menu by pressing OK. 2. Choose Conference Services and press OK. 3. Choose Request Floor and press OK. A Floor indicator will appear when you have floor. 4. When done, press the same button again, which now means Release Floor. The Floor indicator disappears.
Page 95 of the TANDBERG Edge MXP user manual — 3.12.2 Conference Layout
Page 95 · click to enlarge
Page 95

3.12.2 Conference Layout

(Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all participants on the screen simultaneously. 4 Split displays the 4 last speaking Participants including the MultiSite host. 5+1 Split displays the speaking participant in a big picture and the other participants in small pictures. Voice Switched mode displays the participant that is speaking in full screen. Switch between these picture modes using the Conference Layout menu.

TANDBERG Edge MXP — 3.12.2 Conference Layout diagram (page 95)
Fig. 49 · 3.12.2 Conference Layout

Continuous Presence layout 4 split

TANDBERG Edge MXP — 3.12.2 Conference Layout diagram (page 95)
Fig. 50 · 3.12.2 Conference Layout
TANDBERG Edge MXP — 3.12.2 Conference Layout diagram (page 95)
Fig. 51 · 3.12.2 Conference Layout

Voice Switched mode * The MultiSite option is not available on the TANDBERG 550 MXP, TANDBERG 770 MXP and TANDBERG 1000 MXP

General Use

Page 96 of the TANDBERG Edge MXP user manual — 3.12.3 Terminal Names
Page 96 · click to enlarge
Page 96

3.12.3 Terminal Names

Choose Terminal Names to see a list of the participants of the MultiSite conference. Press Cancel to go back.

Page 97 of the TANDBERG Edge MXP user manual — 3.12.4 Chair Control
Page 97 · click to enlarge
Page 97

3.12.4 Chair Control

(Not supported by TANDBERG MCU or MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Control to assume the role of chairman of the conference. Select Release Chair to end the role as chairman. A Chair indicator appears when you have Chair and disappears when chair is released.

General Use

Page 98 of the TANDBERG Edge MXP user manual — 3.12.5 Assign Floor and Release Floor from Participant
Page 98 · click to enlarge
Page 98

3.12.5 Assign Floor and Release Floor from Participant

Assign Floor allows the chairman to select which of the conference participants are to be broadcasted to all other participants.

Page 99 of the TANDBERG Edge MXP user manual — 3.12.6 View Site and End View
Page 99 · click to enlarge
Page 99

3.12.6 View Site and End View

(Not supported by TANDBERG MCU or MultiSite) View Site allows you to view any participant in the conference regardless of who has the floor and chair. Choose End View to go back to normal.

General Use

Page 100 of the TANDBERG Edge MXP user manual — 3.12.7 Disconnect Participant
Page 100 · click to enlarge
Page 100

3.12.7 Disconnect Participant

Disconnect Participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu.

Page 101 of the TANDBERG Edge MXP user manual — 3.12.8 Terminate Meeting
Page 101 · click to enlarge
Page 101

3.12.8 Terminate Meeting

Terminate Meeting allows the chairman to terminate the conference altogether. In a MultiSite call, this is equivalent to pressing End All Calls from the end call menu.

General Use

Page 102 of the TANDBERG Edge MXP user manual — 3.12.9 More about MultiSite (embedded MCU)
Page 102 · click to enlarge
Page 102

3.12.9 More about MultiSite (embedded MCU)

(Optional Feature*) Calling in to a MultiSite Any system can be part of a MultiSite conference by calling in to a MultiSite. The dial-in numbers to the MultiSite depends of the network that is used. To dial in to the MultiSite on IP:

ƒ Dial the IP Number or the IP Address of the system. All sites can dial the same number. To dial in to the MultiSite on ISDN-PRI:

ƒ Dial the ISDN number of the system. All sites can dial the same number. To dial in to the MultiSite on ISDN-BRI:

ƒ The MultiSite has specific numbers for each call that participates in the conference. To find the dial-in numbers for the MultiSite, choose Information from the main menu and open System Information from the bottom menu line. ƒ Site 2 must dial MultiSite Number 2. ƒ Site 3 must dial MultiSite Number 3. ƒ Site 4 must dial MultiSite Number 4. ƒ And so forth Receiving calls to a MultiSite When the MultiSite receives incoming calls you can accept or reject it. Pressing the green key is equivalent to pressing Accept. Pressing the red key is equivalent to pressing Reject. End a MultiSite Call Ending a MultiSite Call is not very different from ending a normal point-to-point call. Use the red key on the remote control or End Call from the main menu. The end call menu lists all the calls that participate in the conference. To end a single call, select the call, press OK or the red key on the remote control. To end all calls, press the End All Calls button in the menu. Duo Video in MultiSite calls In a MultiSite call, the MultiSite can transmit the Duo Video and/or H.239 to the other participants that support Duo Video and/or H.239. This means that any participant can send Dual Stream and the MultiSite will transmit it to the other participants. The participants that do not support Duo Video or H.239 will only receive Main Video or only the dual stream dependent on software options installed. Mix ISDN/IP A conference can consist of any combination of ISDN/IP sites. MultiSite cascading

Page 103 of the TANDBERG Edge MXP user manual — 3.12.9 More about MultiSite (embedded MCU)
Page 103 · click to enlarge
Page 103

By connecting MultiSite systems together, it is possible to connect even more sites in a cascaded MultiSite (see example below). All connections can use any combination of ISDN/IP. The host can connect up to 5 other video systems with MultiSite functionality. The cascaded systems can connect to 4 other video sites. These systems will automatically run Voice Switched mode and transmit a full screen image to the host. In this case you get 26 participants in the cascaded MultiSite conference.

TANDBERG Edge MXP — 3.12.9 More about MultiSite (embedded MCU) diagram (page 103)
Fig. 52 · 3.12.9 More about MultiSite (embedded MCU)

* The MultiSite option is not available on the TANDBERG 550 MXP, TANDBERG 770 MXP and TANDBERG 1000 MXP

General Use

Page 104 of the TANDBERG Edge MXP user manual — 3.13 Control Panel
Page 104 · click to enlarge
Page 104

3.13 Control Panel

TANDBERG Edge MXP — 3.13 Control Panel diagram (page 104)
Fig. 53 · 3.13 Control Panel

The Control Panel contains the features:

ƒ Diagnostics ƒ Text Chat ƒ Audio Demonstration ƒ Administrator Settings ƒ Restart ƒ User Guide

Page 105 of the TANDBERG Edge MXP user manual — 3.13.1 Diagnostics
Page 105 · click to enlarge
Page 105

3.13.1 Diagnostics

Diagnostics allows testing of individual system components and displays the current system settings.

TANDBERG Edge MXP — 3.13.1 Diagnostics diagram (page 105)
Fig. 54 · 3.13.1 Diagnostics

Diagnostics contain:

ƒ System Information ƒ Channel Status ƒ Call Status ƒ System Selftest ƒ View Administrator Settings ƒ IP Address Conflict Check ƒ Warnings

General Use

Page 106 of the TANDBERG Edge MXP user manual — 3.13.2 System Information
Page 106 · click to enlarge
Page 106

3.13.2 System Information

Select System Information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the System Information list. System Information contains:

System Name My ISDN Number My IP Number My IP Address MultiSite number 2 MultiSite number 3

Software Version Internal Test Software Options installed

Network Lines active Lines not active

Hardware Serial Number MAC address Ethernet Speed

Page 107 of the TANDBERG Edge MXP user manual — 3.13.3 Channel Status
Page 107 · click to enlarge
Page 107

3.13.3 Channel Status

Comprehensive information about the call progress is available through the Channel Status window. This window indicates the various stages each B-channel goes through whilst establishing a connection.

Idle Calling Connected Sync Active Releasing Released

the channel is idle when calling — the network has acknowledged the call when connection is established when the channels are synchronized when all available channels are connected waiting for the network to confirm a release of the call when disconnected - the network has acknowledged the disconnection Cause codes The most common cause codes (for ISDN) are:

1 2 16 17 18 21 28 29 31 34 41 58 65 69 81 88 100 102 127 255

Unallocated (unassigned) number No route to specified transit network (WAN) Normal clearing User busy No user responding Call rejected Invalid number format (incomplete number) Facility rejected Normal, unspecified No circuit/channel available Temporary failure Bearer capability not presently available Bearer service not implemented Requested facility not implemented Invalid call reference value Incompatible destination Invalid information element contents Recovery on timer expiry Internetworking, unspecified TANDBERG specific. undefined cause code

PRI Red Alarm Red alarm or Loss of signal (LOS) means that there is no signal and thus no framing info received (this has same effect as pulling out the PRI cable).

General Use · Status - BRI · Comments

Page 108 of the TANDBERG Edge MXP user manual — 3.13.3 Channel Status
Page 108 · click to enlarge
Page 108

PRI Yellow Alarm Yellow alarm or Remote Alarm Indicator (RAI) means that the system is receiving framing info, but in this framing info the other side tells the system that it is not reading the system’s transmitted framing info. Typically, this may be a broken connector in the TX part of the system PRI cable. This could also indicate weak or noisy signal in the TX part of the system PRI cable. PRI Blue Alarm Blue alarm means that network on the far side of the CSU is unavailable.

Example: The system is connected via a CSU (i.e. a Channel Services Unit’) as follows: System– cableA–CSU–cableB–Network If a CSU loses framing/sync from the network (example: a bad cable B), it shall no longer send valid framing out on cable A towards the system. Instead it transmits "Blue Alarm". Seen from a system receiving blue alarm, this means that the network on the far side of the CSU is unavailable.

Page 109 of the TANDBERG Edge MXP user manual — 3.13.4 Call Status
Page 109 · click to enlarge
Page 109

3.13.4 Call Status

Comprehensive information about the call is available through the Call Status window. The menu has two columns, one for transmitted and one for received audio/video/data information. If Dual Stream or MultiSite is available on your system and in use, pressing the UP/DOWN keys will show one page per connected site. Some of the information fields will vary dependent on if H.320 (ISDN calls) or H.323 (IP calls) are made.

General Use

Page 110 of the TANDBERG Edge MXP user manual — 3.13.5 System Selftest
Page 110 · click to enlarge
Page 110

3.13.5 System Selftest

The system performs a check to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active.

Page 111 of the TANDBERG Edge MXP user manual — 3.13.6 View Administrator Settings
Page 111 · click to enlarge
Page 111

3.13.6 View Administrator Settings

This window displays all the system settings. Use the arrow key on the remote control to scroll through the list. View Administrator Settings may contain*:

General Settings System Name Language Dual Monitor Auto answer Max Call Length Access Code Incoming MCU calls Incoming Telephone calls Far End Control Fallback to Telephony

TV Monitor Format Picture Layout VGA Monitor Format VGA Out Quality PC Picture Format Allow VGA 50Hz

Software Options Options Installed Serial Number Current Option Key

Menu Timeout in Call Welcome Menu Welcome Picture Logo Balloon Help Display Welcome Text Welcome Text Administrator Password

Duo Video Mode Start up Video Source Presentation Source Snapshot Source Auto Display Snapshot PIP Appearance PIP Placing

Address Display Number Call Quality Video Algorithm Audio Algorithm Interlaced

Video Quality Main Camera

Show 5 more labels / short text on this page
General Use · Screen Settings · Menu Settings · Presentation Settings · VNC Settings
Page 112 of the TANDBERG Edge MXP user manual — 3.13.6 View Administrator Settings
Page 112 · click to enlarge
Page 112
TANDBERG Edge MXP — 3.13.6 View Administrator Settings diagram (page 112)
Fig. 55 · 3.13.6 View Administrator Settings

Call Type Network Bandwidth Restrict (56k) Auto H320 Bandwidth Auto H323 Bandwidth SIP

Mic1 Mic2 Mic3 Audio4 Audio5 Audio6 Mix Mode VCR Ducking

Audio Leveling (AGC) Mics Audio5 (AUX) Audio6 (VCR) Received Audio

Alert Tones & Volume Video Call Alert Tone Telephone Alert Tone Alert Volume Alert Speaker Key Tones

Camera Tracking Mode MCU Status Line Web Snapshot MultiSite Picture Mode

Page 113 of the TANDBERG Edge MXP user manual — 3.13.6 View Administrator Settings
Page 113 · click to enlarge
Page 113

Video Name Main Cam AUX Doc Cam VCR PC VGA VNC

Network Type ISDN-BRI\PRI\Leased E1\T1\Enternal H331 ISDN Switch Type ETSI (Euro ISDN),… Line1 Setup On Number1 Number2 SPID1 SPID2 Line2 Setup On Number1 Number2 SPID1 SPID2 Line3 Setup On Number1 Number2 SPID1 SPID2

Advanced ISDN Settings Sub Address Validate Numbers (MSN) Parallel Dial Send Own Numbers Sending Complete

Number Range ISDN-PRI Switch Type

Max Channels Low Channel High Channel Search High, Low Line Settings: T1 Cable Length 1 T2 Cable Length 2 E1 CRC-4

Advanced ISDN PRI Settings NSF Code Video NSF Code Telephone Call

Call Control Network Interface Max Channels Start Channels T1 Line Coding Line Settings

Call Control RS66 RS449/V.35 Compatible

IP Settings IP assignment

Show 6 more labels / short text on this page
General Use · White balance Brightness · ISDN-PRI Settings · Channel Hunting · Leased E1/T1 Settings · External network configuration
Page 114 of the TANDBERG Edge MXP user manual — 3.13.6 View Administrator Settings
Page 114 · click to enlarge
Page 114
TANDBERG Edge MXP — 3.13.6 View Administrator Settings diagram (page 114)
Fig. 56 · 3.13.6 View Administrator Settings

H.323 Settings E.164 Alias Use Gatekeeper Gatekeeper IP H.323 Prefix

IP Precedence Audio Video Data Signaling IP Type of Service (TOS)

SNMP Settings SNMP Trap Host1 SNMP Trap Host2 SNMP Trap Host3 SNMP Community

Streaming Settings Address Address Port TTL/Router Hops Streaming Source Allow Remote Start Announcements Video rate (kbps)

Auto H.320 H.323 Network Profile 4 Network Profile 5 Network Profile 6

Data Port 2 Baud rate Parity Databits Stopbits Mode

* The administrator settings available will vary within the MXP system range depending on system and what software options installed.

Page 115 of the TANDBERG Edge MXP user manual — 3.13.7 IP Address Conflict Check
Page 115 · click to enlarge
Page 115

3.13.7 IP Address Conflict Check

The system will give a warning if there is an IP conflict. The user may initiate this check by selecting IP Address Conflict Check.

General Use

Page 116 of the TANDBERG Edge MXP user manual — 3.13.8 Warnings
Page 116 · click to enlarge
Page 116

3.13.8 Warnings

Any warnings registered by the system will be displayed in the Warnings menu. Open a warning in the list to get more information about the warning.

TANDBERG Edge MXP — 3.13.8 Warnings diagram (page 116)
Fig. 57 · 3.13.8 Warnings

The following warnings may be displayed if detected by the system, depending on system type and configuration: ISDN BRI warnings

ƒ ISDN is enabled on BRI line x, but the line is not connected. Please check your network connection or disable the line. (101) ƒ There is something wrong with ISDN BRI line x. Please check your network connection. (102) IP network quality warnings

ƒ The system is experiencing, equal to or more than 5%, packet loss in the IP network. This may affect the quality of the call. ƒ The system is experiencing high jitter, equal to or more than 200 ms, in the IP network. This may affect the quality of the call. ƒ The system is dropping IP packets due to latency in the network. This may affect the quality of the call. ISDN PRI warnings

ƒ ISDN PRI is configured for this system, but the line is not connected. Please check your network connection or disable the network. (131) ƒ There is something wrong with the ISDN PRI line (Blue alarm). Please check your network connection. (132) ƒ There is something wrong with the ISDN PRI line (Yellow alarm). Please check your network connection. (133) ƒ There is something wrong with the ISDN PRI line (D-Channel not active). Please check your network connection. (134) External Network warnings

ƒ External Network is configured for this system, but the line is not connected. Please check your network connection or disable the network. (161) Leased E1/T1 warnings

ƒ Leased E1/T1 is configured for this system, but the line is not connected. Please check your network connection or disable the network. (191) ƒ There is something wrong with the Leased E1/T1 line (Blue alarm). Please check your network connection. (192)

Page 117 of the TANDBERG Edge MXP user manual — 3.13.8 Warnings
Page 117 · click to enlarge
Page 117

ƒ There is something wrong with the Leased E1/T1 line (Yellow alarm). Please check your network connection. (193) H323 gatekeeper warnings

ƒ Could not register to the gatekeeper. ƒ The gatekeeper rejected to register the system. Another system is already registered with the same alias or H.323 ID. ƒ The max capacity on the gatekeeper is reached. Registration failed. ƒ Tried to register to the gatekeeper without a valid alias. Registration failed. ƒ The system is not allowed to register with this gatekeeper. ƒ Can not find the gatekeeper. Check the gatekeeper configurations on the system.

General Use

Page 118 of the TANDBERG Edge MXP user manual — 3.13.9 Text Chat
Page 118 · click to enlarge
Page 118

3.13.9 Text Chat

While in an ISDN or IP call to another system supporting Text Chat (T.140), select Text Chat from the Control Panel. Enter text in the displayed window. How to use Text Chat:

1. Choose Text Chat from the Control Panel to open the Text Chat window. 2. Enter text with the number keys like on a mobile phone. The text is sent to the far end continuously letter by letter. 3. Press OK to end Text Chat and escape from the text chat window.
Page 119 of the TANDBERG Edge MXP user manual — 3.13.10 Audio Demo
Page 119 · click to enlarge
Page 119

3.13.10 Audio Demo

General Use

Page 120 of the TANDBERG Edge MXP user manual — 3.13.11 Administrator Settings
Page 120 · click to enlarge
Page 120

3.13.11 Administrator Settings

Administrator Settings contains the configuration of the whole system. It is recommended to password protect Administrator Settings to prevent occasional users from making changes to the system. See Administrator Settings for further details.

Page 121 of the TANDBERG Edge MXP user manual — 3.13.12 Restart
Page 121 · click to enlarge
Page 121

3.13.12 Restart

Restart the system by pressing the Restart button. You are prompted with a dialog box saying: Do you want to restart the system? Press OK to restart, press Cancel (X) to abort.

TANDBERG Edge MXP — 3.13.12 Restart diagram (page 121)
Fig. 58 · 3.13.12 Restart

General Use

Page 122 of the TANDBERG Edge MXP user manual — 3.13.13 User Guide
Page 122 · click to enlarge
Page 122

3.13.13 User Guide

The on screen user guide takes you through a quick step-by-step introduction to videoconferencing. It gives the user basic skills in how to use the system.

TANDBERG Edge MXP — 3.13.13 User Guide diagram (page 122)
Fig. 59 · 3.13.13 User Guide
Page 123 of the TANDBERG Edge MXP user manual — 4 Administrator Settings
Page 123 · click to enlarge
Page 123

4 Administrator Settings

TANDBERG Edge MXP — 4 Administrator Settings diagram (page 123)
Fig. 60 · 4 Administrator Settings

Administrator Settings contain all the settings of the system. Making changes to Administrator Settings will change the behavior of the system. It is recommended to password protect the access to Administrator Settings to prevent occasional users from making crucial changes to the system, see Administrator Password. Administrator Settings contain:

ƒ General ƒ Menu Settings ƒ Presentation Settings ƒ Call Quality ƒ Audio ƒ Video ƒ Security ƒ Network ƒ Restore Default Settings

Page 124 of the TANDBERG Edge MXP user manual — 4.1 General Settings
Page 124 · click to enlarge
Page 124

4.1 General Settings

When installing the system, go through the General Settings menu to ensure that you have the right settings for your system, see System Configuration.

General Settings contain:

ƒ Language ƒ System Name / International Name* ƒ Auto Answer ƒ Phone Book Settings ƒ External Service Settings ƒ Permissions ƒ Screen Settings ƒ Software Options ƒ Date and Time Settings * This field is only visible if the system name contains Asian and non-Latin character text input.

Page 125 of the TANDBERG Edge MXP user manual — 4.1.1 Language
Page 125 · click to enlarge
Page 125

4.1.1 Language

The system supports 16 different languages for its on-screen menus; English, German, French, Norwegian, Swedish, Italian, Spanish, Portuguese, Russian, Finnish, Chinese Simplified, Chinese Traditional, Japanese, Korean, Thai and Arabic. Select the preferred language and press OK to save. Note that pressing the Phone Book button 5 times followed by the number button 1 on the remote control will reset the menu language to English.

Administrator Settings

Page 126 of the TANDBERG Edge MXP user manual — 4.1.2 System Name
Page 126 · click to enlarge
Page 126

4.1.2 System Name

System Name identifies the system:

ƒ On the welcome page. ƒ During an MCU conference call. ƒ When using the Web-interface. ƒ When the codec is acting as an SNMP Agent. ƒ Towards a DHCP server. ƒ H323 ID. Other systems can call in using this name instead of IP-number/IP-address. System Name is blank by default. System name can be alphanumeric and up to 50 characters long. Follow the installation procedure to enter a System Name.

Page 127 of the TANDBERG Edge MXP user manual — 4.1.3 International Name
Page 127 · click to enlarge
Page 127

4.1.3 International Name

If the System Name contains Asian and non-Latin character text input, the International Name using Latin characters only, must be specified as well. This is in order to make other systems understand the system name.

Administrator Settings

Page 128 of the TANDBERG Edge MXP user manual — 4.1.4 Auto Answer
Page 128 · click to enlarge
Page 128

4.1.4 Auto Answer

The auto answer setting decides whether an incoming call is put through automatically or manually.

On The system will automatically answer all incoming calls.

The system will automatically answer all incoming calls and switch the microphone off when the call is connected. Press Mic Off to switch the microphone on.

Off You must manually answer all incoming calls by pressing OK or the Call key.

On+Mic Off

Page 129 of the TANDBERG Edge MXP user manual — 4.1.5 Phone Book Settings
Page 129 · click to enlarge
Page 129

4.1.5 Phone Book Settings

On The Corporate Directory is available in the menu.

Off The Corporate Directory is hidden from the menu and is unavailable for users.

IP address Enter the IP address of the management system that provides the Phone Book. Path The Path indicates the function of the management system.

Administrator Settings · Corporate Directory

Page 130 of the TANDBERG Edge MXP user manual — 4.1.6 External Services Settings
Page 130 · click to enlarge
Page 130

4.1.6 External Services Settings

On When set to On External Services are available.

Off When set to Off External Services are unavailable.

IP address Enter the IP address of the service provider for External Services. Path Enter the Path to the External Services provider. The services available are defined by the service provider.

External Services

Page 131 of the TANDBERG Edge MXP user manual — 4.1.7 Permissions
Page 131 · click to enlarge
Page 131

4.1.7 Permissions

Permissions contains settings for incoming MCU Calls, incoming telephone Calls, Far End Control, Remote Software Upgrade and Fallback to Telephony. Access Code An access code will help you control the use of the system. All users must enter a code to identify themselves and the call will be charged on their account. Access Codes are handy for group systems where there are more users or divisions that share the costs of using the system. Access Code can be set to "On" and "Off". Please refer to section Appendix 5 for more information on Access codes.

On When making a call, an Access Code dialog box will be shown. The user must enter the correct password in order to put the call through.

Off No password is necessary to make a call.

On When you are in a call, the system will provide visual and audible indications of an incoming call and ask you to accept/reject the call.

Off The system will not accept incoming calls when you are in a call.

On The system will accept incoming telephone calls.

Off The system will not accept incoming telephone calls. This is useful to prevent incoming calls from systems other than videoconferencing systems.

Administrator Settings · Incoming MCU Calls · Incoming Telephone Calls

Page 132 of the TANDBERG Edge MXP user manual — 4.1.7 Permissions
Page 132 · click to enlarge
Page 132

Far End Camera Control

On The far end will be able to:

  • Control your camera
  • Select your video sources
  • Activate your camera presets
  • Request snapshots

Off The far end can access none of the four features above on the local system. You will however still be able to control the camera on the far end.

Fallback to Telephony When dialing a number and the system fails to place a video call to the number dialed, the system will attempt to place a telephone call if Fallback to Telephony is enabled.

On Enables fallback from video calls to telephone calls.

Off Disables fallback.

Far End ISDN System Upgrade It is possible to upgrade software remotely, i.e. a far end system may upgrade software on a local system via http on ISDN. The system to be upgraded must be configured to allow remote software upgrade. It is possible to set a password which is needed for the far end system to be able to accomplish the software upgrade.

On The system will allow a remote system to upgrade local software.

Off The system will not allow a remote system to upgrade local software.

Page 133 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 133 · click to enlarge
Page 133

4.1.8 Screen Settings

If Auto Layout is On the system will change layouts automatically depending on the number of participants in a call and if you have a dual video stream or not. Please refer to Layout for more information.

