SL5000e and T5000e SR Smart Label RFID Thermal Printers RFID Labeling Reference Manual

Printronix makes no representations or warranties of any kind regarding this material, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. Printronix shall not be held responsible for errors contained herein or any omissions from this material or for any damages, whether direct, indirect, incidental or consequential, in connection with the furnishing, distribution, performance or use of this material. The information in this manual is subject to change without notice.
This document contains proprietary information protected by copyright. No part of this document may be reproduced, copied, translated or incorporated in any other material in any form or by any means, whether manual, graphic, electronic, mechanical or otherwise, without the prior written consent of Printronix.
COPYRIGHT © 2004 PRINTRONIX, INC. All rights reserved.
Alien and Alien Technology are registered trademarks of Alien Technology Corporation.
Manhattan Associates is a registered trademark of Manhattan Associates, Inc.
Matrics is a registered trademark of Matrics, Inc.
Printronix, PGL, and PrintNet are registered trademarks of Printronix, Inc.
Rafsec is a registered trademark of Rafsec.
SL5000e and T5000e are trademarks of Printronix, Inc.
Uniform Code Council, Inc. is a registered trademark of Uniform Code Council, Inc.
Zebra and ZPL are trademarks of Zebra Technologies Corporation.
Trademark Acknowledgements


Overview
Services & Support page at www.printronix.com
This manual covers the following products:

The Printronix SL5000e DK Smart Label Developer’s Kit contains: • SL5000e MP multiprotocol RFID printer
The intent of the kit is to provide a complete environment for the printing and encoding of RFID smart labels right out of the box. Printronix has specifically designed this kit to help you fast track your RFID printer application through the use of a suite of Software Migration Tools (SMT).

Factors Affecting Smart Label Performance
Smart labels are based on an EEPROM technology that requires some time to be programmed. You may notice this minor pause between labels. This time is necessary to better ensure consistent quality and improved reliability.
When dealing with smart labels, it is possible that an occasional RFID tag may need to be written and verified more than once (retry) before being considered acceptable. In this event each retry time will be added to the inter-label pause.
Static electricity can damage the smart labels. Open the media cover of the printer and touch an unpainted metal part of the printer before you handle smart labels. This will discharge any static electricity that may have built up on your hands.
If an RFID tag within a smart label is deemed unacceptable after execution of the defined number of retries, what occurs next depends upon the Error Handling setting. See “Error Handling” on page 18.

Smart Label Characteristics
For a list of currently supported tag types, download the certified smart labels brochure available at www.printronix.com
Currently supported smart labels have the following characteristics:
4 x 2, 4 x 4, 4 x 6, 4 x 8 inch label stock

How Printronix Makes It Easy
It is likely that your software is already set up to create bar codes. You may have also spent a lot of time creating compliance label templates & integrating them into your system. The Smart Label Developer’s Kit Software Migration Tools will allow you to effortlessly transition from printing compliance labels to smart labels.
If you are printing bar codes now, you can print smart labels — no change to your host data stream or existing compliance templates is required.

The existing toolset will meet the needs of many RFID early adopters. If you have a requirement for a Software Migration Tool not included in this kit, feel free to contact Printronix.
To select and use the tools, see “Software Migration Tools (SMT)” on page 44.
To order more RFID smart labels, contact Printronix: (800) 733-1900 www.printronix.com
Printronix can partner with you on your RFID pilot project to make your existing software applications RFID/smart label capable. We specialize in smart label print and apply configuration and integration, RFID pilot implementation, and transition from RFID pilots to full production rollouts.
Printronix Customer Support Center (714) 368-2686 Ask for Professional Services Support

Once your smart labels have been applied to their target container or pallet you will need external readers to track them through your supply chain. Such readers are typically networked devices that are deployed at key points in the warehouse or distribution center to track incoming and outgoing packages. The readers are managed through a server for gathering and filtering all the RFID information. Readers may have multiple antennas to maximize read range and reliability.
The readers you purchase must be compatible with the smart labels programmed by the printer. Specifically, they should be EPC Class 0, Class 0+, Class 1, and Class 1.19 compliant. Fixed position readers and their antennas can be purchased from companies such as Alien Technology® (www.alientechnology.com). Handheld readers with integrated antennas can be purchased from AWID (www.awid.com).
The data that are gathered by the reader servers must be managed for tracking and archiving purposes. Software applications that perform these tasks are available from companies such as Manhattan Associates® (www.manh.com).
Contact Information

