Installation & Operation Manualp.1Commercial Back Barp.1Models BBRN & BBSN Seriesp.1Introductionp.2Warrantyp.2WARNING Indicates a hazard MAYp.2CAUTION Indicates a hazard wherep.2DANGER Indicates a hazard that WILLp.2Uncrating and Inspectionp.3CAUTION Do not cut cardboardp.3CAUTION If unit has been laid on itsp.3CAUTION Do not lift unit by drawer,p.3CAUTION Do not attempt to operatep.3WARNING To prevent personalp.3DANGER ELECTROCUTION HAZARD!p.3CAUTION Finished flooring shouldp.3CAUTION Do not over-tighten drainp.3DANGER Failure to comply with thesep.3General Informationp.4Installing the Unitp.4Preparing the Spacep.4CAUTION Make sure the floor underp.4Electric Condensate Evapaway (Optional)p.4Base Plate Installation (Optional)p.4Casters or Legsp.4Sealing Cabinet to Floorp.5Faucet and Dispensing Head Installationp.5Refrigeration and Temperature Controlp.5Interior Lightp.5Checking Product Temperaturep.5Digital Temperature Controlp.6F Cp.6SETp.6Changing Door Swing Directionp.6SUPPORTp.6BOTTOM VIEWp.7Shelving Adjustmentp.8CAUTION Completely empty shelf orp.8TOP VIEWp.8DANGER Never attempt to repair orp.9LED Light Replacementp.9Stainless Steel Care & Cleaningp.9Cleaning the Condenserp.10Cleaning Cabinet Interior/Exteriorp.10CAUTION NEVER use hydrochloricp.10Recommended Cleaners for Specific Situationsp.11Before Calling For Servicep.12For Product Informationp.13For Replacement Parts and Accessoriesp.13For Product Servicep.13LOST and DAMAGED MERCHANDISEp.20TERMS NET 30 DAYSp.20RETURN OF MERCHANDISEp.20WAIVERp.20METHOD OF SHIPMENTp.20ONE YEAR LABOR WARRANTYp.21ONE YEAR PARTS WARRANTYp.21
Page 1 of the Perlick BBRN user manual — Installation & Operation Manual
Page 1 · click to enlarge
Page 1

Installation & Operation Manual

Commercial Back Bar

Models BBRN & BBSN Series

Perlick BBRN — Installation & Operation Manual diagram (page 1)
Fig. 1 · Installation & Operation Manual

Form No. 2322013

Model BBRN40 Shown

Page 2 of the Perlick BBRN user manual — DANGER Indicates a hazard that WILL
Page 2 · click to enlarge
Page 2

General Information 2 Safety 2 Prior To Installation 3 Installation 4 Operation 5 Adjustments 6 Maintenance 9 Troubleshooting 12 Dimensions 14 Wiring Diagrams 17 Warranty 20

Introduction

Warranty

Congratulations on your purchase of a Perlick commercial back bar product. This manual has been prepared to assist you in the installation of your cabinet and to acquaint you with its operation and maintenance.

To register your product, visit our web site at www.perlick.com Click on “Commercial”, then “Service”. Click on the link “Warranty Registration Form”. You must complete and submit this form or the installation date will revert back to the ship date.

We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval.

Please record the purchase date and the dealer’s name, address and telephone number below.

Model Number: Serial Number: Purchase Date: Dealer Name & Address Phone Number

We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.

PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING an CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit.

WARNING Indicates a hazard MAY

cause serious injury or death if precautions are not followed.

CAUTION Indicates a hazard where

minor injury or product damage may occur if precautions are not followed.

DANGER Indicates a hazard that WILL

result in serious injury or death if precautions are not followed.

All plumbing and electrical work must be performed by a qualified technician and

conform to all applicable state and local codes.

Table of Contents · General Information · Safety

Page 3 of the Perlick BBRN user manual — DANGER Failure to comply with these
Page 3 · click to enlarge
Page 3

Uncrating and Inspection

bottom, of the unit. Both drain ports come plugged from the factory and can be removed if needed. NOTE: Remote units require evaporator condensate to be plumbed to an external drain. Electrical The cabinet must be connected to a separately fused power source (see Electrical Specification Plate affixed to unit) in accordance with National and Local electrical codes.

Remove all crating material. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit.

