Developer’s Kit
and Smart Label Pilot Printer
Quick Setup Guide

T M Series of Thermal Printers

the following materials:
The CD-ROM is located in a plastic pocket in the back cover.
Do not discard this guide. If you move or pack the printer in the future, you will need to follow the instructions in this guide.
Distributor/VAR/Reseller for service.
For further assistance, contact the Printronix Customer Support Center.
Printronix Customer Support Center contact information: Americas 1-714-368-2686 Europe, Middle East, and Africa (31) 24 6489 410 Asia Pacific (65) 65484114 Web site: http://www.printronix.com/public/servicessupport/default.aspx
Genuine Printronix Supplies: Americas 1-800-733-1900 Europe, Middle East, and Africa 33.1.46.25.1900 Asia Pacific (65) 65484116 or (65) 65484182 Web site: http://www.printronix.com/public/supplies/default.aspx
Or visit the Printronix web site at www.printronix.com

The Printronix T5000 e Series of Thermal Printers RFID Smart Label Developer’s Kit and Smart Label Pilot Printer Quick Setup Guide

CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING THIS PRINTER. USING THIS PRINTER INDICATES YOUR ACCEPTANCE OF THESE TERMS AND CONDITIONS. IF YOU DO NOT AGREE TO THESE TERMS AND CONDITIONS, PROMPTLY RETURN THE PRINTER AND ALL ACCOMPANYING HARDWARE AND WRITTEN MATERIALS TO THE PLACE YOU OBTAINED THEM, AND YOUR MONEY WILL BE REFUNDED.
Definitions.
“Software” shall mean the digitally encoded, machine-readable data and program. The term “Software Product” includes the Software resident in the printer and its documentation. The Software Product is licensed (not sold) to you, and Printronix, Inc. either owns or licenses from other vendors who own, all copyright, trade secret, patent and other proprietary rights in the Software Product.
License.
a. To protect the proprietary rights of Printronix, Inc., you agree to maintain the Software Product and other proprietary information concerning the typefaces in strict confidence.
b. You agree not to duplicate or copy the Software Product.
c. You shall not sublicense, sell, lease, or otherwise transfer all or any portion of the Software Product separate from the printer, without the prior written consent of Printronix, Inc.
d. You may not modify or prepare derivative works of the Software Product.
e. You may not transmit the Software Product over a network, by telephone, or electronically using any means; or reverse engineer, decompile or disassemble the Software.
f. You agree to keep confidential and use your best efforts to prevent and protect the contents of the Software Product from unauthorized disclosure or use.
Limited Software Product Warranty
Printronix, Inc. warrants that for ninety (90) days after delivery, the Software will perform in accordance with specifications published by Printronix, Inc. Printronix, Inc. does not warrant that the Software is free from all bugs, errors and omissions.
Your exclusive remedy and the sole liability of Printronix, Inc. in connection with the Software is replacement of defective software with a copy of the same version and revision level.
Disclaimer of Warranties and Limitation of Remedies
Software License Agreement · Remedy

2. IN NO EVENT WILL PRINTRONIX, INC. BE LIABLE FOR LOST PROFITS, LOST DATA, BUSINESS INTERRUPTIONS, OR ANY OTHER DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THIS PRODUCT, EVEN IF PRINTRONIX, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR ANY DAMAGES CAUSED BY THE ABUSE OR MANIPULATION OF THE SOFTWARE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
Termination of License Agreement
This License shall continue until terminated. This license may be terminated by agreement between you and Printronix, Inc. or by Printronix, Inc. if you fail to comply with the terms of this License and such failure is not corrected within thirty (30) days after notice. When this License is terminated, you shall return to the place you obtained them, the printer and all copies of the Software and documentation.
U.S. Government Restricted Rights
Use, duplication or disclosure by the Government is subject to restrictions as set forth in the Rights in Technical Data and Computer Software clause at FAR 242.227-7013, subdivision (b) (3) (ii) or subparagraph (c) (1) (ii), as appropriate. Further use, duplication or disclosure is subject to restrictions applicable to restricted rights software as set forth in FAR 52.227-19 (c) (2).
Acknowledgement of Terms and Conditions
YOU ACKNOWLEDGE THAT YOU HAVE READ THIS AGREEMENT, UNDERSTAND IT, AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS. NEITHER PARTY SHALL BE BOUND BY ANY STATEMENT OR REPRESENTATION NOT CONTAINED IN THIS AGREEMENT. NO CHANGE IN THIS AGREEMENT IS EFFECTIVE UNLESS WRITTEN AND SIGNED BY PROPERLY AUTHORIZED REPRESENTATIVES OF EACH PARTY. BY USING THIS PRINTER, YOU AGREE TO ACCEPT THE TERMS AND CONDITIONS OF THIS AGREEMENT.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Printronix is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by any unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
Communication Notices