If Auto Layout is Off there will be no automatic layout changes during a call. All desired layout changes must be done manually.

Use Screen as Local PC Monitor Use the Selfview button to switch from local PC display to standard conference layout.

On If Local PC Display is On you will be able to have Local PC displayed both outside a call and in a call.

If Local PC Display is Off you will not be able to see a Local PC image.

On Selfview, snapshots and Dual Stream will be displayed on the second monitor.

Off The second monitor shows selfview only.

Show 5 more labels / short text on this page
Administrator Settings · Auto Layout · On · Off · Off
Page 134 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 134 · click to enlarge
Page 134

Picture Layout The Advanced Picture Layout is related to the Layout button on the remote control and it can be used at any time to change the screen layout. For wide screen systems POP mode is recommended. You will get optimized picture layouts for wide screen by pressing the Layout button on the remote.

Picture in Picture (PIP)

Pressing the Layout button on the remote will result in an extra picture in smaller view (Picture in Picture). Press the Layout button to move it around in the corners of the screen and finally hide it. Pressing and holding Layout for 1 second will hide the small picture directly from any position.

Picture outside Picture (POP)

Press the Layout button to see the images side-by-side, e.g. 1+1 layout, where the far end and near end are displayed as images of equal size, see figure below. Press the Layout button once more to change to 1+2 layout. The far end image will be displayed as the main video, with the near end, usually the user of the system, as a smaller image in the upper right corner. If Duo Stream is used, the Dual Stream image is displayed as the main image and the far end and near end as smaller images to the right, see figure below for an example. Press the Layout button again to get the 1+3 layout. The next time the Layout button is pressed, the normal full screen view of the far end is displayed. Pressing and holding Layout for 1 second will always bring you back to full screen.

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 134)
Fig. 61 · 4.1.8 Screen Settings

Example of Picture in Picture.

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 134)
Fig. 62 · 4.1.8 Screen Settings

Example of 1+1 Side-by-Side view (wide screen).

Page 135 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 135 · click to enlarge
Page 135
TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 135)
Fig. 63 · 4.1.8 Screen Settings

Example of 1+2 Picture outside Picture (wide screen).

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 135)
Fig. 64 · 4.1.8 Screen Settings

Example of 1+3 Picture outside Picture (wide screen). Note that if both TV monitor format and VGA format is set to Normal, the system will skip the 1+3 layout, which is not beneficial for 4:3 monitors.

Administrator Settings

Page 136 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 136 · click to enlarge
Page 136

VGA Monitor Format To fully leverage your wide screen display, activate the Native 16:9 format by setting the VGA Monitor Format to Wide. Note that you should only change this setting if your VGA monitor is a wide screen (16:9) monitor or projector. The VGA and DVI output will then be optimized for Wide Screen VGA and High Definition (HD) display.

Normal Output format is optimized for Normal VGA monitors (4:3)

Wide Output format is optimized for Wide VGA monitors (16:9)

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 136)
Fig. 65 · 4.1.8 Screen Settings

Wide screen VGA or TV monitor in Normal (stretched) mode.

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 136)
Fig. 66 · 4.1.8 Screen Settings

Wide screen VGA or TV monitor In Wide (native) mode. VGA Out Quality* The supported range of VGA formats will be optimized for the VGA display monitor based on the source image. VGA Out Quality enables the user to change the preferred format for the DVI/VGA output. It is recommended to keep this setting in Auto unless your screen doesn’t support some of the XGA or SVGA formats the system is using. Note that the VGA Out port support VESA Power Management.

Page 137 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 137 · click to enlarge
Page 137

Auto VGA output format will be optimized dependant of the video source format, refresh and of the EDID information available. Supported formats are: SVGA (800x600) 75Hz XGA (1024x768) 60Hz / 75Hz WXGA (1280x768) 60Hz

SVGA 800x600 75Hz VGA output format is forced to SVGA format (800x600) 75Hz

XGA 1024x768 60Hz VGA output format is forced to XGA format (1024x768) 60Hz

VGA Out Quality for Wide XGA: If VGA Monitor Format is set to Wide, PC Picture Format is set to Normal, VGA Out Quality is set to Auto, the layout on the monitor is either full screen or POP, and the input source to the largest window is PC with resolution 1024x768, the system will use WideXGA (1280x768) instead of XGA, when the monitor supports this.

PC Picture Format (wide screen monitors only) PC Picture Format setting only takes effect when TV or VGA Monitor Format is set to Wide. Use this setting to determine if you want your PC presentations to be shown stretched in full screen, or with correct aspect ratio using part of the widescreen display. With the VGA Out Quality set to Auto the presentation will be of the best possible quality supported by the monitor.

Normal VGA output will have 4:3 aspect ratios on wide screen monitor.

VGA output will utilize the wide screen monitor at full.

TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 137)
Fig. 67 · 4.1.8 Screen Settings

PC presentation shown in Normal (correct ratio) mode.

Administrator Settings · Wide

Page 138 of the TANDBERG Edge MXP user manual — 4.1.8 Screen Settings
Page 138 · click to enlarge
Page 138
TANDBERG Edge MXP — 4.1.8 Screen Settings diagram (page 138)
Fig. 68 · 4.1.8 Screen Settings

PC Presentation shown in Wide (stretched) mode.

Page 139 of the TANDBERG Edge MXP user manual — 4.1.9 Software Options
Page 139 · click to enlarge
Page 139

4.1.9 Software Options

The system requires a valid option key to activate MultiSite and/or Presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key. A restart of the system is required after entering a new option and/or bandwidth keys. If the key is invalid, the original key will be used. The following options are available:

1. No option 2. Presenter 3. MultiSite + Presenter 4. Bandwidth options

Administrator Settings

Page 140 of the TANDBERG Edge MXP user manual — 4.1.10 Date and Time Settings
Page 140 · click to enlarge
Page 140

4.1.10 Date and Time Settings

NTP IP This is the NTP time server address from which the system can get updated time information. See IP Services for more details.

The NTP IP address is set automatically.

The NTP IP address is set manually.

IP Address The IP Address for obtaining the date and time information. Time Zone Select the correct time zone for the location of your system. Date Format Choose between DD/MM/YY, MM/DD/YY, or YY/MM/DD as the desired date format. Time Format Select 12h or 24h time format. Daylight Savings

Automatically adjust for daylight savings changes.

Do not adjust for daylight saving changes.

Show 4 more labels / short text on this page
Auto · Manual · On · Off
Page 141 of the TANDBERG Edge MXP user manual — 4.2 Menu Settings
Page 141 · click to enlarge
Page 141

4.2 Menu Settings

TANDBERG Edge MXP — 4.2 Menu Settings diagram (page 141)
Fig. 69 · 4.2 Menu Settings

Menu Settings contain the settings:

ƒ Input Editor Language ƒ Menu Timeout In Call ƒ Menu on TV ƒ Menu on PC ƒ Balloon Help ƒ Administrator Password ƒ Kiosk Mode Settings ƒ Startup ƒ Icons

Administrator Settings

Page 142 of the TANDBERG Edge MXP user manual — 4.2.1 Input Editor Language
Page 142 · click to enlarge
Page 142

4.2.1 Input Editor Language

When the Input Editor Language is set to Chinese, Korean or Japanese the user will be able to enter Chinese / Korean / Japanese characters into an input field like the System Name or Phone Book, using the remote control.

Page 143 of the TANDBERG Edge MXP user manual — 4.2.2 Menu Timeout in Call
Page 143 · click to enlarge
Page 143

4.2.2 Menu Timeout in Call

The Main menu appears on the bottom line of the screen. Set Menu Timeout In Call to On if you want the menu to time out automatically when you are in a call.

On The menus will time out automatically after 15 seconds if there is no activity on the remote control. Menu timeout does only apply when you are in a call. Outside a call, the menu will not time out.

Off The menu will not time out automatically. Press Cancel (X) to hide the main menu manually.

Administrator Settings

Page 144 of the TANDBERG Edge MXP user manual — 4.2.3 Menu on TV
Page 144 · click to enlarge
Page 144

4.2.3 Menu on TV

The Menu on TV setting decides if the menu shall be displayed on the TV screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa.

On The menu is available on the TV screen.

Off The menu is not available on the TV screen.

Page 145 of the TANDBERG Edge MXP user manual — 4.2.4 Menu on PC
Page 145 · click to enlarge
Page 145

4.2.4 Menu on PC

The Menu on PC setting decides if the menu shall be displayed on the PC (VGA screen) screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa.

On The menu is available on the PC screen.

Off The menu is not available on the PC screen.

Administrator Settings

Page 146 of the TANDBERG Edge MXP user manual — 4.2.5 Balloon Help
Page 146 · click to enlarge
Page 146

4.2.5 Balloon Help

It is possible to enable / disable the balloon help window.

On Choose On if you want help text windows to appear.

Off There will be no help text window.

Page 147 of the TANDBERG Edge MXP user manual — 4.2.6 Administrator Password
Page 147 · click to enlarge
Page 147

4.2.6 Administrator Password

It is recommended to put an Administrator Password on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password dialog box will pop up when you choose Administrator Settings from the Control Panel. This will prevent occasional users from going in to administrator settings. With an administrator password, you can ensure that your system will behave in the same way every time and that only approved people are allowed to make changes to the system.

Administrator Settings

Page 148 of the TANDBERG Edge MXP user manual — 4.2.7 Kiosk Mode Settings
Page 148 · click to enlarge
Page 148

4.2.7 Kiosk Mode Settings

Kiosk Mode In Kiosk Mode the system is set to a simplified state where it can be controlled with just the four arrow keys and OK. You will get a simplified on-screen menu with only basic functionality available:

ƒ make calls (using predefined contacts in the phone book) ƒ receive calls ƒ end calls ƒ adjust volume

Using Kiosk Mode Outside a call the Welcome Menu will be displayed:

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 148)
Fig. 70 · 4.2.7 Kiosk Mode Settings

Place a Call, Volume and Close.

Page 149 of the TANDBERG Edge MXP user manual — 4.2.7 Kiosk Mode Settings
Page 149 · click to enlarge
Page 149

If Language Menu is enabled you will first see the language selection menu. Select language and the Welcome Menu will be displayed with your desired language. In a call, the system will display Far End video in full screen. If Max Call Length is set to a value and the system is in a call, the system will display a warning when it is 5 minutes, 1 minute and 10 seconds left of the call. If pressing OK when the system is in a call, the following menu will be displayed: End Call, Volume and Close. The following Kiosk Mode Settings allow you to make some adjustments to the system's behavior in Kiosk Mode. Kiosk Mode - Language Menu

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 149)
Fig. 71 · 4.2.7 Kiosk Mode Settings

On When On the system will display the language menu as the first menu in kiosk mode.

Off When Off the system will display the welcome menu in English (default).

Kiosk Mode - Available Languages In Kiosk Mode the system supports 7 different languages for its simplified on-screen menu; English, German, French, Norwegian, Swedish, Italian and Spanish. Select the preferred language.

Administrator Settings

Page 150 of the TANDBERG Edge MXP user manual — 4.2.7 Kiosk Mode Settings
Page 150 · click to enlarge
Page 150

Kiosk Mode - Auto Dial*

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 150)
Fig. 72 · 4.2.7 Kiosk Mode Settings

On The system will automatically dial to the first contact in the Phone Book when he handset is lifted. If this contact is busy, the system will call the second number in the Phone Book and so on. If the user places the handset in the cradle, the system will switch to Speaker Mode. Only the Far End system can end the call.

Off The system will not make a call automatically when the handset is lifted.

* Applies only to systems with handset Kiosk Mode - Allow Use of Remote Control

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 150)
Fig. 73 · 4.2.7 Kiosk Mode Settings

Yes All keys on the remote control are enabled.

No All keys except the arrow keys and OK key are disabled.

Kiosk Mode - Phone Book

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 150)
Fig. 74 · 4.2.7 Kiosk Mode Settings

Local The system will use the Local Phone Book in Kiosk Mode.

Corporate The system will use the Corporate Directory in Kiosk Mode.

Kiosk Mode - Kiosk Menu

TANDBERG Edge MXP — 4.2.7 Kiosk Mode Settings diagram (page 150)
Fig. 75 · 4.2.7 Kiosk Mode Settings

On The Kiosk Mode menus will appear on the screen.

Off No menus or indicators will appear on the screen.

Page 151 of the TANDBERG Edge MXP user manual — 4.2.8 Startup
Page 151 · click to enlarge
Page 151

4.2.8 Startup

Welcome Menu The Welcome Menu contains the Main Menu, System Status, your System Name and dial in numbers.

On The Welcome Menu is shown when the system wakes up from standby mode.

Off The Welcome Menu is not shown when the system wakes up from standby mode. Press the OK button to open the welcome menu.

Welcome Picture The Welcome Picture is what you see in the background of the welcome menu.

Selfview Selfview is shown in the background of the welcome menu. In most cases this means that main camera is displayed and you can see the video image of yourself.

Off No picture is shown in the background of the welcome menu.

Logo It is possible to upload a company logo to the system. For more information about how to upload a Logo, see Appendix 6. Set the Logo settings to On to display the logo.

On Choose On if you want the company logo to appear in the background of the welcome menu.

Off The logo is not displayed.

Display Welcome Text The welcome text displays your system name and dial in numbers by default. It is possible to hide this information by choosing Display Welcome Text Off.

Administrator Settings

Page 152 of the TANDBERG Edge MXP user manual — 4.2.8 Startup
Page 152 · click to enlarge
Page 152

On Welcome text is displayed on the welcome menu.

Off Welcome text is not displayed on the welcome menu.

Welcome Text You can change the welcome text to any text you like, instead of the default text. Remember that Display Welcome Text must be On to be able to edit the welcome text.

Page 153 of the TANDBERG Edge MXP user manual — 4.2.9 Icons
Page 153 · click to enlarge
Page 153

4.2.9 Icons

The following indicator icons may be set to on or off:

ƒ Mic Off ƒ Volume Off ƒ On Air ƒ Encryption ƒ Bad Network ƒ Telephone See On-screen Indicators for details.

Administrator Settings

Page 154 of the TANDBERG Edge MXP user manual — 4.3 Presentation Settings
Page 154 · click to enlarge
Page 154

4.3 Presentation Settings

TANDBERG Edge MXP — 4.3 Presentation Settings diagram (page 154)
Fig. 76 · 4.3 Presentation Settings

Presentation Settings contain:

ƒ Presentation Start ƒ H.239 ƒ Startup Video Source ƒ Presentation Source ƒ Snapshot Source ƒ Auto-Display Snapshot ƒ PIP Appearance ƒ PIP Placing ƒ VNC Settings

Page 155 of the TANDBERG Edge MXP user manual — 4.3.1 Presentation Start
Page 155 · click to enlarge
Page 155

4.3.1 Presentation Start

If your system has Dual Stream capabilities, you can show two video streams at the same time (see also Dual Stream). Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when starting a presentation. Dual Stream requires the Presenter Option and H.263 video. To check which options are installed, see the System Information menu in Control Panel. Manual means that you manually choose if you want to start Duo Video or not every time you start a presentation.

Dual Stream starts automatically when you start a presentation (in other words, when you choose a second video source). If your system or the far end system is not capable of Duo Video/H.239, you will not use Dual Stream, but rather send the presentation source as your Main Video

When starting a presentation, select Presentation in the call menu and select Start Presentation. Choose a video source from the list displayed on the screen.

Administrator Settings · Auto · Manual

Page 156 of the TANDBERG Edge MXP user manual — 4.3.2 H.239
Page 156 · click to enlarge
Page 156

4.3.2 H.239

H.239 supports transmission of two video streams. It combines elements of Duo Video and People+Content. If H.239 is disabled you will still be able to start TANDBERG Dual Video Stream*

Enabled Enables H.239

Disabled Disables H.239

* The TANDBERG 550 MXP can only receive Dual Video Stream.

Page 157 of the TANDBERG Edge MXP user manual — 4.3.3 Startup Video Source
Page 157 · click to enlarge
Page 157

4.3.3 Startup Video Source

The Startup Video Source is the video source on display when the system wakes up from standby mode. If you use Main Camera as start up source, the system will start with Main Camera every time the system wakes up from standby, regardless of what the previous user was using. You can change Startup Video Source to Main Camera, PC, Document Camera, VCR, AUX, VNC or Current depending on what video sources you have available for your system. Choosing Current will result in the last used video source before the system went to standby.

Administrator Settings

Page 158 of the TANDBERG Edge MXP user manual — 4.3.4 Presentation Source
Page 158 · click to enlarge
Page 158

4.3.4 Presentation Source

The Presentation Source is connected to the Presentation button on the remote. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. You can change the Presentation Source to any video source and none. Choosing none results in opening the Presentation menu when pressing the Presentation key. * Only for systems with the PC video input available.

Page 159 of the TANDBERG Edge MXP user manual — 4.3.5 Snapshot Source
Page 159 · click to enlarge
Page 159

4.3.5 Snapshot Source

When you take a Snapshot, you get a snapshot of the Snapshot Source. Current is the default Snapshot Source. This means that you take a snapshot of the video source that is currently active. You can change the Snapshot Source to any video source. In this way you can program the snapshot key to apply only for PC for instance. Press Snapshot and you will take a PC snapshot regardless of what video source that is currently active.

Administrator Settings

Page 160 of the TANDBERG Edge MXP user manual — 4.3.6 Auto-Display Snapshot
Page 160 · click to enlarge
Page 160

4.3.6 Auto-Display Snapshot

Select Auto to automatically display a received snapshot. Turn Auto-Display Snapshot Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Auto-Display Snapshot set for Manual, you must enter the Presentation menu to display a snapshot.

Auto A sent or received snapshot will automatically be displayed on the screen.

Manual A sent or received snapshot will not be displayed on the screen. To see the snapshot, choose Display Snapshot in the Presentation menu.

Page 161 of the TANDBERG Edge MXP user manual — 4.3.7 PIP Appearance
Page 161 · click to enlarge
Page 161

4.3.7 PIP Appearance

A Picture in Picture (PIP) is a smaller picture placed in one of the corners of the screen. The PIP enables you to see an extra picture in your video conference.

Auto PIP Auto means that Picture In Picture will appear automatically when it is suitable. A picture in picture is nice when you use Duo Video and you need an extra window to see all the pictures. You can of course show or hide the PIP with the Layout button on the remote anytime.

On PIP On means that a Picture in Picture will always be displayed.

Off PIP Off means that PIP is not displayed automatically.

Administrator Settings

Page 162 of the TANDBERG Edge MXP user manual — 4.3.8 PIP Placing
Page 162 · click to enlarge
Page 162

4.3.8 PIP Placing

PIP Placing lets you decide where the PIP shall appear. You can of course move the PIP with the Layout button on the remote anytime.

Top Right PIP is placed in the Top Right corner.

PIP is placed in the Bottom Right corner.

PIP is placed in the Bottom Left corner.

Top Left PIP is placed in the Top Left corner.

Bottom Right · Bottom Left

Page 163 of the TANDBERG Edge MXP user manual — 4.3.9 VNC Settings
Page 163 · click to enlarge
Page 163

4.3.9 VNC Settings

VNC Settings is necessary when using a VNC presentation. See chapter PC Soft Presenter and VNC for more information on how to use VNC.

Address The IP-address of the PC with the VNC software installed. To find the IP- address of the PC, place the mouse pointer on the VNC program icon in the lower right corner of the Windows taskbar. You can also select Command Prompt from the Startup-menu\Run and type cmd then enter. This will open a command window and from here. Type “ipconfig” and press enter.

The display number for VNC is 0 and upwards. If you are using WinVNC, double-click on the icon on the taskbar to view WinVNC properties. This number should correspond with Display Number in this menu.

Enter the same password as specified in WinVNC properties. The password will be shown as asterisk signs (*) the next time you enter the menu.

Administrator Settings · Display Number · Password

Page 164 of the TANDBERG Edge MXP user manual — 4.4 Call Quality
Page 164 · click to enlarge
Page 164

4.4 Call Quality

TANDBERG Edge MXP — 4.4 Call Quality diagram (page 164)
Fig. 77 · 4.4 Call Quality

Call Quality contains the settings:

ƒ Video Algorithm ƒ Audio Algorithm ƒ AAC-LD 128kbps ƒ Natural Video ƒ Max Upstream Rate ƒ Video Quality ƒ Default Call Settings

Page 165 of the TANDBERG Edge MXP user manual — H.261
Page 165 · click to enlarge
Page 165

4.4.1 Video Algorithm

The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems.

H.264 Bandwidth efficient video compression and decompression.

H.263

Normal video compression and decompression.

H.261

Legacy video compression and decompression. The system will always have H.261 enabled. Therefore it is impossible to uncheck H.261.

Administrator Settings

Page 166 of the TANDBERG Edge MXP user manual — AACLD
Page 166 · click to enlarge
Page 166

4.4.2 Audio Algorithm

The system will automatically select the best audio algorithm based on the call rate and the capabilities of the remote system. Use this menu to disable audio algorithms in case you want to remove “low quality” audio, or if you have interoperability issues calling other systems.

G.722 High quality audio (7 kHz at 48kbps, 56kbps or 64kbps)

G.728 Compressed normal quality audio (telephone quality, 3.1 kHz at 16kbps)

G.711 Normal quality audio (telephone quality 3.1kHz at 64kbps). This audio algorithm is mandatory for video conferencing equipment and is impossible to uncheck.

G.722.1 Compressed high quality audio (7 kHz at 24kbps, 32kbps and 48kbps).

AACLD

CD-quality audio, MPEG-4 Advanced Audio Coding Low Delay (20 kHz, stereo at 128kbps, mono at 64kbps).

Call Rate vs Audio algorithms selected Modify/remove algorithms used by unchecking the different audio algorithms. Automatically preferred audio algorithms on call rates up to and including 192kbps 1. G.722.1 (24kbps or 32kbps) 2. G.728 (16kbps) 3. AAC-LD (64kbps or 56kbps) 4. G.722 (56kbps, 64kbps or 48kbps)* 5. G.711 (64kbps, 56kbps or 48kbps)** 6. AAC-LD (48kbps or 128kbps) Automatically preferred audio algorithms on call rates above 192kbps 1. AAC-LD (128kbps)*** 2. AAC-LD (64kbps or 56kbps) 3. G.722 (64kbps, 56kbps or 48kbps)* 4. G.722.1 (32kbps or 24kbps) 5. G.728 (16kbps) 6. G.711 (64kbps, 56kbps, 48kbps)** 7. AAC-LD (48kbps or 128kbps) * G.722 at 64kbps is used in H.323 (IP) calls only. ** G.711 at 64kbps is used in SIP and H.323 (IP) calls only. *** Dependent on a call rate above the AAC-LD 128 threshold. Note that this is not available on all TANDBERG systems.

Page 167 of the TANDBERG Edge MXP user manual — 4.4.3 AAC-LD 128kbps (stereo audio)
Page 167 · click to enlarge
Page 167

4.4.3 AAC-LD 128kbps (stereo audio)

Specify a call rate for 128kbps AAC-LD. From this call rate and above, "128kbps AAC-LD" is available. On lower call rates "64kbps AAC-LD" is available. Stereo audio requires twice the bandwidth as mono CD-quality audio. Therefore we recommend enabling stereo audio on high call rates only. To enable stereo CD-quality audio you need to specify a call rate for when stereo automatically should be enabled. On lower call rates, mono CD-quality audio "64kbps AAC-LD" will be enabled. Stereo I/O mode needs to be enabled to get stereo audio, see Stereo Settings for details.

Administrator Settings

Page 168 of the TANDBERG Edge MXP user manual — 4.4.4 Natural Video
Page 168 · click to enlarge
Page 168

4.4.4 Natural Video

Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Continuous Presence MultiSite calls.

Auto Natural Video Auto will enable transmission of Natural Video from 768 kbps and above**. Reception of Natural Video is in this case always enabled.

Off Natural Video Off will disable both transmission and reception of Natural Video.

Custom 384 kbps and above to 1920 kbps and above.

* 50 fields per second on PAL systems. ** Will transmit 448p if supported by far end system.

Page 169 of the TANDBERG Edge MXP user manual — 4.4.5 Max Upstream Rate (kbps)
Page 169 · click to enlarge
Page 169

4.4.5 Max Upstream Rate (kbps)

The Max Upstream Rate (kbps) defines the desired maximum transmitted call rate. This is to be able to limit the outgoing bandwidth whilst keeping the maximum incoming bandwidth, especially useful for home offices with different upstream and downstream rates, typically ADSL.

Administrator Settings

Page 170 of the TANDBERG Edge MXP user manual — 4.4.6.1 Intelligent Video Management (IVM)
Page 170 · click to enlarge
Page 170

4.4.6 Video Quality

The different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default.

Motion* Optimized for smooth motion video (CIF/SIF or w288p for low bandwidths, 448p/400p, Interlaced CIF (iCIF) / Interlaced SIF (iSIF) or w448p for high bandwidths).

