Rangemaster RMDD3604

40 pages·778 KB·Ventilation Hood·PDF·ENDEITNLJA
Rangemaster RMDD3604
Table of Contents 80 sections WARNING READ AND SAVE THESE INSTRUCTIONS · WARNING · CAUTION · NOTE: Model RMDDRBK Remote Up/Down · … ShowHide
Page 1 of the Rangemaster RMDD3604 user manual — NOTE: Model RMDDRBK Remote Up/Down
Page 1 · click to enlarge
Page 1
Rangemaster RMDD3604 — WARNING READ AND SAVE THESE INSTRUCTIONS diagram (page 1)
Fig. 1

MODEL WIDTH BLOWER RMDD3004 30" 500 cfm Interior RMDD3604 36" 500 cfm Interior RMDD4804 48" 500 cfm Interior RMDD3004EX 30" Models 331H, 332H, 335, or 336 Exterior (purchase separately) RMDD3604EX 36" Models 331H, 332H, 335, or 336 Exterior (purchase separately) RMDD4804EX 48" Models 331H, 332H, 335, or 336 Exterior (purchase separately)

WARNING READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce the risk of fire, use only metal ductwork. 8. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches. 9. Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop. 10.Children should not be left alone or unattended in the area where this appliance is in use. 11. This unit must be grounded.

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immedi ately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you

already know how to operate it. B. The fire is small and contained in the area where it

started. C. The fire department is being called. D. You can fight the fire with your back to an exit.

a Based on “Kitchen Firesafety Tips” published by NFPA.

!

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Clean filters and grease-laden surfaces frequently. 4. Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician. 5. Please read specification label on product for further informa- tion and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings.

NOTE: Model RMDDRBK Remote Up/Down

Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when

Control sold separately.

cooking flaming foods. c) Clean ventilating fans frequently. Grease should not be

allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate

INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.

for the size of the surface element.

Page 2 of the Rangemaster RMDD3604 user manual — TAKE MEASUREMENTS
Page 2 · click to enlarge
Page 2

PLANNING

Interior Blower Installation Exterior Blower Installation

This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, penin- sula, or conventional wall loca- tions.

TYPICAL INSTALLATION

This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, penin- sula, or conventional wall lo- cations.

TYPICAL INSTALLATION

COUNTER TOP

CHIMNEY TOP

COUNTER TOP

CHIMNEY TOP

Rangemaster RMDD3604 — TYPICAL INSTALLATION diagram (page 2)
Fig. 2

COOK TOP

COOK TOP

AIR VENT

AIR VENT

GEAR MOTOR COVER

GEAR MOTOR COVER

  • This unit can be easily installed following these basic steps:
  • Cut out the countertop opening.
  • Mount the unit in the cabinet.
  • Connect the ductwork and electrical.
  • Install the cooktop. Note: the high level of air flow of this appliance may effect the gas flame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower.
  • This unit can be easily installed following these basic steps:
  • Cut out the countertop opening.
  • Mount the unit in the cabinet.
  • Install Model 331H, 332H, 335, or 336 External Blower
  • Connect the ductwork and electrical.
  • Install the cooktop.

BOX

BOX

120 VAC GROUNDED OUTLET

120 VAC GROUNDED OUTLET

3-1/4" X 14" DUCT CONNECTOR

3-1/4" X 10" DUCT CONNECTOR

ELECTRICAL SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

  • 120 VAC
  • 60 Hz
  • 4.0 A
  • 120 VAC
  • 60 Hz
  • 6.0 A (max.)

TAKE MEASUREMENTS

Rangemaster RMDD3604 — TAKE MEASUREMENTS diagram (page 2)
Fig. 3
1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. Models RMDD3004 & RMDD3004EX will fit in most 30" wide cabinets. Models RMDD3604 & RMDD3604EX will fit in most 36" wide cabinets. Models RMDD4804 & RMDD4804EX will fit in most 48" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation.
2. Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.

Pay special attention to the areas of potential interference high- lighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back.

Page 3 of the Rangemaster RMDD3604 user manual — RIGHT DISCHARGE
Page 3 · click to enlarge
Page 3

TAKE MEASUREMENTS (CONTINUED)

Rangemaster RMDD3604 — TAKE MEASUREMENTS (CONTINUED) diagram (page 3)
Fig. 4

PLAN THE DUCTWORK

Interior Blower Installation Exterior Blower Installation

LEFT DISCHARGE

LEFT DISCHARGE

1. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are available with side-toside adjustment for accurate alignment of ductwork. 2. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of
Rangemaster RMDD3604 — LEFT DISCHARGE diagram (page 3)
Fig. 5
1. The exterior downdraft blower system is designed for use with 3-1/4" x 14" ductwork (can be transitioned to 8" round). Three different discharge directions are available with sideto-side adjustment for accurate alignment of ductwork. 2. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum

RIGHT DISCHARGE

RIGHT DISCHARGE

DOWN DISCHARGE

DOWN DISCHARGE

elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interfer- ence.

number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference.

