SiPass integrated

AFI5100

Installation manual

Page 2 of the Siemens AFI5100 user manual — AFI5100
Page 2 · click to enlarge
Page 2

Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. Supply subject to availability. © 2005 Copyright by Siemens Building Technologies AG

Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.

We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.

Page 5 of the Siemens AFI5100 user manual — 6FL7820-8CB10 AFI5100 – Input Point Module and base-plate
Page 5 · click to enlarge
Page 5
Siemens AFI5100 — Input Point Module (AFI5100) diagram (page 5)
Fig. 1 · Input Point Module (AFI5100)

Fig. 1 Input Point Module

1.1 Product Description

The AFI5100 is an Input Point Module used as part of a Siemens integrated access control and security solution. It provides an interface between an Advanced Access Controller (ACC) and up to 32 input devices used to monitor a secure facility.

The AFI5100 continuously monitors the status of all input devices connected; for example, Passive Infrared Detectors (PIRs). Any changes in state are instantly communicated to the ACC and then on to the Host system if necessary.

1.2 Product Numbers

6FL7820-8CB10 AFI5100 – Input Point Module and base-plate

1.3 Prerequisites

z Input Devices to be connected to the IPM

z Cabling (RS-485)

z Required Tools & Materials

z Medium-duty drill and associated drill-bits (if required)

z 4 mounting screws or standoffs (approx. 4mm)

z Flat-blade terminal screwdriver

z Wire cutters

z Cable strippers

Page 6 of the Siemens AFI5100 user manual — 1.6 Wiring
Page 6 · click to enlarge
Page 6

1.4 Expected Installation Time

30 minutes

1.5 Mounting Instructions

1. Remove the AFI5100 from its carton and discard the packaging material.
2. Place the AFI5100 (base-plate) against the surface to which it is to be affixed and mark the location of the mounting holes.
3. If being mounted within a cabinet, simply align the AFI5100 base-plate with the holes located on the cabinet backplane and proceed to step 3.
4. It is recommended that you affix the AFI5100 in all four of the mounting locations.
5. Select the appropriate drill bit according to the mounting surface / hole size and drill the holes in the locations marked (if required).
6. Fasten the AFI5100 base-plate to the surface using the correct type of screws or standoffs for the surface.
7. Connect the cabling to the AFI5100 PCB (as described in the next section titled ‘Wiring’).
8. Apply power to the AFI5100 and test its operation.
9. This step may require installation and programming of the access control host software and download of the firmware instruction set. Alternatively, the firmware and configuration may be carried out using the FLN Field Service Tool.

1.6 Wiring

It is recommended that you wear a grounding strap while carrying out this proce- dure.

1. Connect all input devices to the INPUT ports.

Listed end-of-line resistors must be connected to the wiring for each input device if they are to be supervised. If supervised, cable must be shielded and total cable run resistance must not exceed 100 Ohms. Cable shielding must be unconnected at the device end, and connected to the board earth at the IPM end.

2. Connect any devices to the OUTPUT ports.
3. Connect appropriate wiring to the FIRE OVERRIDE INPUT port if required.

Listed end-of-line resistors must be connected to the Fire Over-ride Input wires if you are implement- ing Enhanced Fire Over-ride. Enhanced mode requires the connection of 22Kohm supervision resistor circuits. Cable must be shielded and total cable run resistance must not exceed 100 Ohms.

Page 7 of the Siemens AFI5100 user manual — Expected Installation Time
Page 7 · click to enlarge
Page 7
4. Connect the next device in the Fire Override sequence to the FIRE OVERRIDE OUTPUT port if required.
5. Connect the FLN wires (from the ACC) to the RS485 BUS port.
6. If the FLN cable is long or subject to high noise, ensure that the jumper across link LK10 (EOL) has been made. This only applies to units located on the ends of bus lines.
7. Connect the active (+ve) and neutral (-ve) wires from the Power Supply Unit (PSU) to the POWER IN port. Ensure the polarity of the connection is made correctly.
8. Check all connections thoroughly.
9. Power can now be applied to the AFI5100 .The following diagram displays the layout and dimensions of the AFI5100 with brace attached:
Siemens AFI5100 — Expected Installation Time diagram (page 7)
Fig. 2 · Expected Installation Time
Page 8 of the Siemens AFI5100 user manual — The following table provides a brief description of each port:
Page 8 · click to enlarge
Page 8

