As a manufacturer, we are com- mitted to providing complete customer satisfaction. If you have questions, or find that there are missing or damaged parts, we will guarantee complete satis- faction through direct assistance from our factory.

TO AVOID UNNECESSARY DELAYS, PLEASE CALL DIRECT TO OUR TOLL-FREE CUSTOMER HOT LINE. The trained techni- cians on our customer hot line will provide immediate assis- tance, free of charge to you.

CUSTOMER HOT LINE: 1-800-999-3756 Mon.ÐFri., 6 a.m.Ð6 p.m. MST

CAUTION

USER'S MANUAL

Read all precautions and instruc- tions in this manual before using this equipment. Save this manual for future reference.

¨ · Serial Number Decal

Page 3 of the ProForm PFHS60070 user manual — READ AND FOLLOW ALL INSTRUCTIONS
Page 3 · click to enlarge
Page 3

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

1. It is the responsibility of the owner to ensure that all users of the RESTORATION 600 are adequately informed of all precautions.
13. Keep all chemicals away from children and pets.
14. The pH and chemical balance of the water must be maintained as explained in this manual (see page 13). Failure to do so may cause injury to users or damage to the spa jet unit, and will void the warranty.
2. Use the RESTORATION 600 only as described in this manual.
3. The RESTORATION 600 is intended for home use only. Do not use the spa in any commercial, rental, or institutional setting.
15. The water pump in the spa jet unit must be primed before you use the RESTORATION 600 the first time. You must also prime the pump before using the unit each time you re-fill the spa. The spa jet unit may be seriously damaged if the pump is not properly primed (see PRIMING THE SPA JET UNIT on page 10).
4. Use the RESTORATION 600 only on a level surface. Do not use the spa on carpet or other materials that could be damaged by moisture. Do not use the spa on rough or sharp surfaces such as gravel or wood chips.
16. DANGERÑWhen connecting the power cord (see PLUGGING IN THE RESTORATION 600 on page 10), plug the power cord directly into a grounded circuit capable of carrying 15 or more amps. No other appliance should be on the same circuit. Replace the power cord immediately if damaged.
5. The RESTORATION 600 will weigh approximately 2400 pounds when it is assembled and filled with water. Be sure that the location you select for the spa will support this weight, plus the weight of the occupants.
6. Inspect and tighten all parts regularly. Replace any worn parts immediately.
17. Do not use an extension cord with the RESTORATION 600. This could damage the motor and will void the warranty.
7. DANGERÑRisk of injury: Do not remove or alter the covers on the suction fittings. Never operate the RESTORATION 600 if the suction guard is missing or broken. Keep hair and body away from the suction guard. If you need to replace a suction fitting, be sure that the flow rate of the replacement is compatible.
18. DANGERÑIf you will be using the RESTORATION 600 outside, do not bury the power cord; you should also keep the power cord away from lawn mowers, hedge trimmers, and other similar equipment.
8. Do not bring any object into the RESTORATION 600 that could puncture the liner.

19. WARNINGÑThe power cord is equipped with a Ground Fault Circuit Interrupter (GFCI), located at the end of the power cord. The GFCI must be tested before each use. To test the GFCI, press the ÒtestÓ button while the spa jet unit is running. The spa jet unit should shut off. Press the ÒresetÓ button. The spa jet unit should resume normal oper- ation. If the spa jet unit continues to run after the ÒtestÓ button is pressed, then the GFCI is damaged. Do not use the RESTORATION 600 until the GFCI has been repaired or replaced by a qualified electrician.

9. Never insert any object into any opening.
10. Do not sit on the spa cover or place objects on it. It is not designed to support weight.
11. Remove any water which may collect on the spa cover.
12. Keep children and pets away from the RESTORATION 600 when it is not in use.
Page 4 of the ProForm PFHS60070 user manual — SAVE THESE INSTRUCTIONS
Page 4 · click to enlarge
Page 4
20. Keep all electrical appliances such as radios, telephones, televisions, and lights at least five feet (1.52 meters) away from the water.
27. WARNINGÑTo reduce the risk of injury: Pregnant women should consult with their physician before using the RESTORATION 600. Pregnant women should not use the spa if the water temperature is above 100¡F (38¡C); the unborn child could be seriously harmed.
21. A wire connector is provided on the pump motor of this unit to connect a minimum No. 8 AWG (804 mm 2 ) solid copper conductor between this unit and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet (1.52m) of the unit.

