EN
Rangemaster logo
Official user manual

Rangemaster E6448SS

48 pages·4.9 MB·Ventilation Hood·PDF·ENDEITNLJA
Rangemaster E6448SS
Table of Contents 73 sections INSTALLATION INSTRUCTIONS · REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register · SV08341 rev. D · ! ! · … ShowHide
INSTALLATION INSTRUCTIONSp.1REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/registerp.1SV08341 rev. Dp.1! !p.2WARNING WARNINGp.2CAUTIONp.2TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:p.2- E64000 SERIES RANGE HOOD SYSTEM -p.3INTERNAL BLOWERSp.3IN-LINE AND EXTERIOR BLOWERSp.4HL0098p.41. SELECT BLOWER OPTION AND INSTALLATION TYPEp.53¼” x 10” duct or 7” or 8” round ductp.5SINGLE INTERNAL BLOWERp.5DOUBLE INTERNAL BLOWERSp.5TYPICAL DUCTWORKp.5MODEL 331H, 332H, 335 OR 336p.5MODEL HLB3, HLB6, HLB9 OR HLB11 IN-LINE BLOWER TYPICAL DUCTWORKp.5EXTERIOR BLOWER TYPICAL DUCTWORKp.52. PREPARE THE INSTALLATIONp.6A A 10”p.6HD0285Ap.62. PREPARE THE INSTALLATION (CONT’D)p.7D UCTED INSTALLATIONS ONLYp.73. INSTALL BACKSPLASH (OPTIONAL)p.74. REMOVE FILTERS AND GREASE DRIP RAILp.85. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)p.8S INGLE BLOWER HOODp.8D OUBLE BLOWER HOODp.86. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)p.9V ERTICAL DISCHARGEp.9H ORIZONTAL DISCHARGEp.97. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY)p.98. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)p.10(INTERNAL BLOWER HOOD ONLY)p.109. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)p.1010. INSTALL THE HOOD (ALL BLOWERS)p.1111. CONNECT WIRING (ALL BLOWERS)p.11HE0088p.1112. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER HOOD)p.1113. INSTALL LIGHT BULBSp.1214. REINSTALL GREASE DRIP RAIL AND FILTERSp.1215. USE AND CAREp.13Avoid: When choosing a detergentp.1316. OPERATIONp.13HEAT SENTRY™p.1316. OPERATION (CONT’D)p.1417. WARRANTYp.14WARRANTYp.1418. WIRING DIAGRAMSp.15NEONp.15Broan Elite E64000 Series Exterior or In-Line blower hoodsp.1519. SERVICE PARTSp.16Broan Elite E64000 Series Internal blower hoodsp.16HL0104p.16HL0103p.16K EYp.16P ARTp.161 SV13296p.16SV17797p.16SV17640 SV17641 SV17642 SV17643p.1613 SV17600 SV17603p.16* SV08353p.16GUIDE D’INSTALLATIONp.17ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.broan.com/registerp.17SV08341 rév. Dp.17- SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE E64000 -p.19VENTILATEURS INTÉRIEURSp.19VENTILATEURS EN LIGNE ET EXTÉRIEURSp.20M ODÈLE 437 (C APUCHON DE TOITp.20DOSSERET SÉRIE RMP (R ECOUVREMENT DE MURp.20EN ACIER INOXYDABLE AVECp.20O PTIONNEL )p.20
Page 1 of the Rangemaster E6448SS user manual — Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
Page 1 · click to enlarge
Page 1

INSTALLATION INSTRUCTIONS

Rangemaster E6448SS — INSTALLATION INSTRUCTIONS diagram (page 1)
Fig. 1

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.

Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119

REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register

SV08341 rev. D

Page 2 of the Rangemaster E6448SS user manual — TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
Page 2 · click to enlarge
Page 2

! !

