P5000LJ Series Printers
User’s Manual



P5000LJ Series Printers
User’s Manual

USING THIS PRINTER
Software License Agreement
CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING THIS PRINTER. USING THIS PRINTER INDICATES YOUR ACCEPTANCE OF THESE TERMS AND CONDITIONS. IF YOU DO NOT AGREE TO THESE TERMS AND CONDITIONS, PROMPTLY RETURN THE PRINTER AND ALL ACCOMPANYING HARDWARE AND WRITTEN MATERIALS TO THE PLACE YOU OBTAINED THEM, AND YOUR MONEY WILL BE REFUNDED.
Definitions.
“Software” shall mean the digitally encoded, machine-readable data and program. The term “Software Product” includes the Software resident in the printer and its documentation. The Software Product is licensed (not sold) to you, and Printronix either owns or licenses from other vendors who own, all copyright, trade secret, patent and other proprietary rights in the Software Product.
License.
a. To protect the proprietary rights of Printronix, you agree to maintain the Software Product and other proprietary information concerning the typefaces in strict confidence.
b. You agree not to duplicate or copy the Software Product.
c. You shall not sublicense, sell, lease, or otherwise transfer all or any portion of the Software Product separate from the printer, without the prior written consent of Printronix.
d. You may not modify or prepare derivative works of the Software Product.
e. You may not transmit the Software Product over a network, by telephone, or electronically using any means; or reverse engineer, decompile or disassemble the Software.
f. You agree to keep confidential and use your best efforts to prevent and protect the contents of the Software Product from unauthorized disclosure or use.

Printronix warrants that for ninety (90) days after delivery, the Software will perform in accordance with specifications published by Printronix. Printronix does not warrant that the Software is free from all bugs, errors and omissions.
Your exclusive remedy and the sole liability of Printronix in connection with the Software is replacement of defective software with a copy of the same version and revision level.
2. IN NO EVENT WILL PRINTRONIX BE LIABLE FOR LOST PROFITS, LOST DATA, BUSINESS INTERRUPTIONS, OR ANY OTHER DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THIS PRODUCT, EVEN IF PRINTRONIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR ANY DAMAGES CAUSED BY THE ABUSE OR MANIPULATION OF THE SOFTWARE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This License shall continue until terminated. This license may be terminated by agreement between you and Printronix or by Printronix. If you fail to comply with the terms of this License and such failure is not corrected within thirty (30) days after notice. When this License is terminated, you shall return to the place you obtained them, the printer and all copies of the Software and documentation.

Use, duplication or disclosure by the Government is subject to restrictions as set forth in the Rights in Technical Data and Computer Software clause at FAR 242.227-7013, subdivision (b) (3) (ii) or subparagraph (c) (1) (ii), as appropriate. Further use, duplication or disclosure is subject to restrictions applicable to restricted rights software as set forth in FAR 52.227-19 (c) (2).
YOU ACKNOWLEDGE THAT YOU HAVE READ THIS AGREEMENT, UNDERSTAND IT, AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS. NEITHER PARTY SHALL BE BOUND BY ANY STATEMENT OR REPRESENTATION NOT CONTAINED IN THIS AGREEMENT. NO CHANGE IN THIS AGREEMENT IS EFFECTIVE UNLESS WRITTEN AND SIGNED BY PROPERLY AUTHORIZED REPRESENTATIVES OF EACH PARTY. BY USING THIS PRINTER, YOU AGREE TO ACCEPT THE TERMS AND CONDITIONS OF THIS AGREEMENT.
Printronix makes no representations or warranties of any kind regarding this material, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. Printronix shall not be held responsible for errors contained herein or any omissions from this material or for any damages, whether direct, indirect, incidental or consequential, in connection with the furnishing, distribution, performance or use of this material. The information in this manual is subject to change without notice.
This document contains proprietary information protected by copyright. No part of this document may be reproduced, copied, translated or incorporated in any other material in any form or by any means, whether manual, graphic, electronic, mechanical or otherwise, without the prior written consent of Printronix.
COPYRIGHT © 2000, 2003 PRINTRONIX, INC.
All rights reserved.

Hewlett-Packard, HP, HP-UX, Bi-Tronics, HP in a circle, Hewlett Packard, PCL and HP rounded rectangle are registered trademarks of Hewlett-Packard Company.
AIX, AS/400, IBM, NetView, Proprinter and OS/2 are registered trademarks, and AFP, Intelligent Printer Data Stream, IPDS, Print Services Facility, and PSF are trademarks of International Business Machines Corporation.
IBM and Proprinter are registered trademarks, and PC-DOS is a trademark of International Business Machines Corporation.
Portions of this manual used by permission of Wyndham Technologies, Inc. Copyright © 1991-1999 Wyndham Technologies Inc.
ANSI is a registered trademark of American National Standards Institute, Inc.
Centronics is a registered trademark of Genicom Corporation.
DEC is a registered trademark of Digital Equipment Corporation.
DG/UX is a registered trademark of Data General Corporation.
EIA is a registered trademark of the Electronic Industries Association. ENERGY STAR is a registered trademark of the United States Environmental Protection Agency. As an ENERGY STAR® Partner, Hewlett- Packard has determined that this product meets the ENERGY STAR®
guidelines for energy efficiency.
Epson is a registered trademark of Seiko Epson Corporation.
Ethernet is a trademark of Xerox Corporation.
Frontier Technologies and SuperTCP are trademarks or registered trademarks of Frontier Technologies Corporation.
FTP Software and OnNet are trademarks or registered trademarks of FTP Software, Inc.
IGP, PGL, LinePrinter Plus, Network Interface Card (NIC) and Printronix are registered trademarks, and RibbonMinder is a trademark of Printronix, Inc.
IRIX is a registered trademark of Silicon Graphics, Inc.
LINUX is a registered trademark of Linus Torvalds.
Magnum and QMS are registered trademarks, and Code V is a trademark of Quality Micro Systems, Inc.
Microsoft, MS, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation.
PKZIP and PKUNZIP are registered trademarks of PKWARE, Inc.
NetManage and Chameleon are trademarks or registered trademarks of NetManage, Inc.
Netscape and Netscape Navigator are registered trademarks, and the Netscape Communications logo is a trademark of Netscape Communications Corporation.

Novell and NetWare are registered trademarks of Novell, Inc.
PostScript is a registered trademark of Adobe Systems Inc.
Solaris is a registered trademark of Sun Microsystems, Inc.
Ultrix is a registered trademark of Digital Equipment Corporation.
Unix is a registered trademark of X/Open Company Limited.
This product uses Intellifont Scalable typefaces and Intellifont technology. Intellifont is a registered trademark of Agfa Division, Miles Incorporated (Agfa).
CG, Garth Graphic, Intellifont, and Type Director are registered trademarks, and Shannon and CG Triumvirate are trademarks of Agfa Division, Miles Incorporated (Agfa). CG Bodoni, CG Century Schoolbook, CG Goudy Old Style, CG Melliza, Microstyle, CG Omega, and CG Palacio are products of Agfa Corporation. CG Times, based on Times New Roman under license from The Monotype Corporation Plc is a product of Agfa.
Univers is a registered trademark of Linotype AG and/or its subsidiaries.
Letraset is a registered trademark, and Aachen, Revue and University Roman are trademarks of Esselte Pendaflex Corporation.
Futura is a registered trademark of Fundición Tipográfica Neufville, S.A.
ITC Avant Garde Gothic, ITC Benguiat, ITC Bookman, ITC Century, ITC Cheltenham, ITC Clearface, ITC Galliard, ITC Korinna, ITC Lubalin Graph, ITC Souvenir, ITC Tiepolo, ITC Zapf Chancery, and ITC Zapf Dingbats are registered trademarks of International Typeface Corporation.
Albertus, Gill Sans, and Times New Roman are registered trademarks, and Monotype Baskerville is a trademark of The Monotype Corporation Plc, registered in the U.S. Pat. and TM office and elsewhere.
Hiroshige and Marigold are trademarks of AlphaOmega Typography, Inc.









About This Manual
This manual explains how to configure and perform routine service on the Printronix® P5000LJ Series printers for maximum efficiency.
Read and comply with all information highlighted under special headings:


The Printronix P5000LJ Series Printer Family
The P5000LJ series of line matrix printers consists of 500, 1000, and 1500 lines per minute (lpm) models packaged in various configurations. All of the models offer software versatility and the latest refinements in line matrix printing technology. The model numbers indicate printing speed and physical configuration:
Table 1. The P5000LJ Series Printer Family
Nameplate Print Speed Pedestal Cabinet
C3201D C3201E 500P 500 lpm
C3201ND C3201NE 500P 500 lpm
C3202D C3202E 500Q 500 lpm
C3202ND C3202NE 500Q 500 lpm
C3203D C3203E 1000P 1000 lpm
C3203ND C3203NE 1000P 1000 lpm
C3204D C3204E 1000Q 1000 lpm
C3204ND C3204NE 1000Q 1000 lpm
C3205D C3205E 1500Q 1500 lpm
C3205ND C3205NE 1500Q 1500 lpm
C3206D C3206E 1500P 1500 lpm
C3206ND C3206NE 1500P 1500 lpm
C5640D C5640E 1500QS 1500 lpm
C5640ND C5640NE 1500QS 1500 lpm
Most line matrix printers have specialized architectures which enable the printer to emulate, or behave like, another printer. These specialized architectures are restricted. The P5000LJ printer, however, introduces an open architecture concept that is not available on any other line matrix printer.
The P5000LJ printer offers the standard emulation of Hewlett-Packard's Printer Control Language, PCL Level II, to allow easy online programming capabilities and compatibility with Hewlett-Packard systems. The Printronix P5000LJ Series printers are fully compatible with HP LineJet and LP Series printers.


Additionally, the P5000LJ printer offers the following three emulations as part of its LinePrinter Plus grouping: Proprinter® III XL, Epson® FX-1050, and Serial Matrix P-Series. No matter what emulation is configured, your printer is very easy to use. The message display and indicator on the control panel communicate with you directly and clearly. You can select every function on your printer at the control panel, or you can send commands from the host computer.

Figure 1. The P5000LJ Printers

Taking Care Of Your Printer
Your printer will produce high quality print jobs if it is well taken care of. Periodic cleaning, handling the printer properly, and using the correct printer supplies, such as paper and ribbons, will ensure optimum performance. Chapter 16 explains how to clean the printer, and printer supplies are listed in Appendix A.
All of the printers offer a wide range of horizontal and vertical dot densities, operate quietly, and can load an emulation very easily. Other features are specified in the following sections.
The following host computer interface choices are available: • Bi-Tronics®
Each emulation provides a different set of configuration menus, control codes, and character sets.

Output Control
Depending on the active emulation, the printers have the following output control features: • Four modes for printing text:
Several graphics and vertical formatting features are available: • Built-in graphics generators:

The PGL and VGL emulations allow you to create and store forms; generate logos, bar codes, and expanded characters; and create other graphics. Alphanumerics and bar code data are added as the form is printed.
A protocol is a set of rules governing the exchange of information between the printer and its host computer. These rules consist of codes which manipulate and print data and allow for machine-to-machine communication. A printer and its host computer must use the same protocol.
Most impact printers use single ASCII character codes to print text, numbers, and punctuation marks. Some characters, both singularly and in groups of two or more, are defined as control codes. Control codes instruct the printer to perform specific functions, such as underlining text, printing subscripts, setting page margins, etc. The main difference between most printer protocols is in the characters used to create control codes and the ways in which these characters are formatted.
When the printer executes the character and control codes of a particular printer protocol, it is “emulating” that printer. For example, if the printer uses the Proprinter III XL protocol, it is emulating an IBM Proprinter III XL printer; if the printer is using the Epson FX-1050 printer protocol, it is in Epson FX-1050 emulation mode. As used in this manual, “protocol” and “emulation” mean the same thing.
Graphics Options

Line Matrix Printing
Your printer is an impact printer; it creates characters by printing ink dots on paper. The dots are printed on an invisible matrix mapped in printer memory (see Figure 2). Dot impressions are made by an array of steel hammers mounted on a rapidly oscillating shuttle. The hammers strike the paper through a moving ink ribbon.
Matrix visible only to the printer
Ink dots formed by hammer tips.
Figure 2. Dot Matrix Character Formation
Serial matrix printers use a moving printhead with pins to form single characters sequentially along the printed line. Unlike serial matrix printers, the P5000LJ printer is a line matrix printer. Line matrix printers divide every printable line into horizontal dot rows, then print a dot row of the entire line at every lateral sweep of the shuttle.
During each sweep, hammers are activated to print dots at the required positions in the dot row. When the shuttle reaches the end of a sweep, it reverses direction, the paper advances one dot row, and the hammers print the next row of dots as the shuttle sweeps in the opposite direction, as shown in Figure 3.
After a line of characters is printed, the paper advances to the first dot row of the next print line. This creates a number of blank rows between lines of characters, depending on the print mode and line spacing you selected.


1 2 3 4 5 6 7 8 9 10 11 n 1 2
This row is used for underlining and lowercase descenders.
Figure 3. Dot Matrix Line Printing
The speed at which text prints is measured in lines per minute (lpm). This speed is directly proportional to the number of dot rows required to produce a character line, regardless of the number of characters in the line. More dot rows are required to print lowercase characters with descenders; consequently, those character lines print at a fractionally lower rate.
The printer also prints dot-addressable graphic images. The speed at which graphics are plotted is measured in inches per minute (ipm). Unidirectional plotting produces slightly better print quality and takes about twice as long as bidirectional plotting. You can select either plotting mode from the control panel.
Printing and plotting rates also vary according to the print mode you select. Print mode refers to the way you instruct the printer to create characters. If, for example, you select standard quality (data processing) mode, the printer uses more dot rows to form characters than if you choose Sparse (high speed) mode. Character formation and print speed are faster in Sparse mode, because the printer prints fewer dot rows to form characters. Vertical dot density is a factor in printing speed.
Nominal printing rates are charted in Appendix A.
Printing Speed

Network Interface Card (NIC)
Network Interface Card (NIC) allows you to attach printers on a local area network (LAN) rather than attaching them directly to a host system. Following simple configuration steps, these peripherals can be simultaneously shared with users on the network whether you are using TCP/IP, NetBIOS over TCP/ IP, or IPX (Novell).
NIC contains a network interface card to attach itself and the printer to the network. This Ethernet™ 10/100Base-T interface connector is what allows the printer to communicate with the network, and the interface itself has a number of options, status indicators, and switches which are described in “NIC” on page 27.

NIC
The NIC at the rear of the printer has two indicator lights and two dipswitches, as shown in Figure 4.

1 2 Shown in OFF (default) position
STAT (System Status) NET (Data to Network)
Figure 4. Status Indicator Lights and Dipswitches
Run Mode is the normal operating state of NIC. Auto Reset mode is entered when the watchdog timer is triggered and the Print Server resets itself. In either mode, the STAT LED flashes at a varying rate, depending on whether the unit IP address is configured. The Run Mode and Auto Reset Mode indicator descriptions are given in Table 2.
Table 2. Indicator Modes

OFF flashes on once per second Normal Mode, IP address configured
OFF flashes on twice per second IP address not configured
Dipswitches

Network Indicator
The NET LED displays the status of the network link. When the NET LED is on, link integrity is confirmed. The NET LED flashes off for 1/3 second when a data packet is being transferred. When the NET LED is off, the network connection has been severed.
On the back of the interface, you will find a small window where you can access two dipswitches labeled 1 and 2 (see Figure 4). The functions of the dipswitches are explained in Table 3.
Table 3. Dipswitch Functions
OFF OFF Normal operation. With both dipswitches in the OFF position, the NIC boots up using the settings in flash memory rather than the default settings.
ON OFF Factory default settings. With the dipswitches in this configuration, the NIC boots up and erases all settings stored in flash memory except the Ethernet address and key value.
OFF ON Default IP. With the dipswitches in this configuration, the NIC boots up with factory default settings. However, the stored settings in flash memory are intact. Setting dipswitch 2 to ON does not clear any settings stored in flash memory; instead, it boots the unit with the IP settings in flash memory temporarily ignored.
ON ON Reserved. This dipswitch setting is not for customer use.
Dipswitch · Comments 1 2

Introduction
Downloading the function code is equivalent to updating firmware in the printer. This chapter explains how to load function code into P5000LJ printers.
Updating the function code in a P5000LJ printer consists of three tasks:

Preparation For Downloading
There are several function code files available for the P5000LJ printers. The file you use depends on the printer emulation in use.
To verify what function code is already installed, observe the control panel display when the printer is online. If a configuration printout is available, the function code file version is printed at the top of the configuration printout on the line that begins “Program File Version.” For example, if the line is “Program File Version (2.07P Part No. 356351), the number “356351” is the function code download file active at the time the configuration printout was generated.
You can download function code from a networked PC or laptop computer which contains the function code. If the printer has the NIC installed, the function code must be updated via the network to successfully update the NIC firmware. Loading function code via the network is done using the Printronix Remote Management (RMS) software available on the PrintNet Enterprise CD or using the file transfer protocol (ftp) procedure.

Table 4. P5000LJ Series Printers Function Code Chart
Description Control Panel Displays:
If Serial or Parallel Connected
Printers using PCL-II emulation
ONLINE-PARL / PCL II* (or) ONLINE-PARL / LP PLUS*
xxxxxx.exe (Note 2)
Parallel or Serial Port
4 MB Flash 4 MB DRAM
Printers using VGL emulation
ONLINE-PARL / PCL II / VGL* xxxxxx.exe (Note 2)
Parallel or Serial Port
4 MB Flash 4 MB DRAM
Printers using PGL emulation
ONLINE-PARL/LP PLUS/PGL* xxxxxx.exe (Note 2)
Parallel or Serial Port
4 MB Flash 4 MB DRAM
Printers using PCL-II emulation
ONLINE-ETHERNET / PCL II (or) ONLINE-ETHERNET / LP+
xxxxxx.exe (Note 2)
Via Network (Note 1)
4 MB Flash 4 MB DRAM
Printers using VGL emulation
ONLINE-ETHERNET / LP+ (or) ONLINE-E-NET / CODE V / PCL
xxxxxx.exe (Note 2)
Via Network (Note 1)
4 MB Flash 4 MB DRAM
Printers using PGL emulation
xxxxxx.exe (Note 2)
Via Network (Note 1)
4 MB Flash 4 MB DRAM
* ONLINE - SERL / PCL II or ONLINE - SERL / LP PLUS if serial port is the selected host interface
1 If the internal network card is not installed or was removed, download via the parallel or serial port. If the printer Function Code is downloaded with the NIC removed, or a NIC card is added to the printer after downloading, the Ethernet port will not function with RMS. In this case, do the following: 1. Press the up/down/right/left arrow keys simultaneously. Printer displays “FACTORY / Printer Management.” 2. Press the down arrow key. Printer displays “Diagnostic Port.” 3. Press the down arrow key. Printer displays “Debug Serial.” 4. Press the right arrow key. Printer displays “Debug Ethernet.” 5. Press ENTER. Printer displays “Debug Ethernet*.” Press ONLINE to exit.
2 Check with Technical Support, (Customer Service Center) to confirm the latest available Function Code download file.
In order to download function code to a printer if using a serial or parallel port, the function code file must reside in a PC or laptop computer running any of the following operating systems: MS-DOS®, PC-DOS™, or DOS session on Windows 95/98, Windows NT or Windows 2000.

Loading Function Code To Flash Memory In The Printer
Emulation and operating system software are stored on a CD. You will copy the appropriate file to your computer’s hard disk, then download that file to the printer.You can load software through the serial, parallel, or Ethernet NIC port of the printer:

Downloading Software Through the Serial or Parallel Port

RS232-9600 (RS-232 serial, 9600 baud) RS232-19.2K (RS-232 serial, 19200 baud) RS232-38.4K (RS-232 serial, 38400 baud) RS232-115K (RS-232 serial, 115000 baud) RS422-9600 (RS-422 serial, 9600 baud) RS422-19.2 (RS-422 serial, 19200 baud) RS422-38.4K (RS-422 serial, 38400 baud) RS422-115K (RS-422 serial, 115000 baud) DEBUG

Figure 5. Navigating to the Appropriate Emulation File on the CD

Downloading Software Through the Serial or Parallel Port
This is the file you will download into the printer.

Figure 6. Copying the Emulation File to the Download Directory

The 9600 baud rate is the only selection older versions of MS-DOS can use. The baud rate information entered in the following commands must match the selection you made in step 13.
If you are loading the file through the printer serial port, enter the following commands: mode COM1:9600,N,8,1,P filename.exe -pbc1
While the file is copied into memory, the printer LCD informs you of the load process and status.
Using the configuration printout(s) you made in step 1., reconfigure the printer and reload any optional font files.

Downloading Software Through the Network Interface Card (NIC)

Figure 7. Navigating to the Appropriate Emulation File on the CD

C: cd \download
ftp xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx represents the IP Address of the printer.)
You are given a password prompt.
cd dest cd d1prn bin put filename.prg (where filename.prg is the file name you noted in step 9.)
root · quit

Downloading Optional Font Files to Flash Memory
Optional font files are stored on a 3.5 inch floppy diskette that contains file names comprised of a part number with a .dwn extension. You will insert the diskette in your IBM-compatible computer and use either the parallel or serial port to download the desired font file(s) to the printer’s flash memory.

RS232-9600 (RS-232 serial, 9600 baud) RS232-9600 (RS-232 serial, 19200 baud) RS232-9600 (RS-232 serial, 38400 baud) RS232-9600 (RS-232 serial, 115000 baud) RS422-9600 (RS422 serial, 9600 baud) RS422-9600 (RS422 serial, 19200 baud) RS422-9600 (RS422 serial, 38400 baud) RS422-9600 (RS422 serial, 115000 baud) DEBUG
A: (if the diskette is in drive B, type B:)
You will see a directory listing containing files with a .dwn extension, e.g., 94021.dwn, 94022.dwn, 94023.dwn.
copy /b filename.dwn LPT1 (where filename.dwn is file name you noted in step 14.)
dir

Downloading Optional Font Files to Flash Memory
copy /b filename.dwn LPT2 (where filename.dwn is a file you noted in step 14.)
If you are loading the file using the serial port on the computer, type the following commands:
mode COM1:9600,N,8,1,P copy /b filename.dwn COM1 (where filename.dwn is a file you noted in step 14.)
The 9600 baud rate is the only selection older versions of MS-DOS can use. The baud rate information entered in the above commands must match the selection you made in step 8.
You can download the optional font files one at a time by entering one file name per the copy command or you can copy multiple files in one copy command.
To download one file at a time, enter the following at the command prompt:
copy /b filename.dwn LPT1
To download multiple files, enter the following at the command prompt, for example:
copy /b filename1.dwn+filename2.dwn+...LPT1
a. Perform a configuration printout.
b. Select MAINT/MISCFile SystemsView Files List. The new file names will appear with the same part number file name you downloaded, but with an .sf extension.

Table 5. Flash Memory Message Guide
Message Explanation Required Action
The program successfully loaded into printer RAM and the checksum matched. The old program is now being deleted from flash memory.
DIAGNOSTIC PASSED The printer passed its memory and hardware initialization tests.
Printer cannot find the data controller program or the validation checksum is corrupt.
The printer found a defective memory location.
Replace the DRAM.
Printer cannot find the engine controller program or the validation checksum is corrupt.
Hardware fault in the engine controller.
Replace the CMX controller board.
The printer could not find any flash memory.
The printer could not find any flash memory.
Install flash memory before attempting to download this program.
The printer could not find any DRAM.
Check DRAM on CMX. If present, reseat DRAM, If missing, install DRAM.
ERROR: NVRAM FAILURE The non-volatile memory has failed.
Replace the CMX controller board. (Do NOT attempt to replace NVRAM.)
The printer requires more DRAM memory in order to run the downloaded program.
Add DRAM or use a smaller emulation program.
None · None

Downloading Optional Font Files to Flash Memory
Table 5. Flash Memory Message Guide (continued)
Message Explanation Required Action
The printer requires more flash memory in order to run the downloaded program.
Add flash memory or use a smaller emulation program.
The printer is not compatible with the downloaded program.
Use the correct emulation software option(s) for this model.
The printer does not see a program in flash memory.
There is no program in printer memory. Download the program again.
The security PAL is not present or has failed.
Check the security PAL at location U54 on the CMX controller. If the PAL is absent, install correct PAL. If security PAL is present, replace the CMX controller board.
Hardware failure in DRAM or CMX controller circuitry.
Replace DRAM. If message occurs with new DRAM, replace CMX controller board.
Hardware or software fault in flash memory.
The printer received the complete program but the checksum did not match. The data were corrupted during download.
Download the program again.
An interim message that displays while the printer discards host data it cannot use because a fault condition exists. While this message displays, the asterisk (*) rotates.
Wait. When the asterisk (*) stops rotating, a different fault message will appear: troubleshoot the final message.
The new program is loading into printer RAM. XX indicates how much of the program has loaded.
None

Table 5. Flash Memory Message Guide (continued)
Message Explanation Required Action
The printer has deleted the previous program from flash memory and is loading the new program into flash memory.
The printer finished loading the program into flash memory and is automatically resetting itself.
RESTORING BOOT CODE Normal download initialization message.
The software running or being downloaded does not match the security PAL code.
Install the correct PAL or program. (PAL and program must match.)
The printer is loading the engine controller program into the engine controller.
EC software update in process.
Download the program again.

Overview
This chapter is a tutorial that explains how to configure the P5000LJ printer and the NIC.
In order to print data, the printer must respond correctly to signals and commands received from the host computer. Configuration is the process of matching the printer's operating characteristics to those of the host computer and to specific tasks, such as printing labels, or printing on different sizes of paper.
The characteristics that define the printer's response to signals and commands received from the host computer are called configuration parameters.
A configuration consists of all the parameters under the Active Emulation, Emulation, Maint/Misc., Host Interface, Printer Control, and Diagnostics menus. Chapter 4 describes the configuration submenus and their parameters in more detail.
You configure the printer by pressing keys on the control panel (Figure 8) or by sending control codes from the host computer. This chapter explains how to change parameters and save, print, and load configurations with the control panel. All of the keys are described in detail in the P5000LJ Series Printers Quick Reference Guide which is shipped with each printer.