28. DANGERÑTo reduce the risk of drowning: Prolonged immersion in the RESTORATION 600 may cause hyperthermia, a dangerous condition which occurs when the internal body temperature rises several degrees above the normal body temperature of 98.6¡F. The symptoms of hyperthermia are nausea, dizziness, drowsiness, and fainting. Effects include: a lack of awareness, inability to per- ceive heat or danger, and a greater risk of drowning due to a loss of consciousness. Special note: Individuals suffering from hyperthermia may be unable to realize that they must exit the spa, and they also may be physically unable to do so.

22. DANGERÑRisk of electric shock: Do not set up the RESTORATION 600 within five feet of any metal objects or surfaces. As an alternative, you may use the spa within five feet of metal objects if each metal object is permanently connected to the wire connector on the pump motor of this unit by a minimum No. 8 AWG (804 mm 2 ) solid copper conductor (see instruction 21).
23. DANGERÑRisk of drowning: Exercise extreme caution to prevent unauthorized and unsupervised use of the RESTORATION 600 by children. Children must always be supervised.
29. WARNINGÑTo reduce the risk of drowning: Heat from the water, in conjunction with alcohol or drugs can cause unconsciousness. Do not use the RESTORATION 600 if you are under the influence of drugs or alcohol.
24. DANGERÑTo reduce the risk of drowning: ¥ Never use the spa alone; ¥ Children should not use the spa unless
30. WARNINGÑTo reduce the risk of injury or drowning: Consult your physician about possible side-effects of any medications you may be taking before using the RESTORATION 600. Heat from the water, in conjunction with some medications may cause drowsiness and increase the risk of drowning. Others can effect blood pressure, heart rate, and circulation.

they are supervised by an adult; ¥ Keep pets away from the spa at all times; ¥ Always replace and lock the spa cover

when the spa is not in use.

25. WARNINGÑTo reduce the risk of injury: The water temperature should never exceed 104¡F (40¡C). Temperatures between 100¡F (38¡C) and 104¡F (40¡C) are considered to be safe for healthy adults. However, if you plan to remain in the RESTORATION 600 for more than 10 to 15 minutes, a lower temperature is recommended. Lower temperatures are also recommended for children.
31. WARNINGÑTo reduce the risk of injury: It is especially important for persons over the age of 35 or persons with pre-existing health problems, such as obesity, heart disease, high or low blood pressure, circulatory problems, or diabetes to consult your physician before using this product.
26. WARNINGÑTo reduce the risk of injury: Always use an accurate thermometer to determine the water temperature before using the RESTORATION 600.
32. If you feel pain or dizziness at any time while using the RESTORATION 600, discontinue use and contact a physician.

SAVE THESE INSTRUCTIONS

Page 5 of the ProForm PFHS60070 user manual — WARNING LABEL IDENTIFICATION
Page 5 · click to enlarge
Page 5

WARNING LABEL IDENTIFICATION

The warning labels shown below have been placed on the spa cover, printed inside the inflatable spa liner, and placed on the side of the spa jet unit of the RESTORATION 600. Locate the labels and familiar- ize yourself with this information. The label on the side of the spa jet unit is an adhesive decal. If this decal is missing, or if it is not legible, please call our Customer Service Department toll-free at 1-800- 999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time, to order a replacement decal. Apply the decal in the location shown.

ProForm PFHS60070 — WARNING LABEL IDENTIFICATION diagram (page 5)
Fig. 1
Page 6 of the ProForm PFHS60070 user manual — BEFORE YOU BEGIN
Page 6 · click to enlarge
Page 6

BEFORE YOU BEGIN

Thank you for selecting the PROFORM¨ RESTORA- TION 600. The innovative RESTORATION 600 offers the features and quality of a traditional hot tub at an affordable price. Best of all, the RESTORATION 600 is fully portable, so you can take it wherever there is an electrical outlet. The RESTORATION 600 allows you to relax and unwind in the comfort of your own home.

Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please note the product model number and serial number before calling. The model number is PFHS60070. The serial number can be found on a decal attached to spa jet unit (see the front cover of this manual).

For your benefit, read this manual carefully before using the PROFORM¨ RESTORATION 600. If you have additional questions, please call our Customer

Before reading further, please familiarize yourself with the parts that are labeled in the drawing below.

Console (Under Spa Cover)

Ground Fault Circuit Interrupter (GFCI)

Inflation Valve Locking Buckle

Spa Cover · Spa Jet Unit · Power Cord

Page 7 of the ProForm PFHS60070 user manual — CHOOSING A LOCATION FOR THE RESTORATION 600
Page 7 · click to enlarge
Page 7

CHOOSING A LOCATION FOR THE RESTORATION 600

There are many factors to consider when choosing a location to set up the RESTORATION 600. These factors vary depending on whether you use the RESTORATION 600 inside or outside. We have listed several factors you may wish to consider as you decide where you want to use the RESTORATION 600.

If you set up the RESTORATION 600 inside:

If you set up the RESTORATION 600 outside:

1. The RESTORATION 600 will increase the level of humidity in your home. The location you choose should be well ventilated. You may need to install a ventilation fan or use a dehumidifier.
1. You should check your local building codes concerning the use of outdoor spas.
2. The location must be close to an electrical outlet. Do not use an extension cord with the RESTORATION 600.
2. The location must be close to an electrical outlet. Do not use an extension cord with the RESTORATION 600.
3. The RESTORATION 600 should be close to a source of water.
3. The RESTORATION 600 should be close to a source of water.
4. We recommend that you place the RESTORATION 600 on a waterand stain-resistant, non-slip surface.
4. Do not use the RESTORATION 600 on carpet or other material that may be damaged by moisture. We recommend that you place the RESTORATION 600 on a waterand stain-resistant, non-slip surface with a floor drain for any water that may splash from the RESTORATION 600.
5. Be sure that the location you choose is stable. It must be able to support the weight of the RESTORATION 600 when it is filled with water, plus the weight of the occupants. The RESTORATION 600 weighs approximately 2400 pounds when filled with water.
5. Be sure that the location you choose is stable. It must be able to support the weight of the RESTORATION 600 when it is filled with water, plus the weight of the occupants. The RESTORATION 600 weighs approximately 2400 pounds when filled with water.
6. Think about environmental factors, such as rain, wind, shade, sunlight, and so forth.
7. You should be able to monitor the use of the RESTORATION 600 from your home, to prevent unauthorized use by children.
6. Do not use the RESTORATION 600 above a finished living area, due to the risk of water damage.
8. Be sure that there is room around the RESTORATION 600 to permit servicing of the unit. The diameter of the tub is 69Ó. You should allow for this size, plus the size of the spa jet unit, when choosing the location.
7. Be sure that there is room around the RESTORATION 600 to permit servicing of the unit. The diameter of the tub is 69Ó. You should allow for this size, plus the size of the spa jet unit, when choosing the location.
9. Be sure to note any other considerations, such as aesthetics or privacy concerns, which may affect the safety or enjoyment of using the RESTORATION 600.
8. Be sure to note any other considerations, such as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the RESTORATION 600.
Page 8 of the ProForm PFHS60070 user manual — ASSEMBLY
Page 8 · click to enlarge
Page 8

ASSEMBLY

Before beginning assembly, carefully read the following information and instructions:

¥ Assembly requires the included air pump.

¥ Read each assembly step before you begin.

¥ Assembly requires two people.

¥ During assembly, make sure that all parts are ori-

¥ Place all parts in a cleared area and remove the

ented as shown in the drawings.

packing materials; do not dispose of the packing materials until assembly is completed.

1. Before beginning assembly, be sure that you have read and understand the information in the box above and on the previous page.

Unfold the Inflatable Spa Liner (9). Attach the nozzle on the air pump to the valve on the side of the Inflatable Spa Liner. Use the foot pedal on the air pump to fill the sides of the Inflatable Spa Liner with air.

Attach the nozzle on the air pump to the valve on the floor of the Inflatable Spa Liner (9). Use the air pump to fill the bottom of the Inflatable Spa Liner with air.