Useful Industry Web Links
Reference Material
Printronix, Inc. www.printronix.com
Alien Technology Corporation www.alientechnology.com
Applied Wireless Identifications Group, Inc. www.awid.com
Auto-ID Labs www.autoidlabs.org
EPC Tag Data Translation www.autoidlabs.org/cambridge/TDS
EPCglobal, Inc. www.epcglobalinc.org
RFID Journal www.rfidjournal.com
Uniform Code Council, Inc.®

Overview
This chapter describes how to use the RFID encoder. The RFID encoder is designed to be transparent to the printer operation. It provides the capability of programming smart labels (with embedded RFID tags) while printing the label format. The smart labels are provided with the printer or purchased separately from Printronix.
There are several ways to program RFID tags in smart labels:



Alien Squig 64* Tag Type Alien Squig 96 Alien M-TAG 64 Alien M-TAG 96
RAF Omni 313 64 RAF Omni 342 96 Matrics1020 64
Italicized items appear only when Admin User is set to Enable (in the PRINTER CONTROL menu).
2 Appears only if Tag Type is set to Matrics2020 64 or Matrics2020 96.
(cont. on next page)


Custom Tag Class Class 1* Class 0 Class 0+ Class 1.19
Italicized items appear only when Admin User is set to Enable (in the PRINTER CONTROL menu).

RFID CONTROL Menu Items
RFID Reader
This menu item enables or disables the RFID encoder. The default is Enable.
This menu item selects the error handling mode for RFID failures. The default is Overstrike.
In Overstrike mode, each failed label prints with the Overstrike pattern and the form retries on a new label until the Label Retry count is exhausted. Whether or not an error message will display or the failed label will reprint depends upon the Max Retry Error setting.
In None mode, no specific action is taken when a tag fails to be programmed.
In Stop mode, when a tag fails to be programmed, the printer will halt and display the error message “RFID Error: Check Media.” The label is discarded and reprinting of the label (if desired) must be initiated from the host. When the error is cleared, the label with the failed tag moves forward until the next label is in position to be printed.
set to Overstrike.
This menu item selects the number of label retries that the RFID encoder will attempt before declaring a fault. This may indicate a problem with the RFID encoder, the antenna assembly, the printer setup, or the label stock. The default is 10.
This menu item enables or disables the Max Retry Error menu item. If it is set to Disable, errors are not declared and the print content for the current label is discarded. The default is Enable.

RFID CONTROL Menu Items
This menu item displays on the control panel’s LCD the number of tags written since the last Clear Tag Stat operation has been initiated. (See “Clear Tag Stat” below.)
This menu item displays on the control panel’s LCD the number of failed tag write attempts since the last Clear Tag Stat operation has been initiated. (See “Clear Tag Stat” below.)
This menu item clears the Tag Write Cnt and Failed Tag Cnt menu items.
This menu item displays on the control panel’s LCD the reader firmware version.
When this menu item is set to Enable, the RFID encoder checks the tags for a pre-programmed quality code. If the code is absent, the tag immediately fails and the selected Error Handling mode is performed (Overstrike, None, or Stop). The default is Disable.
This menu item selects the style of the overstrike pattern. The default is Grid.
When it is set to Grid, a grid pattern prints when it overstrikes. When it is set to Error Type Msg, an error message prints that indicates which error occurred (see Table 1).

