Users Guide
& Installation Instructions


These warnings are provided in the interests of safety. Ensure that you understand them all before installing or using this appliance. Your safety is of paramount importance. If you are unsure about the meaning of any of these warnings contact the Helpline.



The chimney hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. The appliance can be installed to recirculate or extract contaminated air.
BUTTON V1 - Turns the fan On and Off at
the low speed setting. This is an ideal speed when cooking for long periods as the continuous flow of air is particularly quiet.
COOKER HOOD CONTROLS The chimney hood functions are controlled by four push buttons located centrally on the front of the canopy.
BUTTON V2 - Medium speed, suitable for
most normal operating conditions. This speed gives an excellent ratio between treated air when the hood is recirculated and the level of noise.

BUTTON V3 - High speed, suitable for
removing strong odours when frying or simmering for long periods.
BUTTON L - Turns the worktop lighting On and Off.

TO OPERATE Select the required fan speed and light if required.
To obtain the best performance when cooking it is advisable to switch the chimney hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing.
RECIRCULATION In the recirculation mode contaminated air enters the chimney hood through the grease filter cassettes. The air is cleaned as it passes through the charcoal filter and is passed out through grilles in either side of the chimney stack into the kitchen.
EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ducting into the atmosphere.
When used in the ducting mode the charcoal filter is not required.
Never do flambé cooking under this chimney hood.
When using a gas hob under this chimney hood never leave the burners uncovered while the hood is in use or when the pans have been removed.
The grease filters and the charcoal filter should be cleaned and replaced as recommended or more frequently if the hood is used consistently over 4 hours per day.

Regular maintenance and cleaning will ensure good performance and reliability, while extending the working life of the hood. Special attention should be paid to the grease filter cassettes and the charcoal filter when the hood is used in the recirculation mode.
Before carrying out any mainte- nance or cleaning isolate the cooker hood from the mains supply.
THIS APPLIANCE CAN BE A POSSIBLE FIRE HAZARD IF THE GREASE FILTERS ARE NOT CLEANED AND THE CHARCOAL FILTERS REPLACED AS RECOMMENDED.
METAL GREASE FILTERS The grease filters absorb grease and dust during cooking to help keep the chimney hood clean inside, and should be cleaned every month with normal usage or more frequently if the hood is used consistently over 4 hours per day.
Replacement charcoal filters may be purchased by returning the enclosed order form, or by telephoning 01803 296155 if you wish to pay by credit card.
Remove the metal grease filter cassettes one at a time, by pressing the release catch towards the rear of the hood as illustrated opposite. When replacing the filters ensure that the handle faces forwards.

The metal grease filters can be washed in a dishwasher or by hand using a mild detergent or liquid soap.
CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours.
The charcoal filter cannot be cleaned or regenerated and must be replaced every four months, or more frequently if the hood is used consistently over 4 hours per day.

To replace the charcoal filter, first remove the metal grease filters and press against the plastic retaining clips to remove the charcoal filter as illustrated opposite.
We recommend that you wear rubber gloves when removing the charcoal filter as the filter will be saturated in grease. Put the filter into a polythene bag or container so that the grease and dirt cannot spill onto clothing of furnishing.

LIGHTING The canopy is fitted with three 20W halogen spotlamps. If one of the spotlamps fails to function check that the two pins are correctly inserted into the lamp holder.
To replace a spotlamp remove the two screws, which secure the lens retaining ring and glass lens as illustrated. Take care to ensure the lens and retaining ring are supported while removing the screws. Extract the spotlamp from the lamp holder by pulling gently.

Replacement spotlamps are specified 230V 20W.
When replacing the spotlamps, make sure that the two pins are correctly inserted in the lamp holder, and then replace the glass lens and retaining ring.
CLEANING We recommend the chimney hood is cleaned using a damp cloth wrung out in warm soapy water using a mild liquid household cleaner.
Never use excessive amounts of
water when cleaning, in particular around the control buttons.
Never use thinners or products containing alcohol, as they will damage the painted or bright metal finish.
Never use abrasive cleaning materials, or scouring pads in particular when cleaning painted or bright metal finish.

