EN
Perlick logo
Official user manual

Perlick HC24

12 pages·1.2 MB·Refrigerator·PDF·ENDEFRITNLJA
Perlick HC24
Table of Contents 17 sections Use and Care Guide All Models · HP15 HP24 HP48 HC24 HA24 HH24 · TABLE OF CONTENTS · PERLICK RESIDENTIAL PRODUCTS WARRANTY · … ShowHide
Page 1 of the Perlick HC24 user manual — HP15 HP24 HP48 HC24 HA24 HH24
Page 1 · click to enlarge
Page 1

Use and Care Guide All Models

HP15 HP24 HP48 HC24 HA24 HH24

15” SIGNATURE SERIES 24” SIGNATURE SERIES 48” SIGNATURE SERIES C-SERIES ADA-COMPLIANT SERIES SHALLOW-DEPTH SERIES

Perlick HC24 — HP15 HP24 HP48 HC24 HA24 HH24 diagram (page 1)
Fig. 1
Perlick HC24 — HP15 HP24 HP48 HC24 HA24 HH24 diagram (page 1)
Fig. 2

Form No. Z2344 Rev. 04.01.2014

Page 3 of the Perlick HC24 user manual — OTHER TERMS AND CONDITIONS:
Page 3 · click to enlarge
Page 3

REMEDY:

This Warranty does not apply to:

Perlick will provide the parts and labor necessary to repair or replace (at Perlick’s option) any parts proven to be defective in material or workmanship during the Basic Warranty Period. Perlick will provide the replacement parts, but not the labor, for any parts of the hermetically sealed refrigeration system proven to be defective in materials or workmanship during the Extended Warranty Period. The cost of freight to ship the replacement parts will be paid by Perlick. Replacement parts are warranted for the remainder of the original warranty period, or ninety (90) days, whichever is longer.

  • Damage to Products occurring during transportation.
  • Products that are used in a manner that is not normal residential or light commercial use.
  • Products that are: improperly installed; misused or abused; operated with low voltage; wired in a manner not conforming to electrical codes; not properly operated in accordance with Perlick’s instructions; not cleaned or maintained in accordance with Perlick’s instructions; modified; or damaged by lightning or other acts of nature.
  • Consumable items such as light bulbs.
  • Cosmetic damage.

REGISTRATION:

  • Adjustments to controls, door reversal, cleaning the condenser or other routine maintenance.

Your Perlick product can be registered via the online Warranty Registration form at http://www.perlick com/residential-products/service-support/warranty- registration/.

  • Products for which the original proof of purchase, delivery date or serial number cannot be verified.
  • Products for which the defective parts are not returned for inspection if requested by Perlick.

OTHER TERMS AND CONDITIONS:

This Warranty applies only to products installed in the fifty states of the United States, the District of Columbia and the ten provinces of Canada.

  • Damage to other property caused by the products, including but not limited to loss of food due to spoilage and damage caused by water leakage.

To obtain the warranty coverage described in this Warranty, Perlick or its authorized distributor or dealer must receive written notice of the warranty claim within the applicable warranty period. To receive parts and/or service and the name and telephone number of the nearest Perlick authorized service representative, please contact your Perlick dealer or distributor, or Perlick’s Customer Service Department by writing to it at Perlick Corporation, Attn: Customer Service Department, 8300 West Good Hope Road, Milwaukee, Wisconsin 53223; or by calling Perlick’s Customer Service Department at 800-558-5592; or by e-mailing Perlick’s Customer Service Department at warrantyserv@perlick.com. In addition, you can notify Perlick of a warranty claim by visiting Perlick’s website at http://www.perlick.com/residential-products/service- support/ and filling out and submitting the Technical Service Request form that appears there.

THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; PROVIDED HOWEVER, THAT TO THE EXTENT REQUIRED BY LAW, IMPLIED WARRANTIES ARE INCLUDED BUT DO NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY FIRST SET ABOVE.

PERLICK’S SOLE LIABILITY AND YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY ARE SET FORTH IN THE PARAGRAPH ENTITLED “REMEDY” SET FORTH ABOVE.