Table 1. Printed Overstrike Error Messages
Tag R/W Err x Check media
The printer software attempted to write to or read from the RFID tag, but the RFID encoder indicated that the tag could not be written to or read from.
Tag Comm Err x Check cable
The printer software temporarily lost communication with the RFID encoder, or communication between the printer software and the RFID encoder was not synchronized and had to be forced.
Precheck Fail x Check media
This failure occurs only when the Precheck Tags menu item is set to Enable. It indicates that the RFID tag was automatically failed since it did not contain the correct pre-programmed quality code.
identifies the area in the printer software or RFID encoder where the failure occurred.
Error Message Explanation

Admin User Menu Items
To see these menu items, set Admin User to Enable in the PRINTER CONTROL menu. (Refer to the User’s Manual.)
This menu item selects the tag type in use. The following is a list of tag types available. Other types may be added in the future. • Alien Squig 64 (default) Class 1, read/write, 66 bit, general purpose 4 inches wide

RFID Test (This Test Reads A Tag)
This menu item reads the tag in range of the internal RFID antenna and reports the tag data to the debug port and momentarily displays it on the control panel’s LCD. It is primarily intended for development verification by checking that the system is working.
Normally, virgin Class 0+ tags are delivered pre-erased, allowing the printer to encode them directly. If an error occurs during the initial encoding the ensuing retries will include an automatic erase. If the tags are used and are known to have been previously written to then an erase cycle will be necessary.
By enabling the PreErase Class 0+ option an erase cycle will be forced on the first try. This is applicable when doing loop tests in the lab.
This menu item selects the number of automatic (internal) retries that the RFID encoder will attempt on the same tag before declaring a tag error and performing the Error Handling mode selected (Overstrike, Stop, or None). The default is 2.
This menu item enables or disables the Custom Pwr Set, Custom Tag Len, and Custom Tag Class menu items (custom tag menus). The default is Disable.
The custom tag menus allow the RFID encoder to work with tag types that are not listed in the Tag Type menu item.
not certified by Printronix.
When Custom Tag is set to Disable, the settings in the custom tag menus are ignored by the RFID encoder.

Admin User Menu Items
When it is set to Enable, the RFID encoder uses the settings in the custom tag menus, which must be set to match the characteristics of the custom tag.
When it is set to Duplicate, the settings of the selected Tag Type menu item are copied into the custom tag menus.
This menu item selects the power level to be used in the RFID encoder. 1 is the lowest power level setting, and 20 is the highest. The default is 5.
This menu item selects the number of bytes in the tag. The default is 8.
This menu item selects the class of the custom tag. Class 1, Class 0+, and Class 1.19 tags are read/write. Class 0 tags are read only. The default is Class 1.
This menu item enables the use of print and apply hardware. The default is Disable.
This menu item enables EPC and label information to be sent out the network port. This information can be used by an RFID tag data and labels manager program. The default is Disable.

RFID PGL Commands
Purpose The RFWTAG command is used to program an RFID tag (embedded in a smart label) using structured data format. The data structure of an RFID tag can consist of one or more bit fields. Each bit field specifies its own field length, the data format, the field type plus additional options if the type is incremental, and finally the field value.
Format RFWTAG;[LOCKn;]size (Bit Field)+ STOP
RFWTAG Specifies the RFWTAG command, enter RFWTAG;
LOCKn Optional parameter specifies that the data should be protected from being overwritten later. By default the data are not protected. The acceptable values for n are 1 to 255, meaning the data are to be protected using this byte as the LOCK password.
size A decimal number specifying the overall bit length of the RFID tag.
Bit Field A line description of a bit field and must have one of the following syntax formats:
Mode CREATE

length A decimal number specifying the bit length of a field within a tag. The maximum length for each DFn field is 64 bits.
DFn Optional parameter to indicate this field has dynamic data. Replace n with a number ranging from 1 to 512 to identify the field number of this particular field. If this option is used, datafield is ignored, and dynamic data must be entered via the DF command in the EXECUTE mode.
IDFn Enter IDF to indicate this field is a bit field with dynamical assignment of increment (or decrement) data. The step and startdata parameters will be supplied by the IDF command in the EXECUTE mode. Replace n with a number ranging from 1 to 512 to identify the field number of this bit field. Dynamically enter the step and startdata parameters using the IDF command in the EXECUTE mode.
IDFn.
format A letter specifying the format of the data field. B – binary, D – decimal, H – hexadecimal
(D) Delimiter designating the start and end of static data for this bit field. Replace (D) with any printable character, except the SFCC and the slash character (/).

