PSC Scanning, Inc.
959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Telefax: (541) 345-7140
All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. Owners of PSC Inc.’s products are hereby granted non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser’s own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained on this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting PSC Customer Administration. Elec- tronic versions will either be downloadable from the PSC web site (www.pscnet.com) or provided on appropriate media. If you visit our web site and would like to make comments or suggestions about this or other PSC publications, please let us know via the “Contact PSC” page.
Reasonable measures have been taken to ensure that the information included in this manual is complete and accurate. However, PSC reserves the right to change any specification at any time without prior notice.
PSC and the PSC logo are registered trademarks of PSC Inc. All other trademarks and trade names referred to herein are property of their respective owners.



After unpacking your new scanner, check the contents of the ship- ping carton to ensure all the items you ordered are included:
If your package contains wrong or missing components, contact your place of purchase. If there are damaged components, immediately file a claim with the carrier. You may want to save your packing material in case you need to ship the scanner at some later time.
Manuals for the PowerScan scanner are available on our website. See the back cover for our web address.

Refer to Figure 1 and follow these steps to install the scanner:
Consult your host terminal manual to determine if power must be turned off before connecting peripheral devices such as the scanner.
Do not attempt to pull the End Cap off, as this may damage the scanner.
The scanner requires either a Listed Class 2 or Listed LPS power source which supplies power directly to the scanner.



Figure 2 illustrates some tips to help get the best scanning results:


There are currently four different model types for this scanner. Depending upon the model type of your scanner, you’ll need to hold the unit at a given distance from the bar code to achieve optimum scanning results. The following diagrams provide range of field infor- mation for each of the models when scanning grade A, Code 39 bar codes: Standard Range (SR), High Density (HD), Long Range (LR) and Extra Long Range (XLR).
In the context of the illustration below, a "mil" repre- sents the minimum bar code element width. Mea- surements are based on SR models set with the standard 28° scan width (as opposed to the Half Angle setting of 14°). Reference the PowerScan Pro- gramming Manual (P/N R44-1840) for more informa- tion about the Half Angle feature.
Specifications are subject to change without notice.
Depth of Field
Paper Labels (SR decoded model, Code 39)
7.5 mil
1 2 3 4 5
20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170

In the context of the illustration below, a "mil" repre- sents the minimum bar code element width. Mea- surements are based on HD models set with the standard 28° scan width (as opposed to the Half Angle setting of 14°). Reference the PowerScan Pro- gramming Manual (P/N R44-1840) for more informa- tion about the Half Angle feature.
Specifications are subject to change without notice.
FRONT OF SCANNER
7.5 mil
1 2 3 4 5 6 7 8
0 CENTIMETERS 5


In the context of the illustration below, a "mil" repre- sents the minimum bar code element width. Mea- surements are based on LR models set with the a 14° scan width (as opposed to the alternate Full Angle setting of 28°). Reference the PowerScan Pro- gramming Manual (P/N R44-1840) for more informa- tion about the Half Angle feature.

20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
170 180 190 200 210 220 230 240 250 260 270 280
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
670 650 630 610 590 570 550 530 510 490 470 450 430 410 390 370 350 330 310 290 270 250 230 210 190 170 150 130 110 90 70 50 30 10


In the context of the illustration below, a "mil" repre- sents the minimum bar code element width. Mea- surements are based on XLR models set with a 10° scan angle width.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
450 400 350 300 250 200 150 100 50
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
1100 1050 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50

The active (enabled) bar code symbologies in the factory defaults are:
Your scanner should be pre-programmed with these standard factory default settings, unless...
...it was shipped to you programmed with unique, customer con-
figuration settings.
...you or another user have made changes to scanner program-
ming.
Decoded scanners can be programmed to decode extremely poor quality bar codes by activating advanced Quadralogic™ Decoding. To select this feature, see the PowerScan™ Scanner Programming Guide (P/N R44-1840) available from your dealer, or you can down- load the manual from our website.
Scanner programming can also be performed using your PC and the Configurator Express™ On-Screen Programming tool also available from your dealer.

The bar code below (Figure 7) is provided to test your scanner’s abil- ity to read a typical Code 39 label.
T e s t

Complies with 21CFR 1040 and part 15 of FCC Rules. Applicable patents are listed on label inside unit.
1mw - 650-685nm CLASS 2 LASER PRODUCT Based on 100 sec., EN60825-1/A11:1996
COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:

Figure 8 above shows label placement ONLY. For actual regulatory, patent and other applicable infor- mation, view the labels on the product itself, or call your nearest sales or service representative.

The PowerScan bar code scanner is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J for Class II laser products. Class II products are not considered to be hazardous. The scanner contains a Visible Laser Diode (VLD) at a wavelength of 650- 670 nanometers and is designed so that there can be no human access to harmful levels of laser light during normal operation, user mainte- nance, or during prescribed service operations.
If the scan pattern is a single dot when depressing the trigger, discontinue operation and return the unit to the factory. Exception: When using Marker Beam Mode a single aiming dot is projected momentarily.
Do not attempt to open or otherwise service any components in the optics cavity. Opening or servic- ing any part of the optics cavity by unauthorized personnel may violate laser safety regulations.
Radio Frequency Interference
This device complies with Part 15 of the FCC Rules. Operation is sub- ject to the following two conditions:
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe B respecte toutes les exigences du Reglement sur le material broilleur du Canada.

You can isolate problems with your scanning system by performing these checks (refer to Figure 9):
7. Verify that the bar codes you are scanning are of satisfactory quality. Bar code label verifiers are available from your dealer if you need precise reporting of bar code details. Bar codes that are damaged (wrinkled, smudged, or torn) may cause the scanner to read poorly or not at all. If bar code quality seems to be the problem, check to see if the scanner will read a known good bar code (see Figure 7). You may also want to modify the programmable setting for advanced Quadralogic™ decoding (see the section in this manual titled, Enhanced Scanning for Hard-to-Read Bar Codes).


9 9 5 3 1 7 5 7 9 0


PSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards:
Standards: EN55022-B EN60825 EN50082-1 EN60950
Equipment
Type: Bar Code Scanning Equipment
Product: PowerScan™ Bar Code Scanner PowerScan™ LR Bar Code Scanner PowerScan™ XLR Bar Code Scanner


Charles W. Vanlue Director, Corporate Quality PSC, Inc. 959 Terry Street Eugene, OR 97402 U.S.A.
Nigel Davis Vice President Europe, Middle East & Africa PSC Bar Code Ltd. Axis 3, Rhodes Way Watford, England WD24YW UK

Asia Pacific PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291
Italy PSC S.r.l. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/685496
Australia PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688
Japan PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656
France PSC Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.44
Latin America PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Fax: (305) 539-0206
Germany PSC GmbH Darmstadt, Germany Telephone: + 49 (0) 61 51/93 58-0 Fax: + 49 (0) 61 51/93 58 58
United Kingdom PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Fax: 44 (0) 1923 809 505
Corporate Headquarters 675 Basket Road Webster, NY 14580-9787 Telephone: (716) 265-1600 Fax: (716) 265-6400
PSC Scanning, Inc. 959 Terry Street Eugene, OR 97402-9150 Telephone: (541) 683-5700 Fax: (541) 686-1702
PRINTED WITH SOY INK
Printed on recycled paper
© 2000 PSC INC. R44-2094 (Rev. B) Printed in USA (11/00)
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.