physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy.
29. DANGER—To reduce the risk of drowning: Prolonged immersion in the hydrotherapy spa may cause hyperthermia. The causes, symp- toms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F. The symp- toms of hyperthermia include an increase in the internal temperature of the body, dizzi- ness, lethargy, drowsiness and fainting. The effects of hyperthermia include failure to per- ceive heat; failure to recognize the need to exit the spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub and unconsciousness resulting in danger of drowning. WARNING: The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia.


Congratulations for selecting the new PROFORM®
For your benefit, read this manual carefully before using the hydrotherapy spa. If you have questions after reading the manual, please call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please mention the product model number and serial number when calling. The model number is PFSB62830. The serial number can be found on a decal on the access panel inside the spa (see the front cover of this manual).
SATURN hydrotherapy spa. The innovative SATURN spa allows you to enjoy all the benefits of hydrothera- py in the comfort and privacy of your home.
Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life. The warm environment stimulates blood flow, which is essential in the healing process, and the powerful massage action further eases tension and stress throughout the body. The PROFORM SATURN hydrotherapy spa gives you the specialized treatment you need to feel your best.
Before reading further, please familiarize yourself with the parts that are labeled in the drawing below.

There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.
If you set up the hydrotherapy spa inside:
If you set up the hydrotherapy spa outside:
10.Be sure to note any other considerations, such as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the spa.

Before beginning assembly, carefully read the following information and instructions:
ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included):
A wire connector is provided on the electronics pack of the spa to connect a minimum No. 6 AWG (13.3 mm2) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa.
Remove the four indicated #10 x 2” Sheet Metal Screws (7). Remove the indicated Access Panel (2) by sliding it down and then pulling the bottom away from the spa. Be careful not to damage the spa shell.
Locate the four gate valves inside of the spa (two are shown). Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves. In addition, make sure that the six collars are tight (four are shown).
See step 1. Re-attach the Access Panel (2) with the four #10 x 2” Sheet Metal Screws (7).

4. The spa operates on a 240 volt power source and must be wired directly to a 30 amp Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed electrician. A wiring diagram has been provided on the inside of the electronics package as a reference. Under no circumstances should the spa be wired by someone other than a qualified electrician. Before you have the spa wired, make sure that it is in the desired position and that it can be serviced, if needed.
Insert a garden hose into the filter housing, and begin filling the spa. Do not use soft water. The spa may be filled with cold water; however, if warm or hot water is used, the spa will be ready for use sooner. Fill the spa until the water is at the level of the molded fill line. Do not overfill the spa.
Refer to the inset drawing. Set the Filter (16), the Cartridge Plug (49), the Diverter Plate (33), and the Basket (43) into the filter housing. Next, screw the Filter Cover (8) into the filter housing until it is fully seated.
6. Pull down one of the straps on the Spa Cover (11) and hold the Buckle (30) against one of the cedar panels on the spa. (Note: To position the Buckle cor- rectly, have a second person hold the strap on the opposite side of the Spa Cover tight.) The Spa Cover must be tight. Do not place the Buckle over the grooves between the cedar panels. Refer to the inset drawing. Remove the latch from the Buckle. Attach the Buckle to the cedar panel with two #4 x 3/4” Screws (31).
Attach the other three Buckles (30) to the cedar pan- els in the same way.
Remove the Spa Cover (11) from the spa.

