EN
Rangemaster logo
Official user manual

Rangemaster L 540 720

9 pages·1.3 MB·Ventilation Hood·PDF·ENDEFRITNLJA
Rangemaster L 540 720
Table of Contents 18 sections Instruction Manual GB · RECOMMENDATIONS AND SUGGESTIONS · CHARACTERISTICS · Dimensions · … ShowHide
Page 1 of the Rangemaster L 540 720 user manual — Instruction Manual GB
Page 1 · click to enlarge
Page 1
Rangemaster L 540 720 — Instruction Manual GB diagram (page 1)
Fig. 1 · Instruction Manual GB
Rangemaster L 540 720 — Instruction Manual GB diagram (page 1)
Fig. 2 · Instruction Manual GB
Rangemaster L 540 720 — Instruction Manual GB diagram (page 1)
Fig. 3 · Instruction Manual GB

Instruction Manual GB

Page 2 of the Rangemaster L 540 720 user manual — Instruction Manual GB
Page 2 · click to enlarge
Page 2
Page 2 of the Rangemaster L 540 720 user manual — Instruction Manual GB
Page 3 of the Rangemaster L 540 720 user manual — RECOMMENDATIONS AND SUGGESTIONS
Page 3 · click to enlarge
Page 3

RECOMMENDATIONS AND SUGGESTIONS

  • INSTALLATION
  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • The minimum safety distance between the cooker top and the extractor hood is 650 mm.
  • Check that the mains voltage corresponds to that indicated on the rating plate fi xed to the inside of the hood.
  • For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust fl ue through a pipe of
  • minimum diameter 120 mm. The route of the fl ue must be as short as possible.
  • Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fi replaces, etc.).
  • If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a suffi cient degree of aeration must be guaranteed in the room in order to prevent the backfl ow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
Rangemaster L 540 720 — RECOMMENDATIONS AND SUGGESTIONS diagram (page 3)
Fig. 4
  • USE
  • The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
  • Never use the hood for purposes other than for which it has ben designed.
  • Never leave high naked fl ames under the hood when it is in operation.
  • Adjust the fl ame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
  • Deep fat fryers must be continuously monitored during use: overheated oil can burst into fl ames.
  • The hood should not be used by children or persons not instructed in its correct use.
Rangemaster L 540 720 — RECOMMENDATIONS AND SUGGESTIONS diagram (page 3)
Fig. 5
  • MAINTENANCE
  • Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
  • Clean and/or replace the Filters after the specifi ed time period.
  • Clean the hood using a damp cloth and a neutral liquid detergent.
Page 4 of the Rangemaster L 540 720 user manual — Dimensions
Page 4 · click to enlarge
Page 4

CHARACTERISTICS

Dimensions

Rangemaster L 540 720 — Dimensions diagram (page 4)
Fig. 6 · Dimensions

Hood Type 54 72 L 540 720 L1 512 692

Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 9 1 Reducer Flange ø 150-120 mm Ref. Q.ty Installation Components 12c 2 Screws 2,9 x 6,5

Page 5 of the Rangemaster L 540 720 user manual — Drilling the Support surface and Fitting the Hood
Page 5 · click to enlarge
Page 5

INSTALLATION

Drilling the Support surface and Fitting the Hood

  • The Hood can be fi tted directly to the underside of the Wall units (min. 650 mm above the cooker top) with snap-on side supports, which are set up for a support panel thickness of between 15 mm and 30 mm.
  • Cut a fi tted opening in the bottom surface of the wall unit, as shown.
  • Remove the metal grease fi lters (see par. on Maintenance).
  • Disconnect the fi lter support by turning the internal handles provided.
  • Insert the hood until the side supports snap into place.
  • Lock in position by tightening the screws Vf from underneath the hood.
Rangemaster L 540 720 — Drilling the Support surface and Fitting the Hood diagram (page 5)
Fig. 7 · Drilling the Support surface and Fitting the Hood
Rangemaster L 540 720 — Drilling the Support surface and Fitting the Hood diagram (page 5)
Fig. 8 · Drilling the Support surface and Fitting the Hood
Rangemaster L 540 720 — Drilling the Support surface and Fitting the Hood diagram (page 5)
Fig. 9 · Drilling the Support surface and Fitting the Hood
Page 6 of the Rangemaster L 540 720 user manual — RECIRCULATION VERSION AIR OUTLET
Page 6 · click to enlarge
Page 6
  • Replace the fi lter support
  • Screw the fi lter support using the 2 screws 12c (2,9 x 6 ,5) provided.
  • Replace the grease fi lters make sure that the handle is visible on the outside.
Rangemaster L 540 720 — DUCTED VERSION AIR EXHAUST SYSTEM diagram (page 6)
Fig. 10

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a fl exible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.