WARNING WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN – You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion. 4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you know

2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

how to operate it. B. The fire is small and contained in the area where

it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

CAUTION

1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced. 5. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 24’’ and at a maximum of 30” above the cooking surface. 6. Two installers are recommended because of the large size and weight of this hood. 7. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage. 8. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 9. Because of the high exhausting capacity of this hood, you should make sure enough air is entering the house to replace exhausted air. Use an appropriate make-up air device or open a window close to or in the kitchen. 10. To reduce the risk of fire and electric shock, the Broan Elite E64E Series hood must be installed with one Broan exterior blower model 331H, 332H, 335 or 336; or one Broan in-line blower models HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Exterior or in-line blowers are sold separately.) 11. Please read specification label on product for further information and requirements.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filters.

d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

Page 3 of the Rangemaster E6448SS user manual — - E64000 SERIES RANGE HOOD SYSTEM -
Page 3 · click to enlarge
Page 3

- E64000 SERIES RANGE HOOD SYSTEM -

INTERNAL BLOWERS

Rangemaster E6448SS — - E64000 SERIES RANGE HOOD SYSTEM - diagram (page 3)
Fig. 2

MODEL 437 (HIGH CAPACITY ROOF CAP)

(7” ROUND WALL CAP) MODEL 634

MODEL 418 (10” ROUND ADJUSTABLE ELBOW)

MODEL 407 (7” ROUND - 2 FT. SECTIONS)

IN-LINE DAMPER MODEL 639

MODEL 413 TRANSITION (3¼” X 10” TO 8”)

MODEL 410 (10” ROUND DUCT—2 FT. SECTIONS)

MODEL 427 (4½” X 18½” TO 10” ROUND, 6” HIGH - LATERAL

MODEL 423 (4½” X 18½” TO 10” ROUND -

MODEL 424 (4½” X 18½” TO 10” ROUND - HORIZ.

MODEL 454 (4½” X 18½” TO 10” ROUND -

MODEL 453 (4½” X 18½” TO 10” ROUND -

ADAPTER /DAMPER 3¼’’ X 10’’ (SUPPLIED WITH SINGLE BLOWER HOOD) ADAPTER 4½” X 18½”

RMP SERIES BACKSPLASH (STAINLESS STEEL WALL COVERING

Page 4 of the Rangemaster E6448SS user manual — HL0098
Page 4 · click to enlarge
Page 4

- E64000 SERIES RANGE HOOD SYSTEM -

IN-LINE AND EXTERIOR BLOWERS

Rangemaster E6448SS — - E64000 SERIES RANGE HOOD SYSTEM - diagram (page 4)
Fig. 3

MODEL 437 (HIGH CAPACITY ROOF CAP)

IN-LINE BLOWER (INCLUDES TWO 8” X 12” TO

MODEL 441 (10” ROUND WALL CAP)

MODEL 643 (8” ROUND WALL CAP)

IN-LINE BLOWER (INCLUDES TWO 4½” X 18½” TO

MODEL 421 (10” ROUND. VERT. IN-LINE DAMPER) RECOMMENDED FOR USE WITH EXTERIOR BLOWERS

10” ROUND ADJUSTABLE ELBOW MODEL HLB3 (280 CFM)

IN-LINE BLOWER (INCLUDES ONE 8” TO 10”

MODEL 410 (10” ROUND DUCT - 2 FT. SECTIONS)

332KR IN-LINE AND EXTERIOR BLOWER ROUGH-IN KIT (SUPPLIED WITH HOOD)

RMP SERIES BACKSPLASH (STAINLESS STEEL WALL COVERING WITH WARMING SHELVES. OPTIONAL)

HL0098

Page 5 of the Rangemaster E6448SS user manual — MODEL 331H, 332H, 335 OR 336
Page 5 · click to enlarge
Page 5

1. SELECT BLOWER OPTION AND INSTALLATION TYPE

1.1 NON-DUCTED INSTALLATION For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series.

1.2 DUCTED INSTALLATION The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers (included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed. If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 10 and up of this manual. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10” round ducts, use a transition (internal blower(s) only). Use 2” duct tape to seal duct joints. The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion.

