EN
ProForm logo
Official user manual

ProForm PFSB62830

20 pages·635 KB·Hot Tub·PDF·ENDEFRITNLJA
ProForm PFSB62830
Table of Contents 44 sections Table of Contents · Posting the Warning Sign · Important Safety Instructions · READ AND FOLLOW ALL INSTRUCTIONS · … ShowHide
Page 1 of the ProForm PFSB62830 user manual
Page 1 · click to enlarge
Page 1
ProForm PFSB62830 diagram (page 1)
Fig. 1
ProForm PFSB62830 diagram (page 1)
Fig. 2
Model No. PFSB62830 Serial No. The serial number is on a sign behind the access panel. Write the serial number in the space above. Access PanelUSER’S MANUAL QUESTIONS? If you have questions, or if there are missing parts, we will guarantee complete satisfaction through direct assistance from our factory. TO AVOID DELAYS, PLEASE CALL DIRECT TO OUR TOLLFREE CUSTOMER HOT LINE. The technicians on our customer hot line will provide immediate assistance, free of charge. CUSTOMER HOT LINE: 1-877-897-7493 Mon.–Fri., 8 a.m.–5 p.m. CST CAUTION Read all precautions and instructions in this manual before using this equipment. Save this manual for future reference.
Page 3 of the ProForm PFSB62830 user manual — READ AND FOLLOW ALL INSTRUCTIONS
Page 3 · click to enlarge
Page 3

Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions.
10. Never insert any object into any opening.
11. Do not use breakable containers in or near the hydrotherapy spa.
2. Use the hydrotherapy spa only as described in this manual.
12. Do not sit on the spa cover or place objects on it; it is not designed to support weight.
3. The hydrotherapy spa is intended for home use only. Do not use the spa in a commercial, rental, or institutional setting.
13. Remove any water or debris that may collect on the spa cover.
14. Keep children under the age of 12 and pets away from the hydrotherapy spa when it is not in use.
4. Use the hydrotherapy spa only on a level surface. Do not use the spa on carpet or other materials that could be damaged by moisture.
5. The hydrotherapy spa will weigh approximately 3,300 pounds when it is filled with water. Make sure that the location you select for the spa will support this weight, plus the weight of the occupants.
15. Keep all chemicals away from children and pets.
16. The pH and chemical balance of the water must be maintained as explained in this manual (see pages 10 and 14). Failure to do so may cause injury to users or damage to the hydrotherapy spa, and will void the warranty.
6. Inspect and tighten all parts regularly. Replace any worn parts immediately.
7. DANGER—Risk of injury: Do not remove or alter the covers on the suction fittings. Never operate the hydrotherapy spa if the suction guard is missing or broken. If you need to replace a suction fitting or pump, make sure you use only manufacturer recommended replacement parts. Keep hair and body parts away from the suction guard. Do not allow long hair to float freely in the water; long hair should be restrained with a bathing cap.
17. Individuals with infections and open sores or wounds should not use the hydrotherapy spa. Bacteria thrive in warm and hot water. Always keep your spa disinfected and maintain the proper chemical balance.
18. Shower before and after using the hydrotherapy spa. This will remove any deodorant, perspiration, or body oils that could contaminate the water. Showering after will remove any residual chemicals and any bacteria that may have been in the spa.
8. IMPORTANT: Do not allow the hydrotherapy spa to be exposed to direct sunlight when it is empty. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under the warranty.
19. WARNING—The Ground Fault Circuit Interrupter (GFCI), must be tested before each use. To test the GFCI, press the “test” button while the hydrotherapy spa is running. The spa should shut off. Press the “reset” button. The spa should resume normal operation. If the spa continues to run after the “test” button is pressed, then the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.
9. Do not bring any object into the hydrotherapy spa that could damage the spa shell.
Page 4 of the ProForm PFSB62830 user manual — Important Safety Instructions
Page 4 · click to enlarge
Page 4
20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, telephones, televisions, and lights at least five feet away from the water.

physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy.

21. A wire connector is provided on the electronics pack of the hydrotherapy spa to connect a minimum No. 6 AWG (13.3 mm 2 ) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa.

29. DANGER—To reduce the risk of drowning: Prolonged immersion in the hydrotherapy spa may cause hyperthermia. The causes, symp- toms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F. The symp- toms of hyperthermia include an increase in the internal temperature of the body, dizzi- ness, lethargy, drowsiness and fainting. The effects of hyperthermia include failure to per- ceive heat; failure to recognize the need to exit the spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub and unconsciousness resulting in danger of drowning. WARNING: The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia.

