MODEL 574, 576, 578, 584, 586, 588 Standalone Hub 100Base-T (CAT-5) Surge Protectors

USER MANUA L

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

Page 2 of the Patton electronic 586 user manual — 2.2 DESCRIPTION
Page 2 · click to enlarge
Page 2

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.

1.2 CE NOTICE

Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your 57x/58x. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

All warranty and nonwarranty repairs must be returned freight pre- paid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping contain- er. This number may be obtained from Patton Electronics Technical Service: (301) 975-1007, http://www.patton.com; support@patton.com.

1.1 SERVICE

Patton Electronics warrants all Model 57x/58x components to be free from defects, and will—at our option—repair or replace the prod- uct should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.0 WARRANTY INFORMATION

Models 57x/58x support a wide range of balanced interfaces from RS-422 to 100Base-T4. Highlights include a low insertion loss (less than 0.4dB at 100MHz) and minimal near end cross talk (better than -40 dB at all frequencies up to 100 MHz). Grounding is accomplished via a braided ground strap that provides a separate unit-rack connec- tion. The customer is responsible for ensuring a proper rack to earth ground connection. For proper grounding, the resistance from the sup- plied ground lug to the rack frame ground should be less han 2.5 mil- liohms. Contact Technical Support (see Section 1.1 Service) if further details are needed for this measurement.

The Patton Model 57x and 58x Series Surge Protectors pro- vide effective surge protection for devices operating in Category-5 Cabling Systems. The Model 57x/58x is specifically designed for point-of-use installation; the Model 57x/58x is designed to be installed at the building entrance. Both models use a multi-stage Silicon Avalanche Diode circuit, and will continue functioning while handling the appropriate IEC 801.5 surges applicable to their use (see the tables in Appendix B). Both the 57x/58x will additionally protect against surges up to and exceeding 2kV/1kA in fail-safe mode.

Devices that connect to Category-5 cabling systems are routinely threatened by unwanted electrical energy (lightning, AC power induc- tion, ESD and more). Higher speed devices–such as those operating at 100 Mbps–are especially vulnerable to the effects of these hazards, which can include data loss and hardware damage.

2.2 DESCRIPTION

2.1 FEATURES

2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Year parts and labor. If any questions or problems arise during installation or use of this product, please contact Patton Electronics Customer Service at (301) 975-1007.

  • Made in the U.S. A.
  • Easy to install
  • Shunts surges directly to chassis ground
  • N.E.X.T. better than -40 dB at 100 MHz
  • EIA/TIA TSB-40A Category 5 Compliant
  • Can support applications having 2, 4, 6 or 8 wire per cable
  • Operation at Speeds up to 100 Mbps
  • Multi-level surge protection
  • Optional 4, 6, or 8 port surge protection hubs
Page 3 of the Patton electronic 586 user manual — 3.1.2 BARRIER APPLICATION (MODEL 58x)
Page 3 · click to enlarge
Page 3

The Model 57x is designed for installation on LAN equipment in a typical office environment, as in Figure 1, below. For best results, the Model 57x should be connected as close as possible to the communi- cation port of the device to be protected.

3.1.1 POINT-OF-USE APPLICATION (MODEL 57x)

Both Models 57x and 58x protect all eight pins on the modular RJ-45 Cat-5 interface, and work in environments with data rates up to 100 Mbps. The following descriptions will give you a general guideline for installing the units in your Cat-5 environment.

3.1 PRODUCT APPLICATIONS

Model’s 57x and 58x surge protectors are easy to install and are designed to operate transparently to your network. This section describes cohnnection procedures for both models.

Figure 1. Model 57x58x Point of Use Application

Model 570 or 580

Model 570 or 580

Model 57x or 58x

3.0 INSTALLATION

Model 570 or 580

To Other Building or Wall

The Model 58x is also well suited for use in severe lightning areas, heavy industrial environments, and situations where heavy machinery is in the direct vicinity of sensitive LAN equipment and cabling. Figure 2 (below) shows a typical application for the Model 58x. For best results, the braided grounding strap(s) on the Model 58x should be attached to the grounded metal frame of the device being protected. When installation is made at a barrier, such as an external wall, the braided strap must be connected to a nearby electrical ground. If a nearby electrical ground cannot be located, contact Patton Technical Support (See Section 1.1).

The Model 58x is a more robust protector than the Model 57x, and is designed for use as a barrier protector on LAN equipment in campus networks. Applications include: cable runs between buildings; cable runs between floors on multi-story structures; and as a higher capacity replacement for the Model 57x.

