EN
Planet Technology logo
Official user manual

Planet Technology WSD-800

106 pages·2.9 MB·Switch·PDF·ENDEFRITNLJA
Planet Technology WSD-800
Table of Contents 93 sections 1. INTRODUCTION · 1.1 Packet Contents · 1.2 How to Use This Manual · 1.3 Product Feature · … ShowHide
1. INTRODUCTIONp.61.1 Packet Contentsp.61.2 How to Use This Manualp.61.3 Product Featurep.71.4 Product Specificationp.72. INSTALLATIONp.102.1 Product Descriptionp.102.1.1 Product Overviewp.102.1.2 Switch Front Panelp.102.1.3 LED Indicationsp.112.1.4 Switch Rear Panelp.122.2 Install the Switchp.132.2.1 Desktop Installationp.132.2.2 Rack Mountingp.142.2.3 Installing the SFP transceiverp.153. CONSOLE MANAGEMENTp.173.1 Connecting to the Switchp.173.2 Login in the Console Interfacep.173.3 Console Managementp.183.4 Telnet loginp.193.5 Commandsp.193.5.1 First level commandsp.193.5.2 Privileged Commandp.203.5.2.1 Clear commandp.203.5.2.2 Copy commandp.213.5.2.3 Disable commandp.213.5.2.4 Reboot commandp.223.5.2.5 Set commandp.223.5.2.6 Show commandp.244. WEB-BASED MANAGEMENTp.264.1 About Web-based Managementp.264.2 Preparing for Web Managementp.264.3 System Loginp.264.4 Systemp.274.4.1 IP Configurationp.274.4.2 SNMPp.284.4.2.1 Theoryp.284.2.2.2 SNMP Configurationp.294.4.3 Passwordp.324.4.4 CONSOLEp.324.4.5 System Upgradep.324.4.6 Saving Parametersp.334.4.7 Parameters Backup & Recoveryp.334.4.8 Load Defaultp.344.4.9 Rebootp.344.5 Port Managementp.354.5.1 Port Configurationp.354.5.2 Port Statisticsp.354.5.3 Port Band Restrictp.364.6 Redundancyp.364.6.1 Spanning Treep.364.6.2 Spanning Tree Configurationp.424.6.3 Link Aggregationp.454.7 Securityp.464.7.1 VLANp.464.7.1.1 Theoryp.464.7.1.2 VLAN Configurationp.504.7.2 MAC Address Bindp.554.7.3 MAC Address Filteringp.564.7.4 MAC Address Learningp.574.7.5 MAC Address Aging Timep.574.7.6.1 Theoryp.584.7.6.2 802.1X Configurationp.624.7.6.3 802.1X Client Configurationp.684.8 QoSp.714.8.1 Understand QOSp.714.8.2 QOS Configurationp.724.9 Multicastp.774.9.1 IGMP Snoopingp.774.9.2 IGMP Snooping Configurationp.784.9.3 IGMP Port Policyp.794.9.4 IGMP Group Policyp.814.9.5 Static Routing Portp.844.10 Port Analysisp.874.10.1 Port Analysisp.874.10.2 Port Mirrorp.874.11 Storm Controlp.884.12 IP Stackingp.894.12.1 About IP Stackingp.894.12.2 IP Stacking Configurationp.895.1 Incorrect connectionsp.945.1.1 Faulty or loose cablesp.945.1.2 Non-standard cablesp.945.1.3 Improper Network Topologiesp.945.2 Diagnosing LED Indicatorsp.945.2.1 Cablingp.956. APPENDIXp.966.1 Console Port Pin Assignmentsp.966.2 100BASE-TX/10BASE-T Pin Assignmentsp.977. APPENDIX-Bp.98802.1Q VLAN Multi-Untagged VLAN setting sample 1p.98802.1Q VLAN - Multi-Untagged VLAN setting sample 2p.101802.1Q VLAN - Multi-Untagged VLAN setting sample 3p.104
Page 1 of the Planet Technology WSD-800 user manual — WGSD-1022C 8-Port 10/100Mbps + 2 Gigabit TP/SFP Combo Managed Ethernet Switch
Page 1 · click to enlarge
Page 1
Planet Technology WSD-800 diagram (page 1)
Fig. 1

User's Manual

WSD-800

8-Port 10/100Mbps

WGSD-910 8-Port 10/100Mbps + 1 Gigabit TP/SFP Combo

Planet Technology WSD-800 — User's Manual diagram (page 1)
Fig. 2 · User's Manual

WGSD-1022C 8-Port 10/100Mbps + 2 Gigabit TP/SFP Combo Managed Ethernet Switch

Page 2 of the Planet Technology WSD-800 user manual — FOR MODELS: WSD-800 / WGSD-910 / WGSD-1022C
Page 2 · click to enlarge
Page 2

Copyright © PLANET Technology Corp. 2008.

Contents subject to which revision without prior notice.

PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective

owners.

PLANET Technology does not warrant that the hardware will work properly in all environments and applications,

and makes no warranty and representation, either implied or expressed, with respect to the quality, performance,

merchantability, or fitness for a particular purpose.

PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any

inaccuracies or omissions that may have occurred.

Information in this User's Manual is subject to change without notice and does not represent a commitment on the

part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's

Manual. PLANET makes no commitment to update or keep current the information in this User's Manual, and

reserves the right to make improvements to this User's Manual and/or to the products described in this User's

Manual, at any time without notice.

If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your

comments and suggestions.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference

when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate

radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause

harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause

harmful interference in which case the user will be required to correct the interference at whose own expense.

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the

user may be required to take adequate measures.

To avoid the potential effects on the environment and human health as a result of the

presence of hazardous substances in electrical and electronic equipment, end users of

electrical and electronic equipment should understand the meaning of the crossed-out

wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to

collect such WEEE separately.

PLANET Managed Ethernet Switch User's Manual

FOR MODELS: WSD-800 / WGSD-910 / WGSD-1022C

REVISION: 1.8 (AUGUST.2008)

Part No. 2081-A92310-002

Show 6 more labels / short text on this page
Trademarks · Disclaimer · FCC Warning · CE Mark Warning · WEEE Warning · Revision
Page 3 of the Planet Technology WSD-800 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

1. INTRODUCTIONp.61.1 Packet Contentsp.61.2 How to Use This Manualp.61.3 Product Featurep.71.4 Product Specificationp.72. INSTALLATIONp.102.1 Product Descriptionp.102.1.1 Product Overviewp.102.1.2 Switch Front Panelp.102.1.3 LED Indicationsp.112.1.4 Switch Rear Panelp.122.2 Install the Switchp.132.2.1 Desktop Installationp.132.2.2 Rack Mountingp.142.2.3 Installing the SFP transceiverp.153. CONSOLE MANAGEMENTp.173.1 Connecting to the Switchp.173.2 Login in the Console Interfacep.173.3 Console Managementp.183.4 Telnet loginp.193.5 Commandsp.193.5.1 First level commandsp.193.5.2 Privileged Commandp.203.5.2.1 Clear commandp.203.5.2.2 Copy commandp.213.5.2.3 Disable commandp.213.5.2.4 Reboot commandp.223.5.2.5 Set commandp.223.5.2.6 Show commandp.244. WEB-BASED MANAGEMENTp.264.1 About Web-based Managementp.264.2 Preparing for Web Managementp.264.3 System Loginp.264.4 Systemp.274.4.1 IP Configurationp.274.4.2 SNMPp.284.4.2.1 Theoryp.284.2.2.2 SNMP Configurationp.294.4.3 Passwordp.324.4.4 CONSOLEp.324.4.5 System Upgradep.324.4.6 Saving Parametersp.334.4.7 Parameters Backup & Recoveryp.334.4.8 Load Defaultp.344.4.9 Rebootp.344.5 Port Managementp.354.5.1 Port Configurationp.354.5.2 Port Statisticsp.354.5.3 Port Band Restrictp.364.6 Redundancyp.364.6.1 Spanning Treep.364.6.2 Spanning Tree Configurationp.424.6.3 Link Aggregationp.454.7 Securityp.464.7.1 VLANp.464.7.1.1 Theoryp.464.7.1.2 VLAN Configurationp.504.7.2 MAC Address Bindp.554.7.3 MAC Address Filteringp.564.7.4 MAC Address Learningp.574.7.5 MAC Address Aging Timep.574.7.6.1 Theoryp.584.7.6.2 802.1X Configurationp.624.7.6.3 802.1X Client Configurationp.684.8 QoSp.714.8.1 Understand QOSp.714.8.2 QOS Configurationp.724.9 Multicastp.774.9.1 IGMP Snoopingp.774.9.2 IGMP Snooping Configurationp.784.9.3 IGMP Port Policyp.794.9.4 IGMP Group Policyp.814.9.5 Static Routing Portp.844.10 Port Analysisp.874.10.1 Port Analysisp.874.10.2 Port Mirrorp.874.11 Storm Controlp.884.12 IP Stackingp.894.12.1 About IP Stackingp.894.12.2 IP Stacking Configurationp.895.1 Incorrect connectionsp.945.1.1 Faulty or loose cablesp.945.1.2 Non-standard cablesp.945.1.3 Improper Network Topologiesp.945.2 Diagnosing LED Indicatorsp.945.2.1 Cablingp.956. APPENDIXp.966.1 Console Port Pin Assignmentsp.966.2 100BASE-TX/10BASE-T Pin Assignmentsp.977. APPENDIX-Bp.98802.1Q VLAN Multi-Untagged VLAN setting sample 1p.98802.1Q VLAN - Multi-Untagged VLAN setting sample 2p.101802.1Q VLAN - Multi-Untagged VLAN setting sample 3p.104
Page 4 of the Planet Technology WSD-800 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

1. INTRODUCTIONp.61.1 Packet Contentsp.61.2 How to Use This Manualp.61.3 Product Featurep.71.4 Product Specificationp.72. INSTALLATIONp.102.1 Product Descriptionp.102.1.1 Product Overviewp.102.1.2 Switch Front Panelp.102.1.3 LED Indicationsp.112.1.4 Switch Rear Panelp.122.2 Install the Switchp.132.2.1 Desktop Installationp.132.2.2 Rack Mountingp.142.2.3 Installing the SFP transceiverp.153. CONSOLE MANAGEMENTp.173.1 Connecting to the Switchp.173.2 Login in the Console Interfacep.173.3 Console Managementp.183.4 Telnet loginp.193.5 Commandsp.193.5.1 First level commandsp.193.5.2 Privileged Commandp.203.5.2.1 Clear commandp.203.5.2.2 Copy commandp.213.5.2.3 Disable commandp.213.5.2.4 Reboot commandp.223.5.2.5 Set commandp.223.5.2.6 Show commandp.244. WEB-BASED MANAGEMENTp.264.1 About Web-based Managementp.264.2 Preparing for Web Managementp.264.3 System Loginp.264.4 Systemp.274.4.1 IP Configurationp.274.4.2 SNMPp.284.4.2.1 Theoryp.284.2.2.2 SNMP Configurationp.294.4.3 Passwordp.324.4.4 CONSOLEp.324.4.5 System Upgradep.324.4.6 Saving Parametersp.334.4.7 Parameters Backup & Recoveryp.334.4.8 Load Defaultp.344.4.9 Rebootp.344.5 Port Managementp.354.5.1 Port Configurationp.354.5.2 Port Statisticsp.354.5.3 Port Band Restrictp.364.6 Redundancyp.364.6.1 Spanning Treep.364.6.2 Spanning Tree Configurationp.424.6.3 Link Aggregationp.454.7 Securityp.464.7.1 VLANp.464.7.1.1 Theoryp.464.7.1.2 VLAN Configurationp.504.7.2 MAC Address Bindp.554.7.3 MAC Address Filteringp.564.7.4 MAC Address Learningp.574.7.5 MAC Address Aging Timep.574.7.6.1 Theoryp.584.7.6.2 802.1X Configurationp.624.7.6.3 802.1X Client Configurationp.684.8 QoSp.714.8.1 Understand QOSp.714.8.2 QOS Configurationp.724.9 Multicastp.774.9.1 IGMP Snoopingp.774.9.2 IGMP Snooping Configurationp.784.9.3 IGMP Port Policyp.794.9.4 IGMP Group Policyp.814.9.5 Static Routing Portp.844.10 Port Analysisp.874.10.1 Port Analysisp.874.10.2 Port Mirrorp.874.11 Storm Controlp.884.12 IP Stackingp.894.12.1 About IP Stackingp.894.12.2 IP Stacking Configurationp.895.1 Incorrect connectionsp.945.1.1 Faulty or loose cablesp.945.1.2 Non-standard cablesp.945.1.3 Improper Network Topologiesp.945.2 Diagnosing LED Indicatorsp.945.2.1 Cablingp.956. APPENDIXp.966.1 Console Port Pin Assignmentsp.966.2 100BASE-TX/10BASE-T Pin Assignmentsp.977. APPENDIX-Bp.98802.1Q VLAN Multi-Untagged VLAN setting sample 1p.98802.1Q VLAN - Multi-Untagged VLAN setting sample 2p.101802.1Q VLAN - Multi-Untagged VLAN setting sample 3p.104
Page 5 of the Planet Technology WSD-800 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

1. INTRODUCTIONp.61.1 Packet Contentsp.61.2 How to Use This Manualp.61.3 Product Featurep.71.4 Product Specificationp.72. INSTALLATIONp.102.1 Product Descriptionp.102.1.1 Product Overviewp.102.1.2 Switch Front Panelp.102.1.3 LED Indicationsp.112.1.4 Switch Rear Panelp.122.2 Install the Switchp.132.2.1 Desktop Installationp.132.2.2 Rack Mountingp.142.2.3 Installing the SFP transceiverp.153. CONSOLE MANAGEMENTp.173.1 Connecting to the Switchp.173.2 Login in the Console Interfacep.173.3 Console Managementp.183.4 Telnet loginp.193.5 Commandsp.193.5.1 First level commandsp.193.5.2 Privileged Commandp.203.5.2.1 Clear commandp.203.5.2.2 Copy commandp.213.5.2.3 Disable commandp.213.5.2.4 Reboot commandp.223.5.2.5 Set commandp.223.5.2.6 Show commandp.244. WEB-BASED MANAGEMENTp.264.1 About Web-based Managementp.264.2 Preparing for Web Managementp.264.3 System Loginp.264.4 Systemp.274.4.1 IP Configurationp.274.4.2 SNMPp.284.4.2.1 Theoryp.284.2.2.2 SNMP Configurationp.294.4.3 Passwordp.324.4.4 CONSOLEp.324.4.5 System Upgradep.324.4.6 Saving Parametersp.334.4.7 Parameters Backup & Recoveryp.334.4.8 Load Defaultp.344.4.9 Rebootp.344.5 Port Managementp.354.5.1 Port Configurationp.354.5.2 Port Statisticsp.354.5.3 Port Band Restrictp.364.6 Redundancyp.364.6.1 Spanning Treep.364.6.2 Spanning Tree Configurationp.424.6.3 Link Aggregationp.454.7 Securityp.464.7.1 VLANp.464.7.1.1 Theoryp.464.7.1.2 VLAN Configurationp.504.7.2 MAC Address Bindp.554.7.3 MAC Address Filteringp.564.7.4 MAC Address Learningp.574.7.5 MAC Address Aging Timep.574.7.6.1 Theoryp.584.7.6.2 802.1X Configurationp.624.7.6.3 802.1X Client Configurationp.684.8 QoSp.714.8.1 Understand QOSp.714.8.2 QOS Configurationp.724.9 Multicastp.774.9.1 IGMP Snoopingp.774.9.2 IGMP Snooping Configurationp.784.9.3 IGMP Port Policyp.794.9.4 IGMP Group Policyp.814.9.5 Static Routing Portp.844.10 Port Analysisp.874.10.1 Port Analysisp.874.10.2 Port Mirrorp.874.11 Storm Controlp.884.12 IP Stackingp.894.12.1 About IP Stackingp.894.12.2 IP Stacking Configurationp.895.1 Incorrect connectionsp.945.1.1 Faulty or loose cablesp.945.1.2 Non-standard cablesp.945.1.3 Improper Network Topologiesp.945.2 Diagnosing LED Indicatorsp.945.2.1 Cablingp.956. APPENDIXp.966.1 Console Port Pin Assignmentsp.966.2 100BASE-TX/10BASE-T Pin Assignmentsp.977. APPENDIX-Bp.98802.1Q VLAN Multi-Untagged VLAN setting sample 1p.98802.1Q VLAN - Multi-Untagged VLAN setting sample 2p.101802.1Q VLAN - Multi-Untagged VLAN setting sample 3p.104
Page 6 of the Planet Technology WSD-800 user manual — 1.2 How to Use This Manual
Page 6 · click to enlarge
Page 6

1. INTRODUCTION

1.1 Packet Contents

Check the contents of your package for following parts:

▫ Ethernet Switch x1

▫ CD-ROM user's manual x1

▫ Quick installation guide x1

▫ 19" rack mounting kit x1

▫ Power cord x1

▫ Rubber feet x 4

If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton

including the original packing material, and use them against to repack the product in case there is a need to

return it to us for repair.

1.2 How to Use This Manual

This User Manual is structured as follows:

The chapter explains the functions of the Switch and how to physically install the Switch.