22. DANGER—Risk of electric shock: Do not set the hydrotherapy spa within five feet of any metal objects or surfaces. As an alternative, you may use the spa within five feet of metal objects if each metal object is permanently connected to the wire connector on the electronics pack of the spa by a minimum No. 6 AWG (13.3 mm 2 ) solid copper conductor (see instruction 21).
23. Do not operate the pump motor when the hydrotherapy spa is empty. The pump motor may be seriously damaged if it is operated without water circulating.
24. DANGER—Risk of drowning: Exercise extreme caution to prevent unauthorized and unsupervised use of the hydrotherapy spa by children. Children must always be supervised.
30. WARNING—To reduce the risk of drowning: Do not use the hydrotherapy spa if you are under the influence of alcohol or drugs. Heat from the water, in conjunction with alcohol or drugs, can cause loss of consciousness.
  • 25. DANGER—To reduce the risk of drowning:
  • Never use the hydrotherapy spa alone.
  • Children should not use the spa unless they are supervised by an adult.
  • Keep pets away from the spa at all times.
  • Always replace and lock the spa cover when the spa is not in use.
31. WARNING—To reduce the risk of injury or drowning: Consult your physician about possible side-effects of any medications you may be taking before using the hydrotherapy spa. Heat from the water, in conjunction with some medications, may cause drowsiness and increase the risk of drowning. Other medications can effect blood pressure, heart rate, and circulation.
26. WARNING—To reduce the risk of injury: The water temperature should never exceed 104°F. Temperatures between 100°F and 104°F are considered to be safe for healthy adults. However, if you plan to remain in the hydrotherapy spa for more than 10 to 15 minutes, a lower temperature is recommended. Lower temperatures are also recommended for children. Children should not be allowed to swim under the surface of the water in the spa.
32. Do not use the hydrotherapy spa immediately after strenuous exercise.
33. If you feel pain or dizziness at any time while using the hydrotherapy spa, discontinue use and contact a physician.
34. WARNING—To reduce the risk of injury: It is especially important for persons over the age of 35 or persons with pre-existing health problems, such as obesity, heart disease, high or low blood pressure, circulatory problems, or diabetes to consult their physician before using the hydrotherapy spa.
27. WARNING—To reduce the risk of injury: Before entering the hydrotherapy spa, always use an accurate thermometer to determine the water temperature.
28. WARNING—To reduce the risk of injury: Pregnant women should consult with their
Page 5 of the ProForm PFSB62830 user manual — SAVE THESE INSTRUCTIONS
Page 5 · click to enlarge
Page 5
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin.
36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.)
37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals.

SAVE THESE INSTRUCTIONS

Page 6 of the ProForm PFSB62830 user manual — Before You Begin
Page 6 · click to enlarge
Page 6

Before You Begin

Congratulations for selecting the new PROFORM®

For your benefit, read this manual carefully before using the hydrotherapy spa. If you have questions after reading the manual, please call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please mention the product model number and serial number when calling. The model number is PFSB62830. The serial number can be found on a decal on the access panel inside the spa (see the front cover of this manual).

SATURN hydrotherapy spa. The innovative SATURN spa allows you to enjoy all the benefits of hydrothera- py in the comfort and privacy of your home.

Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life. The warm environment stimulates blood flow, which is essential in the healing process, and the powerful massage action further eases tension and stress throughout the body. The PROFORM SATURN hydrotherapy spa gives you the specialized treatment you need to feel your best.

Before reading further, please familiarize yourself with the parts that are labeled in the drawing below.

Show 12 more labels / short text on this page
Console Jets Jets · Diverter Knob · Air Controls · Waterfall · Knob Spa Shell · Jets · Filter · Access · Panel · Panel · Locking · Buckle
Page 7 of the ProForm PFSB62830 user manual — Choosing a Location for the Hydrotherapy Spa
Page 7 · click to enlarge
Page 7

Choosing a Location for the Hydrotherapy Spa

There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.

If you set up the hydrotherapy spa inside:

If you set up the hydrotherapy spa outside:

