Switch 4210 9-Port Switch 4210 18-Port Switch 4210 26-Port Switch 4210 52-Port
www.3Com.com Part Number: 10016119 Rev. AB Published: January, 2008

3Com Corporation 350 Campus Drive Marlborough, MA USA 01752-3064
Copyright © 2006-2008, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com and the 3Com logo are registered trademarks of 3Com Corporation.
Cisco is a registered trademark of Cisco Systems, Inc.
Funk RADIUS is a registered trademark of Funk Software, Inc.
Aegis is a registered trademark of Aegis Group PLC.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
All other company and product names may be trademarks of the respective companies with which they are associated.
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
3Com products do not contain any hazardous or ozone-depleting material.
Regulated Materials Statement


Thank you for purchasing a 3Com Switch 4210. As part of our commitment to bringing you the most capable and dependable network equipment, 3Com offers free software maintenance updates and documentation updates on our website.
To obtain the most up-to-date operating software and user documentation for the Switch 4210, point your web browser to: www.3Com.com/4210 and select the “Support and Registration” link.
You must register your 3Com switch before receiving software upgrades. To register, point your web browser to eSupport.3Com.com.
Before You Start The guide is intended for use by network administrators who install and set up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Release Notes The Release Notes provide important information about the current software release, including new features, modifications, and known problems. You should read the Release Notes before installing the switch in your network.
If the information in the Release Notes differs from this guide, follow the instructions in the Release Notes.
User guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) on the 3Com World Wide Web site at http://www.3com.com
Conventions Table 1 lists important conventions that are used throughout this guide.
Table 1 Notice Icons

6 ● 3Com Switch 4210 Family Command Reference
In addition to this guide, the Switch 4210 documentation set includes the following:
This guide contains information on the features supported by your switch and how they can be used to optimize your network. It is supplied in PDF format on the 3Com Web site.
This guide provides detailed information about the web interface and command line interface that enable you to manage the switch. It is supplied in PDF format on the 3Com Web site.
These notes provide information about the current software release, including new features, modifications, and known problems. The release notes are supplied in hard copy with your switch.

Overview The 3Com Switch 4210 Family provides high-performance, high-density, easy-to-install, NMS-manageable intelligent Ethernet switches that support wire-speed Layer 2 switching.
Three of the Switch 4210 Family models support industry standard IEEE 802.3af Power over Ethernet (PoE). Figure 1 displays these models and Table 1 provides a description of their features.
Figure 1 Power over Ethernet models

Table 1 Power over Ethernet models
Number of 10/100 Mbps ports
Number of 1000 Mbps uplink ports
Number of Console ports
Switch 4210 PWR 9-port AC input 8 One Combo port 1
Switch 4210 PWR 18-port AC input 16 Two Combo ports 1
Switch 4210 PWR 26-port AC or RPS DC input
24 1 (on rear)
Three of the Switch 4210 Family models are available for simple connectivity without PoE. Figure 2 displays these models and Table 2 describes its features.
Figure 2 Non Power over Ethernet models

Model Power supply

Table 2 Non Power over Ethernet models
Number of 10/100 Mbps ports
Number of Console ports
Number of 1000 Mbps uplink ports
Switch 4210 9-port AC input 8 One Combo port 1
Switch 4210 18-port AC input 16 Two Combo ports 1
Switch 4210 26-port AC input 24 Two Combo ports 1
Switch 4210 52-port (not shown)
AC input 48 Two 10/100/100 ports
Switch 4210 9-port PWR Front panel
Each Switch 4210 9-port PWR unit provides eight 10/100Base-TX autosensing Ethernet ports, one 10/100/1000Base-T Ethernet port, one 100/1000Base SFP ports, and one Console port. The SFP port and the 10/100/1000BASE-T Ethernet port form a Combo port. You can use either the SFP port or the 10/100/1000BASE-T Ethernet port at one time.
Figure 3 shows the front panel of a Switch 4210 9-port PWR.
Figure 3 Front panel of a Switch 4210 9-port PWR
( 1 ) ( 2 ) ( 3 ) ( 4 )

( 5 ) ( 6 ) ( 7 ) ( 8 )
(1) 10/100Base-TX autosensing Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) A/L LED
(6) D/S LED (7) Mode button
(8) Active LED for Combo port
Model Power supply · Two SFP ports

Introduction to the Switch 4210 Family PWR Switches 9
Figure 4 The Switch 4210 9-port PWR model’s rear panel

(1) AC power socket (
Each Switch 4210 9-port PWR provides a security slot through which you can lock the device together with an irremovable object to prevent theft. The security slot is located on the left side panel, as shown in Figure 7. n
If the left screw hole above the security slot is used, the security slot cannot be used.
Switch 4210 PWR 9-port units are able to power attached devices using standard 802.3af Power over Ethernet. The total available power for PoE on this model is 70W, enough to power four ports at full 15.4W required of the PoE standard. Each Switch 4210 9-port PWR unit supports AC input.
The Switch 4210 9-port PWR units each run two fans for heat dissipation.
18-port Front panel
Switch 4210s 18-port PWR each provide sixteen 10/100Base-TX autosensing Ethernet ports, two 10/100/1000Base-T Ethernet ports, two 100/1000Base SFP ports, and one Console port. Each SFP port and the corresponding 10/100/1000BASE-T Ethernet port form a Combo port. For each Combo port, either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port can be used at a time.
Figure 5 shows the front panel of a Switch 4210 18-port PWR.
( 1 )

Figure 5 Front panel of a Switch 4210 18-port PWR
(1) (2) (3) (4)

(1) 10/100Base-TX autosensing Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) A/L LED
(6) D/S LED (7) Mode button
(8) Active LED for Combo port
Figure 6 Rear panel of a Switch 4210 18-port PWR

(1) AC power socket
Each Switch 4210 18-port PWR provides a security slot, through which you can lock the device together with an irremovable object to prevent theft. The security slot is located on the left side panel, as shown in Figure 7.
( 1 )

Introduction to the Switch 4210 Family PWR Switches 11
Figure 7 Security slot on left side panel of a Switch 4210 18-port PWR

If the left screw hole above the security slot is used, the security slot cannot be used.
Switch 4210 18-port PWR units support AC input.
Switch 4210 PWR 18-Port units are able to power attached devices using standard 802.3af Power over Ethernet. The total available power for PoE on this model is 135W; enough to power 8-Ports at full 15.4W required of the PoE standard.
Switch 4210s 18-port PWR each run two fans for heat dissipation.
26-port Front panel
The Switch 4210 26-port PWR model provides 24 10/100Base-TX autosensing Ethernet ports, two 10/100/1000Base-T Ethernet ports, two 100/1000Base SFP ports, and one Console port. Each SFP port and the corresponding 10/100/1000BASE-T Ethernet port form a Combo port. For each Combo port, you can use either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port at one time.
Figure 8 shows the front panel of the Switch 4210 26-port PWR model.
(1)

Figure 8 The Switch 4210 26-port PWR model’s front panel
(1) (2) (3) (4)