Rangemaster E6448SS — 1. SELECT BLOWER OPTION AND INSTALLATION TYPE diagram (page 5)
Fig. 4
Rangemaster E6448SS — 1. SELECT BLOWER OPTION AND INSTALLATION TYPE diagram (page 5)
Fig. 5

3¼” x 10” duct or 7” or 8” round duct

3¼” x 10” to 7” or 3¼” x 10” to 8” transition (if using round duct)

SINGLE INTERNAL BLOWER

DOUBLE INTERNAL BLOWERS

TYPICAL DUCTWORK

TYPICAL DUCTWORK

Rangemaster E6448SS — SINGLE INTERNAL BLOWER diagram (page 5)
Fig. 6
Rangemaster E6448SS — SINGLE INTERNAL BLOWER diagram (page 5)
Fig. 7

MODEL 331H, 332H, 335 OR 336

MODEL HLB3, HLB6, HLB9 OR HLB11 IN-LINE BLOWER TYPICAL DUCTWORK

EXTERIOR BLOWER TYPICAL DUCTWORK

Page 6 of the Rangemaster E6448SS user manual — A A 10”
Page 6 · click to enlarge
Page 6

2. PREPARE THE INSTALLATION

Make sure that the following items are included:

- Range hood - Accessories:

  • Baffle filters
  • Baffle filters handles (located inside the hood)
  • 3¼” x 10” adapter/damper (located inside internal single blower hood)
  • 4½” x 18½” adapter (screwed inside internal double blower hood)
  • In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
  • Bag of parts including: (1) wire clamp, (9) no. 8 x 1/2”, (2) wire connectors, (8) no. 8-32 x 1/4” screws, (4) no. 8 x 3/8” screws Parts sold separately:

- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition) - Exterior blower assembly 331H, 332H, 335 or 336 - Shielded halogen lights (120 V, 50 W, GU-10) (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width) - RMP Series Backsplash (optional) - ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only) - Transitions, duct, elbows, dampers, wall or roof cap

Refer to pages 3 and 4 for a complete list of venting options and model numbers. NOTES: 1. For cabinets with recessed bottom, attach three wood filler strips cut to length (not included), on each side, as

shown below. See illustration and table below for wood filler strips location. 2. For hoods with external or in-line blowers, do not install the transverse wood filler strip.

HOOD WIDTHSCENTER OF WOOD STRIP LOCATION (A) 30’’133⁄” 8 36’’163⁄” 8 42’’193⁄” 8 48’’223⁄” 8

A A 10”

HD0285A

Page 7 of the Rangemaster E6448SS user manual — 3. INSTALL BACKSPLASH (OPTIONAL)
Page 7 · click to enlarge
Page 7

2. PREPARE THE INSTALLATION (CONT’D)

D UCTED INSTALLATIONS ONLY

Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal).

Rangemaster E6448SS — D UCTED INSTALLATIONS ONLY diagram (page 7)
Fig. 8
HOOD WIDTHSDIMENSION C 30’’13” 36’’16” 42’’19”
HOOD WIDTHSDIMENSION C 30’’13” 36’’16” 42’’19” 48’’22”

3. INSTALL BACKSPLASH (OPTIONAL)

Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.)

Page 8 of the Rangemaster E6448SS user manual — D OUBLE BLOWER HOOD
Page 8 · click to enlarge
Page 8

4. REMOVE FILTERS AND GREASE DRIP RAIL

Rangemaster E6448SS — 4. REMOVE FILTERS AND GREASE DRIP RAIL diagram (page 8)
Fig. 9

Remove filters from hood and set aside. NOTE: It is recommended to start with the center one(s).

B. Remove tape on grease drip rail (1).

5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)

S INGLE BLOWER HOOD

Rangemaster E6448SS — S INGLE BLOWER HOOD diagram (page 8)
Fig. 10

Remove both screws retaining the adapter/damper (1) from inner top of the hood.

D OUBLE BLOWER HOOD

Rangemaster E6448SS — D OUBLE BLOWER HOOD diagram (page 8)
Fig. 11

First unplug both blower motors (1) before removing 3 screws retaining the adapter (2) from inner top of the hood.

Fold the adapter and insert the male part (grey section shown in inset) into the female part (white section shown in the inset). Then, fold over each male and female end to finalize assembling the adapter.

Page 9 of the Rangemaster E6448SS user manual — 7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY)
Page 9 · click to enlarge
Page 9

6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)

Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.

Rangemaster E6448SS — 6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY) diagram (page 9)
Fig. 12

V ERTICAL DISCHARGE

H ORIZONTAL DISCHARGE

Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag). NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).

7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY)

All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the back panel of the hood. The procedure below applies for one or two motors.

Rangemaster E6448SS — 7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY) diagram (page 9)
Fig. 13

Unplug the blower.

Using a 5/16” socket, remove all blower mounting screws from the inner top of the hood. Keep the screws for further use.