datafield The static data of this static field. It is a mandatory parameter of bit field with static data.
I Identifies this field is an incremental bit field.
STEP Specifies that the incremental data field will use the step method. Enter STEP;. The STEP option replaces the STEPMASK option that is used in Alpha and Barcode.
idir Enter a plus sign (+) or leave the field blank to increment (default). Enter a minus sign (–) to decrement.
step A decimal number specifies the amount to increment/ decrement each time the form is executed. The increment is at bit level and will automatically wrap based on the field size.
RPTn The optional incremental repeat count parameters to specify the number of times a particular field value is repeated before it is incremented. The default repeat count parameter n is 1, which will increment the field value each time it prints. The repeat count can range from 1 to 65535.
RSTn The optional incremental reset count parameter to specify the number of times an incremented field is printed before it is reset to the starting value. By default, there is no reset count. The reset count parameter n can range from 1 to 65535.
value Defines the value of the field or the starting value of the incremented field. If the field is dynamic, the value will be specified later in the EXECUTE mode. The data must be specified within a pair of delimiters (D). The delimiter (D) cannot be a “/” or SFCC character since the “/” will comment out the rest of the line and SFCC is reserved for PGL commands. If “R” or “S” is used as delimiters, the data pattern must not comprise of the keywords in the incrementing options. Since the delimiters could be different from one value to another, proper care must be taken to avoid one of the letters mentioned above.

per form.
The following example programs an SGTIN–64 value into the RFID tag that is embedded in a 4x6 smart label. Assume that the SGTIN–64 value is provided as a single number.
~CREATE;SGTIN–64;432 RFWTAG;64 64;H;*87D0034567ABCDEF* /EPC number STOP END ~EXECUTE;SGTIN–64;1 ~NORMAL
Example 1

Same as Example 1, except the EPC number is broken into its component parts. Assume that the SGTIN–64 value has the Header = 2d, Filter Value = 5d, EPC Manager Index = 15383d, Object Class = 703710d or 0xABCDE, and the Serial Number = 0123456d.
~CREATE;SGTIN–64;432 RFWTAG;64 2;B;*10* /Header 3;D;*5* /Filter Value 14;D;*15383* /EPC Manager Index 20;H;*ABCDE* /Object Class 25;D;*0000123456* /Serial Number STOP END ~EXECUTE;SGTIN–64;1 ~NORMAL
Same as Example 2, except it uses a dynamic method. This example also shows how to program another RFID tag without redefining the data structure of the SGTIN–64.
~CREATE;SGTIN–64;432 RFWTAG;64 2;DF1;B /Header 3;DF2;D /Filter Value 14;DF3;D /EPC Manager Index 20;DF4;H /Object Class 25;DF1;D /Serial Number STOP ALPHA AF1;18;10;5;3;3 STOP END ~EXECUTE;SGTIN–64 ~DF1;*10* /Header ~DF2;*5* /Filter Value ~DF3;*15383* /EPC Manager Index ~DF4;*ABCDE* /Object Class ~DF5;*0000123456* /Serial Number
Example 2 · Example 3

~AF1; /Print serial number on label ~NORMAL
~EXECUTE;SGTIN–64 ~DF1;*10* /Header ~DF2;*5* /Filter Value ~DF3;*15383* /EPC Manager Index ~DF4;*ABCDE* /Object Class ~DF5;*0000123456* /Serial Number ~AF1; /Print serial number on label ~NORMAL
This example shows how to program a roll of 1500 smart labels with SGTIN–64 values, where the Header = 2d, Filter Value = 5d, EPC Manager Index = 15383d, Object Class = 703710d or 0xABCDE, and the Serial Number starting from 0000000 to 0001499d.
~CREATE;SGTIN–64;432 RFWTAG;64 2;B;*10* /Header 3;D;*5* /Filter Value 14;D;*15383* /EPC Manager Index 20;H;*ABCDE* /Object Class 25;I;D;STEP1;*0* /Serial Number STOP END ~EXECUTE;SGTIN–64;ICNT1500 ~NORMAL
This example shows how to program a 96 bit RFID tag. A SGTIN–96 format is used and the EPC number is broken into its component parts. Assume that the SGTIN–96 value has the Header = 2d, Filter Value = 5d, EPC Manager Index = 15383d, Object Class = 703710d or 0xABCDE, and the Serial Number = 0123456d.
and no field can be more than 64 bits in length.
Example 4 · Example 5