Rangemaster RMDD3604 — RIGHT DISCHARGE diagram (page 3)
Fig. 6
Rangemaster RMDD3604 — RIGHT DISCHARGE diagram (page 3)
Fig. 7
3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.
3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.
Page 4 of the Rangemaster RMDD3604 user manual — EXTERIOR
Page 4 · click to enlarge
Page 4

PLAN THE CABINET CUTOUTS

Rangemaster RMDD3604 — PLAN THE CABINET CUTOUTS diagram (page 4)
Fig. 8
! CAUTIONBEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor

10¼" x 3½" CUTOUT (14¼" x 3½" FOR EXTERIOR

16 3/8" (21½" FOR EXTERIOR BLOWER)

EXTERIOR

Page 5 of the Rangemaster RMDD3604 user manual — BOTTOM
Page 5 · click to enlarge
Page 5

PLAN THE WIRING

Interior Blower Installation Exterior Blower Installation

1. The Interior Downdraft Blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit. 2. The unit has a 18 in. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.
1. The Exterior Downdraft Blower system draws 6 AMPS and requires a 120 VAC, 60 Hz circuit. 2. The unit has a 18 in. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.

or Model RMDD3604 is being installed in a 36" wide cabinet...

or Model RMDD3604EX is being installed in a 36" wide cabinet...

or Model RMDD4804 is being installed in a 48" wide cabinet...

or Model RMDD4804EX is being installed in a 48" wide cabinet...

...the outlet cannot be located on the back wall of cabinet.

...the outlet cannot be located on the back wall of cabinet.

  • In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:
  • mount the electrical box to a side wall or cabinet floor - at least 12 inches from the back wall.
  • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft. Then provide a clearance hole in the back wall of the cabinet.
  • In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:
  • mount the electrical box to a side wall or cabinet floor - at least 12 inches from the back wall.
  • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft. Then provide a clearance hole in the back wall of the cabinet.

PREPARE THE DOWNDRAFT

Interior/Exterior Blower Duct Connection Installation

3¼" X 10" DISCHARGE (3¼" X 14" FOR EXTERIOR BLOWER)

The downdraft is shipped with duct connector pointing toward the bottom of the unit. If you wish to change this orientation, follow the steps below:

1. Place the downdraft on its back on a table of flat work surface.

NUTS

2. Remove the 4 nuts and 2 clamp channels .
3. Remove 2 screws and the gear motor cover .

CLAMP CHANNELS

4. Carefully position the blower under the bottom flange of the downdraft with the 3¼" x 10" discharge (3¼" x 14" for exterior blower) pointed in the desired direction.

SCREWS

5. Connect motor plug .

COVER

MOTOR

PLATE

6. Replace the gear motor cover and 2 sheet metal screws.

GEARMOTOR

COVER

PLUG

7. Replace the 2 clamp channels and start the 4 nuts, do not tighten.

ADDITIONAL

SCREWS

8. Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom flange to secure bottom in blower.

BOTTOM

FLANGE

Page 6 of the Rangemaster RMDD3604 user manual — CUT COUNTERTOP OPENING
Page 6 · click to enlarge
Page 6

CUT COUNTERTOP OPENING

1. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it.
2. Set cooktop in place and slide it as far forward as possible. Center and square it with edges of countertop.
Rangemaster RMDD3604 — CUT COUNTERTOP OPENING diagram (page 6)
Fig. 9
3. Place the plastic template against the back flange of the cooktop and center it. Trace around template to mark the downdraft opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of countertop.
Page 7 of the Rangemaster RMDD3604 user manual — 8" RD. ELBOW & DUCTWORK
Page 7 · click to enlarge
Page 7

MOUNTING SCREWS MOUNT THE UNIT

Rangemaster RMDD3604 — MOUNTING SCREWS MOUNT THE UNIT diagram (page 7)
Fig. 10

LEVELING BRACKET - FLANGE FACING OUT

1. Set downdraft into opening. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tightening the two mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops.

LEVELING BRACKET -

FLANGE FACING IN

3. Screw leveling brackets to bottom of cabinet. Tighten screws holding leveling bracket to unit on each side.

INSTALL DUCTWORK

Blower Installation

Rangemaster RMDD3604 — INSTALL DUCTWORK diagram (page 7)
Fig. 11
! CAUTIONBEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor

joists, wall studs, electrical

3¼" X 10" TO 6" RD. TRANSITION (3¼" X 14" TO 8" RD. TRANSITION

wiring, or plumbing.

