The serial number is on a sign behind the access panel. Write the serial number in the space above.
If you have questions, or if there are missing parts, we will guar- antee complete satisfaction through direct assistance from our factory.
TO AVOID DELAYS, PLEASE CALL DIRECT TO OUR TOLL- FREE CUSTOMER HOT LINE. The technicians on our customer hot line will provide immediate assistance, free of charge.
Read all precautions and instruc- tions in this manual before using this equipment. Save this manual for future reference.



physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy.
29. DANGER—To reduce the risk of drowning: Prolonged immersion in the hydrotherapy spa may cause hyperthermia. The causes, symp- toms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F. The symp- toms of hyperthermia include an increase in the internal temperature of the body, dizzi- ness, lethargy, drowsiness and fainting. The effects of hyperthermia include failure to per- ceive heat; failure to recognize the need to exit the spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub and unconsciousness resulting in danger of drowning. WARNING: The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia.


Congratulations for selecting the new PROFORM®
For your benefit, read this manual carefully before using the hydrotherapy spa. If you have questions after reading the manual, please call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please mention the product model number and serial number when calling. The model number is PFSB73930. The serial number can be found on a decal on the access panel inside the spa (see the front cover of this manual).
MAGNA hydrotherapy spa. The innovative MAGNA spa allows you to enjoy all the benefits of hydrothera- py in the comfort and privacy of your home.
Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life. The warm environment stimulates blood flow, which is essential in the healing process, and the powerful massage action further eases tension and stress throughout the body. The PROFORM MAGNA hydrotherapy spa gives you the specialized treatment you need to feel your best.
Before reading further, please familiarize yourself with the parts that are labeled in the drawing below.

There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.
If you set up the hydrotherapy spa inside:
If you set up the hydrotherapy spa outside:
10.Make sure to note any other considerations, such as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the spa.

Before beginning assembly, carefully read the following information and instructions:
ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included):
A wire connector is provided on the electronics pack of the spa to connect a minimum No. 6 AWG (13.3 mm2) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa.
Remove the four #10 x 2” Machine Screws (46) that secure the indicated Access Panel (25) to the spa. Carefully remove the Access Panel and set it aside. Be careful not to damage the spa shell.
Locate the four gate valves inside the access open- ing (there are two gate valves per pump). Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves, as shown in the inset drawing.
Make sure that the six collars are tightened (there are two collars per pump and two on the heater).
Refer to step 1. Re-attach the Access Panel (25) to the spa.

4. The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed electrician. A wiring diagram is found on the inside of the electronics package for reference. Under no circumstances should the spa be wired by someone other than a qualified electrician. Before you have the spa wired, make sure it is in the desired position, and that it can be easily serviced, if needed.
Remove the two warning decals (see page 5) from the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to easily service it. Once the spa is filled, it will have to be drained before it can be moved.
Insert a garden hose into the filter housing, and begin filling the spa. Do not use soft water. The spa may be filled with cold water; however, if warm or hot water is used, the spa will be ready for use sooner. Fill the spa until the water is at the level of the molded fill line. Do not overfill the spa.
Refer to the inset drawing. Set the Filter (5), Filter Plug (16), Diverter (21), and Basket (22) into the fil- ter housing. Next, screw the Filter Cover (3) into the filter housing until it is fully seated.
6. Pull down one of the straps on the Spa Cover (11) and hold the Buckle (26) against one of the panels on the spa. (Note: To position the Buckle correctly, have a second person hold the strap on the opposite side of the Spa Cover snug.) The Spa Cover must be snug. Do not place the Buckle over the grooves between the premium cedar panels. Refer to the inset drawing. Remove the latch from the Buckle (26). Attach the Buckle to the panel with two #4 x 3/4” Screws (27).
Attach the other three Buckles (26) to the panels in the same way.
Remove the Spa Cover (11) from the spa.