Chapter 3, CONSOLE MANAGEMENT

The chapter explains how to manage the Switch by Console interface.

Chapter 4, WEB-BASED MANAGEMENT

The chapter explains how to manage the Switch by Web interface.

Chapter 5, TROUBLE SHOOTING

The chapter explains how to trouble shooting of the Switch.

The chapter contains cable information of the Switch.

In the following section, terms "Switch" means the three Switch devices, ie. WSD-800, WGSD-910 and

WGSD-1022C; Terms with lower case "switch" means any Ethernet switches.

Chapter 2, INSTALLATION · Chapter 6, APPENDIX

Page 7 of the Planet Technology WSD-800 user manual — 1.4 Product Specification
Page 7 · click to enlarge
Page 7

1.3 Product Feature

▫ Complies with IEEE 802.3, 10Base-T, IEEE 802.3u, 100Base-TX, IEEE 802.3ab, 1000Base-T, IEEE

802.3z, 1000Base-SX/LX

▫ 8-Port 10/100Mbps TP interfaces (WSD-800)

▫ 8-Port 10/100Mbps TP interfaces with 1 port Gigabit combo (WGSD-910)

▫ 8-Port 10/100Mbps TP interfaces with 2 port Gigabit combo (WGSD-1022C)

▫ High back-plane bandwidth 1.6Gbps / 3.6Gbps / 5.6Gbps (WSD-800 / WGSD-910 / WGSD-1022C)

▫ Configuration backup and recovery

▫ Per port Ingress/Egress bandwidth restriction

▫ IEEE 802.1d Spanning tree, 802.1w Rapid Spanning Tree

▫ Configurable spanning tree aging time, STP port configuration

▫ 4 trunk groups, up to 4 ports per trunk

▫ Port-based/802.1Q VLAN with 4K VLAN ID

▫ MAC Binding/Filtering/Learning, configurable MAC Aging time

▫ 8 mappings ID to 4 priority queues, Support MAC/VLAN/802.1p/Port to CoS mapping

▫ IGMP snooping and IGMP Query mode for Multi-media application

▫ Statistic Routing Port

▫ 1 to many Ingress/Egress Port mirror and Port analysis

▫ Broadcast/Multicast/Flooded storm control

▫ 802.1X Port-Based Authentication

▫ IP Stack Technology supports up to 8 units switch stack for centralize management

1.4 Product Specification

Planet Technology WSD-800 — 1.4 Product Specification diagram (page 7)
Fig. 3 · 1.4 Product Specification

Switch Fabric 1.6Gbos / non-blocking 3.6Gbps / non-blocking 5.6Gbps / non-blocking

▫ Console/Web/SNMP management

Page 8 of the Planet Technology WSD-800 user manual — 1.3 Product Feature
Page 8 · click to enlarge
Page 8
Planet Technology WSD-800 — 1.3 Product Feature diagram (page 8)
Fig. 4 · 1.3 Product Feature

Flow Control Back pressure for half duplex, IEEE 802.3x Pause Frame for full duplex

Console Interface One RS-232 DB-9 male connector for Switch management

Dimension (W x D x H) 280 x 173 x 44 mm

Management Interface Console, Telnet, Web Browser, SNMP v1 and v2c

Flow Control disable / enable. Bandwidth control on each port.

Display each port’s speed duplex mode, link status, Flow control status. Auto

IEEE 802.1Q Tagged Based VLAN , 4K VLAN ID,up to 255 VLAN groups

Link Aggregation Supports 4 groups of 8-Port trunk support

Traffic classification based on Port Number, 802.1p priority, DS/TOS field

Page 9 of the Planet Technology WSD-800 user manual — 1.3 Product Feature
Page 9 · click to enlarge
Page 9
SecurityMAC filtering and Binding, up to 400 rules RFC-1213 MIB-II RFC-2863 Interface MIB RFC-2665 EtherLike MIB RFC-1493 Bridge MIB RFC-2674 Extended Bridge MIB RFC-2819 RMON MIB (Group 1, 2, 3,9) RFC-2737 Entity MIB RFC-2618 RADIUS Client MIB SNMP MIBs Standards Conformance Regulation ComplianceFCC Part 15 Class A, CE IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000Base-T IEEE 802.3x Flow Control and Back pressure IEEE 802.1d Spanning tree protocol IEEE 802.1w Rapid spanning tree protocol IEEE 802.1p Class of service IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control Standards Compliance
Page 10 of the Planet Technology WSD-800 user manual — 2.1.2 Switch Front Panel
Page 10 · click to enlarge
Page 10

2. INSTALLATION

This section describes the functionalities of the Switch's components and guides how to install it on the desktop or

shelf. Basic knowledge of networking is assumed. Please read this chapter completely before continuing.

2.1 Product Description

2.1.1 Product Overview

With 8-Port 10/100Mbps, the PLANET WSD-800 / WGSD-910 / WGSD-1022C boast a high performance switch

architecture that is capable of providing non-blocking switch fabric and wire-speed throughput as high as 1.6Gbps

/ 3.6Gbps / 5.6Gbps.

The IEEE 802 standard-based firmware provides a rich set of features and ensures interoperability with equipment

from other vendors. Additionally, the firmware includes advanced features such as IGMP snooping, broadcast

storm control, and MAC address filtering, to enhance security and bandwidth utilization.

With its built-in Web-based management, the PLANET WSD-800 / WGSD-910 / WGSD-1022C offer an

easy-to-use, platform-independent management and configuration facility. The PLANET WSD-800 / WGSD-910 /

WGSD-1022C support standard Simple Network Management Protocol (SNMP) and can be managed via any

standard-based management software. For text-based management, the WSD-800 / WGSD-910 / WGSD-1022C

can also be accessed via Telnet and the console port.

2.1.2 Switch Front Panel

Figure 2-1 shows the front panel of WSD-800

Planet Technology WSD-800 — 2.1.2 Switch Front Panel diagram (page 10)
Fig. 5 · 2.1.2 Switch Front Panel

Figure 2-1 WSD-800 front panel.

Figure 2-2 shows the front panel of WGSD-910.

Planet Technology WSD-800 — 2.1.2 Switch Front Panel diagram (page 10)
Fig. 6 · 2.1.2 Switch Front Panel

Figure 2-2 WGSD-910 front panel.

Page 11 of the Planet Technology WSD-800 user manual — 2.1.3 LED Indications
Page 11 · click to enlarge
Page 11

Figure 2-3 shows the front panel of WGSD-1022C.

Planet Technology WSD-800 — 2.1.3 LED Indications diagram (page 11)
Fig. 7 · 2.1.3 LED Indications

Figure 2-3 WGSD-1022C front panel.

2.1.3 LED Indications

  • WSD-800
  • System
Planet Technology WSD-800 — 2.1.3 LED Indications diagram (page 11)
Fig. 8 · 2.1.3 LED Indications
LEDColorFunction WRGreenLights to indicate that the Switch is powered on. YSGreenLights to indicate the system is working.
  • Per 10/100Base-TX RJ-45 Port ( Port-1 to Port-8)
Planet Technology WSD-800 — 2.1.3 LED Indications diagram (page 11)
Fig. 9 · 2.1.3 LED Indications
LEDColorFunction NK/ACTOrangeBlink to indicate that the Switch is actively sending or receiving data over that port. DX/COLGreenLights to indicate respective port is in full duplex (FDX) mode. Otherwise, it is OFF for half duplex (HDX) operations. It blinking amber when collisions are occurring on the respective port. 00GreenLights to indicate the port is acting in 100Mbps speed, off to indicate the port is acting in 10Mbps.
  • WGSD-910 / WGSD-1022C
  • System
Planet Technology WSD-800 — 2.1.3 LED Indications diagram (page 11)
Fig. 10 · 2.1.3 LED Indications
LEDColorFunction PWRGreenLights to indicate that the Switch has power. SYSGreenLights to indicate the system is working.
  • Per 10/100Base-TX RJ-45 Port ( Port-1 to Port-8)
Planet Technology WSD-800 — 2.1.3 LED Indications diagram (page 11)
Fig. 11 · 2.1.3 LED Indications
LEDColorFunction NK/ACTGreenLights to indicate the link through that port is successfully established. Blink: indicate that the Switch is actively sending or receiving data over that port. SPEEDOrangeLights to indicate the port is running in 100Mbps speed. Off: indicate that the port is operating at 10Mbps.
Page 12 of the Planet Technology WSD-800 user manual — 2.1.4 Switch Rear Panel
Page 12 · click to enlarge
Page 12
  • Gigabit TP/SFP interface (Port-9, WGSD-910), (Port-9, Port-10, WGSD-1022C)
Planet Technology WSD-800 — 2.1.4 Switch Rear Panel diagram (page 12)
Fig. 12 · 2.1.4 Switch Rear Panel
LEDColorFunction LNK/ACTGreenLights to indicate the link through that port is successfully established. Blink: indicate that the Switch is actively sending or receiving data over that port. SPEEDOrangeLights to indicate the port is running in 1000Mbps speed. Off: indicate that the port is operating at 10Mbps or 100Mbps.

2.1.4 Switch Rear Panel

Figure 2-4 shows the rear panel of WSD-800.

Planet Technology WSD-800 — 2.1.4 Switch Rear Panel diagram (page 12)
Fig. 13 · 2.1.4 Switch Rear Panel

Figure 2-4 WSD-800 rear panel.

Figure 2-5 shows the rear panel of WGSD-910 / WGSD-1022C.

Planet Technology WSD-800 — 2.1.4 Switch Rear Panel diagram (page 12)
Fig. 14 · 2.1.4 Switch Rear Panel

Figure 2-5 WGSD-910 / WGSD-1022C rear panel.

Power Notice:

1. The device is a power-required device, it means, it will not work till it is powered. If

your networks should active all the time, please consider using UPS (Uninterrupted

Power Supply) for your device. It will prevent you from network data loss or network

downtime.

2. In some area, installing a surge suppression device may also help to protect your

Switch from being damaged by unregulated surge or current to the Switch or the

power adapter.

Page 13 of the Planet Technology WSD-800 user manual — " Note :
Page 13 · click to enlarge
Page 13

2.2 Install the Switch

This section describes how to install the Ethernet Switch and make connections to it. Please read the following

topics and perform the procedures in the order being presented.

2.2.1 Desktop Installation

To install the Switch on desktop or shelf, please follows these steps:

1. Attach the rubber feet to the recessed areas on the bottom of the Switch.
2. Place the Switch on the desktop or the shelf near an AC power source.
3. Keep enough ventilation space between the Switch and the surrounding objects.
Planet Technology WSD-800 — 2.2.1 Desktop Installation diagram (page 13)
Fig. 15 · 2.2.1 Desktop Installation

Figure 2-6 Attaching the rubber feet to the Switch

When choosing a location, please keep in mind the environmental restrictions discussed in

" Note :

Chapter 1, Section 4, in Specification

4. Connect the Switch to network devices.

A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the Switch

B. Connect the other end of the cable to the network devices such as printer servers, workstations or

routers…etc.

Connection to the Switch requires UTP Category 5 network cabling with RJ-45 tips. For more

" Note :

information, please see the Cabling Specification in Appendix A.

5. Supply power to the Switch.

A. Connect one end of the power cable to the Switch.

B. Connect the power plug of the power cable to a standard wall outlet.

When the Switch receives power, the Power LED should remain solid Green.

Page 14 of the Planet Technology WSD-800 user manual — 2.2.2 Rack Mounting
Page 14 · click to enlarge
Page 14

2.2.2 Rack Mounting

To install the Switch in a 19-inch standard rack, please follows the instructions described below.

1. Place the Switch on a hard flat surface, with the front panel positioned towards the front side.
2. Attach the rack-mount bracket to each side of the Switch with supplied screws attached to the package.

Figure 2-7 shows how to attach brackets to one side of the Switch.

Planet Technology WSD-800 — 2.2.2 Rack Mounting diagram (page 14)
Fig. 16 · 2.2.2 Rack Mounting

Figure 2-7 Attach brackets to the Switch.

You must use the screws supplied with the mounting brackets. Damage caused to the parts by

using incorrect screws would invalidate the warranty.

3. Secure the brackets tightly.
4. Follow the same steps to attach the second bracket to the opposite side.
5. After the brackets are attached to the Switch, use suitable screws to securely attach the brackets to the

rack, as shown in Figure 2-8.

Planet Technology WSD-800 — 2.2.2 Rack Mounting diagram (page 14)
Fig. 17 · 2.2.2 Rack Mounting

Figure 2-8 Mounting the Switch in a Rack

6. Proceeds with the steps 4 and steps 5 of session 2.2.1 Desktop Installation to connect the network cabling

and supply power to the Switch.

Page 15 of the Planet Technology WSD-800 user manual — # Notice:
Page 15 · click to enlarge
Page 15

2.2.3 Installing the SFP transceiver

The sections describe how to insert an SFP transceiver into an SFP slot.

The SFP transceivers are hot-pluggable and hot-swappable. You can plug-in and out the transceiver to/from any

SFP port without having to power down the Switch. As the Figure 2-9 appears.

Planet Technology WSD-800 — 2.2.3 Installing the SFP transceiver diagram (page 15)
Fig. 18 · 2.2.3 Installing the SFP transceiver

Figure 2-9 Plug-in the SFP transceiver

Approved PLANET SFP Transceivers

PLANET WGSD-910 / WGSD-1022C support both single mode and multi mode SFP transceiver. The following list

of approved PLANET SFP transceivers is correct at the time of publication:

  • MGB-SX SFP (1000Base-SX SFP transceiver )
  • MGB-LX SFP (1000Base-LX SFP transceiver )

# Notice:

It recommends using PLANET SFPs on the Switch. If you insert a SFP transceiver that is not

supported, the Switch will not recognize it.

Before connect the other switches, workstation or Media Converter.

1. Make sure both side of the SFP transfer are with the same media type, for example: 1000Base-SX to

1000Base-SX, 1000Bas-LX to 1000Base-LX.

2. Check the fiber-optic cable type match the SFP transfer model.

¾ To connect to 1000Base-SX SFP transceiver, use the multi-mode fiber cable- with one side must be

male duplex LC connector type.

¾ To connect to 1000Base-LX SFP, transceiver use the single-mode fiber cable-with one side must be

male duplex LC connector type.

Page 16 of the Planet Technology WSD-800 user manual — # Notice:
Page 16 · click to enlarge
Page 16

Connect the fiber cable

1. Attach the duplex LC connector on the network cable into the SFP transceiver.
2. Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a

Media Converter.

3. Check the LNK/ACT LED of the SFP slot on the front of the Switch. Ensure that the SFP transceiver is

operating correctly.

4. Check the Link mode of the SFP port if the link failed. Co works with some fiber-NICs or Media Converters,

set the Link mode to “1000 Force” is needed.

Remove the transceiver module

1. Make sure there is no network activity by consult or check with the network administrator. Or through the

management interface of the switch/converter (if available) to disable the port in advance.

2. Remove the Fiber Optic Cable gently.
3. Turn the handle of the MGB module to horizontal.
4. Pull out the module gently through the handle.
Planet Technology WSD-800 — 2.2.3 Installing the SFP transceiver diagram (page 16)
Fig. 19 · 2.2.3 Installing the SFP transceiver

Figure 2-10 Pull out the SFP transceiver

# Notice:

Never pull out the module without pull the handle or the push bolts on the module. Direct pull

out the module with violent could damage the module and SFP module slot of the device.

Page 17 of the Planet Technology WSD-800 user manual — 3.2 Login in the Console Interface
Page 17 · click to enlarge
Page 17

3. CONSOLE MANAGEMENT

3.1 Connecting to the Switch

The console port is a female DB-9 connector that enables a connection to a PC or terminal for monitoring and

configuring the Switch. Use the supplied RS-232 cable with a male DB-9 connector to connect a terminal or PC to

the Console port. The Console configuration (out of band) allows you to set Switch for remote terminal as if the

console terminal were directly connected to it.

Planet Technology WSD-800 — 3. CONSOLE MANAGEMENT diagram (page 17)
Fig. 20

3.2 Login in the Console Interface

When the connection between Switch and PC is ready, turn on the PC and run a terminal emulation program or

Hyper Terminal and configure its communication parameters to match the following default characteristics of the

console port:

Planet Technology WSD-800 — 3.2 Login in the Console Interface diagram (page 17)
Fig. 21 · 3.2 Login in the Console Interface
Baud Rate9600 bps
Data Bits8
Paritynone
Stop Bit1
Flow controlNone

The settings of communication parameters

Page 18 of the Planet Technology WSD-800 user manual — 3.3 Console Management
Page 18 · click to enlarge
Page 18

After finished the parameter settings, click “OK“. When the prompt shows “Switch>”, type “?” for help or type

“enable” for further configuration. The system needs password for further configuration. After the “enable”

command, the system asks for password, please enter “admin” for the default password. As shows in the

following screen:

Planet Technology WSD-800 — 3.3 Console Management diagram (page 18)
Fig. 22 · 3.3 Console Management

3.3 Console Management

Entering a question mark "?" at the prompt displays the list of commands available for command mode.