Page 10 of the Rangemaster E6448SS user manual — 9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)
Page 10 · click to enlarge
Page 10

7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY)

Rangemaster E6448SS — 7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY) diagram (page 10)
Fig. 14

Slide the blower to disengage its flange from the retaining bracket.

Flip the blower and engage its flange in the back wall retaining bracket. Using a 5/16” socket and the screws previously removed, secure the blower to the hood.

Plug the blower in. NOTE FOR DUAL BLOWER HOOD ONLY: Cut off the plastic tie wrap on left motor cable.

8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)

(INTERNAL BLOWER HOOD ONLY)

Rangemaster E6448SS — 8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE) diagram (page 10)
Fig. 15

Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10” adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install an appropriate sized transition and seal the joints with duct tape.

9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)

Refer to the installation sheet included with the recirculation kit for details.

Page 11 of the Rangemaster E6448SS user manual — HE0088
Page 11 · click to enlarge
Page 11

10. INSTALL THE HOOD (ALL BLOWERS)

INTERNAL BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions, leaving a 1/8” gap. Remove wiring cover. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it into position. Make sure the adapter (or the transition) enters the ducting. Secure the hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].

Rangemaster E6448SS — 10. INSTALL THE HOOD (ALL BLOWERS) diagram (page 11)
Fig. 16

EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions, leaving a 1/8” gap. Remove wiring cover on top of the hood, punch-out the electrical knock-out and install the wire clamp. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure the cable. Connect wiring (see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].

11. CONNECT WIRING (ALL BLOWERS)

!

Remove wiring cover from rough-in plate or electrical compartment and set aside.

A

INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.

Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

Reinstall wiring cover.

IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.

HE0088

12. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER HOOD)

Rangemaster E6448SS — HE0088 diagram (page 11)
Fig. 17

Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside the hood (A) and the 2-prong male connector cord from rough-in plate to the 2-prong plug inside the hood (B).

Page 12 of the Rangemaster E6448SS user manual — 14. REINSTALL GREASE DRIP RAIL AND FILTERS
Page 12 · click to enlarge
Page 12

13. INSTALL LIGHT BULBS

Rangemaster E6448SS — 13. INSTALL LIGHT BULBS diagram (page 12)
Fig. 18

This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included).

Rangemaster E6448SS — 13. INSTALL LIGHT BULBS diagram (page 12)
Fig. 19
1. Install lamps by placing the bulb leads into their grooves in the socket. 2. Gently push upwards and turn clockwise until secure.

To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves. NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.

14. REINSTALL GREASE DRIP RAIL AND FILTERS

Rangemaster E6448SS — 14. REINSTALL GREASE DRIP RAIL AND FILTERS diagram (page 12)
Fig. 20

Remove protective plastic film covering filters before installing them.

Reinstall grease drip rail. The illustration beside shows how to reinsert the grease drip rail into the range hood.

It is recommended to install side filters first and finish with center one(s).

1. Insert one end of the filter into the upper channel of the hood.
2. Raise the other end toward the inside of hood and insert in the grease drip rail of the hood.
Page 13 of the Rangemaster E6448SS user manual — !
Page 13 · click to enlarge
Page 13

15. USE AND CARE

Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by the warranty.

Grease Drip Rail The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail to dry completely before reinstalling it in the hood. Blower Cleaning (Internal) Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Hood Cleaning Stainless steel cleaning:

  • Do:
  • Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
  • Always clean in the direction of original polish lines.
  • Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
  • You may also use a specialized household stainless steel cleaner.
  • Don’t:
  • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
  • Use any harsh or abrasive cleansers.
  • Allow dirt to accumulate.
  • Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface.

Avoid: When choosing a detergent

  • Any cleaners that contain bleach will attack stainless steel.
  • Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
  • Any combustible products used for cleaning such as acetone, alcohol, ether, benzol , etc., are highly explosive and should never be used close to a range.

16. OPERATION

Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

HEAT SENTRY™

This hood is equipped with a HEAT SENTRY™thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1. If blower is OFF - it turns blower ON to HIGH speed.
2. If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.

!

When the temperature level drops to normal, the blower will return to its original setting.

