MODEL 1058 VDSL Modem

Part# 07M1058-A Doc# 058091UA Revised 10/12/01
An ISO-9001Certified · Company

1.0 Warranty Information 3 1.1 Radio and TV Interference 3 1.2 CE Notice 4 1.3 Service 4
2.0 General Information 5 2.1 Features 5 2.2 Description 5
3.0 Installation 7 3.1 Connecting the Twisted-Pair Line Interface 7 3.2 Connecting the 10/100Base-T Ethernet Interface 9
Connecting the 10/100Base-T Ethernet Port to a Hub 9 Connecting the 10/100Base-T Ethernet Port to a PC (DTE) 10 3.3 Connecting the POTS/ISDN line 10 3.4 Connecting Power 11
4.0 Operation 12 4.1 Power Up 12 4.2 Front Panel LED Status Monitors 12
A Specifications 14 A.1 LAN Connection 14 A.2 Transmission Line 14 A.3 VDSL Line Rate 14 A.4 Actual Data Rate 14 A.5 VDSL Distance 14 A.6 VDSL Surge Suppressor 14 A.7 LED Status Indicators 14 A.8 Power Supply 14 A.9 Temperature Range 14 A.10 Humidity 14 A.11 Dimensions 14
B Model 1058 Series Factory Replacement Parts and Accessories 15
C Model 1058 Series Interface Pin Assignment 16 C.1 10/100Base-T Interface: 16 RJ-45 16 C.2 VDSL Interface: 16
RJ-45 16 Terminal Block 16 C.3 POTS/ISDN Interface: 16

Patton Electronics warrants all Model 1058 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics spe- cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
The Model 1058 generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufac- turer’s instructions-may cause interference to radio and television recep- tion. The Model 1058 has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Sub- part B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular instal- lation. If the Model 1058 does cause interference to radio or television reception, which can be determined by disconnecting the unit , the user is encouraged to try to correct the interference by one or more of the fol- lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Cer- tificate of Compliance is available by contacting Technical Support.
This device is not intended to be connected to the public telephone network.
All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi- als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.
The Patton Electronics Model 1058/CO* and 1058/CP VDSL* modems provide high-speed LAN connections between peered Ethernet LANs, remote PC’s, or any other network enabled 10/100Base-T device.
Operating in pairs with a Model 1058/CO (central office) located at one end of the LAN extension and a Model 1058/CP (customer premise) at the other end, these units can automatically forward LAN broadcasts, multi- casts, and frames across a 2-wire twisted pair link. The data is passed transparently (that is, unmodified) through the 1058s. What’s more, the 1058s automatically add and delete MAC addresses, only passing packets across the VDSL link that are meant for the remote peered LAN.
* Only Models 1058DV/CO and 1058DV/CP have POTS/ISDN split- ters on board.


Figure 1. Typical application
The 1058DV/CO and 1058DV/CP work together to create a transparent extension between two peered Ethernet LANs. POTS/ISDN calls can be made over the VDSL link without interfering with the data. Figure 1 shows a typical point-to-point application.

Because the Model 1058 requires no configuration, it can be installed and made operational quickly. Installation takes place as follows:
“Connecting the Twisted-Pair Line Interface” on page 7)
the 10/100Base-T Ethernet Interface” on page 9).

Figure 2. Model 1058 standalone rear panel
The Model 1058 supports communication between two peer Ethernet LAN sites over a distance of up to 4,652 ft (1,418 m) over 24 AWG (0.5 mm) twisted-pair wire.

Follow the steps below to connect the Model 1058 VDSL Interfaces.
Note The Model 1058 units work in pairs. One of the units must be a Model 1058/CO (Central Office), and the other unit must be a Model 1058/CP (Customer Premise). It does not matter which end is the 1058/CO and which is the 1058/CP. The link is always initiated by the 1058/CP. As long as the 1058/CO is powered on, the 1058/CP can establish a link by being powered on or by hav- ing its power reset.
together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
on the VDSL interface, an RJ-45 or a terminal block. These VDSL interfaces are a two-wire interface. Observe the signal/pin relation- ships on the Model 1058's VDSL interface jacks.
The RJ-45 connector on the Model 1058's twisted pair interface is polar- ity insensitive and is wired for a two-wire interface. The signal/pin rela- tionship is shown in Figure 3.
1 2 3 4 5 6 7 8
Figure 3. Model 1058 (RJ-45) twisted pair line interface.
The terminal block connector on the Model 1058's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationships is shown in Figure 4.


Figure 4. Model 1058D (Terminal Block) twisted pair line interface.
The shielded RJ-45 port labeled Ethernet is the 10/100Base-T interface. This port is designed to connect directly to a 10/100Base-T network. Figure 5 shows the signal/pin relationships on this interface. You may connect this port to another Ethernet device via a Type 4 or Type 5 cable that is up to 328 ft long.