PERLICK SHALL HAVE NO LIABILITY WHATSOEVER FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING FROM THE SALE, USE OR INSTALLATION OF THE PRODUCT OR FROM ANY OTHER CAUSES WHATSOEVER, WHETHER BASED ON WARRANTY (EXPRESS OR IMPLIED) OR OTHERWISE BASED ON CONTRACT, TORT OR ANY OTHER THEORY OF LIABILITY. IN NO EVENT SHALL PERLICK’S LIABILITY WITH RESPECT TO A PRODUCT EXCEED THE PURCHASE PRICE OF THE PRODUCT.

All service provided by Perlick under this Warranty must be performed by Perlick’s authorized service representatives, unless otherwise specified by Perlick in writing. Service will be provided during normal business hours.

Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.

This Warranty applies only to the original retail purchaser of the Perlick product, and may not be assigned or transferred.

Page 4 of the Perlick HC24 user manual — OPERATION
Page 4 · click to enlarge
Page 4

SAFETY PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING and CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit.

LOADING PRODUCT Before storing perishables, turn unit on and allow it to operate for a minimum of 24 hours to allow temperatures to stabilize.

When loading items into the unit, do not block internal louvers and fan guard openings or performance will be decreased.

DANGER

Indicates a hazard that WILL result in serious injury or death if precautions are not followed.

CHECKING PRODUCT TEMPERATURE 1). To accurately check the temperature of product stored in the refrigerated compartment, insert an accurate thermometer into a plastic unbreakable bottle, partially filled with water. Tighten bottle cap securely.

WARNING

Indicates a hazard MAY cause serious injury or death if precautions are not followed.

2). Place the bottle in the desired area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. Adjust the temperature accordingly using the following procedures:

CAUTION

Indicates a hazard where minor injury or product damage may occur if precautions are not followed.

DIGITAL TEMPERATURE CONTROL Signature Series Models

OPERATION

Perlick HC24 — OPERATION diagram (page 4)
Fig. 3

MASTER SWITCH Signature Series products come equipped with a master power switch located behind the louvered toe kick. Remove the toe kick to turn power on or off to the unit.

INTERIOR LIGHT Door units are equipped with an interior light that illuminate when the door is opened. The cabinet also comes equipped with a manual light switch for displaying the products through a glass door. For Signature Series (HP) models, it is located in front of the control cradle. For C-Series (HC), ADA-Compliant (HA) and Shallow-Depth (HH) models, this is located on the back wall left of the light.

Figure 1. Digital Temperature Controller

Perlick Signature Series units come standard with state- of-the-art digital control. Please note there are two sets of instructions; one for 24” Signature Series Dual-Zone models, and another set for 15”, 24” Single-Zone, and 48” Signature Series models.

Programming Button Definitions:

Always ensure that the manual light switch is in the OFF position before closing a solid wood or stainless steel door. If manual light switch is left on for an extended period of time, it may increase the cabinet temperature, and cause the refrigeration system to run harder.

DEFROST button (melting snowflake)

Show 4 more labels / short text on this page
SET button · UP arrow · DOWN arrow · ON/OFF button
Page 5 of the Perlick HC24 user manual — DANGER
Page 5 · click to enlarge
Page 5

Signature Series Dual-Zone Control Instructions Upper Compartment: To view the upper compartment temperature, press and release the DEFROST button (melting snowflake).

Signature Series 15”, 24” Single-Zone, and 48” , C-Series, ADA Freezer Control Instructions

To Set Target Temperature Press and release the SET button. Display will show the current temperature setpoint.

Lower Compartment: Display reading always shows the lower compartment temperature.

To Change Setpoint Temperature

1. Press and hold the SET button until the display shows the current setpoint temperature with the “F” flashing.

Setpoint Display: Press and release the SET button; display will read St1. Press SET again and the LOWER compartment setpoint will be displayed.

2. Use the UP and DOWN arrow button to scroll to the desired temperature.

To Start A Manual Defrost (Freezer Models Only) Press the DEFROST button (melting sowflake)

Press SET again; the display will read St2. Press SET again and the UPPER compartment temperature will be displayed.

To Set Maximum Stored Temperature Press the UP arrow button to see the maximum stored temperature. To reset the maximum stored temperature, while displayed, press and hold the SET button until ‘rst’ flashes in the display.