As shows in the following screen:

Planet Technology WSD-800 — 3.3 Console Management diagram (page 18)
Fig. 23 · 3.3 Console Management

The question mark “?” command

Console login screen

Page 19 of the Planet Technology WSD-800 user manual — 3.5.1 First level commands
Page 19 · click to enlarge
Page 19

3.4 Telnet login

The Switch also supports telnet for remote management. The Switch asks for user name and password for remote

login when using telnet, please use “admin” for username and “admin” for password.

3.5 Commands

There are two levels for console commands. The first level provides commands to show system informations and

current configurations. The second level (privileged mode) provides commands to set clear and show the

configuration.

3.5.1 First level commands

The follow table lists the first commands and the equivalent usages.

enable Enable privileged mode

show channel Show channel information

show console-info Show console-info

show dow1x local-userInfo Show dot1x local user information

show dot1x state Show dot1x information

show igmp-snooping group number show igmp snooping group-limit

show igmp-snooping group policy Show igmp snooping group policy

show igmp-snooping info Show igmp snooping information

show igmp-snooping policy deny Show igmp snooping policy deny

show ip http server Show http server information

show ip telnet server Show telnet server information

show ipstack info Show ip stack information

show mirror Show mirror information

show multicast router Show multicast router port information

show port counter Show port counter information

show port dot1x Show port dot1x information

show port mac-learning Show MACs on certain port

show port rate-shaping Show port ingress and egress rate-shaping

show port rstp-extension Show port RSTP port role and protocol mode

show port spantree Show spantree information on ports

show port state Show port infomation

show port storm-limit Show port storm limit mode and rate

show qos map cos-queue-map Show qos map cos-queue-map

Command Description

Page 20 of the Planet Technology WSD-800 user manual — 3.5.2.1 Clear command
Page 20 · click to enlarge
Page 20
Planet Technology WSD-800 — 3.5.2 Privileged Command diagram (page 20)
Fig. 24 · 3.5.2 Privileged Command

3.5.2 Privileged Command

To access to the second level, enter the “enable” command in the first level. The sysem then prompt for a

password. Please enter “admin” for the password.

The promt then changes to “Switch\enable>”. Entering a question mark "?" at the prompt displays the list of

commands available for command mode.

3.5.2.1 Clear command

Clear command is to clear the parameter. The follow table lists the clear commands and the equivalent usages.

Planet Technology WSD-800 — 3.5.2.1 Clear command diagram (page 20)
Fig. 25 · 3.5.2.1 Clear command

clear igmp-snooping policy deny Clear igmp snooping policy deny

clear mirror monitored-port egress Clear egress monitored port for mirror

clear mirror monitored-port ingress Clear ingress monitored port for mirror

clear port spantree portcost Restore spanning tree port cost to default value

Page 21 of the Planet Technology WSD-800 user manual — 3.5.2.3 Disable command
Page 21 · click to enlarge
Page 21
Planet Technology WSD-800 — 3.5.2.2 Copy command diagram (page 21)
Fig. 26 · 3.5.2.2 Copy command

clear port spantree portpri Restore spanning tree port priority to default value

clear port storm-limit Clear strom limit of all ports

clear qos map cos-queue-map Reset cos-queue map to default

clear qos map dot1p-cos-map Reset dot1p_cos map to default

copy config flash Copy system configuration parameters to default value

clear port storm-limit Clear strom limit of all ports

clear qos map cos-queue-map Reset cos-queue map to default

clear qos map dot1p-cos-map Reset dot1p_cos map to default

3.5.2.2 Copy command

Once the configuration is changed, it remains the original after a reboot unless the configuration is saved. Copy

command is to save the current configuration to the flash; this saves the configuration to next reboot.

copy config flash Copy system configuration parameters to flash

3.5.2.3 Disable command

Disable command is to exit the privileged mode and back to the first level of command line interface.

Disable Disable privileged mode

Command Description · Command Description

Page 22 of the Planet Technology WSD-800 user manual — 3.5.2.5 Set command
Page 22 · click to enlarge
Page 22

3.5.2.4 Reboot command

Reboot command is to reboot the Switch, please beware to check if the configuration is saved..

3.5.2.5 Set command

Set command is to change the parameter of the Switch functions. The follow table lists the set commands and the

equivalent usages.

Planet Technology WSD-800 — 3.5.2.5 Set command diagram (page 22)
Fig. 27 · 3.5.2.5 Set command

set dot1x max-req Max times of re-transmit EAP request to Supplicant

set enable password Set the password for the privileged level of the CLI

set igmp-snooping group number Set number of goups that a port can join in

set igmp-snooping immediate-leave Disable & Enable igmp snooping immediate-leave

set igmp-snooping policy deny Set igmp snooping policy deny

Command Description · Reboot Reboot system

Page 23 of the Planet Technology WSD-800 user manual — 3.5.2.4 Reboot command
Page 23 · click to enlarge
Page 23
Planet Technology WSD-800 — 3.5.2.4 Reboot command diagram (page 23)
Fig. 28 · 3.5.2.4 Reboot command

set mirror capture-port Set a port to capture traffic

set port rate-shaping egress Set port egress rate-shaping rate

set port rate-shaping ingress Set port ingress rate-shaping rate

set port rate-shaping egress Set port egress rate-shaping rate

set port rate-shaping ingress Set port ingress rate-shaping rate

set port spantree portco Set spanning tree port cost

set port spantree portfa Set spanning tree PortFast feature

set port spantree portpr Set spanning tree port priority

set port storm-limit mode Set port storm limit mode

set port storm-limit rate Set port storm limit rate

set qos map cos-queue-map Set the queue number of each cos

set qos map dot1p-cos-map Set the cos value of each dot1p priority

set radius key Set share key for radius server

Page 24 of the Planet Technology WSD-800 user manual — 3.5.2.6 Show command
Page 24 · click to enlarge
Page 24
Planet Technology WSD-800 — 3.5.2.6 Show command diagram (page 24)
Fig. 29 · 3.5.2.6 Show command

set spantree fwddelay Set the forward delay for the spanning tree

set spantree hello Set the hello interval for the spanning tree

set spantree maxage Set the max age interval for the spanning

set spantree priority Set the bridge priority for the spanning tree

set system management-vlan Specify a vlan for system management

set vlan type port-based Set system be port-based vlan

set vlan type dot1q-based Set system be dot1q-based vlan

3.5.2.6 Show command

Show command is to display the current parameter of the Switch functions. The follow table lists the show

commands and the equivalent usages.

Planet Technology WSD-800 — 3.5.2.6 Show command diagram (page 24)
Fig. 30 · 3.5.2.6 Show command

show igmp-snooping policy deny Show igmp snooping policy deny

Page 25 of the Planet Technology WSD-800 user manual — 3.5.2.6 Show command
Page 25 · click to enlarge
Page 25
Planet Technology WSD-800 — 3.5.2.6 Show command diagram (page 25)
Fig. 31 · 3.5.2.6 Show command

show port rate-shaping Show port ingress and egress rate-shaping

show port storm-limit Show port storm limit mode and rate

Page 26 of the Planet Technology WSD-800 user manual — # Notice:
Page 26 · click to enlarge
Page 26

4. WEB-BASED MANAGEMENT

This section introduces the configuration and functions of the Web-Based management.

4.1 About Web-based Management

The Switch offers management features that allow users to manage the Switch from anywhere on the network

through a standard browser such as Microsoft Internet Explorer.

The Web-Based Management supports Internet Explorer 6.0. It is based on Java Applets with an aim to reduce

network bandwidth consumption, enhance access speed and present an easy viewing screen.

# Notice:

By default, IE6.0 or later version does not allow Java Applets to open sockets. The user has to explicitly modify the

browser setting to enable Java Applets to use network ports.

4.2 Preparing for Web Management

Before use web management, you can use console to login the Switch and checking the default IP address of the

Switch. Please refer to Console Management Chapter for console login. If you need change IP address in first

time, you can use console mode to modify it. The default value is as below:

IP Address192.168.0.100
Subnet Mask255.255.255.0
Default Gateway0.0.0.0
User Nameadmin
Passwordadmin

4.3 System Login

1. Launch the Internet Explorer.
2. Enter the IP address of the Switch.
3. When the login screen appears, use admin as the default username/password respectively to login.
4. The main web page of the Web-based management appears. As shows in the following screen.

# Notice:

The following section will base on the console screens of WSD-800, for WGSD-910 / WGSD-1022C the display will be the same to WSD-800.

Page 27 of the Planet Technology WSD-800 user manual — 4.4 System
Page 27 · click to enlarge
Page 27
Planet Technology WSD-800 — 4.4 System diagram (page 27)
Fig. 32 · 4.4 System
Planet Technology WSD-800 — 4.4 System diagram (page 27)
Fig. 33 · 4.4 System

WSD-800 Web Management Interface

4.4 System

4.4.1 IP Configuration

The Switch can be managed by the Web/Telnet/SNMP interfaces. Administrators can access the management

interface via the IP address of the Switch. The default IP address of the Switch is 192.168.0.100. You can change

the IP address to be in the same IP segment as your LAN network for convinence.

To change the IP address, click on the System / IP Address menu button. The IP address configuration screen

then shows in the main page on the web. Enter the new IP address, Submask and Gateway then click on the OK

button to change.

Page 28 of the Planet Technology WSD-800 user manual — 4.4.2.1 Theory
Page 28 · click to enlarge
Page 28
Planet Technology WSD-800 — 4.4.2 SNMP diagram (page 28)
Fig. 34
Planet Technology WSD-800 — 4.4.2 SNMP diagram (page 28)
Fig. 35

NOTE:

1. The Switch’s factory-default IP address is 192.168.0.100 with Submask 255.255.255.0 and a default

gateway of 192.168.0.254

2. The changed IP address take effect immediately after click on the OK button, you need to use the new

IP address to access the Web interface.

3. The changed IP address remains the original after reboot the Switch unless the configuration is saved.

To save the changed IP address, please move to System/Saving Parameters menu.

4.4.2 SNMP

4.4.2.1 Theory

The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of

management information between network devices. It is part of the Transmission Control Protocol/Internet

Protocol (TCP/IP) protocol suite. SNMP enables network administrators to manage network performance, find and

solve network problems, and plan for network growth.

An SNMP-managed network consists of three key components: Network management stations (NMSs), SNMP

agents, Management information base (MIB) and network-management protocol:

。 Network management stations (NMSs)Sometimes called consoles, these devices execute management

applications that monitor and control network elements. Physically, NMSs are usually engineering

workstation-caliber computers with fast CPUs, megapixel color displays, substantial memory, and abundant

disk space. At least one NMS must be present in each managed environment.

。 AgentsAgents are software modules that reside in network elements. They collect and store management

information such as the number of error packets received by a network element.

。 Management Information Base (MIB)A MIB is a collection of managed objects residing in a virtual

information store. Collections of related managed objects are defined in specific MIB modules.

。 Network-management protocolA management protocol is used to convey management information

between agents and NMSs. SNMP is the Internet community's de facto standard management protocol.

IP Address Configuration

Page 29 of the Planet Technology WSD-800 user manual — 4.2.2.2 SNMP Configuration
Page 29 · click to enlarge
Page 29

SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving a

response.

。 Get -- Allows the NMS to retrieve an object instance from the agent.

。 Set -- Allows the NMS to set values for object instances within an agent.

。 Trap -- Used by the agent to asynchronously inform the NMS of some event. The SNMPv2 trap message is

designed to replace the SNMPv1 trap message.

An SNMP community is the group that devices and management stations running SNMP belong to. It helps define

where information is sent. The community name is used to identify the group. A SNMP device or agent may belong

to more than one SNMP community. It will not respond to requests from management stations that do not belong

to one of its communities. SNMP default communities are:

。 Write = private

。 Read = public

4.2.2.2 SNMP Configuration

To configure SNMP management, click on System/SNMP menu button, and the web main page changes to the

SNMP Management function, as shows in the following:

Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 29)
Fig. 36 · 4.2.2.2 SNMP Configuration

The followings are the description of the sub-table.

1. SNMP Agent Status Configuration

This block enables to turn on SNMP Agent.

Enabled / Disabled: To turn on or turn off the SNMP function on the Switch.

SNMP Operations · SNMP community

Page 30 of the Planet Technology WSD-800 user manual — 4.2.2.2 SNMP Configuration
Page 30 · click to enlarge
Page 30
Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 30)
Fig. 37 · 4.2.2.2 SNMP Configuration
2. System Options

This table is to define the system name, system location and the contact person of the Switch. These informations

show in the SNMP software of the management workstation which helps to identify the Switch that is looking into.

There are three fields in the “system options” configuration block:

。 System Name: The system name of the Switch which would show in the SNMP software.

。 System Location: The system location of the Switch which would show in the SNMP software.

。 Contact: The contact person of the Switch which would show in the SNMP software.

Fill the fileds and click on the “OK” button to save.

Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 30)
Fig. 38 · 4.2.2.2 SNMP Configuration
3. Community Configuration

Use this table to configure the SNMP community strings and define the policy of the relative string. The community

string acts like a password to permit access to the agent on the Switch. One or more of the following

characteristics can be associated with the community string:

。 Add Communityenter private or public

。 Chooses community strings for the Switch management access: read only or read/write

„ Read only: Enables requests accompanied by this string to display MIB-object information.

„ Read/WriteEnables requests accompanied by this string to display MIB-object information and to set MIB

objects.

Complete the above steps and click on the “Add” button.

Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 30)
Fig. 39 · 4.2.2.2 SNMP Configuration

The added string then shows in the Current Communities field.

z Current Communitiesshow the list in input field
Page 31 of the Planet Technology WSD-800 user manual — 4.2.2.2 SNMP Configuration
Page 31 · click to enlarge
Page 31
Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 31)
Fig. 40 · 4.2.2.2 SNMP Configuration
4. Management Station Configuration

A trap manager is a management station (SNMP application) that receives traps (the system alerts generated by

the Switch). If no trap manager is defined, no traps are issued. Create a trap manager by entering the IP address

of the station and a community string.

。 Enter Network management stations IP address: 192.168.0.53 (for example)

。 Trap Communitymust be the same string as “Add community”

Then click on “Add” button.

Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 31)
Fig. 41 · 4.2.2.2 SNMP Configuration

The “Current Management Stations” field shows the trap list.

Planet Technology WSD-800 — 4.2.2.2 SNMP Configuration diagram (page 31)
Fig. 42 · 4.2.2.2 SNMP Configuration
Page 32 of the Planet Technology WSD-800 user manual — 4.4.5 System Upgrade
Page 32 · click to enlarge
Page 32

4.4.3 Password

The Password management menu is to set or change the password of the Web Management Interface.

Click on System/Password menu button, and the Modify Password table shows in the main web page.

Enter “old password “, “new password”, “confirm password” Click “OK” to change the password.

Planet Technology WSD-800 — 4.4.3 Password diagram (page 32)
Fig. 43 · 4.4.3 Password

4.4.4 CONSOLE

This function shows the connection parameters for the Console Management Interface. Click on the

System/CONSOLE menu button, and the following table shows in the main page of the web.

Planet Technology WSD-800 — 4.4.4 CONSOLE diagram (page 32)
Fig. 44

4.4.5 System Upgrade

This function allows performing firmware update from the web interface.

Click on the System/System Upgrade menu button, and the following table shows in the main page of the web.

Click on the “Browse” button of the main page, the system would pop up the file selection menu to choose

firmware. Select on the firmware, and the Update Status would show the file upload status.

Planet Technology WSD-800 — 4.4.5 System Upgrade diagram (page 32)
Fig. 45 · 4.4.5 System Upgrade
Planet Technology WSD-800 — 4.4.5 System Upgrade diagram (page 32)
Fig. 46 · 4.4.5 System Upgrade
Page 33 of the Planet Technology WSD-800 user manual — 4.4.7 Parameters Backup & Recovery
Page 33 · click to enlarge
Page 33

4.4.6 Saving Parameters

It takes effect immediately when you change the parameters of the management function when the Switch is

running. But the parameters would not be saved after reboot the Switch. To keep the changed parameters, Click

on the System/Saving Parameters menu button, and click on the “Save” button on the web main page as show

in the following.

Planet Technology WSD-800 — 4.4.6 Saving Parameters diagram (page 33)
Fig. 47 · 4.4.6 Saving Parameters

4.4.7 Parameters Backup & Recovery

This function is to backup the running configuration to the workstation and to restore the configuration you had saved in the workstation.

Click on the System/Backup & Recovering menu button, and the following table shows in the web main page.

Planet Technology WSD-800 — 4.4.7 Parameters Backup & Recovery diagram (page 33)
Fig. 48 · 4.4.7 Parameters Backup & Recovery

To backup the running configuration, click on the “Backup the system’s parameters” link, and a pop up window

shows to save the configuration of the Switch to your workstation.

To recover a saved configuration, click on the “Browse” button in the Parameters Recovery table. A pop up

window would direct you to upload the configuration file.

Page 34 of the Planet Technology WSD-800 user manual — 4.4.9 Reboot
Page 34 · click to enlarge
Page 34

4.4.8 Load Default

This function is to reset the configuration of Switch to the factory default. Click on the System/Load Default menu

button, and the following table shows in the web main page.

Planet Technology WSD-800 — 4.4.8 Load Default diagram (page 34)
Fig. 49 · 4.4.8 Load Default
Planet Technology WSD-800 — 4.4.8 Load Default diagram (page 34)
Fig. 50 · 4.4.8 Load Default

4.4.9 Reboot

This function is to reboot the system.