Page 14 of the Rangemaster E6448SS user manual — 17. WARRANTY
Page 14 · click to enlarge
Page 14

16. OPERATION (CONT’D)

Rangemaster E6448SS — 16. OPERATION (CONT’D) diagram (page 14)
Fig. 21

A) Halogen light knob B) Blower speed control knob

HC0035 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blower switch 4) Blower speed control knob

COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER

The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower operates at the previous setting of the speed control (4). Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.

17. WARRANTY

WARRANTY

ONE YEAR LIMITED WARRANTY FOR BROAN ELITE PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Broan Elite products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at one of the addresses or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. In USA - Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 In Canada - Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119

Page 15 of the Rangemaster E6448SS user manual — Broan Elite E64000 Series Exterior or In-Line blower hoods
Page 15 · click to enlarge
Page 15

18. WIRING DIAGRAMS

NEON

Rangemaster E6448SS — NEON diagram (page 15)
Fig. 22

BLK BLACK BLU BLUE BRN BROWN ORA ORANGE RED RED WHT WHITE YEL YELLOW

Broan Elite E64000 Series Exterior or In-Line blower hoods

NEON

Rangemaster E6448SS — Broan Elite E64000 Series Exterior or In-Line blower hoods diagram (page 15)
Fig. 23 · Broan Elite E64000 Series Exterior or In-Line blower…
Page 16 of the Rangemaster E6448SS user manual — * SV08353
Page 16 · click to enlarge
Page 16

19. SERVICE PARTS

Broan Elite E64000 Series Internal blower hoods

Broan Elite E64000 Series Exterior or In-Line blower hoods

HL0104

HL0103

K EY

P ART

NO. DESCRIPTION QTY. (HOOD WIDTH) 30” 36” 42” 48”

K EY

NO. PART NO. DESCRIPTION QTY. (HOOD WIDTH) 30” 36” 42” 48” 2 SV06750 BROAN ELITE LOGO 1 3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y 2 2 3 3 4 SV03435 HEAT SENTRY™ THERMOSTAT 1 5 SV08338 LIGHT SWITCH 1 6 SV03501 SPEED CONTROL 1 7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1

NO.

ADAPTER/DAMPER 3¼” X 10” (1-BLOWER HOOD) ADAPTER 4¼” x 18½” (2-BLOWER HOOD)

1 SV13296

1 2 SV06750 BROAN ELITE LOGO 1 3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y 2 2 3 3 4 SV03435 HEAT SENTRY™ THERMOSTAT 1 5 SV08338 LIGHT SWITCH 1 6 SV03501 SPEED CONTROL 1 7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1 8 SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR) 1 9 SV08344 CHARCOAL FILTER SUPPORTS (PAIR) 1

SV17797

- - - 1 12 SV08337 FILTER SPRING (SET OF 6) 1

SV17640 SV17641 SV17642 SV17643

GREASE RAIL 30” GREASE RAIL 36” GREASE RAIL 42” GREASE RAIL 48”

1. - -

- 1 - -

- - 1 -

10 SV08097 INTERNAL MOTOR (1 OR 2, DEPENDING ON HOOD MODEL) 1

13 SV17600 SV17603

2 1 - 3 2 2 - 4 14 SV08339 BLOWER ROCKER SWITCH 15 SV08093 PILOT LAMP ASS’Y 16 SV08354 ROUGH-IN PLATE 10” ROUND 17 SV13924 FEMALE CONNECTOR 18 SV13923 MALE CONNECTOR 19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3 3 4 4

BAFFLE FILTER 8.84” X 9.80” BAFFLE FILTER 11.84” X 9.80”

- - - 1 12 SV08337 FILTER SPRING (SET OF 6) 1

SV17640 SV17641 SV17642 SV17643

GREASE RAIL 30” GREASE RAIL 36” GREASE RAIL 42” GREASE RAIL 48”

1. - -

- 1 - -

- - 1 -

13 SV17600 SV17603

2 1 - 3 2 2 - 4 14 SV08339 BLOWER ROCKER SWITCH 15 SV08093 PILOT LAMP ASS’Y 19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3 3 4 4

BAFFLE FILTER 8.84” X 9.80” BAFFLE FILTER 11.84” X 9.80”

* SV08341 INSTALLATION GUIDE 1

PARTS BAG ([2] WIRE CONNECTORS, [9] SCREWS NO. 8 X 1/2”, [1] WIRE CLAMP, [8] MECHANICAL SCREWS NO. 8-32 X 1/4”, [4] SCREWS NO. 8 X 3/8”)

* SV08353

1

* SV08341 INSTALLATION GUIDE 1

PARTS BAG ([2] WIRE CONNECTORS, [9] SCREWS NO. 8 X 1/2”, [1] WIRE CLAMP, [8] MECHANICAL SCREWS NO. 8-32 X 1/4”, [4] SCREWS NO. 8 X 3/8”)

* SV08353

1

* NOT SHOWN.