1. The spa will increase the level of humidity in your home. The location you choose should be well ventilated. You may need to install a ventilation fan or use a dehumidifier.
1. Check local building codes concerning the use of outdoor spas.
2. The spa should be located near a power source capable of supplying 240 volts AC power. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 30 amps. No other appliance should be on the same circuit.
2. The spa should be located near a power source capable of supplying 240 volts AC power. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 30 amps. No other appliance should be on the same circuit.
3. The spa should be close to a source of water.
3. The spa should be close to a source of water.
4. We recommend that you place the spa on a waterand stain-resistant, non-slip surface. Do not use the spa on rough or sharp surfaces such as gravel or wood chips.
4. Do not use the spa on carpet or other material that may be damaged by moisture. We recommend that you place the spa on a waterand stain-resistant, non-slip surface with a floor drain for any water that may splash from the spa.
5. Be sure that the location you choose is stable. It must be able to support the weight of the spa when it is filled with water, plus the weight of the occupants. The spa weighs approximately 3,300 pounds when it is filled with water.
5. Be sure that the location you choose is stable. It must be able to support the weight of the spa when it is filled with water, plus the weight of the occupants. The spa weighs approximately 3,300 pounds when it is filled with water.
6. Consider environmental factors such as rain, wind, shade, and sunlight.
6. Do not use the spa above a finished living area, due to the risk of water damage.
7. You should be able to monitor the use of the spa from your home, to prevent unauthorized use by children. You may want to enclose the spa with a fence and self-latching gate to prevent unauthorized use.
7. Be sure that there is room around the spa to permit servicing of the unit. The dimensions of the spa are 80” W x 76” L x 36” H. You should allow for this size when choosing the location.
8. Be sure that there is room around the spa to permit servicing of the unit. The dimensions of the spa are 80” W x 76” L x 36” H. You should allow for this size when choosing the location.
8. The spa is not designed for in-floor installation. However, it is compatible with a deck system that is built flush with the top of the spa, provided you leave access to the motor for service.
9. The spa is not designed to be installed below ground level. However, it is compatible with a deck system that is built flush with the top of the spa, provided you leave access to the motor for service.
9. Be sure to note any other considerations, such as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the spa.

10.Be sure to note any other considerations, such as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the spa.

Page 8 of the ProForm PFSB62830 user manual — Assembly
Page 8 · click to enlarge
Page 8

Assembly

Before beginning assembly, carefully read the following information and instructions:

ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included):

  • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is operating.
  • One phillips screwdriver

A wire connector is provided on the electronics pack of the spa to connect a minimum No. 6 AWG (13.3 mm2) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa.

  • During assembly, make sure that all parts are oriented as shown in the drawings.
  • Read each assembly step before you begin.
  • Tighten all parts as you assemble them, unless instructed to do otherwise.
1. Before beginning assembly, make sure that you have read and understand the information in the box above and on the previous two pages.

Remove the four indicated #10 x 2” Sheet Metal Screws (7). Remove the indicated Access Panel (2) by sliding it down and then pulling the bottom away from the spa. Be careful not to damage the spa shell.

2. Locate the drain hose inside of the spa. Close the valve knob on top of the drain hose. Make sure that the cap is fully tightened onto the end of the drain hose.

Locate the four gate valves inside of the spa (two are shown). Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves. In addition, make sure that the six collars are tight (four are shown).

See step 1. Re-attach the Access Panel (2) with the four #10 x 2” Sheet Metal Screws (7).

Show 11 more labels / short text on this page
Spa Shell · Gate Valve · Collars · Collar Collar · Locking · Clip · Drain Hose · Valve Knob · Cap · Stem · Gate Valve
Page 9 of the ProForm PFSB62830 user manual — Assembly
Page 9 · click to enlarge
Page 9
3. Locate the three pillows. Each pillow can be attached to the spa shell in a high position or a low position. To determine the high and low positions, attach one pillow to the spa shell, note its position, remove it, turn it 180°, and then re-attach it. Attach the three pillows in the desired positions.

4. The spa operates on a 240 volt power source and must be wired directly to a 30 amp Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed electrician. A wiring diagram has been provided on the inside of the electronics package as a reference. Under no circumstances should the spa be wired by someone other than a qualified electrician. Before you have the spa wired, make sure that it is in the desired position and that it can be serviced, if needed.

5. Remove the two warning decals (not shown) from the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to service the spa. Once the spa is filled, it will have to be drained before it can be moved.

Insert a garden hose into the filter housing, and begin filling the spa. Do not use soft water. The spa may be filled with cold water; however, if warm or hot water is used, the spa will be ready for use sooner. Fill the spa until the water is at the level of the molded fill line. Do not overfill the spa.

Refer to the inset drawing. Set the Filter (16), the Cartridge Plug (49), the Diverter Plate (33), and the Basket (43) into the filter housing. Next, screw the Filter Cover (8) into the filter housing until it is fully seated.

6. Pull down one of the straps on the Spa Cover (11) and hold the Buckle (30) against one of the cedar panels on the spa. (Note: To position the Buckle cor- rectly, have a second person hold the strap on the opposite side of the Spa Cover tight.) The Spa Cover must be tight. Do not place the Buckle over the grooves between the cedar panels. Refer to the inset drawing. Remove the latch from the Buckle. Attach the Buckle to the cedar panel with two #4 x 3/4” Screws (31).

Attach the other three Buckles (30) to the cedar pan- els in the same way.

Remove the Spa Cover (11) from the spa.