Planet Technology WSD-800 — 4.4.9 Reboot diagram (page 34)
Fig. 51 · 4.4.9 Reboot
Page 35 of the Planet Technology WSD-800 user manual — 4.5.2 Port Statistics
Page 35 · click to enlarge
Page 35

4.5 Port Management

4.5.1 Port Configuration

This function is to configure and to view the configured port management status, port negotiation mode and the

port flow control function.

。 Management Status: Display port status: Enable or Disable. Disable is to turn off the port.

。 Link Status: “Up” to indicate the port is linked while “Down” to indicate the port is not connectd.

。 Speed: Shows the negotiation mode and the running speed on the port.

。 Duplex: Displays full-duplex or half-duplex mode.

。 Flow Control: Display Flow status of port: Enable or Disable, Disable indicates Flow control is off.

。 AutoDisplay which mode the port is auto-negotiated

。 Config: (configured) Displays the state defined by the user.

。 Atual: Displays the negotiation result.

Planet Technology WSD-800 — 4.5 Port Management diagram (page 35)
Fig. 52 · 4.5 Port Management

4.5.2 Port Statistics

The Port Statistics page provides a view of the current status of every port on the Switch. Pressing the “Reset”

button will reset all port counters to zero.

Planet Technology WSD-800 — 4.5.2 Port Statistics diagram (page 35)
Fig. 53 · 4.5.2 Port Statistics
Page 36 of the Planet Technology WSD-800 user manual — 1. Spanning Tree Protocol
Page 36 · click to enlarge
Page 36

4.5.3 Port Band Restrict

The function provides the In-Band and Out-Band connection speed restriction on the ports. The Band of the

connection speed rangs from 64Kbps to 80000Kbps.

Ingress Port List/Egress Port List field can be filled in distinct number or a port range. For example, you can fill

with “1, 3” for port 1 and port 3 and “3-5” for port 3 to port 5.

Band(64~80000Kbps) field can be filled with any number between 64 and 80000.

Planet Technology WSD-800 — 4.5.3 Port Band Restrict diagram (page 36)
Fig. 54 · 4.5.3 Port Band Restrict
Planet Technology WSD-800 — 4.5.3 Port Band Restrict diagram (page 36)
Fig. 55 · 4.5.3 Port Band Restrict

Due to the Chipset limition, set the band rate large then 500Kbps at In-Band Restrict field.

NOTICE:

If this value is less than 500Kbps and the packet will drop on that time.

And please also be remined, enable flow control at specific port is required.

4.6 Redundancy

4.6.1 Spanning Tree

1. Spanning Tree Protocol

The IEEE 802.1D Spanning Tree Protocol and IEEE 802.1W Rapid Spanning Tree Protocol allow for the blocking

of links between switches that form loops within the network. When multiple links between switches are detected,

a primary link is established. Duplicated links are blocked from use and become standby links. The protocol allows

for the duplicate links to be used in the event of a failure of the primary link. Once the Spanning Tree Protocol is

configured and enabled, primary links are established and duplicated links are blocked automatically. The

reactivation of the blocked links (at the time of a primary link failure) is also accomplished automatically without

operator intervention.

This automatic network reconfiguration provides maximum uptime to network users. However, the concepts of the

Page 37 of the Planet Technology WSD-800 user manual — 4.5.3 Port Band Restrict
Page 37 · click to enlarge
Page 37

Spanning Tree Algorithm and protocol are a complicated and complex subject and must be fully researched and

understood. It is possible to cause serious degradation of the performance of the network if the Spanning Tree is

incorrectly configured. Please read the following before making any changes from the default values.

The Switch STP performs the following functions:

。 Creates a single spanning tree from any combination of switching or bridging elements.

。 Creates multiple spanning trees – from any combination of ports contained within a single Switch, in user

specified groups.

。 Automatically reconfigures the spanning tree to compensate for the failure, addition, or removal of any

element in the tree.

。 Reconfigures the spanning tree without operator intervention.

Bridge Protocol Data Units

For STP to arrive at a stable network topology, the following information is used:

。 The unique Switch identifier

。 The path cost to the root associated with each switch port

。 The por tidentifier

STP communicates between switches on the network using Bridge Protocol Data Units (BPDUs). Each BPDU

contains the following information:

。 The unique identifier of the Switch that the transmitting Switch currently believes is the root Switch

。 The path cost to the root from the transmitting port

。 The port identifier of the transmitting port

The Switch sends BPDUs to communicate and construct the spanning-tree topology. All switches connected to the

LAN on which the packet is transmitted will receive the BPDU. BPDUs are not directly forwarded by the Switch,

but the receiving Switch uses the information in the frame to calculate a BPDU, and, if the topology changes,

initiates a BPDU transmission.

The communication between switches via BPDUs results in the following:

。 One Switch is elected as the root Switch

。 The shortest distance to the root Switch is calculated for each Switch

。 A designated Switch is selected. This is the Switch closest to the root Switch through which packets will be

forwarded to the root.

。 A port for each Switch is selected. This is the port providing the best path from the Switch to the root Switch.

。 Ports included in the STP are selected.

Creating a Stable STP Topology

It is to make the root port a fastest link. If all switches have STP enabled with default settings, the Switch with the

lowest MAC address in the network will become the root Switch. By increasing the priority (lowering the priority

number) of the best switch, STP can be forced to select the best switch as the root Switch.

When STP is enabled using the default parameters, the path between source and destination stations in a

switched network might not be ideal. For instance, connecting higher-speed links to a port that has a higher

number than the current root port can cause a root-port change.

Page 38 of the Planet Technology WSD-800 user manual — 4.5.3 Port Band Restrict
Page 38 · click to enlarge
Page 38

The BPDUs take some time to pass through a network. This propagation delay can result in topology changes

where a port that transitioned directly from a Blocking state to a Forwarding state could create temporary data

loops. Ports must wait for new network topology information to propagate throughout the network before starting to

forward packets. They must also wait for the packet lifetime to expire for BPDU packets that were forwarded based

on the old topology. The forward delay timer is used to allow the network topology to stabilize after a topology

change. In addition, STP specifies a series of states a port must transition through to further ensure that a stable

network topology is created after a topology change.

Each port on a switch using STP exists is in one of the following five states:

。 Blocking – the port is blocked from forwarding or receiving packets

。 Listening – the port is waiting to receive BPDU packets that may tell the port to go back to the blocking

。 Learning – the port is adding addresses to its forwarding database, but not yet forwarding packets

。 Forwarding – the port is forwarding packets

。 Disabled – the port only responds to network management messages and must return to the blocking state

A port transitions from one state to another as follows:

。 From initialization (switch boot) to blocking

。 From blocking to listening or to disabled

。 From listening to learning or to disabled

。 From learning to forwarding or to disabled

。 From forwarding to disabled

。 From disabled to blocking

STP Port State Transitions

Show 9 more labels / short text on this page
STP Port States · state · first · Switch · Blocking · Listening · Disable · Learning · Forwarding
Page 39 of the Planet Technology WSD-800 user manual — 32768 + MAC
Page 39 · click to enlarge
Page 39

You can modify each port state by using management software. When you enable STP, every port on every switch

in the network goes through the blocking state and then transitions through the states of listening and learning at

power up. If properly configured, each port stabilizes to the forwarding or blocking state. No packets (except

BPDUs) are forwarded from, or received by, STP enabled ports until the forwarding state is enabled for that port.

2. STP Parameters

The Switch allows for two levels of operation: the Switch level and the port level. The level forms a spanning tree

consisting of links between one or more switches. The port level constructs a spanning tree consisting of groups of

one or more ports. The STP operates in much the same way for both levels.

Planet Technology WSD-800 — 2. STP Parameters diagram (page 39)
Fig. 56 · 2. STP Parameters

Root Bridge and the Designated Bridges.

On the port level, STP sets the Root Port and the Designated Ports.

The following are the user-configurable STP parameters for the switch level:

Parameter Description Default Value

A combination of the User-set priority and

32768 + MAC

the Switch’s MAC address.

except by setting priority

The Bridge Identifier consists of two parts:

a 16-bit priority and a 48-bit Ethernet MAC

address 32768 + MAC

A relative priority for each switch – lower

numbers give a higher priority and a greater

chance of a given switch being elected as

Hello Time The length of time between broadcasts of

the hello message by the Switch

Measures the age of a received BPDU for a

port and ensures that the BPDU is discarded

when its age exceeds the value of the

maximum age timer.

The amount time spent by a port in the

learning and listening states waiting for a

BPDU that may return the port to the

blocking state.

Show 11 more labels / short text on this page
STP Operation Levels · Bridge Identifier(Not user · configurable · below) · Priority · the root bridge · 2 seconds · Maximum Age Timer · 20 seconds · Forward Delay Timer · 15 seconds
Page 40 of the Planet Technology WSD-800 user manual — 4.5.3 Port Band Restrict
Page 40 · click to enlarge
Page 40

The following are the user-configurable STP parameters for the port or port group level:

Variable Description Default Value

Port Priority A relative priority for each

port –lower numbers give a higher priority

and a greater chance of a given port being

elected as the root port

Port Cost A value used by STP to evaluate paths –

19-100Mbps Fast Ethernet ports

STP calculates path costs and selects the

4-1000Mbps Gigabit Ethernet ports

path with the minimum cost as the active

Enable state STP enabled for all ports

The Switch’s factory default setting should cover the majority of installations. However, it is advisable to keep the

default settings as set at the factory; unless, it is absolutely necessary. The user changeable parameters in the

Switch are as follows:

Priority – A Priority for the Switch can be set from 0 to 65535. 0 is equal to the highest Priority.

Hello Time – The Hello Time can be from 1 to 10 seconds. This is the interval between two transmissions of

BPDU packets sent by the Root Bridge to tell all other Switches that it is indeed the Root Bridge. If you set a Hello

Time for your Switch, and it is not the Root Bridge, the set Hello Time will be used if and when your Switch

becomes the Root Bridge.

Planet Technology WSD-800 — 4.5.3 Port Band Restrict diagram (page 40)
Fig. 57 · 4.5.3 Port Band Restrict

occur.

Max. Age – The Max Age can be from 6 to 40 seconds. At the end of the Max Age, if a BPDU has still not been

received from the Root Bridge, your Switch will start sending its own BPDU to all other Switches for permission to

become the Root Bridge. If it turns out that your Switch has the lowest Bridge Identifier, it will become the Root

Bridge.

Forward Delay Timer – The Forward Delay can be from 4 to 30 seconds. This is the time any port on the

Switch spends in the listening state while moving from the blocking state to the forwarding state.

Planet Technology WSD-800 — 4.5.3 Port Band Restrict diagram (page 40)
Fig. 58 · 4.5.3 Port Band Restrict

Max. Age _ 2 x (Forward Delay - 1 second)

Show 7 more labels / short text on this page
path · Default Spanning-Tree Configuration · Feature Default Value · Port priority 128 · Port cost 19 · Bridge Priority 32,768 · User-Changeable STA Parameters
Page 41 of the Planet Technology WSD-800 user manual — LAN 2 LAN 3
Page 41 · click to enlarge
Page 41
Planet Technology WSD-800 — 4.5.3 Port Band Restrict diagram (page 41)
Fig. 59 · 4.5.3 Port Band Restrict

Max. Age _ 2 x (Hello Time + 1 second)

Port Priority – A Port Priority can be from 0 to 255. The lower the number, the greater the probability the port will

be chosen as the Root Port.

Port Cost – A Port Cost can be set from 0 to 65535. The lower the number, the greater the probability the port will

be chosen to forward packets.

3. Illustration of STP

A simple illustration of three switches connected in a loop is depicted in Figure 5-7. In this example, you can

anticipate some major network problems if the STP assistance is not applied. If switch A broadcasts a packet to

switch B, switch B will broadcast it to switch C, and switch C will broadcast it to back to switch A ... and so on. The

broadcast packet will be passed indefinitely in a loop, potentially causing a network failure. In this example, STP

breaks the loop by blocking the connection between switch B and C. The decision to block a particular connection

is based on the STP calculation of the most current Bridge and Port settings. Now, if switch A broadcasts a packet

to switch C, then switch C will drop the packet at port 2 and the broadcast will end there. Setting-up STP using

values other than the defaults, can be complex. Therefore, you are advised to keep the default factory settings and

STP will automatically assign root bridges/ports and block loop connections. Influencing STP to choose a

particular switch as the root bridge using the Priority setting, or influencing STP to choose a particular port to block

using the Port Priority and Port Cost settings is, however, relatively straight forward.

LAN 1

A

Bridge ID = 15

Port 1 Port 2

B

Bridge ID = 30

Bridge ID = 20

Port 2 Port 3

Port 2 Port 3

Portcast = 19 Portcast = 19

LAN 2 LAN 3

Before Applying the STA Rules

In this example, only the default STP values are used.

Show 9 more labels / short text on this page
Portcast = 19 · Port 3 · Portcast = 4 · Portcast = 4 · Portcast = 4 · Portcast = 4 · Port 1 · Port 1 · Portcast = 19
Page 42 of the Planet Technology WSD-800 user manual — 1. Spanning Tree Configuration
Page 42 · click to enlarge
Page 42

LAN 1

A

Port 1 Port 2

Root Port Root Port

B

C Port 1

Port 2 Port 3

Port 2 Port 3

LAN 2 LAN 3

After Applying the STA Rules

The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a

high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 4) on switch A are

connected to one (optional) Gigabit port on both switch B and C. The redundant link between switch B and C is

deliberately chosen as a 100 Mbps Fast Ethernet link (default port cost = 19). Gigabit ports could be used, but the

port cost should be increased from the default to ensure that the link between switch B and switch C is the blocked

link. 4.6.2 Spanning Tree Configuration

The Spanning Tree Protocol (STP) operates on two levels: On the switch level, the settings are globally

implemented. On the port level, the settings are implemented on a. per user-defined Group of ports.

1. Spanning Tree Configuration

The “Rapid Spanning Tree Bridge Configure” table allows configuring the spanning tree parameters.

Rapid Spanning Tree StatusThe spanning tree function of the switch is default disabled. This field enables to

turn on the spanning tree on the switch.

Force Protocol Version0 for IEEE 802.1D Spanning Tree, 2 for IEEE 802.1W Rapid Spanning Tree
Max Age(6 - 40 sec) the default setting is 20
Hello Time(1 - 10sec) the default setting is 2
Forward Delay(4 -30 sec) the default setting is 15
Bridge Priority(0 - 61440) the default setting is 32768
Show 7 more labels / short text on this page
Port 3 · Root Bridge · Designated Port · Designated Port · Port 1 · Designated Bridge · Blocked
Page 43 of the Planet Technology WSD-800 user manual — 3. STP Port Configuration
Page 43 · click to enlarge
Page 43
Planet Technology WSD-800 — 4.6.2 Spanning Tree Configuration diagram (page 43)
Fig. 60 · 4.6.2 Spanning Tree Configuration

2. Bridge Information

The informations of the STP Root show in the Bridge Information table.

Planet Technology WSD-800 — 2. Bridge Information diagram (page 43)
Fig. 61 · 2. Bridge Information

3. STP Port Configuration

On the STP port configuration, the settings are implemented on a. per user-defined Group of ports.

Planet Technology WSD-800 — 3. STP Port Configuration diagram (page 43)
Fig. 62 · 3. STP Port Configuration

The following fields can be set for STP port configuration:

Edge Port: Defines if this port connected directly to a single workstation, or this port that is directly connected to a

LAN segment where a loop cannot be created. For example, this port is connected to a PC, Print-Server, IP

camera or any other network end-node device. Since end nodes cannot cause forwarding loops, they can pass

directly through to the spanning tree forwarding state.

There are two selections for this function:

。 True - This port connected directly to a end-node device or LAN segment where a loop cannot be

。 False – This port connected to one or more LAN segments – maybe a ethernet switch or HUB, that a

loop might be occured

P2P Status: Enables or disables the device to establish a point-to-point link, or specifies for the device to

automatically establish a point-to-point link. A P2P port is also capable of rapid transition. P2P ports may be used

to connect to other bridges. Under RSTP, all ports operating in full-duplex mode are considered to be P2P ports,

created

Page 44 of the Planet Technology WSD-800 user manual — 4.6.2 Spanning Tree Configuration
Page 44 · click to enlarge
Page 44

unless manually overridden through configuration.

The link type attached to this port could be selected as following:

。 Auto - The switch automatically determines if the interface is attached to a point-to-point link or to shared

。 True – A connection to exactly one other bridge.

。 False - A connection to two or more bridges.

Port Priority: Defines if this port is more or less likely to become the root port. The range is from 0 to 255, the

default setting is 128.The lower number has the highest priority.

Path Cost: Specifies the path cost of the port. The switch uses this parameter to help determine which port will

become a forwarding port. Lower numbers will be used as forwarding ports first. The range is from 0 to 65535. The

default values based on IEEE802.1D are: 10Mb/s = 50-600, 100Mb/s = 10-60, 1000Mb/s = 3-10

Port Mcheck set: If the port property is a rapid, because of received STP BPDU, then it change into STP

compatible mode, According to Mcheck setting, change property into RSTP mode.