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any change or modification to this product voids the user’s authority to operate it per FCC Part 15 Subpart A Section 15.21 regulations.
This product contains an intentional radiator with the following parameters: Operating Frequency: 902-928 MHz Typical RF Power: 25-100 miliwatts Maximum RF Power: 1 Watt under abnormal conditions
Canadian Department of Communications Compliance Statement: This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformite aux normes du ministere des Communcations du Canada: Cet appareil numerique de la classe A est conform á norme NMB-003 du Canada.
European Community (EC) Conformity Statement: This product is in conformity with the protection requirements of EC Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Printronix cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-Printronix option cards.
Dieses Gerät ist berechtigt in Übereinstimmung mit dem deutschen das EG-Konformitätszelchen - CE - zu führen.
Der Außteller der Konformitätserklärung ist die Printronix (1)
Informationen in Hinsicht EMVG Paragraph 3 Abs. (2) 2:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
EN 55022 Klasse A Geräte bedürfen folgender Hinweise:
Nach dem EMVG: “Geräte dürfen an Orten, für die sie nicht asreichend entstört sind, nur mit besonderer Genehmigung des Bundesminesters für Post und Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen Störungen zu erwarten sind.” (Auszug aus dem EMVG, Paragraph 3, Abs. 4) Dieses Genehmigungsverfahren ist nach Paragraph 9 EMVG in Verbindung mit der entsprechenden Kostenverordnung (Amtsblatt 14/93) kostenpflichtig.
Nach der EN 55022: “Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen und dafür aufzkommen.”
Anmerkung: Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in den Handbüchern angegeben, zu installieren und zu betreiben.

This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.




Printronix makes no representations or warranties of any kind regarding this material, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. Printronix shall not be held responsible for errors contained herein or any omissions from this material or for any damages, whether direct, indirect, incidental or consequential, in connection with the furnishing, distribution, performance or use of this material. The information in this manual is subject to change without notice.
This document contains proprietary information protected by copyright. No part of this document may be reproduced, copied, translated or incorporated in any other material in any form or by any means, whether manual, graphic, electronic, mechanical or otherwise, without the prior written consent of Printronix.
COPYRIGHT © 2004 PRINTRONIX, INC. All rights reserved.
Alien Technology is a trademark of Alien Technology Corporation.
Manhattan Associates is a registered trademark of Manhattan Associates, Inc.
Printronix, PGL, and PrintNet are registered trademarks of Printronix, Inc.
T5000e is a trademark of Printronix, Inc.
Uniform Code Council is a registered trademark of Uniform Code Council, Inc.
Zebra and ZPL are trademarks of Zebra Technologies Corporation.
Trademark Acknowledgements


Overview
Congratulations on your purchase of the industry’s first Smart Label Developer’s Kit or Smart Label Pilot Printer. The intent of the kit is to provide a complete environment for the printing and encoding of RFID smart labels right out of the box. Printronix has specifically designed this kit to help you fast track your RFID pilot printer application through the use of a suite of Software Migration Tools (SMT).

The Printronix Smart Label Developer’s Kit also contains:
Smart labels are based on an EEPROM technology that requires some time to be programmed. You may notice this minor pause between labels. This time is necessary to better ensure consistent quality and improved reliability.
When dealing with smart labels, it is possible that an occasional RFID tag may need to be written and verified more than once (retry) before being considered acceptable. In this event each retry time will be added to the inter-label pause.
Static electricity can damage the smart labels. Open the media cover of the printer and touch an unpainted metal part of the printer before you handle smart labels. This will discharge any static electricity that may have built up on your hands.

If an RFID tag within a smart label is deemed unacceptable after execution of the defined number of retries, the following actions are performed:
The smart labels currently supported have the following characteristics:
purchased directly from Printronix to assure the highest level of performance and reliability. See “How To Order More Smart Labels” on page 15.
Overstruck Smart Labels

Transitioning From UCC/GTIN Applications Using Printronix Software Migration Tools (SMT)
It is likely that your software is already set up to create bar codes. You may have also spent a lot of time creating compliance label templates & integrating them into your system. The Smart Label Developer’s Kit Software Migration Tools will allow you to effortlessly transition from printing compliance labels to smart labels.
If you are printing bar codes now, you can print smart labels — no change to your host data stream or existing compliance templates is required.