Changing the Lower Compartment Temperature:

1. Press and hold the SET button until the display shows St1 with”F” flashing.
2. Press SET again to display the upper compartment’s current temperature (“F” will continue to flash).

To Set Minimum Stored Temperature Press the DOWN arrow button to see the minimum stored temperature. To reset the minimum stored temperature, while displayed, press and hold the SET button until ‘rst’ flashes in the display.

3. Use the UP or DOWN arrow key to scroll to the desired temperature. The controller will memorize the new temperature.

On/Off Press the ON/OFF button to turn the unit on or off.

Changing the Upper Compartment Temperature:

1. Press and hold the SET button until the display shows St1 with”F” flashing. Press the DOWN arrow once; the display will read St2,

Key Combinations:

2. Press SET again to display the upper compartment’s current temperature (“F” will continue to flash).

+ Press the UP and DOWN arrow buttons to lock and unlock the keyboard

3. Use the UP or DOWN arrow key to scroll to the desired temperature. The controller will memorize the new temperature.

+ Press the SET and DOWN arrow buttons simultaneously to enter programming mode.

+ Press the SET and UP arrow buttons simultaneously to return to room temperature display. NOTE: Dependent on the model and configuration, the controllers have been programmed to only allow a temperature adjustment within a specified range. See the chart on page 6 for the specified range allowed for your unit.

Signature Series – Dual-Zone Units ModelFactory Temperature Setpoint Lower/UpperRange (F) HP24D51°F / 62°F40° - 68° / 40° - 68°

Dual-Zone Temperature Scale To change F to C, press and hold the down arrow for 3 seconds.

Page 6 of the Perlick HC24 user manual — DANGER
Page 6 · click to enlarge
Page 6
Perlick HC24 — DANGER diagram (page 6)
Fig. 4
Signature Series – HP15 Models ModelMin Temp SetMax Temp SetFactory Temp Setpoint HP15R30° F42° F38° F HP15B30° F48° F42° F HP15W40° F68° F45° F HP15T30° F42° F38° F Signature Series – HP24 Models ModelMin Temp SetMax Temp SetFactory Temp Setpoint HP24R30° F42° F38° F HP24F-10° F10° F0° F HP24B30° F48° F42° F HP24W40° F68° F45° F HP24T30° F42° F38° F Signature Series – HP48 Models ModelMin Temp SetMax Temp SetFactory Temp Setpoint HP48WO40° F68° F45° F HP48WW40° F68° F45° F C-Series Models ModelMin Temp SetMax Temp SetFactory Temp Setpoint HC24R30° F42° F38° F HC24BB30° F48° F42° F HC24WB40° F68° F55° F ADA-Compliant Series ModelMin Temp SetMax Temp SetFactory Temp Setpoint HA24FB-10°100° F

DIAL TEMPERATURE CONTROL ADA-Compliant & Shallow-Depth Models (Excludes ADA Freezer - HA24F models use digital controller found on page 5)

Use a straight slot screwdriver to adjust the dial temperature control. The control is located at the top rear panel of the cabinet. Approximate temperature ranges are as follows:

ADA-Compliant Series ModelFactory Temp Setpoint HA24RB38° F HA24BB42° F HA24WB55° F Shallow-Depth Series ModelFactory Temp Setpoint HH24RS38° F HH24BS42° F HH24WS55° F

LED Functions The following table describes LED functions

Adjust the temperature as follows:

LEDModeFunction ONCompressor is on FlashingAnti-short cycle delay is on ONDefrost is on ONAlarm is on FlashingYou are in the process of programming the unit
Perlick HC24 — DANGER diagram (page 6)
Fig. 5

Colder Temperature: Turn the adjusting screw clockwise (to the right).

Warmer Temperature: Turn the adjusting screw counterclockwise (to the left).

Temperature Control OFF: Turn the adjusting screw completely counterclockwise to the OFF position until a click is heard.