Planet Technology WSD-800 — 4.6.2 Spanning Tree Configuration diagram (page 44)
Fig. 63 · 4.6.2 Spanning Tree Configuration

media

Page 45 of the Planet Technology WSD-800 user manual — 4.6.3 Link Aggregation
Page 45 · click to enlarge
Page 45

4.6.3 Link Aggregation

Link aggregation can be used to increase the bandwidth of a network connection or to ensure fault recovery. Link

aggregation lets you group up consecutive ports into a single dedicated connection between any two of the

Switches or other Layer 2 switches. However, before making any physical connections between devices, use the

Link Aggregation menu to specify the link aggregation on the devices at both ends. When using a port link

aggregation, note that:

。 The ports used in a link aggregation must all be of the same media type (RJ-45, 100 Mbps fiber).

。 The ports that can be assigned to the same link aggregation have certain other restrictions (see below).

。 Ports can only be assigned to one link aggregation.

。 The ports at both ends of a connection must be configured as link aggregation ports.

。 None of the ports in a link aggregation can be configured as a mirror source port or a mirror target port.

。 All of the ports in a link aggregation have to be treated as a whole when moved from/to, added or deleted

from a VLAN.

。 The Spanning Tree Protocol will treat all the ports in a link aggregation as a whole.

。 Enable the link aggregation prior to connecting any cable between the switches to avoid creating a data

loop.

。 Disconnect all link aggregation port cables or disable the link aggregation ports before removing a port link

aggregation to avoid creating a data loop.

It allows a maximum of four ports to be aggregated at the same time and up to 4 groups. If the group is defined as

a LACP static link aggregationing group, then any extra ports selected are placed in a standby mode for

redundancy if one of the other ports fails. If the group is defined as a local static link aggregationing group, then

the number of ports must be the same as the group member ports.

Planet Technology WSD-800 — 4.6.3 Link Aggregation diagram (page 45)
Fig. 64 · 4.6.3 Link Aggregation
Page 46 of the Planet Technology WSD-800 user manual — 4.7.1.1 Theory
Page 46 · click to enlarge
Page 46

4.7 Security

4.7.1 VLAN

4.7.1.1 Theory

Understanding IEEE 802.1p Priority

Priority tagging is a function defined by the IEEE 802.1p standard designed to provide a means of managing traffic

on a network where many different types of data may be transmitted simultaneously. It is intended to alleviate

problems associated with the delivery of time critical data over congested networks. The quality of applications

that are dependent on such time critical data, such as video conferencing, can be severely and adversely affected

by even very small delays in transmission.

Network devices that are in compliance with the IEEE 802.1p standard have the ability to recognize the priority

level of data packets. These devices can also assign a priority label or tag to packets. Compliant devices can also

strip priority tags from packets. This priority tag determines the packet's degree of expeditiousness and

determines the queue to which it will be assigned.

Priority tags are given values from 0 to 7 with 0 being assigned to the lowest priority data and 7 assigned to the

highest. The highest priority tag 7 is generally only used for data associated with video or audio applications,

which are sensitive to even slight delays, or for data from specified end users whose data transmissions warrant

special consideration.

The Switch allows you to further tailor how priority tagged data packets are handled on your network. Using

queues to manage priority tagged data allows you to specify its relative priority to suit the needs of your network.

There may be circumstances where it would be advantageous to group two or more differently tagged packets into

the same queue. Generally, however, it is recommended that the highest priority queue, Queue 1, be reserved for

data packets with a priority value of 7. Packets that have not been given any priority value are placed in Queue 0

and thus given the lowest priority for delivery.

A weighted round robin system is employed on the Switch to determine the rate at which the queues are emptied

of packets. The ratio used for clearing the queues is 4:1. This means that the highest priority queue, Queue 1, will

clear 4 packets for every 1 packet cleared from Queue 0.

Remember, the priority queue settings on the Switch are for all ports, and all devices connected to the Switch will

be affected. This priority queuing system will be especially beneficial if your network employs switches with the

capability of assigning priority tags.

A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than

the physical layout. VLAN can be used to combine any collection of LAN segments into an autonomous user

group that appears as a single LAN. VLAN also logically segment the network into different broadcast domains so

VLAN Description

Page 47 of the Planet Technology WSD-800 user manual — NOTICE:
Page 47 · click to enlarge
Page 47

that packets are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular

subnet, although not necessarily.

VLAN can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific

domains.

A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently

communicate with each other are assigned to the same VLAN, regardless of where they are physically on the

network. Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to

only members of the VLAN on which the broadcast was initiated.

Planet Technology WSD-800 — 4.7 Security diagram (page 47)
Fig. 65 · 4.7 Security

NOTICE:

1. No matter what basis is used to uniquely identify end nodes and assign these nodes VLAN

membership, packets cannot cross VLAN without a network device performing a routing function

between the VLAN.

2. The Switch supports Port-based VLAN and IEEE 802.1Q VLAN. The port untagging function can

be used to remove the 802.1 tag from packet headers to maintain compatibility with devices that

are tag-unaware.

3. The Switch's default is to assign all ports to a single 802.1Q VLAN named DEFAULT_VLAN. As

new VLAN is created, the member ports assigned to the new VLAN will be removed from the

DEFAULT_ VLAN port member list. The DEFAULT_VLAN has a VID = 1.

Port-based VLAN limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are

members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or

an entire department.

On port-based VLAN.NIC do not need to be able to identify 802.1Q tags in packet headers. NIC send and receive

normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using

normal Ethernet protocols. Even though this is always the case, when the destination for a packet lies on another

switch port, VLAN considerations come into play to decide if the packet is dropped by the Switch or delivered.

IEEE 802.1Q VLANs

IEEE 802.1Q (tagged) VLAN are implemented on the Switch. 802.1Q VLAN require tagging, which enables them

to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).

VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a

VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN,

and this includes broadcast, multicast and unicast packets from unknown sources.

VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between

stations that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging

feature of IEEE 802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet

Port-based VLAN

Page 48 of the Planet Technology WSD-800 user manual — 4.7 Security
Page 48 · click to enlarge
Page 48

headers. The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical

connection and allows Spanning Tree to be enabled on all ports and work normally.

Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allow

VLAN to work with legacy switches that don’t recognize VLAN tags in packet headers. The tagging feature allows

VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree

to be enabled on all ports and work normally.

Some relevant terms:

Tagging - The act of putting 802.1Q VLAN information into the header of a packet.

Untagging - The act of stripping 802.1Q VLAN information out of the packet header.

802.1Q VLAN Tags

The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC

address. Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field

is equal to 0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets

and consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring

packets so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user

priority are used by 802.1p. The VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID

is 12 bits long, 4094 unique VLAN can be identified.

The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information

originally contained in the packet is retained.

Page 49 of the Planet Technology WSD-800 user manual — 4.7 Security
Page 49 · click to enlarge
Page 49

802.1Q Tag

User Priority CFI VLAN ID (VID)

3 bits 1 bits 12 bits

TPID (Tag Protocol Identifier) TCI (Tag Control Information)

2 bytes 2 bytes

6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes

The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether

Type/Length or Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic

Redundancy Check (CRC) must be recalculated.

Adding an IEEE802.1Q Tag

Dest. Addr. Src. Addr. Length/E. type Data Old CRC

Dest. Addr. Src. Addr. E. type Tag Length/E. type Data New CRC

Priority CFI VLAN ID

Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant

network device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices

(and indeed, the entire network – if all network devices are 802.1Q compliant).

Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no

VLAN are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged

packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this

PVID, in so far as VLAN are concerned. Tagged packets are forwarded according to the VID contained within the

tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the

VID is.

Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will

compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID

are different the switch will drop the packet. Because of the existence of the PVID for untagged packets and the

VID for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.

A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to

store them.

Show 10 more labels / short text on this page
Preamble Destination · Source · VLAN TAG Ethernet · Data FCS · Address · Address · Type · Original Ethernet · New Tagged Packet · Port VLAN ID
Page 50 of the Planet Technology WSD-800 user manual — 4.7.1.2 VLAN Configuration
Page 50 · click to enlarge
Page 50

Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware

device before packets are transmitted – should the packet to be transmitted have a tag or not? If the transmitting

port is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to

a tag-aware device, the packet should be tagged.

The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on

the Switch to the "default". As new VLAN are configured in Port-based mode, their respective member ports are

removed from the "default."

VLAN and Trunk Groups

In order to use VLAN segmentation in conjunction with port trunk groups, you can first set the port trunk group(s),

and then you may configure VLAN settings. If you wish to change the port trunk grouping with VLAN already in

place, you will not need to reconfigure the VLAN settings after changing the port trunk group settings. VLAN

settings will automatically change in conjunction with the change of the port trunk group settings

4.7.1.2 VLAN Configuration

Packets can only be broadcast among other members of the same VLAN group. Note all unselected ports are

treated as belonging to the default system VLAN. If port-based VLAN are enabled, then VLAN-tagging is ignored.

1. On VLAN Configuration table, choose Port-based VLAN . Click on the “OK” button.
Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 50)
Fig. 66 · 4.7.1.2 VLAN Configuration
2. The main page then change to Port-base VLAN table, click on the “Add/Modify” button to create a new VLAN

group.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 50)
Fig. 67 · 4.7.1.2 VLAN Configuration
3. The Port-base VLAN Confirutation table then pops up, enter the VLAN group ID, VLAN name and select the

member ports for the VLAN.

4. Click the “OK” button to add the VLAN.
5. Select the ports in the Port List field and click on the Add button to add the member ports to the VLAN. The

selected VLAN member then shows in the VLAN Member field.

Default VLANs · Port-based VLAN Configuration

Page 51 of the Planet Technology WSD-800 user manual — Understand nomenclature of the Switch
Page 51 · click to enlarge
Page 51
Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 51)
Fig. 68 · 4.7.1.2 VLAN Configuration
6. Click on the “Close” button and back to the Port-based VLAN main page.

The “Show VLAN Member” button is to list the valid VLANs. You can also remove the added VALN by click on

this button.

802.1Q VLAN Configuration

There are up to 256 configurable VLAN groups. By default when 802.1Q is enabled, all ports on the switch belong

to default VLAN (VID 1). The default VLAN cannot be deleted.

Understand nomenclature of the Switch

Every port on an 802.1Q compliant switch can be configured as tagging or untagging.

。 Tagging: Ports with tagging enabled will put the VID number, priority and other VLAN information into the

header of all packets that flow into those ports. If a packet has previously been tagged, the port will not alter

the packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by

other 802.1Q compliant devices on the network to make packet-forwarding decisions.

。 Untagging: Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into those ports.

If the packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received

by and forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is

Tagging and Untagging

Page 52 of the Planet Technology WSD-800 user manual — 4.7.1.2 VLAN Configuration
Page 52 · click to enlarge
Page 52

only used internally within the Switch). Untagging is used to send packets from an 802.1Q-compliant

network device to a non-compliant network device.

Income Frame is tagged Income Frame is untagged

Leave port is tagged Frame remains tagged Tag is inserted

Leave port is untagged Tag is removed Frame remain untagged

Here pay attention to the explainion of “Access”, ”Always Untag”and “Trunk”.

。 Access: Ports will strip the 802.1Q tag from all packets that out of those ports. If the packet doesn’t have an

802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and forwarded by an

untagging port will have no 802.1Q VLAN information. Untagging is used to send packets from an

802.1Q-compliant network device to a non-compliant network device.

Ports with “Access” mode belong to a single untagged VLAN.

。 Trunk: Ports with tagging enabled will put the VID number, priority and other VLAN information into the

header of all packets that out of those ports. If a packet has previously been tagged, the port will not alter the

packet, thus keeping the VLAN information intact. The VLAN information in the tag can then be used by

other 802.1Q compliant devices on the network to make packet forwarding decisions.

。 Always Untag: The port belongs to VLANs, and each VLAN is user-defined as tagged or untagged (full

802.1Q mode). Ports will strip the 802.1Q tag from all packets that out of those ports.

Port Mode VLAN Membership Frame Leave

Access Belongs to a single untagged VLAN

( Tag=PVID be removed)

Allowed to belongs to multiple untagged

VLANs at the same time

Allowed to belongs to multiple Tagged

VLANs at the same time

(Tag=PVID or Original VID be remained)

Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for

accommodating devices that you want to participate in the VLAN but that don’t support tagging. The Switch allows

each port to set one PVID, the range is 1~255, default PVID is 1. The PVID must be the same as the VLAN ID that

the port was defined as belonging to in the VLAN group, or the untagged traffic will be dropped.

1. Select 802.1Q VLAN in the VLAN Type field and click on the “OK” button.
Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 52)
Fig. 69 · 4.7.1.2 VLAN Configuration
Show 10 more labels / short text on this page
Frame Income · Frame Leave · 。 · Untagged · Untagged · Always Untag · (Tag=PVID be removed) · Tagged · Trunk · Port VID (PVID)
Page 53 of the Planet Technology WSD-800 user manual — 4.7.1.2 VLAN Configuration
Page 53 · click to enlarge
Page 53

The main page then changes to the 802.1Q VLAN table which displays the VLAN configuration of each port.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 53)
Fig. 70 · 4.7.1.2 VLAN Configuration
2. If you want to configure port #2 to be in a VLAN other than default VLAN. Double click on “port2” to enter into

VLAN port configuration window.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 53)
Fig. 71 · 4.7.1.2 VLAN Configuration
3. Choose the Link Type in the drop drop down menu: Acces s , Always Untag or Trunk .

other hand, if the Trunk type is chosen, it will put the VID number, priority and other VLAN information into the

header of all packets that out of this port. And if the Always Untag type is chosen, it will strip the 802.1Q tag

from all packets that out of the port. But the port can be assigned to more than one VLAN group.

4. Define the PVID for the port

Set the port VLAN ID that will be assigned to untagged traffic on a given port. This feature is useful for

accommodating devices that you want to participate in the VLAN but that don’t support tagging.

Page 54 of the Planet Technology WSD-800 user manual — 4.7.1.2 VLAN Configuration
Page 54 · click to enlarge
Page 54
Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 54)
Fig. 72 · 4.7.1.2 VLAN Configuration
5. Trunk configuration: If the Trunk type is chosen, please follow the steps to set the Trunk of the port.

5.1 Add and define the names and VIDs for new VLANs. The VID number ranges from 2 to 4094. Fill the VID field

and the VLAN Name field in the Set VLAN’s VID & Name table and click on the “Add/Modify” button to save.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 54)
Fig. 73 · 4.7.1.2 VLAN Configuration

5.2 The added new VLAN then shows the the VLAN Table field in the Set Trunk Port for VLAN table.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 54)
Fig. 74 · 4.7.1.2 VLAN Configuration

5.3 Select on the VLAN chich you want to tag with in the VLAN Table field and click on the “Add” button to add.

This will add the VLAN in to the VLAN with The Trunk Port field.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 54)
Fig. 75 · 4.7.1.2 VLAN Configuration

5.4 Click on the “close” button to close the VLAN port configuration table of port #2, and back to the 802.1Q main

page.

5.5 Click on the “Show VLAN Members” button to show the VLAN members.

Planet Technology WSD-800 — 4.7.1.2 VLAN Configuration diagram (page 54)
Fig. 76 · 4.7.1.2 VLAN Configuration

5.6 As shows in the following screen:

Page 55 of the Planet Technology WSD-800 user manual — 4.7.2 MAC Address Bind
Page 55 · click to enlarge
Page 55
Planet Technology WSD-800 — 4.7.2 MAC Address Bind diagram (page 55)
Fig. 77 · 4.7.2 MAC Address Bind

4.7.2 MAC Address Bind

This function is based upon for the Switch security. When you add one MAC Address is bind with one port. It

remains in the Switch's address table, regardless of whether the device is physically connected to the Switch. This

saves the Switch from having to re-learn a device's MAC address after it has been disconnected or powered-off

from the network, and then reconnected at some time later. If the Network station is connected with one port want

to control the Switch, the station’s MAC Address must be the same as one MAC Address

To bind the MAC Address, click on the Security/MAC Address Binding menu button, the main web page then

shows the MAC Address Bind function table.

1. Fill the MAC Address field with MAC address in the format “xx-xx-xx-xx-xx-xx “ and choose the port to bind

the MAC Address in the Port field.

2. Click on the “Add” button.
3. To remove the MAC Address binded by the port. Simply click on the “Delete” button of the MAC Address in the

Show MAC Address Table.

Planet Technology WSD-800 — 4.7.2 MAC Address Bind diagram (page 55)
Fig. 78 · 4.7.2 MAC Address Bind
Page 56 of the Planet Technology WSD-800 user manual — 4.7.3 MAC Address Filtering
Page 56 · click to enlarge
Page 56
Planet Technology WSD-800 — 4.7.3 MAC Address Filtering diagram (page 56)
Fig. 79 · 4.7.3 MAC Address Filtering

4.7.3 MAC Address Filtering

MAC address filtering allows the Switch to drop unwanted traffic. Traffic is filtered based on the destination

addresses.

To filter the MAC Address, click on the Security/MAC Address Filtering menu button, the main web page then

shows the MAC Address Filtering function table.

1. Fill the MAC Address field with MAC address in the format “xx-xx-xx-xx-xx-xx “ .
2. Click on the “Add” button to add.
3. To remove the MAC Address filtered by the port. Simply click on the “Delete” button of the MAC Address in the

Current Filtering MAC Table.

