MODEL WIDTH BLOWER RMDD3004 30" 500 cfm Interior RMDD3604 36" 500 cfm Interior RMDD4804 48" 500 cfm Interior RMDD3004EX 30" Models 331H, 332H, 335, or 336 Exterior (purchase separately) RMDD3604EX 36" Models 331H, 332H, 335, or 336 Exterior (purchase separately) RMDD4804EX 48" Models 331H, 332H, 335, or 336 Exterior (purchase separately)
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce the risk of fire, use only metal ductwork. 8. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches. 9. Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop. 10.Children should not be left alone or unattended in the area where this appliance is in use. 11. This unit must be grounded.
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immedi ately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you
already know how to operate it. B. The fire is small and contained in the area where it
started. C. The fire department is being called. D. You can fight the fire with your back to an exit.
a Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Clean filters and grease-laden surfaces frequently. 4. Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician. 5. Please read specification label on product for further informa- tion and requirements.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when
Control sold separately.
cooking flaming foods. c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate
INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.
for the size of the surface element.

Interior Blower Installation Exterior Blower Installation
This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, penin- sula, or conventional wall loca- tions.
This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, penin- sula, or conventional wall lo- cations.
COUNTER TOP
CHIMNEY TOP
COUNTER TOP
CHIMNEY TOP

COOK TOP
AIR VENT
AIR VENT
GEAR MOTOR COVER
GEAR MOTOR COVER
BOX
120 VAC GROUNDED OUTLET
120 VAC GROUNDED OUTLET
3-1/4" X 14" DUCT CONNECTOR
3-1/4" X 10" DUCT CONNECTOR
ELECTRICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS

Pay special attention to the areas of potential interference high- lighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back.


Interior Blower Installation Exterior Blower Installation
LEFT DISCHARGE

RIGHT DISCHARGE
DOWN DISCHARGE
DOWN DISCHARGE
elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interfer- ence.
number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference.




10¼" x 3½" CUTOUT (14¼" x 3½" FOR EXTERIOR
16 3/8" (21½" FOR EXTERIOR BLOWER)

Interior Blower Installation Exterior Blower Installation
or Model RMDD3604 is being installed in a 36" wide cabinet...
or Model RMDD3604EX is being installed in a 36" wide cabinet...
or Model RMDD4804 is being installed in a 48" wide cabinet...
or Model RMDD4804EX is being installed in a 48" wide cabinet...
...the outlet cannot be located on the back wall of cabinet.
...the outlet cannot be located on the back wall of cabinet.
Interior/Exterior Blower Duct Connection Installation
3¼" X 10" DISCHARGE (3¼" X 14" FOR EXTERIOR BLOWER)
The downdraft is shipped with duct connector pointing toward the bottom of the unit. If you wish to change this orientation, follow the steps below:
MOTOR
PLATE
COVER
PLUG
SCREWS
FLANGE




FLANGE FACING IN
Blower Installation

joists, wall studs, electrical
3¼" X 10" TO 6" RD. TRANSITION (3¼" X 14" TO 8" RD. TRANSITION
wiring, or plumbing.
ç BLOWER è

Interior Blower Installation
Exterior Blower Installation
!
!
UP / DOWN
CONTROL
COUNTERTOP
The downdraft up/down control must be mounted into the countertop, at least 4" from the cooktop.

When to use the Remote UP/DOWN Control The Remote UP/DOWN Control should be used when your cooktop has a burner that is within 4 inches of the UP/DOWN Button on the downdraft chimney. The Remote UP/DOWN Control can be used for convenient UP/ DOWN operation of the downdraft chimney (even when a burner is more than 4 inches from the UP/DOWN Button of the downdraft chimney).
How to use the Remote UP/DOWN Control Do not place the remote control where it will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control. The Remote UP/DOWN Control disables the UP/DOWN function of the UP/DOWN Button on the downdraft chimney.
Installation 1. Using the template at right, lay out the 3-hole pattern on the counter top. Mark the centers of the three holes to be drilled. 2. Carefully drill the three holes through the counter top. Be careful not to damage or chip the counter top surface when drilling the holes. 3. Remove the control from the plastic bag. Line the control up with the three holes and position the control so it is parallel with the front of the counter top. 4. Remove the two nylon thumbnuts from the plastic bag and thread onto the two studs on the control from below the counter top. Hand tighten only.
.250 DIA.
.438 DIA. HOLE


WIRING
BOX
REMOTE
CABLE
LOWER
RIGHT
SIDE
OF DOWNDRAFT
FLOOR

Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water.
Wash the 2 aluminum/stainless steel grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter.
Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter. The activating switch is pressed and the air vent rises.
It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism.
Disconnect power to the cooktop and remove it first. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet.
TEMPLATE



Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut OFF.
Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise.