Show 10 more labels / short text on this page
Pillow · Pillow · Pillow · Filter Housing · Filter Housing · Garden · Hose · Strap · Latch · Strap
Page 10 of the ProForm PFSB62830 user manual — STARTING THE HYDROTHERAPY SPA
Page 10 · click to enlarge
Page 10

Using the Hydrotherapy Spa

The hydrotherapy spa is designed to seat five adults. The spa holds 295 gallons of water and offers a heat- ing system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.

the jet button on the console (see USING THE CON- TROLS on page 12). Once the spa is running, press the GFCI “test” button. The spa should shut off. Press the “reset” button. The spa should resume normal operation. If the spa continues to run after the “test” button is pressed, the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.

WIRING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to operate with a 240 volt power source. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 30 amps. No other appliance should be on the same circuit. Connection of the spa to the 240 volt power source must be performed by a qualified, licensed electrician and must comply with all local, state, and federal electrical codes. The qualified, licensed electrician can refer to the instructions on the inside of the electronics package for information about con- necting the spa to a 240 volt power source.

Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONTROLS on page 12). The pumping unit will heat the water as it pumps. Cover the hydrotherapy spa with the spa cover. The spa cover must be tight (see SECURING THE SPA COVER ON THE SPA below). The water will heat at about 6°F per hour with the cover on. If you are using the spa indoors, and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.

Once the spa is filled with water, the power can be turned on. Note: The first time the power is turned on, the spa will start automatically.

The temperature and the water flow can be set or changed with the controls on the console (see USING THE CONTROLS on page 12).

TESTING AND TREATING THE WATER

SECURING THE SPA COVER ON THE SPA

The first time you use the spa, you should test and treat the water. You must also treat the water each time you refill the spa. A test strip and a chemical pack are available at your local pool and spa supplier. Follow the directions carefully on the chemical pack to test and treat the water. Always keep the chemicals away from children and pets.

To secure the spa cover, snap the latches on the spa cover into the buckles on the cedar panels.

To lock the buckles, insert the key and turn it clock- wise 1/4 turn. To unlock the buckles, insert the key and turn it counterclock- wise 1/4 turn. Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children.

See WATER CHEMISTRY on page 14 for information concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

You should always test the GFCI before using the hydrotherapy spa. First, turn on the spa by pressing

Latch · Key · Buckle

Page 11 of the ProForm PFSB62830 user manual — P
Page 11 · click to enlarge
Page 11

Spa Shell Diagram

P

A A

P

D

T

Q Q

K

Q

T

K

B

E

F

I J

T

G

A

H

O U N

L R S M

P

Refer to the diagram above. The function of each component is explained below.

I. The temperature probe monitors water tempera-

ture.

A. The four adjustable, directional jets can be pivot-

J. The underwater light can be used for night opera-

ed to direct their water flow. To open the jets, turn the rims counterclockwise; to close the jets, turn the rims clockwise. If no air flows through the jets, turn the jets counterclockwise. Close the jets to increase the water pressure to other jets.

tion (see USING THE CONTROLS on page 12).

K. The two suction vents near the floor of the spa

bring water into the pumps. Never operate the spa without the suction covers in place.

B. The adjustable, pulsing jet produces a soothing,

L, M. The air controls determine the air flow to the

pulsing massage action. To open the jet, turn the rim counterclockwise; to close the jet, turn the rim clockwise.

jets (see USING THE CONTROLS on page 12).

N. The filter can be removed for cleaning or replace-

ment (see CHECKING AND CLEANING THE FIL- TER on page 13).

C. The large rotary jet features two jets of water that

provide a pulsing, spinning massage action. Turn the jet counterclockwise to open it or clockwise to close it.

O. The console controls the jets, the light, and the

water temperature (see USING THE CONTROLS on page 12).

D. The two whirly jets provide a continuous, whirling

P. The three pillows can be removed or turned 180°

massage action.

to provide two positions of comfort.

E. The six small adjustable, directional jets can be

Q. The nine medium directional jets pinpoint the

pivoted to direct their water flow. Turn the rims of the jets to open and close them.

lower, middle, and upper sections of your back.

R. The waterfall valve adjusts the waterfall flow.

F. The volcano jet provides a powerful foot massage.

S. The waterfall creates a soothing sound and mas-

G. An optional ozone generator can be purchased and

sage.

installed to utilize the ozone jet. Ozone provides a way to help sanitize the spa with minimal chemical treatment.

T. The three adjustable twin-nozzle jets produce a

pulsating hydrotherapy action.

H. The skimmer cleans the surface of the water.

U. The diverter knob directs the water flow (see

USING THE CONTROLS on page 12).