~CREATE;SGTIN–96;432 RFWTAG;96 8;B;*00110000* /Header 3;D;*5* /Filter Value 3;D;*6* /Partition 20;D;*123456* /Company Prefix 24;D;*7777777* /Item Reference 38;D;*123456* /Serial Number STOP END ~EXECUTE;SGTIN–96;1 ~NORMAL
Purpose To read the content of an RFID tag (embedded in a smart label) into a dynamic field. This command cannot be mixed with the RFREAD command.
Format RFRTAG;size (Bit Field)+ STOP
RFRTAG Specifies the RFRTAG command, enter RFRTAG;
size A decimal number specifying the overall bit length of the RFID tag.
Bit Field A line description of a bit field; must have one of the following syntax formats: length;DFn;format
length A decimal number specifying the bit length of a field within a tag. The maximum length is 64 bits.
DFn Indicate dynamic data field to store the read result. Replace n with a number ranging from 1 to
Mode CREATE

512 to identify the field number of this particular field.
format A letter specifying the representation format of the field data. B – binary, D – decimal, H – hexadecimal
form but the same DFn field cannot be defined multiple times. 2. The DF field length is restricted to 64 bits and must be a multiple of 8 bits. The sum of all field lengths must be equal to the tag size. 3. The first field always start at the MSB bit. The bit length of a field dictates the start bit of the next field, etc. As a result, DF fields will not overlap each other. 4. RFRTAG does not allow incremental fields (with the “I” prefix).
Same as Example 4 on page 29, except the increment is dynamic and the result is merged into Alpha to print on the smart label.
~CREATE;SGTIN–64;432 RFWTAG;64 2;B;*10* /Header 3;D;*5* /Filter Value 14;D;*15383* /EPC Manager Index 20;D;*123456* /Object Class 25;IDF1;H /Serial Number STOP RFTAG;64 64;DF2;H; STOP ALPHA IAF1;16;3;12;0;0 STOP
Example

END ~EXECUTE;SGTIN–64;ICNT1500 ~IDF1;STEP+1;*0* ~IAF1;<DF2>
~NORMAL
merges the DF1 content into the AF1 field, keeping the same representation previously defined for IDF1.
Purpose Request the printer to send to the host the ASCII representation of a dynamic field. The dynamic field could be one of AFn, BFn, or DFn, but cannot be RFn.
Format VERIFY;field;format;(D)ASCIIheader(D)
VERIFY The command to verify data of a dynamic field, enter VERIFY;
field The dynamic field AFn, BFn, or DFn that contains the data to be sent to the host.
format A letter specifying the format of the outgoing data to be sent to the host. B – binary, D – decimal, H – hexadecimal, S – string
Based on the incoming format of the data field, a format conversion may be performed if the outgoing format is not the same. The AFn and BFn format is always S type. The DFn format could be either B, D, or H. Due to the possible conversion the outgoing data stream could be longer than the incoming one.
Mode CREATE

The maximum length for the outgoing data is 512 bytes. If the format request will result in a data stream exceeding the maximum length, an error would be reported.
A mandatory parameter to specify an ASCII string of characters, which is followed by the RFID data, to be sent by the printer to the host.
(D) Delimiter designating the start and end of a character string. Replace (D) with any printable character, except the SFCC and the slash character (/). The string could be empty, i.e. there are not headers preceeding the field data.
mode before it can be specified in the VERIFY command otherwise it will be considered as a syntax error and the VERIFY command will abort. 2. All RFID Read/Write commands are executed first in the order they appear in CREATE mode, followed by Alpha and Barcode commands, and finally VERIFY commands. The VERIFY commands are always executed last although they may appear before other commands in the CREATE mode. The reason for this is to make sure the data are sent back to the host only if other commands are completed and the form is not aborted. 3. If the data comes from a DFn field, the DFn format is the original format before any conversion. If the VERIFY command specifies a different format, the data would then be converted to the new format. If the data comes from an AFn or BFn, the original format is S format.
ASCIIheader