(1) 10/100Base-TX autosensing Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) A/L LED
(6) D/S LED (7) Mode button
(8) Active LED for Combo port
Figure 9 Rear panel of a Switch 4210 26-port PWR

(1) AC power socket (2) DC power socket
Switch 4210 26-port PWR units support AC input or DC input.
Switch 4210 PWR 26-Port units are able to power attached devices using standard 802.3af Power over Ethernet. The total available power for PoE on this model is 370W; enough to power 24-Ports at full 15.4W required of the PoE standard.
3Com recommends a Redundant Power System (RPS) from Eaton Powerware for providing DC power to the Switch 4210 PWR 26-Port. For full details, refer to www.3com.com/rps
Switch 4210 26-port PWR units each run four fans for heat dissipation.
(1) (2) (3) · (3) Grounding screw

Introduction to the Switch 4210 Family PWR Switches 13
Power LED
Front Panel LEDs
Table 3 describes the power LED on the Switch 4210 PWR model.
Table 3 The power LED on the Switch 4210 PWR models
LED Mark on the panel Status Description
Power LED PWR ON The switch is powered on.
OFF The switch is powered off.
There are two port status LEDs on both sides (yellow LED on the left and green LED on the right) of the 10/100BASE-TX Ethernet port on the Switch 4210 PWR models. They indicate the port’s active, link, duplex, and speed status.
In addition, there is an A/L LED and a D/S LED on each Switch 4210 PWR model. These two LEDs indicate the port status LEDs mode. When the A/L LED is on, the port status LEDs respectively indicate the port’s active status and link status. When the D/S LED is on, the port status LEDs respectively indicate the port’s duplex status and speed status. Either the A/L LED or the D/S LED is on at one time. For details, see Table 4.
Table 4 Port status LEDs on the Switch 4210 PWR models
Port status mode LED Port status LED Description
The A/L LED is on
BLINKING The port is in the active state and there is traffic on the port.
OFF The port is in the active state but there is no traffic on the port.
ON The port is connected properly.
OFF The port is not connected or is incorrectly connected.
The D/S LED is on
ON The port operates in the full duplex mode.
OFF The port operates in the half duplex mode.
ON The port rate is 100 Mbps.
OFF The port rate is 10 Mbps.
You can change the mode of the port status LEDs by pressing the Mode button. After a switch is powered on, the A/L LED is on initially. If you press the Mode button, the D/S LED will be on. After that, if you press the Mode button again within 45 seconds, the A/L LED will be on again. Otherwise, the A/L LED will automatically be on 45 seconds later.
Table 5 describes the 1000 Mbps upline port status LED on the Switch 4210.
Table 5 The 1000 Mbps uplink port status LED on 4210 PWR models
Mark on the panel Status Description
1000 Mbps uplink port link LED
LINK ON The port is connected properly.
OFF The port is not connected or is incorrectly connected.

Table 5 The 1000 Mbps uplink port status LED on 4210 PWR models
Mark on the panel Status Description
1000 Mbps uplink port active LED
ACT BLINKING The port is in the active state and there is traffic on the port.
OFF The port is in the active state but there is no traffic on the port.
This section describes each Switch 4210 Family model.
The Switch 4210 9-port model provides eight 10/100Base-TX autosensing Ethernet ports, one 10/100/1000Base-T autosensing Ethernet port, one 100/1000Base-X SFP port, and one Console port. The SFP port and the 10/100/1000BASE-T autosensing Ethernet port form a Combo port. For the Combo port, either the SFP port or the 10/100/1000BASE-T Ethernet port can be used at a time.
Figure 10 shows the front panel of the Switch 4210 9-port model.
Figure 10 The Switch 4210 9-port model’s front panel

( 1 ) ( 2 ) ( 4 )
( 5 ) ( 6 ) ( 7 ) ( 8 )
(1) 10/100Base-TX autosensing port Speed LED (green)
(2) 10/100Base-TX autosensing port (3) Combo port Speed LED (green)
(4) 10/100/1000Base-T autosensing port (5) Console port
(6) 100/1000Base-X SFP port (7) Link/Act LED (green)
(8) Power LED (PWR)

Introduction to the Switch 4210 Family Non-PWR Models 15
Figure 11 The Switch 4210 9-port model’s rear panel

The Switch 4210 9-port model supports AC input.
The Switch 4210 cools off naturally.
The Switch 4210 18-port models provide 16 10/100Base-TX autosensing Ethernet ports, two 10/100/1000Base-T autosensing Ethernet ports, two 100/1000Base-X SFP ports, and one Console port. Each SFP port and the corresponding 10/100/1000BASE-T autosensing Ethernet port form a Combo port. For each Combo port, you can use either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port at one time.
Figure 12 shows the Switch 4210 18-port model’s front panel.
Figure 12 The Switch 4210 18-port model’s front panel

(1) 10/100Base-TX autosensing port Speed LED (green)
(2) 10/100Base-TX autosensing port (3) Combo port Speed LED (green)
(4) 10/100/1000Base-T autosensing port (5) Console port
(6) 100/1000Base-X SFP port (7) Link/Act LED (green)
(8) Power LED (PWR)
(1) (2) (4) · (3)

Rear panel
Figure 13 The Switch 4210 18-port model’s rear panel

AC input terminal block
The Switch 4210 18-port model’s support AC input.
3Com Switch 4210 non-PWR models cool naturallly through airflow.
The Switch 4210 26-port front panel provides 24 10/100Base-TX autosensing Ethernet ports, two 10/100/1000Base-T autosensing Ethernet ports, two 100/1000Base-X SFP ports, and one Console port. Each SFP port and the corresponding 10/100/1000BASE-T autosensing Ethernet port form a Combo port. For each Combo port, you can use either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port at one time.
Figure 14 shows the front panel of the Switch 4210 26-port model.
Figure 14 The Switch 4210 26-port front panel

(1) 10/100Base-TX autosensing port Speed LED (green)
(2) 10/100Base-TX autosensing port (3) Combo port Speed LED (green)
(4) 10/100/1000Base-T autosensing port (5) Console port
(6) 100/1000Base-X SFP port (7) Link/Act LED (green)
(8) Power LED (PWR)
(1) (2) (4) · (3)

Introduction to the Switch 4210 Family Non-PWR Models 17
Figure 15 The Switch 4210 26-port rear panel

(2) AC input terminal block
The Switch 4210 26-port model supports AC input.
3Com Switch 4210 non-PWR models cool naturally through airflow.
The Switch 4210 52-port front panel provides 48 10/100Base-TX autosensing Ethernet ports, two 10/100/1000Base-T autosensing Ethernet ports, two 100/1000Base-X SFP ports (The 4 gigabit ports are all active), and one Console port. Each SFP port and the corresponding 10/100/1000BASE-T autosensing Ethernet port form a Combo port. For each Combo port, you can use either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port at one time. The Switch 4210 52-port unit is displayed in Figure 16.
Figure 16 Switch 4210 52-port unit

The Switch 4210 52-port model supports AC input.
3Com Switch 4210 non-PWR models cool naturally through airflow.