It is dangerous to alter the specifications or attempt to modify this chimney hood in any way.
PERFORMANCE SPEEDS 3 CAPACITY m3/h* 550 CAPACIITY m3/h** 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA*** 67
*IEC 61591 method for cooker hoods in evacuation mode - ** IEC 61591 method with free delivery - ***IEC 60704-2-13 method

ELECTRICAL REQUIREMENTS Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).
ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood.
This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions.
This appliance conforms to BS.800:1988 and EEC Directive No. 78 308 regarding suppression of radio and television interference.

COMPONENTS The chimney hood comprises of the following: - No 1 150x120mm ducting spigot (A) No 1 120x125mm ducting flange (B) No 1 Canopy (C) No 2 Recirculation grilles (G) No 1 Lower chimney stack (I) No 1 Recirculation ducting (P) No 2 Recirculation extension ducts (P1) No 1 Recirculation spigot (R) No 1 Upper chimney stack (S) No 1 Valve (V) optional No 2 Chimney fixing brackets (2)
Please ensure when the appliance is fitted it is easily accessible to an engineer in the event of a breakdown.

All installations must comply with local authorities requirements for the discharge of exhaust air.
Incorrect installation may affect the safety of this chimney hood.
Before installation check the wall to which the hood is to be fitted for electric cables, gas and water pipes.
This chimney hood is designed to be fixed to any vertical surface over a cooking area, and can be used in the extraction (ducted to the outside) or recirculation mode.
The installation work must be undertaken by a qualified and competent person.
Leisure Consumer Products disclaims any responsibility for damage due to incorrect installation of the chimney hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation.


CLEARANCE HEIGHTS The chimney hood is designed to be fitted over a cooking appliance. A minimum clear- ance height of 650mm (25˚ins) is required when installed above a built-in electric hob, or 700mm (27˚ins) when installed above a built-in gas hob.
When installed between adjoining wall cabi- nets, the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and worktop must be 450mm (17˚ins), and a gap of 50mm (2ins) must be maintained either side of the hob.
This chimney hood must not be in- stalled above a cooking appliance with a high level grill.
FITTING THE WALL BRACKETS 1. Draw a vertical line on the wall as illustrated, from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen. This is to ensure the correct vertical alignment of the various components during installation.


DRILLING THE HOLES 1 1. Draw a horizontal line through the vertical 970mm up the wall from the top of the cooking appliance, ensuring it is level with a spirit level.

FIXING THE CANOPY 1. Before starting to fix the canopy to the wall, it is necessary to adjust the support brackets S1 by rotating the adjustment screws clockwise about half way through their length as illustrated opposite.


DUCTING The hood is more effective when used in the extraction mode (ducted to the outside).

When used in the extraction mode ensure the ducting spigot has been correctly fitted as illustrated.
The ducting used must be Æ125 (5ins) or Æ150mm (6ins), flexible or rigid and must be manufactured from fire retardant material, produced to BS.476 or DIN.4102- B1. The choice should be made by the installer. However, we recommend flexible ducting should only be used as an accessory as rigid ducting will provide better performance while reducing noise levels.

The ducting flange B should be sleeved over the spigot A when using 125mm (5ins) ducting as the European ducting spigot is Æ120mm.
Ducting kits can be obtained from Kitchen Specialist Distriutors, Builders Merchants and DIY stores.
When the chimney hood is ducted to the outside the charcoal filter must be removed.
RECIRCULATION If you are using the hood in the recirculation mode, ensure the charcoal filter is in position.
FITTING THE RECIRCULATION DUCTING 1. Connect the duct P to the round outlet on top of the fan housing, which push fits into position, by pressing it downwards until it meets the fan casing.


by pressing it downwards until the two pieces meet.

FITTING THE TELESCOPIC CHIMNEY The chimney stack consists of two sections.



4329643 03 020412