Planet Technology WSD-800 — 4.7.3 MAC Address Filtering diagram (page 56)
Fig. 80 · 4.7.3 MAC Address Filtering
Page 57 of the Planet Technology WSD-800 user manual — 4.7.5 MAC Address Aging Time
Page 57 · click to enlarge
Page 57
Planet Technology WSD-800 — 4.7.4 MAC Address Learning diagram (page 57)
Fig. 81 · 4.7.4 MAC Address Learning

4.7.4 MAC Address Learning

The Switch is able to disable MAC Address learning function on ports.

1. Fill the Port Lis t field in the MAC Address Learning table and select Enable/Disable in the MAC Address

Learning field.

2. Click on the “OK” button to save.
Planet Technology WSD-800 — 4.7.4 MAC Address Learning diagram (page 57)
Fig. 82 · 4.7.4 MAC Address Learning

4.7.5 MAC Address Aging Time

The Aging Time affects the learning process of the Switch. Dynamic forwarding table entries, which are made up

of the source and destination MAC addresses and their associated port numbers, are deleted from the table if they

are not accessed within the aging time.

The aging time can be from 30 to 1,000,000 seconds with a default value of 300 seconds. A very long aging time

can result in dynamic forwarding table entries that are out-of-date or no longer exist. This may cause incorrect

packet forward indecisions by the Switch.

If the Aging Time is too short however, many entries may be aged out too soon. This will result in a high

Page 58 of the Planet Technology WSD-800 user manual — 4.7.6.1 Theory
Page 58 · click to enlarge
Page 58

percentage of received packets whose source addresses cannot be found in the forwarding table, in which case

the Switch will broadcast the packet to all ports, negating many of the benefits of having a Switch.

Static forwarding entries are not affected by the aging time.

To set the Aging Time, enter the number in the MAC Address Aging Time field, and click on the “OK” button to

save. The valid range is 30~1000 seconds. Default is 300 seconds.

Planet Technology WSD-800 — 4.7.6.1 Theory diagram (page 58)
Fig. 83 · 4.7.6.1 Theory

4.7.6 802.1X Port-Based Network Access Control

4.7.6.1 Theory

Understanding IEEE 802.1X Port-Based Authentication

The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts

unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server

authenticates each client connected to a switch port before making available any services offered by the Switch or

the LAN.

Until the client is authenticated, 802.1X access control allows only Extensible Authentication Protocol over LAN

(EAPOL) traffic through the port to which the client is connected. After authentication is successful, normal traffic

can pass through the port.

This section includes this conceptual information:

  • Device Roles
  • Authentication Initiation and Message Exchange
  • Ports in Authorized and Unauthorized States
Page 59 of the Planet Technology WSD-800 user manual — 4.7.6.1 Theory
Page 59 · click to enlarge
Page 59

With 802.1X port-based authentication, the devices in the network have specific roles as shown below.

Planet Technology WSD-800 — 4.7.6.1 Theory diagram (page 59)
Fig. 84 · 4.7.6.1 Theory

z Client—the device (workstation) that requests access to the LAN and switch services and responds to

requests from the Switch. The workstation must be running 802.1X-compliant client software such as that

offered in the Microsoft Windows XP operating system. (The client is the supplicant in the IEEE 802.1X

specification.)

z Authentication server—performs the actual authentication of the client. The authentication server

validates the identity of the client and notifies the Switch whether or not the client is authorized to access

the LAN and switch services. Because the Switch acts as the proxy, the authentication service is

transparent to the client. In this release, the Remote Authentication Dial-In User Service (RADIUS)

security system with Extensible Authentication Protocol (EAP) extensions is the only supported

authentication server; it is available in Cisco Secure Access Control Server version 3.0. RADIUS operates

in a client/server model in which secure authentication information is exchanged between the RADIUS

server and one or more RADIUS clients.

z Switch (802.1X device)—controls the physical access to the network based on the authentication status

of the client. The Switch acts as an intermediary (proxy) between the client and the authentication server,

requesting identity information from the client, verifying that information with the authentication server, and

relaying a response to the client. The Switch includes the RADIUS client, which is responsible for

encapsulating and decapsulating the Extensible Authentication Protocol (EAP) frames and interacting

with the authentication server. When the Switch receives EAPOL frames and relays them to the

authentication server, the Ethernet header is stripped and the remaining EAP frame is re-encapsulated in

the RADIUS format. The EAP frames are not modified or examined during encapsulation, and the

authentication server must support EAP within the native frame format. When the Switch receives frames

from the authentication server, the server's frame header is removed, leaving the EAP frame, which is

then encapsulated for Ethernet and sent to the client.

„ Device Roles

Page 60 of the Planet Technology WSD-800 user manual — NOTICE:
Page 60 · click to enlarge
Page 60

„ Authentication Initiation and Message Exchange

The Switch or the client can initiate authentication. If you enable authentication on a port by using the dot1x

port-control auto interface configuration command, the Switch must initiate authentication when it determines

that the port link state transitions from down to up. It then sends an EAP-request/identity frame to the client to

request its identity (typically, the Switch sends an initial identity/request frame followed by one or more requests

for authentication information). Upon receipt of the frame, the client responds with an EAP-response/identity

frame.

However, if during bootup, the client does not receive an EAP-request/identity frame from the switch, the client

can initiate authentication by sending an EAPOL-start frame, which prompts the switch to request the client's

Planet Technology WSD-800 — 4.7.6.1 Theory diagram (page 60)
Fig. 85 · 4.7.6.1 Theory

NOTICE:

If 802.1X is not enabled or supported on the network access device, any EAPOL frames from the client are

dropped. If the client does not receive an EAP-request/identity frame after three attempts to start

authentication, the client transmits frames as if the port is in the authorized state. A port in the authorized

state effectively means that the client has been successfully authenticated.

When the client supplies its identity, the Switch begins its role as the intermediary, passing EAP frames between

the client and the authentication server until authentication succeeds or fails. If the authentication succeeds, the

Switch port becomes authorized. For more information, see the "Ports in Authorized and Unauthorized States"

The specific exchange of EAP frames depends on the authentication method being used. “Figure 2-43” shows a

message exchange initiated by the client using the One-Time-Password (OTP) authentication method with a

RADIUS server.

identity · section

Page 61 of the Planet Technology WSD-800 user manual — 4.7.6.1 Theory
Page 61 · click to enlarge
Page 61
Planet Technology WSD-800 — 4.7.6.1 Theory diagram (page 61)
Fig. 86 · 4.7.6.1 Theory

„ Ports in Authorized and Unauthorized States

The Switch port state determines whether or not the client is granted access to the network. The port starts in the

unauthorized state. While in this state, the port disallows all ingress and egress traffic except for 802.1X protocol

packets. When a client is successfully authenticated, the port transitions to the authorized state, allowing all traffic

for the client to flow normally.

If a client that does not support 802.1X is connected to an unauthorized 802.1X port, the Switch requests the

client's identity. In this situation, the client does not respond to the request, the port remains in the unauthorized

state, and the client is not granted access to the network.

In contrast, when an 802.1X-enabled client connects to a port that is not running the 802.1X protocol, the client

initiates the authentication process by sending the EAPOL-start frame. When no response is received, the client

sends the request for a fixed number of times. Because no response is received, the client begins sending frames

as if the port is in the authorized state

If the client is successfully authenticated (receives an Accept frame from the authentication server), the port state

changes to authorized, and all frames from the authenticated client are allowed through the port. If the

authentication fails, the port remains in the unauthorized state, but authentication can be retried. If the

authentication server cannot be reached, the switch can retransmit the request. If no response is received from

the server after the specified number of attempts, authentication fails, and network access is not granted.

When a client logs off, it sends an EAPOL-logoff message, causing the switch port to transition to the

unauthorized state.

Page 62 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 62 · click to enlarge
Page 62

If the link state of a port transitions from up to down, or if an EAPOL-logoff frame is received, the port returns to the

unauthorized state.

4.7.6.2 802.1X Configuration

This Switch has two 802.1X Mode: Radius Server & Local Authenticate choose one you need

  • Local Authenticate — In this situation, do not need Radius server in the network, all authentication completed

by 802.1x Switch,the normal topologies as below

Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 62)
Fig. 87 · 4.7.6.2 802.1X Configuration
1. Enter “ 802.1X Port Status Configuration " , there are 3“Authenticate authorization” states
Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 62)
Fig. 88 · 4.7.6.2 802.1X Configuration
Page 63 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 63 · click to enlarge
Page 63

。 Auto: enables 802.1X authentication and causes the port to begin in the unauthorized state, allowing only

EAPOL frames to be sent and received through the port. It’s a default status

。 Force authorizeddisables 802.1X authentication and causes the port to transition to the authorized state

without any authentication exchange required. The port transmits and receives normal traffic without

802.1X-based authentication of the client. This is the default setting.

。 Force unauthorized: causes the port to remain in the unauthorized state, ignoring all attempts by the client

to authenticate. The switch cannot provide authentication services to the client through the interface.

。 Maximum account numberthe biggest user's quantity of passing authentication under this port, set 1 ,

Only one user can pass this authentication,The second user is unable to carry on authentication on this

port。The max value is 32

。 Current account number: show the current user who passed authentication under one port.

2. Enter”802.1X Local Authenticate” to set legitimate user information: In the local server model, the need

for each port through the establishment of the legitimate user authentication information available. As

Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 63)
Fig. 89 · 4.7.6.2 802.1X Configuration
3. “Other configuration”: only choose “Local Authenticate” mode is available. If you not have good

experiences please keep the default value.

Figure2-45

Page 64 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 64 · click to enlarge
Page 64
Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 64)
Fig. 90 · 4.7.6.2 802.1X Configuration
  • Radius Server — In this situation, need a Radius server in the network, the normal topologies as below
1. Select the “ Radius Server ” mode.
2. The RADIUS Server configuration table includes the following fields:
Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 64)
Fig. 91 · 4.7.6.2 802.1X Configuration
Page 65 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 65 · click to enlarge
Page 65

The IP address of the RADIUS server being added.

  • RADIUS Server IP

The UDP port used by this server. The valid range is 0 - 65535.

  • Authentication

The default UDP Port No. is 1812

The UDP port used by accounting server. The valid range is 0 -

  • Account

The default UDP Port No. is 1813

  • Share Key Indicates if the shared secret for this server has been

configured.

3. Setup the RADIUS server and assign the client IP address to the Web-Smart switch. In this case, field in

the default IP Address of the Web-Smart switch with 192.168.0.100. And also make sure the shared secret

key is as same as the one you had set at the switch RADIUS server – 12345678 at this case.

Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 65)
Fig. 92 · 4.7.6.2 802.1X Configuration

Address · Port(1-65535) · Port(1-65535)

Page 66 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 66 · click to enlarge
Page 66
4. Configure ports attribute of 802.1X, the same as “802.1X Port Status Configuration”.
Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 66)
Fig. 93 · 4.7.6.2 802.1X Configuration

server or the port is a uplink port that is connected to another switch. Or once the 802.1X stat

to work, the switch might not be able to access the RADIUS server.

5. Create user data. That step is different of “Local Authenticate”, the establishment of the user data needs to

be created on the Radius Server PC. For example, the Radius Server founded on Win2000 Server, and

then:

Page 67 of the Planet Technology WSD-800 user manual — 4.7.6.2 802.1X Configuration
Page 67 · click to enlarge
Page 67
Planet Technology WSD-800 — 4.7.6.2 802.1X Configuration diagram (page 67)
Fig. 94 · 4.7.6.2 802.1X Configuration

Enter ” Active Directory Users and Computers”, create legal user data, the next,

right-click a user what you created to enter properties, and what to be noticed:

Page 68 of the Planet Technology WSD-800 user manual — 4.7.6.3 802.1X Client Configuration
Page 68 · click to enlarge
Page 68
Planet Technology WSD-800 — 4.7.6.3 802.1X Client Configuration diagram (page 68)
Fig. 95 · 4.7.6.3 802.1X Client Configuration
6. The last, run your 802.1X Client

4.7.6.3 802.1X Client Configuration

Windows XP is originally 802.1X support. As to other operating systems (windows 98SE, ME, 2000), an 802.1X

client utility is needed. The following procedures show how to configure 802.1X Authentication in Windows XP.

Please note that if you want to change the 802.1x authentication type of a wireless client, i.e. switch to EAP-TLS

from EAP-MD5, you must remove the current existing wireless network from your preferred connection first, and

add it in again.

  • Configure Sample: EAP-MD5 Authentication
1. Go to Start > Control Panel, double-click on “ Network Connections ”.
2. Right-click on the Local Network Connection.
3. Click “ Properties ” to open up the Properties setting window.
Page 69 of the Planet Technology WSD-800 user manual — 4.7.6.3 802.1X Client Configuration
Page 69 · click to enlarge
Page 69
Planet Technology WSD-800 — 4.7.6.3 802.1X Client Configuration diagram (page 69)
Fig. 96 · 4.7.6.3 802.1X Client Configuration
4. Select “ Authentication ” tab.
5. Select “ Enable network access control using IEEE 802.1X ” to enable 802.1x authentication.
Planet Technology WSD-800 — 4.7.6.3 802.1X Client Configuration diagram (page 69)
Fig. 97 · 4.7.6.3 802.1X Client Configuration
6. Select “ MD-5 Challenge ” from the drop-down list box for EAP type.
7. Click “ OK ”.
8. When wireless client has associated with WSD-800 / WGSD-910, a user authentication notice appears in

system tray. Click on the notice to continue.

Page 70 of the Planet Technology WSD-800 user manual — 4.7.6.3 802.1X Client Configuration
Page 70 · click to enlarge
Page 70
Planet Technology WSD-800 — 4.7.6.3 802.1X Client Configuration diagram (page 70)
Fig. 98 · 4.7.6.3 802.1X Client Configuration
9. Enter the user name, password and the logon domain that your account belongs.
10. Click “ OK ” to complete the validation process.
Planet Technology WSD-800 — 4.7.6.3 802.1X Client Configuration diagram (page 70)
Fig. 99 · 4.7.6.3 802.1X Client Configuration
Page 71 of the Planet Technology WSD-800 user manual — QoS Terminology
Page 71 · click to enlarge
Page 71

4.8 QoS

4.8.1 Understand QOS

Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over

network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as

multi-media, video, protocol-specific, time critical, and file-backup traffic.

QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your

data and allows you to prioritize certain applications across your network. You can define exactly how you want the

switch to treat selected applications and types of traffic.

You can use QoS on your system to:

。 Control a wide variety of network traffic by:

。 Classifying traffic based on packet attributes.

。 Assigning priorities to traffic (for example, to set higher priorities to time-critical or business-critical

applications).

。 Applying security policy through traffic filtering.

。 Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by

minimizing delay and jitter.

。 Improve performance for specific types of traffic and preserve performance as the amount of traffic grows.

。 Reduce the need to constantly add bandwidth to the network.

。 Manage network congestion.

QoS Terminology

Classifier-classifies the traffic on the network. Traffic classifications are determined by protocol, application,

source, destination, and so on. You can create and modify classifications. The Switch then groups classified traffic

in order to schedule them with the appropriate service level.

DiffServ Code Point (DSCP) - is the traffic prioritization bits within an IP header that are encoded by certain

applications and/or devices to indicate the level of service required by the packet across a network.

Service Level-defines the priority that will be given to a set of classified traffic. You can create and modify

service levels.

Policy-comprises a set of “rules” that are applied to a network so that a network meets the needs of the business.

That is, traffic can be prioritized across a network according to its importance to that particular business type.

QoS Profile-consists of multiple sets of rules (classifier plus service level combinations). The QoS profile is

assigned to a port(s).

Rules-comprises a service level and a classifier to define how theSwitch will treat certain types of traffic. Rules

are associated with a QoS Profile (see above).

To implement QoS on your network, you need to carry out the following actions:

1. Define a service level to determine the priority that will be applied to traffic.
Page 72 of the Planet Technology WSD-800 user manual — 1. MAC-COS Mapping
Page 72 · click to enlarge
Page 72
2. Apply a classifier to determine how the incoming traffic will be classified and thus treated by the Switch.
3. Create a QoS profile which associates a service level and a classifier.
4. Apply a QoS profile to a port(s).

4.8.2 QOS Configuration

QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected

by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In

802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.

The Switch supports four kinds of Traffic classifiers: 802.1P/ Port/MAC/VLANs and four queues.

Planet Technology WSD-800 — 4.8.2 QOS Configuration diagram (page 72)
Fig. 100 · 4.8.2 QOS Configuration

high class. Zero is the less class. The user may configure the mapping between COS and Traffic classifiers.

1. MAC-COS Mapping

QoS settings allow customization of MAC address to Traffic classifiers.

1. Fill the MAC Address field in the MAC-CoS Mapping Configuration Table in the In the format

“xx-xx-xx-xx-xx-xx “.

2. Fill the mapping number in the CoS (0-7) field.
3. Click on the “OK” button to save.
4. To remove the MAC-CoS mapping item, simply click on the “Delete” button in the Show MAC-CoS Mapping

table.