The following diagram displays the location of the ports on the AFI5100 :

Siemens AFI5100 — Expected Installation Time diagram (page 8)
Fig. 3 · Expected Installation Time

9 4 5 6 7 8

The following table provides a brief description of each port:

Siemens AFI5100 — The following table provides a brief description of each port: diagram (page 8)
Fig. 4 · The following table provides a brief description of…
Name Brief Description T 17 – INPUT 32 Inputs for Ports 1 - 32 devicesconnection to monitoring and input T 1 – INPUT 16 Inputs for Ports 1 - 16 devicesconnection to monitoring and input IN Input for F Over-ride Input Portire Over-ride wiring ower IN DC powerinput OUT Fire OverOver-ride Output Port ride sequeride for connecting devices in Fire Overnce 1 – OUT 4 Auxiliary R ut Ports 1 - 4elay-driven Outputs OUT 1-12V OUT 2 12 V DC p iary 12 V DC Power Supply 1-2ower source AL IN OUT Local inpu per In/Out Port alarmt and output for tamper detection and 5 BUS RS485 co ACC FLNmmunications port for connection to an channel
Page 9 of the Siemens AFI5100 user manual — The following table outlines the link settings for the AFI5100 :
Page 9 · click to enlarge
Page 9

1.7 Links and Jumpers

The following table outlines the link settings for the AFI5100 :

LinkDescriptionValue LK1, LK2Links 1 and 2 are used to configure whether Fire Over-ride (FOR) will operate in Enhanced FOR mode or Normal. Enhanced mode also requires the connection of a supervision circuit to the Fire Over-ride Input.To enable Normal Mode: LK1 LK2 NORMAL FORTo enable Enhanced Mode: LK1 LK2 NORMAL FOR LK4, LK6Links 4 and 6 control whether Fire Over-ride (FOR) is enabled. If the links are set to FOR operation, activation of the FOR input will cause the outputs to return to the NO position. If the links are set to the off position, FOR input will have no effect on the state of the output relays.FOR operation active: LK4 LK6 ENABLE FORFOR operation ignored: LK4 LK6 ENABLE FOR LK3, LK5These auxiliary links have been included for further enhancement of the system. LK7LK7 affects the reset action when the RESET link (LK9) is set and the power turned on. See LK9 below for a description of how to reset the unit.LK7 If the jumper on Link 7 is set as shown, it is set to “Full Reset” mode. LK7 If the jumper on Link 7 is taken off, it is set to “Partial Reset” mode. LK8This is a General Purpose links that has been included for further enhancement of the system. LK9Memory Clear and Reset Setting LK9 and turning the power off and on will reset the IPM. A full or partial reset can be achieved by setting LK7 on or off. If LK7 is set, the IPM will fully reset and any firmware loaded into the memory will be erased. You will need to re-program the IPM with firmware again before it can operate. If LK7 has the jumper removed, the microcontroller will be rebooted but the firmware will remain in memory. LK10EOL Termination (Bus) This link allows the RS485 BUS communications channel to be terminated in noisy or lengthy comms. Note: Units located at the end of bus lines only should have this link set.RS485 BUS port not terminated. LK10 EOLRS485 BUS port terminated. LK10 EOL LK11 – LK14FOR Activation These links allow FOR activation to be enabled or disabled for each individual relay output. Enabling Fire Override for a relay means that when the FOR input is activated, the relay output switch to the NO position.LK11 LK12 FOR EN FOR DIS In the above diagram LK11 (Relay 1) is set to FOR Enabled and LK12 (Relay 2) is set to FOR Disabled.
Page 10 of the Siemens AFI5100 user manual — 1.8 LEDs
Page 10 · click to enlarge
Page 10