Switch 4210 Family
Power LED
Front Panel LEDs
Table 6 describes the power LED on the Switch 4210.
Table 6 The power LED on the Switch 4210
LED Mark on the panel Status Description
Power LED Power ON The switch is powered on.
OFF The switch is powered off.
Table 7 describes the 10/100Base-TX autosensing port’s Link/Act LED.
Table 7 The Link/Act LED on the 3Com Switch 4210
Link/Act LED (green) ON The port is connected properly.
BLINKING The port is in the active state and there is traffic on the port.
OFF The port is not connected or is incorrectly connected.
Table 8 describes the Speed LED on the 10/100Base-TX port.
Table 8 The 10/100Base-TX port Speed LED on the Switch 4210
10/100Base-TX autosensing port Speed LED (green)
ON The port is operating at 100 Mbps.
OFF The port is operating at 10 Mbps.
For a description of the Link/Act LED of the Combo port, see Table 7. When the port is connected correctly, the Speed LED indicates the operating speeds of the Combo port, as shown in Table 9.
Table 9 The Combo port Speed LED on the Switch 4210
LED Operating port Status Description
Combo port Speed LED (green)
Connected to a 1000 Mbps optical module
ON The port is operating at 1000 Mbps.
Connected to a 100 Mbps optical module
OFF The port is operating at 100 Mbps.
ON The port is operating at 1000 Mbps.
OFF The port is operating at 10/100 Mbps.

Table 10 Technical specifications for the Switch 4210
Model Switch 4210 52-port Switch 4210 26-port Switch 4210 18-port Switch 4210 9-port
Physical dimensions (H × W × D)
43.6 x 440 x 225 mm
43.6 × 440 × 160 mm (1.7 × 17.3 × 6.3 in.)
43.6 × 360 × 160 mm (1.7 × 14.2 × 6.3 in.)
43.6 × 230 × 160 mm (1.7 × 9.1 × 6.3 in.)
(1.7 x 17.3 x 8.8 in.)
Weight 12.1 lbs (5.5 Kgs) 4.7 lbs (2.14 Kgs) 3.4 lbs (1.53 kg.) 2.3 lbs (1.06 kg.)
Number of fixed ports 48 x 10/100Base-TX
24 × 10/100Base-TX autosensing Ethernet ports
16 × 10/100Base-TX autosensing Ethernet ports
8 × 10/100Base-TX autosensing Ethernet ports
2 × 100/1000 Mbps Combo ports
2 × 100/1000 Mbps Combo ports
1 × 100/1000 Mbps Combo port
4 x 100/1000 Mps Combo ports
Number of management ports
1 × Console port
Power system AC input:
PoE (to power attachd deices)
Not supported Not supported Not supported Not supported
System power consumption (full load)
Fan None
0°C to 45°C (30°F to 113°F)
Table 11 Technical specifications for the Switch 4210 PWR models
Switch 4210 26-port PWR Switch 4210 18-port PWR Switch 4210 9-port PWR
Physical dimensions (H × W × D)
H 1.7 in 45 mm
H 1.7 in 45 mm
H 1.7 in 45 mm
W 17.3 in 440 mm
W 11.8 in 300 mm
W 11.8 in 300 mm
D 16.9 in 430 mm
D 9.2 in 233 mm
D 10.8 in 275 mm
Weight 13.4 lbs
6.0 lbs
4.9 lbs
6.09 Kgs
2.70 Kgs
2.22 Kgs
Number of fixed ports 24 × 10/100BASE-TX autosensing Ethernet ports
16 × 10/100BASE-TX autosensing Ethernet ports
8 × 10/100BASE-TX autosensing Ethernet ports
2 × 100/1000 Mbps Combo ports
1 × 100/1000 Mbps Combo port
2 × 100/1000 Mbps Combo ports
Number of management ports
1 × Console port

Table 11 Technical specifications for the Switch 4210 PWR models
Switch 4210 26-port PWR Switch 4210 18-port PWR Switch 4210 9-port PWR
Power system Switch 4210s 26-port PWR support AC input and DC input.
Switch 4210 18-port PWR/Switch 4210s 9-port PWR support only AC input.
AC input:
DC input:
All ports serve as PoE ports
System power consumption (full load)
25W + 123W PoE 20W + 62W PoE
15.4 W × 24 15.4 W × 8 15.4 W × 4
Number of fans 4 2 2
Operating temperature 0°C to 45°C (30°F to 113°F)
The Switch 4210 26-port, 18-port, and 9-port PWR models provide an over-temperature protection mechanism. When the internal temperature exceeds 65°C (149°F), they will stop providing power from all ports. When the temperature is below 60°C (140°F), they will continue to provide power from all ports.
Related Standards The 3Com Switch 4210 Family is designed to the following standards:
Function 8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast Ethernet), IEEE 802.3ab (Gigabit Ethernet), IEEE 802.1D (Bridging)
Safety UL 60950-1, EN 60950-1, CSA 22.2 No. 60950-1, IEC 60950-1
EMC Emissions EN55022 Class A, CISPR 22 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3
Safety Requirements The Earthing Lead shall comply with the following safety standards:
UL Subject 758, UL 1581 and CSA C22.2 No. 210
UL VW-1 and CSA FT1 Vertical Flame Test
Insulation Thickness 0.4mm

SFP Modules Supported for the Switch 4210 21
The Switch 4210’s front panel provides one or two 1000 Mbps SFP ports in which you can plug small form-factor (SFP) modules, which are described in Table 12.
Table 12 SFP modules supported by the Switch 4210
100 Mbps SFP module ■ 3CSFP81
1000 Mbps SFP module ■ 3CSFP91
100 Mbps bidirectional (BIDI) module ■ 3CSFP9-81
1000 Mbps BIDI module ■ 3CSFP85
Type Model


This section contains information that you need to install and set up your 3Com® switch. For information on upgrading your switch, refer to the Switch 4210 Release Notes available at www.3Com.com

Switch 4210 26-Port and 52-Port models are rack-mountable in a standard 19-inch rack. Switch 4210 9- and 18-Port models are not as wide as the 19-inch model and are intended for desktop or shelf installation.
Follow the steps below to mount a 26- or 52-Port model unit in a standard 19-inch rack:
1 Check that the rack is sturdy and properly grounded. Attach the rack-mount brackets to the front or rear panel of the chassis with screws.
2 Place the switch on a shelf in the rack and slide it to a proper position along the guide rails, reserving a suitable clearance between the device and the guide rails.
3 Fix the brackets to the rack posts with screws, making sure that the device is securely attached.

Rack-Mounting the Switch 25
Figure 17 Installing the switch in a 19-inch rack

Mount the front bracket as shown in Figure 18 and Figure 19.
Figure 18 Mount the front bracket to the device

Figure 19 Mount the front bracket to the mount angel of the rack

The Switch 4210 26-Port does not need rear brackets. The description for mounting rear brackets is only for the Switch 4210 PWR 24-Port.
Mount a screw on the back of the switch to closely connect the switch with the rear bracket to support the switch. There are three positions for screw mounting as shown in Figure 20.