Planet Technology WSD-800 — 1. MAC-COS Mapping diagram (page 72)
Fig. 101 · 1. MAC-COS Mapping
Page 73 of the Planet Technology WSD-800 user manual — 2. VLAN-COS Mapping
Page 73 · click to enlarge
Page 73
Planet Technology WSD-800 — 4.8.2 QOS Configuration diagram (page 73)
Fig. 102 · 4.8.2 QOS Configuration

2. VLAN-COS Mapping

QoS settings allow customization of VLAN ID to Traffic classifiers

1. Fill the VID (1-2094) field in the VLAN-CoS Mapping Table.
2. Fill the mapping number in the CoS (0-7) field.
3. Click on the “OK” button to save.
4. To remove the VLAN-CoS mapping item, simply click on the “Delete” button in the Show VLAN-CoS

Mapping table.

Planet Technology WSD-800 — 2. VLAN-COS Mapping diagram (page 73)
Fig. 103 · 2. VLAN-COS Mapping
Page 74 of the Planet Technology WSD-800 user manual — 3. 802.1p-CoS Mapping
Page 74 · click to enlarge
Page 74
Planet Technology WSD-800 — 4.8.2 QOS Configuration diagram (page 74)
Fig. 104 · 4.8.2 QOS Configuration

3. 802.1p-CoS Mapping

QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected

by latency problems. The IEEE 802.1p Priority specification uses 8 priority levels to classify data packets. In

802.1p compliant devices, a tag inserted into the packet header is used to identify the priority level of data packets.

1. Fill the 802.1p Priority (0-7) field in the 802.1p-priority-CoS Mapping Configuration Table.
2. Fill the mapping number in the CoS (0-7) field.
3. Click on the “OK” button to save.
Planet Technology WSD-800 — 3. 802.1p-CoS Mapping diagram (page 74)
Fig. 105 · 3. 802.1p-CoS Mapping
Page 75 of the Planet Technology WSD-800 user manual — 5. COS-Queue Mapping
Page 75 · click to enlarge
Page 75
Planet Technology WSD-800 — 4.8.2 QOS Configuration diagram (page 75)
Fig. 106 · 4.8.2 QOS Configuration

4. Port-COS Mapping

QoS settings allow customization of VLAN ID to Traffic classifiers

1. Fill the Port List (e.g. 1-3,7) field in the port-based QoS Configuration Table.
2. Fill the mapping number in the CoS (0-7) field.
3. Click on the “OK” button to save.
Planet Technology WSD-800 — 4. Port-COS Mapping diagram (page 75)
Fig. 107 · 4. Port-COS Mapping

5. COS-Queue Mapping

1. Fill the CoS (0-7) field in the CoS-Queue Mapping Configuration Table.
2. Fill the mapping number in the Queue (0-3) field.
3. Click on the “OK” button to save.
Page 76 of the Planet Technology WSD-800 user manual — 6. Queue Management
Page 76 · click to enlarge
Page 76
Planet Technology WSD-800 — 4.8.2 QOS Configuration diagram (page 76)
Fig. 108 · 4.8.2 QOS Configuration

6. Queue Management

There are two rules for the Priority Queue: Weighted Round Robin (WRR) and Always Hight.

To configure Queue Rule, select the Queue Policy drop down menu in the Queue Rule Configuration table. And

Click on the “OK” button to save.

Planet Technology WSD-800 — 6. Queue Management diagram (page 76)
Fig. 109 · 6. Queue Management

If the WRR was chosen as the Queue Policy, the page would show in the main page.

Planet Technology WSD-800 — 6. Queue Management diagram (page 76)
Fig. 110 · 6. Queue Management
Page 77 of the Planet Technology WSD-800 user manual — IGMP Versions 1 and 2
Page 77 · click to enlarge
Page 77

4.9 Multicast

4.9.1 IGMP Snooping

Theory

Computers and network devices that want to receive multicast transmissions need to inform nearby routers that

they will become members of a multicast group. The Internet Group Management Protocol (IGMP) is used to

communicate this information. IGMP is also used to periodically check the multicast group for members that are no

longer active. In the case where there is more than one multicast router on a sub network, one router is elected as

the ‘queried’. This router then keeps track of the membership of the multicast groups that have active members.

The information received from IGMP is then used to determine if multicast packets should be forwarded to a given

sub network or not. The router can check, using IGMP, to see if there is at least one member of a multicast group

on a given subnet work. If there are no members on a sub network, packets will not be forwarded to that sub

network.

IGMP Versions 1 and 2

Multicast groups allow members to join or leave at any time. IGMP provides the method for members and

multicast routers to communicate when joining or leaving a multicast group.

IGMP version 1 is defined in RFC 1112. It has a fixed packet size and no optional data.

The format of an IGMP packet is shown below:

0 8 16 31

Type Response Time Checksum

Group Address (all zeros if this is a query)

The IGMP Type codes are shown below:

0x11 Membership Query (if Group Address is 0.0.0.0)

0x11 Specific Group Membership Query (if Group Address is Present)

0x16 Membership Report (version 2)

0x17 Leave a Group (version 2)

0x12 Membership Report (version 1)

IGMP packets enable multicast routers to keep track of the membership of multicast groups, on their respective

sub networks. The following outlines what is communicated between a multicast router and a multicast group

member using IGMP.

A host sends an IGMP “report” to join a group

IGMP Message Format · Octets · Type Meaning

Page 78 of the Planet Technology WSD-800 user manual — 4.9.2 IGMP Snooping Configuration
Page 78 · click to enlarge
Page 78

A host will never send a report when it wants to leave a group (for version 1).

A host will send a “leave” report when it wants to leave a group (for version 2).

Multicast routers send IGMP queries (to the all-hosts group address: 224.0.0.1) periodically to see whether any

group members exist on their sub networks. If there is no response from a particular group, the router assumes

that there are no group members on the network.

The Time-to-Live (TTL) field of query messages is set to 1 so that the queries will not be forwarded to other sub

networks.

IGMP version 2 introduces some enhancements such as a method to elect a multicast queried for each LAN, an

explicit leave message, and query messages that are specific to a given group.

The states a computer will go through to join or to leave a multicast group are shown below:

Leave Group Leave Group (Stop Timer) Join Group (Send Report,

Delaying Member Idle Member

4.9.2 IGMP Snooping Configuration

The default status of the IGMP Snooping function is disabled. To turn on the IGMP Snooping, select “Enable” of

the IGMP Snooping Status field and click on the “OK” button to save.

The following fields can be set for IGMP Port Policy configuration:

„ Immediate-LeaveIndicates the port , which will be limited for the accepted IGMP groups
„ Forwarding all leave pktUse to limit the number of IGMP groups that an interface can accept. The

possible value as following:

Show 9 more labels / short text on this page
Non-Member · Start Timer) · Query Received · (Start Timer) · Report Received · (Stop Timer) · Timer Expried · (Send report) · IGMP State Transitions
Page 79 of the Planet Technology WSD-800 user manual — 4.9.3 IGMP Port Policy
Page 79 · click to enlarge
Page 79
Planet Technology WSD-800 — 4.9.3 IGMP Port Policy diagram (page 79)
Fig. 111 · 4.9.3 IGMP Port Policy

4.9.3 IGMP Port Policy

For the security and management issue, the Switch is allowed to limiti the number of multicast groups by a specific

port. With system default setting, all the learned Multicast groups are accepted and forwarded. Atter the IGMP Port

Policy be configured on a specific port, the Switch will restrict the number of IGMP groups according to the

parameter. As the below drawing shows:

Planet Technology WSD-800 — 4.9.3 IGMP Port Policy diagram (page 79)
Fig. 112 · 4.9.3 IGMP Port Policy

The following fields can be set for IGMP Port Policy configuration:

„ PortIndicates the port , which will be limited for the accepted IGMP groups

„ Group Number: Use to limit the number of IGMP groups that an interface can accept. The possible value

as following:

  • Disable - No limit on the number of IGMP groups. ( Defatul Value)
  • 0-100 – 0: No IGMP grpups allowed; 1-100: The number of accepted IGMP groups on the

specific port.

Page 80 of the Planet Technology WSD-800 user manual — 4.9.3 IGMP Port Policy
Page 80 · click to enlarge
Page 80
Planet Technology WSD-800 — 4.9.3 IGMP Port Policy diagram (page 80)
Fig. 113 · 4.9.3 IGMP Port Policy

Configure Sample:

1. Select the Port field in the Set IGMP Port Policy Table, in this case, Port-2 be selected.
2. Fill the accepted number in the Group Number field. ( For this case, 4 multicast groups are allowed)
3. Click on the “OK” button to save.
Planet Technology WSD-800 — 4.9.3 IGMP Port Policy diagram (page 80)
Fig. 114 · 4.9.3 IGMP Port Policy
4. The worksatation that connect to Port-2 start to send IGMP Join/Report packets.
5. Select “IGMP Snooping Configuration” page to show the Multicast Group Table.
Page 81 of the Planet Technology WSD-800 user manual — 4.9.4 IGMP Group Policy
Page 81 · click to enlarge
Page 81
Planet Technology WSD-800 — 4.9.4 IGMP Group Policy diagram (page 81)
Fig. 115 · 4.9.4 IGMP Group Policy

The maximum number of IGMP multicast groups are restricting to 4 entries; the more IGMP Join packets will be

filtered.

4.9.4 IGMP Group Policy

The IGMP Group Policy allowed the networl administrator to assigning a specificy Multicast Group to a port. The

port is configured to send and receive all traffic for a particular mulcast group. Usually, the function is use to test

the multicast protocols in the network or for the PC/Laptop manufactory to pre-install operation system via

multicast. There is maximum 24 static Multicast Groups are able to assign.

Planet Technology WSD-800 — 4.9.4 IGMP Group Policy diagram (page 81)
Fig. 116 · 4.9.4 IGMP Group Policy

The following fields can be set for IGMP Group Policy configuration:

Set IGMP Group Policy

„ IndexAssign a No. 1~24 for the Multicast Group as a index for easy managment
„ Multicast GroupIdentifies the Multicast group IP address

(The valued range is from 224.0.0.1 ~239.255.255.254)

Page 82 of the Planet Technology WSD-800 user manual — 4.9.4 IGMP Group Policy
Page 82 · click to enlarge
Page 82
„ DeleteDelete an exist Multicast Group entry

„ Port: Indicates the port , assigned to send and receive all traffic for particular multicast groups

„ Index: Field in the index number that mapping to the multicast group. A port can be assigned up to 24

static Multicast groups. 0 means to delete all policy

Planet Technology WSD-800 — 4.9.4 IGMP Group Policy diagram (page 82)
Fig. 117 · 4.9.4 IGMP Group Policy

Configure Sample:

1. Select the Index field in the Set IGMP Group Policy Table, in this case, filed in index “ 1 ” with Multicast Group

“239.1.1.1”

2. Click on the “OK” button to save.
3. The Multicast Group entry will be add to the IGMP Group Policy Table.
4. Select the specific port that will be assigned to force accept static Multicast Group stream.
5. Field in the Index number that assigned with “239.1.1.1. ( For this case, Select Port-1 with index 1)
6. Click on the “Add” button to take effect.

IGMP Group-Policy Application · IGMP Group-Policy Application

Page 83 of the Planet Technology WSD-800 user manual — 4.9.4 IGMP Group Policy
Page 83 · click to enlarge
Page 83
Planet Technology WSD-800 — 4.9.4 IGMP Group Policy diagram (page 83)
Fig. 118 · 4.9.4 IGMP Group Policy
Page 84 of the Planet Technology WSD-800 user manual — 4.9.5 Static Routing Port
Page 84 · click to enlarge
Page 84

4.9.5 Static Routing Port

This function is to configure ports to be the member of IGMP Groups in VLANs.

To do this, fill the Port List field and the VID field for the static routing and click on the “Add” button to save.

Planet Technology WSD-800 — 4.9.5 Static Routing Port diagram (page 84)
Fig. 119 · 4.9.5 Static Routing Port

Static Routing Port Configuration

„ Port ListManual specifies the ports which send and receive multicast traffic (e.g. 1-3,7)

„ VID: The VLAN-ID of the Static Routing Port.

The range is between 1~4094; VLAN 0 means All VLAN

Multicast VLAN Tunnel Configuration

„ Multicast VLAN TunnelEnable or Disable Multicast groups stream be transmitted cross VLANs
„ Multicast group member VLAN-IDSpecifies the VLAN to be member of the Multicast groups and

crossed from the VLAN at Static Routing Port Configuration. There’re up to 28 VLAN members. Once

the VLAN members and the VLAN of Static Routing Port are assigned, all the Multicast group stream at

the VLAN of Static Routing Port will be forwarded to member VLANs.

Planet Technology WSD-800 — 4.9.5 Static Routing Port diagram (page 84)
Fig. 120 · 4.9.5 Static Routing Port

Configure Sample:

To realize the Multicast traffic cross over different VLANs, the IGMP Snooping protocol and VLAN protocol have to

cooperate with each other. First we have to assign the Static Routing Port to the specify port with VLAD ID, and

then add VLANs to be the multicast group members. After that, ports belong to the member VLANs are able to

receive multicast traffic cross VLAN. But they are not able to access each other.

Page 85 of the Planet Technology WSD-800 user manual — 4.9.5 Static Routing Port
Page 85 · click to enlarge
Page 85

„ Static Routing Port and Multicast group VLAN member configue

1. Enable IGMP Snooping, as the following screenshot:
Planet Technology WSD-800 — 4.9.5 Static Routing Port diagram (page 85)
Fig. 121 · 4.9.5 Static Routing Port
2. Assign the member VLANs which will receive Multicast group traffic cross different but source VLAN. In this

case, we add VLAN 2 and VLAN 3 as the Multicast group memebers.

3. Assign the Static Routing Port, here we assign Port-2 as the Static Routing Port of VLAN 6 . As following

screen appears.

Page 86 of the Planet Technology WSD-800 user manual — „ VLAN configure
Page 86 · click to enlarge
Page 86
Planet Technology WSD-800 — 4.9.5 Static Routing Port diagram (page 86)
Fig. 122 · 4.9.5 Static Routing Port
Planet Technology WSD-800 — 4.9.5 Static Routing Port diagram (page 86)
Fig. 123 · 4.9.5 Static Routing Port

Port. Or the function will not work properly.

„ VLAN configure

4. Set the VLAN mode to be 802.1Q VLAN
5. At Step-3, we had set Port-2 as VLAN 6 Static Routing Port, so we have to configure Port-2 as VLAN 6

member port.

Planet Technology WSD-800 — „ VLAN configure diagram (page 86)
Fig. 124 · „ VLAN configure
6. Cooperate with IGMP Snooping,and 802.1Q VLAN,Port-6 of VLAN 2 and Port-7 of VLAN 3 are able to

receive the Multicast group traffic from Port-2 with different VLAN groups setting

Page 87 of the Planet Technology WSD-800 user manual — 4.10.2 Port Mirror
Page 87 · click to enlarge
Page 87

4.10 Port Analysis

4.10.1 Port Analysis

This function shows the statistical information of each port, it helps to diagnose the network malfunction.

The following example shows the statistic table of port #6.

Planet Technology WSD-800 — 4.10 Port Analysis diagram (page 87)
Fig. 125 · 4.10 Port Analysis

4.10.2 Port Mirror

Port Mirroring is a method of monitoring network traffic that forwards a copy of each incoming and/or outgoing

packet from one port of a network switch to another port where the packet can be studied. It enables the manager

to keep close track of switch performance and alter it if necessary.

Configuring the port mirroring by assigning a source port from which to copy all packets and a sniffer port where

those packets will be sent.

Capture Port: Use this option to select the destination port for monitored traffic. This is the port that your network

analyzer would be connected to.

Ingress Port: Duplicate the date transmitted from the source port and forward it to the Capture port.

Egress Port: Duplicate the data sent to the source and forward it to the Capture port.

Page 88 of the Planet Technology WSD-800 user manual — 4.11 Storm Control
Page 88 · click to enlarge
Page 88
Planet Technology WSD-800 — 4.11 Storm Control diagram (page 88)
Fig. 126 · 4.11 Storm Control

4.11 Storm Control

This function is to control the Braodcast Storm, Multicast Storm and Flooded Storm packet on each port.

To configure the Storm Control, click on the Storm Control menu button. The web main page then shows the

Strom Restricting function table.

1. Fill the Port List field in the Broadcast Storm Restricting table, select the type in the Restricting Type drop

down menu and enter the packet size in the Flow field.

2. Click on the “OK” button to save.
3. To remove the Storm Restricting function on the port, simpy click on the “Delete” button in the Show Port

Restricting Table table.

Planet Technology WSD-800 — 4.11 Storm Control diagram (page 88)
Fig. 127 · 4.11 Storm Control
Page 89 of the Planet Technology WSD-800 user manual — 4.12.2 IP Stacking Configuration
Page 89 · click to enlarge
Page 89

4.12 IP Stacking

4.12.1 About IP Stacking

IP Stacking function enables you to use a single IP address and standard network cabling to manage a group of

up to 8 PLANET WSD-800 / WGSD-910 / WGSD-1022C / WSW-2401A / WGSW-2840 / WGSW-5240 Switches in

the same IP subnet (broadcast domain).

Once one switch had been operated as the Master of a stack, additional switches can join the IP stack by manual

methods to setting with the same group name. After a switch becomes a Client and stack group member, you can

work through the Master switch to further configure the Member switch as necessary for all of the IP Stack

features available in the switch.