When chimney is UP and blower is ON (at any speed) or OFF:
If the exhaust temperature becomes higher than expected, the Heat Sentry mode will activate and increase the blower speed to HIGH.
Lowering the chimney will turn blower OFF - even if Heat Sentry is active.
The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent.

BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, IN- CLUDING, BUT NOT LIMITED TO, IMPLIED WARRAN- TIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
KEY 30N 36N 48N NO. WIDTH WIDTH WIDTH DESCRIPTION
1 97015987 97015988 97015989 TOP COVER 2 99140195 99140195 99140195 FILTER SPRING 3 99230345 99230345 99230345 POP RIVET 4 97015970 97015971 97015972 CHIMNEY WELDMENT 5 97015874 97015874 97015874 END CAP RH 6 98009358 98009358 98009358 END CAP LR 7 97015973 97015973 97015973 MACHINED CHIMNEY SLIDE 8 98010013 98010013 98010013 MACHINED AIRBOX SLIDE 9 99160421 99160421 99160421 SCREW RHM 8-32 x .375 10 99160419 99160419 99160419 SCREW 8-32 x ..500 PHL 11 99271218 99271218 99271218 GROUND WIRE 12 99150471 99150471 99150471 SCREW 10-32 x .500 TYP CA PH 13 97015841 97015842 97015843 FILTER 14 99710032 99710032 99710032 SPACER 15 99111184 99111184 99111184 SLIDE STRIPS 16 97015974 97015975 97015976 AIRBOX WELDMENT 17 99271210 99271210 99271210 CORD SET 18 99400060 99400060 99400060 STRAIN RELIEF BUSHING 19 99271295 99271295 99271295 WIRE HARNESS 20 99271292 99271292 99271292 POT ASSEMBLY 21 99271291 99271291 99271291 CONTROL BOARD 22 97015674 97015674 97015674 CRANK ASSEMBLY 23 97015977 97015977 97015977 GEAR MOTOR BRACKET 24 99080513 99080542 99080542 GEAR MOTOR 26 98009802 98009801 98009800 FRONT AIRBOX BOTTOM 27 97015990 97015991 97015992 GEAR MOTOR COVER INTERNAL BLOWER MODELS 97015993 97015994 97015995 GEAR MOTOR COVER EXTERNAL BLOWER MODELS 28 98008158 98008158 98008158 AIRBOX OPENING COVER 29 98009773 98009773 98009773 AIRBOX CLAMP 30 99260488 99260488 99260488 WHIZ NUT 10-24 31 97015700 97015700 97015700 SCROLL BOX ASSEMBLY 32 98008150 98008150 98008150 SCROLL BOX COVER 33 98008157 98008157 98008157 CAPACITOR CLAMP 34 98008167 98008167 98008167 EXT - SCROLL BOX WELDMENT 35 99080362 99080362 99080362 MOTOR W/CAPACITOR 36 99020247 99020247 99020247 BLOWER WHEEL 37 99100484 99100484 99100484 MOTOR MOUNT ISOLATOR 38 99260477 99260477 99260477 WHIZ NUT 1/4-20 39 99030323 99030323 99030323 THERMOSTAT 40 97015903 97015903 97015903 ADAPTOR PLATE 41 98010005 98010005 98010005 OUTLET PLATE 42 99271304 99271304 99271304 WIRE HARNESS 43 99400042 99400042 99400042 STRAIN RELIEF BUSHING 44 99271296 99271296 99271296 UP/DOWN BUTTON HARNESS 45 99271306 99271306 99271306 THERMOSTAT WIRE HARNESS 46 98010010 98010010 98010010 THERMOSTAT MOUNTING BRACKET
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUO- RESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR- RANTY. BROAN SHALL NOT BE LIABLE FOR INCI- DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PROD- UCT USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evi- dence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 (1-800-637-1453)


Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.