Secondary Keys (Raise the printer cover to access these keys.)
Figure 8. The Control Panels

CONFIG. CONTROL
ACTIVE EMULATION 1
EMULATION
MAINT/MISC
HOST INTERFACE
Load Config. Save Config. Print Config. Delete Config. Power-Up Config. Protect Configs.
PCL-II* LP PLUS IGP/PGL & LP+ IGP/VGL & LP+
Hex Dump Mode Power-up State Display Language Power Stacker3
Bi-Tronics* Centronics Serial Ethernet3
IGP/VGL & LP+ 3
ETHERNET
PRINTER CONTROL
DIAGNOSTICS
RIBBON MINDER page 132
IP Address Gateway Address Subnet Mask MAC Address Novell Protocol NetBIOS Protocol Novell Frame PPM Port Number PPM Port Timeout Ethernet Speed
Unidirectional PMD Fault Slow Paper Slew Power Saver Time
Printer Tests Test Width Paper Out Dots System Memory Print Statistics
New Ribbon Ribbon Action Ribbon Size Ribbon Adjust Fault Action
Up Next Prev
1 Choices available are limited to the emulations installed on the printer.
To select an option, press ENTER.
2 Appears only if LP Plus is the active emulation.
To return to main menu, press CLEAR.
3 Appears only if installed.
To exit menu, press ON LINE.
* = Default Setting
Figure 9. Configuration Menu Overview

Operating Modes
The printer has two operating modes: online and offline. When the printer is online, it is controlled by the host computer and prints data sent by the host computer. When the printer is offline, communication with the host is interrupted so you can load paper, change ribbons, or test and configure the printer.
Activate configuration settings with the ENTER key, which enters your new setting into printer memory. An asterisk (*) after a displayed setting shows it is entered into memory.
If pressing ENTER to select a parameter produces no result, press DOWN to move to the next lower level. For example, if you press ENTER while CONFIG. CONTROL/ Print Config. displays, nothing will happen because another level exists below this selection. Press DOWN and the “Current” option displays. To cycle through the choices (Current, Factory, Power-Up, etc.), press the NEXT or PREV keys. Press ENTER and the selected configuration will print.
To make configuration changes, you must unlock the ENTER key. With the printer offline, raise the printer cover and press the UP and DOWN keys simultaneously. The LCD will show this message for about a second:
When you lock the ENTER key, your configuration settings are fixed and cannot be altered. (Locking secures your settings.)
With the printer offline, raise the printer cover and press the UP and DOWN keys simultaneously to lock the ENTER key. The LCD will briefly show this message:

Changing And Saving Parameter Settings
You can change a parameter setting, such as line spacing or forms length, by pressing keys on the control panel or by sending emulation control codes in the host data stream.
When you change a parameter, it is active as long as the printer is on. This is true whether you used the control panel or sent a control code from the host.
If you use the control panel, you can save the parameters as a customized configuration. A configuration consists of a group of parameters. A saved configuration will not be lost if you turn off the printer.
You can change a parameter with a control code, but to save the parameter setting you must use the control panel.
Control codes override control panel parameters. For example, if you set the line spacing to 6 lpi with the control panel, and application software later changes this to 8 lpi with a control code, the control code setting overrides the control panel setting.
The 8 lpi parameter is effective as long as the printer is on. If you turn off the printer, the 8 lpi parameter will be erased. To save the parameter, you must use the control panel and save it as a configuration.
You can save up to eight configurations.
Changing parameters is described on page 54, and saving configurations is described on page 56.

Factory Default Configuration Values
The factory default values are permanently stored in memory as a configuration and cannot be modified or erased. The configuration values for the Bi-Tronics parallel interface and NIC interface are displayed on the following pages.
ACTIVE EMULATION PCL-II PCL-II
Primary Char. set
ID 0 Symbol Set Roman-8 [8U] Pitch 10.00 Density Data Processing Second Char. set
ID 0 Symbol Set Roman-8 [8U] Pitch 10.00 Density Data Processing Page Length Rep. Inches/Page Max. Line Width 13.2 inches Face, CPI Delay Enable Graphics Density 60 DPI Perforation Skip Disable Display Functns Disable Line Terminator
LF After CR Disable CR After LF Disable CR after FF Disable CR After VT Enable PTX Linefeed Disable LPI Adjust 6 LPI Page L./Lines 66 Lines Page L./Inches 11.0 Inches Config. Print Symbol Set Print Reset Cmd CFG Ld Power Up Config LP PLUS
Control Code 06 8.0 LPI Control Code 08 Elongated Define CR Code CR = CR Auto LF Disable Overstrike Enable Define LF code LF = CR + LF Select SFCC 1 EVFU Select Enable Alt. Set 80-9F Control Code Character Set
Primary Subset ASCII (USA) Extended Subset Code Page 437 SFCC d command Even dot plot CPI/LPI Select
Select CPI 10.0 CPI Select LPI 6.0 LPI
Printer Protocol · P-Series

Factory Default Configuration Values
Typeface Data Processing Prop. Spacing Disable Bold Print Disable Italic Print Disable Slashed Zero Disable Page Format
Abs. Length IN 11.0 inches Abs. Length MM 279.4 mm Funct. of lines 66 lines Form Width
Abs. Width IN 13.6 inches Abs. Width MM 345.4 mm Function of CPI 136 characters Margins
Left Margin 0 columns Right Margin 0 columns Bottom Margin 0 lines Perforation Skip Disable MAINT / MISC
Hex Dump Mode Disable Power-up State Online Display Language English Power Stacker Enable HOST INTERFACE
Prime Signal Disable TOF Action Reset Buffer Size in K 1 PRINTER CONTROL
Unidirectional Disable PMD Fault Enable Slow Paper Slew Disable Power Saver Time 15 min DIAGNOSTICS
Printer Tests Shift Recycle Test Width Full Width Paper Out Dots 40 dots System Memory x Megabytes Print Statistics
On: x.x Hrs Print: x.x Hrs Print Strokes x Print Lines x 11 inch Pages x RIBBONMINDER
New Ribbon Ribbon Action Disable Ribbon Size 60 yards Ribbon Adjust 0 Fault Action New Ribbon
Font Attributes · Form Length · Bi-Tronics

NIC Interface
ACTIVE EMULATION PCL-II PCL-II
Primary Char. set
ID 0 Symbol Set Roman-8 [8U] Pitch 10.00 Density Data Processing Second Char. set
ID 0 Symbol Set Roman-8 [8U] Pitch 10.00 Density Data Processing Page Length Rep. Inches/Page Max. Line Width 13.2 inches Face, CPI Delay Enable Graphics Density 60 DPI Perforation Skip Disable Display Functns Disable Line Terminator
LF After CR Disable CR After LF Disable CR after FF Disable CR After VT Enable PTX Linefeed Disable LPI Adjust 6 LPI Page L./Lines 66 Lines Page L./Inches 11.0 Inches Config. Print Symbol Set Print Reset Cmd CFG Ld Power Up Config LP PLUS
Control Code 06 8.0 LPI Control Code 08 Elongated Define CR Code CR = CR Auto LF Disable Overstrike Enable Define LF code LF = CR + LF Select SFCC 1 EVFU Select Enable Alt. Set 80-9F Control Code Character Set
Primary Subset ASCII (USA) Extended Subset Code Page 437 SFCC d command Even dot plot CPI/LPI Select
Select CPI 10.0 CPI Select LPI 6.0 LPI Font Attributes
Typeface Data Processing Prop. Spacing Disable Bold Print Disable Italic Print Disable Slashed Zero Disable
Printer Protocol · P-Series

Factory Default Configuration Values
Abs. Length IN 11.0 inches Abs. Length MM 279.4 mm Funct. of lines 66 lines Form Width
Abs. Width IN 13.6 inches Abs. Width MM 345.4 mm Function of CPI 136 characters Margins
Left Margin 0 columns Right Margin 0 columns Bottom Margin 0 lines Perforation Skip Disable MAINT / MISC
Hex Dump Mode Disable Power-up State Online Display Language English Power Stacker Enable HOST INTERFACE
Buffer Size in K 1 ETHERNET PARAMS
IP Address xxx.xxx.xxx.xxx Gateway Address xxx.xxx.xxx.xxx Subnet Mask xxx.xxx.xxx.xxx MAC Address hhhhhhhhhhhh Novell Protocol Disable NetBIOS Protocol Disable Novell Frame Ethernet 802.2 PPM Port Number 3001 PPM Port Timeout 100 seconds Ethernet Speed Auto Select PRINTER CONTROL
Unidirectional Disable PMD Fault Enable Slow Paper Slew Disable Power Saver Time 15 min DIAGNOSTICS
Printer Tests Shift Recycle Test Width Full Width Paper Out Dots 40 dots System Memory x Megabytes Print Statistics
On: x.x Hrs Print: x.x Hrs Print Strokes x Print Lines x 11 inch Pages x RIBBONMINDER
New Ribbon Ribbon Action Disable Ribbon Size 60 yards Ribbon Adjust 0 Fault Action New Ribbon
Page Format · Form Length · Ethernet

Changing Parameters
A configuration consists of several parameters. The factory configuration is PCL-II emulation using the Bi-Tronics interface. You can keep this configuration to print your jobs, or if your print job requires a different setting such as a serial interface, follow the procedure outlined in Table 6.
The example below describes how to change the Unidirectional parameter from disable to enable. Use this example as a basic guideline to move throughout the configuration menu and change other parameters.
Figure 9 on page 47 shows the top level of the configuration menu. The submenus are shown in Chapter 4.
If the configuration has already been changed and you do not know what the current configuration is, print a copy (page 58). Then decide if you must change any parameters.
* = Factory Default
CONFIG. CONTROL
PRINTER CONTROL
Unidirectional PMD Fault Slow Paper
15* - 60 Min. Instant
Table 6. Parameter Change Example Procedure
Step Key Result Notes
OFFLINE CONFIG. CONTROL

Table 6. Parameter Change Example Procedure (continued)

TO SAVE YOUR CHANGES AS A CONFIGURATION THAT IS STORED IN MEMORY:
Example

Saving Your New Configuration
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
1 2 3 4 5 6 7 8
A configuration must be saved in order to load it later. You can save up to eight configurations to meet different print job requirements. For example:
The configurations are saved and stored in memory; they will not be lost if you power off the printer. Later, you can load one of the configurations for a specific print job. This eliminates the need to change settings (LPI, forms length, etc.) for each new job. See page 60 for information about loading configurations. You may want to print your configurations (page 58) and store them in a safe place, such as inside the printer cabinet.
If you are going to change and save parameters for both the PCL-II and LinePrinter Plus emulations, remember to save the changes for the PCL-II emulation before you select LP Plus as the active emulation (page 79) or vice versa. Once you change active emulations, any changes to the previously selected emulation will be erased unless they have been saved.
If you do not save your configuration before you turn off the printer, all of the new parameters will be erased. When you turn the printer on again, the power-up configuration will load. If no configurations have been designated as the power-up configuration, the factory configuration will load.
If the Protect Configs. parameter is enabled, the new configuration will not be saved unless the existing configuration has been deleted. See page 66 for details.

Saving Your New Configuration
Table 7. Saving Configurations

decide not to print the configuration, then continue with the following steps.

Printing The Current Configuration
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
Current* Factory Power-Up All 1 2 3 4 5 6 7 8
The configuration printout lists the stored parameters. You can print any or all of the configurations shown above. Configurations 1-8 are the customized configurations.
To print a configuration, follow the procedure in Table 8.

Printing The Current Configuration
Table 8. Printing Configurations


Loading Configuration Values
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
0* 1 2 3 4 5 6 7 8
You can load any of the eight customized configurations or the factory default configuration, Configuration 0. Its list of parameters begins on page 50.
The loaded configuration remains active as long as the printer is on. If you power off the printer, the power-up configuration will load when power is turned back on. Any of the eight customized configurations can be designated as the power-up configuration.
The procedure in Table 10 explains how to select the power-up configuration. If you do not set a power-up configuration, the factory default configuration will load if you power the printer off and then power it back on.

Table 9. Loading Configurations

Loading Configuration Values

The Power-Up Configuration
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
0* 1 2 3 4 5 6 7 8
When you power on the printer for the first time, it loads configuration 0 which is the factory default configuration.
If you save a configuration, such as configuration 1, and turn the power off and then back on, the printer will load the designated power-up configuration, not the last saved configuration.
For your convenience, you can specify which configuration (0-8) should be the power-up configuration.

Table 10. Setting The Power-Up Configuration

The Power-Up Configuration

Deleting Configurations
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
1* 2 3 4 5 6 7 8
You can delete any of your customized configurations. You cannot, however, delete the configuration 0, which is the factory preset configuration.
The Protect Configs. parameter must be set to disable before you may delete a configuration (see page 66).

Table 11. Deleting Configurations

Deleting Configurations

Protecting Your Configurations
* = Factory Default
Load Config. Save Config. Print Config. Delete Config. Power-Up
Protect Configs.
Config.
To save or delete a configuration you must set the Protect Configs. option to disable.
Disable* Enable

Connecting To The Network
To attach the NIC to a network, plug the network cable into the NIC connector (see Figure 10).
Watch the LEDs in the rear of the printer as they cycle through the power on self-test. When the test is complete, the STAT led will flash.


Figure 10. Physical Setup
There are two parts to a NIC setup:
Network Connector

NIC settings can be set from the printer control panel. The procedure is described below.
Note When the printer is first powered on, the messages “Waiting for the Ethernet Adapter” and “Ethernet Detected” will display on the LCD. After several other boot messages appear, the LCD will display the message “E-NET INIT.” This initialization process will take about two minutes. During that time, you will not be able to change any printer settings from the control panel. If you attempt to do so, the message “Please Wait E-NET INIT.” will appear. When the initialization is complete, the message “E-NET READY” will display, and you may then change any NIC or other printer configuration options from the control panel.
The procedure for changing any of the parameters is the same. The procedure for changing the IP Address is given here as an example. Use the same procedure for the other required parameters.
To change the IP Address parameter:

Caution When a change is made from the control panel, the NIC is re- initialized. The messages “E-NET RESET” and “E-NET INIT” display on the control panel. This process takes several minutes. Make sure not to shut the printer off or make further changes to the NIC settings during this initialization period to prevent a loss of NIC configuration information. When the initialization is complete, the message “E-NET READY” will display.
Besides the HTML forms and software provided, the NIC internal command shell, npsh, can also be reached using the following methods.
The PPM utility is a versatile and dynamic program. It allows you to remotely organize all the printers in your office in a single database; download software and printer settings from a host computer with a single mouse click; and use a virtual operator's panel to configure printers in the same room or on the other side of the world.
A TCP/IP command that helps configure NIC settings remotely. A TCP/IP host starts a Telnet session with the print server and logs in to the device command shell to alter and view settings.
Configuration Alternatives

Remote Shell
A TCP/IP command that helps configure print server settings remotely. A TCP/IP host uses this command to remotely execute a single command on the NIC.
This command remotely executes the npsh command list prn on the NIC named spike.
NIC settings can be configured over TCP/IP through a standard Web browser. The NIC Web pages provide a handy way to access some of the commands built into the print server. You can access online help for all HTML pages.
To access the NIC home page:


Figure 11. WWW Printer Status Screen
Configuration Alternatives


Overview
Once you have familiarized yourself with the configuration process using the tutorial information in Chapter 3, you are ready to complete your configuration of the printer.
This chapter provides descriptions for each parameter provided by the configuration menus. Figure 12 shows the configuration main menu and its first level parameters. The remainder of this chapter includes illustrations of many additional submenus and parameters nested beneath each of the main menu options.

Configuration Main Menu
OFFLINE
CONFIG. CONTROL (see page 77)
EMULATION (see page 80)
MAINT/MISC (see page 114)
Continued on the next page
Load Config.
PCL-II* LP PLUS IGP/PGL & LP+ IGP/VGL (CODE-V) & LP+
PCL-II* LP PLUS IGP/PGL & LP+ IGP/VGL (CODE-V) & LP+
0* - 8 Save Config.
Disable* Enable Power-up State
1* - 8 Print Config.
Online* Offline Display Language
Current* Factory Power-Up All 1 - 8 Delete Config.
English* Italian French German Spanish Power Stacker2
1* - 8 Power-Up Config.
0* - 8 Protect Configs.
1 Choices available are limited to the emulations configured with the printer. 2 Appears only if the power stacker option is installed.
To select an option, press ENTER.
To return to main menu, press CLEAR.
To exit menu, press ON LINE.
* = Default Setting
Figure 12. Configuration Main Menu

HOST INTERFACE (see page 115)
PRINTER CONTROL (see page 127)
RIBBON MINDER (see page 132)
PARAMS (see page 125)
Serial (cont.)
New Ribbon Ribbon Action
xxx.xxx.xxx.xxx Gateway Address
Disable* Enable PMD Fault
Shift Recycle* All E’s E’s + TOF All H’s All Underlines All Black Shuttle Slow Shuttle Fast Shuttle Only Phase Printer
Disable* Enable TOF Action
Disable* Display Fault Ribbon Size
xxx.xxx.xxx.xxx Subnet Mask
Enable* Disable Open Platen @BOF
Reset* Do Nothing Buffer Size in K
None* Odd Even Mark Sense Data Term Ready
xxx.xxx.xxx.xxx MAC Address
60 yards* (1-255) Ribbon Adjust
Disable* Enable Slow Paper Slew
Enable* Disable NetBIOS Protocol
0%* (-99% to 99%) Fault Action
Disable* Enable Power Saver Time
Enable* Disable PI Ignored
True* On-Line and BNF Off-Line or BF False Request to Send
217* (500 lpm) 123* (1000 lpm) 62* (1500 lpm) (1 to 2000) Paperout Adj. Burnin Test Print Error Log Clear Error Log E-Net Test Page Test Width
Enable* Disable Novell Frame
New Ribbon* Do Nothing
15 min.* (5 sec.-60 min.) Disable Instant
Enable* Disable Data Polarity
Ethernet 802.2* 802.2 Snap Auto Sensing Ethernet II Ethernet 802.3 PPM Port Number
On-Line and BNF* Off-Line or BF False True Buffer Size in K
Standard* Inverted Resp. Polarity
Standard* Inverted Busy on Strobe
3001* (0-65535) PPM Port Timeout
Full Width* 80 col. Paper Out Dots
Enable* Disable Latch Data On
Buffer Size in K
16* (1-16) Auto Switching
32 Seconds* (1-255) Ethernet Speed
40 dots* (4-76 dots) System Memory
Leading* Trailing Prime Signal
Auto Select* 10 Half Duplex 10 Full Duplex 100 Half Duplex 100 Full Duplex
x Megabytes Print Statistics
Bi-Tronics* Centronics Ethernet Disable Trickle Time
Disable* Enable TOF Action
Reset* Do Nothing Buffer Size in K
1/4* (1/4-16 sec.) Off Timeout
10 sec.* (1-60 sec.) Report Status
RS-232* RS-422 Data Protocol
Disable* Enable Serial Hotport
XON / XOFF* ETX / ACK ACK / NAK DTR Baud Rate
RS-232* RS-422 Disable Trickle Time
9600* 19200 38400 600 1200 2400 4800 Word Length
To select an option, press ENTER.
1/4* (1/4-16 sec.) Off Timeout
To return to main menu, press CLEAR.
10 sec.* (1-60 sec.) Report Status
To exit menu, press ON LINE.
* = Default Setting
Figure 12. Configuration Main Menu (continued)


Load Config. Save Config. Print Config. Delete Config. Power-up
Protect Configs.
Config.
0* 1 2 3 4 5 6 7 8
1* 2 3 4 5 6 7 8
Current* Factory Power-up All 1 2 3 4 5 6 7 8
1* 2 3 4 5 6 7 8
0* 1 2 3 4 5 6 7 8
To select an option, press ENTER.
To return to main menu, press CLEAR.
To exit menu, press ON LINE.
* = Default Setting
The CONFIG. CONTROL menu manages configurations, which are groupings of parameter values that can be stored in printer memory. Brief descriptions follow for each option.
Load Config.
The printer can store up to eight unique configurations in memory. This parameter allows you to select and load a specific configuration.
Configuration 0 is the factory default, and its parameters cannot be changed. It is always available for loading. See page 60 for a detailed description and sample procedure.
Disable* Enable

Save Config.
This option allows you to save up to eight unique configurations to meet different print job requirements, which eliminates the need to change the parameter settings for each new job.
The configurations are stored in memory. They will not be lost if you turn off the printer. Configuration 0 is a factory-preset configuration, which cannot be changed or saved. See page 56 for a detailed description and sample procedure.
Print Config.
Allows you to print a listing of stored printer configurations. It is recommended you store the configurations in a safe place for quick referral, such as inside the printer, if you have a cabinet model. See page 58 for a detailed description and sample procedure.
Delete Config.
Allows you to delete one or all of your eight customized configurations. Configuration 0 is a factory-preset configuration and cannot be changed or deleted.
Power-Up Config.
Allows you to specify which of the nine configurations (0-8) will be the power- up configuration. The factory default for power-up is configuration 0. See page 62 for a detailed description and sample procedure.
Protect Configs.

PCL-II* LP PLUS IGP/PGL &
IGP/VGL (CODE-V) &
LP+ 1
LP+ 1
When changing from one IGP emulation to the other, the printer will load the power-up configuration. Thus, any setting performed before selecting those emulations and not saved in flash memory will be lost.
For more information on IGP/PGL and Code V, see the appropriate Technical Reference Manual.

Emulation Menu
EMULATION
PCL-II* LP PLUS IGP/PGL &
IGP/VGL (CODE-V) &
LP+ 1
LP+ 1
(see page 81) (see page 86) (see page 102) (see page 107)
To select an option, press ENTER.
To return to main menu, press CLEAR.
To exit menu, press ON LINE.
* = Default Setting 1 = If installed
The EMULATION menu is the gateway to configure the emulations available with the P5000LJ printer. The control codes for each of these emulations are described in their respective Technical Reference Manuals.
Hewlett-Packard's Printer Control Language that is compatible with Hewlett- Packard systems.
IGP/VGL (Code V) and IGP/PGL are optional graphics emulations. They can be selected and configured only if you have purchased these options. PCL-II must be the active emulation for Code V or IGP/PGL to operate.


PCL-II Emulation

Primary Char. set (from previous
Char. Set (from previous
Roman-8[8U]* Turkish-8[8T] Arab-8[8V] Cyrillic[8R] PC858 MtLi[13U] MC Text[12J] Roman-9[4U] Latin-9[9N] Win3.0Lat-1[9U] Japan Postnet Katakana Post ASCII[0U] Math Sym[0A/0M] LineDraw[0B/0L] IS0 Den/Nor[0D] Roman Ext.[0E] IS0 UK[1E] IS0 France[0F] IS0 German[0G]
Hebrew[0H] Japan ASCII[0K] Katakana[1K] Block Char[1L] OCR-A[0O] OCR-B[1O] ISO Swe/Fin[0S] ISO Spain[1S] ISO Italian[0I] ISO Portugu[4S] Latin-1[0N] Latin-2[2N] Latin-5[5N] Latin-6[6N] Baltic[19L] PC8 DanNor[11U] PC8 Cd437[10U] PC850 MtLi[12U] PC851 LtGk[12G]
PC852 Lat2[17U] PC Turkish[9T] PC Hebrew[15H] PC Lat/Ara[10V] PC Cyrillic[3R] Win3.1Lat1[19U] Win3.1Lat-2[9E] Win3.1Lat-5[5T] Math-8[8M] PS Math[5M] Greek-7[12N] Postnet4[15Y] Postnet11.25 Greek-8[8G] Hebrew-8[8H] Katakana-8[8K] DEC 256 Greek ELOT 928 Greek Greek 3
(identical to Primary Character Set) ABY Greek ABG Greek ELOT 927 Greek Greek 437 Greek 8859-7
You can select one of 92 pre-defined character sets by ID (although character sets range from 0 - 109, not all sets are available on the LJ500 printer), or you can select pitch, symbol set, and typeface individually. If the combination you choose matches one of the 92 predefined sets, the ID submenu will reflect that selection. If not, the ID menu will display xx to indicate that the current character set does not match a pre-defined set. Set 0 is the default, and its attributes are 10 cpi, Data Processing typeface, and Roman 8 symbol set.
Your printer can store an additional character set. To toggle between them, send the Shift In (Decimal 15, to select the Primary character set) or Shift Out (Decimal 14, to select the Secondary character set).

For example, if the form in use is 82 lines at 6 lpi, the page is physically 13.67 inches. Since 13.67 inches is not selectable from the Length in Inches menu, change the representation to lines, then set the number of lines to 82. The inches menu will display 13.6 inches although the printer internally keeps the exact form length of 13.67 inches.
Set the maximum line width at 13.2 inches (the default) or 13.6 inches.
Graphics can be printed in 60 DPI (the default) or 70 DPI.
You can specify what will be used to indicate the end of a line. Four options are available: LF after CR, CR after LF, CR after FF, and CR after VT. Each of these options may be enabled or disabled independent of one another.
PCL-II Emulation


PTX Linefeed Enabled PTX Linefeed Disabled
LINE 1
LINE 2
LINE 3
LINE 3
LPI Adjust
This parameter lets you specify the lines per inch (lpi) values: 6 LPI (the default) or 8 LPI.
This parameter lets you set physical page length in lines from 12 to 96 at 6 lpi, or 16 to 128 at 8 cpi. The default is 66 lines at 6 lpi.
This parameter allows you to set physical page length from 2 to 16 inches, in increments of half an inch. The default is 11 inches.
This option prints the emulation's parameters and the currently selected values.
Linefeed · Linefeed LINE 2

This option prints a list of all the available sets. The character set number prints to the left of the character set sample.
When the printer receives a host data stream reset command in addition to resetting printer variables, the selected configuration will be loaded. • Disable.
The printer ignores the reset command when it is received and continues to use the currently loaded configuration. • Power-Up Config.
The power-up configuration is loaded when the reset command is received. • Current Config.
If you have preset and presaved multiple configurations, then the currently selected presaved configuration is loaded when the reset command is received. • Factory Config.
The factory installed configuration is loaded when the reset command is received.
PCL-II Emulation



10.0 CPI* 12.0 CPI 15.0 CPI 17.1 CPI 20.0 CPI Select LPI
Data Processing* NLQ OCR-A OCR-B High Speed NLQ Sans Serif Prop. Spacing
Disable* 1/2 inch 2/3 inch 5/6 inch 1 inch
(see page 90) (see page 93) (see page 95)

Select the LinePrinter+ protocol you wish to use. Refer to the PCL-II/ LinePrinter Plus Technical Reference Manual for more information.
When this selection is displayed and the ENTER key is pressed, the current character set is printed.
This parameter lets you specify the characters per inch (cpi) value and lines per inch (lpi) value.
Typefaces
Each printed character is contained inside a character cell. The width of the character cell includes the character and the space around the character. • Disable. Each character cell is printed with the same width. Each column in the printed text will line up.


LP Plus Emulation

Bold Print
Forms Length
Forms length is the number of lines that can be printed on a page. You can set forms length in inches, millimeters (mm) or as a function of the current LPI (lines per inch).
The forms width can be specified in inches, millimeters, or as a function of the current CPI (characters per inch). The forms width set should not exceed the actual paper width.