Page 12 of the ProForm PFSB62830 user manual — M
Page 12 · click to enlarge
Page 12

Using the Controls

Temperature Down Button Temperature

Refer to the diagram above. The function of each control is explained below:

the jets labeled M. Air control L controls air flow to the jets labeled L. If a control is turned counterclockwise, the amount of air flowing through the jets will increase. If the control is turned clockwise, the amount of air will decrease.

Jet Button: Turns the spa jets on and off. If the but- ton is pressed once, the spa jets will run at low speed, providing gentle hydrotherapy. If the button is pressed again, the jets will run at high speed, providing more intense hydrotherapy. If the button is pressed a third time, the jets will shut off.

Waterfall Knob: Controls the flow of water through the waterfall.

Diverter Knob: Diverts the water flow two ways. If the knob is turned clockwise, water is diverted to the seats labeled 1, 2, and 4 below. If the knob is turned counterclockwise, water is diverted to the seats labeled 3 and 5 below and the volcano jet (see F on the SPA SHELL DIAGRAM on page 11). Note: The diverter knob may be difficult to turn while the pump is running at high speed.

The spa also features an automatic mode that heats and filters the water when the spa is left unattended. When the power to the spa is first turned on, or if the water temperature is below the set temperature, the water will be heated as required to maintain the set temperature. Note: To keep the filter and heat cycles from running, the power to the spa must be turned off.

Light Button: Turns the underwater light on and off.

Temperature Buttons: Control the temperature setting of the water. The temperature can be set between 80°F and 104°F. The water heats at about 6°F per hour with the cover on. Use a medical or other accu- rate thermometer to check the temperature of the water. Note: The word “COOL” will appear in the con- sole display if the temperature of the water is more than 20°F cooler than the set temperature. When this happens, the heater will automatically activate to warm the water. The word “ICE” will appear in the display if the temperature drops below 40°F. If this happens, the pump will automatically circulate the water and warm the plumbing to keep the water from freezing.

M

M

Air Controls: Determine the amount of air flowing through the spa jets during operation. Refer to the diagram at the right. Air control M controls air flow to

Show 9 more labels / short text on this page
Waterfall knob · Console · Air Control M · Display · Air Control L · Diverter Knob · Jet Button · Light Button · Up Button
Page 13 of the ProForm PFSB62830 user manual — CLEANING THE SPA SHELL
Page 13 · click to enlarge
Page 13

Maintenance

The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa.

MAINTAINING THE SPA COVER

The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.

MAINTENANCE SCHEDULE

  • Check the water level and refill the spa to the level shown in step 5 on page 9.
  • Check the pH balance and sanitizer level. Make adjustments if necessary (see WATER CHEMISTRY on page 14).

SANITIZING THE HYDROTHERAPY SPA

Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.

  • Clean the spa shell at the waterline.
  • Check and thoroughly clean the filter (see CHECKING AND CLEANING THE FILTER on this page).
  • Replace the filter if needed (see ORDERING REPLACEMENT PARTS on the back cover of this manual).

The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, water conditions, etc. Proper water maintenance is a com- plex process. We recommend that you contact your local pool and spa supplier for information about how to accomplish this.

  • Clean the spa cover (see MAINTAINING THE SPA COVER on this page).
  • Soak the filter for two hours in a trisodium phosphate (TSP) solution. Rinse the filter in clean water.
  • Replace the filter if needed (see ORDERING REPLACEMENT PARTS on the back cover of this manual).

CHECKING AND CLEANING THE FILTER

The filter should be checked periodically for build-up of dirt and oil. If the filter needs to be cleaned, follow the steps below:

1. Turn off the power. 2. Remove the filter cover. 3. Remove the basket, the diverter, the car- tridge plug, and the filter cartridge from the filter housing. 4. Check the filter car- tridge for dirt and debris. If the car- tridge needs to be cleaned, rinse it with a hose. If the car- tridge is still dirty, soak it in cleaning solution from a pool and spa supply store. 5. Inspect the filter cartridge for damage. Replace the cartridge if it is damaged. 6. Insert the cleaned or new filter cartridge into the filter housing. 7. Re-attach the filter cover.

  • Drain the spa and refill it with clean water. Sanitize and test the pH of the water.
  • Check for any leaks around the pump or joints in the pipes. The seals will wear out over time; detecting leaks early can reduce repair costs.
  • Clean the interior of the spa. Do not use solvents or waxes. (See CLEANING THE SPA SHELL below.)

MAINTAINING THE SPA EXTERIOR

The surround is maintenance-free. The surround should be cleaned with a mild soap solution; do not use solvents or waxes.

CLEANING THE SPA SHELL

The spa shell should be cleaned with a mild soap solution; do not use solvents. The spa should always be clean and dry before being moved or stored.

