Commercial Back Bar
Models BBRN & BBSN Series

Form No. 2322013
Model BBRN40 Shown

General Information 2 Safety 2 Prior To Installation 3 Installation 4 Operation 5 Adjustments 6 Maintenance 9 Troubleshooting 12 Dimensions 14 Wiring Diagrams 17 Warranty 20
Warranty
Congratulations on your purchase of a Perlick commercial back bar product. This manual has been prepared to assist you in the installation of your cabinet and to acquaint you with its operation and maintenance.
To register your product, visit our web site at www.perlick.com Click on “Commercial”, then “Service”. Click on the link “Warranty Registration Form”. You must complete and submit this form or the installation date will revert back to the ship date.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval.
Please record the purchase date and the dealer’s name, address and telephone number below.
Model Number: Serial Number: Purchase Date: Dealer Name & Address Phone Number
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING an CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit.
cause serious injury or death if precautions are not followed.
minor injury or product damage may occur if precautions are not followed.
result in serious injury or death if precautions are not followed.
All plumbing and electrical work must be performed by a qualified technician and
conform to all applicable state and local codes.
Table of Contents · General Information · Safety

bottom, of the unit. Both drain ports come plugged from the factory and can be removed if needed. NOTE: Remote units require evaporator condensate to be plumbed to an external drain. Electrical The cabinet must be connected to a separately fused power source (see Electrical Specification Plate affixed to unit) in accordance with National and Local electrical codes.
Remove all crating material. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit.
sleeve covering the unit. Cutting may result in damage to the exterior of the cabinet. Failure to follow this procedure may damage the compressor and void warranty. 1. Uncrate the unit on flat, level surface. Remove the cardboard sleeve by removing the banding securing the sleeve to the shipping base. Carefully lift the cardboard sleeve up over the top of the unit. 2. Carefully lift unit off the base and onto a hand truck or dolly. Make sure unit is balanced on transporting device using soft, flexible strapping. Protect unit surfaces with cloth material where strapping contacts unit.
Self-contained Perlick units come equipped with a NEMA 5-15P 90° plug with an 8’ cord extending beyond the rear of the cabinet. The electrical outlet must be flush with, or recessed into, the wall surface.
back or sides, place unit upright and allow minimum of 24 hours before connecting power. Failure to follow this procedure may damage the compressor and void the warranty.
shelving or door handles or damage to the unit could occur.
the equipment on any other power source than that listed on the Electrical Specification Plate attached to the unit.
i n j u r y, t w o p e o p l e minimum required to lift the unit. Larger units may require additional personnel. 3. Before moving unit, secure door(s) to unit with tape to prevent from opening. 4. Carefully move unit to installation site and place in front of opening.
b e p r o t e c t e d w i t h appropriate material to avoid damage from moving the unit. Plumbing
fitting or damage to the threads could occur. Condensate from the cooling coil is automatically evaporated from the condensate pan located in the condensing unit housing on self-contained models. Each unit is equipped with a floor drain located in the right rear corner of the cabinet. The drain can be plumbed to an external floor drain by connecting to the 3/4” NPT thread connection on the side, or the 1” NPS thread connection out the
electrical guidelines may result in possible death or serious injury, fire, or loss of property.
Prior To Installation

Installing the Unit
back or sides, place unit upright and allow minimum of 24 hours before connecting power.
the unit is level with the surrounding finished floor. Protect a finished floor with plywood, cardboard or some other suitable material before moving the unit into place. Failure to do this may result in damage to the floor.
For installation in areas of high humidity, a 115- volt electric condensate pan can be installed underneath the cabinet to collect and evaporate the condensate from the cabinet evaporator. A 6’ 3-prong plug is included. A separate circuit should be provided for the heater. The kit can be used only on cabinets equipped with 4” minimum legs; it cannot be used on units equipped with platform or base plate kits. Follow instructions supplied with the kit.
Once the unit is secured in place, install the base plate brackets to the cabinet bottom in the holes provided. Attach base plate to brackets. Refer to the installation instructions included with the Base Plate Kit.
Refer to the instructions included with the Casters or Legs Kit.
Installation