CAUTION Do not cut cardboard

sleeve covering the unit. Cutting may result in damage to the exterior of the cabinet. Failure to follow this procedure may damage the compressor and void warranty. 1. Uncrate the unit on flat, level surface. Remove the cardboard sleeve by removing the banding securing the sleeve to the shipping base. Carefully lift the cardboard sleeve up over the top of the unit. 2. Carefully lift unit off the base and onto a hand truck or dolly. Make sure unit is balanced on transporting device using soft, flexible strapping. Protect unit surfaces with cloth material where strapping contacts unit.

Self-contained Perlick units come equipped with a NEMA 5-15P 90° plug with an 8’ cord extending beyond the rear of the cabinet. The electrical outlet must be flush with, or recessed into, the wall surface.

CAUTION If unit has been laid on its

back or sides, place unit upright and allow minimum of 24 hours before connecting power. Failure to follow this procedure may damage the compressor and void the warranty.

CAUTION Do not lift unit by drawer,

shelving or door handles or damage to the unit could occur.

CAUTION Do not attempt to operate

the equipment on any other power source than that listed on the Electrical Specification Plate attached to the unit.

WARNING To prevent personal

i n j u r y, t w o p e o p l e minimum required to lift the unit. Larger units may require additional personnel. 3. Before moving unit, secure door(s) to unit with tape to prevent from opening. 4. Carefully move unit to installation site and place in front of opening.

DANGER ELECTROCUTION HAZARD!

  • Electrical grounding is required. Appliances furnished with a 3-prong (grounding) polarized plug are equipped for your protection against possible shock hazards.
  • Never remove the round grounding prong from the plug.
  • Never use a 2-prong adapter.
  • Never use extension cord to connect power to the unit.
  • If a 2-prong receptacle is encountered, or a longer power cord is required, contact a qualified electrician to have it replaced in accordance with applicable electrical codes.

CAUTION Finished flooring should

b e p r o t e c t e d w i t h appropriate material to avoid damage from moving the unit. Plumbing

CAUTION Do not over-tighten drain

fitting or damage to the threads could occur. Condensate from the cooling coil is automatically evaporated from the condensate pan located in the condensing unit housing on self-contained models. Each unit is equipped with a floor drain located in the right rear corner of the cabinet. The drain can be plumbed to an external floor drain by connecting to the 3/4” NPT thread connection on the side, or the 1” NPS thread connection out the

DANGER Failure to comply with these

electrical guidelines may result in possible death or serious injury, fire, or loss of property.

Prior To Installation

Page 4 of the Perlick BBRN user manual — Casters or Legs
Page 4 · click to enlarge
Page 4

General Information

Installing the Unit

  • For units equipped with a power cord, the cord and plug may be aligned with a recess in the back panel to allow the unit to be pushed closer to the wall. For correct alignment, the wall outlet must be located 4” - 10” above the floor.

CAUTION If unit has been laid on its

back or sides, place unit upright and allow minimum of 24 hours before connecting power.

1. With power applied to the unit, check that the lighting and cooling functions operate properly, then turn off power to the wall outlet and/or circuit breaker.
  • Floor must be level in area of installation.

Preparing the Space

2. Position the cabinet into place using rollers when necessary.

CAUTION Make sure the floor under

the unit is level with the surrounding finished floor. Protect a finished floor with plywood, cardboard or some other suitable material before moving the unit into place. Failure to do this may result in damage to the floor.

3. When cabinet is in place, check installation with carpenter’s level. When the unit is level front-to-back and side-to-side, accumulated water will drain out of cabinet to evaporator drain.
4. Turn on power to the outlet and/or circuit breaker.
1. Make sure the space opening is correctly sized for the unit. See Dimension drawings at the back of this manual for correct dimensions.

Electric Condensate Evapaway (Optional)

For installation in areas of high humidity, a 115- volt electric condensate pan can be installed underneath the cabinet to collect and evaporate the condensate from the cabinet evaporator. A 6’ 3-prong plug is included. A separate circuit should be provided for the heater. The kit can be used only on cabinets equipped with 4” minimum legs; it cannot be used on units equipped with platform or base plate kits. Follow instructions supplied with the kit.