The hydrotherapy spa is designed to seat seven adults. The spa holds approximately 375 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.
A countdown from “005” to “000” will appear in the display of the console.
Once the countdown has reached “000,” “Pr” will be displayed. “Pr” indicates that the controller is in the two-pump priming mode. This mode will last for four to five minutes.
The hydrotherapy spa is designed to operate with a 240 volt AC power source. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 45 amps. No other appliance should be on the same circuit. Test the GFCI before connecting the power cord to the spa. Connection of the spa to the 240 volt power source must be performed by a qualified, licensed electrician and must comply with all local, state, and federal electrical codes. Please refer to the instructions on the inside of the controller for informa- tion about connecting the spa to a 240 volt power source.
If water is not flowing from the jets after two min- utes, turn the power off. Important: Do not allow the pumps to run without priming for more than two minutes. Under no circumstances allow a pump to run without priming beyond the end of the four to five minute priming mode. Doing so may cause damage to the pump and cause the spa to go into an overheat condition.
Once the spa is filled with water, the power can be turned on. Note: If this is the first time the spa has been turned on, or if the pumps have been drained, the pumps must be primed before the spa can be used.
Repeat the process of venting the air from the pumps and the controller and priming the pumps until water flows from the jets.
To prime the pumps, follow the steps below.
Once the pumps are primed, push pump button 1 and pump button 2 to turn the pumps off.
Loosen this · Collar

Once you have tested the GFCI, verify that water is flowing from the jets. Set the air controls to the lowest setting (see USING THE CONTROLS on page 13). Cover the hydrotherapy spa with the spa cover. The spa cover must be tight (see SECURING THE SPA COVER ON THE SPA on this page). The water will heat at about 6°F per hour with the cover on. If you are using the spa indoors, and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.
The controller will automatically heat the water and all of the features of the console will be avail- able. To use the console, see USING THE CON- TROLS on page 13
The temperature and the water flow can be set or changed with the controls on the console (see USING THE CONTROLS on page 13).
TESTING AND TREATING THE WATER
To secure the spa cover, snap the latches on the spa cover into the buckles on the panels. To lock the buckles, insert the key and turn it clockwise 1/4 turn. To unlock the buckles, insert the key and turn it counterclockwise 1/4 turn. Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children.
The first time you use the spa, you should test and treat the water. You must also treat the water each time you refill the spa. A test strip and a chemical pack are available at your local pool and spa store. Follow the directions carefully on the chemical pack to test and treat the water. Always keep the chemicals away from children and pets.
See WATER CHEMISTRY on page 16 for information concerning proper water maintenance.
You should always test the GFCI before using the hydrotherapy spa. First, turn on the spa. Press the jet button on the console (see USING THE CONTROLS on page 12). Once the spa is running, press the GFCI “test” button. The spa should shut off. Press the “reset” button. The spa should resume normal opera- tion. If the spa continues to run after the “test” button is pressed, the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.
Latch · Key · Buckle

P
K K K K
J
M M
Q
N
K
K
D
L B
F
G
H
K
E I
O
P
K
A
A. The filter can be removed for cleaning or replace-
H. The console controls the jets, turns the underwater
ment (see CHECKING AND CLEANING THE FIL- TER on page 15).
light on and off, and adjusts the water temperature (see USING THE CONTROLS on page 13).
B. The underwater light can be used for night opera-
I. The four air controls regulate the air flow to the
tion (see USING THE CONTROLS on page 13). The spa includes both red and blue covers for the light.
whirlpool, hydrotherapy, and volcano jets.
J. The two neck jets can be adjusted to spray sooth-
ing water on your neck.
C. The ten air injectors create air bubbles that
enhance the hydrotherapy experience.
K. The twenty rotary jets provide a spinning mas-
sage.
D. The volcano jet provides a soothing foot massage.
L. The nine dual rotary jets provide a pulsating mas-
E. The whirlpool jet diverts the water flow four differ-
sage action. Rotate the outer ring counterclockwise to turn the jets on. Rotate the outer ring clockwise to turn the jets off.
ent ways. By turning the outer ring, you can divert the water flow between the volcano jet (D), the other jets on the spa, and the whirlpool jet (E), which creates a whirlpool action. Note: The outer ring may be hard to turn while the pump is turned on high.
M. The three variable-flow jets are fully adjustable.
Turn the outer rings to regulate the flow.
N. The power massage jet provides a soothing mas-
F. The four suction fittings provide water to the
sage to your lower back. Turn the outer ring to reg- ulate the flow.
pumps. The suction covers should always be in place over the fittings. Never operate the spa with- out the suction covers in place.
O. The skimmer cleans the surface of the water.
G. An optional ozone generator can be purchased and
P. The waterfall provides a soothing sound and mas-
installed to utilize the ozone jet. Ozone helps sani- tize the spa with minimal chemical treatment.
sage.
Q. The waterfall valve turns the waterfall off and on.

