PostPerfect ™ B700 Postage Meter Quick Start Installation Instructions

Before you do anything else, read this booklet. It explains how to install your meter, how to put postage in it and how to select and print postage.

Second Edition, July, 1995 ©1995 Pitney Bowes Inc. All rights reserved. This book may not be reproduced in whole or in part in any fashion or stored in a retrieval system of any type or transmitted by any means, electronically or mechanically, without the express, written permission of Pitney Bowes.
POSTAGE BY PHONE is a registered trademark of Pitney Bowes. PB SUPPLY LINE is a service mark of Pitney Bowes.
Printed on recycled paper

Setup and Operating Guide Quick Reference Guide Quality Card Meter Carrying Case Postage Meter Stacker Assembly Keys (2)
Power Cord Ribbon Cassette Supply Kit Postal Documents POSTAGE BY PHONE® Letter (this has important informa- tion about your POSTAGE BY PHONE account. You’ll need to refer to it when you put postage in your meter.)
If anything is missing, please call the number given on page 7 of this booklet. See the figure below for a brief introduction to your new meter.

Operator Display—shows you the current status of the meter
Feed Deck—Supports your envelope or tape sheet as it passes through print area
Printhead—Applies meter impression to your envelopes and tape sheets


Remove the meter from its carrying case and place it on your work surface, close to a properly grounded 120 VAC wall outlet. Choose a convenient loca- tion—one where you have enough room to estab- lish an efficient work flow.
a. Connect the power cord to the receptacle at the back of the meter as shown. b. Connect the power cord to a properly grounded 120 VAC wall outlet.

a. Unpack the ribbon cassette and remove the shipping tab. If nec- essary, turn the winder counter- clockwise to remove any slack from the ribbon.


c. Hold the cassette with the rib- bon side down and the cutout aligned with the printhead. Align the locating tab on the right side of the cassette with the groove in the cassette compart- ment.
D d. Rest the cassette on the deck and push it back into the ribbon compartment as far as it will go.
e. Press in on the top of the cassette near the locking tab to snap it in position.
Close the cassette compartment door. This completes ribbon loading.


a. The lock is on the right side of the meter as seen from the front.
b. Insert the key in the lock.
c. Turn the key to the right (clockwise) to unlock the meter.
After you turn it on, the meter performs a self test for several seconds and you'll hear it run briefly.
d. The meter displays “Insuf Funds.” Now you're ready to put postage into your meter for the first time. You need:
Your Pitney Bowes POSTAGE BY PHONE® Account Number. The letter you received from Pitney Bowes contains this number. Write it down in the space provided in the gray box on page 6 of these instructions.
To telephone the POSTAGE BY PHONE Data Center to get a combination num- ber as explained in the instructions that follow. The Data Center is open from 8:00 A.M. to 8:00 P.M. Eastern Time, Monday through Friday, and 8:00 A.M. to 3:00 P.M., Eastern Time, Saturday. It is closed on Sundays and certain holidays.

a. Press Refill.
b. The display prompts “Enter Amnt” alternating with the default re- fill amount ($200).
c. To accept the default amount, press En- ter and go to step e. To enter your own refill amount, go to step d.
d. Use the number keys to type in the post- age amount you want. Note that:

e. Press Enter.

g. Place a spare envelope or piece of stiff paper (such as an index card) on the trans- port. Insert it from the left and guide it up against the rear wall (1); then slide it to the right (2) up to the trip mark as shown and release it. The display prompts “Print- ing...” and the meter prints a refill report similar to this:

20000003 10:48a REFILL REPORT 03 / 07 / 95
PHONE NUMBER SERIAL NUMBER ACCESS CODE REFILL AMOUNT COMBINATION
Sample Refill Report (Your Report Will Look Different)
At the Phone— Have your POSTAGE BY PHONE® account number and your refill report at hand when you call; the Pitney Bowes POSTAGE BY PHONE Data Center will ask you for some of the information on your refill report. If you need help during the transaction, press the telephone keys shown on the next page.

4 * to end the call * 0 to speak to a customer assistance representative
What You Hear What You Do
a. From a touchtone phone, call the POST- AGE BY PHONE® Data Center.
At the telephone, press 5 5 5, followed by the # (pound) key.
Write your POSTAGE BY PHONE account number here:
At the telephone, enter your 8-digit POST- AGE BY PHONE account number, followed by the # key.
At the phone enter your meter's serial number (from refill report) followed by the # key.
At the phone enter the meter access code (from refill report) followed by the # key.
At the phone enter the postage reset dol- lar amount (from refill report) followed by the # key.
At the phone press the # key if the reset dollar amount is OK; if not, enter the cor- rect amount followed by the # key.