The hydrotherapy spa is designed to seat five adults. The spa holds 295 gallons of water and offers a heat- ing system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.
the jet button on the console (see USING THE CON- TROLS on page 12). Once the spa is running, press the GFCI “test” button. The spa should shut off. Press the “reset” button. The spa should resume normal operation. If the spa continues to run after the “test” button is pressed, the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.
The hydrotherapy spa is designed to operate with a 240 volt power source. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 30 amps. No other appliance should be on the same circuit. Connection of the spa to the 240 volt power source must be performed by a qualified, licensed electrician and must comply with all local, state, and federal electrical codes. The qualified, licensed electrician can refer to the instructions on the inside of the electronics package for information about con- necting the spa to a 240 volt power source.
Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONTROLS on page 12). The pumping unit will heat the water as it pumps. Cover the hydrotherapy spa with the spa cover. The spa cover must be tight (see SECURING THE SPA COVER ON THE SPA below). The water will heat at about 6°F per hour with the cover on. If you are using the spa indoors, and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.
Once the spa is filled with water, the power can be turned on. Note: The first time the power is turned on, the spa will start automatically.
The temperature and the water flow can be set or changed with the controls on the console (see USING THE CONTROLS on page 12).
SECURING THE SPA COVER ON THE SPA
The first time you use the spa, you should test and treat the water. You must also treat the water each time you refill the spa. A test strip and a chemical pack are available at your local pool and spa supplier. Follow the directions carefully on the chemical pack to test and treat the water. Always keep the chemicals away from children and pets.
To secure the spa cover, snap the latches on the spa cover into the buckles on the cedar panels.
To lock the buckles, insert the key and turn it clock- wise 1/4 turn. To unlock the buckles, insert the key and turn it counterclock- wise 1/4 turn. Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children.
See WATER CHEMISTRY on page 14 for information concerning proper water maintenance.
You should always test the GFCI before using the hydrotherapy spa. First, turn on the spa by pressing
Latch · Key · Buckle

A A
P
D
T
Q Q
K
Q
T
K
B
E
F
I J
T
G
A
H
O U N
L R S M
P
Refer to the diagram above. The function of each component is explained below.
I. The temperature probe monitors water tempera-
ture.
A. The four adjustable, directional jets can be pivot-
J. The underwater light can be used for night opera-
ed to direct their water flow. To open the jets, turn the rims counterclockwise; to close the jets, turn the rims clockwise. If no air flows through the jets, turn the jets counterclockwise. Close the jets to increase the water pressure to other jets.
tion (see USING THE CONTROLS on page 12).
K. The two suction vents near the floor of the spa
bring water into the pumps. Never operate the spa without the suction covers in place.
B. The adjustable, pulsing jet produces a soothing,
L, M. The air controls determine the air flow to the
pulsing massage action. To open the jet, turn the rim counterclockwise; to close the jet, turn the rim clockwise.
jets (see USING THE CONTROLS on page 12).
N. The filter can be removed for cleaning or replace-
ment (see CHECKING AND CLEANING THE FIL- TER on page 13).
C. The large rotary jet features two jets of water that
provide a pulsing, spinning massage action. Turn the jet counterclockwise to open it or clockwise to close it.
O. The console controls the jets, the light, and the
water temperature (see USING THE CONTROLS on page 12).
D. The two whirly jets provide a continuous, whirling
P. The three pillows can be removed or turned 180°
massage action.
to provide two positions of comfort.
E. The six small adjustable, directional jets can be
Q. The nine medium directional jets pinpoint the
pivoted to direct their water flow. Turn the rims of the jets to open and close them.
lower, middle, and upper sections of your back.
R. The waterfall valve adjusts the waterfall flow.
F. The volcano jet provides a powerful foot massage.
S. The waterfall creates a soothing sound and mas-
G. An optional ozone generator can be purchased and
sage.
installed to utilize the ozone jet. Ozone provides a way to help sanitize the spa with minimal chemical treatment.
T. The three adjustable twin-nozzle jets produce a
pulsating hydrotherapy action.
H. The skimmer cleans the surface of the water.
U. The diverter knob directs the water flow (see
USING THE CONTROLS on page 12).