What We Can Do
The existing toolset will meet the needs of many RFID early adopters. If you have a requirement for a Software Migration Tool not included in this kit, feel free to contact Printronix.
To select and use the tools, see “Software Migration Tools (SMT)” on page 65.
To order more RFID smart labels, contact Printronix: 1-800-733-1900 www.printronix.com
Part Number Roll of 500 4 x 6 inch EPC Class 1 smart labels with squiggle antenna inlay: 204932-001
Printronix can partner with you on your RFID pilot project to make your existing software applications RFID/smart label capable. We specialize in AutoID Consulting, compliance labeling, third party software integration, and label generation.
Printronix Customer Support Center 1-714-368-2686 Ask for Professional Services Support

Hardware/Infrastructure Considerations
Once your smart labels have been applied to their target container or pallet you will need external readers to track them through your supply chain. Such readers are typically networked devices that are deployed at key points in the warehouse or distribution center to track incoming and outgoing packages. The readers are managed through a server for gathering and filtering all the RFID information. Readers may have multiple antennas to maximize read range and reliability.
The readers you purchase must be compatible with the smart labels programmed by the printer. Specifically, they should be EPC Class 1 compliant. Fixed position readers and their antennas can be purchased from Alien Technology (www.alientechnology.com). Handheld readers with integrated antennas can be purchased from AWID (www.awid.com).
The data that are gathered by the reader servers must be managed for tracking and archiving purposes. Software applications that perform these tasks are available from companies such as Manhattan Associates® (www.manh.com).

EPCglobal, Inc. www.epcglobalinc.org
Auto-ID Labs www.autoidlabs.org
Uniform Code Council, Inc.®
RFID Journal www.rfidjournal.com
Alien Technology® Corporation www.alientechnology.com
Applied Wireless Identifications Group, Inc. www.awid.com
Reference Material


Unpacking And Installing The Printer
The printer is shipped in a carton and protective bag. Keep all packing material in case shipping is required.


Remove the tape strips and foam pads from the printer as indicated below. (The top lid of the shipping carton also displays these instructions.)



In compliance with international safety standards, this printer has been equipped with a three-pronged power cord. Do not use adapter plugs or remove the grounding prong from the cable plug. If an extension cord is required, ensure that a three-wire cable with a properly grounded plug is used.
Installation

Controls And Indicators
Power Switch
The power switch is located on the bottom back panel of the printer. To apply power, place the switch in the | (On) position. When you first power on the printer, a series of initialization messages appears on the Liquid Crystal Display (LCD) on the control panel.
To remove power, place the power switch in the O (Off) position.
The control panel is located on the front of the printer and includes an LCD, indicators, and control keys (buttons). These are described in the following tables.

Liquid Crystal Display (LCD)

During a fault condition,
Flashes during a fault
fault message and the
Offline Mode Function in
submenu, or option.
and a main menu,
corrective action.
condition.
Off.
During a fault condition,
Stays lit when data has
been processed and is
being received or when
Off when the printer is
Flashes during a fault
fault message and the
no data remains in the
Displays “OFFLINE.”
waiting to be printed.
Off when no data is
Online Mode Function in
corrective action.
condition.
offline.
buffer.
data.
During a fault condition,
Stays lit when data has
been processed and is
being received or when
printer is online, ready
Flashes during a fault
fault message and the
no data remains in the
to print, and accept
waiting to be printed.
Off when no data is
Indicator Description Function in
Stays lit when the
data from the host.
emulation in use.
corrective action.
condition.
buffer.
data.
Online Status Indicates when the
Process Indicates when the
characters each.
there is a fault
Display (LCD) A backlighted
condition.
data.

Control Panel Keys
Offline mode. Sets printer to Online mode. Sets printer to Offline mode.
Print patterns. Scrolls right through main
Scrolls left through main
label length. Scrolls the current menu
selection one level up.
Offline Mode Function in
within submenus.
within submenus.
menus.
menus.
you to load the factory and/
number of the last loaded
Advances the media one
JOB SELECT Key None Displays the name and
None Scrolls through the Test
Online Mode Function in
configurations.
Button Description Function in
length.
UP Key in Menu mode
test. Pressing ↵ again
(ENTER) key with a
terminates the test.
Offline modes.

Menu mode. Scrolls between main
(*) next to the value.
None None Selects the current
Offline Mode Function in
menu selections.
level down.
None Clears all data
when enabled.
Online Mode Function in
selects the Menu mode. Selects the
MENU Key Takes the printer Offline and
Button Description Function in
enabled, pressing it will clear all
Pressing the ↵ (ENTER) key in
the option or value indicating it
LOCKED” displays on the LCD
(DOWN) and ↵ (ENTER) keys
at the same time to unlock the
data in the printer buffer and
installed, the default = Enable.
displayed option or value. An
asterisk then appears next to
prevent printing of that data.
DOWN Key in Menu mode
When the CANCEL key is
However, when the Coax/
Twinax Interface option is
for one second. Press the
Menu mode selects the
has been selected.
ENTER key.