Attach the nozzle on the air pump to the valve on the top of the Inflatable Spa Liner (9). Use the air pump to fill the cushion on the top of the Inflatable Spa Liner with air.

2. Unfold the Fabric Spa Surround (8). Be sure that the indicated flap is on the outside of the Fabric Spa Surround. Insert the Inflatable Spa Liner (9) into the Fabric Spa Surround. Align the valve in the Inflatable Spa Liner with the hole in the Fabric Spa Surround.

Flip the flap on the Fabric Spa Surround (8) over the low section of the Inflatable Spa Liner (9).

Valve must be visible in this hole

Be sure that all six cover buckles are fully inserted through the loops in the Fabric Spa Surround (8).

3. Remove the power cord from the Spa Jet Unit (13).

With the help of a second person, place the Spa Jet Unit (13) over the Fabric Spa Surround (8) and the section of the Inflatable Spa Liner (9) which does not have the cushion. Be extremely careful not to tear the Inflatable Spa Liner (9) as you slide the Spa Jet Unit into place.

Show 9 more labels / short text on this page
Inflate here · second · Inflate here · third · Inflate here · first · Flap · Power · Cord
Page 9 of the ProForm PFHS60070 user manual — ASSEMBLY
Page 9 · click to enlarge
Page 9
ON 600, be sure that nd that it can be ease RESTORATION ed to be drained to lean water source, N 600, until the jet Jet Unit (13) are covRESTORATION water. is full, you must efore using the MING THE SPA JET the mesh pocket on r (11). inflation tube into Inflate the Support Support Ball (4) is be from the Support ough the mesh into the ball plug will e. not a toy. the Fabric Spa Liner (9), and the t the Spa Cover is e straps on the raps on the Fabric the Spa Cover (11) n the Fabric Spa4 9 13 5 11 Mesh Pocket 4 A B Inflation Tube 4Ball Plug 4 6 11 13 8 Latches and Buckles
ProForm PFHS60070 — ASSEMBLY diagram (page 9)
Fig. 2
Page 10 of the ProForm PFHS60070 user manual — TESTING AND TREATING THE WATER
Page 10 · click to enlarge
Page 10

USING THE RESTORATION 600

The RESTORATION 600 is designed for up to four adults. The six water jets can be regulated to provide a relaxing massage to sooth away stress, and the strength of the water massage can be adjusted by the air control. The RESTORATION 600 holds 300 gal- lons of water and offers an automatic, programmable heating (70¡F to 104¡F) and filtration system.

When connecting the power cord, plug the power cord directly into a grounded circuit capable of carrying 15 or more amps. No other appliance should be on the same circuit. Replace the power cord immediately if it becomes damaged.

The power cord is equipped with a Ground Fault Circuit Interrupter (GFCI), located at the end of the power cord. You should always test the GFCI before using the RESTORATION 600.

The guidelines below explain how to properly use the RESTORATION 600. Follow these guidelines to main- tain the spa for your long-term enjoyment.

First, turn on the RESTORATION 600 by pressing the power button on the console. Once the unit is run- ning, press the GFCI ÒtestÓ button. The RESTORA- TION 600 should shut off. Press the ÒresetÓ button. The RESTORATION 600 should resume normal oper- ation. If the RESTORATION 600 continues to run after the ÒtestÓ button is pressed, then the GFCI is dam- aged. Do not use the RESTORATION 600 until the GFCI has been repaired or replaced by a qualified electrician.

PRIMING THE SPA JET UNIT

The water pump in the spa jet unit must be primed before you use the RESTORATION 600 the first time. You must also prime the pump before using the unit each time you re-fill the RESTORATION 600.

To prime the spa jet unit, remove the primer cap from the console. Fill the spa jet unit with at least 64 oz. of water. Replace and tighten the primer cap. IMPOR- TANT: The spa jet unit may be seriously damaged if the pump is not properly primed, or if the primer cap is not replaced and fully tightened.