2. Check that the following are level and square:
  • Front and interior opening
  • Installation opening and floor surface

Base Plate Installation (Optional)

Once the unit is secured in place, install the base plate brackets to the cabinet bottom in the holes provided. Attach base plate to brackets. Refer to the installation instructions included with the Base Plate Kit.

Casters or Legs

Refer to the instructions included with the Casters or Legs Kit.

Installation

Page 5 of the Perlick BBRN user manual — Checking Product Temperature
Page 5 · click to enlarge
Page 5

Sealing Cabinet to Floor

For units without casters or legs, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor (Figure 1).

Bead Silicon Sealer (RTV)

Figure 1. Sealing Cabinet to Floor

Faucet and Dispensing Head Installation

Refer to the instructions included with the Faucet and Dispensing Head Kit.

Refrigeration and Temperature Control

2. Place the bottle in the desired area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. Adjust the temperature accordingly using the procedures on this page.

The cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of approximately 38° F.

Allow a minimum of 24 hours for ambient temperature product to reach storage temperature.

The following factors affect the internal temperature of the unit:

Draft beer should be stored at a temperature between 32° – 38° F. The most common cause of dispensing problems is improper temperature; beer will foam at warmer temperatures.

  • Temperature setting
  • Room temperature where installed
  • Number of times the door is opened and closed
  • Length of time door is left open
  • Style of door installed
  • Door gasket seal and condition
  • Amount of time the internal light is illuminated
  • Installation in direct sunlight or near a heat source

Beer will freeze at temperatures lower than 30° F. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.

The following chart shows how temperature affects beer:

Interior Light

The unit is equipped with an interior LED light in the upper front of the unit just inside the door or drawer. The light illuminates when the manual rocker light switch is turned on. The rocker light switch is located behind the LED light on the inside of the frame on either the right or left side (same side as the compressor).

Checking Product Temperature

1. To accurately check the temperature of product stored in the refrigerated compartment, insert an accurate thermometer into a plastic unbreakable bottle, partially filled with water. Tighten bottle cap securely.

Cabinet · Floor · Operation

Page 6 of the Perlick BBRN user manual — SUPPORT
Page 6 · click to enlarge
Page 6

Digital Temperature Control

To change the Setpoint:

1. Press the SET button for more than 2 seconds.

F C

2. The value of the setpoint will be displayed and the “C” or “F” LED starts blinking.
3. To change the Set value, press the or button within 10 seconds.

SET

4. To memorize the new setpoint value, press the SET key again, or wait 10 seconds.

Figure 2. Digital Temperature Controller

Changing Door Swing Direction

1. Support the door in the open position as shown in Figure 3. Remove the hinge pin.
2. Pull door to the side and then lower the door.
3. Remove top and bottom hinge brackets. Retain screws for later use. See Figure 4.
4. Remove the hole plugs from the top and bottom hinge bracket mounting holes (Figure 4). Place the plugs in the holes on the opposite side made vacant by removing the hinges in step 3.
Part No. 67439RRight Hinging
Part No. 67439LLeft Hinging
  • Large flat head screwdriver
  • Regular Phillips head screwdriver
  • Hinge Kit from Perlick

Hinge brackets and mounting screws

  • Plastic putty knife

SUPPORT

Hinge brackets and mounting screws

Pull door to the side then lower door

Figure 4. Hinge Removal

Figure 3. Door Removal

Show 6 more labels / short text on this page
Adjustments · Hinge Kits · Tools Required · Hole plugs · Procedure · Remove hinge pin
Page 7 of the Perlick BBRN user manual — BOTTOM VIEW
Page 7 · click to enlarge
Page 7
5. Using the screws removed in step 3, install the top and bottom hinge brackets from kit (Figure 5).

Hinge brackets and mounting screws

Hinge brackets and mounting screws

Corner screws need not be removed to remove front panel

Figure 5. Hinge Installation

Figure 7. Removing Front Panel

6. Remove the top and bottom hinge brackets from the door (Figure 6). Retain the screws for later use.
8. Insert bearing into door top hinge bracket (Figure 8).
9. Insert V-block into door bottom hinge bracket and attach with e-clip (Figure 8). Note the orientation of the V-block.

Hinge brackets and mounting screws

Bearing in door top hinge bracket

Figure 6. Door Brackets

7. Remove the front panel from the door assembly by removing the inner mounting screws, 4 per side, from the perimeter of the door assembly (Figure 7). Rotate the front panel 180°. The top becomes the bottom. Reattach using the same screws and mounting holes.