Pivoting · Deck · Lever


Loading Roll Media · Media Hanger · Media Hanger Guide



Media and Ribbon Loading Instructions
RFID tag must be in proximity of the antenna when the RFID tag is programmed.
Media · Antenna · RFID Encoder


Loading Roll Media · Media Damper




Media (left edge) · Deck Lock Lever


Thereafter, use the core from the old (used up) ribbon.



Rear Ribbon Guide Roller
Printhead · Media


Media and Ribbon Loading Instructions
Loading Ribbon · Ribbon Take-up Core · Ribbon Take-up Spindle



Adjust the printhead pressure to the setting of 4.
Manually adjust the left pressure block so its handle is aligned with the bold mark on the pressure block adjustment scale.
Use the lead screw knob to position the right pressure block with its pointer near the right edge of the media in use.

Positioning The Media Sensors

Lower Media Sensor Handle (2)
Your printer is equipped with upper and lower media sensors that detect the top-of-form position on media with label length indicators (gaps, notches, holes, or black marks). The media sensors also detect Paper Out conditions.
Use the handles on the lower media sensor to horizontally position it in the center of the installed media. Slide the upper media sensor, located in the slot under the printhead cover (see figure on page 34), directly over the lower sensor.

Running Auto Calibrate
Due to manufacturing differences in media and ribbon, the media sensor may have difficulty distinguishing between the label and the liner (gap).
To ensure proper operation, you must now run Auto Calibrate:
see page 38.

Positioning The Media Sensors
Before you send an actual print job, run a barcode demo test:
test.



4 or 6 inches* 2, 4 00.1 to 99.0 inches5
Gap/Mark Sensor Disable* Mark Gap Advanced Notch Advanced Gap
1 Maximum value depends on the width of the printer model and printhead.
2 You can change the unit value from inches to millimeters under Units (in MEDIA CONTROL) Refer to the User’s Manual for information.
(cont. on next page)
3 Based on the current value setting for the Label Length menu, up to a maximum of 12.80 inches.
4 Maximum value depends on the width of the printer model.
5 Maximum value depends on model width and size of DRAM installed.

QUICK SETUP (cont. from previous page)
Toolset [1]* Toolset [1] to Toolset [4] SMT: Sel Toolset
zUCC1282, 3 GTIN1
EAN8 1
EAN13 1
UCC128 1
1 Appears only if Toolset [1] is selected under SMT: Sel Toolset.
2 Appears only if Toolset [2] is selected under SMT: Sel Toolset.
3 Undocumented options are reserved for internal use and future design.
Specifies the level of thermal energy from the printhead to be used for the type of media and ribbon installed.
Large numbers imply more heat (thermal energy) to be applied for each dot. This has a significant effect on print quality. The print intensity and speed must match the media and ribbon type to obtain the best possible print quality and barcode grades.
The range is -15 through +15:

Print Speed
Specifies the speed in inches per second (ips) at which the media passes through the printer while printing.
The range is 2 through 10 ips (in increments of 1 ips).
The default is 6 ips.
printer width and dot per inch (dpi) resolution of the printhead installed (203 or 300 dpi).
The default is Transfer.

encoder. • Continuous. Printer prints on the media and sends it out the front.
The default is Tear-Off Strip.
Represents the distance to advance a label (+ shift) or pull back (– shift) when the Tear-Off Strip, Tear-Off, Peel-Off, or Cut Media Handling option is enabled. The allowable range is -0.50 inches to the current Label Length value setting up to a maximum of 12.80 inches in 0.01 inch increments.
The default is 0.00 inches.
In most applications, the user-selected Label Length will match the physical label length. Physical label length is the actual label length of the media installed. Following is a list of different media types:
QUICK SETUP Submenus

Label Width
The allowable range in inches is 00.1 to the maximum print width of the printer. The allowable range in millimeters is 2.5 to the maximum width of the printer.
Specifies the amount to shift an image up (-) or down (+) for precise positioning on the label. The actual height of the image is not affected by this parameter. The allowable range is -1.00 inches to the current Label Length value setting, up to a maximum of 12.80 inches in 0.01 inch increments.
The default value is 0.00 inches.
Specifies the amount to shift an image left (-) or right (+) for precise positioning on the label. The actual width of the image is not affected by this parameter. The allowable range is -1.00 through +1.00 inches in 0.01 inch increments, displayed as xx/100.
The default value is 0.00 inches.
Specifies the image orientation to be used when printing the label. • Portrait. The default. Portrait refers to vertical page orientation, where the height of a page is greater than its width. The top edge of the image is parallel to the leading edge of the media. The following example is viewed from the front of the printer.
The top edge of the image is parallel to the leading edge of the media.
4” · 6” · Leading Edge

The top edge of the image is parallel to the trailing edge of the media.
edge of the media.
parallel to the left
The top edge of