Also, the flat braided grounding wire(s) on the Model 57x should be attached to the grounded metal frame of the device being protect- ed. If it is not possible to attach it to the equipment being protected, contact Patton Technical Support (See Section 1.1).

3.1.2 BARRIER APPLICATION (MODEL 58x)

Figure 2. Barrier Application for 58x

Model 57x or 58x

To Other Building or Wall

Show 13 more labels / short text on this page
Typical 100Base-T Application · Typical RS-422/485 Application · Workstation · Workstation · 57x or 58x · Local Hub · Electrical Panel · Exterior Wall · Controller · Workstation · Model 580 · Electrical Panel · Exterior Wall
Page 4 of the Patton electronic 586 user manual — 3.2.2 Connecting the Model 58x at a Barrier (Wall, Building, Entrance, etc.)
Page 4 · click to enlarge
Page 4

Caution: Surge energy may run both directions on the ground strap. To provide the best protection, it is essential that the sup- plied ground strap on the Model 57x/58x is connected to the chas- sis ground of the protected device. Do Not lengthen the ground strap or connect to a ground other than chassis ground unless instructed to do so by Patton Technical Support.

4. Connect the braided ground strap directly to chassis ground connection you have located (see Figure 3, above). The best way to make this ground connection is to attach the braided metal strap using a hex nut or screw on your protected device.
3. Locate a metal chassis ground. This is often a hex screw on a Dshell or an AUI connector. Sometimes, a metal backpanel is attached with screws, one of which can be used with chassis grounding. If you cannot locate a chassis ground equipment on your equipment, contact Patton Technical Support (See Section 1.1) to discuss an alternate grounding solution.
2. Install the surge protector between the incoming UTP line and the protected equipment, as in Figure 3, below. This installation requires a straight through Cat-5 patch cable with modular RJ-45 male connectors . Use shortest length possible.
1. Turn off equipment power and disconnect the existing connection between the UTP cable and the equipment’s I/O port.

3.2.1 Connecting the Model 57x or 58x to an I/O Port

In order to operate as designed, the Model 57x and 58x must be connected correctly to your Cat-5 network. For the safest installation, please read all the instructions below and follow them very carefully.

3.2 INSTALLATION PROCEDURES

Cat. 5 patch cable to pro- tected equipment

Figure 3. Installation of Model 57x /58x Surge Protectors.

Cat. 5 input from network

Connection to chassis ground

3.2.2 Connecting the Model 58x at a Barrier (Wall, Building, Entrance, etc.)

4. Connect the rack structure frame directly to the earth ground if it is not already connected. The best way to make this ground con- nection is to attach a thick braided metal strap earth ground to a metal panel, a wall plate screw or an electrical panel or subpanel, using a hex nut or ground screw. Pay close attention to the impor- tant note in Figure 4. If you cannot locate a nearby electrical ground, contact Patton Electronics Technical Service (see Section 1.1)

3. Connect the ground braid(s) to the rack frame according to Figure 4 connected to earth ground. Do not lengthen the ground strap or section describes connection procedures for both models.
2. Install the Model 58x between the UTP line and the jack. This installation requires a straight through Cat-5 patch cable with modular RJ-45 male connectors.
1. Disconnect the UTP cable from the wall jack or patch panel jack.

Caution: Surge energy may run both directions on the ground strap. To provide the best protection, it is essential that the sup- plied ground strap on the 57x/58x is connected to the chassis ground of the protected device. Do not lengthen the ground strap or connect to a ground other than a chassis ground unless instructed to do so by Patton Technical Support.

Page 5 of the Patton electronic 586 user manual — Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Page 5 · click to enlarge
Page 5

Flame Retardance : Plastic cases meet UL 94-V0 standard

Standard Temperatures : 0 - 50 0 C/32 - 122 0 F

Actual Panel Dimensions: 3.47” x 19.0” x 1.1”

PC Board Dimensions: 7.0” x 3.0”

Grounding: External ground strap provides separate unit-ground to chassis-ground contact

Series Resistance: Less than 400 milliohms

Group Delay: None, 1 MHz to 100 MHz

Return Loss: Better than 14 dB on both models

Insertion Loss: Less than 0.4 dB (including connector) at all frequencies

DC Clamping Voltages: Common Mode to Gnd, 7.5 V (each line) @ 50 mA; Differential mode, 8.1 V (per pair) @ 50 mA