For units without casters or legs, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor (Figure 1).
Bead Silicon Sealer (RTV)
Figure 1. Sealing Cabinet to Floor
Refer to the instructions included with the Faucet and Dispensing Head Kit.
The cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of approximately 38° F.
Allow a minimum of 24 hours for ambient temperature product to reach storage temperature.
The following factors affect the internal temperature of the unit:
Draft beer should be stored at a temperature between 32° – 38° F. The most common cause of dispensing problems is improper temperature; beer will foam at warmer temperatures.
Beer will freeze at temperatures lower than 30° F. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.
The following chart shows how temperature affects beer:
The unit is equipped with an interior LED light in the upper front of the unit just inside the door or drawer. The light illuminates when the manual rocker light switch is turned on. The rocker light switch is located behind the LED light on the inside of the frame on either the right or left side (same side as the compressor).
Cabinet · Floor · Operation

To change the Setpoint:
Figure 2. Digital Temperature Controller
Hinge brackets and mounting screws
Hinge brackets and mounting screws
Pull door to the side then lower door
Figure 4. Hinge Removal
Figure 3. Door Removal

Hinge brackets and mounting screws
Hinge brackets and mounting screws
Corner screws need not be removed to remove front panel
Figure 5. Hinge Installation
Figure 7. Removing Front Panel
Hinge brackets and mounting screws
Bearing in door top hinge bracket
Figure 6. Door Brackets
Figure 8. Bearing and V-Block

Top hinge and screws
Bottom hinge and screws
Insert top pin into bearing
Figure 9. Door Hinges
Insert and tighten hinge pin
Figure 11. Installing Door
See Figure 12.
drawer before removing.
V-block parallel to cabinet
Figure 10. Installing V-Block

Figure 12. Shelf Bracket

the metal is passive and stainless. If the passive film of stainless steel has been broken, equipment starts to corrode and rust.
perform maintenance on the unit until the main electrical power to the unit has been disconnected!
There are three basic things which can break down stainless steel’s passive layer and allow corrosion to occur:
(Figure 13).
Mechanical abrasion refers to the things that will scratch a steel surface. Steel pads, wire brushes and scrapers are prime examples.
Water comes out of the faucet in varying degrees of hardness. Depending on what part of the country you live in, you may have hard or soft water. Hard water may leave spots. When allowed to sit, these deposits will break down the passive layer and rust stainless steel. Other deposits from food preparation must be promptly removed with an appropriate cleaning agent.
Unplug LED Light Strip
Chlorides are found nearly everywhere. They are in water, food and table salt. Household and industrial cleaners are the worst offenders.
Preventing Stainless Steel Rust
Use the proper tools. Use non-abrasive tools to clean stainless steel products. Soft cloths and plastic scouring pads will not harm the steel’s passive layer.
#6-32 x 3/8” machine screw (Qty. 2)
Clean with polish lines. Some stainless steels come with visible polishing lines or “grain”. When visible lines are present, always scrub in a motion parallel to the lines. When the grain cannot be seen, play it safe and do not use a circular motion. Polish in a consistent straight pattern.
Figure 13. Interior LED Light
Contrary to popular belief, stainless steel is susceptible to rusting. Corrosion on metals is everywhere. It is recognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “active” because they actively corrode in a natural environment when their atoms combine with oxygen.
Use alkaline, alkaline chlorinated or non-chloride containing cleaners. While many traditional cleaners are loaded with chlorides, the industry is providing an ever-increasing choice on non- chloride cleaners. If you are not sure of chloride content in the cleaner being used, contact your cleaner supplier. If your present cleaner contains chlorides, ask your supplier if they have an alternative. Avoid cleaners containing quaternary salt; it also can attack stainless steel and cause pitting and rusting.
Stainless steel is a “passive” metal because it contains other metals like chromium, nickel and manganese that stabilize the atoms. Chromium provides an invisible passive film that covers the steel surface acting as a shield against corrosion. As long as the film is intact and not contaminated,

Keep food equipment clean. Use alkaline chlorinated or non-chloride cleaners at recommended strength. Clean frequently to avoid build-up of hard, stubborn stains. The single most likely cause of damage is chlorides in the water. Remember, adding heat to cleaners that contain chlorides dramatically increases their effect on stainless steel.
Glass panels may be cleaned using any standard glass cleaner available on the market.
To clean interior and exterior non-metallic surfaces and removable parts, wash with a mild solution of soap and lukewarm water with a little baking soda. Rinse and dry thoroughly. Avoid getting water on lights, controller and fan motors.
Rinse, rinse, rinse! If chlorinated cleaners are used, immediately rinse and wipe equipment and supplies dry. The sooner you wipe standing water, especially when it contains cleaning agents, the better. After wiping equipment down, allow it to air dry. Oxygen helps maintain the stainless steel passive film.
The condenser (located behind front grille cover) should be cleaned every three (3) months. Use a soft bristle brush and vacuum to remove the dust and lint.
crushing the condenser fins or tubing. Failure to follow this procedure may damage the compressor and void the warranty.
CAUTION NEVER use hydrochloric
acid (muriatic acid) on stainless steel. Do not use abrasive cleansers or cloths on any interior or exterior surfaces or removable parts.