Temperature Down Button Temperature
Refer to the diagram above. The function of each control is explained below:
the jets labeled M. Air control L controls air flow to the jets labeled L. If a control is turned counterclockwise, the amount of air flowing through the jets will increase. If the control is turned clockwise, the amount of air will decrease.
Jet Button: Turns the spa jets on and off. If the but- ton is pressed once, the spa jets will run at low speed, providing gentle hydrotherapy. If the button is pressed again, the jets will run at high speed, providing more intense hydrotherapy. If the button is pressed a third time, the jets will shut off.
Waterfall Knob: Controls the flow of water through the waterfall.
Diverter Knob: Diverts the water flow two ways. If the knob is turned clockwise, water is diverted to the seats labeled 1, 2, and 4 below. If the knob is turned counterclockwise, water is diverted to the seats labeled 3 and 5 below and the volcano jet (see F on the SPA SHELL DIAGRAM on page 11). Note: The diverter knob may be difficult to turn while the pump is running at high speed.
The spa also features an automatic mode that heats and filters the water when the spa is left unattended. When the power to the spa is first turned on, or if the water temperature is below the set temperature, the water will be heated as required to maintain the set temperature. Note: To keep the filter and heat cycles from running, the power to the spa must be turned off.
Light Button: Turns the underwater light on and off.
Temperature Buttons: Control the temperature setting of the water. The temperature can be set between 80°F and 104°F. The water heats at about 6°F per hour with the cover on. Use a medical or other accu- rate thermometer to check the temperature of the water. Note: The word “COOL” will appear in the con- sole display if the temperature of the water is more than 20°F cooler than the set temperature. When this happens, the heater will automatically activate to warm the water. The word “ICE” will appear in the display if the temperature drops below 40°F. If this happens, the pump will automatically circulate the water and warm the plumbing to keep the water from freezing.
M
Air Controls: Determine the amount of air flowing through the spa jets during operation. Refer to the diagram at the right. Air control M controls air flow to

The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa.
The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.
Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.
The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, water conditions, etc. Proper water maintenance is a com- plex process. We recommend that you contact your local pool and spa supplier for information about how to accomplish this.
The filter should be checked periodically for build-up of dirt and oil. If the filter needs to be cleaned, follow the steps below:
1. Turn off the power. 2. Remove the filter cover. 3. Remove the basket, the diverter, the car- tridge plug, and the filter cartridge from the filter housing. 4. Check the filter car- tridge for dirt and debris. If the car- tridge needs to be cleaned, rinse it with a hose. If the car- tridge is still dirty, soak it in cleaning solution from a pool and spa supply store. 5. Inspect the filter cartridge for damage. Replace the cartridge if it is damaged. 6. Insert the cleaned or new filter cartridge into the filter housing. 7. Re-attach the filter cover.
The surround is maintenance-free. The surround should be cleaned with a mild soap solution; do not use solvents or waxes.
The spa shell should be cleaned with a mild soap solution; do not use solvents. The spa should always be clean and dry before being moved or stored.

ATTACHING AND REMOVING ACCESS PANEL
CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guide- lines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Do not exceed the recommended amounts of chemicals—follow the directions on the label. 4. Keep all chemicals out of the reach of children and pets. 5. Keep containers closed tightly when not in use. 6. Never add water to the chemicals—always add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place.
To locate the access panel, refer to the drawing below. Turn off the power to the spa. To remove the access panel, first remove the four #10 x 2” Sheet Metal Screws (7). Remove the Access Panel (2) by sliding it down and then pulling the bottom away from the spa. Note: Be careful not to damage the spa shell as you remove the access panel.
The pH factor is a measure of the relative acidity or alkalinity in the water. It is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa.
To re-attach the access panel (2), insert the top of the access panel under the edge of the spa shell. Slide the access panel up until the bottom of the access panel clears the trim along the bottom of the spa. Then, slide the access panel into place and re-attach the four #10 x 2” Sheet Metal Screws (7).
Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.
The hydrotherapy spa should be drained at least four times a year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made.
To maintain the proper pH level, you should test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supplier. The pH read- ing should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH.
The hydrotherapy spa should always be covered when it is empty. Direct sunlight can cause exten- sive damage. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty.
The spa will filter the water every 12 hours. The dura- tion of the cycle can be adjusted to last 2 to 5 hours. Press the temp up or temp down button on the con- sole. When the display begins to flash, press the jet button. The display will read F2. To change the time, press the temp up button until the desired time is reached. Press the jet button to confirm the selection. As spa usage increases, the duration of the filter cycle may need to be increased.