Show 9 more labels / short text on this page
Daily · Weekly · Monthly · Every Three Months · Filter Cover Basket · Diverter Cartridge · Plug · Filter Cartridge · Filter Housing
Page 14 of the ProForm PFSB62830 user manual — CHANGING THE FILTER CYCLE
Page 14 · click to enlarge
Page 14

WATER CHEMISTRY

ATTACHING AND REMOVING ACCESS PANEL

CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guide- lines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Do not exceed the recommended amounts of chemicals—follow the directions on the label. 4. Keep all chemicals out of the reach of children and pets. 5. Keep containers closed tightly when not in use. 6. Never add water to the chemicals—always add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place.

To locate the access panel, refer to the drawing below. Turn off the power to the spa. To remove the access panel, first remove the four #10 x 2” Sheet Metal Screws (7). Remove the Access Panel (2) by sliding it down and then pulling the bottom away from the spa. Note: Be careful not to damage the spa shell as you remove the access panel.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or alkalinity in the water. It is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa.

To re-attach the access panel (2), insert the top of the access panel under the edge of the spa shell. Slide the access panel up until the bottom of the access panel clears the trim along the bottom of the spa. Then, slide the access panel into place and re-attach the four #10 x 2” Sheet Metal Screws (7).

Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four times a year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made.

To maintain the proper pH level, you should test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supplier. The pH read- ing should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH.

The hydrotherapy spa should always be covered when it is empty. Direct sunlight can cause exten- sive damage. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty.

CHANGING THE FILTER CYCLE

The spa will filter the water every 12 hours. The dura- tion of the cycle can be adjusted to last 2 to 5 hours. Press the temp up or temp down button on the con- sole. When the display begins to flash, press the jet button. The display will read F2. To change the time, press the temp up button until the desired time is reached. Press the jet button to confirm the selection. As spa usage increases, the duration of the filter cycle may need to be increased.

Page 15 of the ProForm PFSB62830 user manual — DRAINING THE PUMP
Page 15 · click to enlarge
Page 15

To drain the hydrotherapy spa, follow the steps below:

WINTER USE AND CARE

1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the access panel from the spa (see ATTACHING AND REMOVING THE ACCESS PANEL on page 14). 4. Pull the hose out and hold it above the waterline. Remove the cap, open the valve knob, and attach a garden hose to the drain hose. Lower the hose and drain the spa.

The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winter- ize the spa.

1. Make sure the power to the spa is turned off. 2. Drain the spa (see DRAINING THE HYDROTHER- APY SPA on the previous page and this page). 3. Remove all remaining water from the spa shell. Dry the spa shell with towels. 4. Set the air controls to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each jet, starting with the highest jet and fin- ishing with the lowest jet. 5. Set the air controls to the highest setting and repeat step 3. 6. Drain the pump (see DRAINING THE PUMP on this page). Once the water is drained from the pump, place the vacuum nozzle over the drainage hole in the pump and vacuum any additional water from the pump. Note: For additional protection, remove the pump from the spa and store it in a climate-controlled room. 7. Clean the spa shell (see page 13). 8. Clean the filter (see page 13). 9. Shut the power off at the breaker. Label the breaker in such a way that the breaker will not be turned on accidentally. 10. Re-attach the access panel and the spa cover.

Drain Hose Valve Knob

5. When the spa is empty, remove the garden hose, close the valve knob, re-attach the cap, and return the drain hose inside the spa. 6. Re-attach the access panel. 7. Refill the spa and treat the water with chemicals (see pages 10 and 13).

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to remove the access panel to replace it (see ATTACHING AND REMOVING THE ACCESS PANEL on page 14). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell.

DRAINING THE PUMP

After the hydrotherapy spa is drained, the jet pump should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez- ing temperatures.

Turn off the power to the spa. To drain the jet pump, remove the access panel from the spa unit (see ATTACH- ING AND REMOVING THE ACCESS PANEL on page 14). Locate the jet pump inside the spa. Loosen the indi- cated collar on the pump.

To replace the light bulb, pull the old light bulb out of the housing and insert a new light bulb. Re-attach the light housing to the spa shell. Re-attach the access panel to the spa.

Show 6 more labels / short text on this page
Cap · Light Housing · Light · Bulb · Light Housing · Collar
Page 16 of the ProForm PFSB62830 user manual — 6. SYMPTOM: THE WATER DOES NOT HEAT
Page 16 · click to enlarge
Page 16

Troubleshooting

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time.

1. SYMPTOM: THE SPA WILL NOT OPERATE

b. If you are using the hydrotherapy spa outdoors,

it may take longer for the water to heat. See the chart below for the approximate heating time.

a. Check to see if the GFCI breaker is tripped or

was not turned on. Reset the GFCI breaker.

2. SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SPA IS OPERATING

Air Temperature Heating Time 70°F + 6 to 8 hours 50°F to 70°F 9 to 11 hours 30°F to 50°F 12 to 14 hours

a. Reset the circuit breaker or the GFCI. If the cir-

cuit breaker or the GFCI trips again, contact a qualified electrician for service.

b. If the water still has not heated after four days,

contact our customer service department.

3. SYMPTOM: THE PUMP HUMS

7. SYMPTOM: THE WATER IS NOT BEING CLEANED BY THE FILTER

a. The filter may be dirty or damaged. Remove

the filter from the filter housing and clean or replace the filter (see page 13).

a. Check to see if the filter are in place. Clean the

filter if they are dirty.

b. The pump may have a foreign object stuck in

the impeller. Contact our customer service department.

b. Check the chemical balance of the water. If the

pH is incorrect, the sanitizing agents will not function properly. See the section on maintain- ing the proper pH balance on page 13.

c. The pump may have a loose wire connection.

Contact our customer service department.

8. SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW
4. SYMPTOM: THE PUMP HUMS, BUT DOES NOT ROTATE

a. This usually occurs only when the water level is

a. The pump may be jammed. Contact our cus-

low. Add water until it is 2 to 4” above the skim- mer basket.

tomer service department. If your spa is no longer under warranty, contact a local spa and pool service provider.

b. The filter cover may not be tight. Make sure the

filter cover is tight.

5. SYMPTOM: THE PUMP IS NOISY WHILE OPERATING

9. SYMPTOM: THE WATER LEVEL DROPS

a. There may be debris in the pump. Contact our

a. A clamp or seal inside the pump compartment

customer service department.

may be loose. Check inside the pump compart- ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.

b. The pump may have a bad bearing. Contact

our customer service department.

6. SYMPTOM: THE WATER DOES NOT HEAT

a. Make sure that the hydrotherapy spa is fully

b. Some water loss due to evaporation is normal.

covered with the spa cover. The spa cover must be tight for the water to heat. Set the air control to low. The water will heat at a rate of 6°F per hour. If you are using the spa indoors and the room temperature is main- tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.

If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, the spa shell may have a leak. Contact your local pool and spa service provider for repairs.

Page 17 of the ProForm PFSB62830 user manual — Troubleshooting
Page 17 · click to enlarge
Page 17
10. SYMPTOM: THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF
12. SYMPTOM: THE CONSOLE DISPLAYS THE WORDS “COOL” OR “ICE”

a. The spa jets are controlled with the jet button. If

a. This is a normal function of the spa; no action

the button is pressed once, the spa jets will run at low speed. If the button is pressed again, the spa jets will run at high speed. If the button is pressed a third time, the jets will shut off. Note: If the actual temperature of the water in the spa is below the set temperature, or if the spa is running a filter cycle, the heater pump/motor will not shut off.

is necessary. The word “COOL” will appear in the display if the temperature of the water is more than 20°F cooler than the set temperature. If this happens, the heater will automatically activate to warm the water. The word “ICE” will appear if the temperature drops below 40°F. If this happens, the pump will automatically circu- late the water and warm the plumbing.

11. SYMPTOM: NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTERCLOCKWISE
13. SYMPTOM: THE CONSOLE DISPLAYS ONE OF THE FOLLOWING MESSAGES: “OH,” “5n1,” “5n3,” “FLO,” “Pd,” “O3,” “PH50,” “PH90,” or “ILOC”

a. If no air flows through the hydrotherapy jets when

a. If the console displays one of the messages

the air control is turned counterclockwise, simply turn the rims of the jets counterclockwise. Turning the rims clockwise will close the jets.

listed above, or if the console does not function properly, contact our customer service depart- ment.

Page 18 of the ProForm PFSB62830 user manual — Part List—Model No. PFSB62830 R0203A
Page 18 · click to enlarge
Page 18

Part List—Model No. PFSB62830 R0203A

Key No. Qty. Description Key No. Qty. Description

1 1 Thermometer Fitting 2 2 Access Panel 3 7 Face Ring 4 2 Small Rotator 5 2 Short Panel 6 2 Pivot Ring 7 32 #10 x 2” Sheet Metal Screw 8 1 Filter Cover 9 4 #10 x 1 1/2” Sheet Metal Screw 10 9 Medium Jet Housing 11 1 Spa Cover 12 7 Small Nozzle 13 2 Jet Pump/Motor O-ring 14 1 Electronics Package* 15 1 Skimmer Housing* 16 1 Filter 17 2 Collar With Screw 18 2 Suction Cover Assembly 19 9 Jet Ring 20 1 Jet Pump/Motor* 21 1 Jet Pump/Motor Power Cord 22 7 Nozzle Bushing 23 9 Medium Nozzle 24 1 Overlay 25 4 Corner Panel 26 5 Jet Housing 27 1 Drain Plug 28 1 Drain Plug O-ring 29 4 Rubber Washer 30 4 Buckle 31 8 #4 x 3/4” Screw 32 4 Flared Nozzle 33 1 Diverter Plate 34 2 Air Control Knob 35 1 Cover Ring