When the printer receives a host data stream reset command in addition to resetting printer variables, the selected configuration will be loaded. • Disable.
The printer ignores the reset command when it is received and continues to use the currently loaded configuration. • Power-Up Config.
The power-up configuration is loaded when the reset command is received. • Current Config.
If you have preset and presaved multiple configurations, then the currently selected presaved configuration is loaded when the reset command is received. • Factory Config.
The factory installed configuration is loaded when the reset command is received.
LP Plus Emulation


* = Factory Default
Printer Protocol (from page 86)
Auto LF Overstrike Define LF
CR = CR* CR = CR + LF
LF = CR + LF* LF = LF
Select SFCC EVFU Select Alt. Set 80-9F Character
(see below) Even dot plot* Double high
IBM PC* Multinational ECMA Latin 1 DEC Mult.
ASCII (USA)* EBCDIC
ASCII (USA)* French German English Norw./Danish Swedish Italian Spanish Japanese French Canadian Dutch Finnish Swiss
ASCII (USA)* French German English Danish Swedish Italian Spanish Japanese French Canadian Latin American Danish II Spanish II Latin Am II Extended Subset
ASCII (USA)* German Swedish Danish Norwegian Finnish English Dutch French Spanish Italian Turkish Japanese Extended Subset
Latin 2 8859-2 Latin 2 852 Bulgarian
Polish POL1 DEC 256
Multinational* Barcode 10 CPI Mult. DP 10 CPI Mult. DP 12 CPI Mult. LQ 10 CPI Greek DP 10 CPI Greek DP 12 CPI Greek LQ 10 CPI Grap. DP 10 CPI Grap. LQ 10 CPI Sci. DP 10 CPI Sci. DP 12 CPI Sci. LQ 10 CPI
Code Page 437* Code Page 850
ABY Greek ABG Greek ELOT 927
Greek 8859-7 PC851 LtGk[12G]

Control Code 06 defines the function of ASCII code hex 06 (ACK). You can select an alternate line spacing of 6, 8, or 10.3 LPI.
Control Code 08 defines the function of ASCII code hex 08 (BS). You can define the code to output an elongated character or a backspace.
P-Series Emulation

Select SFCC
Determines whether the printer processes ASCII codes hex 80 through hex 9F as control codes or as printable characters.
Specifies a character set as shown in the character set menu. To use one of these sets, choose the desired group heading (such as Multinational) and press ENTER. Then choose the desired set within that group (such as EBCDIC) and press ENTER. Both the group and the desired set name will include an asterisk to indicate your selection.

* = Factory Default
Printer Protocol (from page 86)
Auto LF Define LF
Alt. Char Set 20 CPI Condensed
CR = CR* CR = CR + LF
LF = LF* LF = CR + LF
Code Page 437* Code Page 850 OCR-A OCR-B Latin 2 8859-2 Latin 2 852 Bulgarian Latin-9 8859-15 Polish POL1 Multinational
Set 1* Set 2
ASCII (USA)* EBCDIC DEC 256 Greek ELOT 928 Greek Greek 3 ABY Greek ABG Greek ELOT 927 Greek Greek 437 Greek 8859-7 PC851 LtGk[12G] Greek-7[12N] Greek-8[8G]

Auto LF
Specifies a character set as shown in the menu. To use one of these sets, choose the desired character set and press ENTER. The desired set will be marked with an asterisk to indicate your selection.

* = Factory Default
Printer Protocol (from page 86)
Auto LF Define LF
Alt. Set 80-9F
LF = LF* LF = CR + LF
ASCII (USA)* French German English Danish I Swedish Italian Spanish I Japanese Norwegian Danish II Spanish II Latin Am I French Canadian Latin Am II OCR-A OCR-B Latin 2 8859-2 Latin 2 852 Cyrillic 866 Bulgarian Latin-9 8859-15 Polish POL1 Multinational
ASCII (USA)* EBCDIC DEC 256 Greek ELOT 928 Greek Greek 3 ABY Greek ABG Greek ELOT 927 Greek Greek 437 Greek 8859-7 PC851 LtGk[12G] Greek-7[12N] Greek-8[8G] IBM PC

Define CR Code
This parameter selects a character set for the Epson emulation, as shown in the Character Set menu. Note that when OCR-A or OCR-B is selected as the print language, the Font Attribute Typeface option under the LinePrinter Plus menu (page 86) is changed to OCR-A or OCR-B, respectively.

* = Factory Default
Printer Protocol (from page 86)
Auto LF Overstrike Define LF
CR = CR* CR = CR + LF
LF = LF* LF = CR + LF
Alt. Set
(see page 99) Even dot plot* Double high
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can select an alternate line spacing of 6, 8, or 10.3 LPI.

Auto LF
Specifies a character set as shown in the “Serial Matrix Character Set Menu” on page 99. To use one of these sets, choose the desired group heading (such as European Sets) and press ENTER. Then choose the desired set within that group (such as Roman 8) and press ENTER. Both the group and the desired set name will include an asterisk to indicate your selection. Character sets are shown in detail in the Character Sets Reference Manual.

* = Factory Default
Character Set (from page 97)
IBM PC* Multinational ECMA Latin 1 DEC Mult.
OCR-A OCR-B Latin 2 8859-2
ASCII (USA)* French German English Norw./Danish Swedish Italian Spanish Japanese French Canadian Dutch Finnish Swiss
ASCII (USA)* French German English Danish Swedish Italian Spanish Japanese French Canadian Latin American Danish II Spanish II Latin Am II Extended Subset
ASCII (USA)* German Swedish Danish Norwegian Finnish English Dutch French Spanish Italian Turkish Japanese Extended Subset
Polish POL1 DEC 256
Multinational* Barcode 10 CPI Mult. DP 10 CPI Mult. DP 12 CPI Mult. LQ 10 CPI Greek DP 10 CPI Greek DP 12 CPI Greek LQ 10 CPI Grap. DP 10 CPI Grap. LQ 10 CPI Sci. DP 10 CPI Sci. DP 12 CPI Sci. LQ 10 CPI
Code Page 437* Code Page 850
Greek 3 ABY Greek ABG Greek
Greek 437 Greek 8859-7

P-Series XQ Emulation
Printer Protocol (from page 86)
* = Factory Default
Auto LF Define LF
Elong/Alt.
CR = CR* CR = CR + LF
LF = CR + LF* LF = LF
char 01 SOH* char 03 ETX char 09 HT
Elng=BS Font=SO* Elng=SO Font=BS
HS Print EVFU Select Upr. Case
char 02 STX* char 03 ETX char 09 HT
1 to 16 lines* 1 to 15 lines
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can select an alternate line spacing of 6, 8, or 10.3 LPI.

P-Series XQ Emulation


“Slewing” is rapid vertical paper movement. This parameter determines the number of lines slewed (either 1-15 lines or 1-16 lines) when an EVFU Slew Relative command is received.
The IGP/PGL emulation can be configured either through the printer’s front panel or from the host computer with control codes. For a detailed description of configuration with control codes, see the PGL Technical Reference Manual. For information on configuring the emulation through the printer’s front panel, see the submenu below and the parameter descriptions that follow.


You can specify which decimal code (1-255) will be used as the Special Function Control Code (SFCC). The factory default setting is 126. The SFCC denotes that the following data is a PGL command.
IGP/PGL Emulation

Select Font
This parameter allows you to select a font for the IGP/PGL feature. The default is 0, which is U.S. ASCII. The following values are valid choices:
0 U.S. ASCII 1 German 2 Swedish 3 Danish 4 Norwegian 5 Finnish 6 English 7 Dutch 8 French 9 Spanish 10 Italian 11 Turkish
Values 12-23 are undefined and will default to 0. You can set values 24-31 to specific fonts; refer to the USET command in the IGP/PGL Technical Reference Manual.
This is the number of lines to be printed per inch. For example, at 6 lpi there is 1/6 inch from the top of one print line to the top of the next print line.

Ignore Mode
Instructs the PGL which decimal character (0-255) to ignore from the host.
IGP/PGL Emulation

IGP100 Compatbl.

IGP/VGL (Code V) Emulation
The IGP/VGL (Code V) emulation can be configured either through the printer’s front panel or from the host computer with control codes. For a detailed description of configuration with control codes, see the QMS Code V Technical Reference Manual. For information on configuring the emulation through the printer’s front panel, see the submenu below and the parameter descriptions that follow.
* = Factory Default
EMULATION (from page 80)
LP+
SFCC &
6* 7 8 9 10
(see next page) Error Msgs
94* (17-255) Ignore Mode
Enable* Disable Error Markers
Disable* Enable Data Bit 8
Disable* Enable Free Format
Enable* Disable Offpage Errors
Disable* Enable Mgnum Conversion
Disable* Enable Barcode Errors
ISO Char Set PI Control
Disable* Enable Host PI
Disable* Enable Max PI 16

* = Factory Default
Options (from page 107)
Ignore Dots Append Rotated
Absorb All* Disable Absorb Motion
Rot. Char
Midline PY Convert to
^PN
IGP110 Compatbl.
This option has several suboptions which define the SFCC and power-up configuration used with Code V.
This option selects the Special Function Control Code. The default value is the caret ^ (decimal 94). Valid values are 17 through 255. Throughout this section, the ^ is used as the SFCC. Run a configuration printout to determine the currently selected SFCC.

IGP/VGL (Code V) Emulation
The number of lines to be printed per inch. For example, at 6 lpi there is 1/6 inch from the top of one print line to the top of the next print line.
Following are several options which configure printing output:

Truncate Alpha
When enabled, this parameter prevents the printing of Error 48 (Element Off Page Error) if alphanumeric data, including spaces, extends beyond the right side of the form.

IGP/VGL (Code V) Emulation
IGP110 Compatbl.
Following are several options which define how errors are reported:
>> for elements that begin off the right side of the page;

Following are several options which define character filtering and data bit 8.
Conversely, when data bit 8 is disabled and the PI signal is used, data bit 8 of the data is reserved for use as the PI function, and you cannot access characters in the hex 80-FF range. Therefore, to access characters in the hex 80-FF range, data bit 8 must be enabled.

IGP/VGL (Code V) Emulation
This parameter allows you to select a font for the IGP/VGL (Code V) feature. The default is 0, which is U.S. ASCII. The following values are valid choices:
0 U.S. ASCII 1 United Kingdom 2 Swedish/Finnish 3 Norwegian/Danish 4 Japanese 5 German 6 French 7 Italian 8 Spanish 9 PC Subset 10 Code V Version I
Printer PI

Maint/Misc Menu
MAINT/MISC
English* Italian French German Spanish
To select an option, press ENTER.
To return to main menu, press CLEAR.
To exit menu, press ON LINE.
* = Default Setting 1 = If installed
A hex code printout (or hex dump) translates all incoming data to hexadecimal equivalents. A hex dump lists each ASCII data character received from the host computer together with its corresponding two-digit hexadecimal code. Hex dumps can be used to troubleshoot some types of printer data reception problems. Figure 23 on page 280 shows a hex dump sample.
This parameter allows you to configure the printer to power-up in the offline or online state. Online is the default.
This parameter chooses the language that will appear on the message display: English, Italian, French, German, or Spanish.

IGP/VGL (Code V) Emulation
This parameter, which is only presented with the 1500QS model, allows you to enable (the default) or disable power stacker operation.
(see page 116) (see page 117) (see page 119)

Note The printer will not work online unless the type of interface selected from the HOST INTERFACE menu matches the type of interface in your host computer. The interface in your host computer is the one that connects to the data cable of the printer. For example, if the interface in your computer is a serial interface, then the serial interface must be selected from the HOST INTERFACE menu in the printer.
The currently selected interface is indicated with an asterisk on the control panel message display. Each interface has its own submenu with the set of associated interface parameters that you may configure. The host interface and its associated parameters control the interface between the printer and your host computer. Descriptions follow for each of the host interface submenus.
* = Factory Default
Bi-Tronics (from page 115)
Prime Signal TOF Action Buffer Size in
Disable* Enable · Reset* Do Nothing · 1* (1-16)

This option configures the amount of memory allocated for the Bi-Tronics port buffer. You can designate the size of the printer buffer from 1 through 16 Kbytes.
* = Factory Default
Centronics (from page 115)
Data Bit 8 PI Ignored Data Polarity
Resp. Polarity
The Centronics submenu provides the options and settings available to configure the interface as required for your application. These options and available settings are outlined in the following paragraphs.

The Latch Data On parameter specifies whether the data is read on the leading or trailing edge of the data strobe signal.

Configures the amount of memory allocated for the Centronics parallel port buffer. The default is 1 Kbyte, but you can specify between 1 and 16 Kbytes, in 1-Kbyte increments.
* = Factory Default
Serial (from page 115)
Baud Rate Word Length
XON / XOFF* ETX / ACK ACK / NAK DTR
9600* 19200 38400 600 1200 2400 4800
8* 7 1* 2
None* Odd Even Mark Sense
True* On-Line and BNF Off-Line or BF False
On-Line and BNF* Off-Line or BF False True
The serial submenu allows you to choose the configuration of the Serial host interface type, as shown above. Several other serial parameters are included on this menu, as described below.

Interface Type
Allows you to select either the RS-232 (the default) or RS-422 serial port interface.
You can select one of the following serial interface protocols to meet the host interface requirements. • XON / XOFF. The default. The printer controls the flow of communication from the host by turning the transmission on and off.
In some situations, such as when the buffer is full or the timing of signals is too slow or too fast, the printer will tell the host to stop transmission by sending an XOFF character.
An XOFF character is sent when the number of empty bytes in the buffer is less than or equal to 25 percent of the buffer size.
If the host keeps sending data after an XOFF is sent, the printer firmware will continue to send an XOFF for every 16 characters received.
Sets the baud rate of the serial interface in the printer. Baud rate is the speed at which serial data is transferred between the host computer and the printer. The choices for the RS-232 and RS-422 interfaces are 600, 1200, 2400, 4800, 9600, 19200, and 38400. The default is 9600 baud.

Sets the length of the serial data word. The length of the data word can be set to 7 or 8 bits, and must match the corresponding data bits setting in the host computer. The default is 8 bits.
Sets the number of stop bits in the serial data word. Either one or two stop bits can be selected. The setting must match the corresponding stop bit setting in the host computer. The default is 1 bit.
Set for odd parity, even parity, mark, sense, or no parity. The setting must match the corresponding parity setting in the host computer. The default is None.
Configures the amount of memory allocated for the serial port buffer. The default is 1 Kbyte, but you may specify between 1 and 16 Kbytes, in 1-Kbyte increments.
Serial Submenu

Ethernet Submenu
* = Factory Default
Ethernet (from page 115)
The Ethernet interface allows you to locate the printer on a LAN rather than attach the host directly into the printer.
This option configures the amount of memory allocated for the Ethernet buffer. The default is 16 Kbytes. You can specify between 1 and 16 Kbytes, in 1-Kbyte increments.
Buffer Size in · 16* (1-16)

* = Factory Default
Bi-Tronics Centronics Ethernet Disable Trickle Time
RS-232* RS-422 Disable Trickle Time
1/4 sec* 1/2 sec 1 sec 2 sec 4 sec 8 sec 16 sec Off Timeout
1/4 sec* 1/2 sec 1 sec 2 sec 4 sec 8 sec 16 sec Off Timeout
10 sec.* (1-60) Report Status
10 sec.* (1-60) Report Status
Gives the printer the ability to handle multiple data streams sequentially. With Auto Switching, the printer can service hosts attached to the serial and parallel ports as if they were the only interface connected.
For example, if the host computer sends one print job to the RS-232 serial port and a separate print job to the Bi-Tronics parallel port, the printer's Auto Switching is able to handle both jobs, in the order they were received, without the user having to reconfigure the selected interface between jobs.
Allows you to select the types of parallel and/or serial interfaces which are connected to the printer. For example, if your printer is attached to one host with a Centronics connection and a second host with an RS-422 serial connection, you would select Centronics under the Parallel Hotport menu and RS-422 under the Serial Hotport menu.

Trickle Time
When the printer is printing data from a host and a second job is received by the printer from a different host, Trickle Time prevents the second host from timing out while it is waiting for its data to be printed. In order to support this feature, the port has to be able to accept data from the host and store it for future use.
For example, if the printer is printing a job from the serial port and then receives a second print job from the parallel port, the data from the parallel port will “trickle” bit by bit into the printer buffer to prevent a timeout error from being sent back to the host connected to the parallel port.
The selected value is the time that the printer waits before getting the next byte of data from the host. The Trickle Time value should be less than the host time out value, but not too much shorter or else the printer fills up its buffer too fast.
This is the value used by the printer to time out from the current port and check the other selected Port Types for data to print. When the printer has not received data from the host after a certain period of time, it needs to Timeout in order to service the other ports.

PARAMS
Subnet Mask MAC Address Novell Protocol
xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx hhhhhhhhhhhh Enable* Disable
Novell Frame PPM Port
Ethernet 802.2* 802.2 Snap Auto Sensing Ethernet II Ethernet 802.3
100 secs.* (1-255)
Auto Select* 10 Half Duplex 10 Full Duplex 100 Half Duplex 100 Full Duplex
1 If you change the Ethernet speed setting, you must also change the switch or hub setting to match.
The ETHERNET PARAMS menu helps your printer communicate on a network.
For information on assigning the IP Address, Gateway Address, Subnet Mask, and MAC Address, refer to Μετηοδσ Οφ Αδϕυστινγ Παπερ Ποσιτιον ον παγε 170.
You may also enable or disable the Novell or NetBIOS Protocols within this menu, as well as selecting which Novell Frame scheme is used in processing Novell signals. See Chapter 11, “Novell Configuration” for more details.
If the printer is connected to the Remote Management Software (RMS), the RMS Port number and PPM Port Timeout settings must match the settings in the Remote Management Software program.
A numeric address such as 123.45.61.23 which identifies a printer or server in a LAN or WAN.

Gateway Address
A gateway address is the IP address of a hardware device (gateway) that translates data between two incompatible networks, which can include protocol translation.
A binary value used to divide IP networks into smaller subnetworks or subnets. This mask is used to help determine whether IP packets need to be forwarded to other subnets.
This menu item is the Manufacturer’s Assigned Number, and is unique for each printer. It is read-only.
This option determines whether the Novell protocol will be available. The selections are as indicated below:
This option determines whether the NetBIOS protocol will be available. The selections are as indicated below:

The Printer Control Menu allows you to choose the printer's behavior. Options on this menu, as shown below, are described in the following pages.
Unidirectional PMD Fault Open Platen
15 mins.* (5 sec.-60 min.) Disable Instant
To select an option, press ENTER.
To return to main menu, press CLEAR.
To exit menu, press ON LINE.
* = Default Setting

Unidirectional
The Unidirectional feature affects both print quality and printing speed. By setting this feature, you can configure the printer to print in both directions of the shuttle sweep (bidirectional), or to print in one direction only (unidirectional).
You might want to enable this feature when printing bar codes, high quality text and graphics, or other printing that requires precise vertical alignment.
Some special forms have perforation areas that are too thick to pass through the print station. This parameter, when enabled, opens and closes the platen when the perforations move across the platen. When enabling this parameter, you must set the forms length to match the physical distance between perforations.

Power Saver is also referred to as the ENERGY STAR® Office Equipment Program. The Power Saver feature places the printer in “sleep mode” when the printer has not been used for a specified number of minutes. In sleep mode the printer is in low-energy idle state, all fans and higher voltages are off, and only +5Vdc logical circuits are active.
You can designate the number of minutes after which the printer will go into sleep mode. The range of time is from 0 to 60 minutes. The default is 15 minutes.
Pressing any key on the control panel or sending a print job to the printer will turn off sleep mode.
The diagnostics menu allows you to choose the diagnostics tests to be run and provides you with important system information. Options on this menu, as shown below, are described in the following pages.
1If Ethernet adapter is present
Printer Tests Test Width Paper Out
Shift Recycle* All E’s E’s + TOF All H’s All Underlines All Black Shuttle Slow Shuttle Fast Shuttle Only Phase Printer
Full Width* 80 columns 40 dots* (4-76 dots)
217* (500 lpm) 123* (1000 lpm) 62* (1500 lpm) (1 to 2000) Paperout Adj. Burnin Test Print Error Log Clear Error Log E-Net Test Page1

Printer Tests
The printer tests are used to check the print quality and printer operation.
The Phase Printer test checks for wavy print. The initial phase value is set in the factory. The Customer Service Engineer (CSE) runs the test and checks the quality. (The phase value prints on the left margin.) If the print looks too wavy, the CSE changes the Phase Value parameter by pressing the key while the test is running. A value between 1 and 2000 displays. To change the value, the CSE presses theorkey until the desired value displays, and then presses ENTER.

This parameter permits you to run the self-tests at full width or 80 columns.
It is recommended that only an authorized Printronix representative sets this parameter.
Paper Out Dots allows the Customer Service Engineer to specify where the last line on the page will print when there is a paper out condition. Setting this parameter correctly prevents printing on the platen.
This parameter displays the amount of RAM installed.
Auto Switching Submenu

Print Statistics
You can view various printer statistics, such as hours of usage, and refer to these figures for preventive maintenance purposes. Printer statistics accumulate continuously; they do not reset when you turn off the printer.
RibbonMinder is a user-definable software feature which notifies the user when a ribbon should be changed. It does this by monitoring ink consumption and alerts you when the print quality falls below a level you designate. This is especially important if you are printing bar codes to be scanned.
ON LINE 100%
As printing continues, the percentage of usable ink in the ribbon decreases.
ON LINE 74% Ribbon ink being consumed
ON LINE 8% Ribbon life approaching end
When 0% usable ink appears, the printer is typically configured to stop printing and display the following message:

MINDER
New Rib.
Press ENTER to reset ribbon life to 100%. NOTE: If New Ribbon Detect is set to “Enable”, the Ribbon Life will automatically display 100% when the ribbon is changed.
Display* Fault Immed Fault Paper Out Disable
Gold Series 90 Gold Series 50 Gold Series 30 Gold Ser. 2000 Printronix 100 Printronix 60
Extend 100% ...(by 5%) Extend 5% Normal* Reduce 5% ...(by 5%) Reduce 100%
This provides a means to manually set the printer when a new ribbon has been installed. The ribbon life displayed on the control panel (if active) is set to 100%. The count internal to the printer will also be reset, and the tabulation towards end of ribbon life will begin.
Ribbon Action • Display. The factory default for this setting is the DISPLAY mode. When DISPLAY is selected, the ribbon ink consumption will continually display on the control panel, decrementing as ink is consumed. When the ribbon life reaches 0%, the message RIBBON INK OUT / CHANGE RIBBON displays on the control panel. The printer will continue to accept new print jobs. No other indication (no flashing light, or warning beep) is given. The display can be cleared by replacing the ribbon when NEW RIBBON DETECT is enabled.

In this mode, the Ribbon Minder is automatically reset when a “clean hands” ribbon is installed and NEW RIBBON DETECT is enabled. If another type of ribbon is used, the User must reset the Ribbon Minder using the New Ribbon menu selection. • Disable. When DISABLE mode is selected, the ribbon life display is removed from the control panel, but the Ribbon Minder continues to monitor ink consumption. No indication (no flashing light, or warning beep) is given, and the printer continues to accept new print jobs indefinitely.
disabling the ribbon action will not clear the message.

The factory default setting is dependent on the host printer. Printronix Gold Series 90 corresponds to the Cabinet version, Printronix Gold Series 60 for the Pedestal and Printronix Gold Series 2000 for the P5220. The relative length equivalents for each of the ribbon settings are:
Table 12. Length Equivalent Ribbon Settings
Ribbon Type (Char) Equivalent Length Actual Length
Gold Series 90 (90 million characters)
80 yards 90 yards
Gold Series 50 (50 million characters)
100 yards 55 yards
Gold Series 30 (30 million characters)
60 yards 40 yards
Gold Series 2000 (60 million characters)
100 yards 80 yards
Printronix 100 (50 million characters)
100 yards 100 yards
Printronix 60 (30 million characters)
60 yards 60 yards
The factory default is NORMAL. This value corresponds to the character life expectancy of the installed ribbon. For example, the life of the Gold Series 90 ribbon is specified at 90 million characters. By selecting NORMAL Ribbon End Point, the Ribbon Minder will track characters up to 90 million before declaring RIBBON INK OUT / CHANGE RIBBON.
By changing this setting, the user can specify a point lower or higher at which the RIBBON INK OUT / CHANGE RIBBON message is displayed. Using the example above, if the Ribbon End Point is set to Reduce 50%, the RIBBON INK OUT / CHANGE RIBBON message would display at 45 million characters. If Ribbon End Point was set to Extend 50%, the message would display at 135 million characters. In this way, the user can set ribbon life to match the required print density for the application.
Ribbon Minder Ink Consumption display tracks the consumption based on the adjusted Ribbon End Point. For example, if the Ribbon End Point is set to Reduce 50% (45 million characters for the Gold Series 90 ribbon), the Ribbon Minder Ink Consumption display will start at 100%, and decrement to reach 0% as 45 million characters are printed.
RibbonMinder Menu

If the Ribbon Type is changed from the factory default to another value, Ribbon Usage will adjust accordingly, where 100% corresponds to the proportionate value of the selected type. For example, if the Ribbon Type is set to Printronix 60 (approximately 30 million), Ribbon End Point set to NORMAL would correspond to 30 million characters. With this same 60 yard ribbon, if Ribbon End Point was set to Reduce 50%, the character count would be set to 15 million, etc. Ribbon Minder will track the ink consumption based on these new parameters, display 100% when a new ribbon is installed and tracking usage to 0%.
but by an accumulation of a specified number of printed dots in any one of a number of pre-defined vertical zones. It is stated here as a function of characters printed for user clarity.
The factory default setting is Enable. When the RIBBON INK OUT / CHANGE RIBBON message displays, and a new ribbon is installed with New Ribbon Detect enabled, the Ribbon Minder will automatically reset by opening the platen. If New Ribbon Detect is set to Disable, the Ribbon Minder must be manually reset by using the New Ribbon function.