To drain the hydrotherapy spa, follow the steps below:
The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winter- ize the spa.
1. Make sure the power to the spa is turned off. 2. Drain the spa (see DRAINING THE HYDROTHER- APY SPA on the previous page and this page). 3. Remove all remaining water from the spa shell. Dry the spa shell with towels. 4. Set the air controls to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each jet, starting with the highest jet and fin- ishing with the lowest jet. 5. Set the air controls to the highest setting and repeat step 3. 6. Drain the pump (see DRAINING THE PUMP on this page). Once the water is drained from the pump, place the vacuum nozzle over the drainage hole in the pump and vacuum any additional water from the pump. Note: For additional protection, remove the pump from the spa and store it in a climate-controlled room. 7. Clean the spa shell (see page 13). 8. Clean the filter (see page 13). 9. Shut the power off at the breaker. Label the breaker in such a way that the breaker will not be turned on accidentally. 10. Re-attach the access panel and the spa cover.
Drain Hose Valve Knob
If the underwater light burns out, you will need to remove the access panel to replace it (see ATTACHING AND REMOVING THE ACCESS PANEL on page 14). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell.
After the hydrotherapy spa is drained, the jet pump should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez- ing temperatures.
Turn off the power to the spa. To drain the jet pump, remove the access panel from the spa unit (see ATTACH- ING AND REMOVING THE ACCESS PANEL on page 14). Locate the jet pump inside the spa. Loosen the indi- cated collar on the pump.
To replace the light bulb, pull the old light bulb out of the housing and insert a new light bulb. Re-attach the light housing to the spa shell. Re-attach the access panel to the spa.

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time.
b. If you are using the hydrotherapy spa outdoors,
it may take longer for the water to heat. See the chart below for the approximate heating time.
a. Check to see if the GFCI breaker is tripped or
was not turned on. Reset the GFCI breaker.
Air Temperature Heating Time 70°F + 6 to 8 hours 50°F to 70°F 9 to 11 hours 30°F to 50°F 12 to 14 hours
a. Reset the circuit breaker or the GFCI. If the cir-
cuit breaker or the GFCI trips again, contact a qualified electrician for service.
b. If the water still has not heated after four days,
contact our customer service department.
a. The filter may be dirty or damaged. Remove
the filter from the filter housing and clean or replace the filter (see page 13).
a. Check to see if the filter are in place. Clean the
filter if they are dirty.
b. The pump may have a foreign object stuck in
the impeller. Contact our customer service department.
b. Check the chemical balance of the water. If the
pH is incorrect, the sanitizing agents will not function properly. See the section on maintain- ing the proper pH balance on page 13.
c. The pump may have a loose wire connection.
Contact our customer service department.
a. This usually occurs only when the water level is
a. The pump may be jammed. Contact our cus-
low. Add water until it is 2 to 4” above the skim- mer basket.
tomer service department. If your spa is no longer under warranty, contact a local spa and pool service provider.
b. The filter cover may not be tight. Make sure the
filter cover is tight.
9. SYMPTOM: THE WATER LEVEL DROPS
a. There may be debris in the pump. Contact our
a. A clamp or seal inside the pump compartment
customer service department.
may be loose. Check inside the pump compart- ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.
b. The pump may have a bad bearing. Contact
our customer service department.
a. Make sure that the hydrotherapy spa is fully
b. Some water loss due to evaporation is normal.
covered with the spa cover. The spa cover must be tight for the water to heat. Set the air control to low. The water will heat at a rate of 6°F per hour. If you are using the spa indoors and the room temperature is main- tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.
If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, the spa shell may have a leak. Contact your local pool and spa service provider for repairs.

a. The spa jets are controlled with the jet button. If
a. This is a normal function of the spa; no action
the button is pressed once, the spa jets will run at low speed. If the button is pressed again, the spa jets will run at high speed. If the button is pressed a third time, the jets will shut off. Note: If the actual temperature of the water in the spa is below the set temperature, or if the spa is running a filter cycle, the heater pump/motor will not shut off.
is necessary. The word “COOL” will appear in the display if the temperature of the water is more than 20°F cooler than the set temperature. If this happens, the heater will automatically activate to warm the water. The word “ICE” will appear if the temperature drops below 40°F. If this happens, the pump will automatically circu- late the water and warm the plumbing.
a. If no air flows through the hydrotherapy jets when
a. If the console displays one of the messages
the air control is turned counterclockwise, simply turn the rims of the jets counterclockwise. Turning the rims clockwise will close the jets.
listed above, or if the console does not function properly, contact our customer service depart- ment.