Sharpness* Optimized for sharp video (4CIF/4SIF, SVGA, XGA, w720p).

The system chooses the best of Motion or Sharpness depending on picture layout and bandwidth.

4.4.6.1 Intelligent Video Management (IVM)

It is possible to configure the picture sent from the system depending upon specific requirements and applications adding an additional level of flexibility and adaptability. Generally, the IVM will always try to transmit the format closest to the video input format. Each video input can be configured to either motion or sharpness: Motion*: When there is a need for higher frame rates, typically when a large number of participants are present or when there is a lot of motion in the picture.

At low bit rate:

ƒ CIF will be used from a PAL video input ƒ SIF from NTSC ƒ w288p from wide format (HD720p) input ƒ VGA/SVGA/XGA from PC, Digital Clarity At high bit rate:

ƒ 448p will be used from a PAL video input if Natural Video is ‘Off’ or ‘Auto’ or if Natural Video is ‘x kbps’ and the bit rate is lower than x kbps ƒ 400p from NTSC if Natural Video is ‘Off’ or ‘Auto’ or if Natural Video is ‘x kbps’ and the bit rate is lower than x kbps ƒ iCIF will be used from a PAL video input, if Natural Video is ‘x kbps’ and the bit rate is higher than or equal to x kbps ƒ iSIF from NTSC, if Natural Video is ‘x kbps’ and the bit rate is higher than or equal to x kbps ƒ w448p will be used from a wide format (HD720p) input ƒ VGA/SVGA/XGA from PC, Digital Clarity

Auto

Page 171 of the TANDBERG Edge MXP user manual — 4.4.6.2 Native Resolutions
Page 171 · click to enlarge
Page 171

Sharpness*: Improved quality of detailed images and graphics, lower frame rate, ideal for enhancing quality at lower bandwidths.

ƒ 4CIF will be used from a PAL video input, Digital Clarity ƒ 4SIF from NTSC, Digital Clarity ƒ w720p will be used from a wide format (HD720p) input ƒ VGA/SVGA/XGA from PC, Digital Clarity IVM Resolution The following table shows relationship between Transmission modes selected by the system when Motion or Sharpness is set in the Call Quality menu. IVM will use this table to optimize the Video quality, according to the capabilities of the remote system(s):

TANDBERG Edge MXP — 4.4.6.2 Native Resolutions diagram (page 171)
Fig. 78 · 4.4.6.2 Native Resolutions

MOTION PAL 448p -> iCIF@50 -> CIF -> QCIF

MOTION NTSC 400p -> 448p -> iSIF@60 -> iCIF@60 -> SIF -> CIF -> QCIF

MOTION Wide w448p -> w288p -> CIF -> QCIF

SHARPNESS PAL 4CIF -> VGA -> CIF -> QCIF

SHARPNESS NTSC 4SIF -> 4CIF -> VGA -> SIF -> CIF -> QCIF

SHARPNESS VGA VGA -> 4CIF -> CIF -> QCIF

SHARPNESS SVGA SVGA -> XGA -> 4CIF -> VGA -> CIF -> QCIF

SHARPNESS XGA XGA -> SVGA -> 4CIF -> VGA -> CIF -> QCIF

SHARPNESS Wide w720p -> w576p -> w448p -> w288p -> CIF -> QCIF

Transmission mode with Motion or Sharpness selections.

4.4.6.2 Native Resolutions

The following live video resolutions are supported on the system*: Native NTSC:

ƒ 4SIF (704 x 480 pixels), Digital Clarity ƒ 400p (528 x 400) ƒ iSIF (352 x 480 pixels), Natural Video ƒ SIF (352 x 240 pixels)

Administrator Settings

Page 172 of the TANDBERG Edge MXP user manual — 4.4.6.2 Native Resolutions
Page 172 · click to enlarge
Page 172

Native PAL:

ƒ 4CIF (704 x 576 pixels), Digital Clarity ƒ 448p (576 x 448) ƒ iCIF (352 x 576 pixels), Natural Video ƒ CIF (352 x 288 pixels) ƒ QCIF (176 x 144 pixels) ƒ SQCIF (128 x 96 pixels) Native PC Resolutions:

ƒ XGA (1024 x 768 pixels), Digital Clarity ƒ SVGA (800 x 600 pixels), Digital Clarity ƒ VGA (640 x 480 pixels), Digital Clarity Wide (16:9) Resolutions:

ƒ w288p (512 x 288 pixels) ƒ w448p (768 x 448 pixels) ƒ w576p (1024 x 576 pixels) ƒ w720p (1280 x 720 pixels) * Note that the TANDBERG 550 MXP and the TANDBERG 1000 MXP do not transmit the following video formats: 448p, 400p, iCIF, iSIF, w288p, w448p, w576p, and w720p.

Page 173 of the TANDBERG Edge MXP user manual — 4.4.7 Default Call Settings
Page 173 · click to enlarge
Page 173

4.4.7 Default Call Settings

Default Call Settings are connected with Call Settings in the call menu. If you leave Call Settings unchanged when making a call, the system will use the Default Call Settings in the call. In addition to the Call Settings Call Type, Net, Bandwidth and Restrict (56k), you also find settings for H.320 Auto bandwidth and H.323 Auto bandwidth in Default Call Settings.

Call Type can be set to:

ƒ Video Call ƒ Telephone Call If either the Call Type is set to Telephone Call or the Place Telephone Call icon is selected when making a call, the call will be set up as a telephone call. In all other cases the call will be set up as a video call. Some network configurations may cause the setup of a video call to fail. The call will then be set up as a telephone call instead if Fallback to Telephony is enabled. For MultiSite calls, Call Type enables you to specify both telephone calls and video calls in the same conference.

Network The Network alternatives are:

ƒ Auto ƒ ISDN ƒ H.323 ƒ SIP If Auto is selected, the system will select the right network depending on the entered number:

ƒ If an IP-address (e.g. 10.12.34.56 ) is entered, H.323 is selected. ƒ If the first digits in the number match those set in H.323 Prefix, H.323 is selected. ƒ In other cases, ISDN (H.320) is selected. ISDN indicates:

ƒ ISDN-BRI ƒ ISDN-PRI ƒ Leased E1/T1 ƒ External Networks If a gatekeeper is present, it is possible to place IP-calls using “telephone- style” numbers, e.g. an E.164 alias, according to the numbering plan implemented in the gatekeeper. The gatekeeper will then translate the dialed number into an IP-address, see H.323 Settings for more information about gatekeepers.

Administrator Settings · Call Type

Page 174 of the TANDBERG Edge MXP user manual — 4.4.7 Default Call Settings
Page 174 · click to enlarge
Page 174

Select ISDN to ensure that the call is set up as an ISDN call. Select H.323 to ensure that the call is set up as an H.323 call. Select SIP to ensure that the call is set up as an SIP call.

Bandwidth decides the quality of the video picture. When set to Auto the system will establish a connection using a proper bandwidth for the call, typically 384kbps for ISDN calls and 768kbps for IP calls. When set to Max the system will set up the call with maximum bandwidth depending on the selected network. Overview* Auto: 384 kbps on ISDN/768 kbps on LAN Max: 768 kbps on ISDN-BRI 1472/1920 kbps (23/30Ch) on ISDN-PRI (T1/E1) 4Mbps(4096 kbps, IP only) 4096 kbps = 4 Mbps, IP only 3072 kbps = 3 Mbps, IP only 2560 kbps = 2,5 Mbps, IP only 1920 kbps = 2 Mbps, 30B 1472 kbps = 23B 1152 kbps = 18B 768 kbps = 12B 512 kbps = 8B 384 kbps = 6B 320 kbps = 5B 256 kbps = 4B 192 kbps = 3B 128 kbps = 2B, Bonding/H.221 64 kbps = 1B, H.221 H0 = 1xH0, 384 kbps, PRI only * Note that some software versions and networks do not support all channel selections. Restrict (56k)

A restricted call uses 56kbps channels rather then the default unrestricted 64kbps channels. Some older networks (primarily in the USA) do not support 64kbps channels and require the use of restricted 56kbps calls. By default the system will dial an unrestricted call and downspeed to 56kbps if necessary. To force a restricted call, choose Restrict (56k) On.

H.221 or 2x64 (2x56) Calling Some older or low end video systems do not have the ability to make bonded ISDN calls. In these cases it is necessary to dial both ISDN numbers separately to call those systems.

Bandwidth

Page 175 of the TANDBERG Edge MXP user manual — 4.4.7 Default Call Settings
Page 175 · click to enlarge
Page 175

These types of calls are often referred to as

ƒ H.221 calls ƒ 2x64 calls ƒ 2x56 calls - as making 2 x 64 kbps or 2 x 56 kbps calls to the same system. Place this type of call by:

ƒ Set Network to ISDN ƒ Set Bandwidth to 128 kbps ƒ A field for the 2nd number pops up in Call Settings. ƒ Enter the second number in the Call Settings field. For 128 kbps calls that use bonding, ignore the second number field and just enter one number to be dialed. Using sub-address / extension address / MCU password Sub-address is used to address different systems on the same ISDN line and is primarily used in European Countries. LAN equivalent extension address or TCS-4 is used to address different systems on a LAN, when dialing via a gateway. To specify an ISDN sub-address or its LAN equivalent extension address (TCS-4), add a star (*) after the number and then enter the sub-address/extension address.

Example12345678*10 ( <number>*<Sub-address/extension address/MCU password>)

When dialing IP via a gateway, the number behind the star (*) on IP might be interpreted as an extension address. When calling to external MCU’s requiring a password (TSC-1), this password can be added after the star (*). If no password is specified, the user will be asked to enter the password (after connecting to the MCU).

Administrator Settings

Page 176 of the TANDBERG Edge MXP user manual — 4.5 Audio
Page 176 · click to enlarge
Page 176

4.5 Audio

TANDBERG Edge MXP — 4.5 Audio diagram (page 176)
Fig. 79 · 4.5 Audio

Audio contains the settings:

ƒ Inputs ƒ Outputs ƒ Echo Control ƒ Stereo Settings ƒ Audio Leveling (AGC) ƒ Alert Tones and Volume

Page 177 of the TANDBERG Edge MXP user manual — 4.5.1 Inputs
Page 177 · click to enlarge
Page 177

4.5.1 Inputs

Mic 1- 3 and Audio input 4-6 By default, all inputs are enabled. Just plug in an audio source and it is active. Audio inputs that are On will automatically be mixed. Unconnected inputs will automatically be muted. Select Off to prevent audio/noise from connected but unused inputs. The activated audio sources are stored on camera presets. Mic 1, 2 and 3 are intended for electrets type microphones. The microphone inputs are balanced with 24V phantom power. Audio input 4 is intended for connection to an external microphone amplifier or an external fixed mixer. It is crucial that the external mixer is a fixed mixer. Automatic, smart and other types of adaptive mixers might cause the echo canceller to malfunction. Audio input 5 is intended for connection to external playback devices or to telephone add-on hybrids. As there is no acoustic echo canceller on this input it should not be connected to any microphones. The audio source connected to this input will be heard from the local speaker as well. Audio input 6 is intended for connection to a VCR or DVD player. It can also be connected to other external playback devices. As there is no acoustic echo canceller on this input it should not be connected to any microphones. The audio entering this input will be heard from the local speaker as well. If Auto is selected, the audio from the VCR will only be heard when VCR is selected as video source. Mix Mode

The adjustment of each microphone signal is done automatically to obtain the best possible audio and minimize the background noise.

Fixed will maintain a constant weighting of all microphones.

VCR Ducking If VCR Ducking is activated, the VCR audio level will be attenuated if someone talks into the microphone or at the far end. The VCR ducking is only valid for audio input 6. If input 5 and 6 is configured to one stereo input pair, see Stereo Settings, then the VCR ducking will apply to both input 5 and 6. Level Settings

Administrator Settings · Auto · Fixed

Page 178 of the TANDBERG Edge MXP user manual — 4.5.1 Inputs
Page 178 · click to enlarge
Page 178

It is possible to adjust the audio input levels according to which external audio equipment is connected. The on-screen audio level indicator will make it easier to set the correct input level settings. The input level should be adjusted so that the average level reaches the transition between the green and the yellow area. The audio inputs are adjustable in steps of 1.5 dB from 0 dB to 22.5 dB.

TANDBERG Edge MXP — 4.5.1 Inputs diagram (page 178)
Fig. 80 · 4.5.1 Inputs

To help adjusting the input levels there is also a Peak Performance meter showing the peak audio volume for each of the audio inputs. The level should be adjusted so that the Peak Performance meter never reaches the maximum value to avoid the acoustic echo canceller to malfunction due to overload of the microphone. The default levels for Mic 1,2 and 3 are set for use with an Audio Technica AT871R or AT841R microphone in an average videoconferencing room. The gain can be adjusted correctly for a wide range of microphones. A few examples of microphone levels are: Audio Technica AT871R +3dB (default) Audio Technica AT841R +3dB TANDBERG Audio Science: Audio Technica AT-861PZ +3dB Crown PZM-6D +19.5dB Audio inputs 4, 5 and 6 are set to a default level which is adhered to by most manufacturers of audio-visual equipment and is a level at which most audio-visual equipment (CD-players, VCRs or DVDs) will work.

Page 179 of the TANDBERG Edge MXP user manual — -55.4 dB
Page 179 · click to enlarge
Page 179

-55.4 dB

TANDBERG Edge MXP — -55.4 dB diagram (page 179)
Fig. 81 · -55.4 dB
TANDBERG Edge MXP — -55.4 dB diagram (page 179)
Fig. 82 · -55.4 dB
TANDBERG Edge MXP — -55.4 dB diagram (page 179)
Fig. 83 · -55.4 dB

TANDBERG Audio Science microphone elements: Audio Technica AT-861PZ and Crown PZM- 6D

TANDBERG Edge MXP — -55.4 dB diagram (page 179)
Fig. 84 · -55.4 dB
TANDBERG Edge MXP — -55.4 dB diagram (page 179)
Fig. 85 · -55.4 dB

Administrator Settings

Page 180 of the TANDBERG Edge MXP user manual — 4.5.1 Inputs
Page 180 · click to enlarge
Page 180
TANDBERG Edge MXP — 4.5.1 Inputs diagram (page 180)
Fig. 86 · 4.5.1 Inputs

Table2: Signal Levels - Line level inputs Note that for the dBu value for input clipping level and absolute max output level, a sine waveform is assumed. If numbers in dBV are required, dBV value is 2.2 dB lower than the dBu value, e.q. - 10 dBu equals -12.2 dBV Please see Interfaces for details on the audio connectors.

Page 181 of the TANDBERG Edge MXP user manual — 4.5.2 Outputs
Page 181 · click to enlarge
Page 181

4.5.2 Outputs

Audio out 1 - 3 Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, televisions or audio amplifiers. Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on hybrid. The signal is a mix of audio from both the far end and local end (not from Audio in 5). Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix of audio from far end and local end (not from Audio in 6). Note that audio out 2 or audio out 3 never should be connected to a loudspeaker placed in the same room as the microphones connected to the system. This will cause “howling” and possible damage to the speaker system. If an output is Off, no audio will be sent to that output. Out 1 Mode If Out 1 Mode is set to Auto, the system will select analog or digital (SPDIF) mode dependent on the detected Audio Module. If a TANDBERG Digital NAM is detected then SPDIF mode will be selected, otherwise analog mode will be selected. Setting the Out 1 Mode to either Analog or SPDIF will override the auto-detected mode. See Stereo Settings for more information. Audio Module Select Audio Module according to the type of Audio Module installed if this is not automatically detected. The Audio Module setting is only available if the audio module of the system is unidentified. Level Settings Adjust the audio output levels according to the parameters of the external audio equipment connected. These levels should only be adjusted when installing new audio equipment. The default settings are correct for the TANDBERG Digital Natural Audio module and for most consumer electronics devices (televisions, VCRs, etc.). The volume keys on the remote control adjust the level of output 1 (the speaker output). The volume control has no effect on other outputs.

Administrator Settings

Page 182 of the TANDBERG Edge MXP user manual — 4.5.2 Outputs
Page 182 · click to enlarge
Page 182
TANDBERG Edge MXP — 4.5.2 Outputs diagram (page 182)
Fig. 87 · 4.5.2 Outputs

* Applies to Output 1 at volume setting 15. Note that for the dBu value for input clipping level and absolute max output level, a sine waveform is assumed. If numbers in dBV are required, dBV value is 2.2 dB lower than the dBu value, e.q. - 10 dBu equals -12.2 dBV Please see Interfaces for details on the audio connectors.

Page 183 of the TANDBERG Edge MXP user manual — 4.5.3 Echo Control
Page 183 · click to enlarge
Page 183

4.5.3 Echo Control

Mic 1-3 and Audio 4 Each of the 3 microphone inputs and Audio input 4 has a separate acoustic echo canceller. One echo canceller per input provides more sophisticated control than having one common canceller for all microphones. In addition to echo cancellation, the system has built-in noise reduction (NR). NR reduces constant background noise (e.g. noise from air-conditioning systems, cooling fans etc.). In addition, a high pass filter (Humfilter) reduces very low frequency noise.

On Echo control is normally set to On to prevent the far end from hearing their own audio. Once selected, echo cancellation is active at all times. The echo canceller continuously adjusts itself to the audio characteristics of the room and compensates for any changes it detects in the audio environment. If the changes in the audio conditions are very significant the echo canceller may take a second or two to re-adjust.

Off You can choose to switch off the echo canceller for the available audio sources. Echo Control should be switched Off if external echo cancellation or playback equipment is used.

Activates both Echo Control and Noise Reduction.

ƒ Place all microphones as far as possible from the loudspeakers. Minimum loudspeaker- microphone distance should be 2 meters (6.5 ft). ƒ It is recommended to place the microphones between 1 and 2 meters away from the persons speaking. By using several microphones, the ratio distance loudspeaker-to- mic/mic-to-speaker can be increased. Increasing this ratio improves the echo canceller performance. ƒ Place the microphones as far as possible from noise sources. ƒ Reduce the volume setting. Ensure that the loudspeakers do not distort the audio. ƒ The echo canceller tries to estimate the echo path from the speaker system to the microphones. Moving objects change this path; therefore try to avoid moving objects. Be especially aware of large objects and objects placed close to either the microphone or the speaker system as these objects will cause severe changes to the echo path. ƒ Avoid putting paper sheets etc. on the microphone. ƒ Avoid moving the microphone or loudspeaker. ƒ In the presence of low frequency noise, enable the noise reduction (NR).

Administrator Settings · On+NR

Page 184 of the TANDBERG Edge MXP user manual — 4.5.4 Stereo Settings
Page 184 · click to enlarge
Page 184

4.5.4 Stereo Settings

TANDBERG Edge MXP — 4.5.4 Stereo Settings diagram (page 184)
Fig. 88 · 4.5.4 Stereo Settings

Audio out 1 Audio out 2 Audio out 3

*Out 1 Mode: Auto/Analog/SPDIF is described in Outputs. **L+R = Left + Right When Stereo I/O Mode is Off and Stereo Speakers is Off, the output response will be a mono loudspeaker signal on Audio out 1, AUX on Audio out 2 and VCR on Audio out 3 regardless on the Out 1 Mode setting. In analog mode the Stereo Speaker On will provide a stereo loudspeaker signal on Audio out 1 and 2. If Stereo I/O Mode is On: Audio input 5 and 6 and audio output 2 and 3 will behave as a stereo input/output pair, VCR-left and right. The VCR Ducking and AGC setting for audio input 6 will in this case apply to both audio input 5 and 6. The Audio out 2 (VCR-left stereo channel) will be a mix of the microphones and the far end left channel. Audio out 3 (VCR-right stereo channel) will be a mix of the microphones and the far end right channel. (Note that stereo speakers set to on in analog mode will provide a different scheme, see table above for details). If Stereo I/O Mode is Off: Audio out 2 will be a mix of audio input 6, microphones and the far end (the received far end signal is either mono, or stereo that is summed left+right into mono in near end codec). Audio out 3 will be a mix of audio input 5, microphones and the far end. (Note that stereo speakers set to on in analog mode will provide a different scheme, see table above for details). Note that in SPDIF mode, you are able to receive stereo through Audio out 1 independent of the Stereo I/O mode setting.

Page 185 of the TANDBERG Edge MXP user manual — 4.5.4 Stereo Settings
Page 185 · click to enlarge
Page 185

If the system is connected to a Digital NAM, stereo sound on the loudspeakers shall be present if a stereo input signal is connected to the inputs VCR-Left and VCR-Right or a stereo signal is received from the Far End. If the system is not connected to a Digital NAM, stereo sound on the loudspeaker outputs will be present in the following situations:

ƒ If system is idle and a stereo input signal is connected to the inputs VCR-Left and VCR-Right. ƒ If system is in a call with mic off and a stereo input signal is connected to the inputs VCR-Left and VCR-Right, or a stereo signal is received from the Far End. ƒ Otherwise the Loudspeaker Left signal will be equal to Loudspeaker Right.

Administrator Settings

Page 186 of the TANDBERG Edge MXP user manual — 4.5.5 Audio Leveling (AGC)
Page 186 · click to enlarge
Page 186

4.5.5 Audio Leveling (AGC)

On Select On to allow automatic adjustments (Automatic Gain Control) of audio levels. When On, the AGC maintains the audio signal level at a fixed value by attenuating strong signals and amplifying weak signals. Very weak signals, i.e. noise alone, will not be amplified.

Off Audio leveling is not activated.

Note that to ensure correct behavior of the AGC, it is crucial that the levels on the input connectors are adjusted correctly using the audio input level settings. The AGC will not compensate for severe maladjustment of input levels. When applying a weak signal in the presence of strong background noise, the AGC might amplify the background noise as well as the signal. Therefore, in noisy environments, it is advisable to turn the AGC off.

Example: In most conferences, the participants will speak at different levels, and be at different distances from the microphones. As a result, some of the participants would be harder to hear than others. The AGC corrects this problem by automatically increasing the microphone levels when “quiet” or “distant” people speak, and by decreasing the microphone levels when “louder” people speak.

Page 187 of the TANDBERG Edge MXP user manual — 4.5.6 Alert Tones and Volume
Page 187 · click to enlarge
Page 187

4.5.6 Alert Tones and Volume

Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert Volume You may change the volume level for the selected ringing tone. Alert Speaker The system also has an internal, call-alerting speaker.

On The internal speaker will warn you of an incoming call even though the monitor may not be switched on.

Off The internal speaker is switched off.

On There will be a sound indicator when pressing keys on the remote control.

Off There will be no sound when pressing keys on the remote control.

Administrator Settings · Key Tones

Page 188 of the TANDBERG Edge MXP user manual — 4.6 Video
Page 188 · click to enlarge
Page 188

4.6 Video

TANDBERG Edge MXP — 4.6 Video diagram (page 188)
Fig. 89 · 4.6 Video

Video contains the settings:

ƒ Camera Tracking Mode ƒ MCU Status Line ƒ Floor to Full Screen ƒ Web Snapshots ƒ MultiSite Picture Mode ƒ Video Name

Page 189 of the TANDBERG Edge MXP user manual — 4.6.1 Camera Tracking Mode
Page 189 · click to enlarge
Page 189

4.6.1 Camera Tracking Mode

Slow The system waits a while before zooming in on a single person speaking. Suitable when wide-angle images are preferred over close-up images.

Normal Should be used in regular meetings.

The system quickly zooms in on a single person speaking. Suitable when close- ups are preferred over wide-angle images.

Administrator Settings · Fast

Page 190 of the TANDBERG Edge MXP user manual — 4.6.2 MCU Status Line
Page 190 · click to enlarge
Page 190

4.6.2 MCU Status Line

On The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference.

Off The MultiSite / MCU / DuoVideo indicators will not be displayed.

The MultiSite / MCU / DuoVideo indicators will be displayed for a few seconds and then timed out. When grabbing the remote control, the indicators will be shown again.

Auto

Page 191 of the TANDBERG Edge MXP user manual — 4.6.3 Floor to Full Screen
Page 191 · click to enlarge
Page 191

4.6.3 Floor to Full Screen

When "Floor to Full Screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "Floor to Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 layout will be seen in the large square, rather than full screen.

The participant that has the floor is displayed in full screen regardless of what MultiSite layout that is used.

Off The participant that has the floor is displayed in the MultiSite layout that is used.

Administrator Settings · On

Page 192 of the TANDBERG Edge MXP user manual — 4.6.4 Web Snapshots
Page 192 · click to enlarge
Page 192

4.6.4 Web Snapshots

The system is able to generate JPEG snapshots and provide them when requested (as ‘http get’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files.

Snapshots generation is enabled.

Off Snapshots generation is disabled.

On

Page 193 of the TANDBERG Edge MXP user manual — 4.6.5 MultiSite Picture Mode
Page 193 · click to enlarge
Page 193

4.6.5 MultiSite Picture Mode

MultiSite* Picture Mode determines the default layout of a MultiSite call. Available layouts are: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services.