Planet Technology WSD-800 — 4.12.1 About IP Stacking diagram (page 89)
Fig. 128 · 4.12.1 About IP Stacking

4.12.2 IP Stacking Configuration

Before the IP Stacking Configuration, the network manager have to identify the roles of the stackable switches –

the Master mode and Client mode. At a IP stacking group domain, there is only one Master switch and many

Client switches. If there’re more than one switch be configured to the Master mode, the it will depends on the

“System Priority” to elect a active Master. The others with Master mode would be Backup Master.

To join a IP Stack group, both the Master and Client have to be assigned with the same string at “IP Stacking

Group” filed.

Once the switch be assigned as a Client switch, it’s not allowed to management the Client switch with its original

system IP address. That is, the administrator has to configure the Client switch via the Master switch

mamagement UI.

The following fields can be set for IP Stacking configuration:

Current modeDisplay the current mode of IP Stacking, there’re three possible statuses:
  • Disable – The IP Stacking function is disabled.
Page 90 of the Planet Technology WSD-800 user manual — 4.12 IP Stacking
Page 90 · click to enlarge
Page 90
  • Master – The IP Stacking Management status is enabled and the current switch is a Master switch at this

IP Stack Group.

  • Client.- The IP Stacking Management status is enabled and the current switch is a Client switch at this IP

Stack Group.

Manamement status: This filed is to Enable or Disable the IP Stack function.

Management modeIdentify the management mode of the current switch. There’re two possible selections:
  • Master – The switch plays as a Master of the IP Stack Group.
  • Client - The switch plays as a Client of the IP Stack Group.

IP Stacking group: This filed effects if the switches be joined to the same IP Stack group. With the same “string”

entry, both the Master and Client will be assigned to the same IP Stack group. If not, the switches will not be the IP

Stack group members.

System priority: If there’re more than one switch be configured to the Master mode, the it will depends on the

“System Priority” to elect a active Master. The others with Master mode would be Backup Master. If there is no

other Master switch, it’s no need to modify this value.

IPStacking MAC: The Master will base on the MAC address to find out the Cleint switches. Generally the entry

would be the burn-in MAC address of the switch.

Stack name: Identify the name at a IP Stack group. The entry will be displayed at the Master switch management

UI for Master and Client switches identify.

Following we’ll show you how to configure the Master switch and Client switch.

  • Master Switch configuration
1. Please enter into switch web main screen and choose “Enable” in Management status field. It will enable the

stack function of the switch and the following screen appears.

Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 90)
Fig. 129 · 4.12 IP Stacking
2. Then assign a role to the WSD-800 / WGSD-910 / WGSD-1022C / WSW-2401A / WGSW-2840 /
Page 91 of the Planet Technology WSD-800 user manual — 4.12 IP Stacking
Page 91 · click to enlarge
Page 91

WGSW-5240 Switches as Master in Management mode field, the following screen appears.

Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 91)
Fig. 130 · 4.12 IP Stacking
3. Enter a string in the “IP Stacking Group” field; the default string of the WSD-800 / WGSD-910 / WGSD-1022C

/ WSW-2401A / WGSW-2840 / WGSW-5240 Switches is “planet_switch”. This string must be the same with

the Client switches that to be assigned to the same IP Stack group.

4. Modify the “System priority” and “Stack name” if necessary. At this sample we change the Stack name of the
5. Click “ OK ” if the configuration is down.
  • Client Switch configuration
6. Please enter into Client switch web main screen and choose “Enable” in Management status field. It will

enable the stack function of the switch.

7. Then assign a role to the WSD-800 / WGSD-910 / WGSD-1022C / WSW-2401A / WGSW-2840 /

WGSW-5240 Switches as Client in Management mode field, the following screen appears.

Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 91)
Fig. 131 · 4.12 IP Stacking

Master to “Switch-1”

Page 92 of the Planet Technology WSD-800 user manual — 4.12 IP Stacking
Page 92 · click to enlarge
Page 92
8. Enter a string in the “IP Stacking Group” field; the default string of the WSD-800 / WGSD-910 / WGSD-1022C

/ WSW-2401A / WGSW-2840 / WGSW-5240 Switches is “planet_switch”. This string must be the same

with the Master switch that to be assigned to the same IP Stack group.

Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 92)
Fig. 132 · 4.12 IP Stacking
9. Modify the “ System priority ” and “ Stack name ” if necessary. At this sample we change the Stack name of

the Client to “Switch-2”

10. Click “ OK ” if the configuration is down.
11. Please use a UTP cable to uplink together through its Ethernet interface
12. Back to login the WEB main screen of Master switch - then you can see two WGSW-2840 stacks together

from its web interface. The following screen appears.

Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 92)
Fig. 133 · 4.12 IP Stacking
13. After setup complete, please go to system and choose “Saving parameters” to save current configuration.

The following screen appears.

Page 93 of the Planet Technology WSD-800 user manual — 4.12 IP Stacking
Page 93 · click to enlarge
Page 93
Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 93)
Fig. 134 · 4.12 IP Stacking
Planet Technology WSD-800 — 4.12 IP Stacking diagram (page 93)
Fig. 135 · 4.12 IP Stacking

device with minimum MAC address.

Page 94 of the Planet Technology WSD-800 user manual — 5.2 Diagnosing LED Indicators
Page 94 · click to enlarge
Page 94

5. TROUBLE SHOOTING

This section is intended to help you solve the most common problems on the WSD-800 / WGSD-910 Managed

5.1 Incorrect connections

The switch port can auto detect straight or crossover cable when you link switch with other Ethernet device. For

the RJ-45 connector should use correct UTP or STP cable, 10/100Mbps port use 2 pairs twisted cable. If the

RJ-45 connector is not correct pin on right position then the link will fail. For fiber connection, please notice that

fiber cable mode and fiber module should be match.

5.1.1 Faulty or loose cables

Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. IF

that does not correct the problem, try a different cable.

5.1.2 Non-standard cables

Non-standard and miss-wired cables may cause numerous network collisions and other network problem, and can

seriously impair network performance. A category 5-cable tester is a recommended tool for every 100Base-T

network installation.

5.1.3 Improper Network Topologies

It is important to make sure that you have a valid network topology. Common topology faults include excessive

cable length and too many repeaters (hubs) between end nodes. In addition, you should make sure that your

network topology contains no data path loops. Between any two ends nodes, there should be only one active

cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network

performance.

5.2 Diagnosing LED Indicators

The Switch can be easily monitored through panel indicators to assist in identifying problems, which describes

common problems you may encounter and where you can find possible solutions.

IF the power indicator does turn on when the power cord is plugged in, you may have a problem with power outlet,

or power cord. However, if the Switch powers off after running for a while check for loose power connections,

power losses or surges at power outlet. IF you still cannot resolve the problem, contact your local dealer for

assistance.

Ethernet Switch

Page 95 of the Planet Technology WSD-800 user manual — 5.2.1 Cabling
Page 95 · click to enlarge
Page 95

5.2.1 Cabling

RJ-45 portsuse unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω

Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5 cable for 100Mbps connections. Also be

sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

Page 96 of the Planet Technology WSD-800 user manual — 6. APPENDIX
Page 96 · click to enlarge
Page 96

6. APPENDIX

6.1 Console Port Pin Assignments

The DB-9 serial port on the front panel is used to connect to the switch for out-of-band console configuration. The

console menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation

program. The pin assignments used to connect to the serial port are provided in the following tables.

Planet Technology WSD-800 — 6. APPENDIX diagram (page 96)
Fig. 136

DB-9 Console Port Pin Numbers

DB-9 Port Pin Assignments

Planet Technology WSD-800 — 6. APPENDIX diagram (page 96)
Fig. 137

Console Port to 9-Pin DTE Port on PC

Planet Technology WSD-800 — 6. APPENDIX diagram (page 96)
Fig. 138

Switch’s 9-Pin Serial Port CCITT Signal PC’s 9-Pin DTE Port

Cable Types and Specifications

Planet Technology WSD-800 — 6. APPENDIX diagram (page 96)
Fig. 139

10BASE-T Cat. 3, 4, 5100-ohm UTP 100 m (328 ft) RJ-45

Page 97 of the Planet Technology WSD-800 user manual — 6.2 100BASE-TX/10BASE-T Pin Assignments
Page 97 · click to enlarge
Page 97
Planet Technology WSD-800 — 6.2 100BASE-TX/10BASE-T Pin Assignments diagram (page 97)
Fig. 140 · 6.2 100BASE-TX/10BASE-T Pin Assignments

100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45

100BASE-FX 50/125 or 62.5/125 micron core multimode fiber (MMF) 2 km (1.24 miles) SC or ST

6.2 100BASE-TX/10BASE-T Pin Assignments

With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 for receiving

data.

Planet Technology WSD-800 — 6.2 100BASE-TX/10BASE-T Pin Assignments diagram (page 97)
Fig. 141 · 6.2 100BASE-TX/10BASE-T Pin Assignments

All ports on this switch support automatic MDI/MDI-X operation, you can use straight-through cables for all

network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6,

at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table

below shows the 10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.

Planet Technology WSD-800 — 6.2 100BASE-TX/10BASE-T Pin Assignments diagram (page 97)
Fig. 142 · 6.2 100BASE-TX/10BASE-T Pin Assignments

1 Receive Data plus (RD+) Transmit Data plus (TD+)

2 Receive Data minus (RD-) Transmit Data minus (TD-)

3 Transmit Data plus (TD+) Receive Data plus (RD+)

6 Transmit Data minus (TD-) Receive Data minus (RD-)

RJ-45 Pin Assignments

Page 98 of the Planet Technology WSD-800 user manual — 7. APPENDIX-B
Page 98 · click to enlarge
Page 98

7. APPENDIX-B

„ 802.1Q VLAN Multi-Untagged VLAN setting sample 1

The version V.1.4.27 of PLANET IP Stackable series had added the multiple untagged VLAN function on a port.

The function could be applied at if the members of two or more different VLAN groups all have to access the same

server/AP/Printer. But the two VLAN groups are separated and can’t access to each other. The graphic in Figure

7-1 appears.

Planet Technology WSD-800 — 7. APPENDIX-B diagram (page 98)
Fig. 143

Figure 7-1 Overlap VLAN graphic

The next will be a configure sample- how to setup the WGSW-2840 802.1Q VLAN with a multiple untagged port.

1. At the menu bar ,click “ Security ” > “ VLAN ”
2. After the VLAN configuration page appear, select “ 802.1Q VALN “ and clink “ OK ” to apply. Then the following

screen in Figure 7-2 appears.

Page 99 of the Planet Technology WSD-800 user manual — 7. APPENDIX-B
Page 99 · click to enlarge
Page 99
Planet Technology WSD-800 — 7. APPENDIX-B diagram (page 99)
Fig. 144

Figure 7-2 802.1Q VLAN page screen

3. Move the mouse course to the port, which had be assigned to be connect to the server/AP/printer, then click

on the port. For this case, we set the Port-1 to be the multiple untagged port. The screen in Figure 7-3

appears.

4. At the Link Type, select “ Always Untag ” at the draw bar. Click “OK” to apply.
Planet Technology WSD-800 — 7. APPENDIX-B diagram (page 99)
Fig. 145

Figure 7-3 802.1Q VLAN Port Configuration – Port1 screen

5. Click the “ Add/Modify ” button to create new VLAN groups with VID=2 and VID=3.
6. At the Port 1VLAN Port configuration page, select VLAN 2 and VLAN 3 to add to the Port 1 . The right

information window at this table shows the status. The screen in Figure 7-4 appears.

Page 100 of the Planet Technology WSD-800 user manual — 7. APPENDIX-B
Page 100 · click to enlarge
Page 100
Planet Technology WSD-800 — 7. APPENDIX-B diagram (page 100)
Fig. 146

Figure 7-4 Assign Port-1 to be VLAN 2 and VLAN 3 member.

7. After the down the Port 1 VLAN configuration, press “ close ” to back to the 802.1Q VLAN main screen. And

check if the setting be applied to Port 1 at the “Egress Policy” column. The screen in Figure 7-5 appears.

Planet Technology WSD-800 — 7. APPENDIX-B diagram (page 100)
Fig. 147

Figure 7-5 Port 1 VLA N status

8. Assign the VLAN 2 and VLAN 3 group member. At this case, Port 2 had been assigned to as VLAN 2 group

member and Port 3 be assigned to as VLAN 3 group member.

9. Repeat step 2 to step 7, expect that :
  • Configure the Port 2 with PVID=2 , Port 3 with PVID=3 .
  • The link type of both Port-2 and Port 3 are “ Always Untag ”.
  • And both Port 2 and Port 3 are VLAN 1 members.
10. After properly configure the 802.1Q VLAN per port setting, it should be as the screen in Figure 7-6 appears.
Page 101 of the Planet Technology WSD-800 user manual — „ 802.1Q VLAN - Multi-Untagged VLAN setting sample 2
Page 101 · click to enlarge
Page 101
Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 101)
Fig. 148 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 2

Figure 7-6 Port 1, Port 2 and Port 3 VLAN configuration

Although Port 2 and Port 3 are VLAN 1 members, with different PVID setting, the two ports are not able to access

each other. But they all can access with the server/AP/Printer which connect to the Port 1 now.

„ 802.1Q VLAN - Multi-Untagged VLAN setting sample 2

Planet Technology WSD-800 — „ 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 101)
Fig. 149 · „ 802.1Q VLAN - Multi-Untagged VLAN setting sample 2
Page 102 of the Planet Technology WSD-800 user manual — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2
Page 102 · click to enlarge
Page 102

„ VLAN Group Membership

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 102)
Fig. 150 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 2

„ WGSW-2840_192.168.0.222 Core-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 102)
Fig. 151 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 2

„ WGSW-2840_192.168.0.10 Edge-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 102)
Fig. 152 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 2

„ WGSW-2840_192.168.0.20 Edge-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2 diagram (page 102)
Fig. 153 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 2
Page 103 of the Planet Technology WSD-800 user manual — 802.1Q VLAN - Multi-Untagged VLAN setting sample 2
Page 103 · click to enlarge
Page 103

Port3 Always Untag 1 Untag=1,2,3,4 NtworkPrinter

Port28 Trunk 1 Tag=1,2,3,4 Core-2840

„ WGSW-2840_192.168.0.30 Edge-Switch VLAN Configuration

192.168.0.30 VLAN Configuration

Port Link Type PVID Egress Link Partner

Port1 Always Untag 4 Untag=1,4 PC

Port2 Always Untag 4 Untag=1,4 PC

Port3 Always Untag 4 Untag=1,4 PC

Port28 Trunk 1 Tag=1,2,3,4 Core-2840

Page 104 of the Planet Technology WSD-800 user manual — WGSW-2840_10
Page 104 · click to enlarge
Page 104

„ 802.1Q VLAN - Multi-Untagged VLAN setting sample 3

Planet Technology WSD-800 — „ 802.1Q VLAN - Multi-Untagged VLAN setting sample 3 diagram (page 104)
Fig. 154 · „ 802.1Q VLAN - Multi-Untagged VLAN setting sample 3

„ VLAN Group Membership

VLAN ID VLAN Define Major Member

VLAN 1 Public VLAN WGSW-2840_220

WGSW-2840_10

WGSW-2840_20

WGSW-2840_30

VLAN 2 Client connect to Ports those be assigned to VLAN 2 ,at

[192.168.0.10] switch

Client connect to Ports those be assigned to VLAN 2 ,at

[192.168.0.20] switch

Client connect to Ports those be assigned to VLAN 2 ,at

[192.168.0.30] switch

VLAN 3 Client connect to Ports those be assigned to VLAN 3 ,at

[192.168.0.10] switch

Client connect to Ports those be assigned to VLAN 3 ,at

Server · Network_Printer_1 · Network_Printer_2

Page 105 of the Planet Technology WSD-800 user manual — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3
Page 105 · click to enlarge
Page 105
Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3 diagram (page 105)
Fig. 155 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 3

Client connect to Ports those be assigned to VLAN 3 ,at

VLAN 4 Client connect to Ports those be assigned to VLAN 4 ,at

Client connect to Ports those be assigned to VLAN 4 ,at

Client connect to Ports those be assigned to VLAN 4 ,at

„ WGSW-2840_192.168.0.222 Core-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3 diagram (page 105)
Fig. 156 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 3

„ WGSW-2840_192.168.0.10 Edge-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3 diagram (page 105)
Fig. 157 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 3

„ WGSW-2840_192.168.0.20 Edge-Switch VLAN Configuration

Planet Technology WSD-800 — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3 diagram (page 105)
Fig. 158 · 802.1Q VLAN - Multi-Untagged VLAN setting sample 3
Page 106 of the Planet Technology WSD-800 user manual — 802.1Q VLAN - Multi-Untagged VLAN setting sample 3
Page 106 · click to enlarge
Page 106

„ WGSW-2840_192.168.0.30 Edge-Switch VLAN Configuration

192.168.0.30 VLAN Configuration

Port Link Type PVID Egress Link Partner

Port1 Always Untag 2 Untag=1,2 PC

Port2 Always Untag 3 Untag=1,3 PC

Port3 Always Untag 4 Untag=1,4 PC

Port28 Trunk 1 Tag=1,2,3,4 Core-2840

Part No. 2081-A92310-002

Ask about the Planet Technology WSD-800

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology WSD-800

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology WSD-800 manual PDF

106 pages·2.9 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…