* NOT SHOWN.

Page 17 of the Rangemaster E6448SS user manual — Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
Page 17 · click to enlarge
Page 17

GUIDE D’INSTALLATION

Rangemaster E6448SS — GUIDE D’INSTALLATION diagram (page 17)
Fig. 24
INSTALLATEURLAISSER CE MANUEL AU PROPRIÉTAIRE. PROPRIÉTAIRE : INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN

EN PAGES 29 et 30.

Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119

ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.broan.com/register

SV08341 rév. D

Page 19 of the Rangemaster E6448SS user manual — - SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE E64000 -
Page 19 · click to enlarge
Page 19

- SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE E64000 -

VENTILATEURS INTÉRIEURS

Rangemaster E6448SS — - SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE E64000 - diagram (page 19)
Fig. 25

MODÈLE 437 (CAPUCHON DE TOIT À HAUT RENDEMENT)

MODÈLE 407 (CONDUIT DE 7 PO ROND

MODÈLE 421 (VOLET INTÉRIEUR DE 10 PO ROND VERTICAL)

MODÈLE 413 (TRANSITION 3¼ PO X 10 PO À 8 PO)

TRANSITION (3¼ PO X 10 PO À 7 PO)

MODÈLE 410 (CONDUIT DE 10 PO ROND

CONDUIT STANDARD (3¼ PO X 10 PO)

À 10 PO ROND, 6 PO HAUT - LATÉRALE

À 10 PO ROND - HORIZ. AVANT/ARRIÈRE)

À 10 PO ROND - HORIZ. /GAUCHE)

ADAPTATEUR/VOLET 3¼ PO X 10 PO (INCLUS AVEC LA HOTTE À VENTILATEUR SIMPLE) ADAPTATEUR 4½ PO X 18½ PO

(INCLUS AVEC LA HOTTE À VENTILATEUR DOUBLE)

Page 20 of the Rangemaster E6448SS user manual — O PTIONNEL )
Page 20 · click to enlarge
Page 20

- SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE E64000 -

VENTILATEURS EN LIGNE ET EXTÉRIEURS

M ODÈLE 437 (C APUCHON DE TOIT

Rangemaster E6448SS — M ODÈLE 437 (C APUCHON DE TOIT diagram (page 20)
Fig. 26

VENTILATEUR EN LIGNE MODÈLE HLB9 (800 PCM)

OU HLB11 (1100 PCM) (INCLUANT DEUX TRANSITIONS RONDES

VENTILATEUR EXTÉRIEUR MODÈLE 335 (1200 PCM)

VENTILATEUR EXTÉRIEUR MODÈLE 331H (600 PCM)

DE 8 PO X 12 PO À 10 PO)

VENTILATEUR EN LIGNE MODÈLE HLB6 (600 PCM) (INCLUANT DEUX TRANSITIONS RONDES

DE 4½ PO X 18½ PO À 10 PO)

MODÈLE 421 (VOLET INTÉRIEUR DE 10 PO

DE 10 PO VENTILATEUR EN LIGNE MODÈLE HLB3 (280 PCM) (INCLUANT UNE TRANSITION

MODÈLE 410 (CONDUIT DE 10 PO ROND

VENTILATEURS EXTÉRIEURS OU EN LIGNE (INCLUSE AVEC LA HOTTE).

DOSSERET SÉRIE RMP (R ECOUVREMENT DE MUR

EN ACIER INOXYDABLE AVEC

SUPPORT ASSIETTES.

O PTIONNEL )

HL0098

Ask about the Rangemaster E6448SS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Rangemaster E6448SS

Be the first to ask — other owners or our team will answer.

Original document

Rangemaster E6448SS manual PDF

48 pages·4.9 MB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…