Auto Split Auto Split displays all participants on the screen simultaneously. A MultiSite call with 3 or 4 video participants is displayed with 4 Split. A MultiSite call with 5 or 6 video participants is displayed with 5+1 Split.

Voice Switched mode displays the participant that is speaking in full screen.

4 Split 4 Split displays the 4 last speaking Participants.

5+1 Split displays the speaking participant in a big picture and the other participants in small pictures.

Continuous Presence layout 4 split

Advanced Continuous Presence Layout (5+1) - In this mode the Intelligent Call Management will use 4*CIF resolution for better clarity and H.263 video compression

Administrator Settings · Voice Switched · 5+1 Split

Page 194 of the TANDBERG Edge MXP user manual — 4.6.5 MultiSite Picture Mode
Page 194 · click to enlarge
Page 194

Voice Switched mode

Page 195 of the TANDBERG Edge MXP user manual — 4.6.6 Video Name
Page 195 · click to enlarge
Page 195

4.6.6 Video Name

As a default, the video inputs are given the names Main Cam, PC, Doc Cam, VCR, AUX or VNC, dependent on what video sources are available on your system. The video names cannot exceed eight characters. The names correspond to the video names in the Presentation Menu (Choose Presentation from the main menu and open the Main Video or Presentation Video pop up menu). If video names are changed, you will see the changed name appear in the Main Video and Presentation Video menus.

Administrator Settings

Page 196 of the TANDBERG Edge MXP user manual — 4.7 Security
Page 196 · click to enlarge
Page 196

4.7 Security

TANDBERG Edge MXP — 4.7 Security diagram (page 196)
Fig. 90 · 4.7 Security

Security contains the settings:

ƒ Encryption ƒ Encryption Mode ƒ Passwords

Page 197 of the TANDBERG Edge MXP user manual — 4.7.1 Encryption
Page 197 · click to enlarge
Page 197

4.7.1 Encryption

Auto The system will try to set up calls using encryption. Point to point calls: If the far end system supports encryption (AES or DES), the call will be encrypted. If not, the call will proceed without encryption. MultiSite calls*: In order to have encrypted MultiSite calls, all sites must support encryption. The padlock symbol will indicate encryption mode (AES or DES). If there is a mix of AES and DES encryption, only the symbol for DES encryption (single padlock) will be displayed. The 'closed padlock' will only be displayed on each site when all links in the MultiSite conference are encrypted. If the far end supports encryption, the systems will initiate encryption after the call is connected (an ‘open padlock’ symbol will be displayed). When encryption has been established, a ‘closed padlock’ symbol will be displayed.

On The system will only send and receive encrypted data. The call will not be established if not all participants support encryption.

Off The system will not send or receive encrypted data.

Technical encryption information like encryption algorithm and encryption check code can be found in the Call Status menu. * Only available on systems with MultiSite option supported and installed.

Administrator Settings · (Country specific)

Page 198 of the TANDBERG Edge MXP user manual — 4.7.2 Encryption Mode
Page 198 · click to enlarge
Page 198

4.7.2 Encryption Mode

The system will try to use the most secure encryption - AES, dependent on the capabilities of the other sites. For sites that do not support AES encryption, DES encryption will be tried.

AES The system will try to use AES with 128 bits encryption when setting up calls. If AES is not supported by the other site(s), no other type of encryption will be initiated.

DES The system will always try to set up the call using DES with 56 bits encryption on ISDN and IP. If all other sites do not support DES, no other type of encryption will be initiated.

Both AES and DES Encryption are supported for mixed ISDN/IP calls. In addition AES -and DES Encrypted sites can be connected at the same time.

Auto

Page 199 of the TANDBERG Edge MXP user manual — 4.7.3 Passwords
Page 199 · click to enlarge
Page 199

4.7.3 Passwords

Administrator Password, IP Access Password, Streaming Password, VNC Password, Access Code and Remote Software Upgrade password are duplicated from their respective menus. Using the Security menu gives you a quick way to change all passwords of the system.

Administrator Settings

Page 200 of the TANDBERG Edge MXP user manual — 4.8 Network
Page 200 · click to enlarge
Page 200

4.8 Network

The network menu contain:

ƒ ISDN/External/Leased E1/T1 ƒ LAN Settings ƒ Network Profiles ƒ Data Port

Page 201 of the TANDBERG Edge MXP user manual — ISDNPRI*
Page 201 · click to enlarge
Page 201

4.8.1 ISDN/External/Leased E1/T1

Before using the system it is necessary to specify which network to use and define its settings.

ISDNBRI

If you want to use your system via ISDN-BRI, you should select Network Type: ISDN-BRI and enter the ISDN BRI Settings menu to set the BRI parameters.

ISDNPRI*

If you want to use your system via ISDN-PRI, you should select Network Type: ISDN-PRI and enter the ISDN PRI Settings menu to set the PRI parameters.

If you want to use your system via Leased E1/T1, you should select Network Type: Leased E1/T1 and enter the Leased E1/T1 Settings (see Leased E1/T1 Settings) menu to set the Leased E1/T1 parameters.

External If you want to use special networks and connect using RS449, V.35, X.21 or connect to ISDN via an external IMUX, you should select Network Type: External and enter the External Network Settings (see External Network Settings menu to set the External Network parameters.

*Note that both Leased E1/T1 and ISDN-PRI uses the same interface on the codec marked E1/T1.

Administrator Settings · Network Type · Leased E1/T1*

Page 202 of the TANDBERG Edge MXP user manual — Line setup
Page 202 · click to enlarge
Page 202

4.8.1.1 ISDN-BRI Settings

To make sure your system will work properly using ISDN-BRI, make the following settings:

1. Set ISDN switch type 2. Enter ISDN line numbers (+ SPIDs if required) 3. Disable unused lines Some software versions do not support 6 ISDN lines, therefore some of the Line Setup entries may be grayed out.

ISDN BRI switch type

Select the type of ISDN network connected to your unit. Note that 1TR6 should only be used if you are operating the system behind a PABX.

Line setup

This menu allows you to program the numbers associated with your ISDN line. If you want to use this ISDN line, you need to set Enabled On and enter the numbers of your ISDN line. If some of the ISDN lines are not to be used, set Enabled Off. Line 1 should always be enabled. National ISDN and AT&T Custom ISDN might require SPID numbers associated with your ISDN numbers. If you have received two different SPID (Service Profile IDentifier) numbers for each ISDN line from your network provider, you must program both of them.

TANDBERG Edge MXP — Line setup diagram (page 202)
Fig. 91 · Line setup
Page 203 of the TANDBERG Edge MXP user manual — Advanced ISDN Settings
Page 203 · click to enlarge
Page 203

Advanced ISDN Settings

Sub address Using a sub address enables you to connect up to eight ISDN terminals to the same ISDN telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the ISDN telephone number and the sub address with a ‘*’. Note that this service is dependent on your service provider and has limited access on some ISDN networks.

Example: 12345678*2 (up to four digit sub addresses are possible).

Validate Numbers / MSN (Multiple Subscriber Number) The use of MSN (Multiple Subscriber Number) enables you to attach different ISDN terminals, with different numbers, to the same physical ISDN telephone line. If Validate Numbers is set to "On" only calls to those numbers specified in the Line Setup menus will be answered. If available this service can be ordered from your telephone company. Parallel dial

On Channels will be dialed and connected in parallel when setting up a BONDING call.

Off Channels will be dialed one by one, which may increase the dialing time.

On The system will send its own numbers to the far end.

Off The system will not send its own numbers to the far end, but please note that the network may still send your numbers to the far end.

On The system will send the ISDN message information element Sending Complete.

Off The system will not send Sending Complete. Default is “Off”

Administrator Settings · Send Own Numbers · Sending Complete

Page 204 of the TANDBERG Edge MXP user manual — Channel Hunting
Page 204 · click to enlarge
Page 204

4.8.1.2 ISDN-PRI Settings

To make sure your system will work properly using ISDN-PRI, configure the following settings:

1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable.

Number Range

Enter the range of numbers for your PRI line. If this number is programmed and MSN: On (see Validate numbers in Advanced ISDN Settings) only calls to this number will be answered.

ISDN PRI Switch Type

Select the type of PRI switch to which your system is connected. Below is a list of common ISDN-PRI/T1 switches.

Type Manufacturer PRI Switch Type setting

ATT 4 ESS ATT 5 ESS DMS 100 DMS 250

AT&T AT&T/Lucent Northern Telecom Telecom Northern

AT&T ISDN AT&T ISDN or National ISDN* National ISDN National ISDN

* Settings will depend on configuration of the switch. PRI Switch Type is not changed when Restoring Defaults.

Channel Hunting

Max Channels Maximum number of channels the system may use at any given time.

The lowest numbered B-channel that may be used by the system when selecting channels for outgoing calls.

High Channel The highest numbered B-channel that may be used by the system when selecting channels for outgoing calls.

Search Specifies where the system will start searching for available B-channels for outgoing calls.

Low Channel

Page 205 of the TANDBERG Edge MXP user manual — Advanced ISDN-PRI Settings
Page 205 · click to enlarge
Page 205

Example: Max Channels may be used for PRIs that are provisioned for a lower number of channels. High Channel, Low Channel and Search may be used for PRIs provisioned with specific requirements for B-channel usage.

In the example above, the system will start searching for available B-channels at channel 20, since Search is set to High and High Channel is set to 20. The system will not search for channels below 10, since Low Channel is set to 10. Furthermore if the user tries to make an 8 channel call, the call will be established with 6 channels, since Max Channels is set to 6.

Line Settings

T1 Cable Length 1

T1 Cable Length 1 specifies the distance to the CSU connected to the E1/T1 port 1 on codec 1.

E1-CRC-4

E1-CRC-4 is used for most E1-PRI configurations. You can turn it off if not supported by your E1 network equipment. For further information see Appendix 8: Connecting the system to PRI/T1.

Advanced ISDN-PRI Settings

NSF is a non standard facility. Your network provider may require a service selection in your ISDN configuration. Enter the Service code here. Valid NSF service codes are from 1 to 31. Enter 0 to disable NSF service codes.

Administrator Settings

Page 206 of the TANDBERG Edge MXP user manual — Table of contents
Page 206 · click to enlarge
Page 206

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 207 of the TANDBERG Edge MXP user manual — 4.8.1.3 Leased E1/T1 Settings
Page 207 · click to enlarge
Page 207

4.8.1.3 Leased E1/T1 Settings

Auto When Auto is selected, the system will automatically initiate a connection as soon as it detects that the far end tries to make a call. This mode is also commonly known as "data triggered" mode, because the existence of certain data patterns on the line triggers a connection.

Manual When manual is selected, the user has to explicitly issue a dial command to make the system connect to the far end system. Receiving an incoming call is not possible.

Network Interface Indicates if the network is of type E1 (30 channels) or T1 (24 channels). E1 will be default for PAL versions, T1 default for NTSC versions. Max Channels Indicates the maximum number of channels the codec is allowed to use on the E1/T1 interface. When E1 is selected, maximum is 30 channels. When T1 is selected, maximum is 24 channels. Start Channel Indicates the first E1/T1 channel the codec is allowed to use. This setting might be used if the E1/T1 line is shared with other equipment. T1 Line Coding Indicates how the signals on the line should be coded. If parts of the line between the systems use restricted coding, this should be selected.

Line Settings This is the same menu as for ISDN-PRI. Please refer to ISDN-PRI Settings.

Administrator Settings · Call Control

Page 208 of the TANDBERG Edge MXP user manual — 4.8.1.4 External Network Settings
Page 208 · click to enlarge
Page 208

4.8.1.4 External Network Settings

Before using the system together with external network equipment, you must specify the network parameters on this page. The system has support for up to 2 Mbps (depending on the Bandwidth key loaded) using the External Network (RS449/V.35/X.21) interface. Note that the physical interface on External Networks is one non-standard 26 pin connector. Special cables are required, see Interfaces for cable pinouts. Call Control

RS366 Dialing is the only dialing protocol supported and would normally be used together with network clocking RS449/V.35 Compatible when the external equipment uses RS366 ports.

RS366 Adtran ISU 512

RS366 Adtran ISU 512 offers extra usability when dialing RS366 via an ADTRAN ISU 512 IMUX. This dialing scheme will map the call type and bandwidth selection to ADTRAN ISU 512 specific suffixes to the dialed number. Should only be used when connected to an ADTRAN ISU 512. The Adtran ISU512 uses the following suffixes #C#R #C = Call Type #2 = audio #3 = 56kbps #4 = 64kbps #R = Channel Rate #0 = 2xh221 (2x56\64kbps) #1 to 8 = the Call Rate.

Leased Line is a non-dialing protocol and should be used when two codecs are connected in a point-to-point connection. Use Leased Line when the handshaking signals DTR and CD are available. DTR and CD correspond to the X.21 network’s C and I signals.

Data Triggered mode uses TxData (transmit data), RxData (receive data) and clock signals only. Use Data Triggered when no handshake signals are available.

Manual Manual should be used when no handshake signals are available and the external equipment requires a constantly connected line.

RS366 Dialing · Leased Line · Data Triggered

Page 209 of the TANDBERG Edge MXP user manual — 4.8.1.4 External Network Settings
Page 209 · click to enlarge
Page 209

Network clocking The network clock setting specifies the number of physical external clock signals.

Use RS449/V35 Compatible when the external equipment provides two clock signals, one for transmit and one for receive. The difference between RS449 and V35 is only the cable.

Use X21 Compatible when the external equipment provides a common clock signal for both transmits and receives.

Administrator Settings · RS449/V35 Compatible · X21 Compatible

Page 210 of the TANDBERG Edge MXP user manual — 4.8.1.5 H.331 Settings
Page 210 · click to enlarge
Page 210

4.8.1.5 H.331 Settings

On Used when broadcasting a videoconference from one site to many others, e.g. via satellite, where there is no possibility to negotiate quality between the receivers and the originator due to one-way communication.

Off Standard two-way communication with quality negotiation between both sides.

Page 211 of the TANDBERG Edge MXP user manual — 4.8.2 LAN Settings
Page 211 · click to enlarge
Page 211

4.8.2 LAN Settings

LAN Settings contain:

ƒ IP Settings ƒ H.323 Settings ƒ SIP Settings ƒ SNMP Settings ƒ IP Services ƒ Quality of Service ƒ 802.1X Settings

Administrator Settings

Page 212 of the TANDBERG Edge MXP user manual — 4.8.2.1 IP Settings
Page 212 · click to enlarge
Page 212

4.8.2.1 IP Settings

Remember to restart the system after making changes to IP Settings. This can be done by selecting the “Save and Restart” at the bottom of the IP setting menu. Changes in IP Settings menu will not have any effect until the system is restarted. IP Protocol

IPv4 IP version 4 supported.

IP version 6 supported. IP Address, IP Subnet Mask and Gateway will be disabled.

Both Both IP version 4 and IP version 6 supported.

IP-assignment DHCP (Dynamic Host Configuration Protocol) can be selected when a DHCP server is present. Note that for IPv6, DHCP is used for NTP / DNS Server Addresses.

DHCP IP-address, IP-subnet mask and Gateway are not used because the DHCP server assigns these parameters.

Static The system’s IP-address, IP-subnet mask and Gateway must be specified in the IP- address field.

IP-address IP-address defines the network address of the codec. This address is only used in static mode. In DHCP-mode, the assigned IP-address can be found on the Welcome Menu. IP-subnet mask IP-subnet mask defines the type of network. This address is only used in static mode. Your LAN- administrator will provide the correct value for this field. Gateway When using DHCP, the default gateway will be set automatically. If the LAN utilizes static IP addresses, IP address, subnet mask, and default gateway must be specified by the LAN administrator.

IPv6

Page 213 of the TANDBERG Edge MXP user manual — 4.8.2.1 IP Settings
Page 213 · click to enlarge
Page 213

Auto The codec will auto-detect the speed/duplex on the LAN.

10/Half The codec will connect to the LAN using 10Mbps speed/Half Duplex.

10/Full 10 Mbps speed/Full Duplex.

100/Half 100 Mbps speed/Half Duplex.

100/Full 100 Mbps speed/Full Duplex.

IP Access Password By setting an IP Access Password on the system, all access to the system using IP (Telnet, FTP and WEB) requires a password. The default IP Access Password is “TANDBERG”.

Administrator Settings · Ethernet Speed

Page 214 of the TANDBERG Edge MXP user manual — DNS Settings
Page 214 · click to enlarge
Page 214

DNS Settings

DNS Server 1-5 DNS Server defines the network addresses for DNS servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default domain name suffix which is added to unqualified names.

Example: DNS Domain Name is “example.com”, and the name to lookup is “videosystem” will result in a “videosystem.example.com” DNS lookup.

Page 215 of the TANDBERG Edge MXP user manual — 4.8.2.2 H.323 Settings
Page 215 · click to enlarge
Page 215

4.8.2.2 H.323 Settings

E.164 alias This is the E.164 address of the system. The E.164 address is equivalent to a telephone number, sometimes combined with access codes. Valid characters are 0-9,* and #. When using a gatekeeper, the system will send a message to the gatekeeper containing both the E.164 address and the H.323 ID of the system. H.323 ID The H.323 ID of the system may be specified here. The System name is used if no H.323 ID is entered.

H.323 Call Setup

Direct An IP-address must be dialed in order to make a H.323 call. The system will not use a gatekeeper or CallManager

Gatekeeper The system will use a gatekeeper to make an H.323 call.

The system will use a CallManager to make a H.323 call.

H.323 Prefix When dialing a number prefixed with digits specified by H.323 Prefix, and with Net: Auto, an H.323 call will be placed.

Example: H.323 Prefix is "555". Dialing "55582" with "Net:Auto" will select LAN.

Administrator Settings · CallManager

Page 216 of the TANDBERG Edge MXP user manual — Gatekeeper Settings
Page 216 · click to enlarge
Page 216

Gatekeeper Settings

Auto The system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the gatekeeper as well. If no gatekeeper responds, the system will not use a gatekeeper for making H.323 calls and hence an IP-address must be specified manually.

Manual The system will use a specific gatekeeper identified by Gatekeeper IP-address.

Gatekeeper IP Address This is the gatekeeper IP-address that is used if you specify H.323 Call Setup: Gatekeeper and Gatekeeper Discovery: Manual.

Auto If Authentication Mode is set to Auto and the gatekeeper indicates that it requires authentication, the endpoint will automatically try to authenticate itself to the Gatekeeper.

Off If Authentication Mode is set to Off the system will not try to authenticate itself to a Gatekeeper, but will still try a normal registration.

Authentication ID / Authentication Password The system sends the Authentication ID and Password to a Gatekeeper for authentication. The authentication is a one way authentication from the endpoint system to a Gatekeeper, i.e. the endpoint is authenticated to the Gatekeeper. If the Gatekeeper indicates that no authentication is required, the endpoint will still try to register.

Gatekeeper Discovery · Authentication Mode

Page 217 of the TANDBERG Edge MXP user manual — CallManager Settings
Page 217 · click to enlarge
Page 217

CallManager Settings

CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.

Administrator Settings

Page 218 of the TANDBERG Edge MXP user manual — Advanced H.323 Settings
Page 218 · click to enlarge
Page 218

Advanced H.323 Settings

The Advanced H.323 Settings only have an effect if they are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used when a PC and a videoconferencing system are connected to a router with NAT support. NAT support in the videoconferencing system enables proper exchange of audio/video data when connected to an external videoconferencing system (when the IP traffic goes through a NAT router). When NAT is On, the NAT Server Address will be shown in the startup-menu: "My IP Address: 10.0.2.1".

On The system will signal the configured "NAT Address" in place of its own IP-address within Q.931 and H.245.

Auto The system will try to determine if the "NAT Address" or the real IP-address should be used within signaling. This is done to make it possible to place calls to endpoints on the LAN as well as endpoints on the WAN.

NAT Address This must be the external/global IP-address to the router with NAT support. Packets sent to the router will then be routed to the system. In the router, the following ports must be routed to the system’s IP-address:

Port 1720 Port 5555-5560 Port 2326-2365

Please contact your TANDBERG representative for further information. RSVP

Auto Resource Reservation Protocol enables the systems to request the optimal amount of bandwidth for the duration of an IP videoconference.

Off Resource Reservation Protocol is switched off.

H.323 Ports

Static When selecting static H.323 ports for TCP connections the ports 5555 to 5574 will be used for Q.931 and H.245 respectively.

Dynamic The system will allocate which ports to use when opening a TCP connection. The reason for doing this is to avoid using the same ports for subsequent calls as some firewall consider this as a sign of attack.

Page 219 of the TANDBERG Edge MXP user manual — Display Name
Page 219 · click to enlarge
Page 219

4.8.2.3 SIP Settings

On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls.

Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system.

Display Name

The Display name part of the SIP Address (URI) is usually a full name or system name.

Examples“Alice Wonderland” “System 01”

SIP Address The SIP Address is the SIP URI used to address the system. SIP Address (URI):

Examples“alice@ example.com ” “1234” “1234@ example.com ”

Administrator Settings · Mode · Server Discovery

Page 220 of the TANDBERG Edge MXP user manual — Current RFC’s and Drafts supported:
Page 220 · click to enlarge
Page 220

The Server Address is the manually configured address for the outbound proxy and registrar. It is possible to use a fully qualified domain name, or an IP address. The default port is 5060 for TCP and UDP, but another one can be provided. Server Address:

Examples“sipserver. example.com ” “sipserver. example.com :5060” “10.0.0.2” “10.0.0.2:5061”

Authentication

User Name This is the user name part of the credentials used to authenticate toward the SIP Server. User name: Password This is the password part of the credentials used to authenticate toward the SIP Server. Password: Server Type Available servers are: Auto, Nortel, Microsoft and Experimental

Current RFC’s and Drafts supported:

ƒ RFC 3261 SIP: Session Initiation Protocol ƒ RFC 2327 SDP: Session Description Protocol ƒ RFC 3264 An Offer/Answer Model with the Session Description Protocol (SDP) ƒ RFC 3263: Session Initiation Protocol (SIP): Locating SIP Servers - No support for NAPTR records. ƒ RFC 3311 The Session Initiation Protocol (SIP) UPDATE Method ƒ RFC 2976 SIP INFO Method

ƒ Draft-levin-mmusic-xml-media-control-03.txt - Used for video fast picture update requests ƒ RFC 3361 Dynamic Host Configuration Protocol (DHCP-for-IPv4) Option for Session Initiation Protocol (SIP) Servers ƒ RFC 3550 RTP: A Transport Protocol for Real-Time Applications ƒ RFC 2032 RTP Payload Format for H.261 Video Streams

ƒ Draft-ietf-avt-rfc2032-bis-06.txt - Draft for advanced video signaling including resolution and mpi. ƒ RFC 2190 RTP Payload Format for H.263 Video Streams

Page 221 of the TANDBERG Edge MXP user manual — Media Capabilities supported in SIP:
Page 221 · click to enlarge
Page 221

ƒ RFC 2429 RTP Payload Format for the 1998 Version of ITU-T Rec. H.263 Video (H.263+)

ƒ Draft-ietf-avt-rfc2429-bis-05.txt - Draft for advanced video signaling including resolution, mpi, annexes and custom formats. ƒ RFC 3047 RTP Payload Format for ITU-T Recommendation G.722.1 ƒ RFC3581 An Extension to the Session Initiation Protocol (SIP) for Symmetric Response Routing ƒ RFC3984 RTP Payload Format for H.264 Video ƒ RFC3016 RTP Payload Format for MPEG-4 Audio/Visual Streams

Media Capabilities supported in SIP:

Audio: PCMU (G.711 u-law) PCMA (G.711 a-law) G.722 64 kbps G722.1 24kbit G.722.1 32 kbps Video: H.261: QCIF 1/30, CIF 1/30 H.263: SQCIF 1/30, QCIF 1/30, CIF 1/30, 4CIF 2/30 H.263++: XGA 4/30, SVGA 3/30, VGA 2/30, SQCIF 1/30, QCIF 1/30, CIF 1/30, 4CIF 2/30 H.264: XGA 4/30, SVGA 3/30, VGA 2/30, SQCIF 1/30, QCIF 1/30, CIF 1/30, 4CIF 2/30

Administrator Settings

Page 222 of the TANDBERG Edge MXP user manual — 4.8.2.4 SNMP Settings
Page 222 · click to enlarge
Page 222

4.8.2.4 SNMP Settings

SNMP Settings SNMP Trap Host identifies the IP-address of the SNMP manager. SNMP (Simple Network Management Protocol, SNMP Ver 1) is used for monitoring and configuring of different entities in a network. The system's SNMP Agent responds to requests from SNMP Managers (a PC program etc.). SNMP traps are generated by the agent to inform the manager about important events. Traps can be sent to multiple SNMP Trap Hosts. Enter the IP address of up to three SNMP managers. All traps will then be sent to the hosts listed. SNMP Community names are used to authenticate SNMP requests. SNMP requests must have a ‘password’ in order to receive a response from the SNMP agent in the codec. Note that the SNMP Community name is case sensitive. The default password is "public".