Figure 20 Positions for screw mounting on the switch
Three positions for screw mounting
Three positions for screw mounting

Follow the steps below to mount the rear bracket:
1 Use screws to fix the rear bracket to the rear mount angle.
2 Determine the position for screw mounting on the switch according to the position of the mount angle.
3 Mount the screw to the switch and make sure the screw and the rear bracket are closely connected.
Figure 21 Installation completed 1

Screw 1: Fix the rear bracket to the mount angle.
Screw 2 is mounted to the switch.

Mounting the Switch on a Desktop 27
Figure 22 Installation completed 2

Screw 1: Fix the rear bracket to the mount angle.
Screw 2 is mounted to the switch.
In many cases, standard 19-inch racks are not available. Therefore, switches are often placed on a desktop. To place your switch on a desktop, you simply need to:
The following sections describe how to get your Switch 4210 powered-up and ready for operation.
4210 Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST), which takes approximately one minute.
During the Power On Self Test, all ports on the Switch are disabled and the LEDs light. The PWR LED will flash green during the POST.
When the POST has completed, check the PWR LED to make sure that your Switch is operating correctly. Table 13 shows possible colors for the LED.

Table 13 PWR LED Colors
Green The Switch is powered-up and operating normally.
Red The Switch has failed its Power On Self Test (POST).
Yellow flashing Some ports have failed POST*
Off The Switch is not receiving power.
* In this event you can still use the Switch using the remaining ports that have passed the POST.
If there is evidence of a problem, see “Solving Problems Indicated by LEDs” on page 52 for a list of suggested solutions.
The Switch 4210 26-port PWR has a -48V DC Redundant Power Supply socket.
Color State

Connecting a Redundant Power Supply 29
WARNING: When powering any Switch 4210 from an RPS, make sure that the unit is earthed (grounded) by either connecting the power cord to the unit or by connecting the earth terminal on the rear of the unit to a reliable electrical earth (or by connecting both). Ensure that the earth connection is made before connecting the DC supply from the RPS.
3Com switches that support -48V DC RPS inputs, and are PoE enabled, can only be powered by an RPS that complies with the isolation requirements of IEEE-Std 802.3af. Non PoE enabled switches do not have this restriction.
You can power the Switch 4210 using three methods:
The RPS provides two main benefits:
3Com’s redundant power solution allows you to use any off-the-shelf -48V DC RPS that meets the requirements defined in Table 11 on page 19.
For an approved vendor list, more details about purchasing the 3Com recommended RPS, and a full set of requirements go to:
The 3Com recommended RPS generates -48V DC power using power supply units (or rectifiers). The outputs of the rectifier(s) are connected together so that you can increase the total -48V power available by adding rectifiers. For example, three

1500W rectifiers can provide up to 4500W. Hot removal or insertion of a rectifier does not affect the -48V DC output voltage.
Table 14 shows an example of the total power available from several 1500W rectifiers.
A minimum of two rectifiers are required for each shelf to provide N+1 rectifier redundancy.
Table 14 Power Availability
1 2 3 4 5 6
- 1500W 3000W 4500W 6000W 7500W
The unearthed -48V DC power distribution provides the mechanism to connect to the Switch 4210. The distribution consists of several circuit breakers and connection terminals for the positive (common) and negative -48V outputs. Individually connect each Switch 4210 to a circuit breaker terminal.
You can also connect a battery to battery terminals prior to the DC power distribution to provide uninterrupted power and to be protected against the loss of AC mains power.
3Com’s RPS solution uses -48V DC power distribution. The RPS system provides bulk -48V DC power that is separately distributed to a number of network switches.
Each RPS consists of a shelf that can house from one to six rectifiers, a Distribution Module, and a Management Module.
When connecting the RPS to the switch, the circuit breaker and 2-core cables need to be matched to the switch’s power rating. Table 15 shows the recommended circuit breaker and cable rating for the Switch 4210. The recommended cable length should not exceed three metres (9.84 feet).
Table 15 Switch 4210 Circuit Breaker and Cable Ratings
Circuit Breaker Minimum 2-Core Cable Diameter
PoE 25A C type 12 AWG (solid or stranded cable)
Rectifiers · No Rectifier Redundancy · N+1 Rectifier Redundancy

Connecting a Redundant Power Supply 31
Figure 23 shows how to connect the power supply to the RPS socket in the back of the switch. Use the cable tie supplied with your switch to support the cable in the back of the RPS connector as shown in Figure 23.
Figure 23 RPS Connection to the Switch

When the RPS is connected to the switch, you can move the circuit breaker in the RPS to the closed (on) position and the switch will be powered by the -48V DC power.
The -48V DC power takes priority over the AC mains and powers the switch if it is connected.
Use the earthing cable that accompanies your switch if the length is suitable. Alternatively use the earthing cable specification as defined in “Earthing Lead” on page 20.
The earthing cable is only required if the switch is powered by the RPS only.
The recommended cable length should not exceed three meters (9.84 feet).
The Switch 4210 Power over Ethernet (PoE) units can supply power to any IEEE 802.3af compliant device through any of its front panel ports over a Category 5 or Category 5e Ethernet cable. The same cable connects the device to the network.
The Switch 4210 units can supply power through the 10/100 ports only.
Power over Ethernet is a self-configuring protocol. When you plug a PoE compliant device into one of the ports on the switch, the switch supplies the

power required to the device, providing that the total power budget for the switch is not exceeded.
A PoE switch combines the functionality of a standard Ethernet switch with a single power supply that can power multiple devices. Using a PoE switch has the following advantages over an non-powered network.
The switch supports resistor detection according to IEEE 802.3af and pre-standard detection methods.
The Switch 4210 supports 3Com 802.3af equipment. For the latest list of supported devices, refer to the product page on the 3Com web site at http://www.3com.com/
For additional information on Power over Ethernet, refer to the Power over Ethernet Configuration chapter in the Configuration Guide available on the 3Com Web site. Power over Ethernet management is available using the web interface or the command line interface (CLI).
A Console cable is an 8-core cable. One end of the cable is a crimped RJ-45 connector for the connection to the Console port of the switch, and the other end is a DB-9 female connector for the connection to the serial port on the Console terminal, as shown in Figure 24.
Figure 24 Console cable

Table 16 Console cable pinouts
RJ-45 Signal Direction DB9 (console)
2 DTR
3 TXD —> 2

Connecting the Console Cable 33
Table 16 Console cable pinouts
RJ-45 Signal Direction DB9 (console)
5 GND — 5
6 RXD <— 3
7 DSR
8 CTS
When you want to use the terminal to configure the switch, follow these steps to connect a terminal device to your switch using console cables:
1 Plug the DB-9 female connector of the Console cable to the serial port of the PC or terminal where the switch is to be configured.
2 Connect the RJ-45 connector of the Console cable to the Console port of the switch.
If the switch has been powered on:


To make full use of the features offered by your switch, and to change and monitor the way it works, you have to access the management software that resides on the switch. Managing the switch can help you to improve its efficiency and therefore the overall performance of your network.
This chapter explains the initial set up of the switch and the different methods of accessing the management software to manage a switch. It covers the following topics:
For information on the lost password procedure, refer to the Configuration Guide that is supplied with your switch.