Overview
Configuring your network printing is based on the network protocols and host environments you already use or plan to use. It is common to find multiple network protocols co-existing in the same network.
NIC is a multi-protocol device that is able to accommodate many protocols at the same time. The actual print job order operates on a first-in/first-out basis. This means it is possible to configure your NIC using any or all of the methods listed in this manual for use at the same time. This concept is what creates the ability to use powerful printer management tools in parallel with the act of printing. The protocol for a print job and the protocol for the management tool will often be different.
These ideas are also what differentiate networks by size and network protocol use. Some common network arrangements include peer to peer networks and print job servers.
Peer to peer networks can be used when you have few machines, few printers, only one network protocol, and when any host can print to the printer. A variation of this is a mini-server which “shares” its printer with the other networked computers in a single room or building. NIC improves flexibility in printer placement and setup by becoming just another “peer,” rather than dedicated to a single machine.
A common peer to peer network arrangement is comprised of Windows 95/98 with TCP/IP configured to use the netBEUI protocol to connect to the print server. A second common extension of this arrangement is to install a third party LPR PORT MONITOR on each PC and use simple TCP/IP to connect to the print server. If Windows NT is used for the peer computers, LPR is included and is easy to set up. Windows 95/98 does not have such a monitor, but many are available for free for download from the Web.

Print Job Servers
In most larger networks, print jobs usually are managed by designating one protocol and method for printing and then designating specific computers as print job servers, rather than by directing any host running any protocol to the networked printer resource. Computers designated as print job servers have large hard disk space to store print data and spool management software. All clients direct their print job to the computer designated as the print job server rather than the printer; therefore, the client to print job server network protocol used might not be the same as the print job server to NIC. Large network environments today are generally TCP/IP or Novell network protocols or a mixture of the two.
NIC implements a logical printer architecture which gives the system administrator the possibility to configure the print server to handle and act upon the print data in several ways. When a print job comes through the print server, there is a certain logical print path that it follows before it gets to the printer. Each logical print path consists of a sequence of logical steps where extra processing may be performed on the print data before it is sent to the printer. This ability to preprocess the print data before it is sent to the printer allows elimination of printing problems, or implementation of printer enhancements that may be difficult and time consuming to solve or introduce at the system, spool or queue level, yet be simplistic to perform at the print server level.


Figure 13. Print Path
For every I/O port on NIC, there is at least one pre-defined logical print queue or destination to accept print jobs destined for it. This includes print jobs that are sent directly to the I/O port, such as port 9100. These queue or destination names are pre-defined but can be changed by the user.
Logical Printer Architecture

Models
For every destination or queue, there is a pre-defined model associated with it. The model defines how the print job will be processed as it passes through to the printer. Models are a set of mini filters that can be used to modify the print data stream. The functions available for each model are as follows:

Overview
The NIC comes with an extremely powerful printer management tool that allows you to monitor, configure, and manage both the printer and its print job. The NIC comes with an embedded web server that allows System Administrators and users access to its printer management capabilities from a standard web browser.
The NIC printer’s IP address is used as a URL, similar to the URL of an Internet web page. When a web browser is activiated and the printer’s IP address is entered, the printer’s embedded web server displays its home page, with links to the printer’s status and configuration settings.
All of the NIC’s configuration settings are protected by a password so unauthorized users cannot make changes. When you try to open any of the NIC’s configuration pages, you are asked for your user name and password. At the prompt, enter root (unless you have another user configured with root privileges) followed by the associated password. If there is no password, press ENTER. For more information on setting passwords, refer to “NIC Security” on page 259.
When you configure settings on the NIC and press the SUBMIT button on the related form, re-power the NIC to ensure the latest settings are in use. To reset the NIC, select System Form from the Configuration Menu and click the REBOOT button.
The embedded NIC Web server gives you the ability to configure the network adapter, monitor printer status, and to manage print jobs. The NIC Web Page structure is divided into several menus as shown in Figure 14.

Configuration
SNMP Print Model Print Path Network Log Path
d1prn d2prn d3prn d4prn d5prn d6prn d7prn d8prn
Alert Config 1 Alert Config 2 Alert Config 3 Alert Config 4 Alert Config 5 Alert Config 6 Alert Config 7 Alert Config 8 Alert Config 9 Alert Config 10
Figure 14. NIC HTML Structure

The network configuration allows you to specify the setting for each network protocol. Beside each protocol name is a check box which allows you to enable or disable each protocol depending on your network printing needs.
The two edit fields contain the NIC’s IP address and subnet mask. The check boxes enable the RARP and BOOTP protocols, which are alternate methods of assigning IP addresses. On most networks, you want to enter a permanent IP address and subnet mask and disable RARP and BOOTP. However, if your network requires one of these, you should clear the IP address (and possibly the subnet mask) fields and ensure that the appropriate check box is selected.
The routing table tells the NIC which router or gateway to use to access other subnets or hosts. In most situations, you can add your router's IP address as the default router. All packets destined for other subnets will be forwarded to the default router for delivery to the destination host. If you have more complex routing requirements, add static routing entries for specific hosts or networks in the remaining Routing rows. Packets with IP addresses that match a given Destination and Mask (from the first two fields in a Routing row) route to the router/gateway named in the third field. Packets which do not match any of the listed Destinations and Masks route to the default router if one is set.
TCP/IP Network

Windows Network (NetBIOS TCP/IP)
TCP/IP is used for Windows (i.e. Windows NT, Windows 95, and Windows for Workgroups) printing unless another protocol like IPX is available. Therefore, mandatory TCP/IP settings (i.e. IP address and subnet mask) are necessary on the NIC. Go to "TCP/IP Network" on this form to fill in these settings if you have not done so already.
This name specifies which Windows workgroup the NIC resides.
Defines the packet structure of transmitted data or the control commands that manage the session, or both.
This option determines which framing scheme will be used in processing Novell signals. The different types of Ethernet packet formats include:
Allows you to change the Nest Server. The options are: • Binary
Define a Novell file server for the NIC to service as either a PSERVER or an RPRINTER.
NDS (Novell Directory Services) is a distributed database of network information. An NDS contains information that defines every object on the network. For more information please see your Novell administrator.

Define a password for the NIC to use when logging in to the file server as a PSERVER. This is an optional file server security feature.
Define an RPRINTER setup so the NIC knows to service a PSERVER.NLM on a Novell file server. Define the PSERVER.NLM name, the number of the printer serviced by the NIC within this PSERVER.NLM, and the destination on the NIC you want the print jobs to pass through.
The NIC print path is the path a print job takes when it reaches the network adapter. First the job goes to a destination/queue (e.g. d1prn) where it then passes through an associated model (e.g. m1) for extra processing and logpath (e.g. l1) for job and printer logging. Finally the job reaches the NIC's I/O port (e.g. PRN) where it passes through to the attached printer. The "Print Path" form displays one destination's settings at a time. From here, you can then select another destination or you can go directly to an I/O port to configure port settings.
Name of the destination. The default destination queue names are d1prn, d2prn, d3prn, and d4prn.
I/O port to receive printer feedback when a print job passes through this destination. By default d1prn, d2prn, d3prn, and d4prn have no backchannel.
Destination Settings

Selected Model
Defines the model configuration that is to be associated with the current destination. The default model names are m1, m2, m3, m4, m5, m6, m7, and m8.
The option is available on the Print Model web page. For a description, see page 147.
The option is available on the Print Model web page. For a description, see page page 147.
The option is available on the Print Model web page. For a description, see page 147.
The option is available on the Print Model web page. For a description, see page 147.
The option is available on the on the Print Model web page. For a description, see page 148.
The option is available on the Print Model web page. For a description, see page 148.
This option defines the log path configuration that is to be associated with the current destination.

Current Log Path Settings
The option is available on the Log Path web page. For a description, see page 148.
The option is available on the Log Path web page. For a description, see page 149.
Name of the model. The default model names are m1, m2, m3, m4, m5, m6, m7, and m8.
Define what processing (if any) will be performed on print jobs passing through the associated destination. If set to "raw", the job will not be touched by the network adapter.
Tell the Ethernet Interface to produce a banner page with each print job. The type of banner page data can be text. You can also specify whether the banner page should come at the front or the end of a print job.
Specify whether the Ethernet Interface is to add carriage returns to print jobs passing through that contain solitary linefeeds. This is common with Unix text jobs resulting in stair-stepped output.
Define an escape sequence to be sent to the printer before each print job. For example, you may want to send a sequence to print the job in landscape mode or to a certain tray on the printer. You can specify up to four separate sequences per header string. The Ethernet Interface will execute them in order from top to bottom. If specifying fewer than four sequences, be sure to start at the top leaving undefined fields at the bottom.

Trailer String
Define an escape sequence to be sent to the printer after each print job. For example, you may want to send a sequence to add a formfeed so you don't have to manually press the formfeed button on the printer. You may also want to tell the printer to reset itself in case you have set a header string which tells the printer to do something special with the job. You can specify up to three separate sequences per trailer string. The Ethernet Interface executes them in order from top to bottom. If specifying fewer than four sequences, be sure to start at the top leaving undefined fields at the bottom.
The most common sequences are listed on the form:
Specify a printer configuration number to be loaded before processing the print job. This ability to associate a printer configurations to a logical printer model allows you to define up to four unique and independent printer personalities in a single printer. Using this feature, you effectively have four different printers in one.
To associate a printer configuration to the currently selected destination queue, just select the desired printer configuration number from the drop down list. Once a printer configuration have been associated with a destination queue, any print job sent to that destination queue name will cause the printer to load the associated printer configuration before processing the print job.
Name of the log path. The default names are l1, l2, l3, l4, l5, l6, l7, and l8.

among all destination queue.
Default: no logging turned on.
I/O port configuration can be reached through a Print Path destination form (by clicking on a port) or through the I/O Port option under the Configuration Menu.
The parallel port on the Ethernet Interface can have its throughput altered by selecting a particular “Mode”. The choices are:
Parallel Port (PRN)

Configuration – SNMP
The SNMP Configuration form allows you to configure SNMP trap managers and the e-mail alert features of NIC. It allows you to configure how SNMP alerts are processed by a SNMP trap manager, an Unix syslog logging daemon, and/or have e-mail notifications sent. Up to 10 SNMP trap managers and e-mail recipients may be specified. Individual alerts fall into one of 12 alert group categories, providing the ability to filter alert notices as desired.
Specifies whether alerts from the enabled alert group categories for this configuration will be sent to the SNMP manager. If this option is enabled, the following information must be entered:
Specifies whether alerts from the enabled alert group categories for this configuration will be sent to the Unix syslog daemon. If this option is enabled, the syslog daemon IP address must be entered in the syslog field in the Logpath Port section under the PrintPath menu item.
Specifies whether alerts from the enabled alert group categories for this configuration will be sent to the specified e-mail address. If this option is enabled, the following information must be entered:
If enabled, the message will contain the alert description, the severity level, and device name (unless the length of the message exceeds the Short E-mail Message Length, in which case the message will be truncated.

If disabled, the message will contain additional information including the device name and location, alert description, alert group, and alert severity level, and printer status.
Default: Disabled • Short E-mail Message Length - Specifies the maximum size of the short e-mail message. Acceptable values are 15 to 80 characters.
Default: All alert groups are disabled by default.
If the alert message is to be sent to a cellular phone or pager, the Short E-mail Format option should be enabled. Once this option is enabled, you may specify the maximum e-mail message length (15-80 characters). When enabled, the message will contain the alert description, the severity level, and device name (unless the length of the message exceeds the Short E-mail Message Length, in which case the message will be truncated).
If the Short E-mail format is disabled, the message will contain additional information including the device name and location, alert description, alert group, alert severity level, and printer status.
To test the validity of the e-mail address and the SMTP server address, enable the Send Test Message option. If the Send Test Message box is checked, a test message will be sent to the specified e-mail address when the submit button is pressed.
Specifies which alert groups are enabled for reporting for this configuration. When an alert occurs that is contained in one of the enabled alert groups, it will be posted to the specified SNMP manager, Unix syslog daemon, and/or e-mail address. The following table describes which printer events belongs to which Alert Group.
Default: All alert groups are disabled by default.
Parallel Port (PRN)

Table 13. Alert Groups and Printer Events
Alert Group Printer Events
Offline Printer is Offline Hold Print Time Out
Media Input Load Paper Paper Out Time Out Fanfold Paper Empty No Fanfold Paper 63-CutSheet Feeder Fail Cutsheet Pick Miss No Paper Tray Paper Jam at Entrance Cutsheet Cover Open Cutsheet Paper Empty Tray Mismatch
Media Output Stacker Full Stacker Jam Time Out Stacker Full Time Out Stacker Fault Time Out Stacker Jam Stacker Fault Stack Over Flow Stack Under Flow Stacker Fail Stacker Interlock Fail Stacker Not Ready

Table 13. Alert Groups and Printer Events
Alert Group Printer Events
Media Path Clear Paper Jam Paper Jam Time Out Paper Jam Fuser Paper Jam Exit Cutsheet Path Open Paper Jam at Drum Paper Jam at Fuser Paper Jam at Exit Tractor MTR FWD Speed Error Tracker MTR BKWD Speed Error Paper Jam at Entrance Cutsheet Motor Fail Cutsheet Feeder Fail Clear Jam at Fuser Input Clear Jam at Fuser Exit Clear Jam Near TOF Lever
Marker Ribbon Stall Time Out Ribbon Ink Out Ribbon Stall Ribbon Drive Shuttle Over Speed Ribbon Fault Ribbon Detected Print Head Up Ribbon Broken Ribbon Load Bad Ribbon Take-up Full 2A-Toner Empty Add Toner Install Toner Cup
Cutter Cutter Fault Cutter Fail
Barcode Barcode Fail Specification Barcode Quiet Zone Too Small Barcode Improper Data Format
Scanner Unscannable Check Media Poor Scanning Check Head and Heat Poor Scanning Inspect Head Poor Scanning Check Media Contrast Too Low Check Media
Intervention These are error messages that need some kind of user intervention to solve them.
Consumable Ribbon Low Toner Low
Parallel Port (PRN)

Table 13. Alert Groups and Printer Events
Alert Group Printer Events
Label Label Present Gap Not Detected
available for monitoring will depend on the printer type and the options installed on the printer.
The Administration Configuration form is broken down into general print server-related settings and password security.
The System Information form allows you to specify the following information about the printer: • Name - name given to the print server in Novell and Windows environments. The defaul name is "M_xxxxxx" where "xxxxxx" equals the last six digits of the network adapter's Ethernet address. (e.g. M_031C1A)
Only a user with root privileges can alter the NIC's settings. Guest users can only view settings but cannot alter them. Both types of users can be assigned passwords. To change a password, type in the old password in the "Old" field. Then type the new password twice: once in the "New" field, and once in the "Confirm" field.
Default: No passwords for root or guest users.

The System Configuration form allows you to change the NIC 's operation mode. Select "Reboot" to re-power the print server. Select "Default" to reset the print server and have it come up with factory default settings.
The Status menu items allow you to view the current status of both the printer and the network. The submenu items available are as follows:
The I/O Port Status form allows you to remotely see what is happening on the NIC I/O port. The port's status and a list of active and queued jobs will be displayed. You can cancel a job (as long as you have permission to) by clicking on the Cancel icon beside the desired job. If you see "waiting" in the "Status" line, this indicates the network adapter is either waiting for data from the host or for feedback from the printer. If you see "blocked" in this line, this indicates the printer is not allowing the NIC to send anymore data. The printer could be busy processing data it has already received or it could be in an error state.
The printer status display is automatically refreshed every minute.
the Cancel icon.
This form allows you to view the current status of the network. The statistical data provided is broken down by network protocol. You can use this form to troubleshoot network-related problems.
Passwords


TCP/IP NIC Configuration
This configuration procedure assumes you have an existing network and TCP/IP attached to a Windows 95/98/NT, Unix, or other machine.
You will configure network printing by adding the necessary TCP/IP values to the NIC and associating the Print Server as an output port for a Windows printer on a 95/98/NT client or server, or to a print queue or logical printer in Unix, AS/400, or HP e3000.

Creating Aliases
All TCP/IP systems are designed to make multiple operations easy by using an alias, which is a logical name to IP/MAC address association. This step is important in the Unix world if DNS (Domain Name Services) is being used; it can also simplify the other environments.
Locate the hosts file. (If you are using Windows 95/98 and have never had a hosts file, you can create one by using Notepad or any other text editor and saving it to the Windows directory.) Edit the file to add your new P5000LJ Printer, and save the file. Rebooting is not necessary.
Location of hosts file:
Windows 95/98 windows NT windows/system32/drivers/etc Unix /etc HP e3000 host.net.sys
Example of entries in a hosts file:
10.200.30.123 printer1 10.200.30.130 accounting 192.168.2.33 next_state 10.200.30.18 MIS
In most Unix systems using DNS, a hosts table is constructed as shown above. The file nsswitch.conf or its equivalent is then edited to associate a MAC (hardware address) to an IP address in the hosts file. In doing this, any individual client workstation needs only a single address entry—specifically, the DNS host address—as a ping to printer1 is actually resolved by the DNS machine and returned to the client workstation. This means an administrator need maintain only one hosts file for all to use, making updating central.
For peer to peer and small networks, using a local hosts table on each workstation can function in place of DNS.

Methods For Setting TCP/IP Values
Methods available to set TCP/IP values vary based the operating environment (see Table 14).
Table 14. Available TCP/IP Setup Methods
Operating Environment arp bootp DHCP
Windows 95/98
AS/400 *
If you are unsure which method to use, you can use the front panel of the printer to set the TCP/IP values without a live network connection.
For bootp, arp, and NetBEUI/NetBIOS, the MAC address of the NIC is required. If the NIC is pre-installed, the MAC address can be obtained by using the P5000LJ printer diagnostic print test E-Net Test Page, or by using the printer control panel to view the MAC Address value in the ETHERNET PARAMS configuration submenu (see page 125 for details). In addition, a label attached to the rear of the printer shows the MAC address, which reads 00:80:72:xx:yy:zz. This value is also known as the “hardware address” or “ethernet address.”
The DHCP is useful to locate a print server. DHCP generally is not useful for using other than NetBEUI/NetBIOS, as most queueing mechanisms need to know the static location (IP address) of a printer, and with each DHCP power on cycle will likely change.

Assign TCP/IP Values
Method 1: Using the Printer Control Panel
All of the basic TCP/IP values can easily be set and stored in the NIC via the printer front panel under the ETHERNET PARAMS menu. Refer to “Configuration Using The Printer Control Panel” on page 68 for detailed instructions.
Set the IP Address, Subnet Mask or Gateway Values, then press the ON LINE key to store those values in the NIC. These steps do not require the printer to be connected to your network.
If you receive a “reply received from…” message, then proceed. If you get a “destination unreachable” message or “no reply from...” message, recheck values and cables you have used.
Once you have established a positive ping response, you may wish to use a browser to change or set items (such as the workgroup name to match that of your client network), or to change other values or names or check printer status. To do this, open your browser. In the URL line, enter the IP Address of the NIC and press ENTER. When the P5000LJ Series Printer Web Page displays, click on “Configuration.” When prompted for a user name and ID, enter root and press ENTER. Press ENTER again for a blank password. You may now change the workgroup name and other values.
If your web browser is set to use a proxy (or you don’t know), use a telnet command session order to finish your setup using store and set commands (refer to Chapter 13, “Commands”).
Use the following example of a telnet session to change the Windows workgroup name in the NIC from “workgroup” (the default) to “Acme.”

For Windows 95/98/NT or OS/2, open a DOS window. For AS/400, start from a command prompt. For Unix, start from a terminal session prompt:
telnet xxx.xxx.xxx.xxx > login > user ‘root’ (default user name for configuration) > anything (default is no password) > welcome root user (sample response) > store pserver smb workgroup Acme > ok > reset (print server will need about 30 seconds to reset) session disconnected
Start with the printer powered off. Have the IP Address, Subnet Mask, and Gateway values ready.
For arp assignment, the syntax is: arp -s ipaddress MAC_address
Example using Windows 95/98/NT:
On a DOS command prompt, enter: arp -s 192.168.20.20 00-80-72-09-00-5F (set the static arp value; be certain to replace the IP Address of this example with a valid one of your own) list arp -a (to ensure you have the “static entry”)
Example using Unix (not AIX):
On a command prompt, enter: arp -s 192.168.20.20 00:80:72:09:00:5F (set the static arp value; be certain to replace the IP Address of this example with a valid one of your own)
Example using AIX:
On a command prompt, enter: arp -s ether 192.168.20.20 00:80:72:09:00:5F (set the static arp value; be certain to replace the IP Address of this example with a valid one of your own)
Assign TCP/IP Values

Now power the printer up, and wait a minute or more for the NIC to obtain the address above.
Test by issuing the command ping IP_address.
If you do not get a positive ping response, check your arp table entry, and check that the printer is on the same “wire” as you (the same IP address range, different only in the value after the last period). Verify that you have not typed an IP address that you or someone else is already using. If you have, type the command arp -d IP_address at a DOS prompt to delete the incorrect entry and then type the correct value.
If you do get a positive ping response, remove the static arp entry (to avoid conflict) by using either telnet or a web browser. At a DOS prompt, type the command arp -d 192.168.20.20 (with your own IP Address value in place of this one). Then store this value into the NIC.
Using a DOS window (or a third party tool capable of a telnet session), use the following:
telnet xxx.xxx.xxx.xxx or hosts_table_name login: root (default) password: (no password is default) welcome root user> (ignore warning messages about differences) store TCP/IP 1 addr from current (save the arp assigned value) list TCP/IP (you will see your IP address and a subnet address. If the subnet address is incorrect, use the following command to modify it) store TCP/IP 1 mask 255.255.255.0 (enter your mask value in place of this one)
If you have a gateway value, enter it now using the following commands:
store TCP/IP add default router gateway_value 1 reset (after a minute or so, you should be able to ping the print server)

Initiate the Web browser and enter the IP Address or hosts table name in the URL line.
Click on “Configuration.”
Log in as root, no password.
Enter the values you need for subnet mask and gateway and click “Submit.” Delete the static arp entry: at a DOS prompt, type the command arp -d 192.168.20.20 (with your own IP Address value in place of this one). Then click on “System Administration” and “Reset Adapter” to store the values
Note Windows 95/98 pre-winsoc2 TCP/IP has a bug in which an arp entry will not be created unless a valid arp entry exists in the arp table on the client you are using. To ensure you have a valid arp entry, ping your own workstation in the DOS window and type the command arp -a to view the arp table before using the arp -s command.
BOOTP allows you to assign an IP address to the NIC upon bootup. In addition, the BOOTP server can provide additional details such as a default router/gateway address. To configure the NIC with its TCP/IP settings using BOOTP, complete the following steps.
Syntax: NICIPname:\ :sm=netmask:\ :hd=homedirectory:\ :bf=null:\ :gw=defaultgateway:\ :ht=ethernet:\ :ha=ethernetaddress:\ :ip=ipaddress:\ :ts=timeserver:\ :to=timezone:
Example:
spike:\ :sm=255.255.255.0:\ :hd=/usr/null:\ :bf=null:\ :gw=192.75.11.1:\ :ht=ethernet:\ :ha=008072070060:\ :ip=192.75.11.9:\ :ts=192.75.11.7:\ :to=25200:
Using BOOTP


Overview
This chapter details the HP e3000 Host Configuration setup and NIC setup.
Note With the release of MPE/iX version 5.5 and higher, it is now possible to use the spooler on the HP e3000 to control printing on devices attached to a network. The Native Mode Spooler Reference Manual (HP P/N 32650- 90166, Edition 5, Sept. 1998 or later) and Configuring and Managing MPE/ iX Internet Services (HP P/N 32650-90835) are essential references to assist you in this configuration.
Follow the instructions below to configure printing to a NIC by using TCP/IP print to socket, sometimes referred to as “native tcpip mode.” The configuration parameters are set via entries in the file “npconfig” (npconfig.pub.sys).
a. log in as MANAGER.SYS
b. enter the command :run sysgen.pub.sys
c. at the > prompt, enter io to start the I/O configurator
d. enter the command io> ad ldev=xx;id=HPTCPJD;path=NONE
HPTCPJD is the HP-supplied logical network device type.
e. enter the ld xx configuration command to view the addition, where xx is the logical device number you chose in step d.
f. enter the commands: io> hold (to save the I/O configuration) io> exit (to exit the I/O configurator)

g. at the SYSGEN prompt, enter the commands: SYSGEN> keep SYSGEN> exit
h. to have the new configuration take effect, reboot the system with the command, start norecovery. It is also possible to configure the device online by using the command, ioconfig.
You can assign these values to NIC by entering the values in the printer control panel (see page 68), or by using the bootpd process as described in Configuring and Managing MPE/iX Internet Services. If you use bootpd, create an entry in the bootpd configuration file for each NIC you are adding. For example: printer1: ht=ether: ha=00807209yyyy: ip=xxx.xxx.xxx.xxx:\
In this example, the ha value is the MAC address of NIC being added. Replace yyyy with the last four digits of the MAC address for the individual print server. If NIC is pre-installed, the MAC address can be obtained by using the P5000LJ Series printer diagnostic print test E-Net Test Page, or by using the printer control panel to view the MAC Address value in the ETHERNET PARAMS configuration submenu (displayed on page 125). In addition, a label attached to the rear of the printer will show the MAC address, which reads 00:80:72:xx:yy:zz.
a. telnet xxx.xxx.xxx.xxx or telnet host_name (example: telnet 192.192.192.192 or telnet LJ50001)
b. log in as user name root, no password (or by using the user name and password you may have stored in the adapter).

c. set dest d1prn backchannel prn save list dest (this will allow you to see your change) exit
Create or modify the npconfig file. As a starting point, you can use the system file npconfig.samp.
For each logical network printer that points to a physical NIC using the npconfig file entries, make the following minimum entries (assume a logical device 201 has been set in sysgen):
201 ( network_address = xxx.xxx.xxx.xxx tcp_port_number = 9100 pjl_supported = true snmp_enabled = false jam_recovery = false data_timeout = 30 )
The entry snmp_enabled = false must be entered as shown.
If you have other HP LaserJet printers already configured while using a global setup_file entry, and you experience font or other difficulties with the P5000LJ line matrix printers, create a separate setup file which is empty to override the global entries. This may be required since the P5000LJ printer uses PCL Level II, which is a minimal set of PCL, and the typical HP e3000 global setup file may contain PCL commands beyond those in PCL II. This will not affect your ability to use the P5000LJ printer effectively. The syntax for the setup file is setup_file = name.
Use npconfig entries banner_header and banner_trailer for banner or trailer pages. Be aware that the default value is “true,” so banners will print by default.