Page 7 of the Perlick HC24 user manual — CAUTION
Page 7 · click to enlarge
Page 7

MAINTENANCE

Spring Start-Up This process should occur after the daily low temperatures is below the temperatures stated below: Freezer models: 32° F Refrigerator models: 38° F Beverage Center: 42° F Wine Reserve: 45° F

SEASONAL MAINTENANCE FOR UL-APPROVED OUTDOOR MODELS

Winterizing This process should occur when the daily low temperatures is at or below the temperatures stated below: Freezer models: 32° F Refrigerator models: 38° F Beverage Center: 42° F Wine Reserve: 45° F

1. Remove the grille.
2. Check the condensing unit to ensure it is clear of loose debris, and clean as necessary with a vacuum cleaner.
3. Reattach front grille to the unit.
4. Clean the interior of the unit using stainless steel cleaner and polish (see page 9).

It is best to winterize your unit before the low temperatures listed above.

5. Clean the exterior of the unit using stainless steel cleaner and polish (see page 9).
1. Turn the unit to OFF position by pressing the OFF button on the controller. The controller displays the word “OFF” and, for Signature Series models, turn the master switch located behind the grille off (if the power cord is accessible, unplug the power cord. If not, turn off the circuit breaker to the electrical receptacle the cabinet is plugged into). For C-Series units, unplug or turn off the circuit breaker.
6. Plug the unit into the electrical receptacle or turn on the circuit breaker.
7. Turn on the master switch located behind the grille if model is Signature Series. Press the OFF button one time to turn the unit on. The controller display will show the actual temperature inside the cabinet.
8. The cooling process will begin to bring the unit to the set temperature. It’s recommended you run the unit for 24 hours to stabilize the operating temperature before using.
2. Remove all contents from the unit.
3. Remove the front grille.
4. Clean the condenser by using a vacuum cleaner to remove loose debris (leaves, dirt, etc.) that may have accumulated inside the grille.

DANGER

Never attempt to repair or perform maintenance on the unit until the main electrical power to the unit has been disconnected!

5. Reinstall the front grille.
6. Clean the interior of the unit using stainless steel cleaner and polish (see page 9).
7. Clean the exterior of the unit using stainless steel cleaner and polish (see page 9).

LED REPLACEMENT (SIGNATURE SERIES) Call your Perlick Factory Authorized Service Center. For the location of the Service Center in your area, contact your selling dealer, inquire via the web at www.perlick.com E-mail us at warrantyserv@perlick.com, or call (800) 558-5592 during normal business hours.

CAUTION

LIGHT BULB REPLACEMENT (C-SERIES, ADA-COMPLIANT & SHALLOW-DEPTH SERIES) To replace a defective or burnt out bulb, remove the glass light cover by pulling out on the cover, unscrew the bulb and replace it with an identical or smaller bulb. The Perlick replacement part number is 67026.

Operating the unit at temperatures lower than those recommended will void the warranty.

Page 8 of the Perlick HC24 user manual — CAUTION
Page 8 · click to enlarge
Page 8

STAINLESS STEEL CARE & CLEANING

contact your cleaner supplier. If your present cleaner contains chlorides, ask your supplier for an alternative. Avoid cleaners containing quaternary salt; it also can attack stainless steel and cause pitting and rusting.

General Stainless steel is a “passive” metal because it contains other metals like chromium, nickel and manganese that stabilize the atoms. Chromium provides an invisible passive film that covers the steel surface, acting as a shield against corrosion. As long as the film is intact and not contaminated, the metal is passive and stainless. If the passive film of stainless steel has been broken, equipment can start to corrode and rust.

Keep food equipment clean. Use alkaline, alkaline chlorinated or non-chloride cleaners at recommended strength. Clean frequently to avoid build-up of hard, stubborn stains. The single most likely cause of damage is chlorides in the water. Remember, adding heat to cleaners that contain chlorides dramatically increases their effect on stainless steel.

Three materials or processes can break down stainless steel’s passive layer and allow corrosion to occur:

If chlorinated cleaners are used, immediately rinse and wipe equipment and supplies dry. The sooner you wipe standing water, especially when it contains cleaning agents, the better. After wiping equipment down, allow it to air dry. Oxygen helps maintain the stainless steel passive film.

  • Mechanical abrasion
  • Deposits and water
  • Chlorides

Mechanical abrasion refers to items that will scratch a steel surface. Steel pads, wire brushes and scrapers are prime examples.