36 9 Nozzle Housing 37 4 Nozzle Retainer Ring 38 8 1/4” Washer 39 1 Rotator 40 1 Light Cover, Red 41 1 Light Cover, Blue 42 4 1/4” x 1 1/2” Bolt 43 1 Basket 44 1 Face Plate Assembly 45 1 Large Rotary Jet 46 4 1/4” Lock Washer 47 2 Gasket 48 1 Filter Door 49 1 Cartridge Plug 50 1 Motor Pad 51 1 Console with Overlay 52 3 Pulsating Jet 53 1 Waterfall Knob 54 1 Volcano Jet 55 1 Diverter knob # 1 Ground Wire # 2 Buckle Key # 1 User’s Manual # 1 Large Warning Sign # 1 Warning Sign # 1 Light Bulb # 1 Motor Board # 3 Pillow

* Indicates a part that is serviceable only by service technicians.

# Indicates a non-illustrated part.

Specifications are subject to change without notice.

Page 19 of the ProForm PFSB62830 user manual — Part List—Model No. PFSB62830 R0203A
Page 19 · click to enlarge
Page 19
ProForm PFSB62830 — Part List—Model No. PFSB62830 R0203A diagram (page 19)
Fig. 3 · Part List—Model No. PFSB62830 R0203A
Page 20 of the ProForm PFSB62830 user manual — Limited Warranty
Page 20 · click to enlarge
Page 20

Ordering Replacement Parts

To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling:

  • The MODEL NUMBER of the product (PFSB62830)
  • The NAME of the product (PROFORM ® SATURN hydrotherapy spa)
  • The SERIAL NUMBER of the product (see the front cover of this manual)
  • The KEY NUMBER and DESCRIPTION of the desired part(s) (see the PART LIST and EXPLODED DRAWING on pages 18 and 19)

Limited Warranty

ICON Health & Fitness, Inc. (ICON), warrants this product to be free from defects in workmanship and mate- rial, under normal use and service conditions, for a period of ninety (90) days from the date of purchase. ICON extends a limited five (5) year warranty on the spa shell structure. ICON extends a limited two (2) year war- ranty on the pump, motor, and electronics package. This warranty extends only to the original purchaser. ICON's obligation under this warranty is limited to replacing or repairing, at ICON's option, the product through one of its authorized service centers. All repairs for which warranty claims are made must be pre-authorized by ICON. This warranty does not extend to any product or damage to a product caused by or attributable to freight damage, abuse, misuse, improper or abnormal usage, or repairs not provided by ICON authorized ser- vice personnel; to products used for commercial or rental purposes; or to products used as store display mod- els. Specifically excluded are damages caused by or attributable to the following incidents: any damage to the premium cedar surround or frame attributable to improper handling or freight damage; damage resulting from improper winterization; damage to the spa shell resulting from improper chemical treatment, damage to the spa shell resulting from exposure to extreme temperatures, or damage to the spa shell resulting from expo- sure to direct sunlight and ultraviolet rays while the spa is empty; damage to the pump, motor, plumbing, and components due to improper maintenance, chemical treatment, or exposure; or damage resulting from failure to properly follow user’s manual installation, operating, or maintenance instructions. Also excluded are con- sumable components, including but not restricted to filter cartridges. No other warranty beyond that specifi- cally set forth above is authorized by ICON.

ICON is not responsible or liable for indirect, special or consequential damages arising out of or in connection with the use or performance of the product or damages with respect to any economic loss, loss of or damage to property including water damage, loss of revenues or profits, loss of enjoyment or use, costs of removal, installation or other consequential damages of whatsoever nature. Some states do not allow the exclusion or limitation of incidental or consequential damages. Accordingly, the above limitation may not apply to you.

The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of mer- chantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein. Some states do not allow limitations on how long an implied warranty lasts. Accordingly, the above limitation may not apply to you.

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813

Part No. 195185 R0203A Printed in USA © 2003 ICON Health & Fitness, Inc.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
TO14Pure water has a value of 7, which is neutral. p.14

Ask about the ProForm PFSB62830

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the ProForm PFSB62830

Be the first to ask — other owners or our team will answer.

Original document

ProForm PFSB62830 manual PDF

20 pages·635 KB·Hot Tub·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…