BOTTOM VIEW

Figure 8. Bearing and V-Block

Show 5 more labels / short text on this page
Front panel · Door bottom bracket · 6° · Orientation · V-block
Page 8 of the Perlick BBRN user manual — TOP VIEW
Page 8 · click to enlarge
Page 8
10. Attach the top and bottom door hinges using screws removed in step 6 (Figure 9).
11. Place lower V-block into lower cabinet hinge with notch parallel to cabinet (Figure 10).

Top hinge and screws

Bottom hinge and screws

Insert top pin into bearing

Figure 9. Door Hinges

Insert and tighten hinge pin

Figure 11. Installing Door

Shelving Adjustment

See Figure 12.

CAUTION Completely empty shelf or

drawer before removing.

1. Open the door. Tilt the shelf and remove it from the unit

V-block parallel to cabinet

2. Reposition each bracket separately. Grasp the middle of the bracket, pull the front end up and out, then forward to remove it.

TOP VIEW

3. Place brackets at desired location and reinstall shelf(s).

Figure 10. Installing V-Block

12. Lift door assembly and insert top pin into bearing. Move door toward cabinet and align V-blocks (Figure 11).
Perlick BBRN — TOP VIEW diagram (page 8)
Fig. 2
13. Insert and tighten lower hinge pin to complete assembly.

Figure 12. Shelf Bracket

Page 9 of the Perlick BBRN user manual — Stainless Steel Care & Cleaning
Page 9 · click to enlarge
Page 9

DANGER Never attempt to repair or

the metal is passive and stainless. If the passive film of stainless steel has been broken, equipment starts to corrode and rust.

perform maintenance on the unit until the main electrical power to the unit has been disconnected!

There are three basic things which can break down stainless steel’s passive layer and allow corrosion to occur:

LED Light Replacement

(Figure 13).

  • Mechanical abrasion
  • Deposits and water
  • Chlorides
1. Open the door, or remove the upper drawer (see Removing Drawer, Figure 15).
2. Using a flat blade screwdriver, carefully pry off the lens cover.

Mechanical abrasion refers to the things that will scratch a steel surface. Steel pads, wire brushes and scrapers are prime examples.

3. Remove the two screws securing LED light to housing.

Water comes out of the faucet in varying degrees of hardness. Depending on what part of the country you live in, you may have hard or soft water. Hard water may leave spots. When allowed to sit, these deposits will break down the passive layer and rust stainless steel. Other deposits from food preparation must be promptly removed with an appropriate cleaning agent.

4. Unplug the LED from the wiring harness.
5. Plug new LED into harness and secure to housing using screws removed in step 2.
6. Snap LED cover into place.

Unplug LED Light Strip

Chlorides are found nearly everywhere. They are in water, food and table salt. Household and industrial cleaners are the worst offenders.

Preventing Stainless Steel Rust

Use the proper tools. Use non-abrasive tools to clean stainless steel products. Soft cloths and plastic scouring pads will not harm the steel’s passive layer.

#6-32 x 3/8” machine screw (Qty. 2)

Clean with polish lines. Some stainless steels come with visible polishing lines or “grain”. When visible lines are present, always scrub in a motion parallel to the lines. When the grain cannot be seen, play it safe and do not use a circular motion. Polish in a consistent straight pattern.

Figure 13. Interior LED Light

Stainless Steel Care & Cleaning

Contrary to popular belief, stainless steel is susceptible to rusting. Corrosion on metals is everywhere. It is recognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “active” because they actively corrode in a natural environment when their atoms combine with oxygen.

Use alkaline, alkaline chlorinated or non-chloride containing cleaners. While many traditional cleaners are loaded with chlorides, the industry is providing an ever-increasing choice on non- chloride cleaners. If you are not sure of chloride content in the cleaner being used, contact your cleaner supplier. If your present cleaner contains chlorides, ask your supplier if they have an alternative. Avoid cleaners containing quaternary salt; it also can attack stainless steel and cause pitting and rusting.