This example requests the printer to send to the host the content of the RFID tag, in hexadecimal format, both before and after the RFWTAG command writes data to the tag. Also, the label is not moved.
~CREATE;VERIFY;432;NOMOTION RFRTAG;64 64;DF1;H STOP VERIFY;DF1;H;*TagBefore=* RFWTAG; 64 2;B;*01* 6;D;*29* 24;H;*466958* 17;H;*ABC* 15;D;*1234* STOP RFRTAG;64 64;DF2;H STOP VERIFY;DF2;H;*TagAfter=* END ~EXECUTE;VERIFY;1 ~NORMAL
TagBefore=A5A500005D055E04
This example reads a roll of 1500 pre-programmed smart labels.
Example 1 · Example 2

~EXECUTE;READONLY;1500 ~NORMAL
A5A500005D055E04
This example requests the printer to program a roll of 2000 smart labels using the RFWTAG command with incremental field. Then, it sends the actual data from each of the 2000 tags to the host.
~CREATE;SIMPLE;432;NOMOTION RFWTAG;64 2;B;*01* 6;D;*29* 24;H;*466958* 17;H;*ABC* 15;I;D;STEP+1;*0000* STOP RFRTAG; 64 64;DF1;H STOP VERIFY;DF1;H;*Data=* END ~EXECUTE;SIMPLE;ICNT2000 ~NORMAL
Data=5D466958055E0000
Example 3

Write Tag
Purpose To program non-incremental data into an RFID tag (embedded in a smart label).
RFWRITE; The RFID Write Tag command.
HEX; Optional parameter to indicate that the text in datafield is in hexadecimal format and that it will be converted to binary format.
EPCm; Optional parameter to indicate that the data in datafield should be converted to an EPC number. When this parameter is used, the HEX option is automatically enabled and the data field is limited to a maximum of 14 digits. The AT parameter is ignored. The tag is then programmed as follows:
Bits 0 to 1 are programmed with the EPC value 0 to 3, specified in m.
Bits 2 to 57 are programmed with the hexadecimal characters in the data field (14 maximum). If the data field has less than 14 hexadecimal characters, zeros are assumed for the remaining digits.
Bits 58 to 63 are set to zero.
RFn;L; Optional parameter to indicate that this field has dynamic data. Replace n with a number ranging from 1 to 512 to identify the field number of this RFWRITE field. Replace L with the length of the dynamic
Mode CREATE · Format · RFWRITE;[HEX;][EPCm;][RFn;L;][LOCK;]ATp;[(D)datafield(D)]

data string. If this option is used, the datafield is ignored, and dynamic data must be entered via the RF command in the EXECUTE mode. The length of the dynamic data must be equal to L.
LOCK; Optional parameter to write-protect the data. Currently not supported.
ATp; p specifies the decimal start position where data will be written to the tag. Subsequent bits will be shifted and previous bits are nulled.
(D) Delimiter designating the start and end of static data for the RFWRITE field. Replace (D) with any printable character, except the SFCC and “/” (the slash character).
datafield The static data of the RFWRITE field.
HDUP sections.
Write Tag

Read Tag
Read Tag is not a command, but an element of the ALPHA and BARCODE commands. See “Alphanumerics” and “Bar Codes” in the IGP/PGL Programmer’s Reference Manual for more information.
Purpose Embed RFID data into an ALPHA or BARCODE data field.
The RFID Data Indicator character, as defined by the RFREAD parameter in the ALPHA or BARCODE commands. See the ALPHA and/or BARCODE command description for details.
position The decimal number that specifies the starting position of the data inside the transponder.
length The decimal number that specifies the length of the data to be read.
format Replace the optional format parameter with any non-zero number to convert the data to hexadecimal format.
Format position,length[,format];

Get Tag Unique ID
Purpose Read the unique identification number of the RFID tag (embedded in the smart label).
^RI Get Tag Unique ID command.
x The field number to which the data will be assigned. The default is 0, and other acceptable values range from 1 to 9999.
The PPI1 only supports Alien Technology Class 1a tags, which do not have the unique identification numbers. Therefore, the PPI1 absorbs this command.
Purpose Select the type of the RFID tag (embedded in the smart label).
^RS Set Tag Type command.
x Number assigned to the type of the tag. The default is 0, and other acceptable values range from 1 to 9999.
The PPI1 only supports Alien Technology Class 1a tags. There are no alternative choices. Therefore, the PPI1 absorbs this command.