To manage your switch you can use one of the following methods:
Each switch has a command line interface (CLI) that allows you to manage the switch from a workstation, either locally using a console port connection (see Figure 25), or remotely over the network (see Figure 26).
Figure 25 CLI Management using the Console Port

Figure 26 CLI Management over the Network

Refer to “Setting Up Command Line Interface Management” on page 47.
There are two main views in the CLI:
This view is shown when you first connect to the switch and shows basic information about operation and statistics. The prompt for user view is .
This view enables you to configure the system parameters. To display this view, from user view enter system-view. The prompt for system view is [4210].
The Switch 4210 supports Secure Shell version 2.0 (SSHv2.0), allowing secure access to the switch’s Command Line Interface.
If you use SSH to administer your switch and the network traffic is intercepted, no passwords or configuration information is visible in the data. To securely administer the switch using the Command Line Interface you need a third-party SSH client.
Each switch has an internal set of web pages that allow you to manage it using a Web browser remotely over an IP network (see Figure 27).

Setting Up Your Switch 37
Figure 27 Web Interface Management over the Network

Refer to “Setting Up Web Interface Management” on page 48.
SNMP Management You can manage a switch using any network management workstation running the Simple Network Management Protocol (SNMP) as shown in Figure 28. For a description of 3Com network management applications refer to “3Com Network Management” on page 63.
Figure 28 SNMP Management over the Network

Refer to “Setting Up SNMP Management” on page 49.
This section provides an overview of what you need to do to set up your switch so that you can manage it in its default state. The setup process is summarized in Figure 29. Detailed steps are provided in the sections that follow. In brief, you need to:

Figure 29 Initial Switch Setup and Management Flow Diagram

Plug and Play Setup Initial IP Information Setup Feature Management
Do you want to manually configure the IP information?
configured IP information? How do you want to connect to the Switch?
Connect to the con- sole port and use the Command Line Inter-
Connect to a front panel port and use the Web Interface or
How do you want to manage your Switch? See page 36
IP Configuration In order for the device to be remotely managed, it requires an IP address. You can use one of the following methods to allocate IP information to your switch.
When you configure the IP information, the switch remembers the information that you enter until you change it again. You should use the Manual IP configuration method if:
For most installations, 3Com recommends that you assign a known IP address to your switch. This makes management simpler and more reliable as it is not

Setting Up Your Switch 39
dependent on a DHCP or BootP server, and eliminates the risk of the IP address changing.
To manually enter IP information for your switch, refer to “Manually Configuring IP Information” on page 42.
By default the switch attempts to obtain an IP address from a DHCP server on the network without requesting user intervention. When using automatic IP configuration, it is important that the switch’s IP address is static so that you know what it is, otherwise it will be difficult to manage that switch. Most DHCP servers allow you to configure static IP addresses. Refer to the documentation that accompanies your DHCP server.
For a detailed description of how automatic IP configuration operates, refer to the Configuration Guide on the 3Com Web Site.
You should use the automatic IP configuration method if:
If the switch is not allocated with an automatic IP address, the IP configuration will be blank or shown as ‘’’’.
If you use the automatic IP configuration method, you need to discover the automatically allocated IP information before you can begin management.

If you allow the switch to automatically configure its own IP information you need to discover and view the IP information before you can begin to manage the switch. You can discover the IP information by:
You can view the automatically configured IP information using the command line interface (CLI) through a connection to the console port. This example describes a local connection to the console port, rather than a remote one using a modem. For further information on connecting using the console port see “Connecting the Workstation to the Switch”on page 42.
Viewing IP Information using the Console Port
You are now ready to view the automatically allocated IP information using the command line interface. To do so:
1 Connect your switch to the network using the Ethernet cable. As soon as a network connection is made the switch begins the automatic IP configuration process.
The automatic IP configuration process usually completes within one minute.
2 The CLI login sequence begins as soon as the switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, is displayed as shown in Figure 30.

Viewing Automatically Configured IP Information 41
Figure 30 User View Login

4 Enter display ip interface br to view a summary of allocated IP addresses.
The initial set up of your switch is now complete and and you can now set up a management method. See “Methods of Managing a Switch” on page 36 for details.
If you do not intend to use the CLI from the console port to manage the switch, you can logout, disconnect the serial cable, and close the terminal emulator software.
3Com has two management applications that will discover and help you manage your network. 3Com Network Supervisor is freely distributed PC software ideal for monitoring your network. It discovers your devices and connections, alerts you to network or configuration issues, assists you in registering your devices, and proactively monitors the health of your network.
3Com Network Director is chargeable PC software that adds advanced configuration and control to the features available from 3Com Network Supervisor.
Trial versions of both products are available at www.3com.com
You can use 3Com Network Supervisor or 3Com Network Director to discover the automatically allocated IP information. To do so:
1 Connect your switch to the network.
2 Launch 3Com Network Director or Network Supervisor and run the auto-discovery wizard.
The application discovers the new switch and displays the IP information that has been automatically allocated to the switch.
3 Power-up the switch and wait two minutes.
Most DHCP and BootP servers allow you to configure static IP addresses so that you know the switch’s IP address. Refer to the documentation that accompanies your DHCP or BootP server for more information on this topic.
If your network does not have a DHCP or BootP server, the workstation running 3Com Network Supervisor or 3Com Network Director must be on the same subnet as the switch because auto-IP addresses are not routable.

You can manually configure the switch IP information by:
To set up your switch manually you can make a connection to the console port, (this example describes a local connection to the console port, rather than one using a modem). You can do this while the switch is offline (before you connect the switch to a network) or while the switch is online (connected to a network).
Prerequisites
You can find pin-out diagrams for the cable in “Pin-outs” on page 57.
To connec the workstation to the switch, perform the following steps:
1 Connect the workstation to the console port using the console cable as shown in Figure 31.
Figure 31 Connecting a Workstation to the Switch using the Console Port
Workstation (with terminal emulation
To connect the cable:
a Attach the RJ-45 connector on the cable to the console port of the switch. b Attach the other end of the cable to the workstation and tighten the retaining screws on the cable to prevent it from being loosened.

Manually Configuring IP Information 43
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings must be set to match the default settings for the switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
3 Power up the switch. The Power on Self Test (POST) runs automatically. The Switch 4210 takes approximately one minute to boot.
To manually set up the switch with IP information using the command line interface perform the following steps
1 The command line interface login sequence begins as soon as the switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
2 At the login prompts, enter admin as your user name and press Return and at the password prompt press Return again. If you have logged on correctly, appears as shown below.
Once you have logged in you are automatically in User View.
*********************************************************** Switch 4210 9-Port BOOTROM, Version 4.01 ***********************************************************
Copyright(c) 2004-2007 3Com Corporation and its licensors. Creation date : May 29 2007, 19:14:41 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz Memory Size : 64MB Mac Address : 001ac16d080a
Press Ctrl-B to enter Boot Menu... 0 Auto-booting... Decompress Image OK! Starting at 0x80100000...
User interface aux0 is available.