STARTING THE RESTORATION 600

Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONSOLE on the next page). The pumping unit will heat the water as it pumps. Cover the RESTORA- TION 600 with the spa cover. The spa cover must be tight. The water will heat at about 1.7¡F an hour with the cover on. If you are using the RESTORA- TION 600 indoors, and the room temperature is main- tained at 70¡F, it will take approximately 20 to 28 hours for the water to reach the set temperature.

PLUGGING IN THE RESTORATION 600

Once the RESTORATION 600 is filled with enough water to cover the water jets and the pump has been primed, the power cord can be plugged in and the spa jet unit can be turned on. Note: The first time the power cord is plugged in, the spa jet unit will turn on automatically.

The temperature and water flow can be set or changed by the controls on the console (see USING THE CONSOLE on the next page).

TESTING AND TREATING THE WATER

ProForm PFHS60070 — TESTING AND TREATING THE WATER diagram (page 10)
Fig. 3

The RESTORATION 600 comes with a starter chemi- cal pack for maintaining the water in the spa. Disregard the directions on the individual packages of ÒQUICK pHix It DOWNÓ and ÒQUICK pHix It UP.Ó However, the directions on the bottle of ÒNon-chlorine ShoxÓ and ÒBromine BaseÓ are correct. Always keep the chemicals away from children and pets.

The first time you use the spa, you should test and treat the water. Once you have verified that the spa jet unit is functioning properly, and have allowed the water to circulate for a while, you should remove the spa cover and add 1/3 of the ÒBromine BaseÓ bottle,

Primer · Cap

Page 11 of the ProForm PFHS60070 user manual — SECURING THE SPA COVER
Page 11 · click to enlarge
Page 11

and 1/3 of the ÒNon-chlorine ShoxÓ bottle to the water in the spa. Allow the water to circulate for five min- utes. You should now test the pH level of the water. Use the included test strips to check the pH of the water. Refer to the instructions on the test strip pack- aging to see how to use the test strips.

SECURING THE SPA COVER

The spa cover can be secured by snapping the latch- es on the spa cover into the buckles on the side pan- els.

ProForm PFHS60070 — SECURING THE SPA COVER diagram (page 11)
Fig. 4

The buckles can be locked by inserting the key and turning it clockwise a quarter turn. To unlock the buckles, insert the key and turn it counter- clockwise a quarter turn.

If the level is too low, add half of one of the ÒQUICK pHix It UPÓ packets to the water. Let the water circu- late through the spa jet unit for five minutes. Test the pH level again. Repeat until the pH level is correct.

If the level is too high, add half of one of the ÒQUICK pHix It DOWNÓ packets to the water. Let the water cir- culate through the spa jet unit for five minutes. Test the pH level again. Repeat until the pH level is cor- rect.

Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children.

Replace the spa cover and allow the water to contin- ue to heat.

See WATER CHEMISTRY on page 13 for information concerning proper water maintenance.

ProForm PFHS60070 — SECURING THE SPA COVER diagram (page 11)
Fig. 5

speed, providing more intense hydrotherapy. Press the button a third time and the spa jet unit will shut off.

Refer to the console diagram above. The function of each console control is explained below:

The spa jet unit also features an automatic mode, which heats and filters the water when the spa is left unattended. When the spa jet unit is first plugged in, or if the buttons on the console have not been used for longer than twenty minutes, the automatic mode will begin filtering or heating the water, as needed. Note: to keep the filter and heat cycles from run- ning, the power cord must be unplugged.

Primer: This opening allows you to prime the spa jet unit before operation (see PRIMING THE SPA JET UNIT on page 10).

Thermostat: Controls the temperature of the water. The water heats at about 1.7¡F an hour with the cover on. The thermostat can be set to heat the water from 70¡F to 104¡F. Use a medical or other accurate ther- mometer to check the temperature of the water.

Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase. If the control is turned to the right, the amount will decrease.

On/Off: Turns the spa jet unit on and off. When you first press the on/off button, the spa jet unit will run at low speed, providing gentle hydrotherapy. Press the button again and the spa jet unit will run at high

Page 12 of the ProForm PFHS60070 user manual — D
Page 12 · click to enlarge
Page 12

SPA JET UNIT OPERATION

ing the water for twenty minutes to filter any impuri- ties. Also, if the water temperature falls below 40¡F, the pump will begin circulating and heating the water to prevent the water from freezing.