Page 223 of the TANDBERG Edge MXP user manual — 4.8.2.5 IP Services
Page 223 · click to enlarge
Page 223

4.8.2.5 IP Services

NTP IP This is the NTP time server address from which the system can get updated time information. This is a requirement for proper operation if H.235 authentication is implemented. The Network Time Protocol (NTP) is used to synchronize the time of the system to a reference time server. The NTP IP setting holds the IP address to a time source where the system can get the exact time. The time server will subsequently be queried every 24th hour for time updates. The system will use the time to timestamp messages transmitted to Gatekeepers or Border Controllers requiring H.235 authentication.

Administrator Settings

Page 224 of the TANDBERG Edge MXP user manual — 4.8.2.6 Quality of Service
Page 224 · click to enlarge
Page 224

4.8.2.6 Quality of Service

TANDBERG Edge MXP — 4.8.2.6 Quality of Service diagram (page 224)
Fig. 92 · 4.8.2.6 Quality of Service

Diffserv Diffserv QoS method is used. Please see below for details.

IP Precedence QoS method is used. Please see below for details.

IP Precedence Video Used to define which priority audio, video, data and signaling should have in the network. The higher the number, the higher the priority. The priority ranges from 0(off) - 7 for each type of packets. Auto will provide the following priority:

Audio Video Data Signaling

4 4 3 6

IP Type of Service (TOS) helps a router select a routing path when multiple paths are available.

TANDBERG Edge MXP — 4.8.2.6 Quality of Service diagram (page 224)
Fig. 93 · 4.8.2.6 Quality of Service

IP Precedence Telephony Used to define which priority audio should have in the network for telephone calls. The higher the number, the higher the priority. The priority ranges from 0(off) - 7 for each type of packets.

QoS Type

Page 225 of the TANDBERG Edge MXP user manual — 4.8.2.6 Quality of Service
Page 225 · click to enlarge
Page 225

Auto will provide the following priority:

Diffserv Video Used to define which priority Audio, Video, Data and Signaling packets should have in an IP network. The priority ranges from 0 to 63 for each type of packets. Diffserv Telephony Used to define which priority Audio packets should have in an IP network for telephone calls. The priority ranges from 0 to 63 for each type of packets.

Administrator Settings · Audio

Page 226 of the TANDBERG Edge MXP user manual — EAP-PEAP
Page 226 · click to enlarge
Page 226

4.8.2.7 IEEE 802.1x

802.1X The system may be connected to an IEEE 802.1x LAN network. Supported 802.1x protocols are EAP-MD5, EAP-PEAP and EAP-TTLS. The 802.1x authentication are enabled by setting 802.1x Mode to On.

TANDBERG Edge MXP — 4.8.2.7 IEEE 802.1x diagram (page 226)
Fig. 94 · 4.8.2.7 IEEE 802.1x

Anonymous Identity The 802.1x Anonymous ID string is to be used as unencrypted identity with EAP types that support different tunneled identity, EAP-PEAP and EAP-TTLS. The anonymous ID, if set, will be used for the initial (unencrypted) EAP Identity Request. Identity The 802.1x Username is the username needed for 802.1x authentication. Password The 802.1x Password is the password needed for 802.1x authentication. EAP-MD5

TANDBERG Edge MXP — 4.8.2.7 IEEE 802.1x diagram (page 226)
Fig. 95 · 4.8.2.7 IEEE 802.1x

EAP_TTLS

TANDBERG Edge MXP — EAP_TTLS diagram (page 226)
Fig. 96

EAP-PEAP

TANDBERG Edge MXP — EAP-PEAP diagram (page 226)
Fig. 97
Page 227 of the TANDBERG Edge MXP user manual — 4.8.3 Network Profiles
Page 227 · click to enlarge
Page 227

4.8.3 Network Profiles

This menu consists of 7 network profiles; a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialed.

Example: 0 is added as a Call Prefix to the 2nd profile, ISDN. If you enter 12345678 in the dial menu and select ISDN, the number dialed will be 012345678.

Using the three last profiles you can enter the name of a profile, prefix and network selection. This is useful if you have a fixed prefix for your service provider.

Administrator Settings

Page 228 of the TANDBERG Edge MXP user manual — 4.8.4 Data Port
Page 228 · click to enlarge
Page 228

4.8.4 Data Port

The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable. Baud Rate, Parity, Databits and Stopbits If you wish to connect a PC to Data port 1, you must ensure that the PC and the system are identically configured. The available settings are:

Baud Rate Parity Databits Stopbits

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 None, Odd, Even 7, 8 1, 2

The control interface provided by the data port supports a subset of the Hayes command set as well as a comprehensive set of system specific commands. It maintains communication with the data port’s command interpreter at all times. All features available from the hand-held remote control can be accessed through the data port. Data Port 2 Data port 2 is dedicated to the main camera and will not be available in standard configuration. The Data Port 2 menu contains the same items as the Data Port 1 menu; Baud rate, Parity, Databits, Stopbits except for the Mode, which has VISCA and Auto selections Mode. The system will automatically detect WAVE cameras. If you are using a camera supporting the VISCA protocol, select Mode: VISCA. If Mode is Auto and no camera is connected to the Data port 2, the Baud rate, Parity, Databits and Stopbits settings will be enabled.

Page 229 of the TANDBERG Edge MXP user manual — 4.8.5 Restore Default Settings
Page 229 · click to enlarge
Page 229

4.8.5 Restore Default Settings

Restore Default Settings will restore all administrator settings. Note that this will not affect your Call Directory information, Network Type, Line Setup numbers or your SPID numbers.

Administrator Settings

Page 230 of the TANDBERG Edge MXP user manual — 5 Peripheral Equipment
Page 230 · click to enlarge
Page 230

5 Peripheral Equipment

Using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect peripheral equipment to your system. First of all however, we recommend you examine Interfaces, with details on the available connectors on the back of the system Codec. Peripheral Equipment contains:

ƒ Interfaces ƒ Document Camera ƒ VCR / DVD ƒ Additional Cameras ƒ Additional Microphones ƒ TANDBERG DNAM and Speakers ƒ Stereo Speaker Kit ƒ Telephone Add-On ƒ Dual Monitor ƒ XGA Monitors and Projectors ƒ VESA Display Power Management ƒ Digital Monitor Power Management ƒ Extended Display Identification

Page 231 of the TANDBERG Edge MXP user manual — 5.1.1 Video
Page 231 · click to enlarge
Page 231

5.1 Interfaces

TANDBERG Edge MXP — 5.1 Interfaces diagram (page 231)
Fig. 98 · 5.1 Interfaces

5.1.1 Video

5 Video Inputs: ƒ 2 video inputs supporting S-Video through Mini-DIN connectors. ƒ 2 video inputs supporting composite signals through RCA connectors. ƒ 1 VGA/DVI-I (DVI = Digital Video Interface, I = Integrated Digital & Analog) input, analog or digital. ƒ (use VNC as a 6th video input). The standard camera uses one of the S-Video inputs. Levels:

ƒ Composite1 Vpp, 75 ohm ƒ S-Video (Y/C):

ƒ Y: 1 Vpp, 75 ohm ƒ C (PAL): 0.3 Vpp, 75 ohm ƒ C (NTSC): 0.28 Vpp, 75 ohm The system will automatically adapt to a PAL or NTSC input.

VGA formats supported on 'DVI-I in': SVGA (800x600) 60Hz, 72Hz, 75Hz, 85Hz XGA (1024x768) 60 Hz, 70Hz, 75Hz SXGA (1280x1024) 60Hz HD720p (1280x720) 50,60 Hz

6 Video Outputs: ƒ 2 S-Video outputs, Mini-DIN connectors. ƒ 2 composite video outputs, RCA connectors. ƒ 2 VGA/DVI-I (DVI = Digital Video Interface, I = Integrated Digital & Analog) output, analog or digital. The first Mini-DIN connector and the first RCA connector provide main video (incoming/outgoing video and menus). The two other connectors provide selfview/snapshot/Duo Video. The S-Video outputs are used by default by the monitors. The outputs are always active. The format of the output will be either PAL or NTSC depending on your country’s standard video format.

Peripheral Equipment

Page 232 of the TANDBERG Edge MXP user manual — Interfaces
Page 232 · click to enlarge
Page 232

Levels:

ƒ Composite1 Vpp, 75 ohm ƒ S-Video (Y/C):

ƒ Y: 1 Vpp, 75 ohm ƒ C (PAL): 0.3 Vpp, 75 ohm ƒ C (NTSC): 0.28 Vpp, 75 ohm

VGA formats supported on 'DVI-I out': SVGA (800x600) 75Hz XGA (1024x768) 60Hz WXGA (1280x768) 60Hz HD720p (1280x720) 50,60 Hz

DVI and specifications: DVI stands for Digital Video Interface, and is a form of video interface technology made to maximize the quality of flat panel LCD monitors and high-end video graphics cards. The TANDBERG codec contains a DVI-I plug that can transmit either digital DVI signals or standard analog VGA signals, depending on what type of monitor is connected. DVI Specifications TANDBERG DVI-I follows the VESA Monitor Timing Standard v1.08, also knows as Display Monitor Timing (DMT). The resolution used when showing a PAL image like the WAVE II is:

ƒ 800x600 @ 75Hz. The resolution used when showing a NTSC image like the WAVE II is:

ƒ 1024x768 @ 60Hz.

Page 233 of the TANDBERG Edge MXP user manual — Interfaces
Page 233 · click to enlarge
Page 233

Supported DVI cables: TANDBERG supports DVI-D Single-Link, DVI-A and DVI-I Single-Link format cables. DVI-D cables transmit digital T.M.D.S. signals, DVI-A cables transmit analog VGA signals and DVI-I cables can transmit either digital or analog signals. It is possible to extend existing DVI cables by the use of extension cables. The maximum cable length however, is 5 meters. Going beyond that may result in quality loss.

TANDBERG Edge MXP — Interfaces diagram (page 233)
Fig. 99 · Interfaces

6 DDC Clock 14 +5V Power 22 T.M.D.S. Clock Shield

7 DDC Data 15 Ground (return for +5V, HSync and VSync)

C1 Analog Red C2 Analog Green C3 Analog Blue

C5 Analog Ground (analog, R, G & B return)

Peripheral Equipment

Page 234 of the TANDBERG Edge MXP user manual — Interfaces
Page 234 · click to enlarge
Page 234
TANDBERG Edge MXP — Interfaces diagram (page 234)
Fig. 100 · Interfaces

PC cable, VGA - DVI with integrated audio

TANDBERG Edge MXP — Interfaces diagram (page 234)
Fig. 101 · Interfaces

PC cable, VGA - DVI with integrated audio

Page 235 of the TANDBERG Edge MXP user manual — 5.1.2 Audio
Page 235 · click to enlarge
Page 235

5.1.2 Audio

6 Audio Inputs: ƒ 3 microphone inputs (balanced, 24V phantom powered) via XLR connectors. ƒ 3 audio inputs (line level) via RCA connectors. All audio inputs are active by default. For further information, refer to chapter Audio. Audio input connector specification:

TANDBERG Edge MXP — 5.1.2 Audio diagram (page 235)
Fig. 102 · 5.1.2 Audio

Connector (codec) XLR-F, pin 1-gnd, pin 2 hot, pin 3- cold/neutral

Input impedance 2400 ohms (pin 2 - 3) 10K ohms

Max input level when set to minimum input level

Max input level when set to maximum input level

22.5 dB (16 steps of 1.5 dB) 22.5 dB (16 steps of 1.5 dB)

3 Audio Outputs: ƒ 1 output (line level) via RCA connector providing audio from far end, in addition to dial tones. This output also supports S/PDIF. S/PDIF (Sony/Philips Digital Interface) is used by the Digital Natural Audio module. ƒ 1 AUX output (line level) via RCA connector providing a mixed signal between audio from the local side (except from the AUX input) and audio from the far end. This output is intended for connection to a telephone add-on system. When system is configured as stereo, this output will provide the left stereo information. ƒ 1 VCR output (line level) via RCA connector providing a mixed signal between audio from the local side (except from the VCR input) and audio from the far end. This output is intended for connection to a VCR. When system is configured as stereo, this output will provide the right stereo information.

Peripheral Equipment

Page 236 of the TANDBERG Edge MXP user manual — 5.1.3 Network
Page 236 · click to enlarge
Page 236

Audio output connector specification:

Connector label Audio outputs

Connector (codec) Female RCA/phono, sleeve-ground, centre-signal

Output impedance 680 ohms

Max output level when set to maximum output level and volume control set to max. Max output level when set to minimum output level and volume control set to max.

15.5 Vpp 1.2 Vpp

Range, menu adjustable output gain

22.5 dB (16 steps of 1.5 dB)*

Volume control attenuation (audio out 1)

0 to 21 dB + mute (steps of 1.5 dB)

* Additional attenuation is possible on room/loudspeaker audio output using the volume control setting

5.1.3 Network

Ethernet: 1 x Ethernet (RJ-45 Jack) LAN interface (10/100 Mb) up to 4 or 6 Mbps depending on the bandwidth option installed. To connect the system to a LAN, use the Ethernet cable provided by TANDBERG (or a standard Ethernet cable). The cable specification is: 1 1 2 2 3 3 6 6 If no LAN is available and the codec is connected directly to a computer, use a crossover cable. The crossover cable specification is:

TANDBERG Edge MXP — 5.1.3 Network diagram (page 236)
Fig. 103 · 5.1.3 Network

If such a connection is needed, the system and the PC must use ‘static’ TCP/IP settings because no DHCP server is controlling the small “LAN”, which has been created between the computer and the system. When configuring a back-to-back connection between the PC and the system, make sure both static IP addresses exist on the same subnet.

Signal type Unbalanced

Page 237 of the TANDBERG Edge MXP user manual — 5.1.3 Network
Page 237 · click to enlarge
Page 237

ISDN BRI Interface: ISDN I.420 (RJ-45 Jack) Basic Rate Interface S/T (2B+D), 128 kbps per ISDN I/F To connect the system to BRI, use the ISDN cable provided by TANDBERG (or a standard BRI cable). The pinout of the S/T interface is:

ISDN PRI Interface: 1 x PRI (RJ-45 Jack) Primary Rate & Leased Line E1/T1 (G.703) Interface up to 2 Mbps 1 x PRI (RJ-45 Jack) Primary Rate (for future use). To connect the system to PRI, use the ISDN cable provided by TANDBERG (or a standard PRI cable). The pinout of the E1/T1 interface is:

TANDBERG Edge MXP — 5.1.3 Network diagram (page 237)
Fig. 104 · 5.1.3 Network
Show 6 more labels / short text on this page
Peripheral Equipment · BRI Pinout · Pin-3 TX+ · Pin-4 RX+ · Pin-5 RX- · Pin-6 TX-
Page 238 of the TANDBERG Edge MXP user manual — V35:
Page 238 · click to enlarge
Page 238

V35:

TANDBERG Edge MXP — V35: diagram (page 238)
Fig. 105

V.10 (RS423). For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal B. For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to GND. Cable length max: Leased Line Control = 20 Meter

Page 239 of the TANDBERG Edge MXP user manual — RS449:
Page 239 · click to enlarge
Page 239

RS449:

TANDBERG Edge MXP — RS449: diagram (page 239)
Fig. 106

RS366: All balanced inputs and outputs (A and B) use balanced line signals according to V.11 (RS422) and single ended signals in accordance with V.10 (RS423). For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal B. For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to GND. Cable length max: Leased Line Control = 20 Meter

Peripheral Equipment

Page 240 of the TANDBERG Edge MXP user manual — 5.1.3 Network
Page 240 · click to enlarge
Page 240
TANDBERG Edge MXP — 5.1.3 Network diagram (page 240)
Fig. 107 · 5.1.3 Network

All signals are electrically according to RS232. Cable length max: 5 meter X21:

TANDBERG Edge MXP — 5.1.3 Network diagram (page 240)
Fig. 108 · 5.1.3 Network
Page 241 of the TANDBERG Edge MXP user manual — 5.1.3 Network
Page 241 · click to enlarge
Page 241

All balanced inputs and outputs (A and B) use balanced line signals according to V.11 (RS422) and single ended signals in accordance with V.10 (RS423). For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal B. For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to GND. Cable length max: 50 meter

Peripheral Equipment

Page 242 of the TANDBERG Edge MXP user manual — 5.1.4 Data port
Page 242 · click to enlarge
Page 242

5.1.4 Data port

The data port(s) are implemented as Data Communications Equipment (DCE). The connectors used are female 9-pin D-subs. The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides 12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.

TANDBERG Edge MXP — 5.1.4 Data port diagram (page 242)
Fig. 109 · 5.1.4 Data port
Page 243 of the TANDBERG Edge MXP user manual — 5.2 Document Camera
Page 243 · click to enlarge
Page 243

5.2 Document Camera

A document camera can be used for showing text, diagrams and a variety of graphical material as well as small three-dimensional objects. How to use a document camera with your system:

1. Connect the document camera to the Doc Cam input, if available, on the system. 2. Open the Presentation menu from Main menu and choose Doc Cam. 3. You can also program the Presentation key on the remote to activate document camera. See chapter Presentation Key for more information. If you want to use S-Video from the document camera, you can connect the document camera to the AUX input on the system.
TANDBERG Edge MXP — 5.2 Document Camera diagram (page 243)
Fig. 110 · 5.2 Document Camera

Peripheral Equipment

Page 244 of the TANDBERG Edge MXP user manual — 5.3 DVD / VCR
Page 244 · click to enlarge
Page 244

5.3 DVD / VCR

DVD/VCR Playback Mono For playback, connect a cable between Video Out on the VCR and Video In (VCR) on the system. Connect a cable between Audio Out on the VCR and the Audio In (VCR) on the system. Choose VCR from the Presentation menu to activate the VCR input. Make sure that Audio In (VCR) is On (see chapter Audio). If audio from VCR is too low, this level can be adjusted in Audio Settings, Inputs and Level Settings. The audio from the VCR will be audible in the local speaker system. The audio from the VCR and your microphone(s) will be mixed and sent to the far end. When a person talks on either local or far end, the VCR audio level will be reduced to make it easier to comment on a video recording when Audio Settings, VCR Ducking: On. DVD/VCR Recording When recording a conference in stereo, the VCR will record the video as it appears on the main monitor, the local audio and the remote audio. It will record the conference in stereo if stereo audio is used in the conference. When recording a videoconference, connect a cable between Video Out 2 on the system and Video In on the VCR. Connect a cable between Audio Out 2 on the system and Audio In on the VCR. For stereo recording, connect:

ƒ Video cable between Video Out 2 on the system to Video In on the VCR ƒ Audio cable between Audio Out 2 (VCR L) to VCR/DVD Audio In (L) ƒ Audio cable between Audio Out 3 (VCR R) to VCR/DVD Audio In (R) Make sure that:

ƒ That Stereo I/O Mode is set to On ƒ 128 AAC-LD is enabled ƒ That AAC-LD is enabled ƒ To enable VCR/DVD ducking (reduce volume when speaking), check that VCR Ducking under Audio Settings is set to On. When recording, the VCR will record the video as it appears on the main monitor, the local audio and the audio from the far end.

Page 245 of the TANDBERG Edge MXP user manual — 5.4 Additional Cameras
Page 245 · click to enlarge
Page 245

5.4 Additional Cameras

Extra fixed Cameras You can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available Video inputs on the system.

Multiple controllable Cameras Attaching multiple cameras to one system expands visibility and is useful in large group applications. The system is able to control up to 4 WAVE II -cameras. Optional WAVE II cameras are supplied with the necessary cabling. In addition, an external power supply for the camera is included. WAVE II -camera number two must be connected to video input 2. Camera number three must be connected to video input 3, and so forth. The maximum length of the camera cable for multiple cameras supported by TANDBERG is 20 m (65 ft).

Peripheral Equipment

Page 246 of the TANDBERG Edge MXP user manual — 5.5 Additional Microphones
Page 246 · click to enlarge
Page 246

5.5 Additional Microphones

If your environment is such that you require more than one microphone for your room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See Appendix 4 for more information.

You can connect up to three additional microphones to your system for a total of 4 microphones. The connectors are marked Mic1, Mic2, Mic3 (Mic 1-3 XLR) and 4 (RCA Input). The connected microphones will by default be mixed. When more than one microphone is connected, you have the option to use the Voice Activate Camera Tracking feature. Audio Science Microphone TANDBERG's award-winning Audio Science microphone is a ceiling-mounted, wide coverage, boundary microphone, which can eliminate the need for table microphones. It is designed to pick up the audio from all conference participants seated within in its pick-up area, defined by a quarter-sphere of approximately 14-foot (4.25m) radius extended in front of, and to the sides of the microphone. Please contact your TANDBERG representative for further information.

Page 247 of the TANDBERG Edge MXP user manual — 5.5 Additional Microphones
Page 247 · click to enlarge
Page 247
TANDBERG Edge MXP — 5.5 Additional Microphones diagram (page 247)
Fig. 111 · 5.5 Additional Microphones

Peripheral Equipment

Page 248 of the TANDBERG Edge MXP user manual — 5.6 The TANDBERG DNAM and Speakers
Page 248 · click to enlarge
Page 248

5.6 The TANDBERG DNAM and Speakers

TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestro

The TANDBERG Digital Natural Audio Module, DNAM*:

The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.

TANDBERG Edge MXP — 5.6 The TANDBERG DNAM and Speakers diagram (page 248)
Fig. 112 · 5.6 The TANDBERG DNAM and Speakers
TANDBERG Edge MXP — 5.6 The TANDBERG DNAM and Speakers diagram (page 248)
Fig. 113 · 5.6 The TANDBERG DNAM and Speakers

TANDBERG 6000 MXP DNAM configuration

TANDBERG Edge MXP — 5.6 The TANDBERG DNAM and Speakers diagram (page 248)
Fig. 114 · 5.6 The TANDBERG DNAM and Speakers

TANDBERG 8000 MXP DNAM configuration

TANDBERG 7000 MXP DNAM configuration

Page 249 of the TANDBERG Edge MXP user manual — 5.6 The TANDBERG DNAM and Speakers
Page 249 · click to enlarge
Page 249
TANDBERG Edge MXP — 5.6 The TANDBERG DNAM and Speakers diagram (page 249)
Fig. 115 · 5.6 The TANDBERG DNAM and Speakers

TANDBERG 6000 MXP Profile DNAM configuration Center Speakers + Integrated Stereo Speakers

The DNAM Amplifier*:

ƒ 3 x 50W continuous average Center Output Power (load specified by DNAM Center Speakers). ƒ 2 x 50W continuous average Stereo Output Power (load specified by TANDBERG Loudspeaker Stereo Kit). ƒ Full dynamic range for audio (high fidelity range) ƒ Digital Signal Processing and Filtering on all channels for best audio detail clarity ƒ Digital Crossover Filtering on center channels. ƒ In/out:

ƒ Audio In - S/PDIF (stereo) or Analog (mono), using the same connector. ƒ Differential In - (female XLR pinout: 1 - GND, 2 – Signal (+), 3 – Signal (-)) ƒ Loop Out - line out directly from the input, always analog even with S/PDIF in. ƒ Stereo Out - (male XLR, common GND configuration) ƒ Fuse 2A 250V Slow, 5 x 20mm, Littelfuse type 215002.

TANDBERG Edge MXP — 5.6 The TANDBERG DNAM and Speakers diagram (page 249)
Fig. 116 · 5.6 The TANDBERG DNAM and Speakers

Peripheral Equipment

Page 250 of the TANDBERG Edge MXP user manual — TANDBERG 3000 MXP Profile:
Page 250 · click to enlarge
Page 250

The DNAM Loudspeaker Cabinet (Center Speakers)*:

ƒ 3-way Center Speaker system ƒ Frequency range 50Hz - 20kHz ƒ 2 x 130mm low- and midrange loudspeakers, 8 ohms nominal, high quality ƒ 1 x 25mm dome tweeter, 6 ohms nominal, high quality ƒ Crossover filtered audio signals received from DNAM amplifier ƒ Long time max power 90 Watt on all loudspeakers ƒ Enclosed MDF speaker cabinet Integrated Stereo Speakers**:

ƒ 2 * 15W Stereo Speakers, high quality ƒ Frequency range 100Hz - 20kHz ƒ Enclosed MDF speaker cabinet

Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.

Please refer to the section Stereo Speaker Kit for details.

TANDBERG 3000 MXP Profile:

The TANDBERG Mini-DNAM*:

The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini- DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.