Surge Rating: IEC 801.5 Standard Level

Surge Clamping Voltages: Model 57x: 13 V max with 1 KV Input; Model 58x: 15 V max with 2 KV Input

NEXT Loss (worst pair): Better than -40 dB at 100 MHz

Characteristic Impedance: 100 Ohms

Response Time: Clamped to 13V after 0.1µS

Connectors: RJ-45 Female

Environment: Category-5 Interfaces that utilize the RJ-45 connector, including RS-422, 423, 10Base- T, Token Ring, Fast Ethernet, 100Base-T, 100Base-T4 and ATM

APPENDIX A SPECIFICATIONS

IEC 801-5 Threat Levels as a Function of Class ClassSym. Lines Coupling Mode Line-GND, Zs=42 Ohms 11.0 kV 24 A 21.0 kV 24 A 32.0 kV 48 A 4(n/a) (n/a) 54.0 Kv 95 A Wave Forms(1.2 x 50 µs) (1.2 x 50 µs)

*Note: All test results are for the Model 57x/58x alone, not including any external patch cables that are connected to the unit.

Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)

Figure B-1. IEC Threat Levels as a Function of Class.

IEC 801-5 Threat Levels as a Function of Class

1 1.0 kV 24 A 2 1.0 kV 24 A 3 2.0 kV 48 A 4 (n/a) (n/a) 5 4.0 Kv 95 A Wave (1.2 x 50 µs) Forms (1.2 x 50 µs)

Sym. Lines Coupling Mode

Class · Line-GND, Zs=42 Ohms

Page 6 of the Patton electronic 586 user manual — TSB-40A COMPLIANCE TESTING RESULTS TYPICAL NEAR-END CROSSTALK MEASUREMENT
Page 6 · click to enlarge
Page 6
APPENDIX C EIA/TIA TSB-40A COMPLIANCE The Model 57x/58x series surge protectors have been designed to conform to stringent EIA/TIA TSB-40 standards as required for all Category-5 connecting hardware. These standards specify the capacitance and near end cross-talk (N.E.X.T) to insure proper operation of ALL connected equipment. Specific test results are shown in the tables on the following pages*. TSB-40A COMPLIANCE TESTING RESULTS TYPICAL NEAR-END CROSSTALK MEASUREMENT SOURCE/VICTIM PAIRS FREQ MHz1-2/3-6 dB1-2/4-5 dB1-2/7-8 dB3-6/4-5 dB3-6/7-8 dB4-5/7-8 dBSPEC dB 182.085.085.078.084.082.0>65 474.077.085.068.073.071.0>65 869.071.083.062.867.064.062 1067.069.083.061.066.063.060 1663.066.079.056.061.059.056 2065.564.078.057.066.056.054 2562.062.077.053.058.056.052 31.2556.162.075.552.054.653.050 62.546.056.074.044.546.047.044 10045.048.057.040.542.049.040 Figure C-1. N.E.X.T. measurements for Patton Model 57x SOURCE/VICTIM PAIRS FREQ MHz1-2/3-6 dB1-2/4-5 dB1-2/7-8 dB3-6/4-5 dB3-6/7-8 dB4-5/7-8 dBSPEC dB 177.085.085.079.083.081.0>65 470.076.085.068.073.070.0>65 867.070.085.062.167.064.062 1067.0 68.085.061.066.062.060 1662.0 65.083.057.061.058.056 2069.0 65.073.058.063.056.054 2559.0 62.072.053.258.055.052 31.2557.061.081.051.055.053.050 62.551.557.068.045.046.048.044 10044.0 45.054.042.041.449.040 Figure C-2. N.E.X.T. measurements for Patton Model 58x *Note: All test results are for the Model 57x/58x alone, not including any external patch cables that are connected to the unit. 9