NIC Configuration Verification
1. Print the Current Configuration in the printer and verify the installed Function Code. Install the latest version via ftp if not present and reenter all printer configurations. The Function Code version installed is listed as "Program File Version xxxx Part No. xxxxxx" at the top of the configuration printout. Ethernet Version is a few lines below the program File version on the configuration printout. The Ethernet firmware version must be 1.1.3 or later and is only copied to the printer when the Function Code is loaded via the Network Interface (via ftp).
a. Under Host Interface, verify Ethernet is selected and change the buffer size to 8K (from 16K).
b. Under Ethernet Parameters, verify the IP address, Subnet mask, and Gateway are correctly listed.
c. If you are not using Novell or NetBIOS for network printing, disable Novell and NetBIOS under Ethernet parameters. This avoids unnecessary protocol broadcasts.
a. OFFLINE / CONFIG CONTROL
b. LEFT ARROW twice to PRINTER DIAGNOSTICS
c. DOWN ARROW to PRINTER TESTS
d. DOWN ARROW again to SHIFT RECYCLE
e. LEFT ARROW to E-NET TEST PAGE (or, if something else displays, press left arrow repeatedly until E-Net Test Page is displayed).
For example, if the desired Netmask is listed as 255.255.255.0 under Network Information, and if the Netmask is listed as 255.255.255.255 under TCP/IP Routing Table, then the Netmask does not match and you must correct the Netmask.
To correct an incorrectly associated Subnet mask (Netmask) complete the following steps:
a. Take the printer offline.
b. Modify the Gateway from the front panel to the default address of 0.0.0.0.

c. Place the printer online and wait for the front panel to display “E-Net Ready.” This will write the Gateway address to the network I/F NvRam.
d. Take the printer offline and enter the desired Gateway address.
e. Place the printer online and wait for the front panel to display “E-Net Ready.” This will write the Gateway address to the network I/F NvRam.
f. Print E-Net Test Page and verify both listed Netmasks are the same and that xxx.xxx.xxx.xxx is alive is printed under Default Gateway Ping Test (xxx.xxx.xxx.xxx = Gateway IP address).
5. Inspect “Printer Destinations” on the E-Net Test Page. Reprint the E-Net Test Page and verify the backchannel is set to prn for the d1prn queue. On an HP e3000 host, prn must be listed under BACK for the d1prn queue so that Printer Job Language (PJL) will operate properly. (PJL must be operational for Page Level Recovery [PLR] to function.) The backchannel for the d1prn printer queue can be set with a telnet session from a PC running a DOS session as shown below:
C:\telnet 15.31.40.147 Network Printer Server Version 1.1.3 (15.31.40.147) login: root Password: (carriage return) Welcome root User 15.31.40.147:root> set dest d1prn backchannel prn ok 15.31.40.147:root> save 15.31.40.147:root> exit
npconfig.pub.sys Listing Comments
6 Network Address = 192.6.1.71 IP address - no leading zeros
tcp port number = 9100 This line optional
setup file = SETUP6.PUB.SYS Optional - specific setup file for LDev6
pjl supported = TRUE Required for PLJ to function
snmp enabled = FALSE Required
data timeout = 30 Required
banner header = false Optional - turns off headers
banner trailer = false Optional - turns off trailers

The line setup_file = filename is the file that contains customized setup strings to specify the printer operating mode for this logical device. This file must be an unnumbered file. When no setup file is specified, the default MPE/iX environment or the global setup file is applied at print time to the printer. The spooler will send the contents of the setup file, even if it is empty, which overrides its own default initialization. So, for example, if you want the pitch to be determined by the printer’s front panel setting (e.g., CPI 10, etc.), set the setup_file to an empty file.
As we have changed some configuration values in this procedure (Host Interface Buffer size), you must save this configuration to a numbered location (1-8) and designate that configuration as the power up configuration. Failure to save and designate the saved configuration as the desired power up configuration will result in problems, such as loss of communication, after powering off/on the printer.
When the HP e3000 spooler is active and the paper needs to be adjusted (the print is too far up or too far down on the page) or replaced, use one of the methods below to set the paper position. You can also defer printing or temporarily stop the spooler (stopspool nn) to ensure no print jobs will release.
When the HP e3000 spooler owns the printer, the FF, LF, and Set TOF keys do not operate. If you press any of these keys, the message “Invalid Key - Press View” displays. (If you want to check your output, press the View key.) When the HP e3000 spooler does not own the printer, these keys have their normal function.
Place the printer offline from the control panel, open the printer platen, and manually roll paper back and forth as required via the knob on the tractor shaft. To put the printer back into active service, close the platen, press CLEAR, and place back online. This procedure is safe at any time.

Place the printer offline from the control panel. Press and hold either the SHIFT+Up arrow or SHIFT+Down arrow to “micro-step” the paper up or down as needed. Place the printer back online.
The new function of the View key is invoked with a long depression of the View key. When the View key is pressed and held, paper will advance three complete forms, allowing tearoff at the rear of the printer. After advancing paper three forms for tearoff, placing the printer ONLINE will move paper downward two forms and printing will resume.
The native mode spooler on MPE/iX 5.5 (and later) supports Page Level Recovery (PLR). PLR provides the ability to restart printing at any page of a document due to device problems or a suspended spooler. (Refer to the HP e3000 MPE/iX Native Mode Spooler Reference Manual for more information.) Clarification on how it is handled for P5000LJ printers is described below.
There are three types of PLR that can occur, and all three use silent run techniques. That is, the data is sent to the printer and the printer interprets it but does not start actual printing until the printer reaches a target starting page specified by the spooler (e.g., the page following the last one printed).
Method 2

Restarting at a user-specified page number in a command
Processing of a spool file can be suspended and then resumed. It can be suspended by using the spooler command with the suspend parameter or by using the suspendspool command. It can be resumed with the spooler command with the resume parameter or by using the resumespool command. When the spool file resumes printing, it can start exactly where it left off or at another specified page.
For P5000LJ printers, the optional offset parameter in the spooler command can only be used to specify an absolute offset (i.e., absence of a + or – sign). When the offset parameter is not used, printing resumes where it stopped. When the offset parameter is used, a silent run (PLR) will occur up until the specified starting place.
For example, to suspend spooling and to position 7 pages from the beginning of the spool file, enter the following command:
In this case, the absence of a + or – sign indicates an absolute offset from the beginning of the spool file.
Because P5000LJ printers are typically connected to the network with the NIC, many of the spooler commands (e.g., those described above) should be avoided for mid-file suspension. This is because of two reasons: 1) a great deal of data is buffered in the network process and must be completed, and, 2) the network connection can be dropped if the printer is ready to receive data but no data is being sent. (Refer to the HP e3000 MPE/iX Native Mode Spooler Reference Manual.)
When a device exception occurs, this is an unexpected recovery situation. A device exception includes things such as paper jams, load paper error, etc.
Assume that the P5000LJ printer is connected to the network with the NIC. In order for PLR (silent run) to take place after a device exception and without specifying spooler commands to restart, the printer must be power cycled (e.g., after the jam). This is different from the way it may work with other HP printers that support PLR and use an “internal” JetDirect interface. This is also different from the way it works with the C256X printers that use the HP-IB interface. This caveat may be one of the reasons it appears that PLR does not work for P5000LJ printers. Note that printing will start with the page following the last one printed.
spooler 6;suspend;offset=7

MPE-XL / MPE / iX Typical Configuration
Restarting at the point of interruption when a particular spool file is reprinted after being interrupted previously by a command
In this case, a spool file is reprinted after being interrupted by a command such as spoolf #0 nnn;defer. For P5000LJ printers, when the spool file is undeferred, after being interrupted with the deferred option, a silent run (PLR) will occur up until the page following the last one printed.
A spool file can also be interrupted with the spooler ldev; stop command, but this command should be avoided for a P5000LJ printer connected to the network with the NIC. This is due to network printing problems with stopping mid-file server.
Within NMMGR follow the menu: Open Config DTS Go to Profiles Add or Modify Printer Type [22] (21, 22, or 26) or Printer Type File Name Line Speed [9600] (300 through 38400) Record Width [132] (1 . . . 2048 bytes) Modem Type [0] (0-None, 1-US, 2-Europe) Parity [NONE] (None, Even, Odd, 0's, 1's) Initially Spooled [Y] (Y,N) Device Class . . . user's choice Save Data Prior Screen . . . twice Go to DTC Config Card Assign Profile to LDEV Save Data Validate Link/DTX

After successful Validation, run SYSGEN to cross-validate the DTS configuration with the system configuration. In order for any TIO changes to take effect, you must reboot the system.
Within SYSGEN sysgen> io io> LD io> HO sysgen> K . . . (Keep configuration)

Overview
This chapter details a complete Windows configuration setup including:
The NIC supports network printing under Windows environments by using TCP/IP. In a Windows NT setup, pure TCP/IP is used as the network protocol whereas with Windows 95 or Windows 98, NetBIOS over TCP/IP is used.
Figure 15 shows two of the most common Windows setups you will see with the NIC. The ideal configuration is a network printer defined on the NT server to be shared by Windows 95 clients. However, any Windows station can also go directly to the NIC.



The IP address and subnet mask are mandatory TCP/IP settings and are needed before the print server can be detected on the network. There are also additional optional settings. This section offers alternative methods for configuring your NIC in a Windows environment and mentions some of the more common optional settings available.
Since TCP/IP is used for Windows printing, the NIC must be configured with a minimum of an IP address and subnet mask before it can be seen on the network.
Additional settings, like routing entries, can be configured. This allows communication across subnets when no other router exists.
Configuration of the NIC can be done from the printer control panel, Web browser, or host commands.

Since Windows environments rely on TCP/IP to communicate with the NIC, crossing routers becomes an issue.
After following one of the NIC configuration methods mentioned, you should be able to communicate only with the print server from the same subnet. This means any hosts across a router will not see your NIC. In order for hosts across a router to see your NIC, store a default router/gateway within the print server so that any packets destined for another subnet get forwarded to this router automatically. The router (or series of routers) can then take over ensuring the packets get to their final destination on another subnet on your network.
To configure a default router/gateway within the NIC:
Windows environments define groups of related computers as “workgroups.” By default, the NIC belongs to the workgroup called WORKGROUP. However, you may want to change this to suit your network better. To do this:
Communicating Across Routers

When defining some printers within Windows environments, the NIC requires that you specify a pre-defined destination rather than any name you would like. For example, when creating a new printer under Windows NT, you are presented with a screen similar to Figure 16.

Figure 16. Windows NT Print Setup Dialogue Box
The first field requires the IP address for the NIC and the second field must be filled in with a valid destination from the print server (e.g., d1prn). Otherwise, LPR will not be able to access the printer. Table 15 outlines the default destinations to choose from.
Table 15. NIC Default Destinations
Destination Mapped I/O Port
This name can be changed to something more meaningful using the built-in HTML forms. To do this:

Windows NT 3.51 Host Setup
This section covers Windows NT, Windows 95, and Windows 3.1 new printer setups.
To configure a new printer on a Windows NT 3.51 station:

Figure 17. Create a Printer Dialogue Box


Figure 18. Add LPR Compatible Printer Dialogue Box
You now have a new network printer which relies on the standard TCP/IP print protocol, LPD, to print remotely to a printer with the NIC.
This installation procedure assumes that the NIC adapter is configured with the correct IP address, subnet mask, and gateway (if required). In addition, the administrator can “ping” and telnet to the NIC adapter from the server console.
If this is not the case, use the printer front panel to configure the NIC adapter before proceeding.

Windows NT 4.0 Host Setup





and must be lowercase by default. You will probably use d1prn.

Windows NT 4.0 Host Setup





Printronix P5000LJ · Printronix P5000LJ

Windows NT 4.0 Host Setup


Printronix P5000LJ

Windows 95/98/ME Host Setup
To configure a new printer on a Windows 95 station:
Windows may ask for a disk or CD-ROM to load the appropriate printer driver to complete this new printer setup.
There should now be a new printer icon within the Printers folder. This new network printer relies on NetBIOS over TCP/IP as the underlying protocol to print to the NIC.

Windows 3.1 Host Setup
If you are running Windows 3.1 stations on your network, you will need to rely on either TCP/IP or IPX to print to the NIC. If IPX is used, you will have a print queue defined on a Novell file server to which your Windows 3.1 stations will send their print jobs. The NIC will then service this print queue as either a PSERVER or an RPRINTER. Please see Chapter 11, “Novell Configuration” for additional details.
If you want to rely on TCP/IP, you will need a third party TCP stack loaded onto your Windows station since TCP/IP support did not automatically come with Windows until the introduction of Windows NT and Windows 95. You may also be running a third party stack if you decided not to use a Microsoft operating system.
Some common TCP stacks are FTP Software's OnNet, NetManager's Chameleon, and Frontier Technologies' SuperTCP. In each case, they allow your Windows 3.1 station to communicate with other TCP/IP devices. This means you can send print jobs to the NIC as well.
The most common print method offered with Windows TCP stacks is LPR/ LPD, a multi-platform remote printing protocol used on everything from PCs to mainframes. The LPR print setup is very simplistic, involving only two parameters:
This section provides information on possible solutions to some standard configuration errors. If you require technical support, please have as much of the following information as you can available when you call:
Please follow these tips to determine what the problem may be with your NIC configuration.

NIC Cannot Be Found On The Network

Cannot Browse The NIC On The Network
If you can ping the printer from a workstation, but you cannot Web browse, Telnet, or print to the printer through the NIC, there may be an incorrect entry in the TCP access list. In order for this workstation to use the NIC in this case, one of two things must happen:
To view the current access list, use the printer control panel to access the configuration menu (see Chapter 4 for configuration menu information). From the DIAGNOSTICS/Printer Tests menu choose the E-Net Test Page. When the page prints, look under the “TCP ACCESS TABLE” section for the TCP access list entries.
To add or delete a TCP access list entry, refer to “TCP Access Lists” on page 261.

To reset all TCP/IP values to the factory defaults when access is impossible:
If you are still experiencing difficulty accessing or browsing the printer, contact technical support.

In some cases you may not be able to browse the printer web page simply because the NIC HTTP may be turned off.
If you cannot ping the NIC IP address, make sure the IP Address, subnet mask, and default gateway are set correctly by checking the Ethernet Parameters menu from the operator panel. See Chapter 4 for configuration menu information.
If you can ping the NIC IP address but cannot access the web pages, perform the following procedure to verify the NIC HTTP is turned on.
If you are still experiencing difficulty accessing or browsing the printer, contact technical support.
The installation procedure covered earlier in this chapter assumes that the NIC adapter is configured with the correct IP address, subnet mask and gateway (if required), and that the administrator can ping and telnet to the NIC adapter from the server console. If this is not the case, use the printer front panel to configure the NIC adapter before proceeding.
The NIC installation for Windows NT 4.0 or 2000 also requires “Microsoft TCP/IP Printing” service on the server. To install this service, click on the Network icon in the Control Panel and click on the “Services” tab. Click on “Add Service” and select “Microsoft TCP/IP printing.” • Are you logged in as the “Administrator”?
This installation requires administrator privileges. • “LPR port” is not listed in step 6.
Cancel the installation and install Microsoft TCP/IP printing service on the server. • LPR configuration warning during step 7.
Web Browser/HTTP Problem


The Ethernet cable is not plugged in, or the printer is not turned on. This message is a communication failure between the NT 2000 server and the NIC. Check cabling, IP address settings, gateway, etc. • Test page does not print or prints incorrectly.

Overview
This chapter details a complete Unix setup including:


The NIC supports network printing under various TCP/IP environments including all variations of Unix. Printing can come from multiple hosts directly or through central spooling machines. Figure 19 illustrates this.


There are mandatory settings needed before the print server can be detected on the network, as well as some additional optional settings. This section offers alternative methods for configuring your NIC and mentions some of the more common optional settings available.
The NIC must be assigned TCP/IP values of IP Address, Subnet Mask, and Gateway Value (if required) before setting up and establishing print queues and logical Unix printers. Refer to Chapter 7, “TCP/IP Configuration” for more information.
Additionally, the file “etc/hosts” on the Unix system (or the DNS server known to the Unix workstation being set up) must be updated to include the IP Address and logical name for the NIC, or a DNS server needs to be set with this information so that the Unix print daemons (software processes) can communicate with the physical NIC.
Additional settings, like routing entries, can be configured allowing for communication across subnets.
Configuration of the NIC can be done from the control panel or through host commands.
Since Unix environments rely on TCP/IP to communicate with the NIC, attention must be paid to routing.
After following one of the NIC configuration methods mentioned (other than the BOOTP method), you will most likely only be able to communicate with the print server from the same subnet. This means any host across a router will not be able to see your NIC. In order to communicate across a router, it is possible to store a static default router/gateway within the print server so that any packets destined for another subnet get forwarded to this router automatically. The router (or series of routers) can then take over ensuring the packets get to their final destination on another subnet on your network.
To configure a default router/gateway within the NIC:
Mandatory

There may be times when you would prefer to or have to perform the manual setup steps for a new printer definition. There may also be times when you require a less common print solution such as direct socket capabilities. This section covers these additional setups.
A simple way to set up printing on HP-UX is using SAM, the system administration tool.
a. For Printer Name, enter anything you want. This is actually the Unix Queue name, for example, “Accounting.”
b. For Remote System Name, enter the DNS/pingable name, for example, “MyP5000LJ.”
c. For Remote Printer Name, enter a dest on the P5000LJ, for example, “d1prn.”
d. Accept defaults for Remote Cancel model and Remote Status model.
e. Check the box next to “Remote Printer is on a BSD system.”
f. Click on OK.

Printing Setup On HP-UX
The following procedure requires root privilege.
Explanation of command line: -m indicates the model rmodel is to be associated with Quality -v indicates the use of /dev/null as a file interlock to avoid contention -orm is the name of remote Print Server -orp is the name of the remote printer on the remote Print Server -ob3 declares that the remote Print Server is a BSD type
Other useful commands are lpstat and lpmove [ /usr/lib ]
Printers set up on HP-PB & CIO computers:
Table 16. Drivers Required
Interface HP-PB CIO 6 CHANNEL
MUX
MUX
Serial mux2 mux0,cio_ca0 mux0_16,cio,ca0
Parallel lpr2 N/A N/A
The Drivers shown in this table should be installed in the Kernel Configuration.

HP-UX Configuration Guidelines
Within SAM follow the menu:
Printers and Plotters Printers/Plotters Printer/Plotter Manager menu ... select Actions Add Local Printer/Plotter
Add parallel Printer/Plotter or Add serial Printer/Plotter
If parallel printer is selected:
Printer Name user's choice Printer Model Interface user's choice Printer Device File Name SAM creates a special file Printer Class user's choice
If serial printer is selected:
The system displays the Serial Interface Hardware Paths Port select a valid port Printer Name user's choice Printer Model Interface user's choice Printer Device File Name SAM creates a special file Printer Class user's choice
This setup involves any Unix operating system using System V print spooling (e.g., SCO, Solaris, DG/UX, Sun 2.5.x, 2.6, 2.7 and similar, etc.). This means an interface file is used for each defined printer and in the case of any System V print setup involving a NIC, the RSHD protocol is used to transfer data from the host to the print server.
To manually configure a new System V printer on a Unix station, create a dummy device file that acts as a locking mechanism between contending print jobs.
Sys V printing is characterized by use of the lp printer interface program, lpsched printer scheduler, and the use of an interface file. The file lpadmin is used in setting up the print queue definition. As of Sun 2.6 and on, the interface file netstandard is provided in a generic interface file intended for network print servers such as the NIC. Also as of Sun 2.6 the ability to print to a socket (sometimes called raw tcp) or a remote printer (dest for P5000LJ) is provided.
Root access is required to use lpshut (stop the print scheduler to add a new printer with lpadmin), lpsched and lpadmin.
For the following example, assume the print queue to be created is lobby, and the ping-able IP Address name of the P5000LJ is LJ_PS1, and you wish to print to remote printer (dest) d1prn on LJ_PS1. As always with Unix, commands are case-sensitive. Also, be sure to use the bourne or korn shell, not the cshell when using the commands.

Printing Setup On Sys V
The command structure:
- stop print scheduler - use lpadmin to describe print queue (often referred to as the
logical Unix printer of the same name) - start the print scheduler - enable the print queue - accept the print queue (allow it to accept print jobs) - do a test print
Several examples are shown below.
lpshut lpsystem -t bsd lobby lpadmn -p lobby -v/dev/null (gives file locking) lpadmin -p lobby -i/usr/lib/lp/model/netstandard lpadmin -p lobby -sLJ_PS1!d1prn lpsched enable lobby accept lobby
lpshut lpadmn -p lobby -v/dev/null (gives file locking) lpadmin -p lobby -i/usr/lib/lp/model/netstandard -o protocol=bsd lpadmin -p lobby -sLJ_PS1!d1prn lpsched enable lobby accept lobby
lpshut lpadmn -p lobby -v/dev/null (gives file locking) lpadmin -p lobby -i/usr/lib/lp/model/netstandard lpadmin -p lobby -o dest=LJ_PS1:9100 -o protocol=tcp lpsched enable lobby accept lobby
To do a test print for either form using the /etc/hosts file:
lp -d lobby /etc/hosts

LPR/LPD Printing Setup On BSD Systems (Sun 4.x, DEC‚ Ultrix‚, Free BSD, etc.)
NIC also supports Unix operating systems which follow a BSD print system (e.g., SunOS 4.1.x). This means a printcap file is used to define all printers available on the host and interface scripts are not commonly used. Instead, LPR/LPD printers are defined.
To manually configure an LPR/LPD printer on a BSD Unix system:
Syntax:
printername::sh:pw#80:mx#0:\ :rm=P5000LJname:\ :rp=P5000LJdestination:\ :lp=:\ :sd=/usr/spool/lpd/printername:\ :lf=/usr/spool/lpd/printername/log:\ :af=/usr/spool/lpd/printername/acct:
where printername is any name you would like to give to this new printer, P5000LJname is the host or IP name of the print server, and P5000LJdestination is one of the pre-defined destinations/queues on the device.
Example:
1000Q: :sh:pw#80:mx#0:\ :rm=spike:\ :rp=d1prn:\ :lp=:\ :sd=/usr/spool/lpd/ 1000Q:\ :lf=/usr/spool/lpd/ 1000Q/log:\ :af=/usr/spool/lpd/ 1000Q/acct:
Example:
touch /usr/spool/lpd/1000Q/log touch /usr/spool/lpd/1000Q/acct

Example:
You now have a new printer which relies on LPR/LPD to print to a NIC. Use the following command to test printing:
Syntax:
Example:
NIC contains four logical printers (destinations) labeled as d1prn through d4prn. For FTP printing, establish an FTP session, followed by a put to the dest. Since the printer emulation can be PCL-II, Epson, or Proprinter, be sure the file you put to print is both printable and suitable for the printer emulation. Straight text is usable in all cases.
Example:
Type the commands as shown, followed by the enter key. Assume the file you want to print is /etc/inetd.conf, which is a simple text file.
ftp MyP5000LJ (MyP5000LJ needs to be a ping-able DNS name, or if no DNS, in the local /etc/hosts file, or it can be a dotted IP Address for the NIC) at the user prompt, type root at the password prompt, press ENTER (default password for root is blank until you change it) cd dest/d1prn put /etc/inetd.conf quit
The NIC is BSD capable, and has an internal lp daemon. Each Unix system has a remote shell function which can be used to access this process: Sun, etc. is rsh; UX is remsh; AIX is rcmd.
For example, printing the file /etc/inetd.conf on an HP-UX system to the second logical dest in the NIC: remsh MyP5000LJ lp -d d2prn < /etc/indetd.conf
You may also use this form: cat /etc/inetd.conf | remsh MyP5000LJ lp -d d2prn
In this form of printing the printer status will be fed back as to on/off line.

Unix Troubleshooting Tips
This section provides information on possible solutions to some standard configuration errors. If you require technical support, please have the following information (or as much as possible) when you call:
Please follow these tips to determine what the problem may be with your NIC configuration.

Stair-stepped output is print which starts at the top left of the page but every line thereafter starts a little further over to the right. It also refers to Unix jobs that print one line of text at the top of a page followed by a series of blank pages.
This kind of output happens only with Unix text jobs if carriage return insertion is not incorporated into the print setup. The printer may be told to do a linefeed but the Unix job does not specify anything about a carriage return to follow this.
To fix this, carriage return insertion must be enabled somewhere in the print setup. The easiest and most common location is on the NIC itself within the appropriate model. The feature is called onlcr and the command syntax is: set model modelname stty onlcr
For example, if printing to the destination d1prn, the associated model is m1. Therefore, the command is:
set model m1 stty onlcr save
Unix text jobs may also have problems outputting the last page of a job especially when the BSD Remote (LPD) print method is used. This means the form feed button has to be pressed on the printer to get this last page out.
To make this process automatic, tell the NIC to handle this task by setting this feature “on” in the appropriate model. The command syntax is:
set model modelname trailer $FF
For example, if printing to the destination d2prn, the associated model is m2. Therefore, the command is: set model m2 trailer $FF
For default destination model mappings of the NIC, please see “NIC Naming Schemes” on page 264.
Stair-stepped Output


Overview
This chapter details a complete Novell setup, including:
See Chapter 12, “Novell Configuration For 10/100Base-T Interfaces” for information about additional options available with the 10/100 Base-T interface.


The NIC card supports network printing under Novell environments by using IPX. It supports all 3.1X versions of NetWare. Figure 20 provides a Novell setup overview. Version 4.1X is supported under bindery emulation only.

Under all Novell environments, the NIC card does not require any network settings to make it visible on the network. Simply plug it in to your network and power it on. However, with a new print queue setup on a Novell file server, there can be some mandatory settings needed on the NIC.
NetWare Workstation

See Chapter 12, “Novell Configuration For 10/100Base-T Interfaces” for additional information about these options.
When defining a new print queue on a Novell file server, a new print server must be defined to represent the NIC. This name must match the pre-defined name given to the print server. By default, this name is in the format M_xxxxxx where xxxxxx equals the last six digits of the NIC address found on a configuration printout or control panel settings under Ethernet parameters, MAC Address (e.g., M_071C1A)
To use the HTML forms to define a print queue, do the following:
Syntax:
store pserver name newname
Example to change the name to micro1:
store pserver name micro1
Using HTML Forms

Under all versions of NetWare, both PSERVER and RPRINTER setups are supported by the NIC. Since a PSERVER setup is the most common, you will find the necessary steps to configure the NIC as a PSERVER shown first. Configuration for RPRINTER and NPRINTER setup follow the PSERVER information.
To configure a print queue on a NetWare 3.1x network:

NetWare Version 3.x PSERVER Setup
At this point, the NIC name (e.g., M_071C1A) should show within this window. This means the NIC knows about this new Novell print queue it must service as a PSERVER. Therefore, it will poll this queue regularly looking for jobs to print.