1.8 LEDs

The following table describes the operation of the LEDs located on the AFI5100 :

LEDBrief Description POWERThe POWER led is illuminated when power has been applied to the device. ACTIVITYThe ACTIVITY led indicates that the AFI5100 is accessing information contained in its internal database or performing a routine operation. This LED also indicates whether the initial instruction set has been downloaded. If power is applied and the LED blinks quickly, the AFI5100 instruction set (firmware) needs to be downloaded. If the LED is blinking slowly, approximately once per second, a firmware set has already been downloaded. Tx COMMSThe Transmission COMMS LED flashes when the IPM is sending data to the ACC to which it has been connected (via an FLN). Rx COMMSThe Transmission COMMS LED flashes when the IPM is receiving data from the ACC to which it has been connected (via an FLN). InputsThe tricolor Input Port LEDs indicate the current status of the input port. See the table below for an explanation of the colors. OutputsEach Output Relay has a corresponding LED that is illuminated when the relay is activated. FireThe Fire LED is illuminated when Fire Over-ride is activated.

Each input LED may be in one of two states as indicated by color.

LED ColorInput statusFire Over-ride status GreenDenotes input Normal: ClosedDenotes FOR Normal: Closed OrangeDenotes input Normal: OpenDenotes FOR Normal: Open (alarm)
Page 11 of the Siemens AFI5100 user manual — 1.10 Programming and Firmware Download
Page 11 · click to enlarge
Page 11

1.9 Recommended Cable Specifications

The following table outlines the cable recommended for connection of an inte- grated security system:

Communication TypeRecommended Cable Specifications CorePairsAWGStrandingWire TypeInsulationShieldJacket RS48542287 x 36Tinned CopperPolyethyleneAluminium foilPolyester tape / braided shieldPVC 63287 x 36Tinned CopperPolyethyleneAluminium foilPolyester tape / braided shieldPVC 84287 x 36Tinned CopperPolyethyleneAluminium foilPolyester tape / braided shieldPVC RS23242247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC 63247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC 84247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC RS42242247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC 63247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC 84247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC RJ-458424SolidBare CopperPolyethyleneUnshieldedPVC 84247 x 32Tinned CopperPolyethyleneUnshieldedPVC RJ-128424SolidBare CopperPolyethyleneAluminium foilPolyester tape / no braidPVC 84247 x 32Tinned CopperPolyethyleneAluminium foilPolyester tape / no braidPVC Power (12/24 V DC)211819 x 30Tinned CopperPolyethyleneUnshieldedPVC
Siemens AFI5100 — 1.9 Recommended Cable Specifications diagram (page 11)
Fig. 5 · 1.9 Recommended Cable Specifications

The previous table provides a guideline for selecting an appropriate cable type only. Other cable types are also compatible with the system and can be used to achieve the same results.

1.10 Programming and Firmware Download

The AFI5100 is programmed using the host software application via the ACC, or using the FLN Configurator Field Service Tool application. Please refer to the ap- propriate User’s Guide for more Information.

Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are made.

Page 12 of the Siemens AFI5100 user manual — Recommended Cable Specifications
Page 12 · click to enlarge
Page 12

Siemens Building Technologies A24205-A335-B245.doc

Page 13 of the Siemens AFI5100 user manual — Recommended Cable Specifications
Page 13 · click to enlarge
Page 13
Page 13 of the Siemens AFI5100 user manual — Recommended Cable Specifications
Page 14 of the Siemens AFI5100 user manual — Recommended Cable Specifications
Page 14 · click to enlarge
Page 14

© 2005 Copyright by Siemens Building Technologies AG

Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe

Data and design subject to change without notice.

Supply subject to availability.

Printed in the Federal Republic of Germany on environment-friendly chlorine-free paper.

www.sbt.siemens.com

Document no. A24205-A335-B245

Edition 02.2005

Ask about the Siemens AFI5100

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Siemens AFI5100

Be the first to ask — other owners or our team will answer.

Original document

Siemens AFI5100 manual PDF

14 pages·553 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…