The spa jet unit features three hydro-therapy jets, a whirlpool jet, a suction vent, and a filter housing.

The three hydro-therapy jets (A), located on the front of the spa jet unit, focus the water massage on your neck and back.

DRAINING THE RESTORATION 600

To drain the RESTORATION 600, you must use a garden hose to siphon the water. Place one end of the hose in the spa and hold it in front of a hydro- therapy jet until there is a flow of water coming out of the hose. Turn off the spa unit and unplug the power cord. The unit will be damaged if it is run without water circulating. Be sure the end of the hose in the spa is on the floor of the spa.

B

A

D

The whirlpool jet (B), located on the left side of the spa jet unit, directs the flow of the water to create a whirlpool action in the RESTORATION 600.

The suction vent (C), located on the right side of the spa jet unit, pulls the water into the spa unit, in order to operate the system. The suction cover should always be in place over the suction vent. Never operate the spa with- out the suction cover in place.

DRAINING THE PUMP

After the RESTORATION 600 is drained (see DRAIN- ING THE RESTORATION 600 above), the pump in the spa jet unit should also be drained if the spa will be stored for more than thirty days, or if it may be exposed to freezing temperatures.

To drain the pump, remove the spa jet unit from the side pan- els. Be careful not to tear the inflatable spa liner. Locate the pump inside the spa jet unit. Remove the drain plug from the pump. Tip the spa jet unit slightly, until all the water has drained from the pump. Replace the drain plug.

The filter (D), is locat- ed on the left side of the spa jet unit, behind the filter cover. The filter can be removed for cleaning and replacement by removing the Filter Cover and the two filter cover screws and then pulling the filter from the spa jet unit.

D

The spa jet unit features an automatic filter cycle and freeze protection. If the spa jet unit has not been operated for three hours, the pump will begin circulat-

Show 5 more labels / short text on this page
Filter Cover · Pump · Screws · Filter Cover · Drain Plug
Page 13 of the ProForm PFHS60070 user manual — WATER CHEMISTRY
Page 13 · click to enlarge
Page 13

MAINTENANCE

CLEANING THE INFLATABLE SPA LINER

4. Do not exceed the recommended amountsÑfollow the directions on the label closely. 5. Keep all containers closed tightly when not in use. 6. Never add water to the chemicalsÑalways add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place.

The liner should be cleaned with a mild soap solution. Do not use solvents. The liner should always be clean and dry before being moved or stored.

CHECKING AND CLEANING THE FILTER

The filter should be checked periodically for build-up of dirt and oil. If the filter needs to be cleaned, follow the steps below:

MAINTAINING THE PROPER PH BALANCE

1. Turn off the power. 2. Remove the two screws and cover from the spa jet. Then pull the filter out of the unit. 3. Check the filter for any dirt or debris. If the fil- ter needs to be cleaned, rinse the filter with a hose. If the filter still is dirty, you will need to soak it in a cleaning solution which can be obtained from a pool and spa supply store. 4. Inspect the filter for damage. Replace the fil- ter if there are any signs of damage. 5. Re-insert the cleaned filter and re-attach the two screws and cover to the spa jet unit.

The pH factor is a measure of relative acidity or alka- linity in the water. It is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the RESTORATION 600.

Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build-up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.

MAINTAINING THE SPA COVER

The spa cover should be cleaned monthly. Remove the inflatable cover from the spa cover, then hang the spa cover over a clothes line and spray it with a hose. Leave the cover on the clothes line until it is fully dry.

To maintain the proper pH level, you should test the pH of the water regularly. To test the water you can either purchase additional test strips or purchase a pH test kit at a pool and spa supply store. The pH read- ing should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisul- fate). Test the water again after five minutes. See the instructions with your test strips or pH test kit for addi- tional information about testing and adjusting the pH.

WINTER USE AND CARE

The RESTORATION 600 is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. (See DRAINING THE RESTORATION 600 and DRAINING THE PUMP on page 12.)

WATER CHEMISTRY

SANITIZING THE RESTORATION 600

The RESTORATION 600 comes with a starter chemi- cal pack for maintaining the water in the spa. (See TESTING AND TREATING THE WATER on page 10.) Additional chemicals can be purchased at a pool and spa supply store.

Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.

The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, water conditions, and so forth.

1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Keep all chemicals out of the reach of children and pets.

Proper water maintenance is a fairly complex process. We recommend that you contact your local pool and spa supplier for information on how you should best accomplish this.

Page 14 of the ProForm PFHS60070 user manual — 6. SYMPTOM: THE WATER DOES NOT HEAT
Page 14 · click to enlarge
Page 14

TROUBLE - SHOOTING

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time.

1. SYMPTOM: THE SPA WILL NOT OPERATE

with the spa cover. The spa cover must be tight. Set the air control to low. The water will heat at a rate of 1.7¡F an hour. If you are using the spa indoors, and the room temperature is maintained at 70¡F, it will take approximately 20 to 28 hours for the water to reach the set temperature.

a. Check the power cord. The power cord must

be plugged into a grounded outlet (see PLUG- GING IN THE RESTORATION 600 on page 10).

b. Check to see if the GFCI breaker is tripped, or

was not turned on. Reset the GFCI breaker.

b. If you are using the RESTORATION 600 out-

doors, it may take longer for the water to heat. See the chart below for the approximate heat- ing time.

2. SYMPTOM: THE CIRCUIT BREAKER OR GFCI BREAKER TRIPS WHILE THE SPA IS OPERATING

Air Temperature Heating Time 70¡F + 20 to 28 hours 50¡FÐ70¡F 1 to 2 days 30¡FÐ50¡F 2 to 3 days

a. Reset the circuit breaker. If the circuit breaker

trips again, contact a qualified electrician for service.

3. SYMPTOM: THE PUMP HUMS

b. If the water still has not heated after three

days, contact our customer service department.

a. The filter may be dirty or damaged. Remove

the filter housing from the spa jet unit and clean or replace the filter.

7. SYMPTOM: THE WATER IS NOT BEING CLEANED BY THE FILTER

b. The pump may have a foreign object stuck in

a. Check to see if the filter is in place. Clean the

the impeller. Contact our customer service department.

filter if it is dirty.

b. Check the chemical balance of the water. If the

c. The pump may have a loose wire connection.

pH is incorrect, the sanitizing agents will not function properly.

Contact our customer service department.

4. SYMPTOM: THE PUMP HUMS BUT DOES NOT ROTATE
8. SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW

a. The pump may be jammed. Contact our cus-

a. Adjust the water level. This usually occurs only

tomer service department.

when the water level is low. Add water until the filter and jets are covered.

5. SYMPTOM: THE PUMP IS NOISY WHILE OPERATING

b. This problem is caused by excess air in the

pump circulation system. Check to see if the primer cap is fully tightened. Prime the pump again and fully tighten the primer cap (see PRIMING THE SPA JET UNIT on page 10).

a. There may be debris in the pump. Contact our

customer service department.

b. The pump may have a bad bearing. Contact

our customer service department.

9. SYMPTOM: THE SPA JET UNIT CAVITATES DURING USE

6. SYMPTOM: THE WATER DOES NOT HEAT

a. Adjust the water level. This usually occurs only

a. The heater is attached to the pump in the spa

when the water level is low. Add water until the filter and jets are covered.

jet unit. If the pump is operating, the water should heat. Cover the RESTORATION 600

Page 15 of the ProForm PFHS60070 user manual — 12. SYMPTOM: THE INFLATABLE SPA LINER LOSES AIR
Page 15 · click to enlarge
Page 15

b. This problem is caused by excess air in the

11. SYMPTOM: THE WATER LEVEL DROPS

pump circulation system. Check to see if the primer cap is fully tightened. Prime the pump again and fully tighten the primer cap (see PRIMING THE SPA JET UNIT on page 10).

a. Some water loss due to evaporation is normal.

If rapid water loss occurs, or if you notice wet- ness on the floor around the RESTORATION 600, then the liner may have a leak. Locate the leak, and patch it using a pool patch kit that you can purchase at any pool and spa supply store.