COLLAR SCREWS

1. Cut hole in cabinet as well as holes in wall or floor as necessary.

FOR EXTERIOR

2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight.

8" RD. ELBOW & DUCTWORK

3. Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Retighten screws and nuts.

ç BLOWER è

Page 8 of the Rangemaster RMDD3604 user manual — COOKTOP
Page 8 · click to enlarge
Page 8

INSTALL ELECTRICAL WIRING

Interior Blower Installation

Exterior Blower Installation

!

!

1. Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft's power cord can easily reach it.
1. Mount a standard wiring box, with 3-pronged grounded receptacle, inside the kitchen cabinet. Make sure the unit's power cord can easily reach it.
2. Run appropriate power cable into cabinet and connect it to receptacle.
2. Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle.
3. Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.
3. Exterior blower may not exceed 6.0 Amp rating.
4. Run 2-wire plus ground power cable from the remote blower to wiring box on 10" round discharge plate.
5. Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire.
6. Replace wiring box cover.
7. Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

INSTALL COOKTOP

1. Align the cooktop with the downdraft and fasten cooktop in place.

COOKTOP

UP / DOWN

CONTROL

COUNTERTOP

The downdraft up/down control must be mounted into the countertop, at least 4" from the cooktop.

Page 9 of the Rangemaster RMDD3604 user manual — CABINET
Page 9 · click to enlarge
Page 9

REMOTE UP/DOWN CONTROL INSTALLATION (OPTIONAL)

When to use the Remote UP/DOWN Control The Remote UP/DOWN Control should be used when your cooktop has a burner that is within 4 inches of the UP/DOWN Button on the downdraft chimney. The Remote UP/DOWN Control can be used for convenient UP/ DOWN operation of the downdraft chimney (even when a burner is more than 4 inches from the UP/DOWN Button of the downdraft chimney).

How to use the Remote UP/DOWN Control Do not place the remote control where it will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control. The Remote UP/DOWN Control disables the UP/DOWN function of the UP/DOWN Button on the downdraft chimney.

.625 .625

Installation 1. Using the template at right, lay out the 3-hole pattern on the counter top. Mark the centers of the three holes to be drilled. 2. Carefully drill the three holes through the counter top. Be careful not to damage or chip the counter top surface when drilling the holes. 3. Remove the control from the plastic bag. Line the control up with the three holes and position the control so it is parallel with the front of the counter top. 4. Remove the two nylon thumbnuts from the plastic bag and thread onto the two studs on the control from below the counter top. Hand tighten only.

.250 DIA.

HOLES

.438 DIA. HOLE

CUT OUT ON DOTTED LINE

CUT OUT ON DOTTED LINE

5. Remove the blower, clamp channels, and gearmotor cover from downdraft (see"Prepare the Downdraft" on page 5). Remove the large panel to expose the downdraft's wiring.
Rangemaster RMDD3604 — CUT OUT ON DOTTED LINE diagram (page 9)
Fig. 12

WIRING

Rangemaster RMDD3604 — WIRING diagram (page 9)
Fig. 13

BOX

WIRING

BOX

REMOTE

CABLE

LOWER

RIGHT

SIDE

OF DOWNDRAFT

7. Remove remote cable from the plastic bag and plug into back of control from below counter top. Route cable through cabinet to lower right hand corner of downdraft and through the clearance holes in the side of downdraft and wiring box. Plug cable into circuit board plug, as shown. 8. Stuff excess cable out of the way, secure the cable so it is not damaged by items stored in the cabinet, and reassemble downdraft.

CABINET

FLOOR

6. At the lower right hand corner of downdraft, unplug the cable from the left side of the wiring box.
Page 10 of the Rangemaster RMDD3604 user manual — BACKSIDE OF REMOTE SWITCH
Page 10 · click to enlarge
Page 10

USE AND CARE

Cleaning

Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water.

Wash the 2 aluminum/stainless steel grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter.

Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter. The activating switch is pressed and the air vent rises.

Servicing

It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism.

Disconnect power to the cooktop and remove it first. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet.

BACKSIDE OF REMOTE SWITCH

TEMPLATE

Page 11 of the Rangemaster RMDD3604 user manual — KNOB
Page 11 · click to enlarge
Page 11

OPERATION

Rangemaster RMDD3604 — OPERATION diagram (page 11)
Fig. 14
Rangemaster RMDD3604 — OPERATION diagram (page 11)
Fig. 15

Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut OFF.

Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise.

Rangemaster RMDD3604 — OPERATION diagram (page 11)
Fig. 16

Heat Sentry

When chimney is UP and blower is ON (at any speed) or OFF:

KNOB

If the exhaust temperature becomes higher than expected, the Heat Sentry mode will activate and increase the blower speed to HIGH.

Lowering the chimney will turn blower OFF - even if Heat Sentry is active.

The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent.

Page 12 of the Rangemaster RMDD3604 user manual — SERVICE PARTS WARRANTY
Page 12 · click to enlarge
Page 12

SERVICE PARTS WARRANTY

BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, IN- CLUDING, BUT NOT LIMITED TO, IMPLIED WARRAN- TIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

KEY 30N 36N 48N NO. WIDTH WIDTH WIDTH DESCRIPTION

1 97015987 97015988 97015989 TOP COVER 2 99140195 99140195 99140195 FILTER SPRING 3 99230345 99230345 99230345 POP RIVET 4 97015970 97015971 97015972 CHIMNEY WELDMENT 5 97015874 97015874 97015874 END CAP RH 6 98009358 98009358 98009358 END CAP LR 7 97015973 97015973 97015973 MACHINED CHIMNEY SLIDE 8 98010013 98010013 98010013 MACHINED AIRBOX SLIDE 9 99160421 99160421 99160421 SCREW RHM 8-32 x .375 10 99160419 99160419 99160419 SCREW 8-32 x ..500 PHL 11 99271218 99271218 99271218 GROUND WIRE 12 99150471 99150471 99150471 SCREW 10-32 x .500 TYP CA PH 13 97015841 97015842 97015843 FILTER 14 99710032 99710032 99710032 SPACER 15 99111184 99111184 99111184 SLIDE STRIPS 16 97015974 97015975 97015976 AIRBOX WELDMENT 17 99271210 99271210 99271210 CORD SET 18 99400060 99400060 99400060 STRAIN RELIEF BUSHING 19 99271295 99271295 99271295 WIRE HARNESS 20 99271292 99271292 99271292 POT ASSEMBLY 21 99271291 99271291 99271291 CONTROL BOARD 22 97015674 97015674 97015674 CRANK ASSEMBLY 23 97015977 97015977 97015977 GEAR MOTOR BRACKET 24 99080513 99080542 99080542 GEAR MOTOR 26 98009802 98009801 98009800 FRONT AIRBOX BOTTOM 27 97015990 97015991 97015992 GEAR MOTOR COVER INTERNAL BLOWER MODELS 97015993 97015994 97015995 GEAR MOTOR COVER EXTERNAL BLOWER MODELS 28 98008158 98008158 98008158 AIRBOX OPENING COVER 29 98009773 98009773 98009773 AIRBOX CLAMP 30 99260488 99260488 99260488 WHIZ NUT 10-24 31 97015700 97015700 97015700 SCROLL BOX ASSEMBLY 32 98008150 98008150 98008150 SCROLL BOX COVER 33 98008157 98008157 98008157 CAPACITOR CLAMP 34 98008167 98008167 98008167 EXT - SCROLL BOX WELDMENT 35 99080362 99080362 99080362 MOTOR W/CAPACITOR 36 99020247 99020247 99020247 BLOWER WHEEL 37 99100484 99100484 99100484 MOTOR MOUNT ISOLATOR 38 99260477 99260477 99260477 WHIZ NUT 1/4-20 39 99030323 99030323 99030323 THERMOSTAT 40 97015903 97015903 97015903 ADAPTOR PLATE 41 98010005 98010005 98010005 OUTLET PLATE 42 99271304 99271304 99271304 WIRE HARNESS 43 99400042 99400042 99400042 STRAIN RELIEF BUSHING 44 99271296 99271296 99271296 UP/DOWN BUTTON HARNESS 45 99271306 99271306 99271306 THERMOSTAT WIRE HARNESS 46 98010010 98010010 98010010 THERMOSTAT MOUNTING BRACKET

During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUO- RESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR- RANTY. BROAN SHALL NOT BE LIABLE FOR INCI- DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PROD- UCT USE OR PERFORMANCE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evi- dence of the original purchase date.

Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 (1-800-637-1453)

Page 13 of the Rangemaster RMDD3604 user manual — SERVICE PARTS
Page 13 · click to enlarge
Page 13

SERVICE PARTS

Rangemaster RMDD3604 — SERVICE PARTS diagram (page 13)
Fig. 17

Ask about the Rangemaster RMDD3604

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Rangemaster RMDD3604

Be the first to ask — other owners or our team will answer.

Original document

Rangemaster RMDD3604 manual PDF

40 pages·778 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…