NetWare Version 3.x RPRINTER Setup
These steps are for Novell environments with Netware 3.x (or earlier) file servers.
To configure a new RPRINTER on a NetWare 3.x network:
If you have TCP/IP available and this print server already has an IP address stored within it, you can use the built-in HTML configuration forms or a Telnet session. Please see “Configuration Alternatives” on page 69 for additional details. If you have only Novell available, you will need to use a PC, laptop, or terminal.
Syntax:
store rprinter add PSERVERname printernumber P5000LJdestination
Example for an RPRINTER servicing printer 0 of the PSERVER.NLM called pserver1 and sending jobs to the NIC destination d1prn:
store rprinter add pserver1 0 d1prn

NetWare Version 4.x and 5.x PSERVER Setup
At this point, the NIC knows to receive any jobs this PSERVER.NLM has to send to it through the defined printer.
NIC destinations are case sensitive and will not be recognized if they are typed incorrectly. By default, they are all lower case. If you are setting up a NetWare 4 or 5 environment, the destination must be renamed to uppercase to match the PCONSOLE entry.
Following a PSERVER setup, bindery emulation is required. To configure the NIC as a PSERVER in a NetWare 4 environment:

Even though the entire print set up is done through PCONSOLE, you may want to communicate directly with the print server in order to modify settings, monitor the unit, etc. To communicate with the print server, the optional host software, npsh.exe, may be used. npsh.exe is a DOS executable program that can be run from a DOS prompt on a NetWare workstation. npsh.exe performs the following:
npsh nvplist Lists all of the NIC devices on the network; each name is in the default format M_xxxxxx (where xxxxxx equals the last six digits of the unit Ethernet address). This is regardless of whether it is configured as a PSERVER or an RPRINTER.
npsh unitname Starts a Telnet-like session with the named print server, allowing you to configure, monitor, and troubleshoot the unit with the built-in command set.
npsh unitname command Initiates a single Command with guest access only to the unit instead of entering into a complete session.

NetWare Version 4.x and 5.x RPRINTER Setup
To communicate with the unit using npsh.exe:
a. From a DOS prompt on a Novell workstation, begin an npsh session with the unit.
Starts a Telnet-like session with the named print server with guest access only.
b. To obtain root access to the unit, type:
A standard login screen is displayed prompting you for the login name and password.
c. Login to the unit as root user.
Root users require the use of a password as configured in the unit user list.
d. Enter the password. If this password is not yet set, press enter at the password prompt. Otherwise, enter the password that is already stored in the unit.
You are now logged in to the unit as a root user and can access any npsh command on the unit.
NIC can be configured to service both RPRINTER, NDS mode, and PSERVER, bindery mode.
Use the following procedure to set up an RPRINTER form of attachment on a 4.x or 5.x server:
1. NIC requires a bindery server login on the 4.x or 5.x as the first step to servicing RPRINTER. This bindery login is necessary for registering the NIC PSERVER name; no bindery queues or printers are set up. Using PCONSOLE, bindery mode, create a bindery printer server object whose name matches that of the NIC at the root context of the 4.x or 5.x box (i.e., M_03092B). After creating the bindery PrintServer on the 4.x or 5.x server, reboot NIC and use the debug Novell pserver command via a Telnet or npsh session, or print the E-Net Test Page out to make sure there is a successful server login.
a. create an NDS queue (any name you want), or simply use an existing one;
b. create a print server to use (any valid name, or choose one already in existence);

c. create a printer object to use with the print server object you chose or created, and attach it to the chosen queue;
Example:
If you are successful the print server console screen will show a “printer status” option. In the “printer status” window, note the numbers assigned to the printers you created. Assume for our example that one printer previously existed (number 0), and we are adding two more, whose numbers became 1, and 2.
On the load command you must strictly follow case of the name (this is not required on the NIC).
store rprinter add Fin_Q 1 d1prn
This command assigns destination d1prn as the RPRINTER 1 service path.
store rprinter add Fin_Q 2 d4prn
This command assigns destination d4prn as the RPRINTER 2 service path.
For NIC entries, case does not have to be observed. Also, if you want to change the destination names from dxprn, do so first with the set dest dest name new name command, being sure to use the save command so these reappear after a reboot.

NetWare 3.x - No PSERVER Connection
This section provides information on possible solutions to some standard configuration errors. If you require technical support, please have as much of the following information available when you call:
Please follow these tips to determine what the problem may be with your NIC configuration.


Overview
This chapter provides additional information for Novell environments using the 10/100Base-T interface, including:
There are no mandatory Novell settings needed before the print server can be detected on the network. However, there can be some mandatory settings needed before a Novell print queue can be serviced by the NIC. These mandatory settings are covered separately for Netware 3.x, 4.x, and 5.x under the Host Configuration heading.
The print server setup in a Novell environment is much simpler than that required in a TCP/IP one. No addresses, masks, or router entries are necessary, and, in most cases, the NIC can simply be connected to the network, turned on, and then configured for printing from a Novell station through PCONSOLE or Netware Administrator. See Figure 21 for an example of a Novell network which shows the use of file servers and how they relate to the print server.
There are, however, some optional parameters you may wish to change such as the preferred file server(s), print server password, polling time, frame type, print server name, NDS context, and NDS preferred tree. The following sections describe these optional parameters.


NetWare 4.1 File Server
NetWare 4.1 File Server
Figure 21. Novell Integration
In a bindery setup, the preferred file server specifies the file server that the print server object was created on. In an NDS setup, it specifies a file server that the print server object resides on. Since NDS is distributed, most administrators will not know which file server(s) the print server object is actually stored on, so in most NDS environments this option is not used. This feature is useful in a large Novell network so that the NIC does not ignore important file servers. If you are setting up the NIC to work with a Bindery file server, it is a good idea to set a preferred server on the NIC.
To view those file servers that the NIC does acknowledge at a given time, use the debug nest fserver command. See Chapter 13, “Commands” for more information.

Preferred File Server (NDS & Bindery)
HTML Method

Removing Preferred File Server
HTML Method

Setting Password Security (NDS & Bindery)
In addition to the general security measures, a Novell setup provides further password security. A password can be set on the NIC and within your PCONSOLE or Netware Administrator setup so that when the NIC tries to login to the file server, the passwords are compared.
To set the password on the Novell host for use in a PSERVER setup, you will need to complete the steps as follows.

You can set the poll time the NIC will use when checking for new jobs under a PSERVER setup. To do this, complete the following steps.

Changing The Print Server Name (NDS & Bindery)
When defining a new print queue on a Novell file server, a new print server must be defined to represent the NIC. This name must match the pre-defined name given to the print server. By default, this name is in the format M_xxxxxx where xxxxxx equals the last six digits of the NIC’s Ethernet address found on the bottom of the device (e.g., M_091C1A). You must make sure that the print server object that you are using for your PSERVER setup has the same name as that stored on the NIC. If you need to rename the print server object in Netware Administrator, please delete the object and re-create it with the new name. Netware administrator seems to have some problems with renaming objects.


Changing The Frame Type (NDS & Bindery)
The NIC allows the user to store a particular frame type for the unit to adhere to in a Novell environment.

Changing The Print Server Mode (NDS & Bindery)
The NIC allows the user to store a particular mode for the unit to operate in. This will be either NDS, Bindery, or autosense. If autosense is used, the NIC will first attempt to log in to a NDS file server, and, if it fails, it will try to log in to a Bindery file server.

Setting The NIC Context (NDS)
The NIC allows you to store the print server object in any context within the NDS tree you choose. By default, the NIC will look for the print server object in the same context as the file server object it connects to is stored in.

Setting The Print Server Preferred NDS Tree (NDS)
The NIC supports Novell environments that have multiple trees. If your environment has more than one tree, you may want to set a preferred tree. By default, the NIC will try to log in to each tree it finds until it is successful.

NDS PSERVER Setup (Netware 4.x and 5.x)
This section covers PSERVER and RPRINTER/NPRINTER setups on the NIC. The NIC can handle up to eight RPRINTER/NPPRINTER setups.
Although the entire print setup is done through Netware Administrator or PCONSOLE, you may need to communicate directly with the print server in order to modify settings, monitor the unit, etc.
For Netware 4.x environments, you can obtain a NWAdmn3x snap-in program called MPAdmin. This snap-in can be used to configure PSERVER setups as well as additional settings on the NIC.
There are a number of ways to configure the NIC for use in a Novell NDS PSERVER setup. These include using the MPAdmin snap-in for Netware Administrator, using generic print server objects in Netware Administrator, or by using PCONSOLE. The following steps describe a setup using generic print server object in Netware Administrator. Setups using PCONSOLE are less common and will not be discussed.
To create a printer/print queue in an NDS environment using Netware Administrator print server objects, you need to complete the following steps:

In NDS, a printer object can only be attached to one print server object at a time, as Novell is using the printer object to represent a physical printer. A physical printer can only be attached to one parallel or serial port at a time. Thus, if you assign a printer object to another print server object, the new print server object will “steal” it from the old one (this also happens with non-NIC print server objects).
To properly process print jobs sent to the NIC, the printer object created in Novell must refer to the destination on this server and not to the actual physical printer. On the NIC, print jobs must pass through an extra layer (a “destination”) before being sent on to the printer. This destination allows for further processing of the print job before sending it to the printer.
If you are using multiple print servers, you will have to either rename all your destinations to ensure that no printer object names conflict or keep all the printer objects for one print server in a different context than those for the other print server.

Bindery PSERVER Setup (Netware 3.x, 4.x, and 5.x)
A Bindery PSERVER setup is possible under Netware 3.x, Netware 4.x and Netware 5.x. If you are using Netware 4.x or 5.x, Bindery emulation is required. Please consult your Novell manual on how to set up Bindery emulation. A Bindery setup using PCONSOLE in Netware 3.x is described in “NetWare Version 3.x RPRINTER Setup” on page 210. The setup using PCONSOLE in Netware 4.x is described in “NetWare Version 4.x and 5.x RPRINTER Setup” on page 213.
To reference a Bindery queue when you perform your PSERVER setup in NDS, you create a PSERVER object for the NIC on the file server where the Bindery queue resides. This is important because to service the queue, the NIC must log on to the queue’s file server. Since the queue is not an NDS queue, the NIC cannot log in under NDS, so it must log in under Bindery.
This only works if there is a valid PSERVER object on the file server. This PSERVER object must have the same name that was used for the NDS setup. By default, this will be “M_xxxxxx” where “xxxxxx” equals the last six digits of the print server’s Ethernet address found on the bottom of the device (e.g., M_091C1A). This PSERVER object does not need to have any printers or queues assigned to it. Also, when referencing a Bindery queue in NDS, the Novell Mode on the NIC must be set to “auto” so that both NDS and Bindery logins are possible. See “Setting The NIC Context (NDS)” on page 227.

RPRINTER/NPRINTER Setup (Netware 3.x, 4.x, and 5.x)
This procedure associates an existing PSERVER with a remote NIC acting as a RPRINTER/NPRINTER in a NetWare 3.x or Netware 4.x or Netware 5.x environment. It is the PSERVER’s responsibility to get jobs from the queue and to pass them off to the NIC acting as the remote printer. Unlike a PSERVER setup, the NIC does not deal directly with the queues.
The following steps assume that you have created a PSERVER object in either Netware 3.x or Netware 4.x or Netware 5.x and have assigned printers and queues to it. If you have not already done this, do it now. The setup is similar to creating a PSERVER setup for the NIC, except that there are no restrictions about which names you may use for the print server and printer objects.

RPRINTER/NPRINTER Setup (Netware 3.x, 4.x, and 5.x)

Example for an RPRINTER servicing printer 0 of the PSERVER.NLM called pserver1 and sending jobs to the NIC destination d1prn: store rprinter add pserver1 0 d1prn
Wait two minutes and then check your PSERVER to see if the appropriate printer is being serviced. The printer should display a message such as “Waiting for job.” At this point, the NIC knows to receive any jobs this PSERVER.NLM has to send to it through the defined printer.
In 1998, Novell released a new printing system designed to make network administration of printers easier and more fully functional. This system is called Novell Distributed Print Services (NDPS), and can be used with Novell Netware 4.11 and above along with the supporting software on clients. This section gives high-level instructions to install and use NDPS with the printer. These instructions assume that you understand NDPS architecture well enough to be able to use these instructions along with Novell’s instructions to install the NIC into NDPS. See Novell’s documentation to better understand terms not defined here.
The drivers used with the P5000LJ printer can be automatically downloaded into a Windows machine when a NDPS printer is installed, if the driver is installed into the NDPS Broker Resource Management Service. See Novell’s documentation for more information.

RPRINTER/NPRINTER Setup (Netware 3.x, 4.x, and 5.x)
In this mode, an NDPS printer agent receives jobs from an NDPS client, then forwards these jobs to an existing Netware queue. The Netware queue would then be serviced by the NIC in some manner.
In this mode, an NDPS printer agent receives jobs from an NDPS client, then forwards these jobs to a printer using the LPR protocol.
available.
In this mode, an NDPS printer agent receives jobs from an NDPS client, then forwards these jobs to a printer using the RPRINTER IPX protocol.

The P5000LJ printer will need to be rebooted to attach to the NDPS printer agent in this mode.
If there is no connection with the NIC after you have completed the print setup, there are several things to confirm.

Note NIC destinations are case sensitive so they will not be recognized if they are typed incorrectly. By default, they are all in lowercase. If you are setting up in a NetWare 4.x environment, the destination must be renamed to uppercase to match the PCONSOLE or Netware Administrator entry. Please see set dest destination name newname on page 247 for information on changing names.
PSERVER Setup

If none of these solutions help your situation, you may want to try the whole setup again. Completely delete the setup that is giving you trouble and go through the setup again following each step carefully.

If there is no connection with the NIC after you have completed the print setup, there are several things to confirm.
RPRINTER/NPRINTER Setup

If none of these solutions help your situation, you may want to try the whole setup again. Completely delete the setup that is giving you trouble and go through the setup again following each step carefully.

If you have followed the suggestions above and are still having printing problems, try rebooting the NIC. Then either review every step you took when configuring the NIC, or try re-doing the setup, paying special attention to each step explained in “Novell Host Configuration” on page 208.
For additional information on these suggestions or on various Novell printing mechanisms, please refer to your NetWare User Manuals.
Printing Related


Command Shell Overview
The NIC comes with an in-depth command shell which allows you to manipulate objects like destinations, I/O ports, and models. Additionally, it provides you with monitoring and troubleshooting capabilities.
All configurable commands start with either store or set. Troubleshooting commands usually start with debug, and view commands start with list.
If the store prefix is used, the NIC must be repowered for the changes to take effect. Since store affects flash memory settings only, the print server must reset and read the new settings now in flash memory.
If the set prefix is used, a save command must also be executed so that the new settings are retained after power cycles. Since set only affects the settings in memory, they will be lost after a power cycle unless they are saved to flash memory.
The NIC command shell provides several online help tools. These include the following:
Typing ? when logged in to the command shell will produce a full listing of all commands available.

Command Prefixes
Typing in the first portion of a command will produce an error message showing the correct syntax. For example, typing in store tcpip will produce a list of all commands that start with this prefix.
This section outlines the entire NIC command set including the command syntax, a description, and, in most cases, an example for each command listed.
These commands change the settings stored in flash memory and do not affect the current or working settings in memory. A power cycle is needed before the stored settings become current.
store ifc ifnum utp [-]li [-]rx store ifc 1 utp li
Modify the physical UTP interface properties where li enables link integrity and rx enables the increased receive threshold. store ifc from default
Set all UTP settings back to factory defaults.
store ifc from current
Store all current UTP settings to flash memory so they are retained after a power cycle. This ensures all current settings match what is stored in flash memory. store pserver opts [[-]jobsecurity] [jobtimeout seconds] store pserver opts jobsecurity jobtimeout 5
If jobsecurity is disabled, any user can cancel queued jobs on the NIC including guest users. If jobtimeout is set to some value other than 0, the NIC will only wait this amount of seconds when getting printer feedback. This is only used if you have a logpath port and type set on a particular destination.
store pserver tcpsocket TCPportnumber port newTCPportnumber store pserver tcpsocket 4000 port 5000
Change a pre-defined TCPportnumber on the NIC to a newTCPportnumber. The default number is 9100 for prn.

store pserver tcpsocket TCPportnumber dest destination store pserver tcpsocket 5000 dest d1prn
Assign a pre-defined TCPportnumber to a particular destination on the NIC. Therefore, if you are using a print method that sends jobs directly to a TCP port number, you still have the option to process the job data through this destination setting.
store pserver novell passwd password store pserver novell passwd mplex
Store the password for the NIC to use when logging in to a Novell file server. This password would have to match one set on the file server.
store pserver novell user name username store pserver novell user name micro1
Define a username on the NIC to be used when it logs in to a Novell file server to find information. This username must match a user pre-defined on the Novell file server. store pserver novell user passwd password store pserver novell user passwd mplex2
Define a password on the NIC for the Novell user already defined. This password must match the one stored on the Novell file server. Passwords are optional as long as there is not one defined on the file server for the user. store pserver novell fserver add|del fileservername store pserver novell fserver add fs1
Add or remove a server entry on the NIC for the Novell file server it will be servicing. store pserver smb workgrp newworkgroupname store pserver smb workgrp eng
Define a different Windows workgroup as defined by newworkgroupname for the NIC to be visible within. By default, the print server only comes up within the group called “WORKGROUP.” store pserver from default
Set all general print server settings back to factory defaults. store pserver from current
Store all current general print server settings to flash memory so they are retained after a power cycle. This ensures all current settings match what is stored in flash memory.
store rprinter add|del printservername printernumber destination store rprinter add pserver1 0 d1prn
Add or delete the RPRINTER settings on the NIC for a Novell environment. The printservername must be the name of an existing PSERVER.NLM on your Novell file server. The printernumber is the printer number within this PSERVER.NLM. The destination is the queue on the NIC where the print jobs will be sent to.
store tcpip ifnum addr IPaddress store tcpip 1 addr 192.75.11.9
Store Commands

Store the IP address for the NIC.
store tcpip ifnum mask netmask store tcpip 1 mask 255.255.255.0
Store the subnet mask for the NIC.
store tcpip ifnum opts [[-]rarp] [[-]bootp] [[-]dhcp] store tcpip 1 opts -rarp -bootp -dhcp
Enable or disable the automatic RARP, BOOTP, or DHCP requests for IP addresses upon bootup. If you are storing the NIC TCP/IP network settings within the device, you will not need to rely on RARP, BOOTP, or DHCP for new settings.
store tcpip ifnum frametype [[-]ethernet2] [[-]802.2snap] store tcpip 1 frametype ethernet2 802.2snap
Control which frame type(s) is supported with the TCP/IP protocol. By default, both ethernet2 and 802.2snap are enabled but normal TCP/IP communications rely on Ethernet 2. This setting has no affect on other supported network protocols (e.g., Novell).
store tcpip route add|del host|net IPaddress ifnum store tcpip route add net 192.75.12.0 1 store tcpip route del net 192.75.12.9 1
Add or delete a static route to a particular TCP/IP host or subnet specified by IPaddress so the NIC knows how to communicate with it. Normally one entry for a default router/gateway is all that is needed for communications between different subnets. Please see the next command for details. store tcpip route add|del default routerIPaddress ifnum store tcpip route add default 192.75.11.1 1
Store a default router/gateway defined by routerIPaddress so the NIC knows where to direct packets destined for another subnet. It is easier to store one default entry rather than an entry per remote host or network as in the previous command. store tcpip tcp rxwin packets store tcpip tcp rxwin 2
Determine the receive window size for the NIC. Usually the packets value ranges from 2 to 8 with the lower number allowing for more simultaneous TCP connections with the print server. store tcpip tcp opts [-]keepalive [-]disbufmgmt store tcpip tcp opts keepalive -disbufmgmt
Control whether the NIC maintains a connection with a host when data cannot be accepted into its buffer. Normally the keepalive feature is enabled so when the printer can not accept data, the print job connection is maintained and continued once the situation clears. If disbufmgmt is disabled (i.e., “-”), the NIC will not buffer any data when there is a blocked situation with the printer. Normally it is best to have both keepalive and disbufmgmt enabled. store tcpip tcp access [root] add|del IPaddress

store tcpip tcp access add 192.75.11.25
Add or remove an entry from the NIC TCP access list defined by IPaddress. If the list has an entry, only this host can print to and remotely interact with the print server. store tcpip from default
Set all TCP/IP network settings back to factory defaults.
store tcpip from current
Store all current TCP/IP network settings to flash memory so they are retained after a power cycle. This ensures all current settings match what is stored in flash memory.
These settings alter the current or working settings in memory only. Therefore, they will be lost if the NIC is power cycled. To ensure this does not happen, be sure to issue a save command so the current settings get written to flash memory.
set date year month day set date 1997 02 10
Set the current date noting the four-digit year, the two-digit month from 01 through 12, and the day being the number in the month. If the NIC is reset, this value will be lost so you will need to set the date again. set dest destination name newname set dest d1prn name laser
Change the current name of the destination to a new name as indicated by newname. This newname must be nine characters or less or it will be truncated. These names are case sensitive. set dest destination backchannel prn [prn] set dest d1prn backchannel prn
Establish a return path for printer feedback for a given destination. Since the NIC I/O port is bi-directional, however, you will most likely use the same I/O port that the destination is currently sending jobs to. set dest destination model modelname set dest d1prn model m4
Associate a model with a destination. Jobs sent to the named destination are processed according to the options defined in the named model. set dest destination logpath logpathname set dest d1prn logpath l4
Associate a logpath with a destination. Jobs sent to the named destination are logged according to the settings defined in the named logpath. set dest destination service [[-]socket][[-]lpd] [[-]lpsched] [[-]rprinter] [[-]pserver] [[-]netbios] [[-]ftpd] set dest d1prn service -netbios
Set Commands

Set the destination to handle only certain print services. To add a service, specify the service name. To disable a service, use “-” before the name. The available services are:
socket Direct socket printing via TCP/IP.
lpd LPR printing with TCP/IP including LPR clients on any platform.
lpsched LP or System V printing with TCP/IP.
rprinter Novell RPRINTER support.
pserver Novell PSERVER support.
netbios Windows 95 and Windows for Workgroups printing.
ftpd Printing using the File Transfer Protocol (ftp) via TCP/IP.
set dest from default
Set all destination settings back to factory defaults. set dest from stored
Set all current destination settings to the values stored in flash memory. set logpath logpath name newname set logpath l1 name pagecount
Change the current name of the logpath to a new name as indicated by newname. This newname must be nine characters or less or it will be truncated. These names are case sensitive. set logpath logpath type [[-]job] [[-]user] [[-]pgcnt] [[-]cksum] [[-]printer] [[-]ioport] set logpath l2 type job user printer pgcnt
Establish the type of printer and print job logging to be done within this logpath. The options are:
job Job ID, username, etc.
user User ID along with three messages per job about start and finish.
pgcnt For total pages printed in a job.
cksum 16-bit checksum value to confirm integrity of data printed.
printer For special printer feedback.
ioport Printer error messages determined through the parallel port pins.

set logpath logpath port TCPportnumber| email|syslog set logpath l3 port 2000
Determine where the log information should be sent for a print job or attached printer. The choices are:
TCPportnumber TCP port number ranging from 1024 to 65000.
email Particular user's email address. This address is set using the set sysinfo email emailname@IPaddress command.
syslog A central TCP/IP host running the SYSLOG daemon. This host is set using the set sysinfo syslog IPaddress command.
set logpath from default
Set all logpath settings back to factory defaults. set logpath from stored
Set all current logpath settings to the values stored in flash memory.
set model model name newname set model m1 name landscape
Change the current name of the model to a new name as indicated by newname. This newname must be nine characters or less or it will be truncated. These names are case sensitive.
set model model type raw set model m2 type raw
Set the model type to raw so that it does not process the data passing through it in any way.
set model model banner [ps|text|auto [after]] set model m2 banner text
Determine whether a banner page should be added for print jobs passing through the model mapped destination/queue. auto will determine which type is needed depending on the type of print job data passing through. By default, banner pages are added to the front of the job. If after is set, the banner page will come at the end.
set model model stty [[-]onlcr] [[-]descramble] [xtab tablength|none] set model m3 stty onlcr
Control extra job processing done by the model. The processing options are:
onlcr Carriage return insertion for Unix text jobs. Adds carriage returns to text jobs with solitary linefeeds. This will prevent stair-stepped output or output running off the right side of the page.
descramble Automatic descrambling of print jobs passing through which have been scrambled using the proprietary scramble Unix utility, npscramble.
xtab Tab expansion from 1 to 16 spaces.
Set Commands

set model model trailer trailerstring set model m7 trailer $FF
Set a trailer string to be sent to the printer at the end of any print jobs passing through this model. trailerstring can consist of up to nine elements. An example element is a hexadecimal code (e.g., 0x04) or a pre-defined variable on the print server (e.g., $FF for a formfeed). Use list var to see all available variables.
set model from default
Set all model settings back to factory defaults. set model from stored
Set all current model settings to the values stored in flash memory.
set prn [-]autofd set prn -autofd
Assert or do not assert the AUTOFD line for carriage return insertion. This only affects printers that support this function (e.g., impact printers).
set prn flush set prn flush
Flush the data in the parallel port input and output buffers.
set prn unlock set prn unlock
Release the access lock on the parallel port.
set prn timeout minutes |none set prn timeout none
Terminate the print job sent to the parallel port if it is not printed after the timeout period in minutes expires. The minutes value ranges from 0 though 255 with 0 indicating no timing out to take place. This is the default setting and should be fine for most print setups.
set prn [-]opost set prn -opost
Allow or disallow output processing on the parallel port such as carriage return insertion (i.e., onlcr).
set prn [-]onlcr set prn -onlcr
Enable or disable carriage return insertion on the parallel port. This may be needed for Unix text jobs coming through with solitary linefeeds. This feature is almost always set at the model level rather than the I/O port level though.
set prn xtab tablength |none set prn xtab none
Set the tabstop width as indicated by tablength. The range is 1 through 16 spaces.
set prn from default
Set all parallel port settings back to factory defaults. set prn from stored
Set all current parallel port settings to the values stored in flash memory.