SOURCE/VICTIM PAIRS FREQ 1-2/3-6 1-2/4-5 1-2/7-8 3-6/4-5 3-6/7-8 4-5/7-8 SPEC MHz dB

APPENDIX C (continued) TSB-40A COMPLIANCE TESTING RESULTS TYPICAL ATTENUATION MEASUREMENT Freq MHzPins: 1-2 dBPins: 3-6 dBPins: 4-5 dBPins:7-8 dBSpec dB 10.00.00.00.10.1 40.10.10.10.00.1 80.00.10.10.10.1 100.00.00.10.00.1 160.10.10.10.00.2 200.10.10.20.00.2 250.00.00.10.00.2 35.250.00.10.20.00.2 62.50.20.10.30.00.3 1000.40.30.40.30.4 Figure C-3. Attenuation Measurements for Patton Model 57x Freq MHzPins: 1-2 dBPins: 3-6 dBPins: 4-5 dBPins:7-8 dBSpec dB 10.10.00.10.10.1 40.10.10.00.10.1 80.00.10.00.10.1 100.10.10.10.10.1 160.10.10.10.10.2 200.10.20.00.20.2 250.00.10.10.10.2 35.250.00.10.00.10.2 62.50.10.20.10.20.3 1000.40.30.40.30.4 Figure C-4. Attenuation measurements for Patton Model 58x 10

TSB-40A COMPLIANCE TESTING RESULTS TYPICAL NEAR-END CROSSTALK MEASUREMENT

Figure C-3. Attenuation Measurements for Patton Model 57x

Page 7 of the Patton electronic 586 user manual — Appendix C (continued) TSB-40A Compliance Testing Results TYPICAL INSERTION LOSS MEASUREMENT
Page 7 · click to enlarge
Page 7
APPENDIX C (continued) TSB-40A COMPLIANCE TESTING RESULTS TYPICAL RETURN LOSS MEASUREMENT Freq MHzPins: 1-2 dBPins: 3-6 dBPins: 4-5 dBPins:7-8 dBSpec dB 134.028.028.029.023 438.038.045.043.823 839.041.042.042.023 1038.041.039.039.523 1634.035.033.033.023 2033.733.031.031.623 2531.030.034.030.014 31.2528.127.028.027.814 62.521.022.022.022.014 10017.021.018.217.814 Figure C-5. Return Loss Measurements for Patton Model 57x Freq MHzPins: 1-2 dBPins: 3-6 dBPins: 4-5 dBPins:7-8 dBSpec dB 128.028.029.030.023 438.038.447.044.523 839.043.841.041.223 1038.044.038.038.723 1635.038.030.033.423 2033.034.031.031.023 2531.031.029.028.314 31.2529.028.027.028.014 62.521.822.021.021.014 10017.219.316.717.314 Figure C-6. Return Loss measurements for Patton Model 58x 11

Figure C-5. Return Loss Measurements for Patton Model 57x

Pin Number:DC Resistance Milliohms 1180 2190 3180 4190 5180 6120 7190 8180 Figure C-7. Patton Model 57x Series Insertion Loss Measurement
Pin Number:DC Resistance Milliohms 1180 2180 3180 4190 5190 6120 7180 8160 Figure C-8.Patton Model 58x Series Insertion Loss Measurement

Figure C-7. Patton Model 57x Series Insertion Loss Measurement

Appendix C (continued) TSB-40A Compliance Testing Results TYPICAL INSERTION LOSS MEASUREMENT

Pin NumberDC Resistance Milliohms
Pin NumberDC Resistance Milliohms

1 180 2 190 3 180 4 190 5 180 6 120 7 190 8 180

Page 8 of the Patton electronic 586 user manual — Burton A.Patton Executive Vice President
Page 8 · click to enlarge
Page 8

P.S. Please tell us where you purchased this product

Please contact us and let us know how we may provide you with the answers to your needs.

We are committed to a quality product at a quality price. Patton Electronics is BABT and ISO 9001 certified. We meet and exceed the highest standards in the industry (CE, UL, etc.).

We would like to hear from you. Please contact us in any of the fol- lowing ways to tell us how you like this product and how we can meet your product needs today and in the future.

We manufacture one of the widest selections of data communica- tions products in the world including CSU/DSU's, network termination units, powered and self-powered short range modems, fiber optic modems, interface converters, baluns, electronic data switches, data-line surge protectors, multi- plexers, transceivers, hubs, print servers and much more. We produce these products at our Gaithersburg, MD, USA, facility, and can custom manufacture products for your unique needs.

Thank you for purchasing Patton Electronics products! We do appreciate your business. I trust that you find this user manual helpful.

Dear Valued Customer,

Thank you.

Web: http:www.patton.com Sales E-mail: sales@patton.com Support E-mail: support@patton.com Phone - Sales (301) 975-1000 Phone - Support (301) 975-1007 Fax: (301) 869-9293 Mail: Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

Burton A.Patton Executive Vice President

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 586

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 586

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 586 manual PDF

8 pages·45 KB·Surge Protector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…