  • To install a ø 120 mm air exhaust connection, insert the reducer fl ange 9 on the hood body outlet.
  • Fix the pipe in position using suffi cient pipe clamps (not supplied).
  • Remove any activated charcoal fi lters.
Rangemaster L 540 720 — DUCTED VERSION AIR EXHAUST SYSTEM diagram (page 6)
Fig. 11

RECIRCULATION VERSION AIR OUTLET

  • Drill a hole ø 120 or 150 mm in the shelf above the hood and connect the hood canopy outlet to the top part of the wall unit by means of a rigid or fl exible pipe of the same diameter, the choice of which is at the discretion of the installer.
  • To install a ø 120 mm air exhaust connection, insert the reducer fl ange 9 on the hood body outlet.
  • Fix the pipe in position using suffi cient pipe clamps (not supplied).
  • Ensure that the activated charcoal fi lters have been inserted.
Rangemaster L 540 720 — RECIRCULATION VERSION AIR OUTLET diagram (page 6)
Fig. 12

ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

Page 7 of the Rangemaster L 540 720 user manual — USE
Page 7 · click to enlarge
Page 7

USE

Control Panel The hood can be switched on pushing directly onto the requested speed without fi rstly having to select 0/1 button.

KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off. T1 0/1 Motor on First speed. When pressed for about 2 seconds the motor is switched off. T2 Speed on Second speed. T3 Speed on Third speed. T4 Speed Fixed Max. speed Flashing Intensive speed. Suitable for the strongest cooking vapours and odours.

The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons. S1 Led Fixed Indicates that the Metal grease fi lters saturation alarm

has been triggered, and the fi lters need to be washed. The alarm is triggered after 100 working hours. (Reset; check the Maintenance-paragraph) Flashing indicates that the activated charcoal odour fi lter satu-

ration alarm has been triggered, and the fi lter has to be replaced; the metal grease fi lters must also be washed. The activated charcoal odour fi lter is triggered after 200 working hours. (Activation and Reset; check the Maintenance-paragraph)

· ·

Page 8 of the Rangemaster L 540 720 user manual — CLEANING METAL GREASE FILTERS
Page 8 · click to enlarge
Page 8

REMOTE CONTROL (OPTIONAL)

  • The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type.
  • Do not place the remote control near to heat sources.
  • Used batteries must be disposed of in the proper manner.

MAINTENANCE

Grease fi lters

CLEANING METAL GREASE FILTERS

  • Alarm signal reset
  • Switch of the lights and extractor motor.
  • Press button T3 for at least 3 seconds, until the leds start to fl ash.
  • Cleaning the fi lters
  • The fi lters are washable and must be cleaned when led S1 fl ashes or at least every 2 months of operation, or more frequently for particularly heavy usage.
  • Remove the fi lters one at a time, supporting them with one hand and turning the safety knobs (pull and turn).
  • Wash the fi lters, taking care not to bend them. Allow them to dry before refi tting.
  • Replace them and fi x them using the safety knobs provided (pull and turn).
Page 9 of the Rangemaster L 540 720 user manual — LIGHT REPLACEMENT
Page 9 · click to enlarge
Page 9

Activated charcoal fi lter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

  • The fi lter is not washable and cannot be regenerated. It must be replaced when led S1 fl ashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on. Alarm signal reset
  • Switch off the lights and extractor motor.
  • Press button T3 for at least 3 seconds, until the leds start to fl ash. Replacing the Filter
  • Remove the grease fi lters.
  • Remove the saturated activated charcoal fi lters as shown (A).
  • Fit new fi lters (B).
  • Replace the grease fi lters. Alarm signal activation
  • In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date.
  • Turn the Lights and the suction Motor off.
  • Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
  • Restore the connection by pressing and holding T1 .
  • Release the button. All fi ve LEDs are turned on
  • Within 3 seconds press T1 until LEDs T1 and T4 fl ash in confi rmation: LED fl ashes twice - Activated charcoal fi lter saturation alarm ENABLED LED fl ashes once - Activated charcoal fi lter saturation alarm DISABLED

Lighting

LIGHT REPLACEMENT

  • 50 W halogen light.
  • Remove the 2 screws fi xing the light cover.
  • Remove the lamp by gripping the protruding part and turning to the left.
  • Replace with a new lamp with the same characteristics, making sure that you insert the two pins properly into their housings.
  • Replace the cover and fi x it in position using the two screws removed as above

Ask about the Rangemaster L 540 720

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Rangemaster L 540 720

Be the first to ask — other owners or our team will answer.

Original document

Rangemaster L 540 720 manual PDF

9 pages·1.3 MB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…