The Mini-DNAM amplifier*The Mini-DNAM amplifier specification:
TANDBERG Edge MXP — TANDBERG 3000 MXP Profile: diagram (page 250)
Fig. 117 · TANDBERG 3000 MXP Profile:

ƒ Stereo digital SPDIF input ƒ 2x30W into 8ohm ƒ External DC power supply ƒ Compact size

Page 251 of the TANDBERG Edge MXP user manual — Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.
Page 251 · click to enlarge
Page 251
The Mini-DNAM Loudspeaker Cabinet*The Mini-DNAM speaker cabinet specification:
TANDBERG Edge MXP — Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system. diagram (page 251)
Fig. 118 · Using the external and optional Stereo Speaker Kit w…

ƒ 2 * 15W Stereo Speakers, high quality ƒ Frequency range 100Hz - 20kHz ƒ Enclosed MDF speaker cabinet

Integrated Stereo Speakers**:

ƒ 2 * 15W Stereo Speakers, high quality ƒ Frequency range 100Hz - 20kHz ƒ Enclosed MDF speaker cabinet *Note that there are different solutions on integrated audio modules and speakers included in the larger high-end TANDBERG systems. Please contact your TANDBERG representative for more information. ** These are available with the TANDBERG 3000 MXP Profile and TANDBERG 6000 MXP Profile only.

Peripheral Equipment

Page 252 of the TANDBERG Edge MXP user manual — 5.7 Stereo Speaker Kit
Page 252 · click to enlarge
Page 252

5.7 Stereo Speaker Kit

The Stereo Speaker Kit provides an pair of floor-standing loudspeakers in addition to the built-in DNAM. Using these speakers will enable stereo functionality in your system and thereby enhance the sound experience. To experience stereo sound, the stereo speakers have to be connected to the Digital Natural Audio Module (DNAM) as well as confirming this under Stereo Settings in the main audio menu. The stereo sound source may either be located at the far end, or locally as a sound source (CD, DVD) connected to the codec audio AUX/VCR inputs. If using a local stereo sound source, you also have to enable Stereo I/O mode (On) in the same audio menu, to be able to receive stereo sound on your system, and to send stereo signals to the far end. See chapter 4.5.4 for more information. Check also that the full-range frequency audio coding AAC-LD is enabled (In Call Quality menu, AAC-LD is checked, and AAC-LD 128 threshold is the same or lower than the call rate you are planning to use). See chapter Audio Algorithm and AAC-LD 128kbps for more information. An installation sheet is enclosed in the Stereo Loudspeaker Kit, which also describes recommended physical speaker placement. Make sure the complete videoconferencing system is powered down before connecting the Stereo Speaker Kit. Note that if stereo speakers are enabled in the menu without having any stereo speakers connected to the Digital NAM, or having other speakers than the TANDBERG stereo speakers, it may cause the acoustic echo-canceller to malfunction.

Stereo Speaker Kit specification:

ƒ 2-way Stereo Speaker system (dual speakers in low- and midrange) ƒ Passive Crossover Filtering. ƒ Frequency range 50Hz - 20kHz ƒ 2 x 130mm low- and midrange loudspeakers, 8 ohms nominal, high quality. ƒ 1 x 25mm dome tweeter, 6 ohms nominal, high quality ƒ Long time max power 90 Watt on all loudspeakers ƒ Enclosed aluminum speaker cabinet

Page 253 of the TANDBERG Edge MXP user manual — 5.7 Stereo Speaker Kit
Page 253 · click to enlarge
Page 253
TANDBERG Edge MXP — 5.7 Stereo Speaker Kit diagram (page 253)
Fig. 119 · 5.7 Stereo Speaker Kit

Peripheral Equipment

Page 254 of the TANDBERG Edge MXP user manual — 5.8 Telephone Add-On
Page 254 · click to enlarge
Page 254

5.8 Telephone Add-On

The system has a built in audio bridge* that can bring in Voice over IP (VoIP) telephony or normal telephone sites using ISDN.

In addition to using ISDN and IP for your telephone sites, it is possible to connect a telephone using normal POTS line** by

ƒ Connect the audio out from the conference telephone to the AUX input. ƒ Connect the audio input from the conference telephone to the AUX output, which provides a mixed signal between local and far end. *optional MultiSite package available ** require a conference phone with external audio input and output

Page 255 of the TANDBERG Edge MXP user manual — 5.9 Dual Monitor
Page 255 · click to enlarge
Page 255

5.9 Dual Monitor

The Dual Monitor option consists of an additional monitor, bigger cabinet top-plate and associated cabling. The Dual Monitor can be used to show full screen selfview, snapshots and Duo Video. To use the system in the Dual Monitor configuration:

1. Connect Video Out 2 (preferably) otherwise Video Out 4 on the system to a video input on the dual monitor. 2. Set Dual Monitor to On in the General Settings menu.

Peripheral Equipment

Page 256 of the TANDBERG Edge MXP user manual — 5.10 XGA Monitors and Projectors
Page 256 · click to enlarge
Page 256

5.10 XGA Monitors and Projectors

(Optional) Some TANDBERG systems can be delivered with optional single or dual TV/XGA monitors. It can also be connected to any DVI/VGA/PAL or NTSC display.

Page 257 of the TANDBERG Edge MXP user manual — 5.11 VESA Display Power Management
Page 257 · click to enlarge
Page 257

5.11 VESA Display Power Management

Because of the tremendous amount of energy consumed by monitors when operating, the system will reduce power consumption and extend monitor lifecycle by suspending the (switch off) monitors and projectors when the system goes into sleep/standby. This applies for all VESA Display Power Management compliant displays that are connected to the VGA/DVI output of the system. The display device needs to comply with VESA display Power Management system (DPMS).

The VESA DPMS standard consists of four modes, Normal, Standby, Suspend and Off, and applies to all Sync formats (e.g. VGA). DPMS standard:

TANDBERG Edge MXP — 5.11 VESA Display Power Management diagram (page 257)
Fig. 120 · 5.11 VESA Display Power Management

Recovery time None 2-3 seconds 2-3 seconds 8-10 seconds

In Off mode some power may still be drawn in order to power indicator lights etc. EDID contains the information on which mode a specific monitor supports. TANDBERG supports all four modes. However, in F1 and above, all monitors not listed below are automatically set to Off.

TANDBERG Edge MXP — 5.11 VESA Display Power Management diagram (page 257)
Fig. 121 · 5.11 VESA Display Power Management

Peripheral Equipment

Page 258 of the TANDBERG Edge MXP user manual — 5.12 Digital Monitor Power Management
Page 258 · click to enlarge
Page 258

5.12 Digital Monitor Power Management

DMPM is monitor power management applied over the digital DVI interface. TANDBERG supports DMPM in software F2 and above. Six monitor power states are defined. Monitor On Power state Transmitter (TANDBERG codec) and receiver (Monitor) are powered and active. This power state is equivalent with the DPMS normal mode. Intermediate Power state When the codec goes from active to standby, it turns off the DVI transmitter and the monitor can go from Monitor On Power state to Intermediate Power state Active-off Power state The monitor can go from Intermediate Power state to Active-off Power state when the monitor timer expires. Non-Link Recoverable Off Power State The monitor can enter Non-Link Recoverable Off Power State when the codec is switched off or if the DVI cable is disconnected. This power state is equivalent to the DPMS “Off (with no DPMS recovery)” state. Monitor Power Switch Off Power state This state can be entered when the power switch on the monitor is toggled to its off position. This state has two sub-states dependent on if the codec is switched on or off.

Page 259 of the TANDBERG Edge MXP user manual — 5.13 Extended Display Identification Data (EDID)
Page 259 · click to enlarge
Page 259

5.13 Extended Display Identification Data (EDID)

Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its capabilities, including vendor information like the supported VGA- formats and frequency range limits to a PC connected to the XGA/DVI input.

This means that the PC always* will be able to output a valid VGA/DVI signal to the system with no manual reconfiguration of the PC screen settings. TANDBERG supports EDID structure v1.3, which adheres to the MS Plug & Play definition. This standard contains information on product ID, basic display parameters, timing identifications and detailed timing descriptions. In F1 and above, TANDBERG will use the EDID information to decide which resolution to use, 800x600 @ 75Hz or 1024x768 @ 60Hz.

TANDBERG Edge MXP — 5.13 Extended Display Identification Data (EDID) diagram (page 259)
Fig. 122 · 5.13 Extended Display Identification Data (EDID)

Peripheral Equipment

Page 260 of the TANDBERG Edge MXP user manual — 5.13 Extended Display Identification Data (EDID)
Page 260 · click to enlarge
Page 260

Tested and verified monitors, EDID & Timing Listed below are some of the monitors TANDBERG have tested and verified against:

ADI A715 Dell W1700 Dell W1900 EIZO L367 EIZO F730 ErgoScan 400S Hitachi CM640ET Hitachi CM769ET IBM 9494-HBO IBM G97 IBM E74 IBM 6743-60N JVC LT-23X475 JVC LT-23C50BU JVC LT-23X576 LG L3200A LG M3200C Löewe TAA112747 MAG D700 MAG DJ707 Panasonic SL75 Pioneer PDP-50MXE10 Pioneer PDP-42MXE10-S Pioneer PDP-43MXE1-S Pioneer PDP-50MXE11 Samsung 191T Samsung 323T

*Need to comply with the VESA EDID standard.

Page 261 of the TANDBERG Edge MXP user manual — 6 Appendices
Page 261 · click to enlarge
Page 261

6 Appendices

Appendices:

ƒ Appendix 1: Technical Specification ƒ Appendix 2: Bandwidth Information ƒ Appendix 3: Environmental considerations ƒ Appendix 4: Guidelines for setting up videoconferencing rooms ƒ Appendix 5: Security ƒ Appendix 6: Using the file system ƒ Appendix 7: Web Interface ƒ Appendix 8: Connecting the system to PRI/T1 ƒ Appendix 9: Connecting the system to the Switched 56 network ƒ Appendix 10: Connecting the system to ISDN using NT1 network adapters ƒ Appendix 11: Wave II Camera Pinouts and Connectors ƒ Appendix 12: Remote control ƒ Appendix 13: CallManager registration ƒ Appendix 14: Diagnostic Tools for IP ƒ Appendix 15: System Upgrade ƒ Appendix 16: Declaration of Conformity

Page 262 of the TANDBERG Edge MXP user manual — 6.1 Appendix 1
Page 262 · click to enlarge
Page 262

6.1 Appendix 1

Technical Specification

SYSTEM COMPONENTS Integrated 5" LCD display, WAVE II camera, microphone, Digital Natural Audio Module (DNAM), integrated cabling, cart BANDWIDTH H.320 up to 2 Mbps H.323 up to 4 Mbps point-to-point SIP up to 4 Mbps Up to 6Mbps total MultiSite bandwidth FIREWALL TRAVERSAL TANDBERG Expressway TechnologyTM Auto NAT VIDEO STANDARDS H.261, H.263, H.263+, H.263++ (Natural Video), H.264 VIDEO FEATURES Native 16:9 Widescreen Advanced Screen Layouts Picture in Picture (PIP) Picture outside Picture (POP) Side by Side PC Zoom Intelligent Video Management Simultaneous videoconference & local PC mode VIDEO INPUTS (5 INPUTS) 1 x MiniDin, S-video: main camera 1 x MiniDin, S-video: auxiliary / document camera 1 x RCA / Phono, composite: document camera / aux 1 x RCA / Phono, composite: VCR 1 x DVI/SXGA: PC Input: 800 x 600 (@ 60, 72, 75, 85 Hz), 1024 x 768 (@ 60, 70, 75 Hz), 1280 x 1024 @ 60Hz Extended Display Identification Data (EDID) VIDEO OUTPUTS (6 OUTPUTS) 1 x MiniDin, S-video: main monitor 1 x MiniDin, S-video: dual monitor 1 x RCA / Phono, composite: main monitor or VCR 1 x RCA / Phono, composite: dual monitor or VCR 2 x DVI/XGA: main and dual monitor XGA OUTPUT 800 x 600 @ 75 Hz, 1024 x 768 @ 60 Hz, 1280 x 768 (WXGA) @ 60 Hz VESA Monitor Power Management VIDEO FORMAT NTSC, PAL, VGA, SVGA, XGA or SXGA LIVE VIDEO RESOLUTIONS NATIVE NTSC: 4SIF (704 x 480 pixels), Digital Clarity

EMBEDDED ENCRYPTION H.320 and H.323 point-to-point and multipoint calls Standards-based: H.233, H.234, H.235 v2&v3, DES and AES NIST-validated AES NIST-validated DES Automatic key generation and exchange Supported in Dual Stream and Multisite IP NETWORK FEATURES H.235 Authentication Differentiated Services (DiffServ) Resource Reservation Protocol (RSVP) IP precedence IP type of service (ToS) IP adaptive bandwidth management (including flow control) Auto gatekeeper discovery Dynamic playout and lip-sync buffering Intelligent Packet Loss Recovery (IPLR) H.245 DTMF tones in H.323 Cisco Call Manager integration using ECS IP Address Conflict Warning SECURITY FEATURES Management via HTTPS IP Administration Password Menu Administration Password Dialing Access code Streaming password H243 MCU Password VNC password SNMP security alerts Disable IP services MD-5 Challenge Network Settings protection SIP Authentication via NTLM and Digest Authentication IEEE 802.1x NETWORK INTERFACES 6 x ISDN BRI (RJ-45), S-inter face 1 x E1 / T1 G.703 (RJ-45) for ISDN PRI or Leased E1 / T1 1 x E1 / T1 G.703 (RJ-45) for future usage 1 x LAN / Ethernet (RJ-45) 10/100 Mbit (LAN / DSL / cable modem) 1 x X.21 / V.35 / RS-449 with RS-366 dialing or Leased Line 1 x USB (for future use) ETHERNET / INTERNET / INTRANET CONNECTIVITY TCP / IP, DHCP, ARP, FTP, Telnet, HTTP, HTTPS, SOAP and XML SNMP Enterprise Management Internal web server

Page 263 of the TANDBERG Edge MXP user manual — 6.1 Appendix 1
Page 263 · click to enlarge
Page 263

Interlaced SIF (352 x 480 pixels), Natural Video SIF (352 x 240 pixels) 400p (528 x 400 pixels) NATIVE PAL: 4CIF (704 x 576 pixels), Digital Clarity Interlaced CIF (352 x 576 pixels), Natural Video CIF (352 x 288 pixels) QCIF (176 x 144 pixels) SQCIF (128 x 96 pixels) decode only 448p (576 x 448 pixels) NATIVE PC RESOLUTIONS: XGA (1024 x 768) SVGA (800 x 600 pixels) VGA (640 x 480 pixels) WIDE (16:9) RESOLUTIONS: w288p (512 x 288 pixels) w448p (768 x 448 pixels) w576p (1024 x 576 pixels) w720p (1280 x 720 pixels) STILL IMAGE TRANSFER CIF, SIF, 4CIF (H.261 Annex D), 4SIF, VGA, SVGA, XGA AUDIO STANDARDS G.711, G.722, G.722.1, G.728 , 64 bit & 128 bit MPEG4 AAC-LD AUDIO FEATURES CD-Quality 20KHz Mono and Stereo Telephone add-on via MultiSite Four separate acoustic echo cancellers Audio mixer Automatic Gain Control (AGC) Automatic Noise Reduction Audio level meters VCR ducking Optional Stereo Package Packet loss management Active lip synchronization GSM / Blackberry noise filter AUDIO INPUTS (6 INPUTS) 3 x microphone, 24V phantom powered, XLR connector 1 x RCA / Phono, Line Level: audio mixer 1 x RCA / Phono, Line Level: auxiliary (or VCR/DVD Stereo L) 1 x RCA / Phono, Line Level: VCR/DVD (Stereo R) AUDIO OUTPUTS (3 OUTPUTS) 1 x RCA / Phono, S/PDIF (mono/stereo) or Analogue Line Level: main audio 1 x RCA / Phono, Line Level: auxiliar y (or VCR Stereo L) 1 x RCA / Phono, Line Level: VCR (Stereo R) FRAME RATES 30 frames per second @ 168 kbps and above 60 fields per second @ 336 kbps and above (Point-to- point) DUAL STREAM Duo Video & H.239 Available on H.323 & H.320 Available in MultiSite from any site NETWORK FEATURES Auto H.320 / H.323 dialing SIP

Internal streaming server OTHER MAJOR ITU STANDARDS SUPPORTED H.231, H.233, H.234, H.235 v2&v3, H.239, H.241, H.243, H.281, BONDING (ISO 13871), H.320, H.323, H.331 RFC 3261, RFC 2237, RFC 3264, RC 3311, RFC 3550, RFC 2032, RFC 2190, RFC 2429, RFC 3407, H.460.18, H.460.19 W.A.V.E. (WIDE ANGLE VIEW) II CAMERA 10 x zoom 1/4" CCD +15° / -20° tilt + / -95°pan 61° vertical field of view 96° total vertical field of view 77° horizontal field of view 267° total horizontal field of view 460 (PAL) / 470 (NTSC) TV lines Min. illumination 2 Lux (F1.8) Auto or manual focus / brightness / white balance Far-end camera control 15 near and far-end camera pre-sets Voice-activated camera positioning Daisy chain support for up to 4 cameras VISCA camera support CLOSED CAPTIONING/TEXT CHAT T.140 text chat available from RS-232, Telnet, Web and User Interface PRESENTATIONS AND COLLABORATION Natural Presenter Package including: PC Presenter (DVI-I, SXGA In) PC SoftPresenter Digital Clarity & Native Formats Advanced Video Layouts Streaming compatible with Cisco IP/TV, Apple QuickTime®, RealPlayer® v8 etc. SYSTEM MANAGEMENT Support for the TANDBERG Management Suite Total management via embedded web server, SNMP, Telnet, XML, SOAP and FTP Remote software upload :via web server or FTP server 1 x RS-232 local control and diagnostics Remote control and on-screen menu system DIRECTORY SERVICES Support for Local, Global and Dynamic Server Directories Unlimited entries using Server directory* supporting LDAP and H.350 400 number global directory 200 number local directory 50 dedicated MultiSite entries Last Number Dialed, Missed Calls, Call History Directories in Local Languages 16 SELECTABLE MENU LANGUAGES English, German, French, Norwegian, Swedish, Italian, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Japanese, Russian, Korean, Finnish, Thai and Arabic CUSTOMIZED WELCOME SCREEN AND COMPANY LOGO POWER Auto-sensing power supply

Glossary

Page 264 of the TANDBERG Edge MXP user manual — 6.1 Appendix 1
Page 264 · click to enlarge
Page 264

Downspeeding Programmable network profiles Intelligent Call Management HO on ISDN-PRI Facility Maximum call length timer Automatic SPID and line number configuration (National ISDN, GR-2941-CORE) SoftMux NATO standard KG194 / KIV-7 encryptor support H.331 Broadcast Mode URI Dialing IP version 6 MULTISITE FEATURES H.323/H.320/SIP/Telephony/VoIP in the same conference Audio and Video Transcoding Video rate matching from 56 kbps - maximum conference rate CP4, CP 5 + 1 and Voice Switched Best Impression (Automatic CP Layouts) H.264, Encryption, Digital Clarity Dual Stream from any site ISDN & IP Downspeeding and IPLR MultiSite (H.243) Cascading on H.320 & H.323 Dial in / Dial out Chair control for host system Snapshot of ongoing conference (JPEG) Snapshot of ongoing Dual Stream presentation (JPEG) Separate welcome page for encrypted conferences Conference rates up to 6 Mbps Up to 6 video and 5 audio sites 4 sites @ 2 Mbps, 6 sites @ 768 (+telephone calls) Mix ISDN (BRI or PRI), or Serial Inter face (V.35) with IP up to maximum conference rate

100 - 250 VAC, 50 - 60 Hz 65 watts max for codec and camera 250 watts for DNAM 50 watts integrated LCD display OPERATING TEMPERATURE AND HUMIDITY 0° C to 35° C (32° F to 95° F) ambient temperature. 10% to 90 % Relative Humidity (RH) STORAGE AND TRANSPORT TEMPERATURE -20° C to 60° C (-4° F to 140° F) at RH 10-90 % (non- condensing) APPROVALS Directive 73/23/EEC (Low Voltage Directive) -Standard EN 60950 Directive 89/336/EEC (EMC Directive) -Standard EN 55022, Class B -Standard EN 55024 -Standard EN 61000-3-2/-3-3 Directive 1999/5/EEC (R&TTE Directive) -Standard TBR3 -Standard TBR4 Approved according to UL 60950 and CAN/CSA C22.2 No. 60950 Complies with FCC15B Class B DIMENSIONS Width : 649 mm Depth : 707 mm Height : 1460 mm Weight : 31 kg

PRODUCT RELIABILITY / MTBF The predicted reliability is expressed in the expected random Mean Time Between Failures (MTBF) for the electronic components based on the Power On Hours: Power On Hours (POH) > 69 000 hours Useful Life Cycle > 6 years ISO 9001 certificate is available upon request * Requires TANDBERG Management Suite 9.0 or newer System features vary depending on network selection and software package. All specifications are subject to change without notice. TANDBERG is a registered trademark or trademark of TANDBERG in the U.S. and other countries. RealPlayer is a trademark or a registered trademark of RealNetworks, Inc. QuickTime is a registered trademark of Apple Computer, Inc., registered in the U.S. and other countries. Microsoft and NetMeeting are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other trademarks are property of their respective owners. Contains iTypeTM from Agfa Monotype Corporation Service availability may vary from region to region. Please contact your TANDBERG reseller for more information.

Page 265 of the TANDBERG Edge MXP user manual — 2000MXP, 1500MXP
Page 265 · click to enlarge
Page 265

6.2 Appendix 2

Bandwidth information for TANDBERG endpoints

Model 8000MXP, 7000MXP 6000MXP, Maestro

Bandwidth Point to point ISDN / IP

Standard768 / 3072 Option: 1920 / 4096
Standard768 / 3072 Option: 1920 / 4096

MultiSite Total: 3072kbps 4x768 video + 4 audio 3x1536 video + no audio Total: 6144kbps 6x1152 video + 5 audio 5x1536 video + no audio 4x1920 video + 5 audio 3x3072 video + no audio

Total: 3072kbps 4x768 video + 4 audio 3x1536 video + no audio Total: 6144kbps 6x1152 video + 5 audio 5x1536 video + no audio 4x1920 video + 5 audio 3x3072 video + no audio

Dual Stream (DuoVideo / H.239)

All bandwidths All bandwidths

H.264 Up to 2Mbps Up to 2Mbps

VS, CP4, CP5+1 VS, CP4, CP5+1

Model 3000MXP / 3000NET MXP

2000MXP, 1500MXP

Bandwidth Point to point ISDN / IP

Standard384 / 1536 Option: 512 / 1920 3000NET: 384 / 1536
Standard1920 (IP only) Options: 512 / 1920
MultiSite Total1536kbps 4x512 video + no audio 4x384 video + 3 audio Total: 2304kbps
Total2304kbps 4x768 video + no audio 4x512 video + 3 audio
Show 6 more labels / short text on this page
Glossary · Rate Matching · Yes Yes · Yes Yes · Secure Conference · Picture Mode MultiSite
Page 266 of the TANDBERG Edge MXP user manual — 6.2 Appendix 2
Page 266 · click to enlarge
Page 266
TANDBERG Edge MXP — 6.2 Appendix 2 diagram (page 266)
Fig. 123 · 6.2 Appendix 2

4x768 video + no audio 4x512 video + 3 audio

Standard1920 (IP only) Options: 512 / 1920 990NET: 768 / 1920
MultiSite Total2304kbps 4x768 video + no audio 4x512 video + 3 audio
Total1152kbps 4x384 video + no audio 4x320 video + 3 audio
Page 267 of the TANDBERG Edge MXP user manual — 6.2 Appendix 2
Page 267 · click to enlarge
Page 267
TANDBERG Edge MXP — 6.2 Appendix 2 diagram (page 267)
Fig. 124 · 6.2 Appendix 2
Standard768 (IP only) Options: 128 / 768, 384 / 768
Standard768 (IP only) Options: 128 / 768, 384 / 768

Glossary

Page 268 of the TANDBERG Edge MXP user manual — 6.3 Appendix 3
Page 268 · click to enlarge
Page 268

6.3 Appendix 3

Environmental considerations This section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting By default the system camera will use an automatic iris to compensate for changes in lighting. In addition to this feature, you may further assist the system to maintain the best possible image quality by paying special attention to environmental lighting and background colors as described below. Remember the system will send live images of yourself and your immediate surroundings.