Cleaning the Cabinet Interior/Exterior

NEVER use hydrochloric acid (muriatic acid) on stainless steel. Do not use abrasive cleansers or cloths on any interior or exterior surfaces or removeable parts.

CAUTION

Water comes out of the faucet in varying degrees of hardness. Hard water may leave spots. When allowed to sit, these deposits will break down the passive chromium layer and rust stainless steel. Other deposits from food preparation must be promptly removed with an appropriate cleaning agent.

Glass panels may be cleaned using any standard glass cleaner available on the market.

To clean interior and exterior non-metallic surfaces and removable parts, wash with mild solution of soap and lukewarm water with a little baking soda. Rinse and dry thoroughly. Avoid getting water on the lights, controllers, fan motors and unfinished wood wine rack faces.

Chlorides are found nearly everywhere. They are in water, food and table salt. Household and industrial cleaners are the worst offenders.

Preventing Stainless Steel Rust Use non-abrasive tools to clean stainless steel products. Soft cloths and plastic scouring pads will not harm the steel’s passive layer.

Cleaning the Condenser The condenser (located behind the front grille cover) should be cleaned every three (3) months. Use a soft bristle brush and vacuum to remove dust and lint.

Clean with polish lines. Some stainless steels have visible polishing lines or “grain”. When visible lines are present, always scrub in a motion parallel to the lines. When the grain cannot be seen, polish in a consistent straight pattern and not in a circular motion.

CAUTION

Avoid damaging or crushing the condenser fins or tubing.

Use alkaline, alkaline chlorinated or non-chloride containing cleaners. While many traditional cleaners are loaded with chlorides, the industry is providing an ever- increasing choice of non-chloride cleaners. If you are not sure of chloride content in the cleaner being used,

Page 9 of the Perlick HC24 user manual — STAINLESS STEEL CARE & CLEANING
Page 9 · click to enlarge
Page 9

Recommended Cleaners for Specific Situations

JobCleaning AgentComments Routine cleaningSoap, ammonia, detergentApply with sponge or soft cloth Fingerprints and smearsAreal 20, Lac-O-Nu, Lumin Wash, O-Cedar Cream PolishProvides barrier film to minimize fingerprints. Can be used on all finishes. Rub the surface with a cloth as directed on the package. Stubborn stains and discolorationsAllChem Concentrated Cleaner, Samae, Twinkle, Cameo Copper Cleaners, Grade FFF Italian Pumice Whiting, Steel Bright, Lumin Cleaner, Zud Restoro, Sta-Clean, Highlite Cooper’s Stainless Steel Cleaner or Revere Stainless Steel CleanerApply with a damp sponge or cloth, then rinse with clear water and wipe dry. Old Dutch, Lighthouse Sunbrite, Wyandotte Bab-O, Gold Dust, Sapollo, Bon Ami or CometFor these household cleaners, rub with a damp cloth. They may contain chlorine bleaches so rinse thoroughly after use and wipe dry. Liquid NuSteel or Dubois TempFor these products, rub the surface with a dry cloth using only a small amount of cleanser. Rinse with water and dry. Heat tint or heavy discolorationPenny-Brite, Copper Brite, Paste Nu-Steel, Dubois Temp or TarniteRub onto surface with a dry cloth Bar Keepers Friend, Revere Stainless Steel Cleaner, Allen Polish, Steel Bright Wyandotte Bab-O or ZudWhen using these cleaners, apply with a damp sponge or cloth, rinse thoroughly and wipe dry. Tenacious deposits, rust, discoloration, industrial atmospheric stainsOakite No. 33 Dilac, Texo NY, Flash-Klenz Caddy Cleaner, Turco Scale 4368 or Permag 57Swab and soak with a clean cloth. Let stand for 15 minutes or more according to directions on package, then rinse and wipe dry. Rust dicoloration or corrosion caused by cleaning agents containing hydrochloric (muriatic) acid or chlorine bleach3M Scotch Pad, type A, grade “fine”Clean off the surface soil using cleaning methods above. Then rub discolored or corroded areas lightly with a dry pad. Use of property names is intended only to indicate a type of cleaner and does not constitute an endorsement. Omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on the package. NOTE: Do NOT use steel wool or scouring pads to clean stainless steel.

