Instruction/ maintenance manual of the product MZA 900 P Sennheiser
Go to page of 12
MZA 900 P Bedienungsanleit ung Instructions for use Notice d‘emploi Istruzioni p er l‘uso Instrucciones para el uso Gebruiksaanwijzing MZA 900 P_51 6535_0606_Sp6 .
MZA 900 P_51 6535_0606_Sp6 .book Seite 2 Mit twoch, 12. Jul i 2006 3: 19 15.
1 MZA 900 P The MZA 900 P phanto m powe r adaptor is used to connect pre-polarized cond enser microphones with a 3.5 mm jack plug or a 3-pin special sock et to microphone inputs with 10 – 52 V phant om powering (P12 – P48 ). The connected microphone is supplied via the adaptor.
2 Delivery includes y MZA 900 P with belt clip y Instructions for use y Warranty certificate Connecting the microphone Connect the jack plug of the microphone to the socket of the MZA 900 P. Lock the jack plug by screwing dow n the coupling ring. This prevents accidental loosening of the connection an d annoying noise when the cable is moved.
3 Attaching the MZA 900 P to clothing Using the belt clip, you can unobtrusi vely attach the MZA 900 P to clothing (e.g. belt, waistband). Switchable pre-attenuation The gain can be reduced by 12 dB.
4 Operation and over-modulation indication The MZA 900 P features a two- colour LED. LED lights up in green: The MZA 900 P is properly powered and there is no over- modulation (normal operation).
5 Using the MZA 900 P as a cable tester The MZA 900 P can also be used as a cable tester for XLR microphone cables. For this, there is no need to connect a microph one. Connect one end of the cable to be tested to a mixing console with activated phan tom powering.
6 Pin assignment 1 2 3 MZA 900 P-4 1 2 3 1 2 3 3,5 mm MZA 900 P Kabel XLR-3 F 12 3 1 2 3 XLR-3 M Mikrofon symmetrisch 3,5 mm XLR- 3 M XLR- 3 M + Mikrofon 1 2 3 + front view rear view 3-pin special socket rear view MZA 900 P_51 6535_0606_Sp6 .book Seite 6 Mit twoch, 12.
7 Specifications Frequency response 20–20,000 Hz (–1 dB) Pre-attenuation, switchable 0/–12 dB Roll-off filter, switchable 125 Hz (–3 dB), 12 dB/o ct Max. output voltage at y 0 dB pre-attenuation 1.8 V (P48) 0.6 V (P12) y –12 dB pre-attenuation 0.
8 Manufacturer declarations Wa rr a n t y 2 years Approval Sennheiser electronic GmbH & Co. KG decl are that this device is in compliance with the appl icable CE standards and re gula- tions.
MZA 900 P_51 6535_0606_Sp6 .book Seite 1 Mit twoch, 12. Jul i 2006 3: 19 15.
Sennheiser electronic GmbH & Co. KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ.
An important point after buying a device Sennheiser MZA 900 P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sennheiser MZA 900 P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sennheiser MZA 900 P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sennheiser MZA 900 P you will learn all the available features of the product, as well as information on its operation. The information that you get Sennheiser MZA 900 P will certainly help you make a decision on the purchase.
If you already are a holder of Sennheiser MZA 900 P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sennheiser MZA 900 P.
However, one of the most important roles played by the user manual is to help in solving problems with Sennheiser MZA 900 P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sennheiser MZA 900 P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center