The top edge of the image is parallel to the right edge of the media.
Specifies the sensor type needed for detecting the top-of-form position on media with label length indicators (gaps, notches, holes, or black marks). • Disable. Select when using media with no label length indicators (no gaps, notches, holes, or black marks), or when you want the printer to ignore all existing label length indicators on the installed media.
4” · 6” · Leading Edge

The default is Disable.
This feature is used to improve the sensitivity and reliability of the media sensor in detecting gaps, notches, holes, or black marks on the installed media, as well as a Paper Out condition.
To initiate Auto Calibrate, scroll to the “Auto Calibrate” menu and press the ↵ key. The printer will advance media the distance needed to accurately detect the label length indicators, then stop at the top-of-form position and momentarily display the Sensed Distance. This process takes a few seconds and results in an update of the printer values.
Auto Calibrate is completed successfully when the Sensed Distance displayed correctly matches that of the installed media. When you select Gap, the Sensed Distance should match the length from the trailing edge of one gap to the trailing edge of the next gap (one label + one gap). When you select Mark, the Sensed Distance should match the length from the leading edge of one black mark to the leading edge of the next black mark.
Auto Calibrate supports label lengths up to 24 inches.
Save Config.
Allows you to save up to eight unique configurations to meet different print job requirements. This eliminates the need to change the parameter settings for each new job. The configurations are stored in memory and will not be lost if you turn off the printer. The default is 1.
QUICK SETUP Submenus

Power-Up Config.
You can specify one of the eight configurations as the power-up configuration. The default is Factory.
See “Software Migration Tools (SMT)” on page 65. • Disabled.The printer disables the use of the Software Migration Tools.
See “Software Migration Tools (SMT)” on page 65. • EPC, GTIN, UPCA, EAN8, EAN13, and UCC128. SMTs displayed if Toolset [1] is selected under SMT: Sel Toolset.
future design.

This chapter has provided general information for use of your printer. The next chapter provides information about the RFID encoder.
QUICK SETUP Submenus


Overview
This chapter describes how to use the RFID encoder. The RFID encoder is designed to be transparent to the printer operation. It provides the capability of programming smart labels (with embedded RFID tags) while printing the label format. The smart labels are provided with the printer or purchased separately from Printronix.
There are several ways to program RFID tags in smart labels:



Alien Squig 96 Alien M-TAG 64 Alien M-TAG 96
RAF Omni 313 64 RAF Omni 313 96 Matrics X2020 96
Italicized items are available only when you enable Admin User in the PRINTER CONTROL menu.
(cont. on next page)

RFID CONTROL (cont. from previous page)
Custom Tag Len 8* 8 to 32
Custom Tag Class Class 1* Class 0 Class 0+
Italicized items are available only when you enable Admin User in the PRINTER CONTROL menu.
This menu item enables or disables the RFID encoder. The default is Enable.
This menu item selects the error handling mode for RFID failures. The default is Overstrike.
In Overstrike mode, each failed label prints with the Overstrike pattern and the form retries on a new label until the Label Retry count is exhausted. At this time, the error message “RFID Error: Check Media” displays. The failed label will not reprint.
In None mode, no specific action is taken when a tag fails to be programmed.
In Stop mode, when a tag fails to be programmed, the printer will halt and display the error message “RFID Error: Check Media.” The label is discarded and reprinting of the label (if desired) must be initiated from the host. When the error is cleared, the label with the failed tag moves forward until the next label is in position to be printed.
RFID CONTROL Submenus

Label Retry
set to Overstrike.
This menu item selects the number of label retries that the RFID encoder will attempt before declaring a fault. This may indicate a problem with the RFID encoder, the antenna assembly, the printer setup, or the label stock. The default is 10.
This menu item enables or disables the Max Retry Error menu item. If it is set to Disable, errors are not declared and the print content for the current label is discarded. The default is Enable.
This menu item displays on the control panel’s LCD the number of tags written since the last Clear Tag Stat operation has been initiated. (See “Clear Tag Stat” below.)
This menu item displays on the control panel’s LCD the number of failed tag write attempts since the last Clear Tag Stat operation has been initiated. (See “Clear Tag Stat” below.)
This menu item clears the Tag Write Cnt and Failed Tag Cnt menu items.
This menu item displays on the control panel’s LCD the reader firmware version.