For Replacement Parts and Accessories

  • Contact your selling dealer
  • Use only genuine Perlick replacement parts and accessories. Genuine Perlick parts and accessories are designed to work correctly with Perlick products and offer superior service life. The use of non-Perlick parts can damage the unit and may void the warranty.
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a>
  • Call 800-558-5592 for factory assistance on planning installation or product information
  • Write to Perlick Corporation, Customer Service Department, 8300 West Good Hope Road, Milwaukee, WI 53223
  • Check the model and serial number of your unit located on the label attached to the inside top of the cabinet. Call your Perlick Factory Authorized Service Center.
  • Email us at warrantyserv@<a href="http://perlick.com" rel="nofollow noopener" target="_blank">perlick.com</a>
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a> or call 800-558-5592.
  • Check the model and serial number of your unit located on the label attached to the inside top of the cabinet.
  • Inquire via the web at <a href="http://www.perlick.com" rel="nofollow noopener" target="_blank">www.perlick.com</a> or call 800558-5592.

For Product Service

Page 10 of the Perlick HC24 user manual — TROUBLESHOOTING
Page 10 · click to enlarge
Page 10

TROUBLESHOOTING

DANGER

If the unit appears to be malfunctioning, read through the OPERATION section of this manual first. If the problem persists, check this troubleshooting section to see if you can refer to the cause and remedy of the problem and resolve it without a service call.

Never attempt to repair or perform maintenance on the unit until the main electrical power to the unit has been disconnected!

ProblemCauseSolution No interior lightBulb is loose• Tighten bulb Bulb is burnt out• Replace bulb LED board is inoperable• Contact Perlick Technical Service at 800-558-5592 Light stays on when door switch is closedManual switch is on• Turn manual switch off Door is not making contact with the door switch• Makre sure the door closes tightly Noisy operationSoft sounds from compressor, fan motor and valves heard• Normal operation “Crackling” sound during defrost• Normal operation LED Controller display is flashing ”P1”*Thermostat probe has failed• Contact Perlick Technical Service at 800-558-5592 LED Controller display is flashing “P2”*Evaporator probe has failed• Contact Perlick Technical Service at 800-558-5592 LED Controller display is flashing “HA”*Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes.• Make sure the door is completely closed. • Check the door gasket seal. Replace if necessary. • Check the condenser and clean it if necessary. • Make sure the louvered plate is unobstructed. If surrounding ambient temperature has recently changed dramatically, the compartment may be afefcted. • Make sure the interior light is of.f • Warm product was recently placed in the cabinet. Wait 24 hours for the product to chill and then recheck the temperature. LED Controller display is flashing “LA”*Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes.• Make sure the door is completely closed. • Check the door gasket seal. Replace if necessary. • If the surrounding ambient temperature has recently changed dramatically, the compartment temperature may be afefcted. Unit is not runningNo power is going to the unit.• Home circuit breaker was tripped. Reset the circuit breaker. • ON/OFF keypad is turned of.f Turn it on. • If it is a Dual-Zone model, check the DualZone power switch (see page 4). Condenser is dirty.• Clean the condenser

* Applies to Signature Series models only

Page 11 of the Perlick HC24 user manual — TROUBLESHOOTING
Page 11 · click to enlarge
Page 11
ProblemCauseSolution Compartments are warmer than usualControl preset is set to warm• Lower the setpoint temperature. Refer to changing the set point for the specific model Light is staying on• Turn the manual light switch of.f Condenser is dirty or obstructed• Clean the condenser and clear obstruction. The door is open or has been opened more frequently lately.• Wait 24 hours and recheck the temperature. Internal louvers and/or the fan guard is obstructed.• Reset the preset temperature if necessary – refer to page 5 and 6 of this guide. • Make sure the louvers and/or the fan are not obstructed. Warm product product was recently placed in the cabinet.• Wait 24 hours for product to chill, then recheck the temperature. System runs for a long period of time.Condenser is dirty or obstructed.• Clean the condenser and clear the obstruction. Door was kept open for a long time or was opened more frequently, or warm product was recently placed in the cabinet.• Wait 24 hours and recheck temperature. Hot day and warm room temperature• Normal for the system to run more frequently. Condensation forms inside the compartmentsHigh humidity and/or frequent door opening• Normal operation Door is not closing and sealing properly• Make sure the door is closing properly. Check the door seal and replace if necessary. • If condensation persists, contact Perlick Technical Service at 800-558-5592
Page 12 of the Perlick HC24 user manual — TROUBLESHOOTING
Page 12 · click to enlarge
Page 12