If the unit appears to be malfunctioning, read through the Operation section in this manual first. If the problem persists, check through this troubleshooting section. Locate the problem and refer to the cause and remedy before calling for service. The problem could be something that can be solved without a service call.
power to the unit has been disconnected!
Troubleshooting

System runs for long period of time.
Condenser dirty or obstructed. Door kept open for long time or opened more frequently. Warm product place in cabinet recently. Hot day and warm room temperature.
Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Normal for system to run more frequently.
Condensation forms inside the compartments.
High humidity and/or frequent door opening. Door not closing and sealing properly.
Normal operation.
Make sure door is closing properly. Check door seals and replace if necessary.
Condensation forms on outside of unit.
High humidity and/or frequent door opening. Door not closing and sealing properly.
Normal operation.
Make sure door is closing properly. Check door seals and replace if necessary. If condensation persists, contact your selling dealer.
For Replacement Parts and Accessories
Problem Cause Solution













The terms and conditions set forth below together with those appearing on the face of the Acknowledgement (the “Order”) constitute the complete and exclusive agreement between Perlick Corporation and the Buyer pertaining to the goods and/or services identified in the Order. If there is a discrepancy or conflict between any exhibit or supplement to the Order and these terms and conditions, these terms and conditions shall control. The Order is intended by Seller and Buyer to be the complete, exclusive, and final statement of their agreement. Any changes to an Order must be in writing and signed by Perlick and Buyer.
THE RESPONSIBILITY OF THE PERLICK CORPORATION CEASES UPON ACCEPTANCE OF ITS PRODUCTS BY THE CARRIER. Any damage or loss sustained in shipment is the carrier’s responsibility. Before giving the carrier a clean receipt at time of delivery, make sure you receive every item on the bill and inspect every carton, crate and box for concealed damage, i.e., broken boards, crushed or punctured cartons, torn cardboard. IF ANY ITEMS ARE SHORT OR DAMAGED, DO NOT ACCEPT THE SHIPMENT UNLESS THE CARRIER MAKES A NOTATION OF THIS ON YOUR FREIGHT BILL. Then request an inspection. Do not destroy the packing materials. If their agent does not make an inspection within five days, advise the carrier via letter that you notified them regarding the matter and they have failed to act. You will need this letter to support your claim. Then file a claim for your loss. When you give the carrier a clean receipt, you accept the total responsibility for the shipment. UPS shipments are insured individually and UPS will replace all merchandise that is lost or damaged.
Payment by Visa, MasterCard, American Express or Discover card accepted or cash in advance unless prior accommodations have been made with our Credit Department. Please direct inquiries for detailed information to our Credit Manager. All sales, excise, or similar taxes required by law to be collected or paid by seller shall be in addition to prices quoted unless an appropriate Tax Exemption certificate is furnished. All goods are sold F.O.B. factory. Except for otherwise provided, Perlick will not be responsible for freight, transportation, insurance, shipping, storage, handling, demurrage or similar charges. Invoices are payable in full in thirty (30) days following the invoice‚s date of issuance. If by the terms of sale credit is extended, Perlick reserves the right to revoke such credit if buyer fails to pay for any products when due and may demand payment prior to the commencement of any further shipment.
Do not return any merchandise without our approval. Merchandise returned without a return merchandise authorization number will not be accepted at Perlick. Used, discontinued, and certain custom made items cannot be returned for credit. These custom items include non-catalog products (specials) as well as custom assembled catalog products. Catalog items are designated as non-returnable on the price list page on which they appear. Items returned must be in new condition and packaged in their original carton or crate. Freight charges must be prepaid on all return shipments.
Any waiver of strict compliance with the provisions of an Order must be in writing. No such waiver shall be construed as a waiver of any other term or condition except as provided in writing, nor as a waiver of any subsequent breach of the same term or condition.
When a return is authorized, a credit may be allowed pending an examination of the returned goods. The amount of the restocking charge will depend on the condition of the equipment. The minimum restocking charge for glass washers, bottle coolers, frosters, direct draws, cooler series back bars and accessory parts is 20%. The minimum restocking charge for custom series cabinets is 50%. The minimum restocking
All shipments are carefully packed and labeled. Crates, boxes and cartons used are of approved weight and strength. Freight rates are based upon 100 pound minimum.
Warranty