Figure 5. Model 1058 10/100Base-T RJ-45 Connector Pinout.
Connecting the 10/100Base-T Ethernet Port to a Hub
The Model 1058 10/100Base-T interface is configured as DTE (Data Ter- minal Equipment), just like a 10/100Base-T network interface card in a PC. Therefore, it "expects" to connect to a 10/100Base-T Hub using a

straight-through RJ-45 cable. Figure 6 diagrams the cable wiring for con- necting the Model 1058 to a 10/100Base-T hub.
1058 10/100Base-T Port RJ-45 Pin No.
10/100Base-T Hub RJ-45 Pin No.
2 (TX-)---------------------------------------------------2 (RX-)
3 (RX+)--------------------------------------------------3 (TX+)
6 (RX-)---------------------------------------------------6 (TX-)
Figure 6. Wiring diagram for connecting the Model 1058 to a 10/100Base-T hub
Connecting the 10/100Base-T Ethernet Port to a PC (DTE)
The Model 1058 10/100Base-T interface is configured as DTE (Data Ter- minal Equipment). If you wish to connect the 1058 to another DTE devices such as 10/100Base-T network interface card in a PC (or 1058s in a back-to-back arrangement), you must construct a 10/100Base-T crossover cable as shown in Figure 7.
1058 10/100Base-T Port RJ-45 Pin No.
10/100Base-T DTE RJ-45 Pin No.
2 (TX-) 2 (TX-)
3 (RX+) 3 (RX+)
6 (RX-) 6 (RX-)
Figure 7. 10/100Base-T crossover cable
The RJ-45 port labeled “POTS/ISDN” is the POTS/ISDN interface. A tele- phone or an ISDN device may be connected to this port and carried over the VDSL line. The units do not need power for the POTS interface to

work. The RJ-45 connector in the model 1058’s POTS/ISDN interface is wired as shown in Figure 8.
1 2 3 4 5 6 7 8
Figure 8. Model 1058DV (RJ-45) POTS/ISDN interface
An external AC or DC power supply is available separately. This connec- tion is made via the barrel jack on the rear panel of the Model 1058. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 1058) must meet the following requirements; DC power supplied must be regulated +5VDC ±5%, 1.0A minimum. Center pin is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
The Model 1058 does not have a power switch, so it powers up as soon as it is plugged in.

Once the Model 1058s are properly installed, they should operate trans- parently. No user settings required. This section describes reading the LED status monitors.
Before applying power to the Model 1058, please review section 3.4, “Connecting Power” on page 11 to verify that the unit is connected to the appropriate power source.
The Model 1058 features five front panel LEDs that monitor power, the Ethernet signals, and the VDSL Connection. Figure 9 shows the front panel location of each LED. Table 1 on page 13 describes the LED func- tions.


Power Solid GREEN to indicate the unit is powered on. VDSL Link (Active Green) Solid green (ON) to indicate that the end-to-end VDSL link between the Model 1058s is established. The VDSL LED is OFF when the link is down. VDSL Error (Active Red) Flashes Red to indicate errors have occurred on the VDSL link. Ethernet Link (Active Green) Solid Green indicates that 10/ 100Base-T Ethernet link has been established. Ethernet Activity (Active Yellow) Flashes yellow to indicate Ethernet activity on the Model 1058's 10/100Base-T Ethernet port.
LED Description

A.1 LAN CONNECTION
Two-wire unconditioned twisted pair
12.5 Mbps, symmetric upstream/downstream.
10 Mbps, symmetric upstream/downstream.
4,000 ft (1,219 m)
Gas tube with maximum current surge: 20 kA (8120 µs)
External AC and DC options
0–50°C
A.10 HUMIDITY
Up to 90% non-condensing
1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)

APPENDIX B MODEL 1058 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES
Patton Model # Description
Base Models 1058D/CO CO VDSL Modem, data only, no power supply 1058D/CP CP VDSL Modem, data only, no power supply 1058D-2PK VDSL MODEM Kit: includes one central office (CO) and one customer premise (CP) Model 1058, data only, no power supply 1058DV/CO CO VDSL Modem, voice & data, no power supply 1058DV/CP CP VDSL Modem, voice & data, no power supply 1058DV-2PK VDSL MODEM Kit: includes one central office (CO) and one customer premise (CP) Model 1058, voice & data, no power supply 07M1058 User Manual Power Supplies 08055DCUI
100-240VAC (+5V reg. DC/2A) Universal Input Adapter.
120 VAC (+5V reg. DC/1A) Input Adapter 12V-PSM 12 VDC Input Adapter 24V-PSM 24 VDC Input Adapter 48V-PSM 48 VDC Input Adapter Power Cords* 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord
*Only required with optional UI power supply (08055DCUI)
08055-120-5-1

C.1 10/100BASE-T INTERFACE:
RJ-45
RJ-45
See Figure 4 on page 9.
RJ-45
Copyright © 2001 Patton Electronics Company
All Rights Reserved.
Terminal Block