When this menu item is set to Enable, the RFID encoder checks the tags for a pre-programmed quality code. If the code is absent, the tag immediately fails and the selected Error Handling mode is performed (Overstrike, None, or Stop). The default is Disable.
This menu item selects the style of the overstrike pattern. The default is Grid.
When it is set to Grid, a grid pattern prints when it overstrikes. When it is set to Error Type Msg, an error message prints that indicates which error occurred (see Table 1).
Table 1. Printed Overstrike Error Messages
Tag R/W Err x Check media
The printer software attempted to write to or read from the RFID tag, but the RFID encoder indicated that the tag could not be written to or read from.
Tag Comm Err x Check cable
The printer software temporarily lost communication with the RFID encoder, or communication between the printer software and the RFID encoder was not synchronized and had to be forced.
Precheck Fail x Check media
This failure occurs only when the Precheck Tags menu item is set to Enable. It indicates that the RFID tag was automatically failed since it did not contain the correct pre-programmed quality code.
identifies the area in the printer software where the failure occurred.
RFID CONTROL Submenus · Error Message Explanation

Admin User Menu Items
To see these menu items, set Admin User to Enable in the PRINTER CONTROL menu. (Refer to the User’s Manual.)
This menu item selects the tag type in use. The default is Alien Squig 64. Other classes may be added in the future.
This menu item reads the tag in range of the internal RFID antenna and reports the tag data to the debug port and momentarily displays it on the control panel’s LCD. It is primarily intended for development verification by checking that the system is working.
This menu item selects the number of automatic (internal) retries that the RFID encoder will attempt on the same tag before declaring a tag error and performing the Error Handling mode selected (Overstrike, Stop, or None). The default is 2.
This menu item enables or disables the Custom Pwr Set, Custom Tag Len, and Custom Tag Class menu items (custom tag menus). The default is Disable.
The custom tag menus allow the RFID encoder to work with tag types that are not listed in the Tag Type menu item.
not certified by Printronix.

Admin User Menu Items
When Custom Tag is set to Disable, the settings in the custom tag menus are ignored by the RFID encoder.
When it is set to Enable, the RFID encoder uses the settings in the custom tag menus, which must be set to match the characteristics of the custom tag.
When it is set to Duplicate, the settings of the selected Tag Type menu item are copied into the custom tag menus.
This menu item selects the power level to be used in the RFID encoder. 1 is the lowest power level setting, and 20 is the highest. The default is 5.
This menu item selects the number of bytes in the tag. The default is 8.
This menu item selects the class of the custom tag. Class 1 and Class 0+ tags are read/write. Class 0 tags are read only. The default is Class 1.

RFID PGL Commands
Write Tag
Purpose To program non-incremental data into an RFID tag (embedded in the smart label).
RFWRITE; The RFID Write Tag command.
HEX; Optional parameter to indicate that the text in datafield is in hexadecimal format and that it will be converted to binary format.
EPCm; Optional parameter to indicate that the data in datafield should be converted to an EPC number. When this parameter is used, the HEX option is automatically enabled and the data field is limited to a maximum of 14 digits. The AT parameter is ignored. The tag is then programmed as follows:
Bits 0 to 1 are programmed with the EPC value 0 to 3, specified in m.
Bits 2 to 57 are programmed with the hexadecimal characters in the data field (14 maximum). If the data field has less than 14 hexadecimal characters, zeros are assumed for the remaining digits.
Bits 58 to 63 are set to zero.
RFn;L; Optional parameter to indicate that this field has dynamic data. Replace n with a number ranging from 1 to 512 to identify the field number of this RFWRITE field. Replace L with the length of the dynamic data string. If this option is used, the
Format · RFWRITE;[HEX;][EPCm;][RFn;L;][LOCK;]ATp;[(D)datafield(D)]

datafield is ignored, and dynamic data must be entered via the RF command in the EXECUTE mode. The length of the dynamic data must be equal to L.
LOCK; Optional parameter to write-protect the data. Currently not supported.
ATp; p specifies the decimal start position where data will be written to the tag. Subsequent bits will be shifted and previous bits are nulled.
(D) Delimiter designating the start and end of static data for the RFWRITE field. Replace (D) with any printable character, except the SFCC and “/” (the slash character).
datafield The static data of the RFWRITE field.
HDUP sections.
Read Tag is not a command, but an element of the ALPHA and BARCODE commands. See “Alphanumerics” and “Bar Codes” in the IGP/PGL Programmer’s Reference Manual for more information.
Purpose Embed RFID data into an ALPHA or BARCODE data field.
The RFID Data Indicator character, as defined by the RFREAD parameter in the ALPHA or BARCODE commands. See the ALPHA and/or BARCODE command description for details.
position The decimal number that specifies the starting position of the data inside the transponder.
Read Tag · Format position,length[,format];

length The decimal number that specifies the length of the data to be read.
format Replace the optional format parameter with any non-zero number to convert the data to hexadecimal format.
This programming example shows reading and writing dynamic EPC data to a tag.
//Create a form named HEX.
//Write Tag with data from dynamic RFID element 3. //Length of data is 16, format is HEX.
//The following ALPHA element is defined below. //It will be used to print the contents of the tag.
//Read Tag Indicator character is “@”. Incorporate read //data into Dynamic ALPHA field number 1. Length of //ALPHA field is 16 characters. Place ALPHA field at //dot position (10,10) on the form.
//Terminate the ALPHA element definition.
~EXECUTE;HEX
//Execute the form with dynamic data.
//Dynamic data (in HEX) for Tag Write is //“68656C6C6F746167”.
//Print the data in AF1.