Key No. Qty. Description Key No. Qty. Description
1 1 Thermometer Fitting 2 2 Access Panel 3 7 Face Ring 4 2 Small Rotator 5 2 Short Panel 6 2 Pivot Ring 7 32 #10 x 2” Sheet Metal Screw 8 1 Filter Cover 9 4 #10 x 1 1/2” Sheet Metal Screw 10 9 Medium Jet Housing 11 1 Spa Cover 12 7 Small Nozzle 13 2 Jet Pump/Motor O-ring 14 1 Electronics Package* 15 1 Skimmer Housing* 16 1 Filter 17 2 Collar With Screw 18 2 Suction Cover Assembly 19 9 Jet Ring 20 1 Jet Pump/Motor* 21 1 Jet Pump/Motor Power Cord 22 7 Nozzle Bushing 23 9 Medium Nozzle 24 1 Overlay 25 4 Corner Panel 26 5 Jet Housing 27 1 Drain Plug 28 1 Drain Plug O-ring 29 4 Rubber Washer 30 4 Buckle 31 8 #4 x 3/4” Screw 32 4 Flared Nozzle 33 1 Diverter Plate 34 2 Air Control Knob 35 1 Cover Ring
36 9 Nozzle Housing 37 4 Nozzle Retainer Ring 38 8 1/4” Washer 39 1 Rotator 40 1 Light Cover, Red 41 1 Light Cover, Blue 42 4 1/4” x 1 1/2” Bolt 43 1 Basket 44 1 Face Plate Assembly 45 1 Large Rotary Jet 46 4 1/4” Lock Washer 47 2 Gasket 48 1 Filter Door 49 1 Cartridge Plug 50 1 Motor Pad 51 1 Console with Overlay 52 3 Pulsating Jet 53 1 Waterfall Knob 54 1 Volcano Jet 55 1 Diverter knob # 1 Ground Wire # 2 Buckle Key # 1 User’s Manual # 1 Large Warning Sign # 1 Warning Sign # 1 Light Bulb # 1 Motor Board # 3 Pillow
* Indicates a part that is serviceable only by service technicians.
# Indicates a non-illustrated part.
Specifications are subject to change without notice.



To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling:
ICON Health & Fitness, Inc. (ICON), warrants this product to be free from defects in workmanship and mate- rial, under normal use and service conditions, for a period of ninety (90) days from the date of purchase. ICON extends a limited five (5) year warranty on the spa shell structure. ICON extends a limited two (2) year war- ranty on the pump, motor, and electronics package. This warranty extends only to the original purchaser. ICON's obligation under this warranty is limited to replacing or repairing, at ICON's option, the product through one of its authorized service centers. All repairs for which warranty claims are made must be pre-authorized by ICON. This warranty does not extend to any product or damage to a product caused by or attributable to freight damage, abuse, misuse, improper or abnormal usage, or repairs not provided by ICON authorized ser- vice personnel; to products used for commercial or rental purposes; or to products used as store display mod- els. Specifically excluded are damages caused by or attributable to the following incidents: any damage to the premium cedar surround or frame attributable to improper handling or freight damage; damage resulting from improper winterization; damage to the spa shell resulting from improper chemical treatment, damage to the spa shell resulting from exposure to extreme temperatures, or damage to the spa shell resulting from expo- sure to direct sunlight and ultraviolet rays while the spa is empty; damage to the pump, motor, plumbing, and components due to improper maintenance, chemical treatment, or exposure; or damage resulting from failure to properly follow user’s manual installation, operating, or maintenance instructions. Also excluded are con- sumable components, including but not restricted to filter cartridges. No other warranty beyond that specifi- cally set forth above is authorized by ICON.
ICON is not responsible or liable for indirect, special or consequential damages arising out of or in connection with the use or performance of the product or damages with respect to any economic loss, loss of or damage to property including water damage, loss of revenues or profits, loss of enjoyment or use, costs of removal, installation or other consequential damages of whatsoever nature. Some states do not allow the exclusion or limitation of incidental or consequential damages. Accordingly, the above limitation may not apply to you.
The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of mer- chantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein. Some states do not allow limitations on how long an implied warranty lasts. Accordingly, the above limitation may not apply to you.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813
Part No. 195185 R0203A Printed in USA © 2003 ICON Health & Fitness, Inc.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| TO14 | Pure water has a value of 7, which is neutral. | p.14 |