Installation and Operating Instructions Sizes and Specifications Custom Pass-Thru Cabinets – Self Contained
* Energy Star approved (solid doors only). **Voids Energy Star approval.
![Perlick PS84 — 84” [2134] 3 DOOR 60” [1524] 2 DOOR diagram (page 2)](/cdn/reader/04/046fc5e75accbe2fdf3763cb304c8c5ca3eff421dd53ccc3dbedceba7da8392c/images/fig-2-1.webp)
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2279 Rev 08.01.07
![Page 3 of the Perlick PS84 user manual — 72” [1829] 3 DOOR 48” [1219] 2 DOOR](/cdn/reader/04/046fc5e75accbe2fdf3763cb304c8c5ca3eff421dd53ccc3dbedceba7da8392c/images/page-3.webp?w=400)
![Perlick PS84 — 72” [1829] 3 DOOR 48” [1219] 2 DOOR diagram (page 3)](/cdn/reader/04/046fc5e75accbe2fdf3763cb304c8c5ca3eff421dd53ccc3dbedceba7da8392c/images/fig-3-1.webp)
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Installing Legs (Optional)
Attach four legs to the cabinet bottom. Use the supplied 1/4”- 20 x 3/4” hex head self-tapping machine screws.
Placing the Cabinet
Position the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit.
Leveling the Cabinet
Before operating the cabinet, the condensate drain tube (furnished) must be connected. One end is attached to the barbed elbow on the evaporator condensate pan. The other end is inserted through evaporator drain hole and exits the bottom of the cabinet. The drain hole is located in the cabinet floor pan, behind the vertical door mullion. The drain tube must be placed over a floor drain or into a condensate management system such as a “CONDENSATE EVAPAWAY” pan and heater.
When the cabinet is in place, check installation with carpenter’s level. When level front to back and left to right, accumulated water will drain out of cabinet evaporator drain.
A 115-volt electric condensate pan can be installed underneath the cabinet to collect and evaporate the condensate from the cabinet evaporator. A 6 foot - 3 prong plug is included. A separate circuit should be provided for the heater. The kit can be used only on cabinets with 4” minimum legs. It can not be used with platform or baseplate kits..
The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.
Attach brackets to cabinet bottom in holes pro- vided. Attach base plate to brackets. (See separate instructions, provided with kit). When returning cabinet to upright position, be careful not to bend brackets.
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit.
To avoid compressor damage,after returning cabinet to an upright position, let unit stand for 24 hours before plugging it in and running the unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2279 Rev 08.01.07

The condenser fan motor turns off and on with the compressor. The evaporator fan motor is on all the time.
The cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.
Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. Note: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.
OFF
Adjusting the temperature
Cleaning the Condenser
The temperature control is inside the cabinet on the left-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.
Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure efficient operation. Caution: Do not bend the fins while brushing the front of the condenser.
The condenser (located behind the front grille cover) should be inspected every 30 days and cleaned, if necessary.
Failure to keep the condenser clean will cause a loss in condensing unit efficiency.
* Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.Omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on the package. Note: Do Not Use Steel Wool or Scouring Pads to clean stainless steel.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
COLDer

*Contact Perlick Milwaukee for complete door replacement. Cabinet serial no. required.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2279 Rev 08.01.07

Top Hinge Bracket Bottom Hinge Bracket
Right Hinged Door (as shipped from factory)
Operations to Perform on Cabinet
Step #12 Step #11 Step #13
Top Hinge Bracket Bottom Hinge Bracket
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.


Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.