1, 2, and 3
Light Button Pump Button 1
current only when pump 1 has been operating for two minutes. “STD” displays momentarily when standard mode is selected.
Air Control 1 determines the amount of air flowing through the hydrotherapy jets labeled 1 in the drawing above. If the control is turned counterclockwise, the amount of air will increase; if the control is turned clockwise, the amount of air will decrease. Air controls 2, 3, and 4 function in the same manner.
Pump Button 1 controls the spa jets labeled 3 and 4 in the drawing at the left. If the button is pressed once, the jets will run, providing gentle hydrotherapy. If the button is pressed again, the jets will shut off.
Pump Button 2 controls the spa jets labeled 1 and 2 in the drawing at the left. If the button is pressed once, the jets will run, providing soothing hydrothera- py. If the button is pressed again, the jets will shut off. The spa also features an automatic mode that heats and filters the water when the spa is left unattended. When the power to the spa is first turned on, or if the water temperature is below the set temperature, the water will be heated as required. Note: To keep the filter and heat cycles from running, the power to the spa must be turned off.
Air Controls 2, 3, and 4 determine the amount of air flowing through the hydrotherapy jets labeled 2, 3, and 4 in the drawing above.
The Mode Button switches the console between Standard, Economy, and Sleep modes.

The Light Button turns the underwater light on and off.
20°F cooler than the set temperature. When this hap- pens, the heater will automatically activate to warm the water. The word “ICE” will appear in the display if the temperature drops below 40°F. If this happens, the pump will automatically circulate the water and warm the plumbing to keep the water from freezing.
The Temperature Buttons control the temperature set- ting of the water. The temperature setting can be from 80°F to 104°F. The water heats at about 6°F per hour with the cover on. Use a medical or other accurate thermometer to check the temperature of the water. Note: The word “COOL” will appear in the console display if the temperature of the water is more than
The Blower Button turns the ten air injectors, labeled 6 in the small drawing on page 13, on and off.

The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa.
The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.
The filter should be checked periodically for build-up of dirt and oil. If the filter needs to be cleaned, follow the steps below:
1. Turn off the power. 2. Unscrew the filter cover. 4. Lift the the filter out of the filter housing. 5. Check the filter for dirt and debris. If the filter needs to be cleaned, rinse the fil- ter with a hose. If the filter is still dirty, soak it in cleaning solution from a pool and spa supply store. 6. Inspect the filter for damage. Replace the filter if it is dam- aged. 7. Insert the cleaned or new filter into the fil- ter housing. 8. Re-attach the filter cover.
The surround is maintenance free. The surround should be cleaned with a mild soap solution; do not use solvents or waxes.
The spa shell should be cleaned with a mild soap solution; do not use solvents or waxes. The spa should always be clean and dry before being moved or stored.

To maintain the proper pH level, test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supply store. The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional infor- mation about testing and adjusting the pH.
Maintaining the pH level of the water is very important to the operation of the spa. To maintain the proper pH level and to sanitize the spa, you can purchase a chemical starter kit from your local pool and spa sup- ply store.
CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guide- lines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Do not exceed the recommended amounts of chemicals—follow the directions on the label. 4. Keep all chemicals out of the reach of children and pets. 5. Keep all containers closed tightly when not in use. 6. Never add water to the chemicals—always add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place.
The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, and water conditions. Proper water maintenance is a com- plex process. Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.
The spa will filter the water every 12 hours. The dura- tion of the cycle can be adjusted to last 2, 4, 6, or 8 hours or run indefinitely. Press the temperature up or temperature down button on the console. When the display begins to flash, press pump button 1. The dis- play will read “F2.” To change the time, press the temp up button until the desired time is reached. Press pump button 2 to confirm the selection.
The pH factor is a measure of the relative acidity or alkalinity in the water, and is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa.
Pump 2 purges for five minutes and the blower purges for 30 seconds at the beginning of each filter cycle. Pump 1 will run on low during filtration and the ozone generator will be enabled.
Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.
As spa usage increases, the duration of the filter cycle may need to be increased.