ƒ Avoid direct sunlight on the subject matter i.e. yourself, the background or onto the camera lens as this will create harsh contrasts. ƒ If light levels are too low you may need to consider using artificial lighting. As described above, direct illumination of the subject matter and camera lens should be avoided. ƒ When using artificial lighting, daylight type lamps will produce the most effective results. Avoid colored lighting. ƒ Indirect light from shaded sources or reflected light from pale walls often produces excellent results. ƒ Avoid harsh side lighting or strong light from above. Strong sunlight from a window or skylight may put part or all of the subject matter in shadow or cause silhouetting. ƒ If you still have problems with the iris and lighting, manual adjustment of the camera parameters might help – see Video Settings menu. ƒ Dim scenes can also be improved by manually adjusting the camera brightness setting. Background The appearance of the picture background is very important but easily overlooked. It is important to remember that the camera also shows what is behind you when in a videoconference. To ensure a suitable background we recommend you consider the following:

ƒ Use a neutrally colored background with a medium contrast and a soft texture, e.g. a plain curtain with no heavy patterns or strong colors that may adversely tint the whole scene. ƒ Avoid moving backgrounds such as curtains blowing in a draught, moving objects, or people walking behind as this may both reduce image quality and distract the attention of the calling party. ƒ Do not place the camera facing a doorway. Loudspeaker volume The audio system will use the Digital Natural Audio Module (DNAM) if available and supported by the system. The volume of the audio system is controlled by the Volume Control keys on the system remote control.

Page 269 of the TANDBERG Edge MXP user manual — 6.4 Appendix 4
Page 269 · click to enlarge
Page 269

6.4 Appendix 4

Guidelines for setting up videoconferencing rooms The following are a set of guidelines to consider when either building a videoconferencing room, or using an existing room for videoconferencing.

Lighting:

Audio:

ƒ Low Contrast desired for light intensity. No dark spots. ƒ Intensity @ table 800 - 1400 Lux as measured with an Incident light meter. ƒ Block sunlight from entering room. Seating Area (Table):

ƒ Noise Floor preferred less than 44dBC. ƒ Reverb Time 0,3 to 0,5 sec. Ventilation:

ƒ Keep in mind Noise Floor. ƒ Velocity = Noise. Therefore keep velocity of air low. Room:

ƒ Should allow all participants to see Monitors. ƒ Should allow camera to “see” all participants. ƒ Non-shiny non-patterned preferably light grey surface (if table used). Walls:

ƒ Should be located away from noise. ƒ Should not have windows. ƒ Doors should be located off camera.

ƒ Color: Generally high contrast color desired. Light blue is commonly used. ƒ Acoustically reflective surfaces (such as glass or concrete) should be covered with curtains or sound treatment.

When a front projector is used to display video images, it is important to place the camera outside the projected light area, position the camera close to one side of the projector screen. To avoid disturbance from the projectors light, ceiling mounting of projector gives the best solution.

Glossary

Page 270 of the TANDBERG Edge MXP user manual — 1234 1250 A1 B2 ABC
Page 270 · click to enlarge
Page 270

6.5 Appendix 5

Security The system has several features both to protect from unauthorized use and system access: Access Code: When Access Code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the entered access code is valid by checking the code with the allowed codes listed in the access.txt file on the ftp-server in the system. If no access.txt file is uploaded to the system, registration of the code will be done without validation. E.g. you can enter whatever code you want and have access to the system. The access.txt file is a plain text file with one line per access code as shown below:

1234 1250 A1 B2 ABC

To upload this file to the system, follow these steps:

ƒ Open a DOS-window and go to the folder where the ‘access.txt’ file is located. ƒ Type ftp

Page 271 of the TANDBERG Edge MXP user manual — 6.5 Appendix 5
Page 271 · click to enlarge
Page 271

By setting an IP Access Password on the system, all access to the system using IP (Telnet, FTP and WEB) requires a password. This password can be enabled from telnet or dataport using the command: ippassword . The default IP username and password is "TANDBERG". To remove this password, use the command: "ippassword ”. From telnet, this is only possible by first entering the correct password. IP Services The different IP services on the system - FTP, Telnet, Telnet Challenge, HTTP, HTTPS, SNMP and H.323 can be disabled to prevent access to the system. By using the commands below, the services can be independently enabled/disabled: xconfiguration Telnet/TelnetChallenge/FTP/HTTP/HTTPS/H323 Mode: xconfiguration TelnetChallenge Mode: [port] xconfiguration SNMP Mode: SNMP Security alert This function will notify any Management Application (such as TMS - TANDBERG Management Suite) if anyone tries to perform Remote Management on the system using an illegal password. The Security alert that is sent to the Management Application will contain information about the IP address and the service (WEB, Telnet, FTP) being used for the attempt. If TMS is used, email notifications or alarms about the attempt can be sent to specified persons. Encryption All TANDBERG systems support both AES and DES encryption. By default this feature is enabled such that when connecting with any other video system or MCU, a TANDBERG system will attempt to establish a secure conference using AES or DES encryption. The TANDBERG system will attempt this for both IP and ISDN connections. Where a remote system or MCU supports encryption, the highest common encryption algorithm will be selected on a port-by-port basis. The type and status of the encryption negotiated is indicated by padlock symbols and on-screen messages. Encryption on the TANDBERG systems is fully automatic, and provides clear security status indicators;

ƒ An open padlock indicates that encryption is being initialized, but the conference is not yet encrypted. ƒ Single padlock indicates DES encryption. ƒ Double padlock indicates AES encryption. In addition to on-screen indicators the Call Status menu provides two information fields regarding call encryption. The first field is the Encryption Code, which will identify either AES or DES. The second field is the Encryption Check Code and is comprised of an alphanumeric string. This string will be the same for systems on either side of an encrypted conference. If the Check Codes do not match, this would indicate that the call has been exposed to a Man In The Middle attack. When a system with MultiSite functionality hosts a conference, the highest possible encryption algorithm will be negotiated on a site-by-site basis. MultiSite conferences can therefore support a mix of AES and DES encrypted endpoints in the same conference. A conference will only be as secure as its weakest link. All systems supporting DES encryption can upgrade to AES encryption. Please contact your TANDBERG representative for more information. The standards supporting the encryption mechanisms employed by TANDBERG are: AES, DES, H.233, H234 and H.235 (H235v3 & v2 for

Glossary

Page 272 of the TANDBERG Edge MXP user manual — 6.5 Appendix 5
Page 272 · click to enlarge
Page 272

backwards compatibility) with extended Diffie Hellman key distribution via H.320, H.323 and Leased Line connections. The TANDBERG AES implementation is validated as conforming to the Advanced Encryption Standard (AES) Algorithm, as specified in Federal Information Processing Standard Publication 197, Advanced Encryption Standard, by The National Institute of Standards and Technology (NIST). IEEE 802.1x / EAP (Extensible Authentication Protocol) This is a standard for authentication and authorization of units/systems onto the network. Static configuration

ƒ System ID and Password ƒ Anonymous ID for encryption challenge ƒ Enable methods Supported methods

ƒ MD5 (simple challenge) ƒ PEAP (encrypted channel) ƒ TTLS Note that 802.1x wireless LAN is not supported.

Page 273 of the TANDBERG Edge MXP user manual — 6.6 Appendix 6
Page 273 · click to enlarge
Page 273
Page 273 of the TANDBERG Edge MXP user manual — 6.6 Appendix 6
Page 274 of the TANDBERG Edge MXP user manual — 6.7 Appendix 7
Page 274 · click to enlarge
Page 274

6.7 Appendix 7

Web Interface It is possible to access and maintain the system remotely via a local area network (LAN) using a standard Web-browser. Connect your system to a LAN with a Network cable. How to configure your system for web interface:

1. Open Administrator Settings and choose Network\ LAN Settings 2. Specify IP-assignment DHCP or Static. If DHCP is selected, no other settings are needed. If Static is selected, IP-address, IP-subnet mask and Gateway must be specified. 3. Start your Web-browser. In the address field type the IP-address of the system. Enter the password and the Web-page of the system will be shown. The default password is TANDBERG. 4. Restart the system. Choose Restart from the Control Panel.
ExampleIP-assignment: Static IP-address: 196.9.200.129 IP-subnet mask: 255.255.255.0 Gateway: 196.9.200.21
Page 275 of the TANDBERG Edge MXP user manual — 6.8 Appendix 8
Page 275 · click to enlarge
Page 275

6.8 Appendix 8

(Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection. The E1/T1-interface must be connected to a CSU approved according to IEC 60950, UL 1950 or equivalent standard. The PRI- line will run the AT&T 4ESS, 5ESS and National ISDN protocols in addition to Euro ISDN (E1). Connecting to Adtran T1 ESF CSU ACE Connect the PRI cable from the system to the input marked CPE (Customer Provided Equipment) on the Adtran CSU (straight through category 5 cable is recommended). Connect to the network via the NET connector on the Adtran CSU. Configuration of the system Open the Administrator Settings Menu from the Control Panel and select Network. Choose Network Type: PRI and specify your PRI number, max. Channels, cable length (between system and CSU) and switch type. Configuration of Adtran T1 ESF CSU ACE

ƒ Enter 2)CONFIG menu using SCROLL and ENTER buttons. ƒ Enter 3)TERMINAL menu. Check 1)FORMAT:ESF, 2)CODE: B8ZS , 3)SET LBO: 0-133 (corresponding to Cable Length setting on the system). ƒ Go to main menu and enter 1)NETWORK menu. 7)SET LBO: 0.0 (according to information from Telco). ƒ Also, other network parameters should be set according to information from your Telco.

Glossary

Page 276 of the TANDBERG Edge MXP user manual — NUMBER1: NUMBER2: SPID1: SPID2:
Page 276 · click to enlarge
Page 276

6.9 Appendix 9

Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapter Connecting the system to the SW56 network using a Telesync Adapter is described below. There are different Telesync Adapters for different configurations of SW56 networks. The network types tested with the system are SW56 2Wire and 4Wire. Connecting Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect the two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network.

TANDBERG Edge MXP — 6.9 Appendix 9 diagram (page 276)
Fig. 125 · 6.9 Appendix 9

Configuration of the system Select network type to National ISDN. LINE 1 SETUP

NUMBER1: NUMBER2: SPID1: SPID2:

program with number from the first SW56 line program with number from the second SW56 line program with number from the first SW56 line Leave blank

How to call It is important to use Restrict (56k). Select Restrict (56k) in Call Settings in the Call menu (select the field next to the phone book button in the call menu). A second number field will appear when ISDN is selected for Net within Call Settings and you choose bandwidth 128 kbps. Enter the second number in the call settings menu.

Page 277 of the TANDBERG Edge MXP user manual — 6.10 Appendix 10
Page 277 · click to enlarge
Page 277

6.10 Appendix 10

Connecting the system to ISDN using NT1 network adapters

Connecting Connect the first ISDN cable from ISDN 1 on the system to the S-interface on your first NT1 network adapter. Connect the other ISDN cables to the appropriate NT1 network adapters. Connect the U-interface of your NT1 adapter to the line provided from your network provider. For convenience the NT1 adapters could be placed inside the cabinet. If needed, use the shorter ISDN cable (RJ45 connectors) delivered with the NT1 between the codec and the NT1 and the longer ISDN cable between the NT1 and the connector (RJ45) at the wall socket. Configuring The configuration of the system is performed in the same manner as described in ISDN BRI Settings. The NT1 should be powered up and you should check that the network is active. Please check your NT1 User Manual.

TANDBERG Edge MXP — 6.10 Appendix 10 diagram (page 277)
Fig. 126 · 6.10 Appendix 10

Glossary

Page 278 of the TANDBERG Edge MXP user manual — 6.11 Appendix 11
Page 278 · click to enlarge
Page 278

6.11 Appendix 11

(Not available with set top systems) WAVE II Camera Pinouts and Connectors 8-PIN RJ (shielded modular jack): This connector is used for the power and control signals to the main camera.

TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 278)
Fig. 127 · 6.11 Appendix 11

Pin-8 +12V (presence when connected in daisy chain)

Standard Phono: Used for composite video signal Power: 2.0 mm DC power jack (+12V, 1A required) Standard Mini Din: Used for S-Video signal

Show 7 more labels / short text on this page
Pin-7 GND · Pin-6 GND · Pin-5 RXD (in) · Pin-4 TXD (out) · Pin-3 +12V · Pin-2 GND · Pin-1 + 12V
Page 279 of the TANDBERG Edge MXP user manual — 6.11 Appendix 11
Page 279 · click to enlarge
Page 279

6-PIN RJ (modular jack): This connector is used when cascading cameras: Control (out) signal and external camera detection. Note: It does not provide power for cascaded camera.

Pin-2 Presence (+12V in daisy chain)

Multiple Camera supportThe figure below is an example of how multiple cameras should be connected:
TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 279)
Fig. 128 · 6.11 Appendix 11
TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 279)
Fig. 129 · 6.11 Appendix 11
TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 279)
Fig. 130 · 6.11 Appendix 11
Show 7 more labels / short text on this page
Glossary · PRI Pinout · Pin-6 GND · Pin-5 GND · Pin-4 RXD (in) · Pin-3 TXD (out) · Pin-1 GND
Page 280 of the TANDBERG Edge MXP user manual — 6.11 Appendix 11
Page 280 · click to enlarge
Page 280

Dimensions Front view:

Side view:

TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 280)
Fig. 131 · 6.11 Appendix 11
TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 280)
Fig. 132 · 6.11 Appendix 11

Rear view:

Underside view:

TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 280)
Fig. 133 · 6.11 Appendix 11
TANDBERG Edge MXP — 6.11 Appendix 11 diagram (page 280)
Fig. 134 · 6.11 Appendix 11
Page 281 of the TANDBERG Edge MXP user manual — 6.12 Appendix 12
Page 281 · click to enlarge
Page 281

6.12 Appendix 12

Remote Control (TRC 3 / TRC4) The TANDBERG remote control transmits IR-signals using the following parameters:

Address 4 & 7

IR carrier frequency 30kHz

Show 4 more labels / short text on this page
Glossary · Protocol Siemens SDA2208 · Reference frequency 485kHz · IR wavelength 940nm
Page 282 of the TANDBERG Edge MXP user manual — 6.12 Appendix 12
Page 282 · click to enlarge
Page 282

Remote Control keycode map:

TANDBERG Edge MXP — 6.12 Appendix 12 diagram (page 282)
Fig. 135 · 6.12 Appendix 12

1 01 0 NUMBER 1 34 22 0 CALL 0 CALL

2 02 0 NUMBER 2 35 23 0 END CALL

3 03 0 NUMBER 3 36 24 0 PHONE

4 04 0 NUMBER 4 37 25 0 MENU 0 MENU

5 05 0 NUMBER 5 38 26 0 CANCEL 0 CANCEL

6 06 0 NUMBER 6 39 27 0 0

7 07 0 NUMBER 7 40 28 0 LAYOUT 0 LAYOUT

9 09 0 NUMBER 9 42 2A 0 MAIN CAM

10 0A 0 NUMBER 0 43 2B 0 PC

11 0B 0 * 44 2C 0 DOC CAM

31 1F 0 LEFT 25 19 3 LOW BATT

Page 283 of the TANDBERG Edge MXP user manual — 6.13 Appendix 13
Page 283 · click to enlarge
Page 283

6.13 Appendix 13

Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 software and forward.

1. To configure the CallManager with an H.323 client, log on to the administration web interface and go to the phone configuration page. 2. The Phone configuration page is located on: device (top menu) -> Add a New device -> Phone -> H.323 Client. 3. In the phone configuration page type the IP address of the TANDBERG system in the Device name field, select device pool and push the insert button. 4. A pop-up box will now appear on the screen and ask you if you would like to configure the directory number. Push the ok button. 5. You should now see the Directory Number Configuration WEB page. Enter the E.164/phone number of your TANDBERG system in the Directory number field, and in the “Forward and Pickup Settings” enter the time of “No Answer Ring Duration”. The time selected has to have a value from 1 to 300 seconds. 6. Push the Add button to update the CallManager with the directory number settings. You have now configured the CallManager with a H.323 client and should be able to register the TANDBERG system to it. When the TANDBERG system is registered to a CallManager, it will be possible to place and receive calls from this system to any other video and voice systems that are registered on the same CallManager.

Glossary

Page 284 of the TANDBERG Edge MXP user manual — 6.14 Appendix 14
Page 284 · click to enlarge
Page 284

6.14 Appendix 14

Diagnostic Tools for IP To use these tools, will require using a PC and setting up a telnet session towards the system. Q.931 To show Q.931 trace during a call you need to issue the command ‘syslog on’. One can get traces for RAS, Q.931 and H.245 with this command. It is a complex trace and requires an extensive knowledge in H.323 signaling to be understood. Ping Ping is used to see if the system is able to reach a specific IP-address, using a mechanism in IP called ICMP. If the system is unable to register to its gatekeeper, or if it is unable to dial a specific endpoint, one can use ping to see if there is at least an IP-route to the gatekeeper or to the endpoint. In case you have problems, one would first ping the default gateway, then the gatekeeper, and then the other endpoint. Traceroute Traceroute does exactly that; it traces the route an IP-packet takes to reach its destination and displays all router hops. Traceroute is very useful for seeing exactly where there is a routing- problem in the IP-network, and for checking where transport-delay is introduced. Layer 4 Ports used in H.323 calls The layer 4 ports used by the system in a H.323 call can be defined as follows:

ƒ Dynamic: The ports are allocated at random from 2048 to 65535. ƒ Static: Will use the predefined layer 4 ports listed in the tables below.

Gatekeeper Discovery (RAS) 1719 UDP

Q.931 Call Setup 1720 TCP

H.245 Range 5555-5574 TCP

Video Range 2326-2341 UDP

Audio Range 2326-2341 UDP

Data/FECC Range 2326-2341 UDP

Point-to-point + Duo Video

Function Port Type

Page 285 of the TANDBERG Edge MXP user manual — 6.14 Appendix 14
Page 285 · click to enlarge
Page 285

Gatekeeper Discovery (RAS) 1719 UDP

Q.931 Call Setup 1720 TCP

H.245* Range 5555-5574 TCP

Video Range 2326-2405 UDP

Audio Range 2326-2405 UDP

Data/FECC Range 2326-2405 UDP

MultiSite + Duo Video (*) Note: While using MultiSite, if a site is disconnected and reconnected without terminating the entire conference, the next site to be connected will have a H.245 port outside of the specified range. If this functionality is required through a firewall, the range of TCP ports can be extended past 5564. However, if a site is disconnected and reconnected, without ending the conference enough times one can quickly end up outside of this range again.

Glossary · Function Port Type

Page 286 of the TANDBERG Edge MXP user manual — 6.15 Appendix 15
Page 286 · click to enlarge
Page 286

6.15 Appendix 15

System Upgrade Before starting the software upgrade of the TANDBERG MXP system, please make sure to have the new software file, (for instance s050000F30.pkg) and the Release Key for this software available. Your TANDBERG Partner will provide this for you. All options and settings will automatically be stored when upgrading, so no backup is necessary. If the system upgrade process is aborted before it's complete, the system will work as normal with the original software The TANDBERG MXP systems can be upgraded in three different ways;

ƒ Using the web interface ƒ Using FTP ƒ Using ISDN A) To upgrade using the web interface, please do the following steps: 1. Type the IP address of the TANDBERG MXP system that shall be upgraded (for instance 10.0.8.77) in a standard browser, such as Internet Explorer 6.0. 2. The web interface of the codec will then be displayed. Select the ‘System Configuration’ tab on top of the page, and then the sub-tab ‘Upgrade’. The following page will now be displayed:

Page 287 of the TANDBERG Edge MXP user manual — 6.15 Appendix 15
Page 287 · click to enlarge
Page 287
TANDBERG Edge MXP — 6.15 Appendix 15 diagram (page 287)
Fig. 136 · 6.15 Appendix 15

Figure 1 3. Enter the Release key in the ‘Release Key’ field and press the ‘Install Software’ button.

Glossary

Page 288 of the TANDBERG Edge MXP user manual — 6.15 Appendix 15
Page 288 · click to enlarge
Page 288

A new page will now be displayed:

TANDBERG Edge MXP — 6.15 Appendix 15 diagram (page 288)
Fig. 137 · 6.15 Appendix 15

Figure 2 4. Type in the path to where the new software file is stored, or select the file by using the ‘Browse’ button. 5. The progress for the sw upgrade can be tracked by pressing the ‘telnet’ link in the help text box BEFORE pressing the install button. Please note that this is not a necessary action for a successful software upgrade. An indication of the software upgrade progress will also be shown on the display of the system 6. Press the ‘Install’ button to start the software upgrade. When the software upgrade is complete, you need to click on the restart button and press OK to restart the system in order to activate the new software. Once verified, the system will reboot once more to complete the upload of all systems parameters kept from the old software revision. 7. To verify that the new sw is installed, refresh the page shown in figure1 after restart. The ‘Software Version’ should now show the new software version uploaded to the system. The same information can also be found in the menu on the system under ‘Control Panel/System Information’. B) Upgrading using FTP:

1. Copy the new software file to a folder on your harddisk, for instance c:\software. 2. Open a DOS window, and go to the folder where the new software is stored. 3. Type ftp . 4. Type in the supplied ‘Release Key’ as user.
Page 289 of the TANDBERG Edge MXP user manual — 6.15 Appendix 15
Page 289 · click to enlarge
Page 289

5. Type in your IP password (default is “TANDBERG”) as password. 6. Type ‘put and press Enter. The new software file will now be uploaded to the TANDBERG MXP system. 7. When the software upload is complete, end the ftp connection to the TANDBERG MXP system by typing ‘bye’ in the DOS prompt. 8. To exit the DOS window completely, type ‘exit’ 9. Restart the system to activate the new software. C) ISDN Upgrade The TANDBERG MXP systems have the possibility to be upgraded remotely from another TANDBERG MXP system using ISDN. Please note that both systems must be on software version F3.0 or newer for this functionality. Please also note that both systems must be on software version F3.0 or newer for this functionality 1. Connect to the system that shall be upgraded using ISDN 2. Copy the new software file to a folder on your computer, for instance c:\software. 3. Type the IP address of the TANDBERG MXP system that the software upgrade is going to be done from (for instance 10.0.8.77) in a standard browser, such as Internet Explorer 6.0. The web interface of the codec will then be displayed. 4. Select the ‘System Configuration’ tab on top of the page, and then the sub-tab ‘Far end upgrade’. The following page will now be displayed:

Glossary

Page 290 of the TANDBERG Edge MXP user manual — 6.15 Appendix 15
Page 290 · click to enlarge
Page 290
TANDBERG Edge MXP — 6.15 Appendix 15 diagram (page 290)
Fig. 138 · 6.15 Appendix 15

Figure 3 5. Enter the release key for the system to be upgraded in the ‘Release Key’ field. If no release key is given, the Far End System will use the previously stored release key if possible. This will work when upgrading from a main release to a dot release. 6 Make sure the setting “Far End System Upgrade” is set to “On” at the remote site. This setting can be found in the Administrator Settings/General/Permissions menu. 7. Enter the password set at the far end for remote upgrade (default password is “TANDBERG”) 8. Press ‘Install Software' .The system will now use about 90% of the call capacity to transfer the software file across. During this time, audio and video will be turned off. 9. Once the software has been transferred and verified at the far end, you will get a new webpage with information that the upgrade of the far end was successful. At the same time, a message box will appear at the remote system asking if you want to reboot the system to activate the new software. 10. To activate the new software. The ISDN connection needs to be closed, and the TANDBERG MXP system must be rebooted. In the menu on the system under ‘Control Panel/System Information’, the installed software should now be displayed as the ‘Software Version’.

Page 291 of the TANDBERG Edge MXP user manual — 6.16 Appendix 16
Page 291 · click to enlarge
Page 291

6.16 Appendix 16

TANDBERG Edge MXP — 6.16 Appendix 16 diagram (page 291)
Fig. 139 · 6.16 Appendix 16

Glossary · Declaration of Conformity

Page 292 of the TANDBERG Edge MXP user manual — A
Page 292 · click to enlarge
Page 292

7 Glossary

#

199 AV1: External input for the TANDBERG/LOEWE monitor.

2nd monitor: The second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor.

4CIF4 times CIF, 704x576 pixels
4SIF4 times SIF, 704x480 pixels

A

AACLDAdvanced Audio Coding Low Delay

Access code: Use Access codes to password protect outgoing calls.

Accessories boxThe cabinet contains the following: W.A.V.E. camera, table microphone,

remote control and tracker and documentation.

Accessories drawerSee Accessories box
AESStrong encryption. (Advanced Encryption Standard)
AGCAutomatic Gain Control. Maintains the audio signal level at a fixed value, by attenuating

strong signals and amplifying weak signals. Very weak signals, i.e. noise alone, will not be amplified.

Alert speakerThe internal speaker will warn you of an incoming call even though the monitor

may not be switched on.

Audio call: Audio call equals a telephone call. You can make a call with the video system with

audio only.

Audio input 4Intended for connection to an external microphone amplifier or an external fixed

mixer.

Audio input 5Intended for connection to external playback devices (or to telephone add-on

hybrids).

Audio input 6Intended for connection to a VCR or DVD player or other external playback

devices.

Audio out 1Intended for connection to TANDBERG Natural Audio, televisions or audio

amplifiers.