Stainless steel is a “passive” metal because it contains other metals like chromium, nickel and manganese that stabilize the atoms. Chromium provides an invisible passive film that covers the steel surface acting as a shield against corrosion. As long as the film is intact and not contaminated,

Show 4 more labels / short text on this page
Maintenance · LED Light Strip · Lens Cover · General
Page 10 of the Perlick BBRN user manual — Cleaning Cabinet Interior/Exterior
Page 10 · click to enlarge
Page 10

Keep food equipment clean. Use alkaline chlorinated or non-chloride cleaners at recommended strength. Clean frequently to avoid build-up of hard, stubborn stains. The single most likely cause of damage is chlorides in the water. Remember, adding heat to cleaners that contain chlorides dramatically increases their effect on stainless steel.

Glass panels may be cleaned using any standard glass cleaner available on the market.

To clean interior and exterior non-metallic surfaces and removable parts, wash with a mild solution of soap and lukewarm water with a little baking soda. Rinse and dry thoroughly. Avoid getting water on lights, controller and fan motors.

Cleaning the Condenser

Rinse, rinse, rinse! If chlorinated cleaners are used, immediately rinse and wipe equipment and supplies dry. The sooner you wipe standing water, especially when it contains cleaning agents, the better. After wiping equipment down, allow it to air dry. Oxygen helps maintain the stainless steel passive film.

The condenser (located behind front grille cover) should be cleaned every three (3) months. Use a soft bristle brush and vacuum to remove the dust and lint.

crushing the condenser fins or tubing. Failure to follow this procedure may damage the compressor and void the warranty.

Cleaning Cabinet Interior/Exterior

CAUTION NEVER use hydrochloric

acid (muriatic acid) on stainless steel. Do not use abrasive cleansers or cloths on any interior or exterior surfaces or removable parts.

Page 11 of the Perlick BBRN user manual — Recommended Cleaners for Specific Situations
Page 11 · click to enlarge
Page 11

Recommended Cleaners for Specific Situations

JobCleaning AgentComments Routine cleaning.Soap, ammonia, detergentApply with sponge or soft cloth. Fingerprints and smears.Areal 20, Lac-O-Nu, Lumin Wash, O’Ceder Cream PolishProvides barrier film to minimize fingerprints. Can be used on all finishes. Rub the surface with a cloth as directed on the package. Stubborn stains and discolorations.AllChem Concentrated Cleaner, Samae, Twinkle, Cameo Copper Cleaners, Grade FFF Italian Pumice Whiting, Steel Bright, Lumin Cleaner, Zud Restoro, Sta-Clean, Highlite Cooper’s Stainless Steel Cleaner or Revere Stainless Steel Cleaner.Apply with a damp sponge or cloth, then rinse with clear water and wipe dry. Old Dutch, Lighthouse Sunbrite, Wyandotte Bab-O, gold Dust, Sapollo, Bon Ami or Comet.For these household cleaners, rub with a damp cloth. They may contain chlorine bleaches so rinse thoroughly after use and wipe dry Liquid NuSteel or Dubois TempFor these products, rub the surface with a dry cloth using only a small amount of cleanser. Rinse with water and dry. Heat tint or heavy discoloration.Penny-Brite, Copper Brite, Paste NuSteel, Dubois Temp or TarniteRinse and rub onto surface with a dry cloth. Bar Keepers Friend, Revere Stainless Steel Cleaner, Allen Polish, Steel Bright Wyandotte Bab-O or Zud.When using these cleaners, apply with a damp sponge or cloth, rinse thoroughly and wipe dry. Tenacious deposits, rust, discoloration, industrial atmospheric stains.Oakite No. 33 Dilac, Texo NY, FlashKlenz Caddy Cleaner, Turco Scale 4368 or Permag 57.Use Swab and soak with a clean cloth. Let stand for 15 minutes or more according to directions on package then rinse and wipe dry. Rust discoloration or corrosion caused by cleaning agents containing hydrochloric (muriatic) acid or chlorine bleach3M Scotch Brite pad, type A Grade “Fine”Clean off the surface soil using cleaning methods above. Then rub discolored or corroded areas lightly with dry pad. Use of property names is intended only to indicate a type of cleaner and does not constitute an endorsement. Omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on the package. NOTE: Do not use steel wool or scouring pads to clean stainless steel.
Page 12 of the Perlick BBRN user manual — Before Calling For Service
Page 12 · click to enlarge
Page 12

Before Calling For Service

If the unit appears to be malfunctioning, read through the Operation section in this manual first. If the problem persists, check through this troubleshooting section. Locate the problem and refer to the cause and remedy before calling for service. The problem could be something that can be solved without a service call.

power to the unit has been disconnected!