Press ENTER to get started.
Username:admin Password: %Apr 1 23:57:15:490 2000 4210 SHELL/5/LOGIN:- 1 - admin(aux0) in unit1 login
3 Enter the system-view command and press Enter. The [4210] prompt is displayed.
4 Enter interface vlan 1 and press Enter.
5 Enter the IP address and subnet mask for the switch as follows:
and press Enter.
(where xxx.xxx.xxx.xxx is the IP address and mmm.mmm.mmm.mmm is the subnet mask of the switch)
6 Select the quit command and enter the default gateway for the switch:
(where xxx.xxx.xxx.xxx is the IP address of the default gateway)
7 From the User View, type save to save the switch’s configuration (this information is not saved automatically when the switch is powered down).
You can now set up your chosen management method. See “Methods of Managing a Switch” on page 36.
If you do not intend to use the command line interface using the console port to manage the switch, you can disconnect the serial cable and close the terminal emulator software.
You can manage your switch, including changing IP address information, by making a connection to a front panel port. You can then access the Command Line Interface or the Web interface, as desired. To do this you will need an IP address, refer to “Viewing Automatically Configured IP Information” on page 40 for more information.
The procedure described in this section assumes the unit has been powered up in standalone mode.
Login authentication

Manually Configuring IP Information 45
1 Connect the workstation to a front panel port using an Ethernet cable as shown in Figure 32.
Figure 32 Connecting a Workstation to the Switch using a Front Panel Port
Workstation (with a Network
Front Panel Port Connection Ethernet Cable
To connect the cable:
a Attach an RJ-45 connector at one end of the Ethernet cable to the Network Interface Card (NIC) in the workstation.
b Connect the RJ-45 connector at the other end of the cable to one of the front panel ports on the switch.
Do not interconnect the switch to any other unconfigured switch.
You can now review or change the switch’s IP information. You can do this using the Web interface or the command line interface (CLI) using telnet.
1 Power-up the switch. This takes approximately one minute.
2 Open a suitable Web browser and enter the IP address of your switch in the Address field.
If there is no response, wait for one minute then re-enter the IP address.
If a pop up message appears displaying download and install simplified Chinese information, click Cancel.
3 At the login prompt, enter admin as your user name, press Enter, and at the password prompt (default user name and password) press Enter again. If you have logged on correctly, the Device View of the switch is displayed.
4 To enter basic setup information for the switch, select Administration > IP Setup and then follow the wizard through various system screens to enter the IP
Switch · Interface Card · installed)

address and subnet mask that you want the switch to use when it is connected to the network. The final page displays a summary of the information entered.
5 Select Save Configuration to save the configuration to your switch.
The initial setup of your switch is now complete and you can now set up your chosen management method. See “Methods of Managing a Switch” on page 36.
1 To start a Telnet session to the unit, click Start in Microsoft Windows.
a Click Run.
b In the Open field, type the unit’s IP address: Telnet xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the switch’s IP address)
c Click OK.
2 Press Enter to open a login prompt.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login prompt, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, is displayed as shown below.
**************************************************************************** * Copyright(c) 2004-2007 3Com Corp. and its licensors. All rights reserved.* * Without the owner's prior written consent, * * no decompiling or reverse-engineering shall be allowed. * ****************************************************************************
Username:admin Password: %Apr 4 06:13:31:519 2000 4210 SHELL/5/LOGIN:- 1 - admin(10.10.11.222) in unit1 login
4 Enter the system-view command and Enter.
5 Enter interface vlan 1 and Enter.
6 Enter the IP address and subnet mask for the switch as follows:
(where xxx.xxx.xxx.xxx is the IP address and mmm.mmm.mmm.mmm is the subnet mask of the switch)
7 Enter the default gateway for the switch:
(where xxx.xxx.xxx.xxx is the IP address of the default gateway)
8 Enter the save command to save the configuration (the configuration is not saved automatically when the switch is powered down).
Login authentication

Setting Up Command Line Interface Management 47
The initial set up of your switch is now complete and you can set up your management method. See “Methods of Managing a Switch” on page 36.
This section describes how you can set up command line interface management using a local console port connection or over the network.
User Interface Overview User interface configuration is provided by the switch to configure and manage the port data. There are two types of user interfaces:
To manage a switch using the command line interface using the local console port connection:
1 Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 42.
2 Your switch is now ready to continue being managed and/or configured through the CLI using its console port.
To manage a switch using the command line interface over a network using Telnet:
1 Ensure you have already set up the switch with IP information as described in “Methods of Managing a Switch” on page 36.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the switch)
If you get an error message, check that your IP information was entered correctly and the switch is powered up.
4 To open a Telnet session using the DOS prompt, enter the IP address of the switch that you wish to manage in the following format:
>telnet xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the switch)
If opening a Telnet session using third party software you will need to enter the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).

If the login prompt does not display immediately, press Return a few times until it starts.
6 If you have logged on correctly, the switch you want to manage is displayed as , as shown in on page 44.
To set up command line interface management using SSH, refer to the chapter entitled “SSH Configuration” in the “3Com Switch 4210 Family Configuration Guide.”
This section describes how you can set up web interface management over the network.
Prerequisites ■ Ensure that you have already set up the switch with IP information as described in “Methods of Managing a Switch” on page 36.
To display the web interface correctly, use one of the following Web browser and platform combinations:
Table 17 Supported Web Browsers and Platforms
Windows 2000 Windows XP
Red Hat Linux 9
Netscape 7.1 Yes Yes No No Yes
Internet Explorer 5.5 Yes Yes Yes No No
Internet Explorer 6.0 Yes Yes Yes No No
Mozilla 1.4 No No No Yes Yes
For the browser to operate the web interface correctly, JavaScript™ and Cascading Style Sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings.

Setting Up SNMP Management 49
To manage a switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the switch)
If you get an error message, check that your IP information was entered correctly and the switch is powered up.
3 Open your web browser and enter the IP address of the switch that you wish to manage in the URL locator, for example, in the following format:
4 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
5 Click on the Device View button to display the web management options.
Any network management application running the Simple Network Management Protocol (SNMP) can manage a switch if the management workstation is connected to the switch using a port on the management VLAN. By default, the management VLAN is 1, and all ports on the switch are in VLAN 1.
For a description of 3Com’s network management applications, see Appendix C, “3Com Network Management” on page 63.
Prerequisites ■ The default read community string is public. The default write community string is private.
To manage your switch using an SNMP network management application, you need to specify SNMP community strings for the users defined on the switch. You can do this using the command line interface system management snmp community command. Refer to the command line interface section of the “SuperStack 4 Switch Command Reference Guide” for more information.
These switches support SNMP V1, V2, and V3. SNMP V3 is on as default. All commands are in snmp menu in System View.