Read Tag
Purpose This command allows data from the RFID tag (embedded in the smart label) to merge into any previously defined dynamic data field. It is equivalent to the Field Number command (^FN) except that the data come from the RFID tag.
Format ^RT x, start, length, hex, retries, motion, reserved
^RT Read Tag command.
x Specified Field Number (value assigned to the field). The default is 0. The acceptable value range is 0 to 9999.
start Location where data will be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, start will be set to 0, regardless of the specified value.
length The number of blocks to be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, length will be set to 1, regardless of the specified value.
hex This flag indicates whether the data, after being read from the RFID tag, should be translated into hexadecimal format. The default is 0, meaning the data will not be translated. The other acceptable value is 1, meaning the data will be translated into hexadecimal format.
retries The number of automatic attempts to read data from the tag if previous reads failed. The PPI1 absorbs the number and uses the value on the control panel’s LCD.

motion Set this flag to 1 to read data from the tag without moving the label. The printer may adjust the label position while it reads data from the tag, but this adjustment will reverse before any subsequent normal label movement. Even if this flag is set to 1, other commands (i.e., alpha or barcode) may move the label. The default is 0.
reserved This is a reserved flag. The PPI1 absorbs this number.
This command is only executed by the demand for data from any dynamic field. The PPI1 absorbs this command if there are no demands for the data.
Purpose This command programs data into an RFID tag (embedded in the smart label).
Format ^WT start, retries, motion, protect, data format, reserved
^WT Write Tag command.
start Starting block location where data will be programmed into the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, start will be set to 0, regardless of the specified value.
retries The number of automatic attempts to write data into the tag if previous writes failed. The PPI1 absorbs the number and uses the value on the control panel’s LCD.
motion Set this flag to 1 to program data into the tag without moving the label. The printer may adjust the label position while it writes data into the tag, but this adjustment will reverse before any
Write Tag · Comments

subsequent normal label movement. Even if this flag is set to 1, other commands (i.e., alpha or barcode) may move the label.
protect This flag indicates whether the data should be protected from being overwritten later. The default is 0, meaning the data are not protected. Other acceptable values are 1 to 255, meaning the data are protected using this number as the LOCK password.
data format 0 (ASCII) or 1 (hex). The default is 0.
reserved This is a reserved flag. The PPI1 absorbs this number.
Purpose This command sends back the data in a ^FN (Field Number) field to the host.
^HV Host Verification command.
x Specified Field Number. The default is 0. The acceptable value range is 0 to 9999.
y Number of characters to be returned. The default is 8. The acceptable value range is 0 to 256.
Header (in uppercase ASCII characters). The default is None. The acceptable value range is 0 to 256 characters.
TAGNO = 48454C4C4F544147
Format ^HVx,y · Example of Use · Example of Response

PPI1 EPC Programming Examples
This programming example programs data into an RFID tag and prints the encodation onto a smart label.
//Begin ZPL form.
//Write Tag with data = “87D0034567ABCDEF” //(hex format).
//Read Tag into data element 1, 8–byte (16 characters) //long (hex format).
//Print data in element 1.
//End and print label.
Same as Example 1, except an alternative PPI1 syntax that does not require underscores between the hex characters is used.
//Begin ZPL form.
//Write Tag with data = “87D0034567ABCDEF” //(hex format).
//Read Tag into data element 1, 8–byte (16 characters) //long (hex format).
//Print data in element 1.
//End and print label.
Example 1 · Example 2

Software Migration Tools (SMT)
There are SMTs for six separate end-use applications supporting both PGL and PPI1 datastreams for a total of 12 tools. Each tool intercepts bar code data in a host datastream and copies the data to an RFID tag (embedded in a smart label) according to a set of rules as defined below. SMTs assume that only one bar code of the type being processed is present. In the event that there is more than one of a given type of barcode present, only the first is processed.
Bar code information encoded as dynamic data is supported. To avoid ambiguity, where bar code data is provided in the form of dynamic data, the RFID tag will be encoded with only the contents of the first variable bar code field. It is your responsibility to ensure that the first variable bar code is the desired bar code.