This programming example shows reading and writing dynamic ASCII data to a tag.
//Create a form named READTAG.
//Write Tag with data from dynamic RFID element 3. //Length of data is 8.
//The following ALPHA element is defined below. //It will print the contents of the tag.
//Read Tag Indicator character is “@”. Incorporate read //data into Dynamic ALPHA field number 1. Length of //ALPHA field is 8 characters. Place ALPHA field at dot //position (10,10) on the form.
//Terminate the ALPHA element definition.
~EXECUTE;READTAG
//Dynamic data for Tag Write is “hellotag”.
//Execute READTAG form with dynamic and RFID data //from the first eight bytes in the Tag.
ASCII Programming Example · ~RF3;“hellotag”

RFID PPI1 Commands
Get Tag Unique ID
Purpose Read the unique identification number of the RFID tag (embedded in the smart label).
^RI Get Tag Unique ID command.
x The field number to which the data will be assigned. The default is 0, and other acceptable values range from 1 to 9999.
The PPI1 only supports Alien Technology Class 1a tags, which do not have the unique identification numbers. Therefore, the PPI1 absorbs this command.
Purpose Select the type of the RFID tag (embedded in the smart label).
^RS Set Tag Type command.
x Number assigned to the type of the tag. The default is 0, and other acceptable values range from 1 to 9999.
The PPI1 only supports Alien Technology Class 1a tags. There are no alternative choices. Therefore, the PPI1 absorbs this command.

Purpose This command allows data from the RFID tag (embedded in the smart label) to merge into any previously defined dynamic data field. It is equivalent to the Field Number command (^FN) except that the data come from the RFID tag.
Format ^RT x, start, length, hex, retries, motion, reserved
^RT Read Tag command.
x Specified Field Number. The default is 0. The acceptable value range is 1 to 9999.
start Location where data will be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, start will be set to 0, regardless of the specified value.
length The number of blocks to be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, length will be set to 1, regardless of the specified value.
hex This flag indicates whether the data, after being read from the RFID tag, should be translated into hexadecimal format. The default is 0, meaning the data will not be translated. The other acceptable value is 1, meaning the data will be translated into hexadecimal format.
retries The number of automatic attempts to read data from the tag if previous reads failed. The PPI1 absorbs the number and uses the value on the control panel’s LCD.
Read Tag

motion Set this flag to 1 to read data from the tag without moving the label. The printer may adjust the label position while it reads data from the tag, but this adjustment will reverse before any subsequent normal label movement. Even if this flag is set to 1, other commands (i.e., alpha or barcode) may move the label.
reserved This is a reserved flag. The PPI1 absorbs this number.
This command is only executed by the demand for data from any dynamic field. The PPI1 absorbs this command if there are no demands for the data.
Purpose This command programs data into an RFID tag (embedded in the smart label).
Format ^WT start, retries, motion, protect, reserved
^WT Write Tag command.
start Starting block location where data will be programmed into the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, start will be set to 0, regardless of the specified value.
retries The number of automatic attempts to write data into the tag if previous writes failed. The PPI1 absorbs the number and uses the value on the control panel’s LCD.
motion Set this flag to 1 to program data into the tag without moving the label. The printer may adjust the label position while it writes data into the tag, but this adjustment will reverse before any subsequent normal label movement.
Comments

Even if this flag is set to 1, other commands (i.e., alpha or barcode) may move the label.
protect This flag indicates whether the data should be protected from being overwritten later. The default is 0, meaning the data are not protected. Other acceptable values are 1 to 255, meaning the data are protected using this number as the LOCK password.
reserved This is a reserved flag. The PPI1 absorbs this number.
Purpose This command sends back the data in a ^FN (Field Number) field to the host.
^HV Host Verification command.
x Specified Field Number. The default is 0. The acceptable value range is 0 to 9999.
y Number of characters to be returned. The default is 8. The acceptable value range is 0 to 256.
Header (in uppercase ASCII characters). The default is None. The acceptable value range is 0 to 256 characters.
TAGNO = 48454C4C4F544147

EPC Programming Example
^XA
//Begin ZPL form.
//Write Tag with data = “68656C6C6F746167” //(hex format).
//Read Tag into data element 1, 16 characters long //(hex format).
//Print data in element 1.
//End and print label.