Form No. Z2344 Rev. 04.01.2014

Quality & Innovation · that inspires

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No interior lightBulb is loose• Tighten bulb p.10
No interior lightBulb is burnt out• Replace bulb p.10
No interior lightLED board is inoperable• Contact Perlick Technical Service at 800-558-5592 p.10
Light stays on when door switch is closedManual switch is on• Turn manual switch off p.10
Light stays on when door switch is closedDoor is not making contact with the door switch• Makre sure the door closes tightly p.10
Noisy operationSoft sounds from compressor, fan motor and valves heard• Normal operation p.10
Noisy operation“Crackling” sound during defrost• Normal operation p.10
LED Controller display is flashing ”P1”*Thermostat probe has failed• Contact Perlick Technical Service at 800-558-5592 p.10
LED Controller display is flashing “P2”*Evaporator probe has failed• Contact Perlick Technical Service at 800-558-5592 p.10
LED Controller display is flashing “HA”*Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes.• Make sure the door is completely closed. • Check the door gasket seal. Replace if necessary. • Check the condenser and clean it if necessary. • Make sure the louvered plate is unobstructed. If surrounding ambient temperature has recently changed dramatically, the compartment may be afefcted. • Make sure the interior light is of.f • Warm product was recently placed in the cabinet. Wait 24 hours for the product to chill and then recheck the temperature. p.10
LED Controller display is flashing “LA”*Internal compartment has exceeded the low temperature alarm preset value for over 30 minutes.• Make sure the door is completely closed. • Check the door gasket seal. Replace if necessary. • If the surrounding ambient temperature has recently changed dramatically, the compartment temperature may be afefcted. p.10
Unit is not runningNo power is going to the unit.• Home circuit breaker was tripped. Reset the circuit breaker. • ON/OFF keypad is turned of.f Turn it on. • If it is a Dual-Zone model, check the Dual- Zone power switch (see page 4). p.10
Unit is not runningCondenser is dirty.• Clean the condenser p.10
Compartments are warmer than usualControl preset is set to warm• Lower the setpoint temperature. Refer to changing the set point for the specific model p.11
Compartments are warmer than usualLight is staying on• Turn the manual light switch of.f p.11
Compartments are warmer than usualCondenser is dirty or obstructed• Clean the condenser and clear obstruction. p.11
Compartments are warmer than usualThe door is open or has been opened more frequently lately.• Wait 24 hours and recheck the temperature. p.11
Compartments are warmer than usualInternal louvers and/or the fan guard is obstructed.• Reset the preset temperature if necessary – refer to page 5 and 6 of this guide. • Make sure the louvers and/or the fan are not obstructed. p.11
Compartments are warmer than usualWarm product product was recently placed in the cabinet.• Wait 24 hours for product to chill, then recheck the temperature. p.11
System runs for a long period of time.Condenser is dirty or obstructed.• Clean the condenser and clear the obstruction. p.11
System runs for a long period of time.Door was kept open for a long time or was opened more frequently, or warm product was recently placed in the cabinet.• Wait 24 hours and recheck temperature. p.11
System runs for a long period of time.Hot day and warm room temperature• Normal for the system to run more frequently. p.11
Condensation forms inside the compartmentsHigh humidity and/or frequent door opening• Normal operation p.11
Condensation forms inside the compartmentsDoor is not closing and sealing properly• Make sure the door is closing properly. Check the door seal and replace if necessary. • If condensation persists, contact Perlick Technical Service at 800-558-5592 p.11

Ask about the Perlick HC24

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick HC24

Be the first to ask — other owners or our team will answer.

Original document

Perlick HC24 manual PDF

12 pages·1.2 MB·Refrigerator·PDF
Click any page above to open it here
Page 1 / …
100%