Write this number in the space provided on your refill report.
At the telephone press 7 followed by the * (asterisk) to hear the setting/combina- tion number again.
Make sure the setting/combo number you wrote in step h is correct.
Press 4 and * to end the call.
Completing the Refill at Your Meter a. The meter prompts: “Enter Combo.”
b. Use the meter's number keys to type the setting/combination number the Data Center gave you in step h above. Press Enter.
c. If the refill is successful, the display briefly shows “Refill OK” and then “$Avail= XXX.XX” where XXX.XX is the postage amount now available. (If the refill amount you asked for was $50.00 or less, the meter displays “Low Funds.” This is normal. As delivered, your meter is set to show this warning when the postage available reaches or falls below $50.00.)
d. If the refill was not successful, the display will show “Failed” for two seconds and then “Insuf Funds.” If this happens, or should you have other problems with your meter after following the steps in this installation guide, please call:
1-800-562-8237
The Direct Distribution Help Line is available Monday through Friday between the hours of 8:00 A.M. and 8:00 P.M., Eastern Standard Time.
Congratulations! Your meter is now installed, filled with post- age and ready to go to work for you. The instructions on the next two pages tell you how to process mail. If your meter is equipped with the optional Electronic Interface (DataLink) fea- ture, follow the setup and operating instructions furnished with it. See page 11 of this booklet.


Slide the stacker up against the right side of the meter and posi- tion it as shown. The stacker sits next to the meter. It's not physi- cally connected to it. In this posi- tion, the stacker can handle enve- lopes up to #10. If you're using longer envelopes, move the stacker to the right to accommodate them.
a. The display normally shows the default postage amount shown at the right. This is usually the rate for first class letter mail weighing up to one ounce.
b. At the keyboard type a 0 (zero) and then Enter.
c. The display now shows zero as the postage value. The meter is ready to use when the amount you entered is bracketed by three bars as shown.
d. Place a sample envelope on the feed deck face up and push it against the rear wall of the meter (1).

e. Slide the enve- lope to the right (2) until its lead edge touches the trip mark on the feed deck.
f. The meter will sense the pres- ence of the envelope, convey it through the print area and into the stacker. The meter impression should look similar—but not necessarily identical—to that shown in the figure at the top of the next page.


a. If you want to accept the default value displayed by the meter, press Enter and go to step d. To enter a different postage value, go to step b.
b. Use the number keys to type in the postage value you want. For example, to key in 64¢, press:
You don’t have to type a decimal point. The meter automatically adds it.
c. Press Enter to confirm the postage value. The three bars on either side of the postage display tell you the meter is ready to print postage as shown below.
d. Place your envelope on the transport face up and push it against the rear wall of the meter. Slide the envelope to the right until its lead edge touches the trip mark on the feed deck. See the figure at the bottom of the previous page.
e. The meter senses the presence of your envelope, then conveys it into the print area and out to the stacker.
f. You can insert the next envelope as soon as the previous one enters the stacker.

The Quick Reference Guide in- cluded with your documentation package provides brief step-by-step instructions for the procedures you’ll use most often. Place the guide in the cassette compartment as shown in the accompanying figure.

Your meter is designed to streamline your mail processing and accounting procedures. A comprehensive user’s guide is packed with it. Please take a few minutes to go through the manual; it explains everything you need to know to take full advantage of the many useful features built in to your meter.
Pitney Bowes offers several options designed to enhance the operation and expand the capabilities of your postage meter. These include:
K A moistener—moistens and help seals envelopes as they feed through the meter. K Advertising slogan cartridge—lets you select additional meter ads and inscriptions. Pitney Bowes offers a wide range of standard meter ads to turn your unused envelope space into a hard-working promotional tool. You can also order custom ads to personalize and add impact to your mailings. K An Electronic Interface Unit (DataLink)—expands account capacity to 100 and provides communication ports for connection to a Pitney Bowes electronic scale, a PC or serial printer, and a modem for one-button postage refill. See facing page. Pitney Bowes also offers a full complement of supplies for your meter, including: K Replacement Ribbon Cassettes K Postage Tape Sheets K E-Z® Seal Sealing Solution For more information, or to place an order, call the:
Please take a moment or two to fill out the Quality Card included with your documentation package and print a register report on it as follows:
a. Press the Value/Pieces key. b. Place the Quality Card on the meter’s feed deck, as though you were about to print postage. Guide the card up against the rear wall and to the right, up to the trip mark. c. The display prompts “Reg Report Press Enter.” Press Enter. The meter prints a register report on your quality card. d. Drop the card in the mail. Thank you.


If so, it’s equipped with an expansion DataLink module, also known as an Electronic Interface Unit. It’s easy to set up and use and greatly enhances the capabilities of your meter as described on the previous page. It comes with a modem and its own set of step-by-step installation and user instructions (Pitney Bowes Publication SV 50394). Please read and follow the instructions carefully and you’ll be rewarded with an exceptional set of performance features.