ProblemCauseSolution No interior light.Rocker switch in Off position.Turn switch on. LED board inoperable.Contact your selling dealer. Light stays on when door is closed.Manual switch on.Turn manual switch off. Noisy operation.Soft sounds from compressor, fan motor and valves heard.Normal operation. LED Controller display is flashing .“P1”.Thermostat probe failure.Contact your selling dealer. LED Controller display is flashing “HA”.Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes.Make sure door is completely closed. Check door gasket seal. Replace if necessary. Check condenser and clean if necessary. Make sure louvered plate is unobstructed. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. Make sure interior light is off. Warm product placed in cabinet recently. Wait 24 hours for product to chill then recheck temperature. LED Controller display is flashing “LA”.Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes.Make sure door is completely closed. Check door gasket seal. Replace if necessary. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. LED Controller display is flashing “EE”.Controller has a data or memory failure.Reset both compartment presets. If problem persists, contact your Perlick Service Department. Unit is not running.No power to the unit. Condenser dirty.Home circuit breaker tripped. Reset circuit breaker. ON/OFF keypad is off. Turn on. Clean the condenser. Compartments are warmer than usual.Control preset not set properly. Light staying on. Condenser dirty or obstructed. Door is open or has been opened more frequently lately. Internal louvers and/or fan guard obstructed. Warm product placed in cabinet recently.Reset compartments presets. Turn manual light switch off. Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Make sure louvers and/or fan is not obstructed.

Troubleshooting

Page 13 of the Perlick BBRN user manual — For Product Service
Page 13 · click to enlarge
Page 13

System runs for long period of time.

Condenser dirty or obstructed. Door kept open for long time or opened more frequently. Warm product place in cabinet recently. Hot day and warm room temperature.

Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Normal for system to run more frequently.

Condensation forms inside the compartments.

High humidity and/or frequent door opening. Door not closing and sealing properly.

Normal operation.

Make sure door is closing properly. Check door seals and replace if necessary.

Condensation forms on outside of unit.

High humidity and/or frequent door opening. Door not closing and sealing properly.

Normal operation.

Make sure door is closing properly. Check door seals and replace if necessary. If condensation persists, contact your selling dealer.

For Product Information

For Replacement Parts and Accessories

  • Contact your selling dealer.
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a>
  • Call (800) 558-5592 for factory assistance on planning installation or product information.
  • Write to Perlick Corporation, Customer Service Department, 8300 West Good Hope Road, Milwaukee, WI 53223.
  • Email us at warrantyserv@<a href="http://perlick.com" rel="nofollow noopener" target="_blank">perlick.com</a>.
  • Use only genuine Perlick replacement parts and accessories. Genuine Perlick parts and accessories are designed to work correctly with Perlick products and offer superior service life. The use of non-Perlick parts can damage the unit and may void the warranty.
  • Check the model and serial number of your unit which is located on the right or left interior panel. Call your Perlick Factory Authorized Service Center.
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a> or call (800) 558-5592.

For Product Service

  • Check the model and serial number of your unit located on the label attached to the inside top of the cabinet.
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a> or call (800) 558-5592.

Problem Cause Solution

Page 14 of the Perlick BBRN user manual — For Product Information
Page 14 · click to enlarge
Page 14
Perlick BBRN — For Product Information diagram (page 14)
Fig. 3 · For Product Information
Page 15 of the Perlick BBRN user manual — For Product Information
Page 15 · click to enlarge
Page 15
Perlick BBRN — For Product Information diagram (page 15)
Fig. 4 · For Product Information
Page 16 of the Perlick BBRN user manual — For Product Information
Page 16 · click to enlarge
Page 16
Perlick BBRN — For Product Information diagram (page 16)
Fig. 5 · For Product Information
Page 17 of the Perlick BBRN user manual — For Product Information
Page 17 · click to enlarge
Page 17
Perlick BBRN — For Product Information diagram (page 17)
Fig. 6 · For Product Information
Page 18 of the Perlick BBRN user manual — For Product Information
Page 18 · click to enlarge
Page 18
Perlick BBRN — For Product Information diagram (page 18)
Fig. 7 · For Product Information
Page 19 of the Perlick BBRN user manual — For Product Information
Page 19 · click to enlarge
Page 19
Perlick BBRN — For Product Information diagram (page 19)
Fig. 8 · For Product Information
Page 20 of the Perlick BBRN user manual — METHOD OF SHIPMENT
Page 20 · click to enlarge
Page 20