locations on each form definition. Each time the form prints, a single command enters new data into those locations supplied in the datastream after form definition has been completed.
Tools List

Selecting The Tools

The RFID encoder can detect a number of errors. When one of these errors occurs, the RFID encoder alerts the printer to perform the currently selected error action (see “Error Handling” on page 18) and display the appropriate error message on the control panel’s LCD (see Table 2).
Table 2. Control Panel Error Messages
Error Message Explanation Solution
RFID MAX RETRY Check System
Error Handling = Overstrike in the RFID CONTROL menu, and the Label Retry count has been exhausted.
Press PAUSE to clear the message. See “Troubleshooting” on page 48.
RFID Comm Err Check Cable
RFID error: communication cannot be established with the RFID encoder. Reader will be set to Disable in the RFID CONTROL menu and the previous port settings restored.
Press PAUSE to clear the message. See “Troubleshooting” on page 48.
RFID TAG FAILED Check Media
Error Handling = Stop in the RFID CONTROL menu, and the RFID encoder could not read the RFID tag.
Press PAUSE to clear the message. See “Troubleshooting” on page 48.
Selecting The Tools

Troubleshooting
If you are having trouble with the RFID encoder, consult Table 3 for a list of symptoms and possible solutions.
Table 3. Troubleshooting the RFID Encoder
No communication between the printer and the reader
Tag failed 1. The label could be misaligned. Perform the Auto Calibrate procedure to ensure the label is at top-of-form. See “Running Auto Calibrate” in the Quick Setup Guide.
Inconsistent results Make sure the media is loaded correctly. See “Loading Media And Ribbon” in the Quick Setup Guide.
The RFID encoder works, but it does not meet expectations
Make sure that both Error Handling and Label Retry are set to desired values in the RFID CONTROL menu.
Symptom Solution

Selecting The Tools · Troubleshooting




Distributor/VAR/Reseller for service.
For further assistance, contact the Printronix Customer Support Center.
Americas (714) 368-2686 Europe, Middle East, and Africa (31) 24 6489 410 Asia Pacific (65) 6548 4114 Web site: http://www.printronix.com/public/servicessupport/default.aspx
Americas (800) 733-1900 Europe, Middle East, and Africa (33) 1 46 25 1900 Asia Pacific (65) 6548 4116 or (65) 6548 4182 Web site: http://www.printronix.com/public/supplies/default.aspx
Printronix, Inc. 14600 Myford Road P.O. Box 19559 Irvine, CA 92623-9559 Phone: (714) 368-2300 Fax: (714) 368-2600
Printronix Schweiz Gmbh 42 Changi South Street 1 Changi South Industrial Estate Singapore 486763 Phone: (65) 6542 0110 Fax: (65) 6543 0220
Printronix, Inc. Nederland BV P.O. Box 163 Nieuweweg 283 NI-6600 Ad Wijchen The Netherlands Phone: (31) 24 6489 489 Fax: (31) 24 6489 499
Or visit the Printronix web site at www.printronix.com
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No communication between the printer and the reader | 1. Make sure Reader = Enable in the RFID CONTROL menu. 2. Use the RFID Test option in the RFID CONTROL menu (Admin User enabled) to read and display the current RFID tag content. Class 1 RFID tags usually contain a valid entry due to the pre-test process. See “RFID Test (This Test Reads A Tag)” on page 22. | p.48 | |
| Tag failed | 1. The label could be misaligned. Perform the Auto Calibrate procedure to ensure the label is at top-of-form. See “Running Auto Calibrate” in the Quick Setup Guide. 2. Make sure the media are smart labels with RFID tags located in the correct position. 3. The RFID tag could be defective. Try another tag. 4. Make sure the application does not send too few or too many digits to the RFID tag. | p.48 | |
| Inconsistent results | Make sure the media is loaded correctly. See “Loading Media And Ribbon” in the Quick Setup Guide. | p.48 | |
| The RFID encoder works, but it does not meet expectations | Make sure that both Error Handling and Label Retry are set to desired values in the RFID CONTROL menu. | p.48 |