charge for un-assembled, freestanding underbar stainless steel modules is 20%. Assembled under bar modules are considered custom products and are not returnable for credit. The restocking charge on the item returned is either a percentage of the value of the item or $35.00, whichever is greater.
In addition to Perlick’s one year parts warranty and five year compressor warranty, ALL PERLICK REFRIGERATION SYSTEMS are offered with a one year labor warranty at no extra charge. Perlick’s one year labor warranty provides that Perlick will pay for the cost of any labor to replace any defective part for up to one year after installation, subject to the following terms and conditions:
Perlick products are guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, when adjudged defective upon inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs associated with replacement, including freight, labor and/or loss of sales, are the responsibility of the user..
(A) Parts returned to Perlick shall be returned
freight prepaid and shall be identified with Perlick’s serial number and return authorization number.
(B) Improper operation due to voltage variances,
inadequate wiring and physical damage is the responsibility of the purchaser. They are not manufacturing defects.
(C) Condenser coils shall be cleaned regularly.
Failure to provide an adequate flow of cooling air will void this warranty.
(D) Factory-specified maintenance and installation
will be provided by the selling dealer who shall also be responsible for the installation and set- up of these products in accordance with local plumbing, refrigeration and electrical codes.
Perlick’s one year labor policy applies to the United States and Canada. IT DOES NOT APPLY TO REFRIGERATION SYSTEMS ADDED BY OTHERS (remote systems) or any part which has been subject to misuse, neglect, alteration, accident, or to any damage caused by transportation, flood, fire or other acts of God.



Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No interior light. | Rocker switch in Off position. | Turn switch on. | p.12 |
| No interior light. | LED board inoperable. | Contact your selling dealer. | p.12 |
| Light stays on when door is closed. | Manual switch on. | Turn manual switch off. | p.12 |
| Noisy operation. | Soft sounds from compressor, fan motor and valves heard. | Normal operation. | p.12 |
| LED Controller display is flashing .“P1”. | Thermostat probe failure. | Contact your selling dealer. | p.12 |
| LED Controller display is flashing “HA”. | Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes. | Make sure door is completely closed. Check door gasket seal. Replace if necessary. Check condenser and clean if necessary. Make sure louvered plate is unobstructed. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. Make sure interior light is off. Warm product placed in cabinet recently. Wait 24 hours for product to chill then recheck temperature. | p.12 |
| LED Controller display is flashing “LA”. | Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes. | Make sure door is completely closed. Check door gasket seal. Replace if necessary. If surrounding ambient temperature has changed dramatically recently, compartment temperature may be affected. | p.12 |
| LED Controller display is flashing “EE”. | Controller has a data or memory failure. | Reset both compartment presets. If problem persists, contact your Perlick Service Department. | p.12 |
| Unit is not running. | No power to the unit. Condenser dirty. | Home circuit breaker tripped. Reset circuit breaker. ON/OFF keypad is off. Turn on. Clean the condenser. | p.12 |
| Compartments are warmer than usual. | Control preset not set properly. Light staying on. Condenser dirty or obstructed. Door is open or has been opened more frequently lately. Internal louvers and/or fan guard obstructed. Warm product placed in cabinet recently. | Reset compartments presets. Turn manual light switch off. Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Make sure louvers and/or fan is not obstructed. | p.12 |
| System runs for long period of time. | Condenser dirty or obstructed. Door kept open for long time or opened more frequently. Warm product place in cabinet recently. Hot day and warm room temperature. | Clean condenser and clear obstruction. Wait 24 hours and recheck temperature. Reset preset temperature if necessary. Normal for system to run more frequently. | p.13 |
| Condensation forms inside the compartments. | High humidity and/or frequent door opening. Door not closing and sealing properly. | Normal operation. Make sure door is closing properly. Check door seals and replace if necessary. | p.13 |
| Condensation forms on outside of unit. | High humidity and/or frequent door opening. Door not closing and sealing properly. | Normal operation. Make sure door is closing properly. Check door seals and replace if necessary. If condensation persists, contact your selling dealer. | p.13 |