The terms and conditions set forth below together with those appearing on the face of the Acknowledgement (the “Order”) constitute the complete and exclusive agreement between Perlick Corporation and the Buyer pertaining to the goods and/or services identified in the Order. If there is a discrepancy or conflict between any exhibit or supplement to the Order and these terms and conditions, these terms and conditions shall control. The Order is intended by Seller and Buyer to be the complete, exclusive, and final statement of their agreement. Any changes to an Order must be in writing and signed by Perlick and Buyer.

LOST and DAMAGED MERCHANDISE

THE RESPONSIBILITY OF THE PERLICK CORPORATION CEASES UPON ACCEPTANCE OF ITS PRODUCTS BY THE CARRIER. Any damage or loss sustained in shipment is the carrier’s responsibility. Before giving the carrier a clean receipt at time of delivery, make sure you receive every item on the bill and inspect every carton, crate and box for concealed damage, i.e., broken boards, crushed or punctured cartons, torn cardboard. IF ANY ITEMS ARE SHORT OR DAMAGED, DO NOT ACCEPT THE SHIPMENT UNLESS THE CARRIER MAKES A NOTATION OF THIS ON YOUR FREIGHT BILL. Then request an inspection. Do not destroy the packing materials. If their agent does not make an inspection within five days, advise the carrier via letter that you notified them regarding the matter and they have failed to act. You will need this letter to support your claim. Then file a claim for your loss. When you give the carrier a clean receipt, you accept the total responsibility for the shipment. UPS shipments are insured individually and UPS will replace all merchandise that is lost or damaged.

TERMS NET 30 DAYS

Payment by Visa, MasterCard, American Express or Discover card accepted or cash in advance unless prior accommodations have been made with our Credit Department. Please direct inquiries for detailed information to our Credit Manager. All sales, excise, or similar taxes required by law to be collected or paid by seller shall be in addition to prices quoted unless an appropriate Tax Exemption certificate is furnished. All goods are sold F.O.B. factory. Except for otherwise provided, Perlick will not be responsible for freight, transportation, insurance, shipping, storage, handling, demurrage or similar charges. Invoices are payable in full in thirty (30) days following the invoice‚s date of issuance. If by the terms of sale credit is extended, Perlick reserves the right to revoke such credit if buyer fails to pay for any products when due and may demand payment prior to the commencement of any further shipment.

RETURN OF MERCHANDISE

Do not return any merchandise without our approval. Merchandise returned without a return merchandise authorization number will not be accepted at Perlick. Used, discontinued, and certain custom made items cannot be returned for credit. These custom items include non-catalog products (specials) as well as custom assembled catalog products. Catalog items are designated as non-returnable on the price list page on which they appear. Items returned must be in new condition and packaged in their original carton or crate. Freight charges must be prepaid on all return shipments.

WAIVER

Any waiver of strict compliance with the provisions of an Order must be in writing. No such waiver shall be construed as a waiver of any other term or condition except as provided in writing, nor as a waiver of any subsequent breach of the same term or condition.

When a return is authorized, a credit may be allowed pending an examination of the returned goods. The amount of the restocking charge will depend on the condition of the equipment. The minimum restocking charge for glass washers, bottle coolers, frosters, direct draws, cooler series back bars and accessory parts is 20%. The minimum restocking charge for custom series cabinets is 50%. The minimum restocking

METHOD OF SHIPMENT

All shipments are carefully packed and labeled. Crates, boxes and cartons used are of approved weight and strength. Freight rates are based upon 100 pound minimum.

Warranty

Page 21 of the Perlick BBRN user manual — ONE YEAR PARTS WARRANTY
Page 21 · click to enlarge
Page 21

charge for un-assembled, freestanding underbar stainless steel modules is 20%. Assembled under bar modules are considered custom products and are not returnable for credit. The restocking charge on the item returned is either a percentage of the value of the item or $35.00, whichever is greater.