To add a user named snmp with root privileges, please follow the steps below:
The user snmp is now created and snmppassword is the only community string which will allow write access. set snmp manager index ipaddress trap-community
The Print Server continuously generates traps, but unless the trap table is filled in, no SNMP manager will receive this information. To set the Print Server to send traps to a particular SNMP manager, use this command to add an SNMP manager to the trap table.
index is the index number of the trap table. ipaddress is the IP address of the SNMP manager receiving traps. trap-community is the community string sent along with the trap information. set sysinfo name newname set sysinfo name salesprinter
Set a descriptive name defined by newname for NIC identification purposes. This is not used in the operation of the print server in any way. set sysinfo location description set sysinfo location salesdept
Set the physical location of the NIC. This is for identification purposes and is not used in the operation of the print server in any way. set sysinfo contact contactname set sysinfo contact Paul_Harris
Set a person or department to contact in case of print server trouble. set sysinfo loginfo [-]sys | [-]tcp | [-]ipx | [-]spx set sysinfo loginfo -sys ipx
Set the NIC debugging information type. Usually this information includes unexpected errors or exceptions from the print server divided into these groups:
sys General system messages.
tcp TCP stack messages.
ipx IPX stack messages.
spx SPX stack messages.
Set Commands · set snmp

set sysinfo logport null|syslog set sysinfo logport null
Define where the debugging information should be sent to. This can be sent to an output device off of the NIC I/O port or to a central TCP/IP host running a SYSLOG daemon. To set this host, use the command set sysinfo syslog hostIPaddress. set sysinfo email emailname@IPaddress set sysinfo email [email protected]
Define the user email address to receive printer and job logging information from a particular logpath on the NIC. emailname is the host or IP name of the user, and IPaddress is the IP address where the mail is stored on your network. set sysinfo syslog hostIPaddress set sysinfo syslog 192.75.11.30
Set the IP address of the host running the SYSLOG daemon. NIC debugging or print job and printer logging information can be sent to that IP address. set sysinfo dns DNSserverIPaddress set sysinfo dns 192.75.11.2
Set your DNS server IP address so the NIC can resolve host names when used with its built-in Telnet and Ping clients. set sysinfo descramblekey hexvalue set sysinfo descramblekey 1234
Set the key value used for descrambling print jobs that have passed through the npscramble utility on a TCP/IP host. This key is a four-digit hexadecimal value obtained from the host software, npscramble. Within the npscramble source code, there is a variable called SR_KEY which contains the default key value. This can be changed to any four-digit value you would like. set sysinfo module [[-]novell] [[-]netbios] set sysinfo module -novell
Enable and disable certain network protocol stacks within the NIC. Sometimes it helps to disable any protocols you are not using on your network. set time hours [minutes [seconds ]] set time 10 30
Set the current time noting the hours based on the 24-hour system and the minutes and seconds ranging from 0 through 59. If the NIC is reset, this value will be lost so you will need to set the time again.

set user add|del username set user add eng
Add or remove a user on the NIC defined by username.
set user passwd username password set user passwd eng mplex1
Assign a password to a defined user on the NIC. This password must be less than eleven characters. set user type username root|guest set user type eng root
Assign root or guest privileges to a particular user defined by username. Guest permissions allow viewing of settings only. Root permissions allow complete control of the NIC. set user from default
Set all user settings back to factory defaults. set user from stored
Set all current user settings to the values stored in flash memory.
set user passwd snmp com_name
Sets the new SNMP R/W community name as the com_name value. set var variablename variablestring set var LANDSCAPE 0x1b 0x26 0x6c 0x31 0x4f set var FINISH $FF $PCL-RST
Define a new variable to be used in header, trailer, or switch strings on the NIC and call it variablename. variablestring can be a space- separated list of words, hexadecimal numbers (e.g., 0x04), or references to other pre-defined variables. It is easiest to make up the variablestring with hexadecimal values as shown in the example.
One variable counts as one element within header and trailer strings.
Defined variables are referenced in strings by placing an $ before the variable name (e.g., set model m1 trailer $FF). set var from default
Set all variable settings back to factory defaults.
set var from stored
Set all current variable settings to the values stored in flash memory.
Set Commands

List Commands
These commands list the current or working settings for a particular section within the command shell. To view stored settings in flash memory, you will need to add in stored within the beginning of any of the following commands. For example, list prn shows you the current prn settings but list stored prn shows you the settings sitting in flash memory. Normally these should match.
List the current ARP table that the NIC adheres to in a TCP/IP network. list date
List the current date on the NIC.
List the current destination settings (e.g., names and mapped I/O ports, models, and logpaths). list diff
List the differences between the current settings and the stored settings in flash memory. Normally, you want these values to match, so issue a save command followed by a reset. list ifc
List the current UTP interface settings (e.g., link integrity).
List the license details and license key number. list logins
List any active user logins on the NIC. list logpath
List the current logpath settings (e.g., names and mapped destinations).
List the current model settings (e.g., names and mapped destinations). list pserver
List the current general print server settings (e.g., print server name and Novell mode). list prn
List the current parallel port setting (e.g., mode).
List any current RPRINTER definitions. list snmp
List Trap Table containing SNMP Managers.
List the current NIC system information (e.g., contact name and protocol stacks enabled).
List all current TCP/IP network settings (e.g., IP address and subnet mask).

List the status of output tests on the I/O ports. list time
List the current time on the NIC.
List the current user definitions (e.g., user names and types).
List all pre-defined variables including any newly created ones. Any of these defined variables can be referenced in a string by placing a $ before the variable name (e.g., set model m1 trailer $FF).
The debug set of commands help troubleshoot problems that may occur on the NIC. Some of the output may be cryptic, but it helps when troubleshooting.
List ROM contents.
List statistics from the I/O port module. debug ip
List IP stack statistics. debug lpd
List statistics from the lpd daemon.
List statistics from the queue module. debug mem
List statistics from the NIC memory module. debug nest fserver
View the Novell file server(s) the NIC has acknowledged and connected to.
Determine whether a board has been bound to the NIC under Novell and that the network number is correct for your network. debug nest logs
View miscellaneous Novell log messages.
Determine what frame type is bonded to which board number under Novell.
View the Novell PSERVER log messages including queues attached to. debug nest rprinter
View the Novell PSERVER and RPRINTER log messages and destinations used on the NIC.

Determine whether the NIC is seeing any Novell network activity. debug netbios
List NetBIOS (i.e., Windows 95 and WfW) statistics.
List network interface statistics.
List file and print servers. debug tcp
List TCP stack statistics.
These commands do not fall under any specific section of the command shell, but they are used quite frequently.
Save the current settings to flash memory so they are available after power cycles. Sysinfo, destination, model, logpath, variable, user, and I/O port settings will be saved. If default is specified as well, factory settings will be saved, overwriting any new settings you have configured. reset
Perform a warm boot or hardware reset simulating a power-on reset. Restores current settings to those stored in flash memory since the flash memory settings will be read and loaded into memory upon bootup. load [default]
Load the settings stored in flash memory and use them as the current or working settings. If default is specified as well, factory settings will be loaded.
lpstat [ioport] [jobID] lpstat prn
Display active and queued jobs and I/O port status for a given ioport or jobID. Specifying one of these parameters will shorten the output focusing on the particular I/O port or print job specified.
cancel jobID cancel d1prn-10
Remove a job from an I/O port queue. Use lpstat to find a particular job ID first.

start fox|tts|loopb prn start fox prn
Begin a debugging test on one of the I/O ports on the NIC. The tests available are:
fox A continuous stream of text sent to the attached printer. This is a good test for troubleshooting hardware as long as the attached printer supports text output.
tts A continuous stream of Gandalf 400C TTS-compatible text sent to the attached printer.
loopb Loopback test. Any input characters from the device attached to the I/O port is echoed back.
stop prn stop prn
Stop an output test on an I/O port. disable ioport|destination disable prn
Disable an ioport so that queued jobs are not printed, or disable a destination so jobs can not be queued to it. enable ioport|destination enable prn
Enable an ioport so that queued jobs are printed, or enable a destination so jobs can be queued to it. close tcp TCPindexnumber close tcp 3
Force a TCP/IP connection between a TCP/IP host and the NIC to close. The TCPindexnumber can be retrieved from “debug tcp” output. ping [-s] hostIPaddress [datasize [packetnumber]] ping 192.75.11.30 ping another TCP/IP host specified by hostIPaddress on the NIC network. datasize is the datagram packet size which defaults to 64 bytes if no size is included in the syntax, and packetnumber is the number of requests to be sent.
telnet hostIPaddress [escapecharacter] telnet 192.75.11.35
Start a Telnet session with another TCP/IP host specified by hostIPaddress on the NIC network. If escapecharacter is used, it resets the key sequence used to exit the Telnet session. It will return you to the telnet> prompt where you can execute quit. Use the keycode command to find out exact escape characters if needed. The default character is CTRL-].
Miscellaneous Commands

Echo string or redirect string to an I/O port using chr string > ioport. keycode
Determine the hexadecimal value for a key to be used as the escape character with the NIC built-in telnet command.
chr string

NIC Security
There are TCP access lists available to restrict host connections with the device.
By default, the NIC supports two logical user types:
root Access to everything within the print server including all configurable settings.
guest Ability to list settings only.
Using set commands, other users can be created.
Passwords can be set for each user type. However, most often you would just set a password for the root user to protect the NIC configuration. Guest users cannot alter the print server configuration in any way.
You can configure a root password on your NIC using either Telnet or a Web browser as follows:
Using Telnet, set a root password by entering the following commands.
Syntax:
set user passwd username password save
Example:
set user passwd root your_password_for_root save

Web Browser
From this point on, anytime you log in to the NIC as root, you will need to specify this password or your login attempt will fail.
To clear this password or change it, use the same “Administration Configuration” HTML form. Just enter the appropriate “Old” password and put in the new one (or nothing if you do not want a root password any longer). The commands directly on the NIC are: set user from default save
You will also have to restore all IP values.

Within TCP/IP environments, the NIC can restrict host access to destinations/ queues and remote command (i.e., rsh, rcmd, remsh and telnet) execution services. This is done using an access list similar in function to the Unix .rhosts file.
To view the current access list on the print server, complete the steps below.
If the TCP access table entry list is empty, all hosts have access to the NIC services. If there are entries in the list, only those hosts specified have access to printing and remote command execution.
To add and delete access list entries, the commands are:
Syntax:
store tcpip tcp access add|del hostIPaddress| networkaddress reset
where hostIPaddress is the IP address of a TCP/IP host on your network and networkaddress is the address of a subnet on your network.
Example: store tcpip tcp access add 192.75.11.25 store tcpip tcp access add 192.75.12.0 store tcpip tcp access del 192.75.11.25 reset
TCP Access Lists

Printer Monitoring And Logging
One of the key aspects of maintaining a computing environment is monitoring printer status and logging this information to useful places. The NIC allows this through its built-in HTML forms, command set, SNMP traps, e-mail alerts, and logpaths.
To view the current status of an I/O port on the NIC, you can use either Telnet or a Web browser as follows:
Using Telnet, enter the lpstat command directly on the print server (after you have logged in as guest or root).
Using a Web browser, select the desired I/O port on the “Status” HTML form that comes with theNIC:
http://P5000LJIPaddress/indexStatus.html (e.g., http://192.75.11.9/indexStatus.html).
Whether using Telnet or a Web browser, you are given a description of each I/O port status and a list of queued jobs. Table 17 describes some of the common terms you may encounter.
Table 17. Key Printer Logging Terms
idle There is no job queued for the NIC I/O port.
blocked The printer is not allowing the NIC to send data to it. If this condition persists, check that there is not a printer error and that the printer is online and ready to go.
waiting The NIC knows about a print job but is waiting for the host to send more data or to send an expected packet.
Term Description

Printer Logging Through Logpaths
Destinations are logical queues with associated models and logpaths. Models allow extra processing needed with the print jobs. Logpaths are used if logging is desired for each job.
Each logpath on the NIC consists of two parts:
Type The type of log information to be captured. The choices are job for job ID and username, user for user ID (and three messages per job), pgcnt for total pages printed in a job, cksum for file checksums, printer for special printer feedback, and ioport for parallel printer status messages.
Port Where this log information will be sent to. The choices are a TCP port number (e.g., 2000), an email address (including an alias), or a central host running a SYSLOG daemon.
To view the current logpath settings on the print server, you can use either Telnet or a Web browser as follows:
Using Telnet, type the commands and your variable data as shown in the example below:
Syntax: list logpath list logpath logpath set logpath logpath port ioport set logpath logpath type user job save
Example:
10.221.1.25:root> list logpath
NAME LOG PORT LOG FLAGS l1 - - l2 - - l3 - - l4 - - 10.221.1.25:root> list logpath l2
10.221.1.25:root> set logpath l2 port 9999
10.221.1.25:root> set logpath l2 type user job
ok · save

Whether using Telnet or a Web browser, you can alter any of these settings at this point and then click on the SUBMIT button to store them into the NIC. Remember to repower the NIC to make the settings take effect.
A single I/O Port destination can be configured with a variety of model and logpath combinations. For instance, once you set the parameters for m1 and l1, you can assign the model and logpath to more than one I/O port destination such as d1prn, d2prn, and d8prn. You may now use the same set of model and logpath parameters more than once without having to redefine those parameters each time for another I/O Port destination.

Overview
The printer interface is the point where the data line from the host computer plugs into the printer. The interface processes all communications signals and data to and from the host computer. It consists of a printed circuit board assembly (PCBA) and a connector for the data cable from the host computer. Communication signals and data may be sent over Ethernet, parallel, or serial lines.
When data is sent through multiple interfaces, the Autoport Switching feature forces the printer to automatically switch between the serial and parallel port and between the Ethernet adapter and the serial port when NIC is installed.

Centronics Parallel Interface
The Centronics interface enables the printer to operate with controllers designed for buffered Centronics printers. The length of the data cable from the host computer to the printer must not exceed 15 feet (5 meters).
Table 18. Centronics Interface Connector Pin Assignments
Input Signals Output Signals Miscellaneous
Signal Pin Signal Pin Signal Pin
2 20 ACKNOWLEDGE
10 28 CHASSIS GROUND 17
DATA LINE 2
3 21 ONLINE
13 28 GROUND 30
DATA LINE 3
4 22 FAULT
32 29 Spares 14
5 23 PAPER EMPTY
12 28 No Connection 34, 35, 36
6 24 BUSY
11 29 +5 Volts 18
DATA LINE 7
DATA LINE 8
DATA STROBE
PAPER INSTRUCTION
PRIME

The Centronics interface signals between the host computer and the printer are defined as follows:
Data Lines 1 through 8. Provide eight standard or inverted levels from the host that specify a character or function code. Data Line 8 allows access to the extended ASCII character set. You may enable or disable this line via the Data Bit 8 parameter on the Centronics submenu.
Data Strobe. Carries a low true, 100 ns min. pulse from the host that clocks data into the printer.
Paper Instruction (PI). Carries a VFU control signal from the host with the same timing as the data lines.
Acknowledge. A low true pulse from the printer indicating the character or function code has been received and the printer is ready for the next data transfer.
Online. A high true level from the printer to indicate the printer is ready for data transfer and the ON LINE key on the operator panel has been activated. When the printer is in online mode, it may accept data from the host.
Paper Empty (PE). A high true level from the printer to indicate the printer is in a fault condition.
Busy. A high true level from the printer to indicate the printer cannot receive data.
Your printer is configured at the factory to match the interface you specified. By using the operator panel, you may verify and change several interface parameters in order to meet specific application requirements.
Some application programs require a unique configuration. If the printer is not working properly in the configuration you have selected, contact an authorized Printronix representative.
Centronics Interface Signals

Bi-Tronics Parallel Interface
The Bi-Tronics interface supports three operating modes, which are determined by negotiation between the printer and the host.
This mode provides compatibility with Centronics-like host I/O. Data is transferred from the host to the printer in 8-bit bytes over the data lines.
Compatibility mode can be combined with nibble and byte modes to provide bidirectional communication.
Eight bits equals one byte. When a byte of data is sent to the printer, the eight bits are sent over eight data lines.
Some devices cannot send data over their eight data lines. To bypass this, the Bi-Tronics interface permits data to be sent as half a byte over four status lines. (Half a byte equals one nibble.) Two sequential four-bit nibbles are sent over the lines.
Data is transferred from printer to host in four-bit nibbles over the status lines, and the host controls the transmission.
The printer and host send data to each other along eight data lines (one bit per line).
If bidirectional communication is supported by the printer and the host, the host will take control of the data transfer.

The negotiation phase determines which operating mode will be used. At this time, the host and the printer will sense what devices are attached, the supported signals available, and which mode to use. The selected mode, in turn, defines the pins on the Bi-Tronics interface connector.
There are 36 pins on the parallel interface. Each one sends a different signal. Pin 1, for example, can send a Strobe signal or a HostClk signal, depending on the mode selected. Table 19 shows the different definitions.
Bi-Tronics interface signals between the host and the printer are defined below.
Host Clock / nWrite. Driven by the host. Data is transferred from host to printer. When the printer sends data, two types are available. In Nibble mode, the signal is set high. In Byte mode, the signal is set low.
Data 1 through Data 8. These pins are host-driven in Compatibility mode and bidirectional in Byte mode. They are not used in Nibble mode. Data 1 is the least significant bit; Data 8 is the most significant bit.
Printer Clock / Peripheral Clock / Interrupt. Driven by the printer. A signal from the printer indicating the character or function code has been received and the printer is ready for the next data transfer.
Printer Busy / Peripheral Acknowledge / nWait. Driven by the printer. Indicates the printer cannot receive data. (Data bits 4 and 8 in Nibble Mode.)
Acknowledge Data Request / nAcknowledge Reverse. Driven by the printer. Indicates the printer is in a fault condition. (Data bits 3 and 7 in Nibble mode.)
Xflag. Driven by the printer. A high true level indicating the printer is ready for data transfer and the printer is online. (Data bits 2 and 6 in Nibble mode.)
Host Busy / Host Acknowledge / NDStrobe. Driven by the host. Activates auto-line feed mode.
Peripheral Logic High. Driven by the printer. When set high, the printer indicates all of its signals are in a valid state. When set low, the printer indicates its power is off or its signals are in an invalid state.
nReverse Request. Driven by the host. Resets the interface and forces a return to Compatibility mode idle phase.
nData Available / nPeripheral Request. Driven by the printer. Indicates the printer has encountered an error. (Data bits 1 and 5 in Nibble mode.)
1284 Active / nAStrobe. Driven by the host. A peripheral device is selected.
Host Logic High. Driven by the host. When set to high, the host indicates all of its signals are in a valid state. When set to low, the host indicates its power is off or its signals are in an invalid state.
nInit. Resets init interface from the host.
The Negotiation Phase

Table 19. Bi-Tronics Signals
Pin Source of Data
1 Host nStrobe HostClk Host/Clk
2 Host/Printer Data 1 (LSB)
3 Host/Printer Data 2
4 Host/Printer Data 3
5 Host/Printer Data 4
6 Host/Printer Data 5
7 Host/Printer Data 6
8 Host/Printer Data 7
9 Host/Printer Data 8 (MSB)
10 Printer nAck PtrClk PtrClk
11 Printer Busy PtrBusy PtrBusy
12 Printer PError AckDataReq AckDataReq
13 Printer Select Xflag Xflag
14 Host nAutoFd Host Busy HostAck
18 Printer Peripheral Logic High
19 Signal Ground (nStrobe)
20 Signal Ground (Data 1)
21 Signal Ground (Data 2)
22 Signal Ground (Data 3)
23 Signal Ground (Data 4)

Table 19. Bi-Tronics Signals (continued)
Pin Source of Data
24 Signal Ground (Data 5)
25 Signal Ground (Data 6)
26 Signal Ground (Data 7)
27 Signal Ground (Data 8)
28 Signal Ground (PError, Select, nAck)
29 Signal Ground (Busy, nFault)
30 Signal Ground (nAutoFd, nSelectIn, nInit)
32 Printer NFault nDataAvail aDataAvail
36 Host nSelectIn 1284 Active 1284 Active
The RS-232 and RS-422 serial interfaces enable the printer to operate with bit serial devices that are compatible with an RS-232 controller. The input serial data transfer rate (in baud) is selectable from the printer operator panel. Baud rates of 600, 1200, 2400, 4800, 9600, 19,200, and 38,400 are available for RS-232 and RS-422.
The input format consists of a single start bit, 7 or 8 data bits, and one or two stop bits. The number of data bits is determined by printer configuration. The data bits are interpreted with the least significant bit first. Parity checking is determined by printer configuration options selected from the operator panel.

The printer interface uses a first-in/first-out buffer. The asynchronous interface accepts data as it is provided by the host. The length of the data cable from the host computer to the printer must not exceed 50 feet (15 meters) for RS-232 or 4000 feet (1220 meters) for RS-422. (A copper conductor, twisted-pair telephone cable with a shunt capacitance of 16 pF/ foot [52.5 pF/meter] terminated in a 100 ohm resistive load must be used for the RS-422.)
Table 20. RS-232 Serial Interface Connector Pin Assignments
Input Signals Output Signals Miscellaneous
Signal Pin Signal Pin Signal Pin
Receive Data (RD) 3 Transmit Data (TD) 2 Chassis Ground 1
Clear To Send (CTS) 5 Request To Send (RTS) 4 Signal Ground 7
Data Set Ready (DSR) 6 Data Terminal Ready (DTR) 20
Data Carrier Detect (DCD) 8
Table 21. RS-422 Serial Interface Connector Pin Assignments
Input Signals Output Signals Miscellaneous
Signal Pin Signal Pin Signal Pin
- Receive Data (-RD) 15 - Transmit Data (-TD) 19 Chassis Ground 1
+ Receive Data (+RD) 17 + Transmit Data (+TD) 25 Signal Ground 7
The RS-232/RS-422 connector mounted on the printer is a 25-pin DB-25S type. The mating connector is a DB-25P. RS-232 and RS-422 compatible serial interface signals are defined as follows:
Transmitted Data (TD). Serial data stream from the printer for transmitting status and control information to the host. Subject to protocol selection.
Received Data (RD). Serial data stream to the printer.
Request To Send (RTS). Control signal from the printer. Subject to configuration.
Clear To Send (CTS). Status signal to the printer indicating the host is ready to receive data/status signals from the printer.
Data Set Ready (DSR). Status signal to the printer indicating the host is in a ready condition.

RS-232 And RS-422 Serial Interface Protocol
Data Carrier Detect (DCD). Status signal to the printer. The ON condition is required for the printer to receive data.
Data Terminal Ready (DTR). Control signal from the printer. Subject to configuration.
+RD, -RD. Serial data stream differentially received by printer.
+TD, -TD. Differentially driven serial data stream for transmitting status and control information to the host. Subject to protocol selection.
X-ON/X-OFF. The printer transmits an X-ON character (hex 11) when entering the Online mode or when the buffer is almost empty. The printer transmits an X-OFF character (hex 13) when entering the Offline mode or when the buffer is almost full.
Parity Error Handling. Parity error checking is a configuration option selected from the operator panel.
With odd or even parity checking selected, a character with a parity error is replaced with a question mark (?) character.
When parity checking is not selected (“NONE” on the operator panel), parity errors are ignored and the characters are printed as received.
Framing Error Handling. Framing error checking is always in effect for the serial interface.
When a framing error occurs, an exclamation point (!) is printed. If 20 successive errors are received, a line feed is added to force printing to occur.
Overrun Error Handling. Overrun error checking is always in effect for the serial interface.
When a data overrun error occurs, an asterisk (*) is printed. If 20 successive errors are received, a line feed is added to force printing to occur.

RS-232 And RS-422 Serial Interface Configuration
By using the control panel, you can verify and change several interface parameters in order to meet specific application requirements.
Refer to “Serial Submenu” on page 119 for RS-232 and RS-422 parameter descriptions and information on selecting values for the following parameters:
Some application programs require a unique configuration. If the printer is not working properly with the configuration you selected, contact an authorized Printronix representative.

Routine Service
Periodic cleaning ensures efficient operation and clear print quality, and it is the only maintenance your printer requires. If the printer is located in a dusty area or is used for heavy duty printing, clean it more often.
If print quality does not improve even after cleaning, contact your authorized Printronix representative.
Vor dem Säubern des Druckers ist die Netzverbindung zu unterbrechen.
Débranchez l’alimentation avant de nettoyer l’imprimante.
Desconecte la fuente de energía antes de limpiar la impresora.
Staccare la fonte di energia prima della pulitura della stampante.
Clean with a soft, lint-free cloth and mild detergent soap. (Dishwashing liquid works well.) Do not use abrasive powders or chemical solvents. Clean the windows with plain water or mild window cleaner. Always apply the cleaning solution to the cloth; never pour cleaning solution directly onto the printer.
Over time, particles of paper and ink accumulate inside impact printers. This is normal. Paper dust and ink build-up must be removed periodically to avoid degraded print quality. Most paper dust accumulates around the ends of the platen and ribbon path.
To clean the interior of the printer, perform the following steps and refer to Figure 22 for cabinet models.



Figure 22. Cleaning the Print Mechanism (Cabinet Models)
Interior Cleaning · Vertical Position Knob · Forms Thickness Lever


This section is designed to help you recover from any problems which may arise with normal printer operation.
The printer self-tests are used to check the print quality and operation of your printer. Your authorized Printronix representative will typically run these tests. For a description of each test, see page 129.
To activate a test, select it and press the ENTER key. To stop the test, press ENTER again.
An example procedure for running the self-test “All E’s,” which determines whether print quality is acceptable, is described in Table 22.
Table 22. Sample Print Test (All E’s)


Table 22. Sample Print Test (All E’s) (continued)

Printer Self-Tests

Printing A Hex Dump

Figure 23. Hex Dump Sample
A hex code printout (or hex dump) is a translation of all host interface data to its hexadecimal or symbolic equivalent. A hex dump lists all ASCII character data received from the host computer with their corresponding two-digit hexadecimal codes. Hex dumps are used to troubleshoot printer data reception problems.
Printable characters print as the assigned symbol; nonprintable characters are indicated by a period (.).
See Appendix C for hex-to-ASCII conversion. Table 23 shows the procedure for printing a hex dump.

Printing A Hex Dump
Table 23. Printing a Hex Dump


Fault Messages
If a fault condition occurs in the printer, the status indicator on the control panel flashes on and off, and the message display indicates the specific fault. Fault messages are summarized in Table 24.
For operator correctable faults, follow the suggested corrective action in the fault message description. After correcting the displayed fault, press the CLEAR key to clear the error message and status indicator, and resume printing. If the fault message reappears, contact your authorized Printronix representative.
For faults that require field service, do two things to try to clear the fault before calling your authorized Printronix representative:
Table 24 explains the fault messages and offers solutions where possible.