Turn off the spa power. To remove the indicated Access Panel (25), remove the four #10 x 2” Machine Screws (46) that secure the Access Panel to the spa. Carefully remove the Access Panel and set it aside.
To replace the Access Panel, hold the Access Panel in place and secure it with the four #10 x 2” Machine Screws (46). Be careful not to overtighten the Screws.
Drain Hose Valve Knob
The hydrotherapy spa should be drained at least four times per year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made.
The hydrotherapy spa should always be covered when it is empty. Direct sunlight can cause exten- sive damage. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty.
To drain the hydrotherapy spa, follow the steps below:
Cap

REPLACING THE LED LIGHT
After the hydrotherapy spa is drained, the jet pumps should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez- ing temperatures.
If the underwater light burns out, you will need to remove the access panel to replace it (see ATTACHING AND REMOVING THE ACCESS PANEL on page 17). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell.
Turn off the power to the spa. To drain the jet pumps, remove the access panel from the spa (see ATTACHING AND REMOVING THE ACCESS PANEL on page 17). Locate the jet pumps inside the spa. Loosen the indicated collar on each of the pumps.
To replace the LED light, pull the old LED light out of the housing and insert a new LED light. Re-attach the light housing to the spa shell. Re-attach the access panel to the spa.
The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winter- ize the spa.
1. Make sure the power to the spa is turned off. 2. Drain the spa (see DRAINING THE HYDROTHER- APY SPA on page 17). 3. Remove all remaining water from the spa shell. Dry the spa shell with towels. 4. Set the air controls to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each jet, starting with the highest jet and fin- ishing with the lowest jet. 5. Set the air controls to the highest setting and repeat step 3. 6. Drain the pumps (see DRAINING THE PUMPS on this page). Once the water is drained from the pumps, place the vacuum nozzle over the drainage hole in the pumps and vacuum any additional water from the pumps. Note: For additional pro- tection, remove the pumps/motors from the spa and store them in a climate-controlled room. 7. Clean the spa shell (see page 15). 8. Clean the filter (see page 15). 9. Shut the power off at the breaker. Label the breaker in such a way that the breaker will not be turned on accidentally. 10. Re-attach the access panel and the spa cover.

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time.
6. SYMPTOM: THE WATER DOES NOT HEAT
a. Check to see if the GFCI breaker is tripped or
a. Make sure that the hydrotherapy spa is fully
was not turned on. Reset the GFCI breaker.
covered with the spa cover. The spa cover must be tight for the water to heat. Set the air control to low. The water will heat at a rate of 6°F per hour. If you are using the spa indoors and the room temperature is main- tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.
a. Reset the circuit breaker or the GFCI. If the cir-
cuit breaker or the GFCI trips again, contact a qualified electrician for service.
b. If you are using the hydrotherapy spa outdoors,
it may take longer for the water to heat. See the chart below for the approximate heating time.
a. The filter may be dirty or damaged. Remove
the filter from the filter housing and clean or replace the filter (see page 15).
Air Temperature Heating Time 70°F + 6 to 8 hours 50°F to 70°F 9 to 11 hours 30°F to 50°F 12 to 14 hours
b. The pump may have a foreign object stuck in
the impeller. Contact our customer service department.
b. If the water still has not heated after four days,
c. The pump may have a loose wire connection.
contact our customer service department.
Contact our customer service department.
a. Check to see if the filter are in place. Clean the
a. The pump may be jammed. Contact our cus-
filter if they are dirty.
tomer service department. If your spa is no longer under warranty, contact a local spa and pool service provider.
b. Check the chemical balance of the water. If the
pH is incorrect, the sanitizing agents will not function properly. See the section on maintain- ing the proper pH balance on page 16.
a. There may be debris in the pump. Contact our
customer service department.
a. This usually occurs only when the water level is
b. The pump may have a bad bearing. Contact
low. Add water until it is 2” to 4” above the skimmer basket.
our customer service department.
b. The filter cover may not be tight. Make sure the
filter cover is tight.

a. A clamp or seal inside the pump compartment
may be loose. Check inside the pump compart- ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside of the spa jet unit, tighten the clamp or replace the damaged seal.
a. If the console displays one of the messages
listed above, or if the console does not function correctly, please call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays).
b. Some water loss due to evaporation is normal.
If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, the spa shell may have a leak. Contact your local pool and spa service provider for repairs.
a. To turn off the main jets, press pump button 1
once or twice. Note: If the actual temperature of the water in the spa is below the set temper- ature, or if the spa is running a filter cycle, the heater pump/motor will not shut off.