ONE YEAR LABOR WARRANTY

In addition to Perlick’s one year parts warranty and five year compressor warranty, ALL PERLICK REFRIGERATION SYSTEMS are offered with a one year labor warranty at no extra charge. Perlick’s one year labor warranty provides that Perlick will pay for the cost of any labor to replace any defective part for up to one year after installation, subject to the following terms and conditions:

ONE YEAR PARTS WARRANTY

Perlick products are guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, when adjudged defective upon inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs associated with replacement, including freight, labor and/or loss of sales, are the responsibility of the user..

(A) Parts returned to Perlick shall be returned

freight prepaid and shall be identified with Perlick’s serial number and return authorization number.

(B) Improper operation due to voltage variances,

inadequate wiring and physical damage is the responsibility of the purchaser. They are not manufacturing defects.

(C) Condenser coils shall be cleaned regularly.

Failure to provide an adequate flow of cooling air will void this warranty.

(D) Factory-specified maintenance and installation

will be provided by the selling dealer who shall also be responsible for the installation and set- up of these products in accordance with local plumbing, refrigeration and electrical codes.

Perlick’s one year labor policy applies to the United States and Canada. IT DOES NOT APPLY TO REFRIGERATION SYSTEMS ADDED BY OTHERS (remote systems) or any part which has been subject to misuse, neglect, alteration, accident, or to any damage caused by transportation, flood, fire or other acts of God.

Page 22 of the Perlick BBRN user manual — ONE YEAR LABOR WARRANTY
Page 22 · click to enlarge
Page 22
Page 23 of the Perlick BBRN user manual — ONE YEAR LABOR WARRANTY
Page 23 · click to enlarge
Page 23
Page 24 of the Perlick BBRN user manual — ONE YEAR LABOR WARRANTY
Page 24 · click to enlarge
Page 24
  • 8300 West Good Hope Road
  • Milwaukee, WI 53223
  • Toll Free 800.558.5592
  • Fax 414.353.7069
  • <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a>
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No interior light.Rocker switch in Off position.Turn switch on. p.12
No interior light.LED board inoperable.Contact your selling dealer. p.12
Light stays on when door is closed.Manual switch on.Turn manual switch off. p.12
Noisy operation.Soft sounds from compressor, fan motor and valves heard.Normal operation. p.12
LED Controller display is flashing .“P1”.Thermostat probe failure.Contact your selling dealer. p.12
LED Controller display is flashing “HA”.Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes.Make sure door is completely closed. Check door gasket seal. Replace if necessary. Check condenser and clean if necessary. Make sure louvered plate is unobstructed. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. Make sure interior light is off. Warm product placed in cabinet recently. Wait 24 hours for product to chill then recheck temperature. p.12
LED Controller display is flashing “LA”.Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes.Make sure door is completely closed. Check door gasket seal. Replace if necessary. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. p.12
LED Controller display is flashing “EE”.Controller has a data or memory failure.Reset both compartment presets. If problem persists, contact your Perlick Service Department. p.12
Unit is not running.No power to the unit. Condenser dirty.Home circuit breaker tripped. Reset circuit breaker. ON/OFF keypad is off. Turn on. Clean the condenser. p.12
Compartments are warmer than usual.Control preset not set properly. Light staying on. Condenser dirty or obstructed. Door is open or has been opened more frequently lately. Internal louvers and/or fan guard obstructed. Warm product placed in cabinet recently.Reset compartments presets. Turn manual light switch off. Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Make sure louvers and/or fan is not obstructed. p.12
System runs for long period of time.Condenser dirty or obstructed. Door kept open for long time or opened more frequently. Warm product place in cabinet recently. Hot day and warm room temperature.Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Normal for system to run more frequently. p.13
Condensation forms inside the compartments.High humidity and/or frequent door opening. Door not closing and sealing properly.Normal operation. Make sure door is closing properly. Check door seals and replace if necessary. p.13
Condensation forms on outside of unit.High humidity and/or frequent door opening. Door not closing and sealing properly.Normal operation. Make sure door is closing properly. Check door seals and replace if necessary. If condensation persists, contact your selling dealer. p.13

Ask about the Perlick BBRN

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick BBRN

Be the first to ask — other owners or our team will answer.

Original document

Perlick BBRN manual PDF

24 pages·3.2 MB·Refrigerator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…