There are SMTs for six separate end-use applications supporting both PGL and PPI1 datastreams for a total of 12 tools. Each tool intercepts bar code data in a host datastream and copies the data to an RFID tag (embedded in a smart label) according to a set of rules as defined below. SMTs assume that only one bar code of the type being processed is present. In the event that there is more than one of a given type of barcode present, only the first is processed.
Bar code information encoded as dynamic data is supported. To avoid ambiguity, where bar code data is provided in the form of dynamic data, the RFID tag will be encoded with only the contents of the first variable bar code field. It is your responsibility to ensure that the first variable bar code is the desired bar code.
Tools List

locations on each form definition. Each time the form prints, a single command enters new data into those locations supplied in the datastream after form definition has been completed.

Selecting The Tools

Error Messages
The RFID encoder can detect a number of errors. When one of these errors occurs, the RFID encoder alerts the printer to perform the currently selected error action (see “Error Handling” on page 51) and display the appropriate error message on the control panel’s LCD (see Table 2).
Table 2. Control Panel Error Messages
Error Message Explanation Solution
RFID MAX RETRY Check System
Error Handling = Overstrike in the RFID CONTROL menu, and the Label Retry count has been exhausted.
Press PAUSE to clear the message. See “Troubleshooting” on page 69.
RFID Comm Err Check Cable
RFID error: communication cannot be established with the RFID encoder. Reader will be set to Disable in the RFID CONTROL menu and the previous port settings restored.
Press PAUSE to clear the message. See “Troubleshooting” on page 69.
RFID TAG FAILED Check Media
Error Handling = Stop in the RFID CONTROL menu, and the RFID encoder could not read the RFID tag.
Press PAUSE to clear the message. See “Troubleshooting” on page 69.

If you are having trouble with the RFID encoder, consult Table 3 for a list of symptoms and possible solutions.
Table 3. Troubleshooting the RFID Encoder
No communication between the printer and the reader
Tag failed 1. The label could be misaligned. Perform the Auto Calibrate procedure to ensure the label is at top-of-form. Refer to “Running Auto Calibrate” in the Quick Setup Guide.
Inconsistent results Make sure the media is loaded correctly and passes smoothly over the antenna. Refer to “Loading Media And Ribbon” in the Quick Setup Guide.
Symptom Solution

Table 3. Troubleshooting the RFID Encoder
The RFID encoder works, but it does not meet expectations
Make sure that both Error Handling and Label Retry are set to desired values in the RFID CONTROL menu.
Symptom Solution






Distributor/VAR/Reseller for service.
For further assistance, contact the Printronix Customer Support Center.
Americas 1-714-368-2686 Europe, Middle East, and Africa (31) 24 6489 410 Asia Pacific (65) 65484114 Web site: http://www.printronix.com/public/servicessupport/default.aspx
Americas 1-800-733-1900 Europe, Middle East, and Africa 33.1.46.25.1900 Asia Pacific (65) 65484116 or (65) 65484182 Web site: http://www.printronix.com/public/supplies/default.aspx
Printronix, Inc. 14600 Myford Road P.O. Box 19559 Irvine, CA92623-9559 Phone: 714-368-2300 Fax: 714-368-2600
Printronix Schweiz Gmbh 42 Changi South Street 1 Changi South Industrial Estate Singapore 486763 Phone: 65-6542-0110 Fax: 65-6543-0220
Printronix, Inc. Nederland BV P.O. Box 163 Nieuweweg 283 NI-6600 Ad Wijchen The Netherlands Phone: 31-24-6489-489 Fax: 31-24-6489499
Or visit the Printronix web site at www.printronix.com
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No communication between the printer and the reader | 1. Make sure the serial interface adapter and the serial cable are plugged into the printer. See “Installation” on page 21. 2. Make sure Reader = Enable in the RFID CONTROL menu. 3. Use the RFID Test option in the RFID CONTROL menu (Admin User enabled) to read and display the current RFID tag content. RFID tags usually contain a valid entry due to the pre-test process. See “RFID Test (This Test Reads A Tag)” on page 54. | p.69 | |
| Tag failed | 1. The label could be misaligned. Perform the Auto Calibrate procedure to ensure the label is at top-of-form. Refer to “Running Auto Calibrate” in the Quick Setup Guide. 2. Make sure the media are smart labels with RFID tags located in the correct position. 3. The RFID tag could be defective. Try another tag. 4. Make sure the application does not send too few or too many digits to the RFID tag. | p.69 | |
| Inconsistent results | Make sure the media is loaded correctly and passes smoothly over the antenna. Refer to “Loading Media And Ribbon” in the Quick Setup Guide. | p.69 | |
| The RFID encoder works, but it does not meet expectations | Make sure that both Error Handling and Label Retry are set to desired values in the RFID CONTROL menu. | p.70 |
Owners and our team usually reply within a day — and your question helps the next person too.