10. SYMPTOM: THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF

a. When you press the on/off button once, the spa

jet unit will run at low speed, heating the water. Press the button again and the spa jet unit will run at high speed, filtering the water. Press the button a third time and the spa jet unit will shut off. The spa jet unit also features an automatic mode, which heats and filters the water when the spa is left unattended. When the spa jet unit is first plugged in, or if the buttons on the console have not been used for longer than twenty minutes, the automatic mode will begin filtering or heating the water, as needed. To keep the filter and heat cycles from running, the power cord must be unplugged. Special Note: If the unit is to be kept outdoors in cold weather, you must allow the spa to maintain a safe temperature by running in automatic mode. Allowing the spa jet unit to freeze will damage the unit. If you do not want to use the spa during the winter, store it in a warm, dry location (see WINTER USE AND CARE on page 13).

b. A clamp or seal inside the spa jet may be

loose. Check the floor around the spa jet unit for excess water, and watch the spa jet unit while it is operating to see if water drips from the spa jet unit housing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.

12. SYMPTOM: THE INFLATABLE SPA LINER LOSES AIR

a. Over time, some air loss is normal. If rapid air

loss occurs, then the liner may have an air leak. Locate the leak, and patch it using a pool patch kit that you can purchase at any pool and spa supply store.

Page 16 of the ProForm PFHS60070 user manual — ORDERING REPLACEMENT PARTS
Page 16 · click to enlarge
Page 16

ORDERING REPLACEMENT PARTS

To order replacement parts, simply call our Customer Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be pre- pared to give the following information when calling:

1. The MODEL NUMBER of the product (PFHS60070).
2. The NAME of the product (PROFORM ¨ RESTORATION 600).
3. The SERIAL NUMBER of the product (see the front cover of this manual).
4. The KEY NUMBER and DESCRIPTION of the part(s) (see the PART LIST/EXPLODED DRAWING attached to the center of this manual).

Part No. 145322 H00449-C R0398A Printed in USA © 1998 ICON Health & Fitness, Inc.

Page 17 of the ProForm PFHS60070 user manual — PART LISTÑModel No. PFHS60070 R0398A
Page 17 · click to enlarge
Page 17

PART LISTÑModel No. PFHS60070 R0398A

Key No. Qty. Description

Key No. Qty. Description

1 1 Power Cord Grommet 2 1 Motor Cap Screw 3 1 Dual Temperature Probe 4 1 Inflatable Cover 5 4 Clamp Screw 6 4 Clamp 7 4 Bolt 8 1 Fabric Spa Surround 9 1 Inflatable Spa Liner 10 4 Spa Jet Nozzle 11 1 Spa Cover 12 2 Heater O-ring 13 1 Spa Jet Unit 14 1 Heater Housing 15 2 Filter Cover Screw 16 1 Filter 17 1 Cover Screw 18 1 Suction Cover 19 1 Suction Fitting 20 1 Pump Motor 21 1 Heater Terminal Cover 22 1 Heat Controller 23 1 Heater Wire Harness 24 2 Cover Nut 25 1 Electronic Control 26 1 Motor Endcap 27 1 Headrest w/Fasteners 28 4 Nut 29 1 Heat Control Nut 30 4 Rubber Insulator

31 4 Washer 32 1 Primer O-ring 33 1 Rubber Damper 34 1 Wire Harness 35 1 Air Control Knob 36 1 On/Off Switch Assembly 37 1 Thermostat Knob 38 1 Primer Cap 39 16 Housing Screw 40 1 Console Overlay 41 1 Micro Switch/Wire 42 2 Control Mounting Screw 43 2 Control Mounting Nut 44 1 Motor Mount Bracket 45 2 Housing Support Bracket 46 5 Cable Clamp 47 1 Filter Cover 48 2 3/8Ó Compression Fitting 49 1 Temperature Tube 50 5 Trim 51 2 #10 Washer # 1 Heater Ground Wire # 1 Air Pump # 2 Key # 1 Starter Chemical Pack # 1 Chemical Test Strip Pack # 1 Warning Decal # 1 UserÕs Manual # 1 Video

Ask about the ProForm PFHS60070

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the ProForm PFHS60070

Be the first to ask — other owners or our team will answer.

Original document

ProForm PFHS60070 manual PDF

17 pages·881 KB·Hot Tub·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…