Table 24. LCD Message Troubleshooting Table
Displayed Message Explanation Action Required
8.5V PWR FAIL* Internal power failure. Contact your authorized Printronix representative.1
15V PWR FAIL* Controller voltage failure. Contact your authorized Printronix representative.1
23.5V PWR FAIL* Controller voltage failure. Contact your authorized Printronix representative.1
48V PWR FAIL* Internal power failure. Contact your authorized Printronix representative.1
A TO D OVERUN* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
ACCESS NULL PTR* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
BUFFER OVERRUN Host sends data after the printer buffer is full. (Serial interface.)
Check your serial host interface parameter settings; if necessary, adjust them so they match the settings of the attached host.
CLEAR PAPER JAM No paper motion. Clear jam and reload paper. (See Quick Reference Guide.) If this message recurs, contact your authorized Printronix representative.1
The program successfully loaded into printer RAM and the checksum matched. The old program is now being deleted from flash memory.
CLOSE PLATEN The forms thickness lever is open. Close the forms thickness lever.
COIL HOT* One or more hammer coils are overheating.
Contact your authorized Printronix representative.1
CTL VOLT FAIL* Controller voltage failure. Contact your authorized Printronix representative.1
The printer passed its memory and hardware initialization tests.
DRVR CIR BAD* Hammer coil count test failed. Contact your authorized Printronix representative.1
Fault Messages · None · None

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
Printer cannot find the data controller program or the validation checksum is corrupt.
Download the program again. If the message occurs again, call your authorized Printronix representative.1
The printer found a defective memory location.
Call your authorized Printronix representative.1
Printer cannot find the engine controller program or the validation checksum is corrupt.
Download the program again. If the message occurs again, call your authorized Printronix representative.1
Hardware fault in the engine controller.
Call your authorized Printronix representative.1
The printer encountered an error trying to program flash memory.
Download the program again. If the message occurs again, call your authorized Printronix representative.1
The printer could not find any flash memory.
Call your authorized Printronix representative.1
The printer could not find any DRAM.
Call your authorized Printronix representative.1
The security PAL is not present or the non-volatile memory has failed.
Call your authorized Printronix representative.1
The printer requires more DRAM memory in order to run the downloaded program.
Add DRAM. Call your authorized Printronix representative.1
The printer requires more flash memory in order to run the downloaded program.
Add flash memory. Call your authorized Printronix representative.1
The printer is not compatible with the downloaded program.
Use the correct emulation software option(s) for this model.
The printer does not see a program in flash memory.
There is no program in printer memory. Download program again.
The security PAL is not present or has failed.
Call your authorized Printronix representative.1
Hardware failure in DRAM or CMX controller circuitry.
Call your authorized Printronix representative.1

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
Hardware or software fault in flash memory.
Download the program again. If the message occurs again, call your authorized Printronix representative.1
The printer received the complete program but the checksum did not match. The data was corrupted during download.
Download the program again. If the message occurs again, call your authorized Printronix representative.1
NIC is processing the boot procedure.
NIC has established communication.
EXHAUST FAN FLT Sensors cannot detect current in fan circuit.
Power off the printer and remove the paper path. Check that the fan cable connector is connected. Check for obstruction of vents and fan airway, and remove any obstructions. Check for items beneath the printer blocking cabinet vents. Power back on the printer. If this message recurs, contact your authorized Printronix representative.1
FIRMWARE ERROR* Application software tried to perform an illegal printer function or damaged memory detected on board.
Contact your authorized Printronix representative.1
FRAMING ERROR Serial framing error. (Serial interface.)
Check your serial host interface parameter settings; if necessary, adjust them so that they match the settings of the attached host.
HAM. COIL OPEN* Electrical malfunction of one or more hammer coils.
Contact your authorized Printronix representative.1
HAMMER COIL BAD X, X, X,...
Coil # failed current test at power- up.
Record message, clear to continue printing, and contact your authorized Printronix representative.
HB NOT INSTALLD* Self-test does not detect hammer coils.
Contact your authorized Printronix representative.1
Fault Messages · None · None

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
HMR BANK FAN FLT Sensors cannot detect current in fan circuit.
Power off printer and remove paper path. Check that fan cable is connected. Check for obstruction of vents and fan airway; remove any obstructions. Check for items beneath the printer blocking cabinet vents. Power back on the printer. If this message recurs, contact your authorized Printronix representative.1
ILL EXT BUS ACC* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
ILL INST ACCSS* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
ILLGL OPR ACCSS* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
INTAKE FAN FAULT Sensors cannot detect current in fan circuit.
See description for HMR BANK FAN FLT.
LO DRV. SHORT * Circuit(s) on the hammer bank or in the hammer bank power cable shorted to ground.
Contact your authorized Printronix representative.1
LOAD PAPER Printer is out of paper. Load paper. (See Quick Reference Guide.)
The new program is loading into printer RAM. XX indicates how much of the program has loaded.
The printer has deleted the previous program from flash memory and is loading the new program into flash memory.
PAP BAD TABLE* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP BSY TOO LNG* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP FIFO OVERFL* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP FIFO UNDRFL* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
None · None

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
PAP ILLGL ST* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP INCMPL ENER* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP INVLD CMD* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP INVLD PARM* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP NOT SCHED* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP NT AT SPEED* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PAP UNEXP INT* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PARITY ERROR Parity error (serial interface)
Check your serial host interface parameter settings; if necessary, adjust them so they match the settings of the attached host.
PLAT INV CMD* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PLAT INV PARM* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PLAT INV STATE* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
POWER SAVER MODE Status message: printer is in low- energy idle state; all fans and higher voltages are off; only +5Vdc logic circuits are active.
POWER SUPPLY HOT* Circuits are overheating on the power supply board.
Contact your authorized Printronix representative.1
PRINTER HOT* Controller board sensors report high temperatures on the board.
Contact your authorized Printronix representative.1
PROTECTED INSTR* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
PWR SUPP VOLT * Power supply failed. Replace power supply board.
Fault Messages · None

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
The printer finished loading the program into flash memory and is automatically resetting itself.
Normal download initialization message.
RIB INVLD CMD* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
RIB INVLD STATE* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
RIBBON DRIVE* CMX controller does not detect ribbon drive motor.
Contact your authorized Printronix representative.1
RibbonMinder software has determined that the ribbon is out of ink.
Install a new ribbon and set ribbon life to 100%.
Security code of PAL on controller board does not match code of firmware on the controller board.
Contact your authorized Printronix representative.1
The security PAL is missing or has failed.
Contact your authorized Printronix representative.1
The printer is loading the engine controller program into the engine controller.
SHUTL INV CMD* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
SHUTL INV PARM* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
SHUTTLE JAM No shuttle movement or shuttle is moving at the wrong speed.
Check for obstruction to shuttle, a twisted ribbon, or forms thickness lever closed too tightly. If fault source is not apparent, contact your authorized Printronix representative.
Application software tried to perform illegal printer function, or damaged logic circuits were found on controller board.
Contact your authorized Printronix representative.1
STACK OVERFLOW* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
None · None · None

Table 24. LCD Message Troubleshooting Table (continued)
Displayed Message Explanation Action Required
STACK UNDERFLOW* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
STACKER FAULT Failed motor circuit. Contact your authorized Printronix representative.1
STACKER FULL Reached full capacity. Remove paper stack.
STACKER JAM Jammed paper, or foreign object, in unit's travel path.
Remove paper or foreign object.
EC software update in progress. Download the program again.
TCB CORRUPTED* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
UNDEF INTERRUPT* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
UNDFNED OPCODE* Fatal firmware error on controller board.
Contact your authorized Printronix representative.1
UP DRV. SHORT * Hammer driver circuits on the boards shorted to ground.
Contact your authorized Printronix representative.1
This status message appears when the printer is first powered on if the optional NIC is installed.
1 Before contacting an authorized Printronix representative, power off the printer, wait 15 seconds, then power it back on and rerun your print job. If the message reappears, press CLEAR. If the fault message still displays, then contact your authorized Printronix representative.
Fault Messages · None


Ribbon Specifications
Use only these Hewlett-Packard ribbons in LP Series and LineJet printers:
Quanity Ribbon Type Yield Compatibility
High Yield Gold Series Ribbons for Increased Productivity
172293-001 N/A 6 pack Text/Barcode/OCR 30 Million Characters 3400 Shipping Labels All Printronix line matrix printers All HP LineJet and LP Series printers
175006-001 N/A 6 pack Text/Barcode/OCR 50 million characters 4800 shipping labels All Printronix line matrix printers
All HP LineJet and LP Series printers
179006-001 N/A 6 pack Text/Barcode/OCR 90 million characters 7400 shipping labels All Printronix cabinet model line matrix printers
HP LineJet 500Q, 1000Q, 1500LQ
HP LPQ500k, LPQ1000, LPQ1500, LPQ475
HP Product Reference · Printronix Part Number

Quanity Ribbon Type Yield Compatibility
107675-001 C3207A 6 pack Text 30 million characters All Printronix line matrix printers
All HP LineJet and LP Series printers
107675-007 C3208A 6 pack Text 50 million characters All Printronix cabinet model line matrix printers
HP LineJet 500Q, 1000Q, 1500Q
107675-005 C3209A 6 pack Barcode/OCR 27 million characters 2800 shipping labels All Printronix line matrix printers
All HP LineJet and LP Series printers
107675-008 C3210A 6 pack Barcode/OCR 45 million characters 4667 shipping labels All Printronix cabinet model line matrix printers
HP LineJet 500Q, 1000Q, 1500Q
140768-001 C3212A 6 pack Non-inked, security 30 million characters All Printronix line matrix printers
All HP LineJet and LP Series printers
HP Product Reference · Printronix Part Number · Standard Ribbons

For additional information or to locate the Genuine PRINTRONIX Supplies distributor in your area, e-mail p5000lj@printronix.com or contact:

Printer Dimensions
Cabinet Model:
Cabinet Model with Power Stacker Option
Width 27 inches (68.6 cm)
Pedestal Model:
Operating:
41° to 104° F (5° to 40° C) up to 5000 feet (1524 meters)
41° to 90° F (5° to 32° C) up to 8000 feet (2438 meters)
Storage:
- 40° to 158° F (- 40° to 70° C)

P5000LJ printers comply with the requirements of the ENERGY STAR® Office Equipment Program of the U.S. Environmental Protection Agency. When in the reduced power state, the printer displays “Power Saver Mode,” and is activated at the control panel.
Printing, Typical1 2.15A 2.43A 3.28A 4.37A 3.72A
Printing, Maximum2 3.60A 3.05A 4.39A 6.06A 5.19A
Non-Printing3 0.90A 1.17A 1.19A 1.16A 1.10A
Printing, Typical1 190W 191W 271W 364W 310W
Printing, Maximum2 320W 244W 380W 514W 440W
Non-Printing3 90W 84W 86W 84W 80W
Printing, Typical1 648 BTU/hr 652 BTU/hr 925 BTU/hr 1342 BTU/hr 1058BTU/hr
Printing, Maximum2 1092 BTU/hr 833 BTU/hr 1297 BTU/hr 1754 BTU/hr 1502BTU/hr
Non-Printing3 307 BTU/hr 287 BTU/hr 294 BTU/hr 287 BTU/hr 273BTU/hr
1 Printing, Typical = 120 VAC, 50/60 Hz, Shift Recycle (ASCII Swirl), High Speed Mode
2 Printing, Maximum = 120 VAC, 50/60 Hz, All Black, High Speed Mode
3 Non-Printing = 120 VAC, 50/60 Hz, Standby Mode
Current · Power · Heat

Material Safety Data Sheets

Federal Communications Commission (FCC) Statement: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provided reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Printronix is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by any unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Canadian Department of Communications Compliance Statement: This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformite aux normes du ministere des Communcations du Canada: Cet appareil numerique de la classe A est conform á norme NMB- 003 du Canada.
European Community (EC) Conformity Statement: This product is in conformity with the protection requirements of EC Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Printronix cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-Printronix option cards.
Dieses Gerät ist berechtigt in Übereinstimmung mit dem deutschen das EG- Konformitätszelchen - CE - zu führen.
Der Außteller der Konformitätserklärung ist die Printronix (1)
Informationen in Hinsicht EMVG Paragraph 3 Abs. (2) 2:
Das Gerät erfüllt die Schutzanforderungen nach EN 50082-1 und EN 55022 Klasse A.




Introduction
P5000LJ Series printers use dot matrix line printing technology, which permits a high degree of printing flexibility. Dot matrix technology enables the user to print graphic images, line drawn characters, special characters, and multiple alphabets.
The first section of this appendix lists general specifications for continuous form paper. (Specific brands or types of paper are not recommended.) Adherence to these specifications will ensure the best print quality and reliable operation.
The second section goes into more detail, providing definitions, guidelines, and a checklist to use for designing forms that will run smoothly through the print station of the P5000LJ Series printer.
This section describes the minimum paper specifications that must be met to ensure the best printer performance.
Always test paper and forms before buying large quantities. Make all measurements at 20° to 26° Celsius (68° to 78° Fahrenheit) and 45% to 55% relative humidity. P500LJ printers perform well with forms that meet the specifications listed in Table 25 and Table 26 below.

Table 25. Paper Sizes
Maximum form width 17.0 inches (43.18 cm) edge to edge
Minimum form width 3.0 inches (7.62 cm) edge to edge
Maximum Printing Width 13.6 inches (34.54 cm)
Maximum Right Margin 1 to 13.6 inches (2.54 to 34.54 cm)
Maximum Left Margin 0 to 13.5 inches (0 to 34.29 cm)
Maximum Form Length 16 inches (40.64 cm)
Minimum Form Length 2 inches (5.08 cm)
Table 26. Paper Weights
Standard 15 to 100 pound (57 to 380 gm/meter2)
Best Print Quality 18 to 60 pound (68 to 227 gm/meter2)
Carbon Paper 12 pounds (46 gm/meter2) up to 6 total pages
Carbons 8 pounds (30 gm/meter2) up to 6 total pages
Pack Thickness Maximum 0.025 inch (0.635 mm) total
Carbonless Up to 4-part forms
Test the paper first if you plan to use it in environments with humidity of less than 20% or greater than 80%. Also test paper that you plan to use at high humidity to ensure satisfactory feeding and handling, and test paper to be used at low humidity to determine if static buildup must be eliminated for proper paper stacking.
Single-Part Forms · Multipart Forms

The terms below describe continuous form paper.
Chaff Residual bits of paper not completely removed after the punch process that creates tractor pin holes, major and minor perforations, etc.
Cut Point The area along a perforation where a cut has been made that extends through the entire form.
Cut-to-Tie Ratio The ratio of cut points to tie points occurring along a perforation.
Evenness The amount of variation between the thickest and thinnest points measured across the print area (i.e., between the side perforations).
Form Thickness Thickness measured at the thickest point of the entire form. This includes glue lines, compressed staples, perforations, etc., and is not limited to the printed region of the form.
Margin The region outside the print area of the form. The margin is typically bounded by the outermost vertical perforations (i.e., where the tractor holes are located) and the edge of the form.
Print Area The region where printing occurs, and which is always between the side perforations.
Print Station The area in the printer where the actual impacts of printing occur.
Staple A punch-cut fastening stitch located along the vertical edge and within the side perforation region of a multipart form. (Note that this is not a metal staple.)
Tenting The measured thickness between the print area of the form and the peak thickness of a major perforation. Tenting is typically caused by overly stiff perforations or incorrect registration of the inner parts of multipart forms.
Tie Point The area along a perforation between the cut points (see above).
Terms And Definitions


The figures below illustrate the terms used in this appendix.

Figure 24. Basic Forms Terminology
Side View of Form
Printed Side of Form
Figure 25. Inward and Outward Perforations

Figure 26. Cut Points and Tie Points
Side Perforation · Outward Perforation · Inward Perforation

Before they are used, forms should be stored for at least 24 hours— preferably 48 hours—in the environment in which they will be used. This stabilizes the moisture content of the paper, resulting in better feeding and stacking. Forms should never be stored in environments that result in damage such as delamination of glues, creasing, folding, etc.
For all forms, the width range is from 3 to 17 inches, and the length range is from 2 to 12 inches.
Use 15 to 100 pound (6.80 to 45.36 kg) stock. Light weight and recycled forms must be strong enough to assure that tractor holes and perforations do not tear or detach during form feed, skipping, and ejecting operations.
Forms must be no thicker than 0.025 inches (0.0635 cm). This figure is for the thickest point of the form—including glue lines, staples, perforations, etc.— and is not restricted to just the print area.
The evenness of forms must not exceed 0.003 inches (0.00762 cm) across the print area (between the side perforations).
Tenting caused by buildup of perforation thickness must be minimized. A perforation thickness measured at the major perforation that exceeds 1.25 times the forms thickness measured in the print area will result in an unpredictable and unreliable form. The perforation thickness must never exceed the maximum forms thickness of 0.025 inches (0.0635 cm).
The printer uses tractors with 6-pin engagement. Detailed engagement specifications are given in ISO-2784, but are summarized in the table below.
Environmental Considerations

Hole centerline (CL) to edge of form 0.236 ± 0.028 6.0 ± 0.10
Hole Diameter (Serrations or any occlusion due to incorrect registration of multipart forms cannot exceed this dimension.)
0.156 ± 0.004 4.0 ± 0.10
Distance between centers of two consecutive holes
0.500 ± 0.002 12.7 ± 0.05
Maximum deviation of holes from their centerline
0.004 0.10
Maximum deviation of lefthand hole to adjacent righthand hole (CL to CL)
0.006 0.15
Maximum parallel deviation of lefthand hole CL to righthand hole CL
0.006 0.15
Any method of attachment (staples, crimps, gluing, etc.) must be designed in a way that does not permit air to be trapped between copies of a form. Hard or wire brads and staples must not be used.
Any attachment must not coincide with the major perforation or any horizontal perforation.
Gluing must be controlled and uniform, since it is a major contributor to the maximum form thickness. A form that meets the maximum forms thickness requirement in the print area but which exceeds the maximum thickness at a glue line is considered an unreliable and unpredictable form.
Staples must be used only in the margin area of the form and must not be in line with the path of the tractor holes. Ideally, staples are placed in the margins so that they coincide with areas of the form where printing does not occur.
The figure below shows acceptable and unacceptable ways of fabricating staples.
Specification Inches Millimeters

Direction of Forms Movement
Tie Point Cut Point
A common cut-to-tie ratio for bond forms is 4:1 (that is, 80% cut to 20% ties). This value is dictated chiefly by the application program under which the form runs. Lower cut-to-tie ratios will yield better form handling, but stacking may suffer due to increased stiffness of the perforations. Some level of experimentation is required to determine the best cut-to-tie ratio. But remember that a cut-to-tie ratio that causes a thickness buildup of greater than 0.025 inch (0.635 mm) or that creates an evenness variation of greater than 0.003 inch (0.0762 mm) will result in an unreliable and unpredictable form.
Whenever a horizontal perforation intersects with a vertical perforation, the point of intersection must be a tie point. Cut points at such intersections make the form unacceptable.
Tractors holes should be clear of chaff. As much as possible, there should not be loose chaff in the box in which the paper is packed.

Form Design Checklist
Use this checklist to help you remember key areas of consideration when designing and ordering forms and paper stocks.
Before they are used, forms are given at least 24 hours of condensing time in the environment in which they will be used.
Forms are not stored in environments that result in damage such as delamination of glue lines, creasing, folding, etc.
Form Type (Check One)
1 Part 2 Part 3 Part 4 Part 5 Part 6 Part
< Carbonless Range >
< Carbon Range >
Recycled Paper? Yes No If yes, assure adequate form strength to prevent tractor holes and perforations from tearing or detaching during form feeds and page ejects.
Security Form? Yes No If yes, the last page of the form should have a minimum 50% reflectance, and, if possible, the stippled page faces inward to the form.
Form weight = (Minimum = 15 lb. / 6.8 kg ; Maximum = 100 lb / 45.36 kg)
Form thickness = (0.025 inches / 0.0635 cm maximum measured at the thickest point of the form, which includes perforations, compressed staples, glue lines, etc.)

The evenness of the form = (Not to exceed 0.003 in. / 0.00762 cm)
Tenting due to buildup of perforation thickness must be minimized. A perforation thickness measured at the major perforation that exceeds 1.25 times the forms thickness measured in the print area will result in an unreliable and unpredictable form. Perforation thickness must not exceed the maximum form thickness of 0.025 in. / 0.0635 cm.
The holes which engage the tractor pins must conform to the following specifications:
Hole centerline (CL) to edge of form 0.236 ± 0.028 6.0 ± 0.1
Hole Diameter (Serrations or any occlusion due to incorrect registration of multipart forms cannot exceed this dimension.)
0.156 ± 0.004 4.0 ± 0.1
Distance between centers of two consecutive holes
0.500 ± 0.002 12.7 ± 0.05
Maximum deviation of holes from their centerline
0.004 0.1
Maximum deviation of lefthand hole to adjacent righthand hole (CL to CL)
0.006 0.15
Maximum parallel deviation of lefthand hole CL to righthand hole CL
0.006 0.15
Must not allow air entrapment between copies of the form
Must not use hard brads or staples
Must not coincide with major perforation or any horizontal perforation
Gluing lines must not result in a form that exceeds 0.025 in. / 0.0635 cm thickness
Staples must be used only in margin area of form
Staple cuts must not be in the direction of form movement through the tractors
Staples must not occur in-line with the path of the tractor holes
Staples should be placed in the margins so that they coincide with areas of the form where printing will not occur
Chaff Content · Specification Inches Millimeters

Cut-To-Tie Ratio
: (Typical ratio is 4:1, or 80% cut to 20% tie)
Thickness Buildup = in. / cm
Horizontal-vertical perforations are tie points. Cut points at such intersections are unacceptable.
Tractor holes are clear of chaff.
There is no loose chaff in the box the paper is packed in.
Because it is impossible to test all possible forms available for use in the printer, Printronix recommends that paper conform to the specifications outlined in this appendix for the best printer performance.
But the guidelines in this appendix are not a substitute for actual testing. Always test forms—including special single-part paper, multipart forms, forms with glue strips, carbonless forms, card stock, and labels—for satisfactory feeding, registration, and print quality prior to purchase. For best results in selecting standard or specialty forms, consult a forms vendor who can ensure conformance to the guidelines in this appendix and who can recommend cost- effective purchases.
The performance of the printer depends to a large degree on the condition of the paper used; therefore, the following principles for packaging, handling, and storage are recommended.
To avoid damage during handling, use top and bottom fillers in continuous form cartons to hold the paper stack firmly in place. Proper packaging ensures that the paper remains flat and is not damaged along the edges.

Do not store cartons directly on the floor, and do not stack them more than six high. Set each carton upright and squarely on the one underneath. Do not place anything else on the stack of paper, because this can damage the paper.
Protect paper from temperature and humidity extremes. Store paper in the same environment as the printer for 24 to 48 hours before using the paper. This allows the moisture content of the paper to stabilize.
LP Series and LineJet printers are used at temperatures from 5° to 40° C (41° to 104° F) up to 1524 meters (5000 feet), from 5° to 32° C (41° to 90° F) up to 2438 meters (8000 feet), with a non-condensing relative humidity of 10% to 90%. For best results, however, store the printer paper at 18° to 24° C (65° to 75° F), with a relative humidity of 40% to 50%.
If the printer is in an environment subject to extremes of temperature or humidity, store the printer paper in a better environment and move it to the printer as needed.
Storage And Handling


B7 B6 B5
KEY
B4 B2 B3 B1
33 27 1B
OCTAL DECIMAL HEX
ESC
1 0 1 1
B7 0 1 B6 0 B5 0 0 1 1 0 1 1 0 0 0 1 1 0 1 1
0 1 2 3 4 5 6 7 BITS
ROW B4 B2 B3 B1
P
NUL
DLE
SP
0
DC1
A
Q
0 0 1 0
0 0 1 0
DC2
B
R
ETX
DC3
S
0 0 1 1
0 1 0 0
DC4
D
T
ENQ
NAK
E
U
0 1 0 1
0 1 1 0
SYN
F
0 1 1 1
ETB
G
W
BS
CAN
H
1 0 0 0
1 0 0 1
EM
Y
LF
12 10 A
SUB
32 26 1A
*
52 42 2A
:
J
112 74 4A
Z
132 90 5A
152 106 6A
172 122 7A
1 0 1 0
1 0 1 1
ESC
K
11 B
27 1B
43 2B
59 3B
75 4B
91 5B
107 6B
123 7B
FF
14 12 C
FS
34 28 1C
54 44 2C
74 60 3C
114 76 4C
134 92 5C
154 108 6C
174 124 7C
1 1 0 0
1 1 0 1
GS
M
13 D
29 1D
45 2D
61 3D
77 4D
93 5D
109 6D
125 7D
SO
16 14 E
RS
36 30 1E
56 46 2E
76 62 3E
N
116 78 4E
^
136 94 5E
156 110 6E
~
176 126 7E
1 1 1 0
37 31 1F
57 47 2F
77 63 3F
117 79 4F
137 95 5F
157 111 6F
177 127 7F
1
US
O
DEL


Implementing Remote Management Software (RMS)
A MIB is a Management Information Base that contains information a device makes available to SNMP. The MIB describes information about actual objects to be managed, controlled, and viewed. There are many different MIBs defined.

Components of the Printer MIB
The printer MIB gives the network manager access to most of the information that is normally accessible through the NIC command set for configuring the server with SNMP. Some objects identified by this MIB are not applicable to the NIC.
The Printer MIB contains the following types of information about network printers:
Descriptions. Printer configuration, location, and contact.
Status. Current operating status of printers.
Alerts. Reportable events from printers.
SNMP is the network protocol used to communicate between manager and agent. Managers request information, usually through automated polling at specified intervals, and agents respond. Though used primarily on TCP/IP networks, SNMP can be implemented on other protocols, for example, IPX.
SNMP is a standard by which a network manager can get statistics and configuration information from the NICs and other devices on the network. This is done through a Network Management Station (NMS), such as OpenView and NetView.

Monitoring With AIX NetView/6000
Many tools can be used to monitor printers with SNMP agents. One of these tools is NetView. There are also other MIB browsers, which are not described here.
The AIX NetView/6000 program can manage any IP-addressable device with an SNMP agent.
NetView/6000 can be used to set a network topology, monitor a network, diagnose problems, and measure network performance.
Through its MIB Browser, information about the resources affecting an event (such as an alarm) can be obtained.
Web JetAdmin (version 6.x) can monitor IP addressable devices containing the printer MIB.
To get SNMP.EXE to work correctly to browse MIB items, you may need to delete the following file: d:\mptn\etc\mib2.tbl
The default SNMP read-only community name is “public” and cannot be changed.
Change the SNMP R/W community name with the command: set user passwd snmp com_name save where com_name is the new SNMP R/W community name.
The default is no R/W community name.

Reference
To obtain the latest copy of these and other RFCs, FTP the files from one of the following two sources:




















Printronix, Inc. 14600 Myford Road Irvine, CA 92606-1005 Phone: 714 / 368-2300 Fax: 714 / 368-2600 Customer Solutions Center: 714 / 368-2686
Printronix Nederland BV P.O. Box 163, Nieuweweg 283 NL-6600 Ad Wijchen The Netherlands Phone: (31) 24 6489489 Fax: (31) 24 6489499
Printronix Schweiz GmbH 42 Changi South Street 1 Changi South Industrial Estate Singapore 486763 Phone: (65) 6542-0110 Fax: (65) 6543-0220
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.