EN
Powermate logo
Official user manual

Powermate PM0401854

12 pages·1.8 MB·Portable Generator·PDF·ENDEFRITNLJA
Powermate PM0401854
Table of Contents 9 sections PM0401854 Insert Additif Adición · ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO · www.colemanpowermate.com LFL 09/03 0062180 · MAJOR GENERATOR FEATURES · … ShowHide
Page 1 of the Powermate PM0401854 user manual — www.colemanpowermate.com LFL 09/03 0062180
Page 1 · click to enlarge
Page 1

PM0401854 Insert Additif Adición

Powermate PM0401854 — PM0401854 Insert Additif Adición diagram (page 1)
Fig. 1 · PM0401854 Insert Additif Adición

ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO

Powermate PM0401854 — ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO diagram (page 1)
Fig. 2

www.colemanpowermate.com LFL 09/03 0062180

Page 2 of the Powermate PM0401854 user manual — 2 English
Page 2 · click to enlarge
Page 2

MAJOR GENERATOR FEATURES

becomes more fully charged, the output current to the battery decreases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after a maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery. The charge level of the battery should be checked periodically.

* 3.5 HP Briggs & Stratton engine

* Receptacles on endbell

* 1 gallon plastic fuel tank

ENDBELL

Before charging a storage battery, check the electrolyte fluid level in all the cells. Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer's required level.

A . 120 V, 15 Ampere Duplex Receptacle

This duplex is split so that 15 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings.

B. Circuit Breaker The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

Use cables approved for battery charging. Connect a red clip to the positive terminal of the battery. Connect a black clip to the negative terminal of the battery. Connect the other end of the clip wire to the corresponding black(-) and red (+)binding posts on the generator panel. After the battery is fully charged, remove the battery charging cable from the generator and then disconnect from the battery posts.

C. Engine Switch

DC CIRCUIT BREAKER: The maximum current available from the battery charger circuit is 15 amps. An automatic DC circuit breaker has been provided to protect the circuit from overloads and assure that the battery gets recharged. If an overload occurs, the circuit breaker will trip. After it cools, it will automatically reset itself. The battery's maximum rate of charge will eventually reduce to less than 15 amps and then to zero as the battery approaches a 100 percent state of charge.

D. Battery Charger NOT RECOMMENDED FOR USE WITH GEL PACK, SEALED OR SMALL (MOTORCYCLE) BATTERIES.

These generators contain an additional circuit used for battery charging purposes. A two-prong DC receptacle is provided on the control panel. A battery charging cable equipped with a matching plug for this receptacle has been supplied with the unit.

The battery charger on this generator is referred to as an unregulated taper charger - the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery's state of charge. As the battery

2 English

* Battery charger · * Spark arrester · * Brushless generator

Page 3 of the Powermate PM0401854 user manual — 3 English
Page 3 · click to enlarge
Page 3

LIMITED WARRANTY (NOT VALID IN MEXICO) ENGINE MAINTENANCE SCHEDULE

Check engine oil Before each use Change engine oil After first 20 hours and then

every 50 hours of operation Clean air filter Every 50 hours of operation Clean spark plug Every 100 hours of operation Clean spark arrestor Every 50 hours of operation

This product is warranted by Coleman Powermate, Inc. to the original retail consumer against defects in material and workmanship for a period of one (1) year from the date of retail purchase and is not transferable. This one year warranty applies only to products used in consumer applications. If this generator is used in a commercial application, then the period of warranty coverage is limited to ninety (90) days from the date of purchase.

Oil Type. Use new good quality oil such as SC, SD, and SE grades. The oil to be used depends upon the temperature at which the engine is operated:

Summer: (temperatures of over 40 degrees F/10 degrees C) SAE 30 or SAE 10W-30, SAE 10W-40

Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty.

Winter(temperatures of below 40 degrees F/10 degrees C) SAE 20 or SAE 10W-30

WHAT IS COVERED: Replacement parts and labor.

SPARK ARRESTER MUFFLER

WHAT IS NOT COVERED: Transportation charges to Coleman Powermate, Inc. for defective products. Transportation charges to consumer for repaired products. Brushes, fuses, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure to perform normal maintenance. Power units or engines which are covered exclusively by the warranties of their manufacturer. Sales outside of the United States or Canada. Any other expense including consequential damages, incidental damages, or incidental expenses, including damage to property. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This engine is equipped with a U.S. Forest Service approved spark arrest muffler. It should periodically be cleaned to prevent the screen from becoming clogged, which could hamper engine performance.

To clean, remove the muffler shield. Remove the four screws and pull the plate with the screen attached. Clean off any particles with a brush and reinstall. Be sure gasket is in place.

Powermate PM0401854 — SPARK ARRESTER MUFFLER diagram (page 3)
Fig. 3

IMPLIED WARRANTIES: Any implied warranties, including the Implied Warranties of Merchantability and Fitness For A Particular Purpose, are limited in duration to one (1) year from the date of retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

HOW TO OBTAIN WARRANTY PERFORMANCE: Replacement parts and service are available from Coleman Powermate, Inc. Service Centers. Locate your nearest Service Center by calling TOLL FREE 1-800-445-1805. In the unlikely event a Service Center can not be located you may call Coleman Powermate, Inc. for a return authorization number. Any unit returned WITHOUT an authorization number will be refused.

To the extent any provision of this warranty is prohibited by federal, state, or municipal law, and cannot be preempted, it shall not be applicable. This warranty gives you specific rights, and you may also have other rights which vary from state to state.

3 English

Ask about the Powermate PM0401854

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Powermate PM0401854

Be the first to ask — other owners or our team will answer.

Original document

Powermate PM0401854 manual PDF

12 pages·1.8 MB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…