Audio out 2Intended for connection to audio recording equipment (or to a telephone add-on

hybrid).

Audio out 3: Intended for connection to a VCR or other recording equipment.

Auto-display snapshotSent and received snapshot will automatically appear on full screen

display.

Auto answer: The system will automatically answer all incoming calls.

Automatic Duo VideoDuo Video Mode is put to Auto. When starting a presentation, Duo Video

will start automatically (if possible).

Page 293 of the TANDBERG Edge MXP user manual — D
Page 293 · click to enlarge
Page 293

B

Bandwidth: Decides the quality of the video call. High bandwidth gives high quality.

Call Control Data TriggeredUses TxData, RxData and clock signals only. Use Data Triggered

when no handshake signal is available.

Call control Leased LineIs a non-dialing protocol and should be used when two systems are

connected in a point-to-point connection. Use Leased Line when the handshaking signals DTR and CD are available.

Call control ManualShould be used when no handshake signals are available, and the external

equipment requires a constantly connected line.

Call control RS366 DialingThe only dialing protocol and would normally be used together with

network clocking RS449/V35 Compatible when the external system uses RS2366 ports.

Call statusComprehensive information about the call listing transmitted and received

audio/video/data information.

Camera trackingVoice Activated Camera Positioning - the camera will automatically view the

current speaker.

Camera tracking modeVoice Activated Camera Positioning - the camera will automatically

view the current speaker.

Chair controlEnables one participant to control the meeting by selecting which of the

conference participants that is to be broadcasted to the other participants.

Channel statusComprehensive information about the call progress listing the numbers called,

and if an error occurs a cause code is displayed.

CIFCommon Intermediate Format, 352x288 pixels

Closed Captioning: Text chat.

Codec: The Codec is the heart of the system. The main task for the Codec is the compression of

outgoing video, audio and data, the transmission of this information to the far end, and the decompression of the incoming information.

Continuous PresenceSee Split Screen

Control Panel: The Control Panel is found in the main menu.

CSUChannel Service Unit

D

Daisy-chaining: Use of several cameras in a video conference.

Dataport: The system provides two standard RS 232 data ports to allow a computer to be

connected for data transfer and control purposes.

Dataport 1: A standard RS 232 data port to allow a computer to be connected for data transfer

and control purposes.

Dataport 2: Dedicated to the main camera and will not be available in standard configuration.

DESEncryption. (Data Encryption Standard)

DHCP: Dynamic Host Configuration Protocol.

Glossary

Page 294 of the TANDBERG Edge MXP user manual — F
Page 294 · click to enlarge
Page 294
DiagnosticsAllows testing of individual system components and displays the current system

settings.

Digital ClarityTF: Participants enjoy presentations of exceptionally high quality resolution video.

Disconnect siteAs a Chairman, you get the option to Disconnect site. Disconnect site allows

you to disconnect any participant in the conference.

Do Not Disturb: When Do Not Disturb is active the system will not accept any incoming calls.

The caller will hear a busy tone when calling the unit.

Document CameraA document camera is an additional camera that is used for showing text,

diagrams as well as physical objects.

DownspeedingTFIf channels are dropped during a videoconferencing session, the connection

is automatically maintained without interruption.

dual monitorThe second monitor

Dual monitor system: A videoconference system with two monitors.

Duo VideoTFAllows participants at the far end to simultaneously watch a presenter on one

screen and a live presentation on the adjoining screen.

E

E.164 AliasThe E.164 address of the system. Equivalent to a telephone number, sometimes

combined with access codes. The system will not register with the gatekeeper if the E164 alias is not set.

E1: Network type, 30 channels. Default for PAL versions.

Echo cancellerContinuously adjusts itself to the audio characteristics of the room and

compensates for any changes it detects in the audio environment.

Echo control: When set to On the far end is prevented to hear their own audio.

EncryptionUse encryption to make a secure call. The system will try to make point-to-point

calls using encryption. If the far end system supports encryption, the call will be encrypted. If not, the call will proceed without encryption. (Auto encryption). Set encryption to On if you don't want an unencrypted call to be established at all. Set encryption to Off if you don't want to use encryption.

End view: Stop viewing the site previously chosen with View Site, and return the view to the site

that is currently On Air. End view can be used by all conference participants.

Ethernet Speed: The speed (Mbps) on the connection from the system to the LAN.

F

Fallback to telephony: Enables fallback from video calls to telephony/speech calls.

Far End: In a video conference, Far End means the remote side of the conference. Far End

Camera is your conference partner's camera. Opposite to Near End

FECC: Far End Camera Control. When activated it is possible to control the far end's camera,

select video sources, activate presets and request still images.

Floor: In a multipoint call, use Request Floor to broadcast your picture to all other participants.

This is handy when you are having presentations, for teachers etc.

Page 295 of the TANDBERG Edge MXP user manual — H
Page 295 · click to enlarge
Page 295

G

G.711Audio algorithm for normal quality audio (telephone quality, 3.1 kHz) The system will

always have G.711 enabled.

G.722: Audio algorithm for high quality audio (7 kHz).

G.722.1Audio algorithm for compressed high quality audio (7 kHz)
G.728Audio algorithm for compressed normal quality audio (telephone quality, 3.1 kHz)

Gateway: The gateway enables sites on IP and sites on ISDN to participate in meetings with

each other.

Global Phone Book: A phone book provided by TMS.

H

H.261Video algorithm for legacy video compression and decompression. The system will always

transmit H.261

H.263Video algorithm for normal video compression and decompression
H.264Video algorithm for bandwidth-efficient video compression and decompression
Hardware serial numberA unique number (listed in the System Information menu) to identify

your system towards your TANDBERG representatives.

Humfilter: A highpass filter which reduces very low frequency noise.

iCIFInterlaced CIF, 352x288 pixels, 50 fields per second
Incoming callSomeone calls in to your system
Incoming MCU CallsIf occupied in a call, the system will provide a visual/audio indication of an

incoming call and ask to accept or reject the call.

IP address: Defines the network address of the system. This address is only used in static mode.

IP assignment: IP-address, IP-subnet mask and Gateway are assigned by the DHCP server.

IP assignment StaticThe system's IP-address and IP-subnet mask must be specified in the IP-

address field.

IP PrecedenceUsed to define which priority the system should have in the network. Higher

numbers indicate higher priority.

IP subnet mask: Defines the type of network. This address is only used in static mode.

IP TOS: IP Type Of Service. Helps a router select a router path when multiple paths are

available.

iSIFInterlaced SIF, 352x240 pixels, 60 fields per second

Layout: Use the Layout key to change picture layout on the screen.

Glossary

Page 296 of the TANDBERG Edge MXP user manual — N
Page 296 · click to enlarge
Page 296

M

Main CameraYour camera. Video input 1
Max call lengthThis feature will automatically end both incoming and outgoing calls when the

call time exceeds the length specified.

Max channelsIndicates the maximum number of channels the system is allowed to use on the

E1/T1 interface.

MCU: Multipoint Conference Unit.

MCU status lineShows indicators for MultiSite, MCU and DuoVideo

MicOff: Microphone is switched off.

Mix mode: How to adjust the weighting of each microphone to obtain the best possible audio and

minimize the background noise.

Modem mode: (Dataport) Supports external control of the system via a PC as in Control Mode.

Once a call is established, Dataport 1 will automatically switch to Data mode. When the call disconnects, Dataport 1 switches back to Control Mode.

MSNMultiple Subscriber Number. Makes it possible to attach several ISDN terminals, with

different numbers, to the same physical ISDN telephone line. The service can be ordered from the telephone company.

multipoint callA call with more than two participants including yourself
MultiSiteThe TANDBERG systems internal MCU. Built-in system which makes it possible to

establish meetings with up to 6 video calls and 5 telephone calls. The MultiSite option is not available on all systems.

MultiSite cascadingBy connecting up to 4 or 6 (depending on the system capacity) MultiSite

systems together to achieve a higher number of participants in a multipoint call.

N

NATNetwork Address Translation. NAT support in the videoconferencing system enables proper

exchange of audio/video data when connected to an external videoconferencing system when the IP traffic goes through a NAT router. Used in small LANs, often home offices, when a PC and a videoconferencing system is connected to a router with NAT support.

NAT AddressThe external/global IP-address to the router with NAT support. Packets sent to

the router will then be routed to the system's IP address.

Natural Audio ModuleTMDesigned to improve audio quality during a videoconference. It is

mounted in the cabinet above the Codec and consists of an audio system optimized for speech.

Natural Presenter Package: Consists of Duo Video, Digital Clarity and PC Presenter.

Natural VideoTF: 60 fields per second true interlaced picture.

Near EndIn a video conference, Near End means your own side of the conference. Near

Camera is your own camera. Opposite to Far End

Network clocking: Specifies the number of physical external clock signals.

Network Interface: Indicates if the network is of type E1 or T1.

Network profiles: It is possible to define up to 6 network profiles, each consisting of name and

call prefix, and 3 of them also include network selection.

Page 297 of the TANDBERG Edge MXP user manual — R
Page 297 · click to enlarge
Page 297
Non Standard FacilityThe network provider may require service selection in your ISDN

configuration. Valid NSF codes are from 1 to 31. 0 will disable NSF service codes.

NRNoise Reduction. Reduces constant background noise (e.g. noise from air-conditioning

systems, cooling fans, etc.).

NSF: Non Standard Facility.

NTSCNational Television System Committee. Video standard corresponding to 4SIF. Primary

used in USA, Japan and other countries.

O

Option KeyRequired by the system to activate optional features such as MultiSite and

Presenter.

P

PALPhase Alternation by Line. Video standard corresponding to 4CIF. Primary used in Europe,

Middle East and Asia

Parallel dial: Channels will be dialed and connected in parallel when setting up a bonding call.

PC PresenterTFAn easily accessible PC connection plug. When connected the PC image is

displayed on the monitor.

PC SoftPresenterTF: Shows PC images via the LAN connection.

PIPPicture-In-Picture
point-to-point callA call with two participants including your self

POP: Picture Outside Picture. POP is a picture layout mode that is optimized for wide screens:

Full screen, 1+3 layout and emulated dual monitor layout.

PresentationPresentation means to show another video source. Use the Presentation Key for a

predefined presentation source. Use the presentation menu to choose among all available video sources.

Presentation sourceThe video source that is on display when you press the Presentation Key

on the remote control

PresetsPredefined camera positions (and video sources)

Q

QCIFQuarter CIF, 176x144 pixels
QSIFQuarter SIF, 176x120 pixels

R

Release Floor: To end the request floor function.

Release floor to site: Allows the chairman to release the floor.

RemoteShort for Remote Control

Request Floor: The MCU will broadcast the video in full screen to all other participants in the

conference. If the MCU conference has a chairman, a request will be sent to the chairman.

Glossary

Page 298 of the TANDBERG Edge MXP user manual — S
Page 298 · click to enlarge
Page 298

Restart: Restarts the system.

Restore defaults: Restores system settings to the factory defaults.

Restricted call: A call to a 56 kbps network. By default the system will dial an unrestricted call (a

call to a 64 kbps network) and downspeed to 56 kbps if necessary.

S

S-VHSS-video

S-video: The standard camera uses one of the S-video inputs in the codec.

Selfview: Outgoing video. In most cases, this is the image of your self.

Serial numberA unique number (the hardware serial number, listed in the System Information

menu) to identify your system towards your TANDBERG representatives.

Side-by-SideSide-by-side view means that two pictures are displayed side by side each other

on the screen. You will se two equally sized pictures.

SIFStandard Input Format, 352x240 pixels

SNMP: Simple Network Management Protocol.

SNMP CommunitySNMP Community names are used to authenticate SNMP requests. SNMP

requests must have a password in order to receive a response from the SNMP agent in the system. The SNMP Community name is case sensitive.

SNMP Trap Host: Identifies the IP-address of the SNMP manager.

SNMP traps: Generated by the agent to inform the manager about important events.

SoftMuxEnsures high reliability and includes the unique Downspeeding feature. It also makes it

possible to dial to another videoconferencing equipment, phones and mobile phones in a uniform way, and provides an on-screen, real-time feedback on the progress of a call.

Split ScreenAll the participants in a MultiSite conference are displayed on the screen. (Former
Start ChannelIndicates the firstE1/T1 channel the system is allowed to use. The setting might

be used when if the E1/T1 line is shared with other equipment.

Start up video sourceThe video source that is on display when the system wakes up from

standby mode.

Status Format: Provides call quality feedback on the status line.

Streaming: Allows broadcasting of audio/video via an IP network.

Streaming AddressDefined as the IP-address of a streaming client, streaming server or a

multicast address.

Streaming Address PortIf several codecs are streaming to the same IP-address, different

ports have to be used in order for the client to know which stream to receive.

Streaming Allow remote StartStreaming can be started from the Videoconferencing system

using the remote control, by using the Data port, or from external user interfaces like the Web-browser or Telnet session.

Streaming AnnouncementsThe system will announce to the network that it is streaming. This

enables a streaming client (e.g. a PC) to connect to the system's streaming session. Used by Cisco IP/TV.

Streaming Password: Prevents unauthorized access to the streaming functionality.

Continuous Presence)

Page 299 of the TANDBERG Edge MXP user manual — T
Page 299 · click to enlarge
Page 299
Streaming SourceSelect between local video and/or far end video to be streamed. Local and

far end audio is always streamed.

Streaming TTL/Router HopsUsed for streaming data to limit how many routers the data should

pass before it is rejected.

Streaming Video Rate: Defines the Video streaming rate from the system.

SVGASuper VGA. (800x600)
SXGASuper extended Graphics Array (1280x1024)
System informationLists system numbers, line status, software version and other useful

information.

System nameIdentifies a videoconferencing system

T

T1: Network type, 24 channels. Default for NTSC versions.

T1 Line Coding: Indicates how the signals on the line should be coded. If parts of the systems

use restricted coding, this should be selected.

Take chairRequest chairmanship of the conference. If no one else is chairman, the request is

granted.

TCS-4: Used to address different systems on a LAN when dialing in via a gateway.

Terminal NamesLists the site numbers or name (if supported) of other sites connected in the

conference.

Terminate meetingThe chairman can terminate the conference, i.e. all participants are

disconnected.

TMSTANDBERG Management Suite

Touch Tones: To dial extension numbers etc. during a call, use touch tones in order to get tones

instead of preset on the number keys.

Tracker: The tracker is a small infrared remote control device made to steer the camera to any

desired location within the room.

TSC-1TCS-1 is used for H243 password on H320 MCU's
VCRVideo Cassette Recorder
VGAVideo Graphics Array. (640 x 480)
VGA Out QualityChanges the resolution of the VGA signal available in the VGA Out connector

at the rear of the codec.

View administrator settings: Displays all the system settings in a read only format.

View siteView any participant in the conference other than the participant currently On Air. Can

be used by all conference participants.

VNC: Virtual Network Computing.

Voice Switched: The active site will be displayed in full screen during a MultiSite conference.

Glossary

Page 300 of the TANDBERG Edge MXP user manual — W
Page 300 · click to enlarge
Page 300

W

WAVE II Camera: Wide Angle View Camera - delivers the widest angle of view in the industry.

Welcome menu: The welcome menu displays the main menu when you are outside a call.

XGAextended Graphics Array (1024 x 768)
Page 301 of the TANDBERG Edge MXP user manual — Table of contents
Page 301 · click to enlarge
Page 301

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Page 302 of the TANDBERG Edge MXP user manual — Table of contents
Page 302 · click to enlarge
Page 302

Table of contents

1 Introductionp.131.1 At a Glancep.161.2 Menu Structurep.202 Installationp.222.1 Unpacking and Mountingp.232.2 Connecting Cablesp.252.3 Monitor Configurationp.272.4 System Configurationp.283 General Usep.313.1 The Welcome Screenp.323.2 Using the Remote Controlp.333.2.1 Navigationp.373.2.2 Selfviewp.383.2.2.1 Local PC Displayp.383.2.3 Layoutp.403.2.3.1 Picture in Picturep.403.2.3.2 Picture outside Picturep.403.2.3.3 Auto Layoutp.403.2.4 Mic Offp.413.2.5 Volume + and -p.423.2.6 Number and Letter keysp.433.2.7 Touch Tonesp.443.3 On-screen Indicatorsp.453.4 Using the Menup.473.5 Make a Callp.493.5.1 Place Video Callp.503.5.2 Place Telephone Callp.513.5.3 Add Callp.523.5.4 Call Settingsp.543.5.5 Streamingp.553.6 Answer an incoming callp.573.7 End Callp.583.8 Standbyp.593.8.1 Delay Standby for 1 hourp.603.8.2 Delay Standby for 3 hoursp.613.8.3 Do Not Disturbp.623.9 Phone Bookp.633.9.1 Call Logp.643.9.2 My Contactsp.653.9.2.1 Add New Contactp.673.9.2.2 New MultiSite Contactp.683.9.2.3 Edit Contactp.703.9.2.4 Delete Contactp.713.9.3 Global Contactsp.723.9.3.1 Up one Levelp.733.9.3.2 Searchp.743.9.3.3 Copy Contact to My Contactsp.753.10 Camera Controlp.763.10.1 Move Camerap.773.10.2 Far End Controlp.783.10.3 Camera Presetsp.793.10.4 TANDBERG Trackerp.803.10.5 Picture Controlp.813.10.6 Camera Trackingp.823.11 Presentationp.833.11.1 Presentation Keyp.843.11.2 Presentation Menup.853.11.3 PC Presenter (DVI/VGA Input)p.863.11.4 PC Soft Presenter and VNCp.873.11.5 Dual Stream (DuoVideoTF/H.239)p.883.11.6 Take New Snapshotp.893.11.7 Display Snapshotp.903.12 Conference Servicesp.913.12.1 Request Floor and Release Floorp.943.12.2 Conference Layoutp.953.12.3 Terminal Namesp.963.12.4 Chair Controlp.973.12.5 Assign Floor and Release Floor from Participantp.983.12.6 View Site and End Viewp.993.12.7 Disconnect Participantp.1003.12.8 Terminate Meetingp.1013.12.9 More about MultiSite (embedded MCU)p.1023.13 Control Panelp.1043.13.1 Diagnosticsp.1053.13.2 System Informationp.1063.13.3 Channel Statusp.1073.13.4 Call Statusp.1093.13.5 System Selftestp.1103.13.6 View Administrator Settingsp.1113.13.7 IP Address Conflict Checkp.1153.13.8 Warningsp.1163.13.9 Text Chatp.1183.13.10 Audio Demop.1193.13.11 Administrator Settingsp.1203.13.12 Restartp.1213.13.13 User Guidep.1224 Administrator Settingsp.1234.1 General Settingsp.1244.1.1 Languagep.1254.1.2 System Namep.1264.1.3 International Namep.1274.1.4 Auto Answerp.1284.1.5 Phone Book Settingsp.1294.1.6 External Services Settingsp.1304.1.7 Permissionsp.1314.1.8 Screen Settingsp.1334.1.9 Software Optionsp.1394.1.10 Date and Time Settingsp.1404.2 Menu Settingsp.1414.2.1 Input Editor Languagep.1424.2.2 Menu Timeout in Callp.1434.2.3 Menu on TVp.1444.2.4 Menu on PCp.1454.2.5 Balloon Helpp.1464.2.6 Administrator Passwordp.1474.2.7 Kiosk Mode Settingsp.1484.2.8 Startupp.1514.2.9 Iconsp.1534.3 Presentation Settingsp.1544.3.1 Presentation Startp.1554.3.2 H.239p.1564.3.3 Startup Video Sourcep.1574.3.4 Presentation Sourcep.1584.3.5 Snapshot Sourcep.1594.3.6 Auto-Display Snapshotp.1604.3.7 PIP Appearancep.1614.3.8 PIP Placingp.1624.3.9 VNC Settingsp.1634.4 Call Qualityp.1644.4.1 Video Algorithmp.1654.4.2 Audio Algorithmp.1664.4.3 AAC-LD 128kbps (stereo audio)p.1674.4.4 Natural Videop.1684.4.5 Max Upstream Rate (kbps)p.1694.4.6 Video Qualityp.1704.4.6.1 Intelligent Video Management (IVM)p.1704.4.6.2 Native Resolutionsp.1714.4.7 Default Call Settingsp.1734.5 Audiop.1764.5.1 Inputsp.1774.5.2 Outputsp.1814.5.3 Echo Controlp.1834.5.4 Stereo Settingsp.1844.5.5 Audio Leveling (AGC)p.1864.5.6 Alert Tones and Volumep.1874.6 Videop.1884.6.1 Camera Tracking Modep.1894.6.2 MCU Status Linep.1904.6.3 Floor to Full Screenp.1914.6.4 Web Snapshotsp.1924.6.5 MultiSite Picture Modep.1934.6.6 Video Namep.1954.7 Securityp.1964.7.1 Encryptionp.1974.7.2 Encryption Modep.1984.7.3 Passwordsp.1994.8 Networkp.2004.8.1 ISDN/External/Leased E1/T1p.2014.8.1.1 ISDN-BRI Settingsp.202ISDN BRI switch typep.202Line setupp.202Advanced ISDN Settingsp.2034.8.1.2 ISDN-PRI Settingsp.204Number Rangep.204ISDN PRI Switch Typep.204Channel Huntingp.204Line Settingsp.205Advanced ISDN-PRI Settingsp.2054.8.1.3 Leased E1/T1 Settingsp.2074.8.1.4 External Network Settingsp.2084.8.1.5 H.331 Settingsp.2104.8.2 LAN Settingsp.2114.8.2.1 IP Settingsp.212DNS Settingsp.2144.8.2.2 H.323 Settingsp.215Gatekeeper Settingsp.216CallManager Settingsp.217Advanced H.323 Settingsp.2184.8.2.3 SIP Settingsp.219Display Namep.219Authenticationp.220Current RFC’s and Drafts supported:p.220Media Capabilities supported in SIP:p.2214.8.2.4 SNMP Settingsp.2224.8.2.5 IP Servicesp.2234.8.2.6 Quality of Servicep.2244.8.2.7 IEEE 802.1xp.2264.8.3 Network Profilesp.2274.8.4 Data Portp.2284.8.5 Restore Default Settingsp.2295 Peripheral Equipmentp.230Interfacesp.2315.1.1 Videop.2315.1.2 Audiop.2355.1.3 Networkp.2365.1.4 Data portp.2425.2 Document Camerap.2435.3 DVD / VCRp.2445.4 Additional Camerasp.2455.5 Additional Microphonesp.2465.6 The TANDBERG DNAM and Speakersp.248TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestrop.248The DNAM audiosystem is built on two specially designed and separate modules; the DNAM audio amplifier and the DNAM loudspeaker cabinet. The DNAM loudspeaker cabinet is based on several editions, one for each of the 6000 MXP, 6000 MXP Profile, 7000 MXP and 8000 MXP systems. For the 6000 MXP and the 8000 MXP system, the audio amplifier is integrated in the loudspeaker cabinet. For the Maestro system the amplifier and the loudspeaker cabinet is integrated directly into the system pedestal.p.248Using the external and optional Stereo Speaker Kit will improve the stereo sound, even on systems with integrated stereo speakers**. Note that the kit is not available for Mini-DNAM described below. Before connecting the Stereo Speaker Kit, make sure the complete videoconferencing system is powered down. When connecting the Stereo Speaker Kit to a system with already integrated stereo speakers, these integrated speakers will be disabled, and a new filter and specification setup is loaded when powering up the videoconferencing system.p.250TANDBERG 3000 MXP Profile:p.250The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versions made for fitting both the TANDBERG 3000 Profile 43’’ and 32’’ systems. The compact sized amplifier is mounted in the rear of the speaker cabinet.p.2505.7 Stereo Speaker Kitp.2525.8 Telephone Add-Onp.2545.9 Dual Monitorp.2555.10 XGA Monitors and Projectorsp.2565.11 VESA Display Power Managementp.2575.12 Digital Monitor Power Managementp.2585.13 Extended Display Identification Data (EDID)p.2596 Appendicesp.2616.1 Appendix 1p.2626.2 Appendix 2p.2656.3 Appendix 3p.2686.4 Appendix 4p.2696.5 Appendix 5p.2706.6 Appendix 6p.2736.7 Appendix 7p.2746.8 Appendix 8p.2756.9 Appendix 9p.2766.10 Appendix 10p.2776.11 Appendix 11p.2786.12 Appendix 12p.2816.13 Appendix 13p.2836.14 Appendix 14p.2846.15 Appendix 15p.2866.16 Appendix 16p.2917 Glossaryp.2928 Indexp.301
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
E1Network type, 30 channels. Default for PAL versions. p.294

Ask about the TANDBERG Edge MXP

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the TANDBERG Edge MXP

Be the first to ask — other owners or our team will answer.

Original document

TANDBERG Edge MXP manual PDF

302 pages·3.2 MB·Projector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…