Key No. Qty. Description Key No. Qty. Description
1 1 Console With Overlay 2 2 3-wire Power Cord 3 1 Filter Cover 4 8 Rubber Washer 5 1 Filter 6 2 Rubber Isolator 7 1 Blue Light Cover 8 1 Red Light Cover 9 4 #10 x 1 1/2” Sheet Metal Screw 10 1 2-speed Pump* 11 1 Spa Cover 12 9 Dual Rotary Jet Face 13 4 Jet Pump/Motor O-ring 14 1 Controller* 15 3 Medium Jet Housing 16 1 Cartridge Plug 17 4 Suction Cover Assembly 18 4 Air Control Knob 19 1 1-speed Pump* 20 1 4-wire Power Cord 21 1 Diverter 22 1 Basket 23 8 1/4” Lock Washer 24 1 Filter Housing Door 25 1 Access Panel 26 4 Buckle 27 8 #4 x 3/4” Screw 28 10 1/4” x 1 1/2” Screw 29 1 Overlay 30 1 Whirlpool Jet 31 14 1/4” Washer 32 1 Face Plate Assembly 33 3 Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet
36 3 Nozzle Housing 37 21 Small Rotator 38 1 Large Rotary Jet 39 1 Face Ring 40 1 Small Nozzle 41 22 Jet Ring 42 1 Nozzle Bushing 43 21 Pivot Ring 44 3 Medium Nozzle 45 2 Drain Plug 46 32 #10 x 2” Machine Screw 47 2 Pillow 48 2 Drain Plug O-ring 49 4 Corner Panel 50 2 Neck Jet 51 1 Filter Housing* 52 9 Dual Rotary Jet 53 2 Heater Gasket 54 2 Waterfall Valve 55 10 Air Injector Assembly 56 1 Blower # 2 Ground Wire # 2 Key # 1 User’s Manual # 1 Large Warning Sign # 1 Warning Sign # 1 LED Light
* Indicates a part that is serviceable only by service technicians.
# Indicates a non-illustrated part.
Specifications are subject to change without notice.



To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling:
ICON Health & Fitness, Inc. (ICON), warrants this product to be free from defects in workmanship and mate- rial, under normal use and service conditions, for a period of ninety (90) days from the date of purchase. ICON extends a limited five (5) year warranty on the spa shell structure. ICON extends a limited two (2) year war- ranty on the pump, motor, and electronics package. This warranty extends only to the original purchaser. ICON's obligation under this warranty is limited to replacing or repairing, at ICON's option, the product through one of its authorized service centers. All repairs for which warranty claims are made must be pre-authorized by ICON. This warranty does not extend to any product or damage to a product caused by or attributable to freight damage, abuse, misuse, improper or abnormal usage, or repairs not provided by ICON authorized ser- vice personnel; to products used for commercial or rental purposes; or to products used as store display mod- els. Specifically excluded are damages caused by or attributable to the following incidents: any damage to the premium cedar surround or frame attributable to improper handling or freight damage; damage resulting from improper winterization; damage to the spa shell resulting from improper chemical treatment, damage to the spa shell resulting from exposure to extreme temperatures, or damage to the spa shell resulting from expo- sure to direct sunlight and ultraviolet rays while the spa is empty; damage to the pump, motor, plumbing, and components due to improper maintenance, chemical treatment, or exposure; or damage resulting from failure to properly follow user’s manual installation, operating, or maintenance instructions. Also excluded are con- sumable components, including but not restricted to filter cartridges. No other warranty beyond that specifi- cally set forth above is authorized by ICON.
ICON is not responsible or liable for indirect, special or consequential damages arising out of or in connection with the use or performance of the product or damages with respect to any economic loss, loss of or damage to property including water damage, loss of revenues or profits, loss of enjoyment or use, costs of removal, installation or other consequential damages of whatsoever nature. Some states do not allow the exclusion or limitation of incidental or consequential damages. Accordingly, the above limitation may not apply to you.
The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of mer- chantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein. Some states do not allow limitations on how long an implied warranty lasts. Accordingly, the above limitation may not apply to you.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813
Part No. 195331 R0303A Printed in USA © 2003 ICON Health & Fitness, Inc.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.