If you intend to manage the switch using the web interface or the command line interface, or to change the default passwords, you need to log in with a valid user name and password. The switch has three default user names, and each user name has a different password and level of access. These default users are listed in Table 18.
Table 18 Default Users
Default Password Access Level
The user can view all manageable parameters, except special/security features, but cannot change any manageable parameters
The user can access and change the operational parameters but not special/security features
The user can access and change all manageable parameters
Use the admin default user name (no password) to login and carry out initial switch setup.
To set a password for the admin user in the CLI, enter the following from system view:
[4210]local-user admin <cr> [4210-luser-admin]password simple xxxxxxxx
(where xxxxxxxx is your chosen password).
Save the configuration in the User View.
For information on the lost password procedure refer to the Configuration Guide that is supplied with your switch.

This chapter helps you to diagnose and solve problems you may have with the operation of your switch. There is also an explanation of IP addressing and upgrading software.
The topics covered are:
If you experience a problem that is not listed here, it may be included in the Support section of the switch 4210 Command Reference Guide availabe on 3Com’s web site at www.3com.com
For Technical Support information, see “Obtaining Support for Your 3Com Products” on page 59.

Solving Problems Indicated by LEDs
If the LEDs on the switch indicate a problem, refer to the list of suggested solutions below.
Check that the power cable is firmly connected to the switch and to the supply outlet. If the connection is secure and there is still no power, you may have a faulty power cord or an internal fault. Check the power cord by:
The switch unit has failed its Power On Self Test (POST) because of an internal problem. The fault type will be indicated on the unit LEDs. Contact your supplier for advice.
A port has failed and has been automatically disabled. You can verify this by checking that the Port LED is quickly flashing Yellow. If a port fails, the switch passes its Power On Self Test and continues to operate normally.
The port has failed and has been automatically disabled. The switch passes its Power On Self Test and continues to operate normally, even if one or more ports are disabled.
Check that:
Auto-negotiation problems will occur with 10BASE-T or 100BASE-T where auto-negotiation is disabled and incorrect cables are being used (cross-over or straight).
Auto-negotiation problems will occur with fiber if:

Solving Hardware Problems 53
In the rare event of your switch unit experiencing a hardware failure, refer to the list of suggested solutions below.
Your switch has a fan monitoring system that will generate fan failure warning messages. Fan failure could potentially reduce the lifetime of the switch. The monitoring system polls the fan status at periodic intervals while the unit is powered up.
If one fan has failed in the switch, a warning message will be generated in the following ways:
The seven segment display will show a green flashing ‘f’.
If configured, an RMON trap is generated and sent to the management workstation.
An indication of a general hardware failure is provided through the Top level menu displayed when logging on to the CLI. For more detailed information about the failure select the display logbuffer command.
An indication of fan failure is provided through the Device Summary table for the specific unit. In addition all Summary tables turn red to indicate the fan failure.
If a fan failure warning message is generated:
1 Power off the unit.
2 Check that the air vents are not obstructed.
3 Power cycle the unit. To do this, remove and reconnect the AC mains supply. If another fan failure warning message is generated using the Command Line Interface or the Web interface, return the unit to 3Com.
1 Power cycle the unit. To do this, remove and reconnect the AC mains supply.
2 Check the command line interface (display logbuffer command) to determine whether a thermal shutdown has occurred.
3 If no, return the unit:
If yes, check that:
4 Power cycle the unit. If a further thermal shutdown occurs, and all environmental conditions are satisfactory, return the unit to 3Com.

Error message indicating that the SFP transceiver is invalid
The switch has identified that the SFP does not meet the minimum requirements for the switch and has disabled the port. To correct this problem, completely remove the SFP and replace it with a 3Com approved SFP.
To correct this problem, completely remove the SFP and then reinsert it. Alternatively, insert another identical SFP. If the problem persists, contact 3Com Technical Support.
If you experience communication problems with the switch, ensure that:
The following is a brief overview of IP addressing, and how to obtain a registered IP address.
To be managed correctly, each device on your network (for example a switch or Hub) must have a unique IP address. IP addresses have the format n.n.n.n where n is a decimal number between 0 and 255. An example IP address is 192.168.100.8.
The IP address is split into two parts:
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you access the Internet, you must apply for a registered IP address.
The IP registration system ensures that every IP address used is unique; if you do not have a registered IP address, you may be using an identical address to someone else and your network will not operate correctly.
InterNIC Registration Services is the organization responsible for supplying registered IP addresses. The following contact information is correct at time of publication:
If your IP network is internal to your organization only, that is, you do not access the Internet, you may use any arbitrary IP address as long as it is not being used by

Solving Fabric Formation Problems 55
another device on your network. 3Com suggests you use addresses in the range 192.168.0.0 to 192.168.255.255 with a subnet mask of 255.255.255.0.
These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
If you are having problems with correctly forming a fabric, first ensure that Spanning Tree is enabled. If it is enabled, do the following:
1 Power off all units in the fabric.
2 Check all the cable connections in the fabric.
3 Check the ports have been enabled as fabric ports.
4 Power on all units in the fabric.


A
Null Modem Cable RJ-45 to RS-232 25-pin

PC-AT Serial Cable RJ-45 to 9-pin

Screen DCD RxD TxD DTR Ground DSR RTS CTS

Modem Cable RJ-45 to RS-232 25-pin

10/100 and 1000BASE-T RJ-45 connections.
Table 10 Pin assignments

Table 11 Pin assignments


B
3Com offers product registration, case management, and repair services through eSupport.3com.com. You must have a user name and password to access these services, which are described in this appendix.
To take advantage of warranty and other service benefits, you must first register your product at:
3Com eSupport services are based on accounts that are created or that you are authorized to access.
Solve Problems Online 3Com offers the following support tool:
It contains thousands of technical solutions written by 3Com support engineers.
To enhance response times or extend your warranty benefits, you can purchase value-added services such as 24x7 telephone technical support, software upgrades, onsite assistance, or advanced hardware replacement.
Experienced engineers are available to manage your installation with minimal disruption to your network. Expert assessment and implementation services are offered to fill resource gaps and ensure the success of your networking projects. For more information on 3Com Extended Warranty and Professional Services, see:
Contact your authorized 3Com reseller or 3Com for additional product and support information. See the table of access numbers later in this appendix.
You are entitled to bug fix / maintenance releases for the version of software that you initially purchased with your 3Com product. To obtain access to this software, you need to register your product and then use the Serial Number as your login. Restricted Software is available at:

To obtain software releases that follow the software version that you originally purchased, 3Com recommends that you buy an Express or Guardian contract, a Software Upgrades contract, or an equivalent support contract from 3Com or your reseller. Support contracts that include software upgrades cover feature enhancements, incremental functionality, and bug fixes, but they do not include software that is released by 3Com as a separately ordered product. Separately orderable software releases and licenses are listed in the 3Com Price List and are available for purchase from your 3Com reseller.
Contact Us 3Com offers telephone, internet, and e-mail access to technical support and repair services. To access these services for your region, use the appropriate telephone number, URL, or e-mail address from the table in the next section.
To obtain telephone support as part of your warranty and other service benefits, you must first register your product at:

When you contact 3Com for assistance, please have the following information ready:
To send a product directly to 3Com for repair, you must first obtain a return materials authorization number (RMA). Products sent to 3Com without authorization numbers clearly marked on the outside of the package will be returned to the sender unopened, at the sender’s expense. If your product is registered and under warranty, you can obtain an RMA number online at http://eSupport.3com.com/ First-time users must apply for a user name and password.
Telephone numbers are correct at the time of publication. Find a current directory of 3Com resources by region at: http://csoweb4.3com.com/contactus/
Country Telephone Number Country Telephone Number
Asia, Pacific Rim — Telephone Technical Support and Repair
Australia Hong Kong India Indonesia Japan Malaysia New Zealand
1800 075 316 2907 0456 000 800 440 1193 001 803 852 9825 03 3507 5984 1800 812 612 0800 450 454
1800 144 10220 or 029003078 800 810 0504 800 616 1463 080 698 0880 00801 444 318 001 800 441 2152
PR of China Singapore South. Korea Taiwan Thailand
Pakistan Call the U.S. direct by dialing 00 800 01001, then dialing 800 763 6780 Sri Lanka Call the U.S. direct by dialing 02 430 430, then dialing 800 763 6780 Vietnam Call the U.S. direct by dialing 1 201 0288, then dialing 800 763 6780
You can also obtain non-urgent support in this region at this email address apr_technical_support@3com.com Or request a return material authorization number (RMA) by FAX using this number: +61 2 9937 5048, or send an email at this email address: ap_rma_request@3com.com
Europe, Middle East, and Africa — Telephone Technical Support and Repair
From anywhere in these regions not listed below, call: +44 1442 435529
From the following countries, call the appropriate number:
Contact Us 61 · Philippines

Country Telephone Number Country Telephone Number
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
0800 297 468 0800 71429 800 17309 0800 113153 0800 917959 0800 182 1502 06800 12813 1 800 553 117 180 945 3794 800 879489
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
800 23625 0800 0227788 800 11376 00800 4411 357 800 831416 0800 995 014 900 938 919 020 795 482 0800 553 072 0800 096 3266
You can also obtain support in this region using this URL: http://emea.3com.com/support/email.html
You can also obtain non-urgent support in this region at these email addresses: Technical support and general requests: customer_support@3com.com Return material authorization: warranty_repair@3com.com Contract requests: emea_contract@3com.com
Latin America — Telephone Technical Support and Repair
Antigua Argentina Aruba Bahamas Barbados Belize Bermuda Bonaire Brazil Cayman Chile Colombia Costa Rica Curacao Ecuador Dominican Republic
1 800 988 2112 0 810 444 3COM 1 800 998 2112 1 800 998 2112 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guatemala Haiti Honduras Jamaica Martinique Mexico Nicaragua Panama Paraguay Peru Puerto Rico Salvador Trinidad and Tobago Uruguay Venezuela Virgin Islands
AT&T +800 998 2112 57 1 657 0888 AT&T +800 998 2112 1 800 998 2112 571 657 0888 01 800 849CARE AT&T +800 998 2112 AT&T +800 998 2112 54 11 4894 1888 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 657 0888
You can also obtain support in this region in the following ways:
US and Canada — Telephone Technical Support and Repair

3Com has a range of network management applications to address networks of all sizes and complexity, from small and medium businesses through large enterprises. The applications include:
Details of these and other 3Com Network Management Solutions can be found at www.3com.com/network_management
3Com® Network Supervisor (3NS) is an easy-to-use management application that graphically discovers, maps, and monitors the network and links. It maps devices and connections so you can easily:
3NS is configured with intelligent defaults and the ability to detect network misconfigurations. It can also offer optimization suggestions, making this application ideal for network managers with all levels of experience.
To find out more about 3Com Network Supervisor and to download a trial version, go to: www.3com.com/3ns
3Com Network Director (3ND) is a standalone application that allows you to carry out key management and administrative tasks on midsized networks. By using 3ND you can discover, map, and monitor all your 3Com devices on the network. It simplifies tasks such as backup and restore for 3Com device configurations as well as firmware and agent upgrades. 3ND makes it easy to roll out network-wide configuration changes with its intelligent VLAN configuration tools and the powerful template based configuration tools. Detailed statistical monitoring and historical reporting give you visibility into how your network is performing.

To find out more about how 3Com Network Director can help you manage your 3Com network and to download a trial version, go to: www.3com.com/3nd
3Com Network Access Manager is installed seamlessly into Microsoft Active Directory and Internet Authentication Service (IAS). It simplifies the task of securing the network perimeter by allowing the administrator to easily control network access directly from the “Users and Computers” console in Microsoft Active Directory. With a single click, a user (or even an entire department) can be moved to a different VLAN, or a computer can be blocked from connecting to the network.
3Com Network Access Manager leverages the advanced desktop security capabilities of 3Com switches and wireless access points (using IEEE 802.1X or RADA desktop authentication) to control both user and computer access to the network.
To find out more about 3Com Network Access Manager, go to: www.3com.com/NAM

3Com Enterprise Management Suite 65
3Com Enterprise Management Suite (EMS) delivers comprehensive management that is flexible and scalable enough to meet the needs of the largest enterprises and advanced networks.
This solution provides particularly powerful configuration and change control functionalities, including the capability to:
The client-server offering operates on Windows and UNIX (Linux and Solaris) systems.
3Com EMS is available in four packages, varying in the maximum number of devices actively managed. These include SNMP-capable devices such as switches, routers, security switches, the 3Com VCX™ IP Telephony server, and wireless access points:
To find out more about 3Com Enterprise Management Suite, go to: www.3com.com/ems
3Com Integration Kit for HP OpenView Network Node Manager offers businesses the option of managing their 3Com network directly from HP OpenView Network Node Manager. The kit includes Object IDs, icons, MIBs, and traps for 3Com devices. The package supports both Windows platforms and UNIX or Solaris platforms. It can be installed as a standalone plug-in to HP OpenView, or used with a 3Com management application such as 3Com Enterprise Management Suite (EMS).
To find out more about 3Com Integration Kit for HP OpenView Network Node Manager, go to: www.3com.com/hpovintkit


WARNING: When powering any Switch 4210 from an RPS, the unit must be earthed (grounded). This can be achieved by either connecting the power cord to the unit or by connecting the earth terminal on the rear of the unit to a reliable electrical earth, or by connecting both. It must be ensured that the earth connection is made before connecting the DC supply from the RPS.

FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
Information to the User If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
How to identify and resolve radio-TV interference problems
This booklet is available from the U.S. Government Printing Office, Whashington, DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.
ICES Statement This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A respecte Class A est conforme a la norme NMB-003 du Canada.
CE Statements (Europe) EU Representative: 3Com Europe Limited Peoplebuilding 2, Peoplebuilding Estate Maylands Avenue Hemel Hempstead, Hertfordshire HP2 4NW United Kingdom
This product complies with the European Low Voltage Directive 73/23/EEC as amended by European Directive 93/68/EEC and EMC Directive 2004/108/EC.
A copy of the signed Declaration of Conformity can be downloaded from the Product Support web page for the Switch 4210 Product Family at http://www.3com.com
Also available at http://support.3com.com/doc/Switch_4210_EU_DOC.pdf

Regulatory Notices 73

Pages referenced in this manual — manufacturer, support and downloads.